1. Evaporator m Mounting kit Cab command In the event of any abnormality missing damaged part or part number etc fill in the form Advance Warning DOA Claim Carrier Transicold Europe 03 09 07 Viento Installation Rev 5 56 Operation amp Service Manual VIENTO Installation Preparation before installation Vehicle partition m ake care not to obstruct the air intakes on the evaporator section and the ventilation ducts I For any mobile partition installation contact our Technical Department or refer to the following chart MODELS Evaporator X Y y MXS600 MXS600 Viento 200 ETA 850 MXS850 ane I Viento 300 150 mm j MXL ea i MXS 1100 Viento 350 1000 mm MXL 1100 Carrier Transicold Europe 03 09 07 Viento Installation Rev 6 56 Operation amp Service Manual VIENTO Installation Box preparation Drilling RECOMMENDATIONS Before box preparation and unit installation commences protect the vehicle roof and the refrigeration box floor cover cardboard There are 3 possibilities to fit the unit Roof top Nosemount Roof cut mounting Carrier Transicold Europe 03 09 07 Viento Installation Rev 7 56 Operation amp Service Manual VIENTO Installation Box preparation Drilling Roof top and cut mounting 1 Present the drilling template not supplied refer to the bodybuilder drawing 2 Mark out the 4 fixing holes and the
2. 1 manifold gauges 4 connections 1 vacuumeter To check gas leak 1 Install manifold gauges on the compressor side 2 Connect the vacuum pump to the manifold gauges O Start the vacuum pump and vacuum for 15 mn to remove the air in the circuit After 15mn stop the vacuum pump Connect the nitrogen to the manifold gauges Put 15 bar 219 psi in the circuit Use bubbles water on all refrigeration fittings 0 N O Ol A No bubbles formation means that the circuit is tight Carrier Transicold Europe 03 09 07 Viento Installation Rev 49 56 Operation amp Service Manual VIENTO Installation Commissioning Unit vacuum ere To vacuum the circuit 5000 a 1 Remove the nitrogen 4000 2 Start the vacuum pump 3500 3 Apply Triple evacuation process eee refer to refrigeration training module 500 4 Stop the vacuum pump 2000 5 Check if vacuum is complete with vacuumeter TH refer to refrigeration training module 1500 1000 500 0 Carrier Transicold Europe 03 09 07 Viento Installation Rev 50 56 Operation amp Service Manual VIENTO Installation Commissioning Refrigerant charge A REQUIREMENT 1 manifold gauges 4 connections a 1 refrigerant cylinder 1 scale minimum precision requested 5 After vacuum charge the circuit 1 Install the manifold gauges on Free Schrader fitting located inside the condenser on the high pressure line 2 Place refrigerant cy
3. Maintain all cables with plastic tie wraps Carrier Transicold Europe 03 09 07 Viento Installation Rev 1145 56 Operation amp Service Manual VIENTO Installation Battery amp ignition key harness fitting 1 Route the ignition cable to the vehicle fuse box 2 Connect the white wire onto the fuse holder supplied in the mounting kit 1A 3 Refer to the corresponding mounting kit instruction to connect the 12Vdc ignition live Install the 80 amps fuse holder as closed as possible from the 12 Vdc battery Cut the battery harness to the required length Carrier Transicold Europe 03 09 07 Viento Installation Rev 46 56 Operation amp Service Manual VIENTO Installation Battery amp ignition key harness fitting 4 Connect the fuse 5 Put grease on the fuse holder connections 6 Connect the battery red Crimp the terminal with adapted crimping tool Carrier Transicold Europe 03 09 07 Viento Installation Rev 47 56 Operation amp Service Manual VIENTO Installation Battery harness fitting 7 Install the 80 amps fuse in the fuse holder 8 Install protection cap on the fuse 9 Connect unit ground to the vehicle chassis 10 Re connect the ground of the vehicle battery Carrier Transicold Europe 03 09 07 Viento Installation Rev 48 56 Operation amp Service Manual VIENTO Installation Commissioning Leak checking A REQUIREMENT 1 vacuum pump
