Home

Keysight 16089A, B, C, D Kelvin/Alligator Clip Leads

image

Contents

1. Figure 4 1 Kelvin Clip Connections Test Lead 27 Table 4 4 Table 4 5 Service Replaceable Parts 16089D Replaceable Parts 16089D Replaceable Parts Keysight Part Number Quantity Description 16089 60004 1 Test Leads 16089 04004 1 Cover Top 0515 0914 2 Screw Flat Head M3X0 5 L6 0340 1085 2 Insulator Alligator Clip Red 0340 1086 1 Insulator Alligator Clip Black 1400 1252 4 Alligator Clip 7121 2696 2 Wire Marker V 16089 01201 1 Short Bar 0515 1550 2 Screw 1 The whole unit Keysight internal only part Table 4 5 shows the correspondence between the Alligator Clips and the Cables Clip and Cable Correspondence Alligator Clip Color Cable Color Marker Red Orange V Red Red Black Gray V Black Black 28 This information is subject to change without notice Keysight Technologies 1991 2000 2001 2002 2010 2015 Edition 6 May 2015 30 x 89 900 www keysight com KEYSIGHT Ml TECHNOLOGIES
2. DO NOT Operate In An Explosive Atmosphere Do not operate the instrument in the presence of inflammable gasses or fumes Operation of any electrical instrument in such an environment constitutes a safety hazard Keep Away from Live Circuits Operating personnel must not remove instrument covers Component replacement and internal adjustments must be made by qualified maintenance personnel Do not replace components with the power cable connected Under certain conditions dangerous voltage levels may remain even after the power cable has been disconnected To avoid injuries always disconnect the power and discharge circuits before touching them DO NOT Service or Adjust the Instrument Alone Do not attempt internal service or adjustment unless another person capable of rendering first aid and resuscitation is present To avoid the danger of introducing additional hazards do not install substitute parts or perform unauthorized modifications to the instrument Return the instrument to a Keysight Technologies Sales and Service Office for service and repair to ensure that safety features are maintained in operational condition Dangerous Procedure Warnings Warning such as the example below precede potentially dangerous procedures throughput this manual Instructions contained in the warnings must be followed Dangerous voltages level capable of causing death are present in this instrument Use extreme caution when handl
3. Table 2 3 Contents of 16089C Description Keysight Part Number Quantity Kelvin Clip Leads 16089 600031 1 Operation and Service Manual 16089 90030 1 1 Keysight internal only part number 2 Operation and Service Manual is not shown in Figure 2 3 Preparation for Use Initial Inspection 16089D Figure 2 4 16089D Product Overview amp East r ps Py Table 2 4 Contents of 16089D Description Keysight Part Number Quantity Kelvin Clip Leads 16089 60004 1 Operation and Service Manual 16089 90030 1 1 Keysight internal only part number 2 Operation and Service Manual is not shown in Figure 2 4 Preparation for Use Ambient Environmental Considerations Ambient Environmental Considerations Operating and Storage The 16089A B C D must be operated within an ambient temperature range of 0 C to 55 C and relative humidity up to 95 at 40 C non condensing The 16089A B C D may be stored within a temperature range of 40 C to 70 C and at a relative humidity of up to 95 at 40 C non condensing Connecting the Test Leads for Use Figure 2 5 Connecting the Test Leads UNKNOWN terminals Turn levers right of Instruments AA om Insert Four terminal pair BNC terminals of test leads Step 1 Step 2 Packaging the Test Leads If shipment to a Keysight Technologies service center is required each test lead set should be repackaged using the original factory packaging materials Alternatively comparable
4. 4 Connect the component to be tested into the test clips When 16089D is used connect the test clips to the DUT correctly as follows e Connect all test clips to the DUT Connect the same color test clips to the same terminal of the DUT e Connect the Hoot and Lpot clips marked V closer to the DUT than Heur and Leur clips Figure 3 5 also shows how to connect a DUT using the alligator clips of thel6089D Connecting the DUT to the16089D Hcur Hpot Lpot Lcur vV markers ae o no N ain igator igator Clip DUT Clip 24 Service Introduction 16089A B C D Operation and Service Manual 4 Service Introduction This chapter gives replaceable parts information for the 16089A 16089B 16089C and 16089D Replaceable Parts Table 4 1 Table 4 2 Table 4 3 and Table 4 4 list the replaceable parts for the 16089A B C and D respectively Figure 4 1 shows the connection from the cable to the clip assembly of the 16089C The parts listed can be ordered from your nearest Keysight Technologies office Ordering information should include the Keysight part number and the quantity required KEYSIGHT TECHNOLOGIES 25 Table 4 1 Table 4 2 Service Replaceable Parts 16089A Replaceable Parts 16089A Replaceable Parts Keysight Part Number Quantity Description 16089 60001 1 Test Leads 16089 04001 1 Cover Top 0515 0914 2 Screw Flat Head M3X0 5 L6 16089 60011 2 Large Clip As
