Home

PORTABLE FIRE PUMPS

image

Contents

1. e E mm U PORTABLE FIRE PUMPS 2011 PRODUCT GUIDE WE MOVE WATER COMPANY PROFILE Wildfire a time honoured company is a world leader in inventing making and delivering premium water handling equipment for firefighters agencies and governments dedicated to wildland fire control Building on Watson Jack amp Co Ltd s entry into the fire control industry in the 1920s when the company initially established itself as a manufacturer of a powerful 200 psi portable fire pump called the WAJAX an acronym of Watson Jack s name our products have evolved throughout the decades thanks to the collaboration of wildland firefighters Best known for the Mark 3 the benchmark in high pressure portable centrifugal pumps Wildfire also manufactures slip ons fireline hardware backpacks forestry tools portable water tanks and other related products We also offer speciality fire hose foam aqueous firefighting gel and much more The upshot of Wildfire s recent management buy out is a return to its roots as a manufacturer driving a renewed emphasis on being the water handling experts With Wildfire s ongoing commitment to the development of innovative products and servicing of its customers we will strive to be recognized as the market leader in wildland and urban interface fire suppression products MISSION STATEMENT Our mission is to Invent Make and Deliver comprehensive water handling solutions Our sen
2. 6 1212A Suction cover with bronze bearing 1 f 1 f 1 7 fra ong tt 8 1243 Gasket 112 8mm Joi Jo 9 1210 Capforprimingpot ot o 10 5538 Retainerforprimingcap ot o 11 A5536_ Protectivecap discharge ot 1 4 12 1273 Paginas Jof oa 13 128 Pumpbody 12 16 st ot 13 188 Pumpbody 18 16 stage tT 13 258 Pumpbody 25 16 stage J pa 14 12 28NS Mechanicalrotaryseal ft a a A 2688 Thread protector 2 NPSH suction Optional incl gasket A 2161 Thread protector 1 1 2 NPSH Optional discharge incl gasket A 7465 Thread protector 1 1 2 NH Optional discharge incl gasket FA 4 1 4 turn quick connect adaptor Optional discharge incl gasket WATERAX psg PU M p N DS www wildfire env com e 1 800 426 5207 B 2 B 2 Pump End The WATERAX B 2 pump end is optimal for moving large volumes of water It can be instantly coupled to the Mark 3 engine or the BB 4 engine with the same coupling system P N 212 170P This practical versatility reduces overall inventory requirements carrying weight capacity and pump downtime in the field It is the ideal pump end for high volume remote watering high volume brush truck and SKIDTANX Slip On units for municipal pumping operations and as for uphill tandem pumping operations Option A 6128 2 1 2 64 mm swivel nut NH B 6076 Ball valve 2 1 2 64 mm less swivel nut Pump Unit
3. A 7493 Cylinder body brass A 6640 8 Spring tension pin 3 16 x 1 1 4 L stainless A 4643 Washer 1 2 ID x 3 4 OD x 0 030 thick nylon y Pin for crank disc Housing for electric priming pump aluminum N o 3 FAST 714 Dowel pin 3 16 X 1 L stainless amp w r 25 WATERAX psg TOOL KITS A 2389 Tool and Accessory Box For carrying pump tools parts and fire line accessories Complete with carrying handle quick action locking latch and continuous hinge Heavy gauge sheet metal painted Weight 5 1 4 Ibs 2 4 kg Measurements 20 x 8 1 2 x 9 1 2 50 x 21 6 x 24 cm A 2388 Pump Testing Kit For testing Wildfire centrifugal high pressure fire pump units models Mark 3 Moskito Mini Striker Striker Il Plus Ultra Striker and BB 4 or other pumps requiring evaluation Can be purchased separately or as a kit consisting of No Item Description 1 A 2392 Pressure gauge liquid filled 0 400 PSI 0 2800 kPa 4 1 2 114 mm dial face 1 4 6 4 mm male NPT 2 F5095 Lined hose coupled 1 1 2 x 10 38 mm x 3 1 m NPSH F5095E00F10RBALFS A 2389 Pump test kit box 4 A 2391 Rubber hose assembly includes a set of 2 adaptors A 2391B 5 A 2391B Adaptor 6 A 2390A_ Shut off valve 7 A 2390 Pressure gauge adaptor 1 1 2 38 mm female to 1 1 2 38 mm male NPSH 8 A 2395 Brass calibrated nozzle set 1 8 1 4 5 16 6 8
4. 7 16 3 mm 6 mm 8 mm 9 5 mm 11 mm 9 C 1933 Calibrated nozzle 1 2 12 7 mm WATERAX pss www wildfire env com e 1 800 426 5207 A 2392 600 Pressure Gauge Pressure gauge used in our A 7198 control panel Liquid filled 0 600 PSI 0 2800 kPa 2 1 2 64 mm dial face 1 4 6 4 mm male NPT low mount front flange Options GAU 213 40 25 0 600 PSI 0 4200 kPa liquid filled 2 1 2 64 mm dial face 1 4 6 4 mm male NPT low mount front A 2392 0 400 PSI dry gauge used in our A 2388 pump test kit GAUGE 1 0 600 PSI for BB 4 and Striker units 180 PART4 0 600 PSI gauge for Deluxe Panel GAU 213 40 25 A 2392 180 PART4 ik 2011 03 2011 03 www wildfire env com e 1 800 426 5207 R 900 Tool Kit for Mark 3 Pump No Item Description 1 PART 117 Grease gun 2 271 923 Wrench adjustable 8 203 mm 3 R 911M Wrench box and open end 13 mm 4 R 906M Wrench box and open end 10 mm 5 R 910 Wrench open end 1 2 x 9 16 6 R 902 Screwdriver 2 51 mm 7 R 904 Wrench spark plug 8 A 3023 Carburetor adjusting tool 9 R 901 Screwdriver 4 102 mm square handle 10 R 903 Feeler gauge spark plug and breaker point 11 R 908 Wrench open end 5 x 8 mm ignition 12 R 905 Handle rod 13 271 928 6mmT handle drain plug wrench 271 488 Bag tool roll Supplied as standard tools with pump unit R 952 Tool Kit for Mark 3 Engine No Item Description 1 R 929 F
5. longer running time 1 5 hours with the integral tank This engine meets the current emissions standards of the US EPA and CARB regulations A Engine Specifications Engine Honda model GX31 4 cycle air cooled Single cylinder overhead valve Maximum power 1 5 HP 1 12 kW Starting system Recoil starter Ignition system Transistorized magneto Carburator Diaphragm type Stroke 1 02 26 mm Bore 1 54 39 mm Displacement 31cc 1 86 cubic inches Lubrication Oil Oil Capacity 0 11 US quart 0 10 L Integrated fuel tank 0 172 US gal 0 65 L Pump Unit Specifications See parts breakdown page 11 13 e Close coupled single stage centrifugal pump e Lightweight aluminum alloy pump parts e Anodized pump parts for corrosion resistance e Mechanical rotary seal e 1 1 2 38 mm NPSH or NH suction threads e 1 1 2 38 mm NPSH or NH discharge threads e Fuel consumption 0 1 US gal hour 0 4 L hour Length 11 28 cm Width 12 5 32 cm Height 12 30 cm Weight 15 Ibs 6 8 kg PORTABLE FIRE PUMPS Features e US Forest Service approved spark arrestor e Inlet and outlet protective caps e Foam solutions pumping capability e Service manual MAN MM3 E e Multi position 4 cycle engine Option e Thread protector 1 1 2 38 mm NPSH NH or 1 4 turn ADP A FM15S ADP L FM15SN or FA 4 75 100 517 50 345 25 PSI kPa 689 172 Maximum Pressure 82 PSI 565 kPa Free fl
