1. Product standards e EN 60669 1 1999 A1 2002 A2 2008 e EN 60669 2 2004 A1 2009 e EN 55015 2006 A1 2007 A2 2009 e EN 61000 3 2 2006 e EN 61000 3 3 2008 e EN 61547 1995 A1 2000 Rear view of product 6002 PACK QTY 1 Gang 47mm deep dry lining back box 10 SB632 Tile Thickness 6 35 to 15mm Dimensions 83mm x 83mm x 48mm Cut out dimension 73mm x 73mm A BACK PACK QTY 6003 SB632 1 Gang 39mm deep 1 6003 Dimensions 90mm x 90mm x 39mm DETECTION RANGE ADJUSTMENTS The sensor has an adjustable TIME ON control from 10 seconds minimum to a maximum of 20 minutes approx Light will remain on for the setting time interval after the last movement is 298 detected While there is movement from a heat source in the h detecting area the lighting will remain on and the time will keep resetting 6001 Za HEIGHT RADIUS M TIME TIME High 23 10 2 5 11 2 0 12 Y a E Minimum Maximum 10 seconds 20 minutes 360 The LUX adjustment controls the light level at which the unit will Ser A switch on the light when movement is sensed If set to the maximum position it will switch during daylight If set to the 6002 minimum position it will operate only in total darkness Ideally it 3m HEIGHT RADIUS M should be set at dusk or in the light conditions under which the High x e sensor and lights are expected to operate 3 0 12 LUX LUX ES x x 0 0 NOTE 60
2. e Minder 220 can be swivelled vertically 90 40 e Sensor head can be swivelled horizontally 65 e Can be wall or ceiling mounted e Minder 220 offers rear field anti creep protection e Maximum Switching current 16AX ANCILLIARY ITEMS PACK QTY Corner mounting bracket 1 6887 Manual remote control 1 6841 Service Manual remote control 1 6842 MINDER PASSIVE INFRA RED SENSORS The Minder is a multi adjustable passive infrared movement detector People and animals radiate heat which is invisible to the human eye infrared range Consequently the recorded infrared energy pattern changes when they enter the detection zone DETECTION RANGE DIAGRAMS 220 280 90 Rearfield detection Rearfield detection Rearfield detection Range up to 16m Range up to 16m Range up to 12m Minder 280 Insatallation sites Be aware of trees and bushes Do not install outside lights in detection zone 30 Settings Restrictions of detection i N LED vi 1m 16m 220 amp 280 A pei e is Sd 12m 90 a n 30 The various detection levels To fully cover the surveillance zone the Fresnel lens splits the zone into several overlapping levels Level 1 mS Level 4 x Level 3 Level 3 covers close range detection to prevent undetected entry of the Levels 1 and 2 cover remote surveillance and ensure seamless detection surveillance zone close
3. If set to the maximum position the detection range is about 4m radius If set to the minimum position the detection range is about 0 5m radius a S HEIGHT RADIUS M me BE AEE 4 3 0 SE CE YU NO ION SENSUN PACK QTY Ceiling Motion Sensor 1 6001 e 360 Detection range flush mounting e 24 metre diameter detection zone at 3 metre height e Switching capacity 1000W Incandescent 500VA Fluorescent 500VA Energy Saving Lamp e Photocell Lux adjustment 2 to 1000 LUX e Time adjustment 10 sec to 20 min e Sensor adjustment 4 metre diameter to 24 metre diameter 6001 Product standards e EN 60669 1 1999 A1 2002 A2 2008 e EN 60669 2 2004 A1 2009 e EN 55015 2006 A1 2007 A2 2009 e EN 61000 3 2 2006 e EN 61000 3 3 2008 e EN 61547 1995 A1 2000 Rear view of product 6001 PP FF PD FF Y pm Va E E FP Ah se n TADO YN DO A AA AAN a LIC hr DO J Ba A f p gt L Sy Pe IRRIDOR MOTION SENSOR PACK QTY Corridor Motion Sensor 1 6002 e 360 Detection range flush mounting e 24 metre in length 6 metre width detection range at 3 metre height e Switching capacity 1000W Incandescent 500VA Fluorescent 500VA Energy Saving Lamp e Photocell Lux adjustment 2 to 1000 LUX e Time adjustment 10 sec to 20 min e Sensor adjustment 4 metre diameter to 24 metre diameter e Detection range is achieved by aligning the double arrow lt a along corridor 6002