4. ring is missing put a new one in place 4 hoses have to be connected on the unit m Oil return line High pressure line m Liquid line m Hot gas line Carrier Transicold Europe 03 09 07 Viento Installation Rev 31 56 Operation amp Service Manual VIENTO Installation Unit connection Refrigeration hoses 4 Connect the OIL RETURN HOSE to the oil separator lower fitting to the compressor 5 Connect the HIGH PRESSURE LINE to the oil separator upper fitting to the compressor Carrier Transicold Europe 03 09 07 Viento Installation Rev 32 56 Operation amp Service Manual VIENTO Installation Unit connection Refrigeration hoses 6 Remove the Hot Gas valve HGV solenoid to connect the HOT GAS LINE hose easily 7 Connect the HOT GAS LINE fitting to the Hot Gas valve 8 Re install the Hot Gas valve solenoid 9 9 Connect the LIQUID LINE HOSE to the filter drier A RECOMMENDATIONS 45 fitting recommended if lateral outlet needed GENERALY use the appropriate fitting depending on the installation Carrier Transicold Europe 03 09 07 Viento Installation Rev 33 56 Operation amp Service Manual VIENTO Installation Unit connection Refrigeration hoses 10 Attach regularly all hoses harnesses with plastic tie wraps Carrier Transicold Europe 03 09 07 Viento Installation Rev 34 56 Operation amp Service Manual VIENTO Installation Evaporator connection
5. NTO Installation Cab command harness fitting NOTE For cab command harness fitting refer to the vehicle mounting kit instructions 1 Route the cab command harness to the vehicle dashboard A RECOMMENDATIONS Protect or move the harness away from metallic corners of the chassis m Avoid connecting the harness to or in contact with heating source m Avoid connecting the harness to parts that may cause vibrations 03 09 07 Viento Installation Rev 40 56 Carrier Transicold Europe Operation amp Service Manual VIENTO Installation Cab command harness fitting 2 Fit the cab command in specified location A RECOMMENDATIONS Take care not to pierce any harness or hoses within the dashboard a l the cab command is built into the dashboard fit it as far as possible from the heating ducts m Maximum temperature of exposure 70 C 158 F a The cab command MUST NOT be located behind the screen T too high and obstruction of windscreen Carrier Transicold Europe 03 09 07 Viento Installation Rev 41 56 Operation amp Service Manual VIENTO Installation Compressor connection MANDATORY BEFORE ANY ELECTRICAL OPERATION DISCONNECT THE VEHICLE BATTERY Remove the battery ground the positive battery and lock out 1 Move along hoses and battery harness to the compressor and vehicle battery 2 Attach regularly the harness with plastic tie wraps and ba
6. Operation amp Service Manual VIENTO INSTALLATION Carrier Transicold Europe 03 09 07 Viento Installation Rev 1 56 Operation amp Service Manual VIENTO INSTALLATION Table of content o RS AA RA 4 Preparation before InstallatiOD ooonoccconccnancnonoconnnnonnnnncnnanncnnannannnnnannannnnna cnn nana nn nono nn rage Ml ceca 5 VENCE DUON et e e it E eee AS lt A 5 Pr 6 BOX o iii SS A A SA 7 BL te PS A Ay A A 7 Roo Op and CUL MOLINO ee aiii aia 8 Sec Lari O aa 11 SC A A MA OA A ii 12 Harness and hoses hole cccssecssscssscsssccsrecssecesscvsssessessserecerecsrecerecersce o O o O coerce coco RBB iii 14 Drain Water MOSS NOS aminorar A a aaa das 15 VUS 6 tt ee ee til R 16 MEIER eT ee ee a E ee A o ere rr er crete 16 OCCUD lira A e A A A A A A A TET 18 Unit insialatio as nm sauteed eawecetncansdecee 19 CE ie ASS O rr AA 19 SMSC tne fe A A A AA tee Teen 21 EvaporalorinstallatioN Minibar 24 AMM ay A GEA A o o 25 Mounting reCOnMiTe nation A _d 0 ii 26 Prepafdio MA TA mi O gna eer er ee err 27 A CG A AA e mm Po A 29 sl Ciel ccc AMM roo A 31 SE PPP A 35 Al VE e ZP PP e A 35 RAT SEensor i 3 Elo AA spac a ates coh adessas apenas tt e E E EE 38 Carrier Transicold Europe 03 09 07 Viento Installation Rev 2 56 Operation amp Service Manual VIENTO INSTALLATION Table of content BIANCA a FECE E 39 Cab comman
7. Refrigeration hoses 3 hoses have to be connected to the evaporator Suction pressure hose from the CRP valve outlet 616 module 12 to the compressor Liquid line hose from the expansion valve through the heat exchanger 8 module 6 to the host unit Hot gas line from the defrost element inlet 8 module 6 to the host unit 1 Run hoses and harness through the hole Suction line Liquid line Hot gas line Fan motor wires RAT cable Injection valve if so equipped 2 Prepare hoses as described in section Unit hoses Preparation p27 Carrier Transicold Europe 03 09 07 Viento Installation Rev 35 56 Operation amp Service Manual VIENTO Installation Evaporator connection Refrigeration hoses 3 Install fitting and connect the SUCTION PRESSURE LINE hose 16 module 12 to outlet of the CPR valve 4 Install fitting and connect the HOT GAS LINE hose with red label 8 module 6 to the drain pan serpentin inlet 5 Install fitting and connect the LIQUID LINE 8 module 6 to the Thermostatic Expansion Valve inlet through the heat exchanger 6 Attach all hoses with plastic tie wraps Carrier Transicold Europe 03 09 07 Viento Installation Rev 36 56 Operation amp Service Manual VIENTO Installation Evaporator connection RAT sensor 7 With the Z6 clamp install the RAT sensor 8 Connect together evaporator fan connectors 9 Put the bottom sk