6. Specifications e Quick release pump clamp e Lightweight aluminum alloy pump parts e Anodized pump parts for corrosion resistance e Stainless steel shaft e Mechanical rotary seal e 2 1 2 64 mm NH suction and discharge threads e Weight 14 8 Ibs 6 7 kg e Interchangeable on Mark 3 and BB 4 400 2758 BB 4 B2 Maximum Pressure 200 PSI 1379 kPa Free flow 200 US gals min 757 L min MK 3 B2 Maximum Pressure 155 PSI 1068 kPa BB 4 B2 Free flow 180 US gals min 681 L min 300 2068 200 1379 2 MK 3 B2 100 PSI kPa US gals min 50 100 150 L min 189 379 568 Description Qty Kh AA 5 Pump body m SS Grease fitting CS XQ WINS Plug 1 4 NPT brass de Vial Double row ball bearing EAB Rotayseal t WATERAX sq 2011 03 2011 03 www wildfire env com e 1 800 426 5207 D R IVE ASS E M B LY 212 170P Pump Clamp The WATERAX pump clamp is used to couple the B 2 pump end and the 2 stage 3 stage and 4 stage WATERAX pump ends to their respective engines or drive assemblies This easy to use clamp permits the quick exchange of pump ends out in the field for increased versatility and decreased pump downtime Item Part Manual Description Qty A 4460 leversub assemby 1 Ads Sidelinkforlever o C 4462 5 A 4455 B4461 Clamp toph q B 4457 Clamp bottom hat t A 4454 Clevispin eyeboltside f t E A 4456 Knob for tension adjustment 09 A 4453 Eye bolt C 7220 Drive
7. X 32 10 5 x 3 8 x 81 cm Mini Dam shown with Mark 3 fire pump and GSA fuel tank r PORTABLE FIRE PUMPS DIGITAL OVERSPEED SWITCH DOS The new Digital Overspeed Switch DOS continuously monitors the engine s speed through the use of a microcontroller which once overspeed is detected re validates that the condition exists then immediately shuts down the pump Adjustment of a tension spring is no longer required An ON OFF switch is also no longer required This also reduces the amount of wiring and spare parts necessary for each unit Can be installed on any Mark 3 equipped with electronic ignition module CDI Electronic Ignition Module DIC HOURMETER Hour Meter The perfect maintenance solution for monitoring and properly maintaining any gas powered equipment Solid state electronics superb environmental durability and enhanced functionality are the key features of this unit Option MTR 1000 Hour meter With tachometer SenDEC C 7404 Mark 3 Pump Carrying Pack The C 7404 is an economical model carrying pack designed to carry the Mark 3 Fire pump It comes with adjustable nylon straps and also serves as an effective resting surface for Operating the pump on the terrain WATERAX psg PORTABLE FIRE PUMPS BB 4 Portable 4 Stage High Pressure Fire Pump The Wildfire model BB 4 portable fire pump is an ideal unit for high volume remote watering brush truck a
8. brass insert Length 12 1 2 31 7 cm 2 1 2 Ibs 1 1 kg Option B 5980P Hand primer plastic 1 1 2 38 mm female NPSH or NH B 5980P B 5980 WATERAX pq www wildfire env com e 1 800 426 5207 B 5980NH Aluminum Hand Primer Ref Part Description A 5978 3 Tension spring pin Gasket A 5979 B 5980 2 Qty a el a Sis po EG AE Ss a i ai poro pe as i La 08 A3031 Tensionspringpin 1 cme ni as po Saas ay ro ia e E i hs 6 his a 18 1 2011 03 2011 03 www wildfire env com e 1 800 426 5207 B 7498 Electric Priming Pump Piston pump coupled to a short duration rated 12 volt D C motor drawing approximately 105 amperes Made of corrosion resistant materials it measures 9 x 4 1 8 x 7 1 2 229 x 105 x 191 mm and weighs 8 1 Ibs 3 7 kg Priming times 2 x 10 51 mm x 3 1 m hose with 8 2 4 m lift in 4 seconds Maximum vacuum 25 H20 7 6 m H20 22 Hg 560 mm Hg OUT ERA ae rd a OE PRIMERS Part Description A 6147 1 Elbow 1 2 barb to 3 8 male NPT brass 02 B 6601W 27 Adaptor 3 8 male NPT to 3 8 female NPT brass JJ 0 his 4 o A 6617 Diaphragm neoprene coated nylon A 6598 Block check valve plate A 6605 Retaining ring for check valve A 7497 A 7491 N A 7492 Connecting rod aluminum 15 PART 95 Bushing bearing 3 16 ID x 1 4 OD x 3 8 L bronze
9. fuel supply hose with priming bulb FA 131M FA 552 fuel air transport tank only FA 132MIL Funnel R 712 1 4 turn handle R 732 Connector FA 552Q shown with optional A 7487 Fuel dust cap e Es 12 401B NS fuel supply hose 3 with priming bulb and optional R 712 1 4 turn handle FA 352GSA Fuel Carrying Tank US Forest Service approved Heavy duty construction throughout this pick up portable unit has no petcock or other cumbersome protrusions Its self sealing quick coupler enables gasoline line to be changed from one can to another in seconds 5 US gals 18 9 L Option FA 352GSA shown with optional Ra R 1206A fuel line R 1206A 5 1 5 m fuel supply hose with priming bulb and SAE swivel female connectors FA 452 Fuel Carrying Tank The slim design of this marine fuel tank allows storing standing up or lying down Comes with a standard fuel gauge and a 0 9 US gal 3 5 L reserve fuel UL and CSA standards certification for portable marine fuel tanks High density polyethylene permanently red colored Capacity of 6 6 US gals 25 L FA 452 shown with fuel supply hose with priming bulb and handle quick connect 12 401B NS WATERAX psg www wildfire env com e 1 800 426 5207 180 005 01 Wildfire Full Control Panel Yellow faced metal panel with enclosed back includes the following 4 1 2 114 mm liquid filled compound gauge 0 600 PSI 0 4200 kPa and 0 30 0 76 cm vacuum s
10. injury or consequential damage arising out of connected with or resulting from this contract or from the manufacture lease sales delivery resale return repair maintenance handling or use of any product covered by or furnished under this sale shall in no case exceed the purchase price Wildfire shall not be liable for any penalty or for any special indirect or consequential damages including but not limited to any economic loss loss of revenue or loss of opportunity The foregoing warranty is in lieu of all other warranties express or implied including but not limited to any implied warranties of merchantability or fitness for a particular purpose Your exclusive remedy with respect to any and all losses or damages resulting from any cause whatsoever including our negligence shall be repair or replacement as specified above We shall in no event be liable for any consequential or incidental damages of any nature including without limitation damages for personal injury or damages to property and however occasioned whether alleged as resulting from breach of warranty or contract by us or our negligence or otherwise www wildfire env com 1 800 426 5207 WATERAX Tech notes part lists and other documents can be found on our web site at www wildfire env com Wildfire Environmental USA Inc 16311 NE Cameron Blvd 950 Riverside Parkway Suite 50 Portland OR West Sacramento CA USA 97230 USA 95605 Tel 800 426 5207
11. threads e 1 1 2 38 mm NPSH or NH discharge threads e Fuel consumption 0 24 US gal hour 0 9 L hour Length 15 3 4 40 cm Width 10 3 4 27 cm Height 15 3 4 40 cm Weight 19 3 Ibs 8 75 kg WATERAX psg www wildfire env com e 1 800 426 5207 Features e US Forest Service approved spark arrestor e Integrated Low oil shut off e Inlet and outlet protective caps e Foam solutions pumping capability e Service manual MAN MS E Option e Thread protector 1 1 2 38 mm NPSH NH or 1 4 turn ADP A FM15S ADP L FM15SN or FA 4 100 689 Maximum Pressure 85 PSI 586 kPa Free flow 68 US gals min 256 L min 75 517 50 345 25 172 PSI kPa US gals min 25 50 75 L min 95 189 284 2011 03 2011 03 www wildfire env com e 1 800 426 5207 MOSKITO Portable Single Stage Fire Pump This lightweight wildland initial attack pump combines high pressure and flow The position of the 4 stroke pump will not harm the engine due to Honda s unique oil misting system With only 4 bolts the pump end can be easily removed for swapping purposes The Moskito pump can be packed via firefighter or cargo slung via rotary wing aircraft vertically horizontally or upside down into fires The position of the 4 stroke pump will not harm the engine due to this new technology Compared to any two stroke pump in the same class and weight it averages over 40 higher pressure over 50 in noise reduction and 200
