Home

Industrial Indicators Terminal Mode Serial Communications

image

Contents

1. Avery Weigh Tronix Industrial Indicators Terminal Mode Serial Communications 3 1 3 Enquire Terminal Mode Purpose Allows the PC to determine the indicator s mode of operation Command lt STX gt AT lt ETX gt Response Terminal indicator is in dumb terminal mode Normal indicator is normal weighing mode Mode Anytime Indicators All 3 1 4 Clear Display Purpose Clears the text and the graphics from the display Also clears any dummy soft keys that have been created by a remote application Command lt STX gt CS lt ETX gt Response ACK display cleared NAK indicator in normal weighing mode Mode Terminal mode Indicators All 3 1 5 Display Text Message Purpose Displays a text message on screen Command lt STX gt DT data lt ETX gt 2 char x co ord 1 to 40 2 char y co ord 1 to 64 message Response ACK NAK Mode Any mode L NOTE If the comms channel is configured for use with the PAK KING application then in normal weighing mode all text messages will be forced to the data entry line of the display Indicators All except E1105 Avery Weigh Tronix 2007 Version 3 0 Issued October 2007 Page 9 of 32 Industrial Indicators Terminal Mode Serial Communications 3 1 6 3 1 7 Avery Weigh Tronix 2007 Avery Weigh Tronix P Upload and Download PLU Purpose Allows new PLUs to be created or tra
2. appended to command enables data entry Response ACK indicator is in normal weighing mode NAK indicator is terminal mode Mode Normal weighing mode Indicators All Return to Top Level Soft Key Purpose Displays the top level soft keys function keys when the indicator receives this command Command lt STX gt JO lt ETX gt Response ACK indicator is in normal weighing mode NAK indicator is terminal mode Mode Normal weighing mode Indicators All Avery Weigh Tronix 2007 Version 3 0 Issued October 2007 Page 12 of 32 Industrial Indicators Terminal Mode Serial Communications Avery Weigh Tronix mede aa 3 2 3 3 2 4 3 2 5 Restart Indicator Purpose Forces the indicator to perform a warm start no memory test Command lt STX gt RS lt ETX gt Response ACK Mode Anytime Indicators All Remote Print Request Purpose Simulates the operator pressing the print key The transmitted string will be that of the current functional mode that is check weighing string and interlocks will be checked Command lt STX gt PR lt ETX gt Response Formatted print string If the print interlocks are not met then there will be no response L NOTE The indicator must not display an error message Mode Normal weighing mode Indicators All Suppress Soft Keys Purpose To simplify the display and give greater remote control
3. weigh only T to 8 or set bit 7 and 0 128 ASCII weight Response ACK command processed plus optional target value in ASCII NAK invalid parameter received command not processed Mode Any mode Indicators All Avery Weigh Tronix 2007 Version 3 0 Issued October 2007 Page 23 of 32 Avery Weigh Tronix mmm Industrial Indicators Terminal Mode Serial Communications 3 4 12 Recipe Target Weight Values Command lt STX gt ST plus data lt ETX gt Data Byte 1 Get or Set 0 load new value 1 sends current value Byte 2 Scale ID Not used currently set to 0 0 scale 1 1 scale 2 Byte 3 Unit Not used currently set to 0 0 primary 1 secondary 2 custom Byte 4 Ingredient ID weigh only 1 to 8 or set bit 7 and 0 128 NOTE This is not the alarm number but unfortunately but the nth weight based alarm ASCII weight Response ACK command processed plus optional target value in ASCII NAK invalid parameter received command not processed Mode Any mode Indicators All 3 4 13 Select Recipe Command lt STX gt SR plus data lt ETX gt Byte 1 Get or Send 0 Load new value 1 Send current value Byte 2 amp 3 optional Recipe ID 0 9 Response ACK command processed recipe number in ASCII on Send NAK invalid parameter received command not processed Mode Any mode Indicators E11xx and
4. 3 records older than 12 months Response Sub Command 1 4 ACK lt STX gt ASCII lt ET X gt NAK Sub Command 2 3 ACK lt STX gt stransaction record lt ET X gt NAK Sub Command 5 ACK lt STX gt record lt ETX gt OR lt ETX gt multiple records NAK Sub Command 6 ACK NAK Mode Normal Indicators E11xx and E12xx Rev 2 Avery Weigh Tronix 2007 Version 3 0 Issued October 2007 Page 29 of 32 Industrial Indicators Terminal Mode Serial Communications Avery Weigh Tronix mmm ZL NOTE The format of a transaction record shall be as shown below m Idid y lylylyl c fe fe fe fe fe I isl w we wt wy we w wiw uju sat sat sat sat sat sat sat sat pt pt pt pt pt pt pt pt crc m minutes h hours 24 hour d day m month y year 2 digit year C consecutive number Ss scale id 1 2 3 W weight note always uses decimal point if present u units sat semi Auto or Free tare pt keyboard entered or stored tare t tare 0 no tare 1 free tare 2 stored tare or 3 stored and free tare crc checksum 0 valid 1 invalid Avery Weigh Tronix 2007 Version 3 0 Issued October 2007 Page 30 of 32 Industrial Indicators Terminal Mode Serial Communication
