Home
Transfer Motor Likorall ES
Contents
1. Safety INStrUCtIONMS ssoi a E aa a a a a a T EE 2 Maximum Load ssiru a a aA E AN Aa a a a 2 Technical Data saciesas a a aasateseavect 3 DI OTINIVIOMS ienen a E A E EETA 3 Accesso E S na Ea dad a aa A AAEE 3 ASSOMDIY es EN 4 5 Operatiom seruici a a a a aa a EE aaa ENLA NIRE 5 Care and Maintenance siccccicieissssaasicnavedeaseae Hace agetasaeicenads ladauasaedebsaectandaegeaataiede 6 A NOTE This instruction guide contains important information about the use of the product All personnel who use this product must be thoroughly familiar with the contents of this instruction guide Remember to keep the instructions where they are easily accessible for users of the product Safety Instructions Before using for the first time make certain that Before lifting always make certain that e the lift unit and transfer motor have been installed e the lift strap is not twisted or worn and can be run according to the assembly instructions freely in and out of the lift unit e the end stops are securely installed on the rail e lifting devices are properly connected to the lift lifting accessories are not damaged the lifting accessory is correctly and securely you have read and understood the instruction applied to the patient so that there is no risk of guides for the lift unit and lifting accessories personal injury personnel using the lift have been informed of the e the lifting accessory is correctly applied to the correct operation
2. Service agreements Liko invites you to sign a service agreement for regular maintenance and testing of your Likorall system Liko s products undergo continuous development which is why we reserve the right to make product changes with out prior notice Contact your Liko representative for advice and information about product upgrades Recycling For instructions on how the Likorall and transfer motor should be recycled please visit our website www liko com Made in Sweden Liko is quality certified according to ISO 9001 and its equivalence for the medical device industry ISO 13485 Liko is also certified according to environmental standard ISO 14001 1 Liko A CED Company www liko com Manufacturer National Distributor in USA and Canada Liko Distributor in UK Liko AB Liko North America Liko UK Ltd SE 975 92 Lulea 122 Grove Street Brunel Centre Sweden Franklin Ma 02038 USA Stroudwater Business Park info liko se Phone 508 553 3993 1 888 545 6671 Stonehouse Gloucester Fax 508 528 6642 GL10 3RU United Kingdom info liko com Phone 44 0 1453 827272 Fax 44 0 1453 828844 info liko co uk Copyright Liko AB 2009 07
3. L 1 Raise the dampers Loosen the screws 2 pcs 2 Insert the transfer motor on the Likorall s M4x5 on the outside of the transfer motor hous mounting rail The connection cable must be on ing and then remove the housing Loosen the the same side as the end plate with contact on screws 2 pcs M8x25 with lock nuts 2 pcs M8 the lift unit mounted on the profile under the transfer motor 3 Centre the transfer motor on the Likorall and 4 Replace the plastic housing on the transfer motor insert screws 2 pcs M8x25 with M8 lock nuts and affix with screws 2 pcs M4x5 which were which were removed in step 1 in the intended removed in step 1 holes m 3 5 Lower the dampers and connect the cable to the 6 Guide the Likorall with transfer motor onto the contact on the Likorall rail and then mount the end stops on the rail Transfer Motor Likorall ES 7EN120112 01 4 www liko com 7 Apply the intended patient weight load to the Likorall Adjust the tension wheel until the de sired degree of friction between the drive wheel and rail is achieved The tension wheel is ad justed with the aid of a screwdriver To increase friction move the tension wheel to the right to reduce friction move it to the left 8 Connect the handcontrol to the Likorall After assembly check to ensure that e the lift unit a
4. and use of the lift and accessories lifting equipment you have checked to ensure that lifting accessories the sling s strap loops are correctly attached to are not damaged the slingbar before the patient is lifted from the the correct lifting accessory has been chosen with underlying surface but when the sling straps are respect to type size material and version in relation properly extended to the needs of the patient e the patient if using Likorall with a transfer motor alone is provided with a personal alarm the transfer motor can be run in both directions CE Transfer Motor Likorall ES has been tested by an accredited testing institute and complies with the requirements for MDD Class 1 products MDD 93 43 EEC Transfer Motor Likorall ES together with Liko Likorall lift units complies with the requirements of EN ISO 10535 IEC 60601 1 EN 60601 1 2 UL 60601 1 and CAN CSA C22 2 No 601 1 Maximum Load Different maximum loads may apply to different products on the assembled lift system lift unit transfer motor slingbar sling and any other accessories used For the assembled lift system including accessories the maximum load is always the lowest maximum load rating of any of the components For example A Likorall that is approved for 200 kg 440 Ibs can be equipped with a transfer motor that is approved for 250 kg 550 Ibs In this case the max load of 200 kg 440 Ibs applies to the assembled lift system Study the
