1. Turn power off at the breaker Turn dip switch No 7 to ON Reapply power The STRATUM includes a feature that determines whether the pump has continued to run after the system has tried to shut the pump off VR1000 VER X X The start delay allows the installer to be ready for the system to start is During initial start up and set up the start delay should not be disabled Initial Start OK A press of the OK button will start the system Answering YES will allow the system to restart during normal operation Initial Set up Answering No will cause the system to come up to the VR1000 VER XX Initial Start OK screen Complete Y N above and stop when there is a loss of power Skip Past Function Answer No Time delay for first air pulse This is equal to 1 2 Sol Mot Delay seconds which by test has been established as time needed to get the priming of a lift pump 120 Change Y N started Generally this value should not need to be changed SU Pulse Units This valve 1s the air charge used to help break a high vacuum due to surge The default value 50 Change Y N on 50 is equal to 5 seconds For FLOODED suction this value will be required to be Be adjusted up Generally a 150 value for FLOODED suction works well Set H2O Hammer Skip Past Function Answer No This is a time value after the 5 hour periodic test to Delay Y N avoid a high vacuum due to the test The default value is 8 is equal to 2 seconds
2. MR2 Motor Relay 2 Used for Low Speed on the Filter Pump MR3 Motor Relay 3 Used for Booster Cleaner Pump Over Window Vacuum Indicates a vacuum level detected that is above normal for the pool system The system should restart SP Spare switch contact used to run the STRATUM in High Speed when timer function is timed out or pump is in low speed Stabilizing The STRATUM has started the priming function and is in the process of finding a fully primed vacuum Startup Pulsing The Solenoid Valve is opened and closed several times to soft start the system at startup to warn swimmers Under Vacuum Window Indicates a problem with the inlet water flow to the pump Low volume flow can be caused by line breaks or low water levels The system should restart Unprotected Mode Is when the pump is operating and the STRATUM is NOT providing any protection against Body Suction Entrapment Swimmers and Bathers should not be allowed in the pool and spa when the STRATUM is in Unprotected mode Window A window 1s a set of limits which is placed around the operating Vacuum In the STRATUM this window is 3 Hg USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona CA Clemmons NC Nashville TN Tel 908 351 5400 www haywardpool com HAYWARD Poo Products a A Hayward Industries Inc Company
3. The STRATUM comes set for 3 or less lift this An ADC count of 60 The ADC count Weld Relay ADC is adjustable from to 140 The number is adjustable by using YES for Up and NO 60 CHANGE Y N for down Exit with OK Increasing numbers would generally be associated with higher vacuum pumps and high lifts Weld Rly ADC CNT This value will have to be adjusted for high lift situations The default value of 60 is used for 3 lift or less 80 for4 lift 100 for 5 lift 120 for 6 lift 140 for 7 lift Note The setting 1s not exact and additional lift at these setting should not cause the system to shut down This function should always be engaged on the STRATUM so the appropriate answer Enable Welded ig Y Relay Test Y N Answering Y will allow the system to restart during normal operation Initial Set up Answering No will cause the system to come up to the VR1000 VER XX Initial Start Complete Y N OK screen above and stop when there is a loss of power POWER The STRATUM Down Turn Dip Switch 7 OFF USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona CA Clemmons NC Nashville TN BE hava WA RD POOL PTOUCH Tel 908 351 5400 www haywardpool com Page 20 of 24 STRATUM Model VR1000 P N ISVRIOOOTECH Rev J RECORDED CODES ET 1 Low AC voltage detected 3 16 bit ADC values Actual value Low Limit and High Limit ET 2 High AC voltage detected 3 16 bit ADC values Actual v