8. Transicold Europe 03 09 07 Viento Installation Rev 22 56 Operation amp Service Manual VIENTO Installation Unit installation 5 Roof top and roof cut mounting installation m Drill the 4 fixing holes 10 mm in the bottom cover of the unit 6 Nosemount installation m Use the 4 fixing holes at the rear of the frame refer to Box preparation Drilling Nosemount page1 1 7 Using the lifting device P N 07 60110 00 put the unit in place on the 4 silent blocks 8 Roof top and roof cut mounting installation m Fix the unit with the 4 silent blocks and bolts delivered in the packaging 9 Nosemount installation m Fix the unit with the 4 bolts Carrier Transicold Europe 03 09 07 Viento Installation Rev 23 56 Operation amp Service Manual VIENTO Installation Evaporator installation 1 Remove the two side panels 2 Using the adapted tool put the evaporator facing the fixing holes previously drilled 3 Check the minimum distance between the rear of the evaporator and the box is correct refer to the chart p6 4 Tighten the screws Carrier Transicold Europe 03 09 07 Viento Installation Rev 24 56 Operation amp Service Manual VIENTO Installation Hoses Stocking recommendations A RECOMMENDATIONS For a good functioning of refrigeration circuit refrigeration hoses must be clean and dry Hoses must be stocked in a dry area with less variation in temperature a
9. Viento Installation Rev 53 56 Operation amp Service Manual VIENTO Installation Commissioning Settings CPR adjustment 1 Connect manifold to CPR fitting Start the unit in Heating or Defrost mode Check compressor speed 2400 rpm Remove CPR cap on A O N Adjust CPR to get gauge pressure value with hexagonal socket head wrenches n 8 m o raise the suction pressure turn the setting screw clockwise To lower the suction pressure turn the setting screw counterclockwise CPR adjustment R134a R404A Viento 200 2 7 bar jam nut settting screw LA HA Viento 300 1 85 bar 1 25 bar LA HA 6 When the setting has been adjusted tighten the jam nut securely against the setting screw to prevent any movement of the setting screw due to vibrations in the unit 7 Replace the cap Carrier Transicold Europe 03 09 07 Viento Installation Rev 54 56 Operation amp Service Manual Installation Commissioning Settings TXV setting VIENTO ATA th RSCTA ATTY AS Uso Ui A ees ITPRINT ODA dl Carrier Transicold Europe The Thermo Expansion valve is a precision device designed to meter the flow of refrigerant into an evaporator in exact proportion to the rate of evaporation of the refrigerant in the evaporaior The Thermo Expansion valve can control the refrigerant gas leaving the evaporator at a pre determined superheat The superheat is the temperature difference
10. between T1 Temperature measured at remote bulb location and P2 Evaporation temperature of the last liquid drop m 1 Temperature at remote bulb location m P2 Evaporator outlet pressure m S Superheat Viento Installation Rev 55 56 Operation amp Service Manual VIENTO Installation Commissioning Settings TXV setting 1 Connect manifold to evaporator outlet fitting 2 Install a sensor on the expansion valve bulb location 3 Run the unit on COOLING mode 4 Correct superheat Turn anti clockwise to increase flow amp decrease superheat Turn clockwise to decrease flow and increase superheat TXV adjustment Viento 200 8 C at box temperature 0 C 14 4 F at box T 32 F Viento 300 4 C at box temperature 20 C Viento 350 7 2 F at box T 4 F Carrier Transicold Europe 03 09 07 Viento Installation Rev 56 56
