840 Ventilator System

image

Contents

1. CE 0123 tyco Healthcare Puritan Bennett Selection Required REF Description Oxygen hose assembly 4 001474 00 DISS United States 4 074697 00 Air Liquide France 4 074698 00 NIST BOC United Kingdom Ireland 4 074700 00 NIST Netherlands 4 074702 00 DISS Israel Japan Saudi Arabia 4 074705 00 DISS Egypt India Italy Kuwait Poland Portugal South Africa 4 074708 00 DISS Switzerland 4 074710 00 DISS Canada 4 074711 00 SIS Australia New Zealand 4 074715 00 DISS Drager Germany Air hose assembly 4 006541 00 DISS United States 4 074696 00 Air Liquide France 4 074713 00 NIST BOC United Kingdom Ireland 4 074701 00 NIST Netherlands 4 074703 00 DISS Israel Japan Kuwait Poland Portugal South Africa 4 074704 00 DISS Saudi Arabia 4 074706 00 DISS Egypt India Italy 4 074707 00 DISS Switzerland 4 074709 00 DISS Canada 4 074712 00 SIS Australia New Zealand 4 074714 00 DISS Drager Germany Power cord 4 071420 00 North America 4 031322 00 United Kingdom 4 071424 00 Japan 4 031320 00 Australia 4 031321 00 Europe 4 071421 00 Denmark 4 031323 00 Italy 4 031325 00 Switzerland 4 071422 00 India South Africa 4 071423 00 Israel 4 031321 00 Russia Operator s and technical reference manual 4 070088 00 English U K 4 075609 00 English U S 4 070145 00 French 4 070144 00 German 4 070146 00 Italian 4 070151 00 Japanese 4 070148 00 Portuguese 4 070147 00 Spanish Software options
2. 840 Ventilatc iy r System Innovertiye toe ae ILALA NG Bei Orne nes li if Da TS cl en tyco Healthcare Puritan Bennett ee S i PP at zi TEE aiii ya 2 LATTER LEC i p E ns JE tyco Healthcare Puritan Bennett 840 Ventilator System The 840 Ventilator is an evolution in critical care ventilators Compact and lightweight it delivers sensitive precise breaths to critically ill infant Paediatric and adult patients With its high performance pneumatics and dual microprocessor electronics the 840 platform will accommodate technology updates well into the 21st century Features amp Specifications Intelligent User Interface e DualView liquid crystal display LCD Touch Screens display monitored data separately from ventilator settings for easy assessment of your patient s condition e The SandBox screen area lets you set up and review all proposed ventilator and alarm limit settings before you apply them to your patient You can change any proposed setting or press the CLEAR key to cancel No settings are applied to the patient until you press the ACCEPT key e The SmartAlert Alarm System prioritizes alarm annunciation Primary alarms are distinguished from secondary dependent alarms which helps you to efficiently resolve root causes of alarms e The setting for ideal body weight IBW establishes boundaries that help prevent application of inappropriate ventila
3. Apnea ventilation Apnea mandatory type volume Flow by flow triggering control VC or pressure control PC Apnea flow pattern Square or descending ramp Apnea peak flow Vaod 3 to 150 L min for IBW gt 24 kg 3 to 60 L min for IBW lt 24 kg Apnea inspiratory pressure P 5 to 90 cmH O Apnea inspiratory time T 0 2 to 8 0 seconds Apnea interval T 10 to 60 seconds Apnea respiratory rate f 2 0 to 40 min Apnea 0 21 to 100 Apnea I E ratio lt 1 00 1 Apnea expiratory time T Te gt 0 2 second Disconnect sensitivity Dgeng 20 to 95 Humidification type Heat moisture exchanger HME non heated expiratory tube or heated expiratory tube Patient circuit type Pediatric or adult Alarm Limits High circuit pressure Pene 7to 100 cmH O High exhaled minute volume TVE tor 0 1 to 99 9 L or OFF High exhaled tidal volume TV _ 50 to 3 000 mL or OFF High respiratory rate Mor 10 to 110 min or OFF Low exhaled mandatory tidal volume Vi MAND 5 to 2 500 mL or OFF Low exhaled minute volume LV tor 0 01 to 60 0 L Low exhaled spontaneous tidal volume We spont 5 to 2 500 mL or OFF Monitored Data Breath type Indicates the type control assist or spontaneous and phase inspiration or exhalation of the breath being delivered Delivered 0 End expiratory pressure P gnp End inspiratory pressure P gnp Exhaled minute volume Ve Tor Exhaled tidal volume V LE ratio Maximum circuit pre
