1414 MS 2HP Delivery System Manual
Contents
1. n a Water Coolant On Off 5 070 0051 CH M u Water Flow 5 070 00 1 Round 3 I ound Gauge 5 070 0107 E i Water Relay ni 5 020 0043 oolids Collector Assembly OO FOOT 5 030 0024 Q Q CONTROL 3 Way Syringe 9 020 0024 DO d 5 070 0159 5 Holder Handpiece 5 020 0280 Auto Hanger Holder 5 020 0280 5 020 0280 4 Orange Constant air in 1 8 Blue Coolant water 1 8 Clear Signal air 1 8 Yellow Constant air in from Master Valve Handpiece 8 Foot Control Tubings Purging Your System Daily Maintenance Purging with air At the end of every day the lines should be purged with air to prevent the growth of biofilm 1 Remove handpieces from tubing Empty the water bottle then reinstall it 1f water bottle is applicable when using city water turn off water from the source 3 Hold the handpiece tubing and syringe over a pail Turn the unit on wait a few moments and then operate the flush toggle if applicable syringe and foot control until water is purged from the system 4 Turn unit off Disinfecting the bottle if applicable Fill the bottle with 100 ml disinfectant solution shake vigorously and let settle for 10 minutes Shake again and then rinse Weekly Maintenance The weekly cleaning procedure should be performed at least once a week preferably at the start of the week before treating patients If the unit is stored
2. D Improper adjustment of water relay If you continue to experience difficulties please call Technical Service Team at 1 800 275 3368 Installation Instructions 4 from Center Back View of Unit 1 Space hanging brackets screws from center on the mounting surface 2 Slide the Control down the hanging brackets screws 3 Install the Control s umbilical to the customer supplied utilities see page 15 Utility Center Plumbing Layout Not to Scale amp Not Included RESERVED FOR 2 OPENING ELECTRICAL IN UTILITY OUTLET CENTER GE AIR IN 7 14 NPT N MALE THREADS VACUUM 2 PVC WATER IN 6 LN 1 14 NPT N MALE THREADS WASTE 2 PVC NOTE pipes must be terminated 1 inch above floor Position box so that 2 opening faces post side Utility Center Tubing Diagram Utility Center not included 1 4 Blue to Cuspidor 1 8 Clear Pilot Air to Unit 1 8 Blue to Unit 1 8 Mellow Master Air to Unite v 8 to Syringe 1 4 1 8 08 619 1 4 Orange Drive Air to Unit Liege EE figure 1 Air Side Air Regulator Part 5 070 0111 1 8 Yellow Master Alr to Unit 2 1 8 Clear Pilot Alr to Unit _ 1 4 Gray to Foot Control 1 4 Orange Drive Air to Unit 1 8 Green to Syringe 1 4 Blue to Cuspidor 1 8 Blue to Unit Jigure 2 Water Side Water Regulator Part 5 070 0103 11 MT Promedt Co
3. us authorized Summit Dental Systems dealer 15 the sole responsibility of said dealer C LISTED e SDS reserves the right to make changes or Improvements on any products without being required to modify existing equipment in a like manner Please complete and retain for your records the following Information In case of warranty part replacement repair or when ordering a part please call your authorized Summit Dental Systems dealer and have the following information available Owners Name Phone Model SDS Serial Dealer Phone 1 U n Purchase Date Important Information Technical Specifications Air Regulator Pressure 80 PSI Water Regulator Pressure 40 PSI Handpiece Pressure 30 35 PSI for most high speed handpieces 40 45 PSI for most low speed handpieces CAUTION When adjusting handpiece pressure do not over tighten screws This may result in unnecessary damage to the handpiece control block e Pay careful attention when unpacking the delivery unit and its accessories Damage caused by mishandling the equipment during unpacking or installation is not covered under warranty e New Owner Please read sign and submit the warranty registration form that is located on page 4 of this manual Failure to return this form may void the warranty e Read this manual carefully If you have any questions please call SDS Technical Service at 1 800 275 3368 SUMMIT DENTAL SYSTEMS Ft La
4. 1414 MINI CONTROL DELIVERY SERVICE MANUAL INCLUDES OPERATION MAINTENANCE TROUBLESHOOTING INSTALLATION VERSION 1 DATED JUNE 1 2003 505 SUMMIT DENTAL SYSTEMS 6277 NW 287 WAY FT LAUDERDALE FL 33309 800 275 3368 954 730 3636 FAx 954 730 3602 WWW SUMMITDENTAL COM Table of Contents WARRANTY S iu E 3 IMPORTANT INFORMATION 1 uuu u Su uu ua u 4 Operator s It e de Scar nx ea xU REED Y ONUS cR REP ES FRE E REF UA RUE EIE MESE 5 FIOW iaa a PURGING YOUR SYSTEM eege 7 TROUBLESHOOTING GUIDE uuu v Pes eo ax E REPE 8 INSTALLATION INSTRUCTIONS 9 Mounting Uhlt to POSE EE Utility Center Plumbing Layout e eee eee ee eee 10 Utility Center Tubing Diagram 11 WARRANTY Summit Dental Systems SDS warrants its products against defects In materials or workmanship from the date of shipment to the Buyer as follows Summit Dental Systems SDS Equipment Warranty Period Chairs Delivery Units Cuspidors Lights 5 Years Control Block Diaphragm part of Delivery Unit Lifetime Upholstery Stools all Plastic Covers and Cabinets Year summit Dental Systems sole obligation under the warranty is to provide parts for repair or at its option to provide a replacement pr