4. Wiring relays for 240 VAC Aqua Logic Pool Equipment Ru HAYWARD roo Products eer A Hayward Industries Inc Company Solenoid Valve 115 VAC 230VAC SERVICE SWITCH CONTACTOR P N ISVRIOOOTECH Rev J SELECT VOLTAGE ON BOOSTER Ab S BOARD To MATCH AP L1 N L2 115 VAC OR 208 230 VAC 4 L2 FIG 5 Internal Control Ground DEFTIONAL BOOSTER FUMP 115 VAC OR 208 230 VAC External FIE of ta ae E Aqua Logic Wiring relays for 120 VAC Pool Equipment 115 VAC 208 230 VAC Power In TO RELAY TERMIHAL amp VACUUM TO RELAY TERMINAL 2 RELEASE FROM RELAY SYSTEM TERMINAL FIG 8 THREE PHASE PUMP MOTOR SUGGESTED CONNECTION Pomona CA Clemmons NC Nashville TN Tel 908 351 5400 www haywardpool com Page 8 of 24 STRATUM Model VR1000 P N ISVRIOOOTECH Rev J Note For Flooded Suction and Pumps installed more than 3 above the surface of the pool Turn on Dip Switch 7 before Appling power to the STRATUM See Page 19 INITIAL SCREENS These will disappear after the Initial Set up 1s complete VRI 000 VER X X The start delay allows the installer to be ready for the system to start Initial Start OK During initial start up and set up the start delay should not be disabled A press of the OK button will start the system Initial Set up Answering YES will allow the system to restart during normal operation Complete Y N Answering
5. Model VR1000 P N ISVRIOOOTECH Rev J SPECIAL CONSIDERATIONS When installing the VR1000 system on a two speed pump that requires suction lift Self priming the VR100 must be installed within 10 feet of the pump This requirement is primarily due to the low vacuums generated by the low speed On flooded suction applications an extension of the vent tube above the water line will provide the venting required On flooded suction with a two speed pump not only is a relatively short vacuum tube Under 8 required but the VR1000 Zero Vacuum sensor may need to be reset if the VR 1000 does not stabilize in low speed This 1s a special condition in that the head pressure from the flooded suction should be considered in the Zero of the Vacuum sensor DO NOT disconnect the vacuum tube Reset the 1 Stab Occurred after this Zero event The current system has been tested in flooded suction conditions up to 4 below the surface of the pool In Flooded suction the maximum measured vacuum must be below 20 Hg when operating This may require throttling a down stream valve The VR1000 is designed to be used on a single pump or a combination of a single pump with a booster pump on a common suction line ASSEMBLY INSTRUCTIONS SPARE PARTS DISCONNECT POWER FROM THE SOURCE l m HAYWARD Pool Products Pomona CA Clemmons NC Nashville TN a A Hayward Industries Inc Company Tel 908 35 5400 www haywardpool com The solenoid valve VRX1
6. OFF times for every day even if you want them all to be the same All times are adjusted in 1 minute increments If you program the ON time equal to the OFF time 12 01A to 11 59P the output will always be ON For the Booster pump timer ON time equals OFF time the pump will always be OFF 7 DAY MODE YES will use the timing events currently stored in the VR1000 NO will allow setting the timers Blinking time indicates that the timer is ready to be set Down will move On time earlier UP will move On time later Menu OK to go to next screen Blinking time indicates that the timer is ready to be set Down will move On time earlier UP will move On time later Menu OK to go to next screen Blinking time indicates that the timer is ready to be set Down will move On time earlier UP will move On time later Menu OK to go to next screen Blinking time indicates that the timer is ready to be set Down will move On time earlier UP will move On time later Menu OK to go to next screen Low Speed On will only appear if dip switch 3 is ON This will allow setting the timing on the Low speed of a two speed pump A No will allow setting the On and Off time Follow the above instructions for the timer settings BST On is the timer for the Booster Pump To set timer follow the above Repeat the above for the second timer cycle For OVERNIGHT operation set the fi