5. Purpose The indicator sends the current active PLU number Command lt STX gt OP lt ET X gt Response ACK current active PLU number in ASCII NAK indicator in terminal mode or no PLU is active Mode Normal weighing mode Indicators All 3 4 3 Activate PLU Purpose Activates a specified PLU The PLU may be identified either by name or number L NOTE The indicator is to behave in the same way as it would if the PLU was enabled from the keyboard Command lt STX gt APplu identifier lt ETX gt Response ACK command accepted NAK Mode Normal Indicators All Avery Weigh Tronix 2007 Version 3 0 Issued October 2007 Page 18 of 32 Industrial Indicators Terminal Mode Serial Communications Avery Weigh Tronix ee Aa 3 4 4 Check Weigh Low Value use in Limits mode Purpose Uploads and downloads the check weigh low target value of the specified platform Command lt STX gt CL plus data lt ETX gt Data Byte 1 Get or Set 0 load new value 1 sends current value Byte 2 Scale ID 0 scale 1 1 scale 2 Byte 3 Unit 0 primary 1 secondary 2 custom ASCII weight Response ACK command processed plus optional target value in ASCII NAK invalid parameter received command not processed Mode Any mode Indicators All 3 4 5 Check Weigh High Value use in Limits mode Purpose Uploads and downloads the chec
6. trip 2 char 3 Automatic inflight compensation trip 3 char 4 Automatic inflight compensation trip 4 Avery Weigh Tronix 2007 Version 3 0 Issued October 2007 Page 31 of 32 Avery Weigh Tronix A Industrial Indicators Terminal Mode Serial Communications 4 2 Option names COUNT FILL CHECK BRIDGE BREAD AV WT PACK Avery Weigh Tronix 2007 Version 3 0 Issued October 2007 Page 32 of 32
7. Avery Weigh Tronix pa Industrial Indicators Terminal Mode Serial Communications Loadstar L215 amp L225 Evolution E1105 E1110 E1205 amp E1210 English 76102 743 Issue 3 October 2007 LERE OMAN DION OK DEUIA VLOU SOON DUOT DUNDA UIII ITN 2007 Avery Weigh Tronix LCC All rights reserved The information contained herein is the property of Avery Weigh Tronix LCC and is supplied without liability for errors or omissions No part may be reproduced or used except as authorized by contract or other written permission The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied Trademarks and acknowledgements Avery Avery Berkel and Avery Weigh Tronix are registered trademarks in certain jurisdictions and owned and registered by companies within the Avery Weigh Tronix Group All brands and product names used within this document are trademarks or registered trademarks of their respective holders IMPORTANT When programming or configuring the equipment you must ensure that you comply with all relevant standards and legislation The example settings in this book may not be legal for trade with the public Industrial Indicators Terminal Mode Serial Communications Avery Weigh Tronix Table of contents 1 SEGE RA AE E REE BE RES Pe eee re Peep EERE eer 6 Ziv Operation E DE ee eel dead aac Pa Ee 7 2 1 Entry into and exit from dumb te
8. E12xx 3 4 14 Recipe Active Command lt STX gt RA lt ETX gt Response ACK Recipe in progress NAK Recipe not active Mode Normal Indicators E11xx and E12xx Avery Weigh Tronix 2007 Version 3 0 Issued October 2007 Page 24 of 32 Industrial Indicators Terminal Mode Serial Communications Avery Weigh Tronix 3 4 15 Recipe Control Command lt STX gt RC data lt ETX gt Data Byte 1 Recipe Action 1 ABORT 2 START 3 PAUSE 4 RESUME 5 RESET Response ACK command processed NAK invalid parameter received command not processed Mode Normal Indicators E11xx and E12xx 3 4 16 Recipe Info Purpose Formats a string containing recipe name and ingredient information Command lt STX gt RI data lt ETX gt Data r recipe number R recipe name i ingredient number l ingredient name ASCII chars just copied as is into output string Response ACK lt STX gt ASCII string lt ETX gt NAK invalid parameter received command not processed Mode Normal Indicators E11xx and E12xx Avery Weigh Tronix 2007 Version 3 0 Issued October 2007 Page 25 of 32 Industrial Indicators Terminal Mode Serial Communications 3 4 17 Alarm Target Avery Weigh Tronix die ee Command lt STX gt AW data lt ETX gt Data Byte 1 Get or Set 0 load new value 1 sends cur