12. turn ADP A FM15S ADP L FM15SN or FA 4 e Battery and cable kit A 7612 e Full Control panel 180 005 01 See parts breakdown page 21 e A 2356 Pump end tool kit Maximum Pressure 335 PSI 2310 kPa Free flow 102 US gals min 387 L min PSI 50 100 150 200 250 300 350 kPa 345 689 1034 1379 1724 2068 2413 US gals min 25 50 75 100 125 L min 95 189 284 379 473 2011 03 2011 03 www wildfire env com e 1 800 426 5207 STRIKER II PLUS Portable 2 Stage Fire Pump The Striker Il Plus is capable of providing high pressure nozzle streams for direct attack or volume flow for water delivery at lower pressure Able to work at higher elevations the Striker ll Plus can also be used in tandem or in parallel with other Wildfire pumps This unit provides many interchangeable parts with the MARK 3 BB 4 and other Striker pumps By simply exchanging the pump end the unit can be used as either a high pressure or volume pump This engine meets the current emissions standards of the US EPA and CARB regulations Engine Specifications Engine Honda model GX390 4 cycle air cooled Single cylinder overhead valve 13 HP 10 kW Electric with backup recoil starter Transistorized magneto Maximum power Starting system Ignition system Stroke 2 52 64 mm Bore 3 46 88 mm Displacement 389cc 23 7 cubic inches Lubrication Oil splash Oil capacity 1 16 US quarts 1 1 L Integral fuel tank 1 72 US gals 6 5 L Pump U
13. 100 689 50 345 Maximum Pressure 230 PSI 1586 kPa Free flow 105 US gals min 397 L min PSI kPa US gals min 25 50 75 100 125 L min 95 189 284 379 473 WATERAX psg PORTABLE FIRE PUMPS MINI STRIKER Portable Single Stage Fire Pump This pump unit is designed for use in some of the latest fire control techniques where small lightweight equipment is demanded This pump is powered by a small and lightweight 4 stroke engine that meets the current emissions standards of the US EPA and CARB regulations The Mini Striker unit works well for other applications such as marine services irrigation and the application of foam and other fire chemicals Engine Specifications Engine Honda model GXH50 4 cycle air cooled Single cylinder overhead valve 2 5 HP 1 8 kW Recoil starter Transistorized magneto Maximum power Starting system Ignition system Stroke 1 41 36 mm Bore 1 65 41 8 mm Displacement 49 4 cc 3 cubic inches Lubrication Oil Oil capacity 0 26 US quart 0 25 L Integral fuel tank 0 32 US gal 1 2 L Pump Unit Specifications See parts breakdown page 11 13 e Close coupled single stage centrifugal pump e Lightweight aluminum alloy pump parts e Anodized pump parts for corrosion resistance e Stainless steel shaft e Mechanical rotary seal e Governor system for overspeed protection e Strong polyethylene mounting board with rubber mounts e 1 1 2 38 mm NPSH or NH suction
14. 3 HP 17 2 kW Electric with backup recoil starter Magnetron electronic 16 amp alternator 2 75 70 mm 2 97 75 5 mm 627 cc 38 2 cubic inches Oil full pressure 1 5 US quart 1 42 L replaceable oil filter 1 5 US gals 5 7 L with valve for outside fuel source 3 way valve Pump Unit Specifications See parts breakdown page 11 13 e Quick release pump clamp e Lightweight aluminum alloy pump parts e Anodized pump parts for corrosion resistance e Stainless steel shaft e Mechanical rotary seal e 2 1 2 64 mm NH suction and discharge threads e Weight 14 8 Ibs 6 7 kg e Interchangeable on Mark 3 and BB 4 WATERAX psg PORTABLE FIRE PUMPS ULTRA STRIKER Portable 3 Stage Fire Pump The Ultra Striker is a very versatile and compact unit Capable of providing high pressure nozzle streams for direct attack or volume flow 102 US gals min 387 L min for water delivery at lower pressure The Ultra Striker is a portable unit which can be used on a slip on This unit provides many interchangeable parts with the Mark 3 BB 4 and other Striker pumps It can be used by itself in tandem or in parallel with other Wildfire pumps This engine meets the current emissions standards of the US EPA and CARB regulations Engine Specifications Engine Honda Model GX390 4 cycle air cooled Single cylinder overhead valve 13 HP 10 kW Electric with backup recoil starter Transistorized magneto Maximu
15. Assembly for BB 4 Striker Il Plus and Ultra Striker WATERAX by Wildfire offers an outstanding Drive Assembly that boosts the performance of pump ends The drive assembly increases the speed of pump revolutions resulting in increased pressure and flow The Drive Assembly is used with the WATERAX pump clamp to enable the coupling of the Drive Assembly to the desired pump end Ref Part Description Qty 0 C721 Drive cover assembly Goldasaset 1 02 FASTSO Lock washer steel zincplated 8 03 FAST23 Bolt enginemounting 4 Eren Bushing 1 shaft incl 3 screws 3 lock washers and set screw 5 PARt7 Key 1 4 sq stainlesssteel 1 6 PARE Drvingpuley t O PARA Tmingbet 08 PARE Drivenpey E T Bushing 3 4 shaft incl 3 screws 3 lock washers and set screw 10 FASSO Lockwasher S 6 mo FASA Bolt drive cover assembly 6 12 Fast2 Bolt drive hub assembly 4 13 PART8 Retainingring ext Jo a 14 PART9 Retainingring int fo t 16 A696 Spacerdrvehb 1 17 cos Drivehubboy 18 PARTO Key316 sq stainless steel 1 19 A7239 Shaftassembly drivehub 1 WATERAX psg PRIMERS B 5980 Hand Primer Aluminum A quick and easy way to prime a pump with 2 x 10 51 mm x 3 1 m suction hose and 8 2 4 m lift in less than 20 seconds Particularly useful and effective if pump is used to draw water from well tank etc 1 1 2 38 mm female NPSH or NH
16. RAAXXS 1 1 2 x 8 38 mm x 2 4 m NPSH 3 9 Ibs 1 8 kg 900 PSIG 6300 kPa F3265E25F10RABXXS 1 1 2 x 10 38 mm x 3 1 m NH 4 5 Ibs 2 0 kg 900 PSIG 6300 kPa F3265E25F10RAAXXS 1 1 2 x 10 38 mm x 3 1 m NPSH 4 5 Ibs 2 0 kg 900 PSIG 6300 kPa F3270E25FOSRAAXXS 2 x 5 51 mm x 1 5 m NPSH 3 3 Ibs 1 5 kg 900 PSIG 6300 kPa F3270E25FOSRAAXXS 2 x 8 51 mm x 2 4 m NPSH 4 3 Ibs 2 0 kg 900 PSIG 6300 kPa F3270E25F10RAAXXS 2 x 10 51 mm x 3 1 m NPSH 5 0 Ibs 2 3 kg 900 PSIG 6300 kPa Available on GSA federal supply schedule GS 07F 5128A WIRE REINFORCED SUCTION HOSE Wire reinforced suction hose is designed to give maximum service life under almost any condition Not recommended for tandem operation nor where heavy equipment will pass over the hose Available in 1 to 4 diameter 25 BUC 263 10 to 102 mm in any length up to 50 15 2 m Delivered with male and female rocker lug aluminum couplings Standard Lengths Weight coupled Test Pressure KIT 6 10151N 1 1 2 x 10 38 mm x 3 1 m NH 12 0 Ibs 5 4 kg 230 PSI 1586 kPa KIT 6 10201 2 x8 51 mm x 2 4m NH 12 8 Ibs 5 8 kg 180 PSI 1241 kPa BUC 263 10 2 x 10 51 mm x 3 1 m NPSH 16 0 Ibs 7 3 kg 180 PSI 1241 kPa t Part number subject to change PVC SUCTION HOSE Reinforced lightweight PVC hose specially designed for the Mini Striker to withstand 100 PSI 690 kPa test press