4. to the wall when the surveillance zone is entered from the outside Level 4 covers the rearfield detection which is activated when the front door is opened from the inside CEILING FLUSH MOUNT MASTER amp SLAVE OCCUPANCY SENSOR 6004 amp 6005 SPECIFICATION 1 POWER 220V to 240V 50Hz 2 Detection range refer to fig 1 3 Time adjustment 30 sec 1min 3min 5min 10min 20min 30min apply to Master sensor only 4 Lux adjustment Light level sensing from 5 to 1000 Lux apply to Master Sensor only 5 Sensitivity adjustment 0 5m to 4m radius Switching capacity 1800W incandescent light 1100VA fluorescent light 1100VA Energy saving lamp 7 Master sensor can be connected to up to 5 slave sensors 8 Warm up 60 sec 9 Test mode Lux adjustment switch to maximum Light turns on for 3 sec in each trigger 10 Short time pulse mode Time adjustment switch to minimum 1 sec ON 9 sec OFF 11 Operating temperature 10 C to 40 C 12 Storage temperature 25 C to 0 C 13 Terminal capacity 2 x 1 5mm WIRING Warning Products should be installed by a qualified electrician Ensure that the sensor is fixed securely to the ceiling without any movement 1 The phase L and neutral N conductors of the supply cable are connected according to terminal assignment 2 The OUTPUT phase L and neutral N conductors are to be connected to the load terminals marked L and N Minimum Maxim
5. 02 detection range is achieved by aligning the double arrow lt gt along corridor MINDER PASSIVE INFRA RED SENSORS The Minder is a multi adjustable passive infrared movement detector People and animals radiate heat which is invisible to the human eye infrared range Consequently the recorded infrared energy pattern changes when they enter the detection zone DETECTION RANGE DIAGRAMS Rearfield detection Additional protection for windows and doors up to the wall of the house even in case of installation directly above doors and windows is provided by the integrated rearfield detection Standard Connection With Break Switch LS 16A LS 16A L L gt N N N Ll He N amp TECHNICAL DATA _ INSTALLATION Horizontal range 90 220 280 The Minder functions optimally when installed lateral to walking direction of detection When selecting the installation site ensure that e The minder is not covered by rigid or moveable objects e g roofing elements Max frontal range 12m 16m 16m branches of tree etc e When unit is installed above or lateral to luminaires a minimum distance is Max bilateral range 6m 16m 10m de always allowed between the unit and the luminaire in order to prevent Water protection IP55 IP55 IP55 maloperation when the unit is installed below luminaires it is not heated up as a result of Switch off delay 1 3 5min 10 sec 30min 10 sec 30min radiant heat from the luminair
6. 02 detection range is achieved by aligning the double Minimum Maximum arrow lt gt along corridor dark operation daylight operation The sensor adjustment controls the detection range If set to the Maximum position detection range is approximately 12m radius if set to the Minimum position detection range is approximately 2m radius SENS SENS aja en dio Minimum Maximum 2m detected range 12m detected range 6841 6842 MINDER 90 220 amp 280 SENSORS IP55 PACK QTY Passive infrared motion detector which switches consumers through a timing element when sources of heat move within its range Minder 90 Deg PIR sensor no remote control 1 6853 surveillance range 12m frontal 6m lateral Minder 220 Deg PIR sensor c w remote control 1 6845 surveillance range 16m frontal amp lateral Minder 280 Deg PIR sensor c w remote control 1 6846 surveillance range 16m frontal amp lateral Dimensions 102mm x 102mm x 182mm e Minder 90 and 220 can be swivelled vertically 90 40 e Sensor head can be swivelled horizontally 65 e Can be wall or ceiling mounted e Minder 90 and 220 offer rear field anti creep protection e Maximum Switching current 16AX MINDER SECURITY 220 SENSOR IP55 PACK QTY Minder Security 220 Deg PIR sensor c w remote 1 6849 control surveillance range 16m frontal amp lateral Dimensions 102mm x 102mm x 182mm