9. a soft key in normal weighing mode without having suppressed the standard soft keys Mode Any mode Indicators All except E11xx Version 3 0 Issued October 2007 Page 10 of 32 Avery Weigh Tronix ee a Industrial Indicators Terminal Mode Serial Communications 3 1 9 Update the Weight Purpose Forces the indicator to update the weight display This command was put in for balance compatibility Command lt STX gt FW lt ETX gt Response ACK command processed NAK the indicator is in terminal mode Mode Terminal mode Indicators All 3 1 10 Display the Weight Command lt STX gt IW plus data lt ETX gt Char 1 1 show weight Char 2 8 disable weight leaving it showing Char 2 4 permanent freezes weight same as above Optional char 3 1 show weight in current active format 2 show platform 1 weight in large format 4 show platform 2 weight in large format 8 show dual weight format Optional char 4 1 show platform 1 weight in medium format 2 show platform 2 weight in medium format Response ACK command processed NAK the indicator isn t in terminal mode Mode Terminal mode Indicators All ZL NOTE To clear the screen send Freeze and then IW18 3 1 11 Line Draw Graphics Purpose Allows the remote device to plot lines on the indicator display The display is 240 64 the bottom left of the d
10. and to interrogate the terminal mode status Dumb terminal mode operation In the dumb terminal mode the indicator functions as a dumb terminal with commands to allow remote control of the display Screen formatting commands are provided to allow cursor positioning clearing of the LCD display screen and the display of the following e Filling bars e Check weighing bars e Weight e Count e Tare e Creating of soft key It is the responsibility of the controlling remote device to ensure that any over lapping of text and graphics are handled correctly When the indicator is operating in terminal mode any keys pressed will be transmitted out on the serial port with the remote PC being responsible for handling ANY resulting actions Terminal control in normal weighing mode In normal weighing mode the display formatting capabilities of the remote device will be limited to control of the indicator soft keys The remote device can suppress the standard soft keys and replace them with dummy soft keys These dummy keys have no functionality other than to transmit the label of the pressed soft key down to the remote device Avery Weigh Tronix 2007 Version 3 0 Issued October 2007 Page 7 of 32 Industrial Indicators Terminal Mode Serial Communications Avery Weigh Tronix P 3 Supported commands All commands are prefixed by an STX and suffixed by an ETX All data contained between the STX and ETX must be
11. cators All 3 2 7 Direct I O Control Purpose Allows a remote device direct access to the indicators I O However the command will function in both normal weighing and in terminal mode if the indicator is running trips then the outcome of trying to control the state of the outputs will be uncertain Command sSTX IO action optional data lt ETX gt Action 0 Current IO status sent Action 1 external device controls the trip outputs Byte 1 A P Byte 2 A P Advanced only Byte 3 A P Byte 4 A P Response ACK command accepted optional data NAK Optional data Byte 1 A P Four bits Byte 2 A P Four bits Advanced only Byte 3 A P Four bits Byte 4 A P Four bits Mode Any mode Indicators All Avery Weigh Tronix 2007 Version 3 0 Issued October 2007 Page 14 of 32 Avery Weigh Tronix ae I Industrial Indicators Terminal Mode Serial Communications 3 2 8 Enable and Disable Indicator Function Purpose Enables a remote device to control the indicator mode of operation without having to resort to keyboard emulation Command lt STX gt OE data lt ETX gt Char 1 O disable or 1 enables Name of option Response ACK command accepted NAK if indicator is in terminal mode or invalid data Mode Normal weighing mode In