17. RAX psg www wildfire env com e 1 800 426 5207 Performance Standards This standard tests the agent at dilution rates of 0 1 to 1 0 for use on Class A fuels First Class combines excellent wetting characteristics with great foam formation for superior effectiveness on Class A fires Use in ground trucks CAFS Systems helicopter and fixed wing aircraft with buckets scupper and tanks Contains no hazardous material safe for the environment Typical Properties at 77 F 25 C Appearance Pale Amber Liquid Specific Gravity 1 010 pH 7 5 Surface Tension 1 0 Solution 27 00 Dynes cm Viscosity 20 cps Storage If kept in the original unopened and airtight Chemguard supplied container and stored within the temperature range 32 F 120 F 0 C 49 C a shelf life of 20 25 years can be expected When stored in other than the manufacturer s supplied container check with Chemguard for storage guidelines If frozen during storage thawing will render the product completely serviceable Note It is not recommended to premix First Class concentrate with water for long term storage Ordering Information amp Weight Part No Container Weight CGD FC5 5 Gal Pail 19L 45 Ibs 20 3 kg CGD FC55 55 Ga Drum 208 L 495 Ibs 223 kg CGD FC330 330 Gal Tote 1249 L 3000 Ibs 1350 kg Options CGD FCS5 First Class A Foam 5 Gal Pail 19 L CGD FC55 First Class A Foam 55 Gal Drum 208 L CGD FC330 Firs
18. Tel 800 426 5207 503 257 7900 916 372 9004 Fax 503 257 7979 Fax 916 372 9006 Wildfire Environmental Inc 1100 rue Norman street Suite 200 2602 Mount Lehman Road Suite 102 17426 106A Avenue Lachine QC Abbotsford BC Edmonton AB Canada H8S 1A6 Canada V4X 2N3 Canada T5S 1E6 Tel 800 426 5207 Tel 800 426 5207 Tel 800 426 5207 514 637 5572 604 864 4176 780 484 3705 Fax 514 637 3985 Fax 604 864 4186 Fax 780 484 5115 E mail info wildfire env com Distributed by WE MOVE WATER
19. ce e Stainless steel shaft e Mechanical rotary seal with blister resistant carbon seal face and a silicone carbide seat e Governor system for overspeed protection e 2 51 mm NPSH suction threads e 1 1 2 38 mm NPSH discharge threads e Fuel consumption 1 8 US gals hour 6 8 L hour Length 35 89 cm Width 22 1 2 57 cm Height 21 54 cm Weight 171 Ibs 77 kg WATERAX pq 400 500 300 2068 200 1379 100 689 PSI kPa www wildfire env com e 1 800 426 5207 Features e US Forest Service approved spark arrestor e Electric starter low oil protection e Exhaust priming system e Integral fuel tank e Checkvalve NH or NPSH e Powder coated extended steel carry frame e Standard control panel choke throttle on off e Pressure gauge 0 600 PSI 0 4200 kPa GAUGE 1 e Foam solutions pumping capability e Service manual MAN BB4 E Options e B 2 volume 2 stage pump end e Thread protector 2 51 mm NPSH A 2688 e Thread protector 1 1 2 38 mm NPSH NH or 1 4 turn ADP A FM15S ADP L FM15SN or FA 4 e Remote Fuel air transport tank 5 3 US gals 20 L FA 552Q e Steel fuel tank 5 US gals 18 9 L FA 352GSA e Fuel line 12 401B NS or R 1206A e Battery and cable kit A 7612 e Electric priming pump B 7498 e Full control panel 180 005 01 See parts breakdown page 21 e BB 4 Slip On version w Low Tone mufflers less exhaust priming muffler check valve 6 qt fuel tank standard control pan
20. cosity of 10W40 motor oil is 160 centistokes at 77 F 25 C and 800 centistokes at 12 F 11 1 C Surface Tension Water 66 to 76 dynes cm 0 1 SILV EX PLUS solution 27 20 dynes cm 0 6 SILV EX PLUS solution 26 80 dynes cm 1 0 SILV EX PLUS solution 26 60 dynes cm Flash Point gt 200 F 93 3 C Pour Point 22 F 5 5 C FOAM AFFF Aqueous Film Forming Foam ANSULITE 1 concentrate Approvals Listings UL listed freeze protected foam also available ANS 415301 Ansulite AFFF 1 freeze protected 5 US gallons 18 9 L ANS 415303 Ansulite AFFF 1 freeze protected 55 US gallons 208 2 L ANSULITE 3 Concentrate Approvals Listings UL listed FM approved MIL F 24385F on qualified products Freeze protected foam also available ANS 55800 Ansulite AFFF 3 5 US gallons 18 9 L ANS 55809 Ansulite AFFF 3 55 US gallons 208 2 L ANSULITE 6 Concentrate Approvals Listings UL listed FM approved Canadian General Standards Board Canada MIL F 24385F on qualified products ANS 54391 Ansulite 6 5 US gallons 18 9 L ANS 54392 Ansulite 6 55 US gallons 208 2 L ALCOHOL RESISTANT AFFF ANSULITE 3x3 low viscosity concentrate Approvals Listings UL listed USCG approved FM approved ANS 416493 Ansulite 3x3 ARC 5 US gallons 18 9 L ANS 416495 Ansulite 3x3 ARC 55 US gallons 208 2 L ANSULITE ARC 3 and 6 concentrate Approvals Listin
21. e offers an array of 4 Turn also known as quick connect or instantaneous couplings and adaptors The advantage of Y turn is the speed in which hoses and connec tors can be connected and disconnected They also eliminate problems associated with incompatible threads cross thread ing and damage to threads caused from wear in rugged wild land conditions Options FA 7 1 1 2 38 mm 1 4 turn coupling set includes gaskets and expansion rings FA 8 1 25 mm 1 4 turn coupling set includes gaskets and expansion rings FA 12 Gaskets for 1 1 2 38 mm 1 4 turn couplings adaptors and fittings Other sizes and threads also available FA 4 FA 7 FA 8 FIRELINE ACCESSORIES B 5258 Footvalve and Strainer Spring loaded check valve capable of holding a water head equal to 300 PSI Designed with an ear hole for ease of tying to a floatation device in order to prevent suction of debris Specifically made for use on the MARK 3 BB 4 Striker II Plus Ultra Striker and any other pumps using a 2 51 mm NPSH Options KOC BS151 Kocheck 1 1 2 38 mm NH aluminum KOC BS1561 Kocheck 1 1 2 38 mm NPSH aluminum Other threads also available KOC BS151 A 6935 Ball Check Valve Installed on the discharge side of the pump the internal rubber ball instantaneously prevents water return when the pump stops Very useful in uphill pumping to prevent possible damage to the pump from return pressures Thi
22. e with our customers and carries this responsibility with the utmost pride and dedication WARRANTIES A Warranty on Products Distributed by Wildfire Wildfire makes no warranty express or implied with respect to any product distributed by it and manufactured by third party manufacturers You the purchaser can only rely upon such warranties if any that are made by their respective manufacturers and subject the limitations that may be contained in such warranties according to the respective terms thereof Wildfire hereby assigns as applicable any such manufacturer warranty to you as the purchaser if assignable However Wildfire disclaims all other warranties or conditions for items whether express oral implied or otherwise as to any matter whatsoever including but not limited to implied warranties or conditions of merchantable quality or fitness for a particular purpose and those arising by statute or otherwise in law or form a course of dealing usage of trade B Warranty on Products Manufactured by or for Wildfire Wildfire offers a limited warranty as described fully below Among other things it also specifically disclaims liability for e Failure of the product if it is used for other than its intended purpose e Changes or modifications not expressly approved by Wildfire e Unreasonable use supplemental damage or damage to the product not resulting from defects in material or workmanship e Any personal injury damages of any kind