5. 52 227 19 c 1 2 J une 1987 U S Government users will receive no greater than Limited Rights as defined in FAR 52 227 14 j une 1987 or DFAR 252 227 7015 b 2 November 1995 as applicable in any technical data Safety Notices CAUTION A CAUTION notice denotes a hazard It calls attention to an operating procedure practice or the like that if not correctly performed or adhered to could result in damage to the product or loss of important data Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met WARNING A WARNING notice denotes a hazard It calls attention to an operating procedure practice or the like that if not correctly performed or adhered to could result in personal injury or death Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met Safety Summary WARNING DO NOT Substitute Parts or Modify the Instrument The following general safety precautions must be observed during all phases of operation service and repair of this instrument Failure to comply with these precautions or with specific WARNINGS given elsewhere in this manual may impair the protection provided by the equipment Such noncompliance would also violate safety standards of design manufacture and intended use of the instrument Keysight Technologies assumes no liability for the customer s failure to comply with these precautions
6. the effects caused by these residuals and thus minimize their effect on measurement accuracy the measurement instrument s OPEN and SHORT compensation capabilities must be used The procedures are described in the measurement instrument s operation manual Figure 3 3 Making a Short Condition for the 16089B and 16089C Vv marks Red Black Voltage Voltage terminal terminal a a hann ry 4 Current Current terminal terminal Current terminal 160898 16089C When you perform SHORT compensation for the 16089A or 16089D use the furnished short bar as shown in Figure 3 4 Figure 3 4 Making a Short Condition for the 16089A and 16089D V markers IOSIA 1689D NOTE If the furnished short bar of 16089A or 16089D is corroded worn or damaged reverse the position or replace it with a new short bar To reverse the short bar remove the 2 screws that fixes the short bar and reverse the position 23 NOTE Figure 3 5 Operation OPEN and SHORT Compensation Operation Step by step instructions on how to make a measurement with the 16089A B C D are 1 Set the Cable Length setting according to the LCR meter Impedance Analyzer operation manuals 2 Connect the test leads of 16089A B C D to the measurement instrument s UNKNOWN terminals 3 Perform OPEN and SHORT compensation as described in the measurement instrument s operation manual Figure 3 3 and Figure 3 4 show how to make short condition for the SHORT compensation
7. 24 Introduction 25 Replaceable Parts 25 16089A Replaceable Parts 16089B Replaceable Parts 16089C Replaceable Parts 16089D Replaceable Parts 26 26 27 28 Service General Information Introduction 16089A B C D Operation and Service Manual 1 General Information Introduction The purpose of this manual is to enable you to use your Keysight 16089A B C Kelvin Clip Leads and Keysight 16089D Alligator Clip Leads efficiently and confidently This manual contains both general and specific information To use the 16089A B C D to perform a specific function without having to read the entire manual follow the directions in Using the 16089A B C D Using the 16089A B C D The 16089A B C D has been designed to operate specifically with the LCR Meter To install the 16089A B C D turn to Chapter 2 To operate the 16089A B C D turn to Chapter 3 To order replaceable parts for the 16089A B C D turn to Replaceable Parts in Chapter 4 KEYSIGHT TECHNOLOGIES General Information Product Description Product Description The 16089A B C D has been designed to operate specifically with the following four terminal pair type LCR meters and impedance analyzers The 16089A B C D make it possible to measure odd shaped components that cannot be measured with conventional test fixtures The 16089A 16089B and 16089C consist of a direct attachment four terminal pair type test leads that are equipped wi