12. dicators All L NOTE Refer to the Appendix for a list of functions 3 2 9 Set Time and Date Purpose Allows the real time clock to be set This function operates under the principles of GIGO Command lt STX gt TD time and date in ASCII lt ETX gt Hour high hour low min high min low sec s high sec s low month high month low day high day low year high year low For example 11 39 24 19 10 98 Response ACK command processed NAK RTC wasn t updated Mode Any mode Indicators All 3 2 10 Keyboard Enable and Disable Purpose Allows a keyboard to be enabled or disabled Command lt STX gt KA data lt ETX gt Byte 1 0 disable 1 enable keyboard Response ACK NAK Mode Any mode Indicators All Avery Weigh Tronix 2007 Version 3 0 Issued October 2007 Page 15 of 32 Avery Weigh Tronix Industrial Indicators Terminal Mode Serial Communications A 3 3 Indicator weight and tare commands 3 3 1 Get Weight Purpose Causes the indicator to send the current weight the string will be that formatted in the communications channel Indicator interlocks are not checked Command lt STX gt PP lt ETX gt Response Formatted weight string Mode Anytime Indicators All 3 3 2 Zero Request Purpose Allows the remote device to re zero the indicator The indicator will acknowledge that it has received the command but t
13. e use in Tol mode Purpose Uploads downloads the check weigh target value of specified platform Command lt STX gt TL plus data lt ETX gt Data Byte 1 Get or Set 0 load new value 1 sends current value Byte 2 Scale ID 0 scale 1 1 scale 2 Byte 3 Unit 0 primary 1 secondary 2 custom ASCII weight Response ACK command processed plus optional target value in ASCII NAK invalid parameter received command not processed Mode Any mode Indicators All 3 4 8 Check Weigh Target Hi Tolerance use in Tol mode Purpose Uploads and downloads the check weigh target value of the specified platform Command lt STX gt CL plus data lt ETX gt Data Byte 1 Get or Set 0 load new value 1 sends current value Byte 2 Scale ID 0 scale 1 1 scale 2 Byte 3 Unit 0 primary 1 secondary 2 custom ASCII weight Response ACK command processed plus optional target value in ASCII NAK invalid parameter received command not processed Mode Any mode Indicators All Avery Weigh Tronix 2007 Version 3 0 Issued October 2007 Page 21 of 32 Industrial Indicators Terminal Mode Serial Communications Avery Weigh Tronix P 3 4 9 Count Piece Weight Value Purpose Uploads and downloads the piece weights to be used in counting Command lt STX gt CP plus data lt ETX
14. ent distribution list Name Job Title or Role Agreement Information Document version control Date of Issue of Short Description of the Main Author of Issue Document Modifications in each Issue Document Nov 04 2 0 Issue 2 0 issued Brian Nettleingham Oct 07 3 0 Issue 3 0 issued Brian Nettleingham Record of changes in this version Date of Change Description of Change Page No Avery Weigh Tronix 2007 Version 3 0 Issued October 2007 Page 5 of 32 Avery Weigh Tronix ye Industrial Indicators Terminal Mode Serial Communications 1 Scope This document describes the serial commands of the terminal mode functionality which have been added to the Loadstar L215 amp L225 and Evolution E1105 E1110 E1205 amp E1210 indicators The commands allow the indicators to interface with the PC application Avery Weigh Tronix 2007 Version 3 0 Issued October 2007 Page 6 of 32 Industrial Indicators Terminal Mode Serial Communications Avery Weigh Tronix 2 2 1 2 2 2 3 Operation The indicator is capable of providing support for one terminal channel although any of the communications channels can be used Entry into and exit from dumb terminal mode Serial commands are provided to allow the indicator to enter into and exit from the terminal mode This also includes a comm
15. ess SOM Keys ER dense ee EE EE eg ae eke DR ee 13 3 2 6 Routing Data Streams 4 EER cen RA EG n 14 3 2 7 Direct O EonOl EE EA EA GE 14 3 2 8 Enable and Disable Indicator FunCUON esse ee ee ee 15 3 2 9 Set Time and Date ESE ESE GE EE SR ERK ER Re SR ke eie 15 3 2 10 Keyboard Enable and Disable iese ee ee ee ee ee 15 3 3 Indicator weight and tare commandsS iese ee ee Re ee ee 16 3 3 1 Get Wed je Se EERS EED EE 16 3 3 2 Zer Reduest es ie EE hus oo anaes id eee 16 Avery Weigh Tronix 2007 Version 3 0 Issued October 2007 Page 3 of 32 Avery Weigh Tronix ye Industrial Indicators Terminal Mode Serial Communications 3339 sat TARO Value eked siete hey sc RA RE valine eg E ee Ee ge R 16 3 3 4 Clear Current Semi Auto Tare eie se ee ee RA dd ee 17 3 39 Set Tare Val per OR N 2 17 3 3 6 Set clear Preset T are vies scceressisetceientate neentnatgeeahtiassanenendees sd 17 3 4 Indicator application eommands iis Bee Ee SEGE SESSE EES Ep EDE ee 18 3 4 1 Current Active Function se RE ee EER eN ge 18 3 4 2 Current Active PLU i ss SE RE NE N EE Ge Ge ake 18 3 4 9 Activate PLU se ses NR SG en tae nein ais 18 3 4 4 Check Weigh Low Value use in Limits mode 05 19 3 4 5 Check Weigh High Value use in Limits mode 00 19 3 4 6 Check Weigh Target Accept use in Tol mode e 20 3 4 7 Check Weigh Target Lo Tolerance use in Tol mode 21 3 4 8 Check Weigh Ta