11. d harness MINO ee ee 40 El o RR ee 42 Qc Mo Rn ee 44 A O aa iii 49 LEAK AS RR A A A 49 UNEVIGOUR prie EST E e gt ua ja 50 Refrigerant charge iii 51 A A Y A 53 AE A AA A A AA A 53 PAP ee gt n i IT eo 55 Carrier Transicold Europe 03 09 07 Viento Installation Rev 3 56 Operation amp Service Manual VIENTO Installation Introduction This document gives the correct rules to follow in order to correctly install the VIENTO 200 300 350 units SAFETY FIRST MANDATORY BEFORE ANY ELECTRICAL OPERATION DISCONNECT THE VEHICLE BATTERY First remove the battery ground then remove the positive battery PERSONAL PROTECTIVE EQUIPMENT m Always use adequate personal protective equipment before doing anything on this refrigerant unit BODYBUILDER RECOMMENDATIONS m Drain hose from the evaporator to the outside must have an angle to insure water to be drained out A descent of 10 cm minimum must be applied between evaporator drain water hoses and the hoses inside the body picture page 36 Carrier Transicold Europe 03 09 07 Viento Installation Rev 4 56 Operation amp Service Manual VIENTO Installation Preparation before installation 1 Unpack the box contents in your warehouse MN KEEP THE DOCUMENT DELIVERED WITH THE UNIT 2 Unpack the box 3 Check if the box content corresponds to the bill of material on the packaging m Condenser
12. electrical harness and hoses hole 3 Drill the fixing holes drill Y 10mm 4 For roof top mounting drill a hole 80 mm to pass hoses and harnesses Carrier Transicold Europe 03 09 07 Viento Installation Rev 8 56 Operation amp Service Manual VIENTO Installation Box preparation Drilling Roof top and cut mounting 5 Install the 4 silent blocks m put silicone to waterproof on the bottom put silicone to waterproof on the 4 screws before to install the host unit Carrier Transicold Europe 03 09 07 Viento Installation Rev 9 56 Operation amp Service Manual VIENTO Installation Box preparation Drilling Roof top and cut mounting 6 To pass harnesses and hoses between condenser and evaporator drill the electrical harness and hoses hole Roof cut mounting on vertical face of the vehicle Roof top mounting on the roof of the body refer to bodybuilder drawing Carrier Transicold Europe 03 09 07 Viento Installation Rev 10 56 Operation amp Service Manual VIENTO Installation Box preparation Drilling Nosemount 1 Present the drilling template not supplied refer to the bodybuilder drawing 2 Mark out fixing and electrical harness and hoses holes 3 Drill the fixing holes drill 410 mm 4 Drill the electrical harness and hoses hole Carrier Transicold Europe 03 09 07 Viento Installation Rev 11 56 Operation amp Service Manual VIENTO Installation Box p
13. iento Installation Rev 15 56 Operation amp Service Manual VIENTO Installation Box preparation Mushrooms Preparation 1 From box inside drill 4 holes 5 mm in the roof through and through drill of minimum size 140mm 2 Countersink with a drill 12 5 mm the 4 tapping drill holes realized at the previous step RECOMMENDATIONS A Take care not to damage the 5 mm drilling of the box external skin 3 From box outside countersink with a circular slitting saw DZ 22 mm RECOMMENDATIONS A Take care not to damage the 12 5 mm drilling of the box internal skin 03 09 07 Viento Installation Rev 16 56 Carrier Transicold Europe Operation amp Service Manual Installation Box preparation Mushrooms VIENTO Y Preparation DSIRE he Carrier Transicold Europe 4 Measure the roof thickness 5 Adjust the mushroom length L to the roof thickness minus the internal skin thickness E E L mushroom length m roof thickness m internal skin thickness Mushroom in place 1 mushroom silicon gasket skin of external box polyurethane foam skin of internal box evaporator upper side washer 0 N O VI Bb W N screw M12 03 09 07 Viento Installation Rev 1 7 56 Operation amp Service Manual Mushrooms VIENTO Installation Box preparation Carrier Transicold Europe Set up 1 Apply silicon on the internal
14. in in place Carrier Transicold Europe 03 09 07 Viento Installation Rev 37 56 Operation amp Service Manual VIENTO Installation Evaporator connection Drain pan 10 Putthe drain water pipe in place A RECOMMENDATIONS gt A descent of MINIMUM 100 mm must be applied between the drain water hoses pipe and the hoses inside the body to help to drain water out 11 Connect the drain water hoses between drain water pipes and evaporator water tubes 12 Fix tie wrap sockets to maintain drain tubes in the right position 13 Insulate the two holes with silicone 14 Install the two evaporator sides Carrier Transicold Europe 03 09 07 Viento Installation Rev 38 56 Operation amp Service Manual VIENTO Installation Driver cab preparation A RECOMMENDATIONS Before drilling the floor check the location of fuel tank harness and or tubes 1 Drill a hole in the cab floor behind driver or passenger seat depends on battery location A RECOMMENDATIONS Protect the hole ex armoured hose to avoid harness and hoses damage Run water drain hose through the floor Run battery cable through the floor Run the refrigeration hose on fF WB N Run the cab command and ignition cable to the dashboard Install a capping not supplied to cover the hoses and harness Carrier Transicold Europe 03 09 07 Viento Installation Rev 39 56 Operation amp Service Manual VIE