8. IMPLIED WITH REGARD TO THIS MANUAL AND ANY INFORMATION CONTAINED HEREIN INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE KEYSIGHT SHALL NOT BE LIABLE FOR ERRORS OR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING USE OR PERFORMANCE OF THIS DOCUMENT OR ANY INFORMATION CONTAINED HEREIN SHOULD KEYSIGHT AND THE USER HAVE A SEPARATE WRITTEN AGREEMENT WITH WARRANTY TERMS COVERING THE MATERIAL IN THIS DOCUMENT THAT CONFLICT WITH THESE TERMS THE WARRANTY TERMS IN THE SEPARATE AGREEMENT WILL CONTROL Technology Licenses The hard ware and or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license Restricted Rights Legend If software is for use in the performance of a U S Government prime contract or subcontract Software is delivered and licensed as Commercial computer software as defined in DFAR 252 227 7014 J une 1995 or as a commercial item as defined in FAR 2 101 a or as Restricted computer software as defined in FAR 52 227 19 J une 1987 or any equivalent agency regulation or contract clause Use duplication or disclosure of Software is subject to Keysight Technologies standard commercial license terms and non DOD Departments and Agencies of the U S Government will receive no greater than Restricted Rights as defined in FAR
9. Keysight 16089A B C D Kelvin Alligator Clip Leads Operation and KEYSIGHT Service Manual TECHNOLOGIES Notices Keysight Technologies 1991 2015 No part of this manual may be reproduced in any form or by any means including electronic storage and retrieval or translation into a foreign language without prior agreement and written consent from Keysight Technologies as governed by United States and international copyright laws Manual Printing History The manual s printing date and part number indicate its current edition The printing date changes when a new edition is printed minor corrections and updates that are incorporated at reprint do not cause the date to change The manual part number changes when extensive technical changes are incorporated November 1991 Edition 1 J anuary 2000 Edition 2 April 2001 Edition 3 November 2002 Edition 4 J uly 2010 Edition 5 part number 16089 90020 May 2015 Edition 6 part number 16089 90030 Manual Part Number 16089 90030 Edition Edition 6 May 2015 Printed in Malaysia Published by Keysight Technologies International Japan G K 1 3 3 Higashikawasaki cho Chuo ku Kobe shi Hyogo Japan Warranty THE MATERIAL CONTAINED IN THIS DOCUMENT IS PROVIDED AS IS AND IS SUB ECT TO BEING CHANGED WITHOUT NOTICE IN FUTURE EDITIONS FURTHER TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW KEYSIGHT DISCLAIMS ALL WARRANTIES EITHER EXPRESS OR
10. an instrument will execute its programming instruction when property installed on that instrument Keysight Technologies does not warrant that the operation of the instrument or software or firmware will be uninterrupted or error free Limitation of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by the Buyer Buyer supplied software or interfacing unauthorized modification or misuse operation outside of the environmental specifications for the product or improper site preparation or maintenance No other warranty is expressed or implied Keysight Technologies specifically disclaims the implied warranties of merchantability and fitness for a particular purpose Exclusive Remedies Assistance The remedies provided herein are Buyer s sole and exclusive remedies Keysight Technologies shall not be liable for any direct indirect special incidental or consequential damages whether based on contract tort or any other legal theory Product maintenance agreements and other customer assistance agreements are available for Keysight Technologies products For any assistance contact your nearest Keysight Technologies Sales and Service Office Safety Symbols General definitions of safety symbols used on the instrument or in manuals Gtppe jl PB Instruction Manual symbol the product is marked with this symbol when it is necessary for the user to refer to the
11. anteed Supplemental Performance Characteristics of 16089A Applicable DUT size Diameter of DUT s terminals lt 15mm Supplemental Performance Characteristics of 16089B Applicable DUT size Diameter of DUT s terminals lt 7 9mm Length of DUT s terminals 23mm Supplemental Performance Characteristics of 16089C Applicable DUT size Diameter of DUT s terminals lt Imm Space between DUT s terminals gt 2mm Length of DUT s terminals 22mm Supplemental Performance Characteristics of 16089D Applicable DUT size Diameter of DUT s terminals lt 5mm General Information Supplemental Performance Characteristics Preparation for Use Introduction 16089A B C D Operation and Service Manual 2 Preparation for Use Introduction This chapter explains how to install the Keysight 16089A B C Kelvin Clip Leads and Keysight 16089D Alligator Clip Leads The topics covered include initial inspection ambient environmental considerations connecting the test leads for use and repackaging the test leads for shipment Initial Inspection These test leads have been carefully inspected electrically and mechanically before being shipped from the factory They should be in perfect physical condition no scratches dents or the like They should also be in perfect electrical condition Verify this by carefully performing an incoming inspect