16. greater than 1F hex Any data less than this must have 20 hex added to it and be prefixed by the SUB 1A Hex character Each serial command is identified by a unique two byte identifier The terminal mode commands support the following activities Entry and exit from terminal mode Dumb terminal mode including screen formatting commands Routing received text messages to specified serial ports Uploading and downloading PLUs Facility for uploading and downloading indicator function settings such as counting Suppression and assignment of soft keys in normal weighing mode 3 1 Display and formatting commands 3 1 1 Enter Terminal Mode Purpose Clears the display and passes indicator control to the computer All key presses are to be sent to the computer for action Command lt STX gt GT lt ETX gt Response ACK indicator now in dumb terminal mode NAK indicator was already in dumb terminal mode Mode Normal weighing mode Indicators All L NOTE E11xx does not support terminal 3 1 2 Exit Terminal Mode Purpose Exits dumb terminal mode restoring control back to the indicator The display is to be restored to normal Command lt STX gt ET lt ETX gt Response ACK indicator now in normal weighing mode displays restored NAK indicator was not in dumb terminal mode Mode Terminal mode Indicators All Avery Weigh Tronix 2007 Version 3 0 Issued October 2007 Page 8 of 32
17. gt Data Byte 1 Get or Set 0 load new value 1 sends current value Byte 2 Scale ID 0 scale 1 1 scale 2 Byte 3 Unit 0 primary 1 secondary 2 custom ASCII weight Response ACK command processed plus optional target value in ASCII NAK invalid parameter received command not processed Mode Any mode Indicators All Avery Weigh Tronix 2007 Version 3 0 Issued October 2007 Page 22 of 32 Industrial Indicators Terminal Mode Serial Communications Avery Weigh Tronix ede Ge ee 3 4 10 Count Target Value Purpose Uploads and downloads the count target Command lt STX gt TC plus data lt ETX gt Data Byte 1 Get or Set 0 load new value 1 sends current value Byte 2 Scale ID 0 scale 1 1 scale 2 Byte 3 Unit 0 primary 1 secondary 2 custom ASCII weight Response ACK command processed plus optional target value in ASCII NAK invalid parameter received command not processed Mode Any mode Indicators All 3 4 11 Recipe Weight Compensation Values Command lt STX gt TI plus data lt ETX gt Data Byte 1 Get or Set 0 load new value 1 sends current value Byte 2 Scale ID Not used currently set to 0 0 scale 1 1 scale 2 Byte 3 Unit Not used currently set to 0 0 primary 1 secondary 2 custom Byte 4 Ingredient ID
18. his does not mean that the indicator has successfully processed the request It is the responsibility of the remote device to check that the weight is actually zero Command lt STX gt ZEdata lt ETX gt Char 1 0 platform 1 1 platform 2 Response ACK command accepted Mode Any Indicators All 3 3 3 Sat Tare Value Purpose Causes the current semi auto tare value to be transmitted With no additional parameters added to the command it is compatible with balance but due to the indicator have multiple platforms and dual grads additional parameters are required Command lt STX gt CT optional lt ETX gt Optional If there is no optional data then the SAT value sent is for the active scale and units Byte 1 Scale 0 1 Byte 2 Units 0 primary units 1 secondary units 2 custom Avery Weigh Tronix 2007 Version 3 0 Issued October 2007 Page 16 of 32 Industrial Indicators Terminal Mode Serial Communications Avery Weigh Tronix 3 34 3 3 5 3 3 6 Response ACK formatted print string NAK if parameters invalid Mode Anytime Indicators All Clear Current Semi Auto Tare Purpose Clears the semi auto tare of the currently active platform Command lt STX gt RT lt ETX gt Response ACK Mode Anytime Indicators All Set Tare Value Purpose Causes the current semi auto tare value t