5. e system Disinfectant Solution Use 100 ml 9 parts tap water amp part 5 2596 Sodium hypochiorite household bleach of disinfectant solution for each application per week Always use a fresh mixture every week Troubleshooting Guide SYMPTOM 1 Handpiece Lacks Power 2 Water coolant does not shut off when Foot Control 15 released 3 More than one handpiece is operating 4 Insufficient water coolant 5 Water coolant is running from handpiece while in holder 6 Water coolant is running continuously PROBABLE CAUSE A Check regulator adjustment 80 psi B Check handpiece pressure adjustment on control block C Plugged air filter D Pinched supply tubing Check for kinks E Bad handpiece gasket at connection with tubing F Defective handpiece A Adjust air pressure to 80 psi water pressure to 40 psi B Foot Control is not exhausting C Defective water relay in valve A Handpiece is not completely in the hanger B Improper adjustment of Pilot Valve in the hanger C Kinked or pinched signal line from the Pilot Valve A Adjust coolant flow valve B Water filter may be plugged C Plugged handpiece D Kinked or pinched tubing E Improper adjustment of water relay A Water pressure is too high B Air pressure is too low C Handpiece holder out of adjustment A Purge switch is on on applicable systems B Water pressure is too high C Handpiece holder out of adjustment
6. for any length of time perform the weekly maintenance routine immediately before and after storage Purge the unit with air see Daily Maintenance 2 Hlush the system with disinfectant solution a Turnunit off Empty the water bottle 1f water bottle is applicable replacing the water with cleaning solution see Disinfectant Solution b Remove handpieces from tubing and hold the handpiece tubing and syringe over a pail Turn unit on wait a few moments and then operate the flush toggle if applicable syringe and foot control until a continuous stream of solution is running through the system 3 Allow the disinfectant to remain 1n the unit for at least 10 to 20 minutes and then flush the system again until all the solution 15 used up 4 Purge the unit with air a Hold the handpiece tubing and syringe over a pail Turn the unit on wait a few moments and then operate the flush toggle if applicable syringe and foot control until all solution is purged from the system b Turn unit off If the unit 15 to be stored stop here 5 with clean water a With the unit turned off remove the empty disinfectant bottle 1f applicable Replace with clan bottle and water b Hold Remove handpieces from tubing and hold the handpiece tubing and syringe over a pail Turn unit on wait a few moments and then operate the flush toggle if applicable syringe and foot control until a continuous stream of solution is running through th
7. nsulting GmbH a SDS MMIT DENTAL SYSTEMS REP Altenhofstrasse 80 C Ec D 66386 St Ingbert Germany 6277 NW 28 way Ft Lauderdale FL 33309 Phone 800 275 3368 www summitdental com
8. oduct excluding all labor and shipping fees In any action BUYER S remedies are limited to the warranty described above BUYER shall not be permitted to claim lost profits reliance special incidental or consequential damages in any proceedings The warranty does not cover damage from improper installation or maintenance accident or misuse The warranty does not cover damage resulting from the use of cleaning disinfecting or sterilization chemicals and processes Failure to follow instructions provided in Summit Dental Systems Operation and Installation Manuals Owner s Guides may void the warranty In the event Warranty service must be performed to correct any defect only an authorized Summit Dental System dealer may perform any and all warranty repairs Any repairs by unauthorized dealers technicians or repairmen may void the warranty Inthe case of a defective warranty item a copy of the replacement invoice model and serial number of the product under which it was replaced and a description of symptoms of the defect must be returned with the part within 30 days of the replacement invoice date to Summit Dental Systems 6277 NW Se Way Ft Lauderdale FL 33309 USA in order to receive credit Any and all expenses for freight labor to perform warranty service and purchase of spare parts are the responsibility of the buyer Any fraudulent claims made UL may void the warranty Any additional warranty that may be provided by an
9. uderdale FL USA Product Label Location UR The product label can be publi located on underneath the PRODUCT unit head chassis HERTZ Operator s Instructions Water Coolant Flow Control WATER COOLANT Water On Off Handpiece Toggle Selection SUMMIT DENTAL SYSTEMS Ft Lauderdale FL USA MODEL No S SERIAL No Product Serial Number Label is located PRODUCT underneath Unit Head VOLTS HERTZ AMPS Turn the Handpiece Selection switch to the desired handpiece position 2 The handpieces are automatically activated when removed from their hanger 3 Depress the Foot Control to operate the activated handpiece Pressure is shown on the gauge for the handpiece being used e NOTE Individual handpiece pressure adjustments at the back of the drive air adjustment block located inside the unit To adjust the pressure to each handpiece turn the adjustment screw clockwise to decrease pressure or counter clockwise to increase pressure CAUTION When adjusting the handpiece pressure do not over tighten the screws This may result in unnecessary damage to the handpiece control block 4 To activate water spray turn the Water On Off Toggle to position It is located on the left side edge under the control head Flow adjustment to wet handpieces 1s controlled by the controls labeled Flow Control 1414 Mini Control Flow Diagram Master On Off 5 070 0051