15. linder on scale and connect charging line from cylinder to manifold 3 Purge charging line at inlet manifold 4 Note the weight of refrigerant cylinder Be sure that the unit is stopped during this operation 5 Open liquid valve on refrigerant cylinder and allow the liquid refrigerant to flow into the unit until the correct weight of refrigerant has been added as indicated by weight scale Carrier Transicold Europe 03 09 07 Viento Installation Rev 51 56 Operation amp Service Manual VIENTO Installation Commissioning Refrigerant charge 6 When refrigerant cylinder weight scale indicates that the correct charge has been added close the manifold valves Refrigerant charge Viento 200 0 85 Kg 5 Viento 300 1 Kg 5 Viento 350 1 1 Kg 5 Carrier Transicold Europe 03 09 07 Viento Installation Rev 1152 56 Operation amp Service Manual VIENTO Installation Commissioning Settings CPR adjustment The Compressor Regulation valve is a device designed to regulate the flow of refrigerant returning to the compressor from the evaporator this ensures correct capacity for the unit The Compressor Regulation valve also reduces the load on the compressor during start up amp whilst in operation which is why it is important it is correctly set up on commissioning Adjustment has to be done Road operation Heat or defrost mode Compressor speed at 2400 rpm Carrier Transicold Europe 03 09 07
16. r Transicold Europe 03 09 07 Viento Installation Rev 27 56 Operation amp Service Manual VIENTO Installation Unit hoses Preparation 9 Lubricate the fitting 6 Don t forget to remove the hose cap 7 Insert connector in the hose 8 Crimp the double click clamp with appropriate crimping tool Example of a good preparation The clamp gauge arrow is set between the hose and the fitting stop The clamp bands are perpendicular with the fitting and hose Carrier Transicold Europe 03 09 07 Viento Installation Rev 28 56 Operation amp Service Manual VIENTO Installation Unit connection 1 Run the electrical harnesses and ignition cable inside the vehicle body Carrier Transicold Europe 03 09 07 Viento Installation Rev 29 56 Operation amp Service Manual VIENTO Installation Unit connection 2 Run refrigeration hoses inside the vehicle body 3 Run the drain water hose inside the vehicle body A RECOMMENDATIONS m Always mark off the hot gas line both sides of the hose in order to avoid the confusion with the liquid line hose m Remove caps from the hoses JUST before connecting in order to avoid too much moisture in the circuit Carrier Transicold Europe 03 09 07 Viento Installation Rev 30 56 Operation amp Service Manual VIENTO Installation Unit connection Refrigeration hoses A RECOMMENDATIONS a Always check that O ring is still in place If O
17. reparation Drilling Evaporator A NOTE The drilling depends on the evaporator you have to install Let a minimum space of 150 mm between the box wall and the rear of the evaporator 1 Mark the fixing holes for the evaporator refer to the bodybullder drawing If needed use the fixing material adapted to reinforcement done by the bodybuilder If you don t have reinforcement you will have to use mushrooms refer to section Mushrooms page 16 Carrier Transicold Europe 03 09 07 Viento Installation Rev 12 56 Operation amp Service Manual VIENTO Installation Box preparation Drilling Evaporator a f body reinforced install the insert using the adapted tool manual or pneumatic Carrier Transicold Europe 03 09 07 Viento Installation Rev 13 56 Operation amp Service Manual VIENTO Installation Box preparation Drilling Harness and hoses hole 2 Drill the electrical harness and hoses hole inside the box Carrier Transicold Europe 03 09 07 Viento Installation Rev 14 56 Operation amp Service Manual VIENTO Installation Box preparation Drilling Drain water hose hole 1 If body is not prepared to pass harnesses refrigerant and water drain hoses drill the hose inside body A RECOMMENDATIONS A descent of MINIMUM 100 mm must be applied between the drain water hoses pipe and the hoses inside the body to help to drain water out Carrier Transicold Europe 03 09 07 V