19. isplay is assumed to be point 0 0 and the top right 239 63 Multiple line may be defined within a single line Command lt STX gt DL data lt ETX gt Char 1 Style 0 o clear line 1 to draw line Char 2 13 are co ordinates x y that specify the two line points Up to 10 lines can be configured in a single command Response ACK NAK Mode Any Indicators All except E1105 Avery Weigh Tronix 2007 Version 3 0 Issued October 2007 Page 11 of 32 Avery Weigh Tronix lee Industrial Indicators Terminal Mode Serial Communications 3 1 12 Data Entry Title Command lt STX gt WT text lt ETX gt text pre fixes the data entry text with a string Response ACK success text is accepted NAK Mode Any Indicators All except E11xx 3 1 13 Password Text Entry Purpose When set keys typed in by the user are displayed as while the key is still sent in its normal form Command lt STX gt PA x lt ETX gt Byte x 0 normal text 1 display entered text as text pre fixes the data entry text with a string Response ACK NAK Mode Terminal Indicators E12xx Indicator control commands Enable and Disable Data Entry Purpose Toggles the data entry permission in normal weighing mode Initial data entry is enabled Command lt STX gt DW lt ETX gt No data appended to command disables data entry 1
20. k weigh target value of the specified platform Command lt STX gt CH plus data lt ETX gt Data Get or Set 0 load new value 1 sends current value Byte 1 Byte 2 Scale ID 0 scale 1 1 scale 2 Byte 3 Unit 0 primary 1 secondary 2 custom ASCII weight Avery Weigh Tronix 2007 Version 3 0 Issued October 2007 Page 19 of 32 Avery Weigh Tronix A Industrial Indicators Terminal Mode Serial Communications Response ACK command processed plus optional target value in ASCII NAK invalid parameter received command not processed Mode Any mode Indicators All 3 4 6 Check Weigh Target Accept use in Tol mode Purpose Uploads and downloads the check weigh target value of the specified platform Command lt STX gt TA plus data lt ETX gt Data Byte 1 Get or Set 0 load new value 1 sends current value Byte 2 Scale ID 0 scale 1 1 scale 2 Byte 3 Unit 0 primary 1 secondary 2 custom ASCII weight Response ACK command processed plus optional target value in ASCII NAK invalid parameter received command not processed Mode Any mode Indicators All Avery Weigh Tronix 2007 Version 3 0 Issued October 2007 Page 20 of 32 Avery Weigh Tronix Industrial Indicators Terminal Mode Serial Communications 3 4 7 Check Weigh Target Lo Toleranc
21. nsmits current PLU settings Command lt STX gt PL 0 ASCII value to Upload 1 to Download lt ETX gt Response ACK data NAK invalid PLU Mode Any time Indicators L2xx L NOTE Refer to Appendix A for format of PLU data Destroy Terminal Mode Soft Keys Purpose Enables soft keys 1 to 5 to be destroyed and clears the assigned a label Sending the command with no additional parameters will cause all soft keys to be destroyed However if by appending an additional optional parameter value ranging from 1 to 5 then a specified soft key can be destroyed Command lt STX gt DK Optional soft key lt ETX gt Response ACK command processed NAK invalid option specified Mode Any time Indicators All except E11xx Create Soft Key Purpose Enables soft keys 1 to 5 to be created and assigned a label Soft keys can be assigned in dumb terminal mode and even in normal weighing mode as long as the standard soft keys have been suppressed When using assigned soft keys in normal weighing mode pressing them causes no action to take place other than the soft key label being sent down to any serial channel configured for terminal emulation In terminal mode the soft key number will be sent binary 1 to 5 Command lt STX gt AK Six char label upper case lt ETX gt Response ACK command processed NAK invalid either incorrect label position or attempting to assign
22. o be transmitted With no additional parameters added to the command it is compatible with balance but due to the indicator have multiple platforms and dual grads additional parameters are required Command lt STX gt TT optional lt ETX gt Optional If there is no optional data then indicator attempt to perform a SAT tare on the active scale If there is data it tries to set a preset tare based on this value Response ACK did a tare NAK Mode Any time Indicators All Set clear Preset Tare Purpose Allows the preset tare for the currently active platform to be set or cleared Command lt STX gt PT lt ETX gt perform semi auto tare lt STX gt PT lt ETX gt clear active tares lt STX gt PT ASCII tare value lt ETX gt perform preset tare Response ACK command processed NAK invalid parameter Mode Any time Indicators All Avery Weigh Tronix 2007 Version 3 0 Issued October 2007 Page 17 of 32 Avery Weigh Tronix Industrial Indicators Terminal Mode Serial Communications a 3 4 Indicator application commands 3 4 1 Current Active Function Purpose Causes the name of the current active function to be sent Command lt STX gt OO lt ETX gt Response ACK formatted print string NAK if indicator is in terminal mode Mode Normal weighing mode Indicators All L NOTE Refer to the Appendix for a list of functions 3 4 2 Current Active PLU