4. BiLevel For specific part numbers call your local Mallinckrodt sales representative Optional Accessories REF Description 4 070089 00 Service manual English 4 075315 00 Wall air water trap kit Patient breathing circuit G 061235 00 Reusable adult with heated wire for Fisher amp Paykel G 061208 00 Reusable adult without heated wire G 061237 00 Reusable pediatric with heated wire for Fisher amp Paykel G 061223 00 Reusable pediatric without heated wire Inspiratory bacteria filter 4 074601 00 Disposable D Flex carton of 12 Expiratory bacteria filter and collector vial 4 070315 00 Disposable filter D X800 carton of 12 4 048491 00 Drain bag disposable package of 25 4 048493 00 Drain bag tubing disposable package of 10 4 048492 00 Clamp reusable package of 5 4 074613 00 Drain cap 4 070311 00 Seal expiratory filter Mounting kit humidifier 4 075313 00 Fisher amp Paykel 480 730 4 076102 00 Cart ventilator 4 072214 00 Oxygen sensor 4 070523 SP Battery replacement kit 4 079046 00 10 000 hour preventive maintenance kit BDU GUI 10 000 hour preventive maintenance kit compressor For specific part numbers call your local Mallinckrodt sales representative 4 074374 00 Filter compressor inlet Oxygen sensor to be replaced every 2 years or as necessary by a qualified service technician Preventive maintenance kits must be installed by a qualified service technician CE m
5. environment operation at higher temperature or FIO levels will result in shorter sensor life Gas mixing system Range of flow from the mixing system Can be set to 150 L min standard temperature and pressure dry STPD for patients gt 24 kg and up to 60 L min for patients lt 24 kg Additional flow is available up to 200 L min for compliance compensation Leakage from one gas system to another Meets standard EN 794 1 Operating pressure range 35 to 100 psi 241 to 690 kPa Alarm volume Approximately 45 db A to 85 db A Due to excessive restriction of Drager Air Liquide and SIS hose assemblies reduced ventilator performance may result when air or oxygen supply pressures lt 50 psi 345 kPa are employed Specifications subject to change without notice Power Input power Ventilator operation without compressor and with Fisher amp Paykel MR730 Humidifier 100 V ac 50 Hz 5 1 A 220 240 V ac 50 Hz 1 5 A 100 V ac 60 Hz 5 1 A 220 240 V ac 60 Hz 1 5A 120 V ac 60 Hz 4 5 A Ventilator operation with compressor and with Fisher amp Paykel MR730 Humidifier 100 V ac 50 Hz 10 7 A 220 240 V ac 50 Hz 4 1 A 100 V ac 60 Hz 10 7 A 220 240 V ac 60 Hz 4 1 A 120 V ac 60 Hz 10 1 A Mains overcurrent release Ventilator 5 A 100 and 120 V ac 5 A 220 240 V ac Auxiliary mains 10 A 100 and 120 V ac 5 A 220 240 V ac NOTE Above values obtained using the following ventilator settings at 72 F 22 C ambient tem
6. arked indicating compliance to the European Medical Device Directive 93 42 EEC 800 Series Puritan Bennett 840 DualView SandBox SmartAlert BiLevel Flow by Re Flex Re X800 D Flex and D X800 are trademarks of Mallinckrodt Inc 2002 Tyco Healthcare All rights reserved Tyco Healthcare UK Limited 154 Fareham Road Tyco Healthcare Regional 154 Fareham Road GOSPORT GOSPORT Hampshire Hampshire PO13 0AS PO13 0AS UK UK Tel 44 0 1329 224226 Fax 44 0 1329 224334 Tel 44 0 1329 224258 Fax 44 0 1329 224086 Tyco Healthcare Birchwood Court Montrose Road PO Box 8108 Halfway House 1685 MIDRAND SOUTH AFRICA Tel 27 0 11 265 2000 Fax 27 0 11 265 2050 Gardsvagen 18 SE 169 67 SOLNA SWEDEN Tel 46 0 8 585 605 05 Fax 46 0 8 585 605 06 www tycohealthcare com Tyco Healthcare Norden AB M 840TECH GB Export Tyco Healthcare Nederland BV Hogeweg 105 5301 LL ZALTBOMMEL The NETHERLANDS Tel 31 418 57 66 00 Fax 31 418 57 67 93 TycoHealthNed TycoHealth com www tycohealthcare nl Tyco Healthcare Belgium N V S A Generaal de Wittelaan 9 5 B 2800 MECHELEN BELGIUM Tel 32 0 15 29 44 50 Fax 32 0 15 29 44 55 tycohealthcare belgium tycohealth com 08 2002