18. s possible and sheltered from moisture The two ends MUST ABSOLUTELY been blocked with tight caps to avoid any internal damages or condensation until their connection into the circuit m lo fit hoses and electrical harnesses use as much as possible RSGU clamps To protect hoses and electrical harnesses use adequate rubber funnels to avoid cutting with metallic corners Carrier Transicold Europe 03 09 07 Viento Installation Rev 25 56 Operation amp Service Manual VIENTO Installation Unit hoses Mounting recommendations ASL oe Do not twist or curve the hose Keep enough length to avoid length variation when the pipes are under pressure m Pipes length can vary between 2 to 4 Using elbows and fittings make easier installations assist accessibility and increase hoses pipes life Wrong installation m Always insure that minimum radius is respected Provide a radius as big as possible to avoid constriction Minimum curve radius Module 6 Module 8 Module 10 Module 12 Carrier Transicold Europe 03 09 07 Viento Installation Rev 26 56 Operation amp Service Manual VIENTO Installation Unithoses Preparation Tools requested 1 Cut the hose at the right length with appropriate tool 2 Put POE oil on the connector on fitting 3 Widen hose clearance with adapted tool before to insert double clic clamp 4 Insert double clic clamp on the hose Carrie
19. se tie wraps onto the chassis 3 Insulate the hole with silicon MN RECOMMENDATIONS Protect or move the harness away from metallic corners of the chassis m Avoid connecting the harness to or in contact with heating source m Avoid connecting the harness to parts that may cause vibrations Do not secure the unit harness to the vehicle harness or piping m Avoid drilling the vehicle frame Carrier Transicold Europe 03 09 07 Viento Installation Rev 42 56 Operation amp Service Manual VIENTO Installation Compressor connection 4 Connect the HIGH PRESSURE HOSE 5 Connect the SUCTION PRESSURE HOSE 6 Connect the OIL RETURN HOSE if available under the compressor Carrier Transicold Europe 03 09 07 Viento Installation Rev 1143 56 Operation amp Service Manual VIENTO Installation Compressor connection Injection thermostat 7 Install injection thermostat on the compressor High pressure line fitting with the clamp A RECOMMENDATIONS Take care to place correctly the thermostat in order to have a good contact with the fitting 8 Fit injection thermostat wires and compressor clutch wires in a retractable sleeve 9 Insert terminals in the injection thermostat Carrier Transicold Europe 03 09 07 Viento Installation Rev 44 56 Operation amp Service Manual VIENTO Installation Compressor connection Injection thermostat 10 Protect the wires with sleeve 11
20. side of the mushroom head 2 Put mushrooms in holes previously realized in box roof 3 With a mallet slightly crush the silicon gasket 4 Follow silent block installation Take care to clean silent block surface for a better sticking water proof ness 03 09 07 Viento Installation Rev 18 56 Operation amp Service Manual VIENTO Installation Unit installation Skin removal 1 Remove the grill Carrier i n m T m remove the 4 fixing nuts m remove the front grill Carrier Transicold Europe 03 09 07 Viento Installation Rev 19 56 Operation amp Service Manual VIENTO Installation Unit installation 2 Remove the top cover m remove the 5 fixing screws m push the cover and remove it Carrier Transicold Europe 03 09 07 Viento Installation Rev 20 56 Operation amp Service Manual VIENTO Installation Unit installation Skin installation 1 Insert the top cover RECOMMENDATIONS Make sure that both sides of the top cover are well engaged as described on the pictures GOOD BAD Carrier Transicold Europe 03 09 07 Viento Installation Rev 21 56 Operation amp Service Manual VIENTO Installation Unit installation Skin installation A RECOMMENDATIONS Make sure that the pins of the front grill are well engaged into the bottom and top covers 2 Put the front grill in place 3 Tie the 4 nuts of the front grill Tie the 5 screws of the top cover Carrier