23. processed plus optional target value in ASCII NAK invalid parameter received command not processed Mode Normal Indicators All 3 4 23 User Field Titles Purpose This command allows access to the user field title strings There are 20 of these strings each 25 characters in length Command lt STX gt UFdata lt ETX gt Char 1 0 load new value 1 sends current value Char 2 amp 3 Title number in ASCII ASCII string Response ACK command processed plus optional string in ASCII NAK invalid parameter received command not processed Mode Normal Indicators All except E1105 Avery Weigh Tronix 2007 Version 3 0 Issued October 2007 Page 28 of 32 Industrial Indicators Terminal Mode Serial Communications Avery Weigh Tronix 3 4 24 Query Transaction Log Purpose Interface for querying the indicator transaction log stored on the external memory casd Command lt STX gt ODdata lt ETX gt data Byte 1 Sub Command 1 get total number of transactions 2 get first transaction 3 get last transaction 4 get number of transactions meeting this query 5 get transaction meeting this query 6 delete transaction records Sub Command 1 3 No additional data required Sub command 4 5 See record below Sub Command 6 Byte 2 define records to be deleted 1 records older than 3 months 2 records older than 6 months
24. rent value Byte 2 Scale ID Not used currently set to 0 0 scale 1 1 scale 2 Byte 3 Unit Not used currently set to 0 0 primary 1 secondary 2 custom Byte 4 Alarm ID weigh only T to 8 or set bit 7 and 0 128 Note this is not the alarm number but unfortunately but the nth weight based alarm ASCII Weight Response ACK lt STX gt ASCIl Weight lt ETX gt Send only NAK invalid parameter received command not processed Mode Normal Indicators E11xx and E12xx 3 4 18 Conversion Factor Value Purpose Uploads and downloads a conversion factor Command lt STX gt CF plus data lt ETX gt Byte 1 Get or Set 0 load new value 1 sends current value conversion factor in ASCII Response ACK command processed plus optional target value in ASCII NAK invalid parameter received command not processed Mode Any mode Indicators All except E1105 Avery Weigh Tronix 2007 Version 3 0 Issued October 2007 Page 26 of 32 Industrial Indicators Terminal M Avery Weigh Tronix ode Serial Communications 3 4 19 Conversion Factor Units Purpose Uploads and downloads the conversion factor units Command lt STX gt CU plus data lt ETX gt Byte 1 Get or Send 0 Load new value 1 Send current value Conversion factor units in ASCII 1 to 8 Response ACK command processed plus op
25. rget Hi Tolerance use in Tol mode 21 3 4 9 Count Piece Weight Value see ee RA RR ee 22 3 4 10 Count Target Values sis ER eg ee Boe GR e 23 3 4 11 Recipe Weight Compensation Values sesse ee 23 3 4 12 Recipe Target Weight Values ees ee Re ee ee AR Rae 24 3 4 13 ede MR EE HE EE 24 3 4 14 Recipe AFVEE Ee RE RE EE RE ee Se ER ese 24 34615 Recipe EontrOli EE test as RES ASE ee doe 25 SAGO Recipe lie EE EN DE NE N ee Ge be ey Ges 25 dal Alarm Target osse N ge SE ge El De AS Ee 26 3 4 18 Conversion Factor Value uie ee ee AA RA AA ee 26 3 4 19 Conversion Factor Units ii EE SEER Ee See GREG de we eke ee Ee 27 3 4 20 Computer LINK ies es EN EA ER ete GE ee EK GR EK SE RR beg ER els 27 3 4 21 Pack Run Target Es BG AE ee ee DE 27 3 4 22 Pack Run Minimum Weight see ees ee ee ee Re ee ee Ee ke ee 28 3 4 23 User Field Titles ss ER kee RE Nee de ee ede Sa A 28 3 4 24 Query Transaction Log ee ee ee ee Re ee 29 4 PRPS I es si EE Ed AE de Se DE ER Ne N de 31 4 1 Format f PLU Gate os Es Se a Bee ee ei 31 4 2 OPEN HARMSE LE ED ES RE RD eee aa ane 32 Avery Weigh Tronix 2007 Version 3 0 Issued October 2007 Page 4 of 32 Industrial Indicators Terminal Mode Serial Communications Avery Weigh Tronix Title of Document Industrial Indicators Terminal Mode Serial Communications Loadstar L215 amp L225 Evolution E1105 E1110 E1205 amp E1210 Docum