23. el and carry frame e A 2356 Pump end tool kit BB 4 BB 4 Maximum Pressure 425 PSI 2930 kPa Free flow 105 US gals min 397 L min 2758 3447 BB 4 B2 Maximum Pressure 200 PSI 1379 kPa Free flow 200 US gals min 757 L min BB 4 B2 US gals min 50 100 150 200 DDD A 11 L min 189 379 568 758 2011 03 2011 03 www wildfire env com e 1 800 426 5207 BB 4 B2 PORTABLE FIRE PUMPS This BB 4 variation is equipped with a B 2 pump end making it optimal for moving large volumes of water The 2 5 inlet and outlet of the B 2 pump end coupled with the power of the BB 4 unit makes it the ideal pump for high volume remote watering high volume brush truck and Slip On units for municipal pumping operations and as the source pump for uphill tandem operations The B 2 pump end is compatible with and can instantly be coupled to a WATERAX Mark 3 pump using the same coupling system P N 212 170P This practical versatility reduces overall inventory requirements carrying weight capacity and pump downtime in the field This unit s impressive water displacement performance makes it the volume juggernaut of the WATERAX family Engine Specifications Engine Maximum power Starting system Ignition system Charging system Stroke Bore Displacement Lubrication Oil capacity Integral fuel tank Briggs amp Stratton Model Vanguard 4 cycle air cooled Twin cylinder overhead valve 2
24. gs UL listed FM approved ANS 55797 Ansulite 3 and 6 ARC 5 US gallons 18 9 L ANS 55808 Ansulite 3 and 6 ARC 55 US gallons 208 2 L HIGH EXPANSION FOAM JET X concentrate Approvals Listings UL listed FM approved ANS 420008 Ansulite JET X 5 US gallons 18 9 L ANS 420009 Ansulite JET X 55 US gallons 208 2 L PROTEIN FOAM 3 regular protein concentrates Approvals Listings UL listed ANS 73971 Protein foam 3 5 US gallons 18 9 L ANS 73970 Protein foam 3 55 US gallons 208 2 L FLUOROPROTEIN FOAM 3 fluoroprotein concentrates Approvals Listings UL listed ANS 73973 Fluoroprotein foam 3 5 US gallons 18 9 L ANS 73972 Fluoroprotein foam 3 55 US gallons 208 2 L WATERAX psg PO RTAB LE FI RE PU M D CU RVES www wildfire env com e 1 800 426 5207 PORTABLE FIRE PUMP CURVES The WATERAX by Wildfire line offers an array of pumps whose volume and pressure outputs are tailored to the various applications and unique requirements of superior water handling systems 300 400 500 2068 2758 3447 200 1379 NI 100 689 NN WY A US gals min 50 100 150 200 L min 189 379 568 758 BB 4 MARK 3 B2 MOSKITOS BB 49 B2 STRIKER II PLUS MINI STRIKER MARK 3 ULTRA STRIKER WATERAX pes 2011 03 TRAINING AND EMERGENCY SERVICES Wildfire s commitment to customer service and industry knowledge is unparalleled Ever since our entry into the fire control ind
25. it Specifications See parts breakdown page 11 13 e Detachable 4 stage centrifugal pump end Model 12 16 e Quick release pump clamp e Lightweight aluminum alloy pump parts e Anodized pump parts for corrosion resistance e Stainless steel shaft e Mechanical rotary seal with blister resistant carbon seal face and a silicone carbide seat e Digital overspeed cut out switch e 2 51 mm NPSH suction threads e 1 1 2 38 mm NPSH discharge threads e Fuel consumption 1 2 US gals hour 4 5 L hour Length 23 58 cm Width 12 31 cm Height 16 1 4 41 cm Weight 59 8 Ibs 27 1 kg WATERAX voy www wildfire env com e 1 800 426 5207 d at oe i b LL Eo Features e US Forest Service approved spark arrestor e 12 401B NS Fuel line with R 712 1 4 turn handle e Fuel air transport tank 5 3 US gals 20 L FA 552Q or GSA model fuel tank and fuel line e Standard operating tool kit e Powder coated steel frame e Rubber protection caps e Foam solutions pumping capability e Service manual and parts list MANPL MK 3E Options e R 233DS Decompression Switch Assembly except on GSA model e B 2 volume 2 stage pump end e Thread protector 2 51 mm NPSH A 2688 e Thread protector 1 1 2 38 mm NPSH NH or 1 4 turn ADP A FM15S ADP L FM15SN or FA 4 e Fuel line Hansen 1 4 turn e Engine and pump repair tool kits R 900 R 952 A 2356 e C 7404 Backpack carrying frame 400 2758 MK 3 MK 3 Maximum Press
26. lywheel holding tool 2 271 927 Screwdriver Philips No 1 3 271 346 Screwdriver standard 4 R 928 Cap shaft protector 5 R 930 Puller crankshaft bearing 6 R 938 Puller crankshaft bearing 7 R 932 Puller collar coupling 8 R 933 Oil seal pressing tool 9 R 927 Puller magneto 10 R 953 Crankshaft jack 11 R 954 14 Gauge timing 12 R 926 Socket wrench 9 16 13 R 909 Key Allen 3 32 A 2356 Tool Kit for Wildfire pump ends 12 16 25 16 18 16 No Item Description 1 A 1884 Pressing sleeve distributor assembly 2 A 4329 Pressing sleeve rotary seal assembly 3 A 4097 Protector shaft 4 A 1888 Puller suction nozzle 5 A 1890 Pressing pin shaft removal 6 A 1886 Pressing pin distributor removal 7 R 904L Wrench spark plug 8 A 1887 Guide shaft aligning body 9 A 5297 Support tool 10 A 7644 Extraction Tool TOOL KITS R 900 shown rolled up WATERAX psg FIRELINE ACCESSORIES DRAFTEX SUCTION HOSE Lightweight single jacket rigid suction hose all polyester with helical reinforcement Durable flexible and compact This suction hose will with stand 600 PSI 4200 kPa test pressure and is recommended for tandem operation Comes with 2 51 mm male and female NPSH or NH coupling www wildfire env com e 1 800 426 5207 Standard Lengths Weight coupled Burst pressure F3265E25FOSRABXXS 1 1 2 x 8 38 mm x 2 4 m NH 3 9 Ibs 1 8 kg 900 PSIG 6300 kPa F3265E25FOS
27. m power Starting system Ignition system Stroke 2 52 64 mm Bore 3 46 88 mm Displacement 389 cc 23 7 cubic inches Lubrication Oil splash Oil capacity 1 16 US quarts 1 1 L Integral fuel tank 1 72 US gals 6 5 L Pump Unit Specifications See parts breakdown page 11 13 e Detachable 3 stage centrifugal pump end Model 18 16 e Hand primed e Quick release pump clamp e Belt driven speed increaser See parts breakdown page 14 e Lightweight aluminum alloy pump parts e Anodized pump parts for corrosion resistance e Stainless steel shaft e Mechanical rotary seal with blister resistant carbon seal face and a silicone carbide seat e Governor system for overspeed protection e 2 51 mm NPSH suction threads e 1 1 2 38 mm NPSH discharge threads e Fuel consumption 1 14 US gals hour 4 3 L hour Length 33 84 cm Width 21 54 cm Height 21 54 cm Weight 128 Ibs 58 kg WATERAX pss www wildfire env com e 1 800 426 5207 Features e US Forest Service approved spark arrestor e Electric starter e Low oil protection e Hand pump priming system e Powder coated steel carry frame with vinyl grips e Inlet 8 outlet protective caps e Pressure gauge GAUGE 1 e Checkvalve NH or NPSH e Foam solutions pumping capability e Service manual MAN US E Options e ULTRA SLIP version slip on model e Thread protector 2 51 mm NPSH A 2688 e Thread protector 1 1 2 38 mm NPSH NH or quarter