5. ed each day the Likorall with transfer motor is used Check the lift system for any signs of external damage Check the fixture of the slingbar Check the lift strap for wear and ensure that the strap is not twisted Check the function of the safety latches Check the control function of the lift movement Check to ensure that the lifting height is properly adjusted and that the emergency lowering device functions Charge the batteries each day the lift is used and check to ensure proper charger function Ensure that the transfer motor can be run in both directions Check the friction between the drive wheel and rail When necessary clean the lift with common surface cleaners or disinfectants NOTE Do not use cleaning agents that contain phenol or chlorine since these can damage aluminium and plastic materials Inspection The Likorall and transfer motor should undergo thorough inspection for wear at least once per year Inspection must be performed according to the Liko service manual and by authorized personnel A IMPORTANT Repairs and maintenance may only be carried out by personnel authorized by Liko using original Liko spare parts Transport and storage During transport or when the Likorall and transfer motor are not in use for a long period the emergency stop should be pressed in The Likorall and transfer motor must be stored at a temperature above the freezing point and at nor mal relative humidity not exceeding 60
6. markings on the lift and lifting acces sories and contact your Liko representative if you have any questions Max load 250 kg 550 Ibs Transfer Motor Likorall ES 7EN120112 01 2 www liko com Technical Data Max load 250 kg 550 Ibs Speed of travel 15 cm s 5 9 inch s Electronics Uses Likorall s battery and electronics 24 V 5A Dimensions of WxLxH 148x233x126 mm transfer motor 5 8x9 2x5 0 inch Built in dimension 65 mm 2 6 inch Material Aluminium and plastic Degree of protection IP 43 a The device is intended for indoor use Type B degree of protection against electrical shock Definitions Likorall with transfer motor Transfer motor Transfer motor Lift units Likorall 242 ES 242 ES R2R 243 ES 250 ES Connection cable for transfer motor Handcontrol with 4 buttons Wheel tread Drive wheel Contact plate Plastic housing Tension wheel 0 Damper Transfer Motor Likorall ES 7EN120112 01 Accessories Multistation Prod No 3126110 As an alternative to battery charging via the handcon trol the Likorall with Transfer Motor can be charged via a Multistation The Multistation is installed on the rail system By parking the lift unit at the charging position under the Multistation i e so that the Multistation is aligned with the contact plate on the transfer motor the batteries can be charged www liko com Assembly
7. nd transfer motor functions correspond to the markings on the handcontrol e the transfer motor moves neither too freely nor too heavily adjust the tension wheel see point 7 Operation N e QLiko Liko Operation The Likorall and transfer motor are controlled via light pressure on the buttons on the handcontrol Ar rows mark the direction of travel Travel stops when the button is released Handcontrols for the Likorall with transfer motor have either four or six buttons Travel along the rail is regulated via pressure on the respective button Buttons and are used for control of lifting motion up down Buttons and 2 are used to control switches Transfer Motor Likorall ES 7EN120112 01 Handcontroll Remote IR Prod No 3126060 All models of Likorall ES can be equipped with a wireless handcontrol IR The handcontrol with IR control has six buttons and functions exactly as the cable connected handcontrol see explanation to the left The handcontrol normally functions within a radius of 2 5 metres from the lift unit depending on the angle between the handcontrol and IR receiver on the end plate of the lift unit The Handcontrol Remote IR is equipped with bat teries that should be changed periodically 2 pcs AAA LRO3 www liko com Care and Maintenance To ensure trouble free operation certain components should be check
8. tiko Transfer Motor Likorall ES A CID company Instruction Guide English 7EN120112 01 2009 07 07 Applies to the following models Transfer Motor Likorall ES Prod No 3126044 Product Description Transfer Motor Likorall ES is intended for use with lift independently in the lift system In such cases the units Likorall 242 ES 242 ES R2R 243 ES and 250 ES patient should always be provided with a personal which are equipped with a special outlet for connection alarm to be able to call for assistance if necessary of the transfer motor Other application areas include situations in which the With a transfer motor Likorall is equipped for motorized lift must be operated in areas that afford limited space travel along the rail system and access for the caregiver This is used for example to enable the patient to move In this document the person being transferred is referred to as the patient and the person helping them is referred to as the caregiver A Caution triangles are used to warn of situations that demand extra care and attention C IMPORTANT Read instructions for the lift and accessories carefully before use Lifting and transferring a person always presents a potential risk A thorough understanding of the contents of the instruction guide is essential Only trained personnel should use the equipment If you have questions please contact Liko or your local Liko representative Table of Contents
Download Pdf Manuals
Related Search
Related Contents
HP L1910 19-inch LCD Monitor BEEF IT FltPlan Go iPad Manual Recent Updates バトル1キロ粒剤 ナローギャップセルと後校正機能で ワンランク上の精度をお約束します EVR2310STD version2.1 データシート Rev.C SMARTBATHEX - Essential Supplies Cobra 8500PROHD User Manual Copyright © All rights reserved.
Failed to retrieve file