26. rminal mode esse ee ee ee 7 2 2 Dumb terminal mode operation si EE ee Ee Ed be se N AE ESE Ge es en cee 7 2 3 Terminal control in normal weighing mode esse ee Re ee ee 7 3 Supported 6rmnands EE RE ER ER ee eN ve ee ee eg tee n ge Ee 8 3 1 Display and formatting COMMANAS ees ee ee ee RR Re ee ee ee ee 8 3 1 1 Enter Terminal Mode oe ee Bee ES EE EE Eg aa 8 3 1 2 Exit Terminal Mode RE ER ER SEER ER EED aint Ee Dee se 8 3 1 3 Enquire Terminal Mode iis ee Re ee ee ee ee 9 3 1 4 Clear Display sisie ESE KEER KEER EER a EER RE SE n 9 3 1 5 Display Text Message iese Re ee ee ee Ee ee ee ee ee ee ed 9 3 1 6 Upload and Download PLU ese ee Re Ee Ee ee EE ee 10 3 1 7 Destroy Terminal Mode Soft KeyS ie ee ee ee ee 10 3 1 8 Create Soft Key SEERDE tied ee eee eee 10 3 1 9 Update the Weight ei RE KEER REEN cia nie dager Ee 11 3 1 10 Display the WIGHT EERS GE DEE Ee Rd det ede Re NE gee 11 3 1 11 Line Draw Graphics Ee REEN Ke EE ERGER ER Ge BR ee ER GE DRR Ee EE 11 3 1 12 Data Entry dle ses BR RE DE ED GE 12 3 0 Password Test ER es Ee Es atin eke sie Se se Ie 12 3 2 Indicator control commandS esse ee AE Re Ge Re ke ee ee 12 3 2 1 Enable and Disable Data Entry 12 3 2 2 Return to Top Level Soft KeY see esse ee ee AA ee AA ee 12 3 2 35 RestartindiGEtOF iese RES EEER rsin 13 3 2 4 Remote Print Request ica ES IE N EDGE Ge Ee EE ea Se RE Wy DE 13 3 2 5 Suppr
27. s Avery Weigh Tronix mede aa 4 Appendix 4 1 Format of PLU data L NOTE Only applicable to L225 Upload and Download PLU data char 1 PLU associated platform char 3 PLU number char 20 Part number field char 20 PLU description field char 20 Scribble field char 8 PLU type see 4 2 char 6 PLU units char 12 PLU sub total char 12 PLU grand total char 6 PLU sub total transaction counter char 6 PLU grand total transaction counter char 1 1 or 0 Wipe sub total char 1 1 or 0 Wipe grand total char 2 Associated tare store char 6 Tare value held in PLU char 2 Conversion factor units units go 1 to 10 as configured in supervisor mode char 6 Conversion factor char 4 Packing run size char 6 Packing run minimum weight char 1 0 or 1 product listing disable enable char 8 Date on which the PLU was created in a format of dd mm yy Years less than 92 are assumed to be for the next century L NOTE Do not create PLUS with future dates Eight blocks of seven characters as below Store No Count Checkweigher Fill Trips 1 Pce wt Low accept Low display Trip 1 2 Limit High accept Low OK Trip 2 3 Samp size Target Trip 3 4 High OK Trip 4 5 Comp 1 6 Comp 2 7 Comp 3 8 Comp 4 char 1 Automatic inflight compensation trip 1 char 2 Automatic inflight compensation
28. this command is to be added to allow a remote device to hide the standard soft keys This command is intended for use with the AK command which allows dummy soft keys to be assigned When the soft key is pressed the indicator takes no action except to send the keys label name to the remote device channel that suppressed the soft keys in the first place Command lt STX gt HS action lt ETX gt action 0 releases soft keys 1 suppresses soft keys Response ACK command accepted NAK invalid parameter received command not processed Mode Normal weighing mode Indicators All Avery Weigh Tronix 2007 Version 3 0 Issued October 2007 Page 13 of 32 Avery Weigh Tronix dm ee Industrial Indicators Terminal Mode Serial Communications 3 2 6 Routing Data Streams Purpose Allows data to receive on one channel and transfer to another The data to be routed must be prefixed by an STX and suffixed by an ETX and can be no more than 190 characters in length All data contained between the STX and ETX must be greater than 1F hex any data less than this must have 20 hex added to it and be prefixed by the SUB 1A Hex character Command lt STX gt DS plus data lt ETX gt char 1 0 Internal printer 1 Comm channel 1 2 Comm channel 2 3 Comm channel 3 Response ACK command accepted NAK invalid parameter received command not processed Mode Any mode Indi
29. tional target value in ASCII NAK invalid parameter received command not processed Mode Any mode Indicators All except E1105 3 4 20 Computer Link Purpose Allows terminal mode to support the computer link commands as defined in the service manual ZL NOTE lt SUB gt characters will be needed Command lt STX gt XXterminal command lt ETX gt Response ACK command accepted computer link response NAK computer link command not found Mode Normal Indicators All 3 4 21 Pack Run Target Command lt STX gt PV data lt ETX gt Data Byte 1 Get or Set 0 load new value 1 sends current value Byte 2 Scale ID 0 scale 1 1 scale 2 Byte 3 Unit 0 primary 1 secondary 2 custom ASCII weight Response ACK command processed plus optional target value in ASCII NAK invalid parameter received command not processed Mode Normal Indicators All Avery Weigh Tronix 2007 Version 3 0 Issued October 2007 Page 27 of 32 Industrial Indicators Terminal Mode Serial Communications Avery Weigh Tronix A 3 4 22 Pack Run Minimum Weight Command lt STX gt PM data lt ETX gt Data Byte 1 Get or Set 0 load new value 1 sends current value Byte 2 Scale ID 0 scale 1 1 scale 2 Byte 3 Unit 0 primary 1 secondary 2 custom ASCII weight Response ACK command

Download Pdf Manuals