12. ing testing and adjusting this instrument Certification Warranty Keysight Technologies certifies that this product met its published specifications at the time of shipment from the factory Keysight Technologies further certifies that its calibration measurements are traceable to the United States National Institute of Standards and Technology to the extent allowed by the Institution s calibration facility or to the calibration facilities of other nternational Standards Organization members This Keysight Technologies instrument product is warranted against defects in material and workmanship for a period of one year from the date of shipment except that in the case of certain components listed in Instrument Specifications of this manual the warranty shall be for the specified period During the warranty period Keysight Technologies will at its option either repair or replace products which prove to be defective For warranty service or repair this product must be returned to a service facility designated by Keysight Technologies The Buyer shall prepay shipping charges to Keysight Technologies and Keysight Technologies shall pay shipping charges to return the product to the Buyer However the Buyer shall pay all shipping charges duties and taxes for products returned to Keysight Technologies from another country Keysight Technologies warrants that its software and firmware designated by Keysight Technologies for use with
13. instrument manual in order to protect against damage to the instrument Alternating current Direct current On Supply Off Supply In position of push button switch Out position of push button switch A chassis terminal a connection to the instrument s chassis which includes all exposed metal structure Standby Contents NEDE NE E EEE PT ee m mm mm m mkymrm m mrmmamam r c c c cua General Information Introduction 9 Using the 16089A B C D 9 Product Description 10 Accessories Supplied 10 Operating and Safety Precautions 11 Operating 11 Service 11 Specifications 12 Common Specifications for the 16089A B C D 12 Specifications for the 16089A B C T2 Specifications for the 16089D 12 Supplemental Performance Characteristics 13 Supplemental Performance Characteristics of 16089A 13 Supplemental Performance Characteristics of 16089B 13 Supplemental Performance Characteristics of 16089C 13 Supplemental Performance Characteristics of 16089D 13 Sih Sb Rae EE bee tes ed bokeh ee whee rom Preparation for Use Introduction 15 Initial Inspection 15 Ambient Environmental Considerations 20 Operating and Storage 20 Connecting the Test Leads for Use 20 Packaging the Test Leads 20 ELS Tee ere ETT ToT eT ee ee ee Te cee Tee eye rT ye ee re Operation Introduction 21 Test Leads Features 21 16089A B C 21 16089D 22 OPEN and SHORT Compensation 23 Contents Operation
14. ion to check the test lead set for signs of physical damage and missing contents If any discrepancy is found notify the carrier and Keysight Technologies Your Keysight Technologies sales office will arrange for repair and replacement without waiting for the claim to be settled Inspect the shipping container for damage Keep the shipping materials until the inspection is completed Verify that the shipping container contains everything shown in Figure 2 1 Figure 2 2 Figure 2 3 and Figure 2 4 and listed in Table 2 1 Table 2 2 Table 2 3 and Table 2 4 Inspect the exterior of the 16089A B C D for any signs of damage KEYSIGHT TECHNOLOGIES Preparation for Use Initial Inspection 16089A Figure 2 1 16089A Product Overview Table 2 1 Contents of 16089A Description Keysight Part Number Quantity Kelvin Clip Leads 16089 60001 1 Operation and Service Manual 16089 90030 1 Keysight internal only part number 2 Operation and Service Manual is not shown in Figure 2 1 1 Preparation for Use Initial Inspection 16089B Figure 2 2 16089B Product Overview Table 2 2 Contents of 16089B Description Keysight Part Number Quantity Kelvin Clip Leads 16089 600021 1 Operation and Service Manual 16089 90030 1 1 Keysight internal only part number 2 Operation and Service Manual is not shown in Figure 2 2 Preparation for Use Initial Inspection 16089C Figure 2 3 16089C Product Overview