7. arts and labor Environmental Specifications Pneumatic Gas Sources Air and oxygen Must be supplied at 35 100 psi 241 690 kPa Temperature Operating 50 to 104 F 10 to 40 C at 10 to 95 relative humidity noncondensing Storage 4 to 122 F 20 to 50 C at 10 to 95 relative humidity noncondensing Atmospheric pressure Operating 10 2 to 15 4 psi 700 to 1 060 hPa Storage 7 3 to 15 4 psi 500 to 1 060 hPa Altitude Operating 1 350 to 10 000 ft 443 to 3 280 m Storage up to 20 000 ft up to 6 560 m Physical Characteristics Weight Breath delivery unit BDU 40 1 Ib 18 2 kg Graphic user interface GUI 12 6 Ib 5 7 kg Backup power source BPS 14 6 Ib 6 6 kg Cart 34 2 Ib 15 5 kg Compressor 69 7 Ib 31 6 kg Dimensions BDU 13 H x 18 W x 10 D 330 mm H x 457 mm W x 254 mm D GUI 18 1 H x 15 5 W x 6 7 D 460 mm H x 394 mm W x 170 mm D BPS 3 25 H x 9 6 W x 10 D 83 mm H x 244 mm W x 254 mm D Cart 39 3 H x 22 9 W x 23 7 D 998 mm H x 582 mm W x 602 mm D Compressor 16 4 H x 18 W x 14 25 D 417 mm H x 458 mm W x 362 mm D Connectors Inspiratory limb connector ISO 22 mm conical male Expiratory limb connector on expiratory filter ISO 22 mm conical male Air and oxygen inlets DISS DISS female NIST BOC Air Liquide or SIS fitting depending on country and configuration Oxygen sensor life Two years or 10 000 hours of use nominal actual life depends on operating
8. eveloped in accordance with pertinent FDA guidances and North American and international standards The ventilator s IEC 601 1 EN 60601 1 classification is Protection Class I Type B internally powered drip proof equipment continuous operation The ventilator meets all requirements for Electromagnetic Compatibility EMC under the standard IEC 601 1 2 including CISPR II Group I Class B Certified by Canadian Standards Association CSA to the following international standards and requirements under the CB Scheme IEC 601 1 Amendments 1 and 2 IEC 601 2 12 Approved to the type test requirements of Annex III of the Medical Device Directive 93 42 EEC and bears the CE marking Certified by TU V Rheinland to the following standards and requirements 220 240 V units EN 60601 1 Amendments A1 and A2 EN 60601 1 1 EN 60601 1 2 EN 794 1 Also complies with the following standards EN 60601 1 4 IEC 601 1 IEC 601 1 1 IEC 601 1 2 IEC 601 1 4 ISO 10651 1 Ordering Information 840Ventilator To order call your local Mallinckrodt sales representative Standard Accessories REF Description 4 032006 00 Flex arm 4 074600 00 Inspiratory bacteria filter Reusable Re Flex each 4 070305 00 Expiratory bacteria filter and collector vial Reusable filter Re X800 each 4 074647 00 Reusable collector vial Re X800 each 4 018506 00 Test hose 4 000612 00 Test lung 4 070520 00 802 Backup power source BPS
9. perature mode A C mandatory type PC IBW 85 kg f 20 min Pgypp 30 cmH O T 1 second flow acceleration 50 0 50 Porc mayo 50 cmH 0 Psens 3 cmH 0 Humidifier connection only available on 100 and 120 V ventilators Leakage current Earth leakage current 120 V ac operation 300 yA max Enclosure patient leakage current 120 V ac operation 100 JA max Patient auxiliary leakage current Not applicable no applied parts Humidifier leakage current 220 to 240 V ac operation 100 pA max 802 Backup Power Source BPS 24 V dc 6 5 Ah Operating time for a new fully charged battery At least 30 minutes actual duration depends on ventilator settings battery age and level of battery charge Recharge time Automatically recharges within 8 hours maximum while ventilator is connected to ac power Shelf life 24 months from date of manufacture Storage conditions Store at 4 to 122 F 20 to 50 C 25 to 85 humidity avoid direct sunlight Recharge requirements Recharge every 6 months when storage temperature is 5 to 84 F 15 to 29 C every 3 months when storage temperature is 86 to 104 F 30 to 40 C every 2 months when storage temperature is 105 to 122 F 41 to 50 C NOTE BPS battery life specifications are approximate To ensure maximum battery life maintain full charge and minimize the number of complete discharges tyco Healthcare Puritan Bennett Compliance and Approvals The 840Ventilator System was d