28. mbly this pump end is another popular choice for many SKIDTANX Slip On applications WATERAX pew www wildfire env com e 1 800 426 5207 2011 03 2011 03 www wildfire env com e 1 800 426 5207 CENTRIFUGAL PUMP ENDS Moving Parts Ref Part Description 4 stage 3 stage 2 stage 12 16 18 16 25 16 1 12 50 Locknut stainlesssteel pot poa 2 1249 Lockwasher stainlesssteel Lt tt 3 um a tt 4 us JDsmo po par oo 5 Jum Oring o pa Too KE o a A 7 are Distributor a pa pao O ring o a Oring o 9 12 485 Doublerowballbearing sealed f 1 f 1 f 1 10 1237 Retainingringforbearing J 1 f 1f 1 11 1225 Mach screw stainless steel nyloninsert_ 6 6 6 12 122c Shaftand collar assembly 4stage 1 a 12 1820 Shaftand colar assembly stage 12 2520 Shaftand collar assembly 2stage 13 1247 Couplingbufer Joi par pao 12 2D Shaft sub assembly 4 stage with impellers incl parts with and 7 items 12 2E Shaft sub assembly 4 stage incl parts with 3 items Moving Parts O a N Z AN N NE o S O Ze E r NS PUMP ENDS Fixed Parts Ref Part Description 4 stage 3 stage 2 stage 12 16 18 16 25 16 1 1242 Mach screw stainless steel nyloninsert_ 1 f 1 f 1 2 1238 lokwasherstainlessstel J 9 f 9 9 3 1243 Noseforshat Joa onf or 4 A5537 Protectivecap suction S o 1 a 5 1239 Machscrewstainlessstel f e e 8
29. ment e Foam can be used to protect structures fencing and other resources within the burn e Foam reinforces control lines SCO 4071KIT Foam Inductor Mixer Around the Pump unit for inducting foam concentrate into the hose lines of portable fire pumps such as our Mark 3 used in combating forest and urban wildland fires Calibrated to induct foam concentrate ratios of 0 1 0 5 and 1 into hose lines flowing 8 15 30 50 US gals min 30 57 114 190 L min Kit contains Induction Unit 1 1 2 38mm swivel NPSH tee 2 51 mm swivel NPSH tee pressure connecting hose and foam pickup hose Option KIT SCO 4071W TEES NH version of SCO 4071KIT SC0 4072KIT Mini Around the Pump Foam System Small and economical Mini Around the Pump foam system was specifically designed for our smaller units fire pumps such as our Mini Striker pump The standard unit is calibrated for a 30 US gals min 114 L min nozzle flow rate Giving induction ratios of 0 2 0 5 0 7 and 1 Kit contains induction unit two 1 1 2 38 mm swivel NPSH tees pressure connecting hose and foam pick up hose Optional 50 and 70 GPM Kits Scotty foam inductor mixer shown on a MARK 3 pump Scotty foam inductor mixer shown on a Mini Striker pump WATERAX psg FOAM CHEMGUARD FIRST CLASS A FOAM USFS Approved Chemguard First Class is a biodegradable Class A foam concentrate When mixed with wa
30. nd slip on fire fighting systems in forestry and rural fire environments High pressure up to 425 PSI 2930 kPa is provided to operate very long hose lays and overcome pressure losses due to large elevation changes often encountered in rugged wildland fire operations The higher power makes it ideal for pumping at high altitudes A unique feature of the BB 4 pump is the quick release pump end that is inter changeable with our Mark 3 pump This stan dardization allows for in field pump end exchanges eliminating long equipment down time and greatly reduces the inventory of parts at equipment service shops Engine Specifications Engine Briggs amp Stratton Model Vanguard 4 cycle air cooled Twin cylinder overhead valve 23 HP 17 2 kW Electric with backup recoil starter Magnetron electronic Charging system 16 amp alternator Stroke 2 75 70 mm Bore 2 97 75 5 mm Displacement 627 cc 38 2 cubic inches Lubrication Oil full pressure Oil capacity 1 5 US quart 1 42 L replaceable oil filter 1 5 US gals 5 7 L with valve for outside fuel source 3 way valve Maximum power Starting system Ignition system Integral fuel tank Pump Unit Specifications See parts breakdown page 11 13 e Detachable 4 stage centrifugal pump end Model 12 16 e Quick release pump clamp e Belt driven speed increaser See parts breakdown page 14 e Lightweight aluminum alloy pump parts e Anodized pump parts for corrosion resistan
31. nit Specifications See parts breakdown page 11 13 e Detachable 2 stage centrifugal pump end Model 25 16 e Hand primer e Quick release pump clamp e Belt driven speed increaser See parts breakdown page 11 13 e Lightweight aluminum alloy pump parts e Anodized pump parts for corrosion resistance e Stainless steel shaft e Mechanical rotary seal with blister resistant carbon seal face and a silicone carbide seat e Governor system for overspeed protection e 2 51 mm NPSH suction threads e 1 1 2 38 mm NPSH discharge threads e Fuel consumption 1 14 US gal hour 4 3 L hour Length 33 84 cm Width 21 54 cm Height 21 54 cm Weight 126 Ibs 57 kg PORTABLE FIRE PUMPS wi q BEM a EE Features e US Forest Service approved spark arrestor e Electric starter e Low oil protection e Hand pump priming system e Powder coated steel carry frame with vinyl grips e Inlet 8 outlet protective caps e Pressure gauge GAUGE 1 e Checkvalve NH or NPSH e Foam solutions pumping capability e Service manual MAN S2P E Options e Striker Il Plus slip version pump less gauge primer checkvalve and frame BB 26E PLUS e Thread protector 2 51 mm NPSH A 2688 e Thread protector 1 1 2 38 mm NPSH NH or 1 4 turn ADP A FM15S ADP L FM15SN or FA 4 e Battery and cable kit A 7612 e Full control panel 180 005 01 See page 21 e A 2356 Pump end tool kit 1379 1724 200 250 150 1034
32. ow 48 US gals min 182 L min 50 189 WATERAX psg PUMP ENDS WATERAX PUMP ENDS WATERAX by Wildfire offers a line of premium pump ends The quality reliability and durability of these pump ends are what make them the most trusted in the industry 12 16 4 Stage Pump End This specialized 4 stage pump end typically used on the WATERAX Mark 3 and BB 4 units is essential in water handling operations that require high pressure and involve long hose lays and high elevation This unit moves an impressive volume of water at high pressures notwithstanding the demands resulting from long distances and high elevations It is also the optimal pump end for type 4 and type 6 SKIDTANX Slip On units that demand high pressure The 12 16 s performance and dependability is unmatched 18 16 3 Stage Pump End This high performance 3 stage pump end typically used on the WATERAX ULTRASTRIKER is most effective for water handling operations that require high pressure and involve medium hose lays and moderate elevation Used in conjunction with the WATERAX Drive Assembly this pump end is a popular choice for many SKIDTANX Slip On applications 25 16 2 Stage Pump End This lightweight compact 2 stage pump end typically used on the WATERAX STRIKERII PLUS is most effective for water handling operations that require high pressure and involve shorter hose lays and low to flat elevation condi tions Used in conjunction with the WATERAX Drive Asse