15. packaging materials may be used Wrap the test leads in heavy paper and pack in anti static plastic packing material Use sufficient shock absorbing material on all sides of the 16089A B C D to provide a thick firm cushion and to prevent movement Seal the shipping container securely and mark it FRAGILE 20 Operation Introduction 16089A B C D Operation and Service Manual 3 Operation Introduction This chapter describes using the test leads and compensation techniques for these test leads Test Leads Features 16089A B C Figure 3 1 16089A B C Test Leads Features 1 Kelvin Clips These are connected to the DUT 16085 A 1608918 10C 2 Four terminal pair BNC terminals These terminals are connected to the UNKNOWN terminals of your measurement instrument KEYSIGHT TECHNOLOGIES 21 Operation Test Leads Features 16089D Figure 3 2 16089D Test Leads Features Alligator Clips red These are connected to the high terminal of the DUT Alligator Clips black These are connected to the low terminal of the DUT V markers These show the Hoot and Lpot terminals UoN Four terminal pair BNC terminals These terminals are connected to the UNKNOWN terminals of your instrument 22 Operation OPEN and SHORT Compensation OPEN and SHORT Compensation The 16089A B C D have inherent stray capacitance residual inductance and residual resistance that affect the measurement To cancel
16. sembly 7121 2696 2 Wire Marker V 16089 01201 1 Short Bar 0515 1550 2 Screw 1 The whole unit Keysight internal only part Red and orange cables are screwed on the one Kelvin clip assembly Gray and black cables are screwed on the other Kelvin clip assembly Orange and gray cables are marked V 16089B Replaceable Parts 16089B Replaceable Parts Keysight Part Number Quantity Description 16089 60002 1 Test Leads 16089 04002 1 Cover Top 0515 0914 2 Screw Flat Head M3X0 5 L6 16005 60010 2 Kelvin Clip Assembly 1 The whole unit Keysight internal only part On one Kelvin clip the orange cable is screwed on the V marked side and the red cable is screwed on the non marked side On the other Kelvin clip the gray cable is screwed on the V marked side and the black cable is screwed on the non marked side 26 Service Replaceable Parts 16089C Replaceable Parts Table 4 3 16089C Replaceable Parts Reference Keysight Part Number Quantity Description Designator 16089 60003 1 Test Lead 16089 04003 1 Cover Top 0515 0914 2 Screw Flat Head M3X0 5 L6 1 16005 60013 1 Test Clip Assembly Red 16005 60015 1 Test Clip Assembly Black 2 0890 1809 2 cm Tube Heat Shrinkable Red 0890 1808 2 cm Tube Heat Shrinkable Black Corresponding to designator in Figure 4 1 1 The whole unit Keysight internal only part Connection from the cables to the Kelvin clip is shown in Figure 4 1
17. th two insulated Kelvin clips Three sizes of Kelvin clips are provided The 16089A Kelvin Clip Leads is equipped with two large Kelvin clips the 16089B Kelvin Clip Leads is equipped with middle size clips and the 16089C Kelvin Clip Leads is equipped with small size clips The 16089D consist of a direct attachment four terminal pair type test leads that are equipped with four alligator clips Accessories Supplied Table 1 1 The following accessories are supplied with the 16089A B C D Furnished Accessories Description Part Number Quantity Operation and Service Manual This manual 1 General Information Operating and Safety Precautions Operating and Safety Precautions Operating CAUTION Service You need to observe only normal precautions in handling and operating the 16089A B C D Do not exceed the operating input power voltage and current level and signal type appropriate for the instrument being used refer to your instrument s operation manual Electrostatic discharge ESD can damage the highly sensitive microcircuits in your instrument ESD damage is most likely to occur as the test leads are being connected or disconnected Protect them from ESD damage by wearing a grounding strap that provides ahigh resistance path to ground Alternatively ground yourself to discharge any static charge built up by touching the outer shell of any grounded instrument chassis before touching the test port connectors Never
18. touch the test clip contacts Use a work station equipped with an anti static work surface The voltage levels found in these test leads when used with the intended instruments do not warrant more than normal safety precautions for operator safety Nevertheless service should be performed only by qualified personnel General Information Specifications Specifications This section lists the complete 16089A B C D specifications These specifications are the performance standards and limits against which the 16089A B C D is tested When shipped from the factory the 16089A B C D meets the following specifications Common Specifications for the 16089A B C D Specifications for the 16089A B C Specifications for the 16089D Maximum dc Bias Voltage 42V peak max Frequency Range 5 Hz to 100 kHz Operating Temperature 0 to 55 C Operating Humidity lt 95 RH 40 C Non operating Temperature 40 to 70 C Non operating Humidity lt 95 RH 40 C Weight 300 g Cable length 0 94m Cable length 1 3m General Information Supplemental Performance Characteristics Supplemental Performance Characteristics This section gives supplemental performance characteristics Supplemental performance characteristics are not specifications but are typical characteristics included as additional information for the operator Supplemental performance characteristics are not guar