7. Erabtree d pw Occupancy sensors amp PIRs Master amp slave flush ceiling motion sensors Crabtree s range of occupancy sensors are designed to offer a quick and easy plug n play installation whilst offering savings to lighting energy consumption It is estimated that 70 of the UK s lighting consumption is used in commercial applications Studies of several rooms in different commercial environments installed with occupancy sensors show that on average 41 of lighting costs could be saved By using Crabtree s plug n play solution users can achieve these savings with a minimal investment in time and money The versatility of the Crabtree plug n play installation makes the product ideal for coverage in all room shapes as well as a single detection zone having multiple sensor locations The master unit has power connected to a power Supply module Plug n play is then achieved by slave units connecting to each other via a supplied RJ11 cable in a daisy chain arrangement Further to the plug n play Master and Slave system the range is further complimented by a dedicated Ceiling and Corridor Sensor The flush or surface mounted sensors have the largest known detection zone in the market 24 metre diameter when fitted at optimal height The existing Crabtree Minder IP55 PIR range offers solutions for installations in arduous conditions 6004 open showing adjustment dials 6005 open s
8. e k l When mounted at a height of 2 5m the detection range is as above mentioned Dusk sensor in Lux 3 15 Lux 0 5 300 Lux 0 5 300 Lux though deviations in the mounting height cause changes in the detection range Switching Capacity 3680 W VA 3680 W VA 3680 W VA In the case of special conditions at the site e g rows of trees small plot of land proximity to road etc the enclosed masking strip can be used to restrict the Max switching Current 16AX 16AX 16AX detection range by sticking it on the Minder lens Operating Temperature 25 C 55 C 25 C 55 C 25 C 55 C MINDER FAULT FINDING ANALYSIS NATURE OF FAULT REASON FOR FAULT REMEDY Minder does not operate Lens covered or dirty Check power supply uncover and or clean lens Inadvertent operation of Minder Hot air or smoke e g out of kitchens activate Minder Install Minder at a different location Lamp is permanently on Permanent movement in the monitored area Make sure that no heat source is in the detection zone and wait until adjusted time lapse has run down For control purposes please cover the lens completely Minder is bridged to manual operation by Switch to automatic operation additional switch P Electrium i ELECTRIUM SALES LIMITED A SIEMENS COMPANY Commercial Centre Lakeside Plaza Walkmill Lane Bridgtown Cannock WS11 OXE eMail info electrium co uk Web www electrium co uk UK SALES Telephone 01543 455010 Facsimile 01543 455011 eMail crabtree sale
9. howing adjustment dial CEILING MASTER MOTION SENSOR PACK QTY Ceiling Master Motion Sensor 1 6004 e Detection circular 360 e 8 metre diameter detection zone at 2 4 metre height e Switching capacity 1800W Incandescent 1100VA Fluorescent 1100VA Energy Saving Lamp e Time adjustment 30 sec to 30 min e Photocell Lux adjustment 5 to 1000 LUX e Sensor adjustment 1 metre diameter to 8 metre diameter e Power box supplied with master motion sensor e 5 slave motion sensors can be connected in line with 1 master motion sensor e Master motion sensor comes complete with 30cm RJ12 patch cord e Plastic shroud supplied to help mask the lens if there are any undesired areas Product standards e EN 55015 2006 A1 2007 e EN 61547 1995 A1 2000 e EN 61000 3 2 2006 e EN 61000 3 3 1995 A1 2001 A2 2005 e EN 60669 2 1 2004 C1 2007 clause 26 e EN 60669 2 1 2004 C1 2007 e EN 60669 1 1999 A1 2002 A2 2008 exc clause 19 102 101 1 1 2 101 3 CEILING SLAVE MOTION SENSOR PACK QTY Ceiling Slave Motion Sensor 1 6005 e No wiring required e Detection circular 360 e 8 metre diameter detection zone at 2 4 metre height e Switching capacity 1800W Incandescent 1100VA Fluorescent 1100VA Energy Saving Lamp e Sensor adjustment 1 metre diameter to 8 metre diameter e 5 slave motion sensors can be connected in line with 1 master motion sensor e Slave sensor comes complete with 5 metre RJ11 patch cord e Plastic shroud su