7. configuration that showed the lowest vacuum level for column B This configuration should be used for the initiation of the VR1000 Is Anyone in Pool or Spa Y N Pressing No will allow the system to go into Unprotected Mode for 30 minutes Pressing YES will not allow activation mode and return you to the TECH Mode Screen Unprotected Mode To stop Unprotected mode before the 30 minute period has expired press OK Press OK to End These two screens alternate and are for information purposes only Unprotected Pool Vacuum X X Exiting Unprotected Mode USE ONLY HAYWARD GENUINE REPLACEMENT PARTS m HAYWARD Pool Products Pomona CA Clemmons NC Nashville TN ui A Hayward Industries Inc Company Tel 908 35 5400 www haywardpool com Page 9 of 24 STRATUM Model VR1000 P N ISVRIOOOTECH Rev J This displays the current time and date The system was initiated in the Eastern Time Zone 02 02 06 12 00 P M SET TIMER EVENTS Y N SET TIME AND DATE Y N SELECT POOL TECH MODE Y N It is required that the time of day clock be changed on first start up Even if this change is forward a minute and then back If the date and time are not maintained from the last time it was set the battery may need to be replaced YES follow screen instructions SET TIMER EVENTS is the only used when the VR1000 has been set to allow control of pump on off times or with use of a 2
8. haywardpool com Page 13 of 24 STRATUM Model VR1000 P N ISVRIOOOTECH Rev J Start Up amp Operation Prior to Start Up Notice If it is necessary to perform a pressure test prior to initial use to ensure pump is functioning properly The following criteria should be maintained for this test 1 Ensure all pump and system components are sealed properly to prevent leaks 2 Remove any trapped air in the system by fully opening filter manual air relief valve until a steady stream of water is discharged 3 Allow no more than 40 psi 172 kPa at a water temperature no higher than 100 F 38 C 4 Run pressure test for no longer than 24 hours Immediately inspect all parts to verify they are intact and functioning properly 5 Have a professional perform this test Fill strainer housing with water to suction pipe level NEVER OPERATE THE PUMP WITHOUT WATER Water acts as a coolant and lubricant for the mechanical shaft seal A ATTENTION NEVER run pump dry Running pump dry may damage seals causing leakage flooding and voids warranty Fill strainer housing with water before starting motor A ATTENTION Do NOT add chemicals to pool spa system directly in front of pump suction Adding undiluted chemicals may damage pump and voids warranty A ATTENTION Before removing strainer cover 1 STOP PUMP before proceeding 2 CLOSE VALVES in suction and outlet pipes 3 RELEASE ALL PRESSURE from pump and piping system
9. it is strongly recommended to protect the electrical components from the weather Select a well drained area one that will not flood when it rains It requires free circulation of air for cooling Do not install in a damp or non ventilated location If installed within an outer enclosure or beneath the skirt of a hot tub or spa adequate ventilation and free circulation of air must be provided to prevent overheating of the components WARNING All electrical wiring MUST be in conformance with all applicable local codes regulations and the National Electrical Code NEC Risk of Electric Shock Hazardous voltage can shock burn cause death or serious property damage To reduce the risk of electric shock do NOT use an extension cord to connect unit to electric supply Provide a properly located outlet All electrical wiring MUST be in conformance with applicable local and national codes and regulations Before working on pump or motor turn off power supply to the pump A WARNING To reduce the risk of electric shock replace damaged wiring immediately Locate conduit to prevent abuse from lawn mowers hedge trimmers and other equipment WARNING All electrical wiring MUST be in conformance with all applicable local codes regulations and the National Electrical Code NEC including a Ground Fault Circuit Interrupter GFCI in circuit For size of GFCI required and test procedures for GFCI see manufacturer s instructions Pump MUST be permane
10. lines Menu key pushed in error detected delays 1 parm will indicate where in this code the key was detected It will be 1 2 or 3 3 fatal errors in a row no operator response in 10 minute window an operator menu key double click occurred sometime later to restart system USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona CA Clemmons NC Nashville TN Tel 908 351 5400 www haywardpool com Page 23 of 24 STRATUM Model VR1000 P N ISVRIOOOTECH Rev J The STRATUM has several built in functions that should be considered 1 There is a function that determines if the pump is running when it is not suppose to be running When this feature 1s engaged it will open the solenoid