33. r handling systems ae wre N Ah Photo Suzanne Lake fire Sioux Lookout District July 1961 PORTABLE FIRE PUMPS MARK 3 Portable 4 Stage Fire Pump The true benchmark of excellence the WATERAX Mark 3 pump is the most trusted and time tested pump in the industry A truly outstanding and reliable performer it is designed to withstand the rigors and extreme conditions of wildland firefighting Despite its remarkable ability to maintain high pressure over extraordinary distances and elevation it weighs under 60 Ibs and is one person portable a critical attribute out in the field The Mark 3 is the core of superior water handling systems upon which specifications and standards are built around It is no wonder that the Mark 3 has garnered the respect and devotion of forest firefighters everywhere and is the standard Wildland fire pump around the world No matter where forest fires are being fought the familiar buzz of a Mark 3 unit in operation is never far away USDA Forest Service Qualified Specification 5100 274E Engine Specifications Engine Rotax model 185 cc 2 cycle air cooled Single cylinder with replaceable cast iron sleeve Maximum power 10 HP 7 46 kW Starting system Recoil with backup manual rope starter Ignition system Ducati Electronic Ignition Stroke 2 40 61 mm Bore 2 44 62 mm Displacement 185 cc 11 29 cubic inches Lubrication Gas oil mixture ratio 24 1 Pump Un
34. resulting from misuse improper installation negligence repair or alteration of the product No Consequential Damages Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitations may not apply to you This statutory warranty gives you specific legal rights and you may have other rights which vary from state to state or province to province Wildfire offers a limited guarantee of all products manufactured by Wildfire to be free of defects in material and or workmanship for a period of one 1 year from date of invoice subject to use of such products strictly according to instructions Any product manufactured by or for us believed by you to contain a defect must be returned to Wildfire for examination and evaluation You are responsible for payment of transportation charges If after inspection by us or an expert appointed by us the product is in fact found to be defective Wildfire will repair or replace the defective product and reimburse the original buyer for transportation charges to and from our warehouse Limitation of Liability THE WARRANTY SPECIFIED HEREIN IS LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESSED OR IMPLIED Wildfire hereby expressly disclaims any express or implied warranties of merchantability or of fitness for any particular purpose Wildfire s liability on any claim of any kind including negligence for any damage or loss including but not limited to personal
35. s light corrosion resistant alloy valve has a brass pressure relief pin and two 1 1 2 38 mm 1 4 turn connections i B 6397 Automatic Check Valve NH The automatic check valve prevents pressure return 1 1 2 38 mm female NPSH to 1 1 2 38 mm male NH with 1 25 mm female NPT bypass Made with lightweight anodized aluminum material Option NPSH Version available B 6365 SPY 68 15 3 4 700 Pressure Relief Valve Relief valves are used to automatically bypass discharge from pump when nozzle is shut off or pressure becomes excessive The adjustable type is set at 150 PSI 1050 kPa but can be adjusted to any pressure Brass adjustable relief valve 0 700 PSI 0 4900 kPa 3 4 19 mm male NPT to 3 4 19 mm female NPT Also available in 1 2 13 mm WATERAX reg FIRELINE ACCESSORIES FA 5520 Fuel Air Transport Tank Approved for air transport via rotary or fixed wing aircraft Tough lightweight and rust proof with its unique and integrated fuel supply adaptor this container meets the rigid US Military and UN standards certification MIL C 53109 It is the only container to be registered by Transport Canada for UN perform ance packaging certification FUN 3H1 Y1 0 200 yy Can Spr 2 456 2 3mm Seamless all plastic material permanently Olive Drab colored finish 5 3 US gals 20 L Includes inner filter and ball type 1 4 turn fuel supply adaptor B 7462 Options 12 401B NS 51 1 3 m
36. se of urgency when responding to emergency situations is the foundation of our reputation is what makes us the preferred choice in a field where trust matters most TABLE OF CONTENTS Page PORTABLE FIRE PUMPS MARK 3 3 4 BB 4 5 6 ULTRA STRIKER 7 STRIKER II PLUS 8 MINI STRIKER 9 MOSKITO 10 PUMP ENDS 11 13 DRIVE ASSEMBLY 14 PRIMERS 15 16 TOOL KITS 17 18 FIRELINE ACCESSORIES SUCTION HOSES 19 CHECK VALVES 20 FUEL TANKS 21 CONTROL PANELS 21 FOAM 22 24 2011 03 www wildfire env com e 1 800 426 5207 WATERAX WATERAX by Wildfire is a full line of lightweight high pressure portable fire pumps These multistage centrifugal pump systems allow for pumping from natural water sources such as lakes streams and rivers that often contain minor debris A major advantage of high pressure centrifugal systems is that they allow for tandem pumping which enables users to move water over greater distances and elevation WATERAX s origins date back to the 1920s when the Watson Jack amp Co the root company from which Wildfire originated had established itself as a manufacturer of a powerful 200 psi portable fire pump called the WAJAX The first of its kind this pump was the pioneer in the field of portable fire pumps used in forest firefighting The time tested quality reliability and durability of WATERAX pump systems are what have made them the most trusted pumps in the industry today and the benchmark of excellence in forestry wate
37. t Class A Foam 330 Gal Tote 1249 L 2011 03 2011 03 www wildfire env com e 1 800 426 5207 SILV EX CLASS A FOAM SILV EX PLUS is a low medium and high expansion Class A foam concentrate formulated from specialty hydrocarbon surfactants stabilizers corrosion inhibitors and solvents This formulation provides superior cold weather performance The latest development in the original forest fire control concentrate SILV EX PLUS has been proven effective on many deep seated Class A fires such as tire fires paper fires coal fires structure fires and wild fires SILV EX PLUS foam concentrate can be proportioned from 0 1 to 1 0 in fresh brackish or sea water When used as a pre mixed solution only fresh or potable water should be used if the premix is to be stored over long time periods Due to its extremely low proportioning rate SILV EX PLUS foam concentrate offers outstanding economy in concen trate storage space cost compared to conventional 3 and 6 foaming agents and water hauling requirements ANS 434467 Silv Ex Plus 5 US gallons 19 L ANS 434469 Silv Ex Plus 55 US gallons 208 L Meets the requirements of Forest Service Specification 5100 307 Typical Physiochemical Properties at 77 F 25 C Appearance Light Amber Clear Liquid Density 1 010 g ml 0 010 pH 7 0 8 5 Refractive Index 1 3660 0 0035 Viscosity 12 3 centistokes For comparison purposes the vis