10. pplied to help mask the lens if there are any undesired areas Product standards e EN 55015 2006 A1 2007 e EN 61547 1995 A1 2000 e EN 61000 3 2 2006 e EN 61000 3 3 1995 A1 2001 A2 2005 e EN 60669 2 1 2004 C1 2007 clause 26 e EN 60669 2 1 2004 C1 2007 e EN 60669 1 1999 A1 2002 A2 2008 exc clause 19 102 ESA de 101 3 Each power box can have not only one MASTER sensor but also can extend flexibly up to 5 SLAVE sensors 6004 MASTER SLAVE SENSOR SENSOR BG 30cm RJ11 Patch Cord 6005 30cm RJ12 Patch Cord 6004 POWER BOX 0 2m 1x2 RJ12 Patch Cord 5m 1x2 RJ11 Patch Cord NOTE Master x1 Slave x5 Typical maximum layout of master followed by 5 slaves de 18m total E lt 4m Ga AA Master 6004 O i a 2 m E Si YY Ak E Master 6004 LA E Slave 3 5 6005 0 i 9 lt gt LA E yY T 4m 5m 4m ie a a 13m total Determine the best location for the sensor Install the sensor at least 1m away from fluorescent and HVAC ducts and at least 1 3m away from incandescent fixtures and HVAC diffusers 1 Determine the best location for the sensor 2 Drill a 63mm diameter hole in the ceiling The thickness of the ceiling must be between 5mm and 25mm 3 Insert the power module into the ceiling first and then fix the sensor
11. s electrium co uk TECHNICAL Telephone 01543 438310 Facsimile 01543 438311 eMail crabtree technical electrium co uk EXPORT SALES Telephone 44 1543 455049 Facsimile 44 1543 455048 eMail export electrium co uk DUBAI OFFICE Telephone 971 4 3660053 Facsimile 971 4 3660676 Although every effort has been made to ensure accuracy in the compilation of the technical detail within this publication specifications and performance data are constantly changing Latest details can be obtained from Crabtree Publication No A2073 10 12 Printed in England
12. um FIG 1 HEIGHT RADIUS M 24m 2 3 355 AGEE 4 3 0 35 6001 6002 CEILING amp CORRIDOR MOUNT INDOOR MOTION SENSOR SPECIFICATION POWER 220V to 240V 50Hz Fuse T6 3A 250VAC Time adjustment from 10sec to 20min Lux adjustment Light level sensing from 2 Lux to 1000 Lux Range of detection from 2m to 12m radius Detection range can be adjusted using the supplied shroud stickers 6 Switching capacity 1000W incandescent light 500VA fluorescent light 500VA Energy saving lamp 7 6001 6002 detection range please refer to the fig 2 8 Auto mode Test mode Timer mode 9 Operating temperature 10 C to 40 C 10 Storage temperature 25 C to 70 C 11 Terminal capacity 2 x 1 5mm Li aa WIRING Warning Products should be installed by a qualified electrician Ensure that the sensor is screwed securely to the ceiling without any movement 1 The phase L and neutral N conductors of the supply cable are connected according to terminal assignment 2 The output or load phase L and neutral N connectors are to be connected to the load terminals marked L and N 6001 6002 INSTALLATION 1 Fuse can be replaced by using a screwdriver to pull up the fuse FIG 2 360 be edi A 6001 E HEIGHT RADIUS M High 23 10 255 11 3 0 d gt 360 n A 6002 3m HEIGHT RADIUS M High E HA 30 12 ay NOTE 60
13. with metal spring as shown Power Module ADJUSTMENTS The sensor has an adjustable TIME ON control from 30 seconds minimum to a maximum of 30 minutes Light will remain on for the setting time interval after the last Movement is detected While there is movement from a heat source in the detecting area the lighting will remain on and the time will keep resetting aa Jo ea I 30S SS 20 30S e Sy 20 PULSE Ox PULSE 30 Master only If time adjustment is set to PULSE the sensor will enter short pulse mode In short pulse mode the sensor will send a signal to the device The signal will be 1 sec ON and 9 sec OFF Y 3 5 1 10 tly 30S ii 20 o O PULSE SA Master only The LUX adjustment controls the light level at which the unit will switch on the light when movement is sensed If set to the maximum position it will switch during daylight If set to the minimum position it will operate only in total darkness Ideally it should be set at dusk or in the light conditions under which the sensor and lights are expected to operate 34 eda SE a TEST TEST Master only If LUX adjustment is set to maximum the sensor will enter TEST mode In TEST mode the light will turn on for 3 sec when PIR is triggered Check the detection area and adjust sensor to the desired angle Afterwards it can be switched back to desired time setting E SS TEST Master only The sensor adjustment controls the detection range