10. ssure Poire max Mean circuit pressure Poire Spontaneous minute volume Ve SPONT Total respiratory rate ftor Integral waveforms function includes choice of e Pressure time curve flow time curve volume time curve or pressure volume loop one or two waveform curves or one pressure volume loop can be displayed at the same time Pressure volume loop automatically calculates inspiratory area All waveforms can be frozen e Adjustable baseline and vertical horizontal axis scales e Waveforms are automatically displayed and frozen when you press INSP PAUSE or EXP PAUSE In INSP PAUSE the calculated values for compliance and when possible resistance are displayed after the inspiratory pause In EXP PAUSE the measured values for intrinsic and total PEEP are displayed during and after the expiratory pause Ventilator Status Indicators High urgency alarm blinking if active steadily lit if autoreset Medium urgency alarm blinking if active turns off if autoreset Low urgency alarm steadily lit if active turns off if autoreset Normal operation Normal BDU operation Ventilator inoperative Normal GUI operation Loss of GUI Safety valve open Backup Power Source BPS ready Ventilator operating on BPS BPS charged BPS charging Compressor ready Compressor supplying air to the ventilator Other Keys and Indicators Screen lock key When lit touching the screen or offscreen controls has no effect until yo
11. tor settings e Entering Ideal Body Weight IBW automatically creates default settings and alarm limits which may either be quickly accepted for rapid setup or adjusted as needed e Once settings are applied the ventilator offers an undo function that allows you to return to previous settings quickly and easily Ventilator Settings Ideal body weight IBW 7 7 to 330 7 Ib 3 5 to 149 kg Modes Assist Control A C synchronous intermittent mandatory ventilation SIMV or spontaneous SPONT Optional BiLevel Spontaneous breath types Pressure supported PS or none Pressure support P ypp O to 70 cmH O Flow acceleration 1 to 100 Expiratory sensitivity Esens 1 to 45 Mandatory breath types Volume control VC or pressure control PC Tidal volume V 25 to 2 500 mL Respiratory rate f 1 0 to 100 min Peak inspiratory flow Wixi 3 to 150 L min for IBW gt 24 kg 3 to 60 L min for IBW lt 24 kg Flow pattern Square or descending ramp Plateau time Tp 0 0 to 2 0 seconds Inspiratory pressure P 5 to 90 cmH O Constant during rate change Inspiratory time T LE ratio or expiratory time T Inspiratory time T 0 2 to 8 0 seconds I E ratio lt 1 299 4 00 1 Expiratory time T T gt 0 2 second Trigger type Pressure Pp g or flow Virc Pressure sensitivity Pgeng 0 1 to 20 cmH O below PEEP Flow sensitivity V gens 0 5 to 20 L min 0 21 to 100 PEEP 0 to 45 cmH O
12. u press screen lock again New alarms automatically unlock the screen and controls Display contrast key Adjusts screen contrast monochrome only Display brightness key Adjusts screen brightness monochrome only Alarm volume key Adjusts alarm volume alarm volume cannot be turned off Alarm silence key Turns off alarm sound for 2 minutes Alarm reset key Clears active alarms or autoresets high urgency alarms cancels an active alarm silence and is recorded in the alarm log key Displays basic operating information about the ventilator 100 O CAL 2 min key Delivers 100 oxygen if available for 2 minutes and calibrates the oxygen sensor MANUAL INSP key Delivers one manual breath to the patient according to the current mandatory settings EXP PAUSE key Allows you to measure auto PEEP not functional in SPONT and has no effect during the inspiratory phase of a breath INSP PAUSE key Allows you to perform static mechanics maneuvers Knob Adjusts the value of a setting A button that is highlighted means that the knob is linked to that setting CLEAR key Cancels a proposed setting ACCEPT key Applies proposed settings Software Options BiLevel Low PEEP PEEP Range 0 to 45 cmH O High PEEP PEEP Range 5 to 90 cmH O Low PEEP time T Range 0 2 second High PEEP time T Range gt 0 2 to 30 seconds Ratio of PEEP time to PEEP time T T Range 1 299 149 1 Warranty One year p

Download Pdf Manuals

image

Related Search

Related Contents

SAFEX Nutron Front End User Manual  Trim Only for Volume Control Valve Grifería de la Válvula  S-A1 - Steyr Mannlicher  Avteq LED-1 flat panel wall mount  Emtec ECMMD8GF102 USB flash drive  UM SAD-18-I (W2-303-186-CTP  Etude du ruissellement et de l`infiltration : la technique des  Electric Power Assisted Cycles  Imp X7-S_sp:1_Impressa X7-S_D  Lenovo E10-30  