38. tarter button start stop switch with LED light night operation light hour meter voltmeter low water pressure safety cut out switch throttle cable a low oil pressure warning light adjustable choke and electric hose reel control with 12 3 6 m remote cable with push button control Available options include a spotlight and a 5 light liquid level monitor Available on GSA federal supply schedule GS 07F 5128A A 7198 Mini Control Panel Black faced metal panel mounted with a 2 1 4 57 mm pressure gauge lock able throttle starter button stop switch and choke Designed to fit our BB4 Ultra Striker Striker II Plus model units A 7612 Battery and Cable Kit Kit designed for centrifugal fire pumps installed with speed increasers belt driven BB4 Ultra Striker Striker II Plus Note Battery provided dry 2011 03 2011 03 www wildfire env com e 1 800 426 5207 WHY USE CLASS A FOAM FOAM e Foam s surfactant improves water penetration of compacted fuels e Foam clings to and blankets the fuel smothering the fire and reducing the air reaching the burning zone e Foam insulates the fuel from radiant heat reducing the formation of combustible gases e Foam sticks to the fuel rather than running off as plain water often does e Foam can be a cost effective tool through slowing or stopping flame spread more rapidly e Foam can be a cost effective tool through reduced resource require
39. ter in the correct proportion it changes the properties of water It reduces the surface tension of the water and produces foam which allows the water to cling to vertical or horizontal surfaces without run off This allows the water to absorb more heat and provides greater penetration into Class A fuels CGD FC5 Features e FULLY QUALIFIED Class A foam concentrate under U S D A Forest Service Specification 5100 307 U L Listed as Wetting Agent NFPA 18 2006 Fully qualified for Fixed Tank Helicopter Reduces water consumption by 3 to 5 times Can be used with either fresh or salt water Suitable with non air aspirating or aspirating handline nozzles e Suitable for use in Helicopter Bambi bucket Compressed Air Foam Systems CAFS Suitable for use on rubber tires coal paper and many other types of Class A fuels Suitable for use through medium expansion nozzles on Class A or contained Class B flammable liquids Suitable for use with high expansion foam generators Does not contain reportable components under SARA Title 111 Section 313 F 40 CFR 372 or CERCLA Recommended Dilution Rates e Helicopter Bambi Bucket 0 5 0 7 e Handline air aspirating nozzle 0 3 0 5 e Handline non air aspirating nozzle 0 3 0 6 e Compressed air foam system 0 1 1 0 Note The above rates vary depending on the type of the foam blanket required Water type quality may also affect foam blanket WATE
40. ure 380 PSI 2620 kPa Free flow 98 US gals min 370 L min 300 2068 MK 3 B2 Maximum Pressure 155 PSI 1068 kPa Free flow 180 US gals min 681 L min 200 1379 O Oo O o nila a x US gals min 50 100 150 200 o o oas oao L min 189 379 568 758 2011 03 2011 03 www wildfire env com e 1 800 426 5207 12 28NS Mechanical Rotary Seal e Rotary seal durability increased at least fivefold e Increases pump reliability by allowing less weeping than the previous seal which also increases longevity of the ball bearing Increased durability under partial dry running conditions Has an integrated drive bushing now made of robust stainless steel Compatible with existing pumps FDT MD 32X32 Mini Dam The Mini Dam is designed for the secondary containment of hazardous materials from fuel and oil spills that occur when operating engine driven gasoline and diesel powered equipment The Mini Dam fits the footprint of most portable pumps and generators It easily collapses for maximum portability and was designed to fit in the Mark 3 kit assembled at numerous fire caches Strengthening rods reinforced corners and grommets are provided to add stability and offer a tie down option The Mini Dam can also be used as a portable sand table for strategic planning Construction 22 oz red heavy duty HPR Dimensions deployed 32 x 32 x 4 81 x 81 x 10 cm collapsed 4 1 2 X 1 1 2
41. ure Available in 1 to 6 25 to 152 mm diameter in any length up to 50 15 2 m Delivered with male and female rocker lug swivel couplings Standard Lengths MK 150 8 Tr ni Side EAYIA A a i CUIT dd tis ic CT natas Weight coupled KIT 6 11152N 1 1 2 x 8 38 mm x 2 4 m NH 3 9 Ibs 1 8 kg MK 150 8t 1 1 2 x 8 38 mm x 2 4 m NPSH 3 9 Ibs 1 8 kg KIT 6 11151N 1 1 2 x 10 38 mm x 3 1 m NH 4 6 Ibs 2 0 kg KIT 6 11202S 2 x 10 51 mm x 3 1 m NPSH 8 0 Ibs 3 6 kg KIT 6 11251N 2 1 2 x 10 64 mm x 3 1 m NH 10 7 Ibs 4 9 kg t Part number subject to change WATERAX psg 2011 03 2011 03 www wildfire env com e 1 800 426 5207 B 5420 V Shaped Hose Strangler Specifically designed for thin walled synthetic hoses it has two positions or settings for different hose wall thickness 1 4 or 1 8 6 or 3 mm Replaceable rubber shoe prevents damage to hose Light corrosion resistant alloy 11 1 2 29 cm long 1 5 Ibs 682 g Can be carried in belt pouch FA 149 The B 5420 models have two settings that are designed to accommodate hose strangling for hoses of different thickness single jacket double jacket etc One setting squeezes tighter than the other Options FA 149 Standard pouch for B 5420 GVP STRANGLER POUCH Red nylon model B 5420P Hose Strangler Painted Red FA 149 FA 3 FA 4 Y Turn Couplings and Adaptors CORDOVA by Wildfir
42. ustry in the 1920s when the company initially established itself as a manufacturer of the powerful 200 psi portable fire pump called the WAJAX we have been involved in manufacturing and distributing a full range of fire fighting equipment Wildfire s expertise in complete systems from the water source to the fire is where our strength lies when serving the wildland and urban interface firefighting community Our distribution network with branches in strategic locations throughout Canada and the United States and export agents in other international markets provide the after sales service which is of utmost importance in the fire service Wildfire has considerable experience in mounting training seminars worldwide for both end users of the equipment and local distributors These seminars include the application of the equipment for fire fighting situations the recovery and maintenance of the equipment as well as workshops on fire control in general Wildfire prides itself on its sense of urgency during emergency situations and its ability to respond quickly when it matters most In fact it is the very foundation upon which Wildfire s reputation is built and is what makes it the preferred choice in a field where trust matters most It is for this reason that Wildfire continues to have a 24 hour emergency line 1 800 426 5207 available year round for sourcing and supplying fire equipment or specific support services Our team loyally works side by sid