valve venting the system and set off the buzzer Generally this function is a safety backup function POWER the PUMP and STRATUM off at the circuit breaker and replace the Contactor 2 Ifthe STRATUM fails to restart after a filter has been cleaned or equipment replaced the first stabilized Vacuum should be reset in Custom Install Procedures See Page 14 3 When the STRATUM is installed on a SPA where the Normal operation is in Low speed on a two speed pump it is suggested that the STRATUM be set up such that it starts in High Speed to prime and then always drops down to Low Speed When the Spa is to be used Or High Speed Pump operation closing the contact between the Spare and common terminals on the STRATUM board will bring the pump
11. non blocked recorded suction value to be used as the High Vac Value Page 14 If possible check to assure the fully blocked suction is above the High Vac Value Correct Installation of Saddle Fitting No valves between the pump and the saddle fitting Do Not Install the Saddle fitting in the positions marked with an X There would be a valve between the pump and the saddle fitting PUMP SADDLE FITTING VALVE USE ONLY HAYWARD GENUINE REPLACEMENT PARTS HAYWARD Pool Products Pomona CA Clemmons NC Nashville TN A Hayward Industries Inc Company Tel 908 351 5400 www haywardpool com Page 18 of 24 STRATUM Model VR1000 P N ISVRIOOOTECH Rev J PINCHED TUBE SET UP and TEST Turn power off at the breaker Turn dip switch No 8 to ON Reapply power VR1000 VER X X Initial Start OK Initial Set up Complete Y N O E a co c Y N J RV e e ga Pinch Maybe 2 Change Y N S Up Pinch Dif 2 Change Y N Pinch Fail Dif 20 Change Pinch Vacuum Tube Test ON The start delay allows the installer to be ready for the system to start During initial start up and set up the start delay should not be disabled A press of the OK button will start the system Answering YES will allow the system to restart during normal operation Answering No will cause the system to come up to the VR1000 VER XX Initial Start OK screen above and stop when t
12. operation instructions could result in violent separation of pump components Strainer cover must be properly secured to pump housing with strainer cover lock ring Before servicing pool and spa circulation system manual air relief valve must be in open position Do not operate pool and spa circulation system if a system component is not assembled properly damaged or missing Do not operate pool and spa circulation system unless filter air relief valve body is in locked position in filter upper body A WARNING Never operate or test the circulation system at more than 40 PSI A WARNING Fire and burn hazard Motors operate at high temperatures and if they are not properly isolated from any flammable structures or foreign debris they can cause fires which may cause severe personal injury or death It is also necessary to allow the motor to cool for at least 20 minutes prior to maintenance to minimize the risk of burns WARNING Failure to install according to defined instructions may result in severe personal injury or death DEFINITIONS Suction Outlet The term Suction Outlet is a fitting fitting assembly cover grate and related components that provide a means for water to exit the pool and into the pump circulating system Inches of Mercury in Hg A unit for measuring pressure below atmospheric suction or vacuum 1 0 inch Hg 491 PSI Main Drain See Suction Outlet PSI An abbreviation for pounds per square
13. speed pump See Page 10 for screen information For the Start up Set up of the VR1000 it is recommended that the Custom Install Procedures be run before the system is allowed to find its initial Prime Vacuum Value Rapidly Push the Menu button twice See Custom Install Procedures on page 14 SCREENS showing errors and exceptions VRIOOO VER X X SIOP SWITCH VR1000 VER X X S S VENT ERROR VR1000 VER X X NO STABILIZATION VR1000 VER X X SELF TEST VR1000 OVER WINDOW VACUUM VR1000 UNDER WINDOW VACUUM HIGH VACUUM SYSTEM WON T STABILIZE TOO MANY SEN SOL ERRS OR NO PRIME 7 HAYWARD bo Products mee A Hayward Industries Inc Company The system will not start if the optional STOP Switch is pressed in Action Required Reset STOP Switch Sensor Solenoid Venting Error Remove and clean or replace the vent plug This is the cone shaped device on the exterior bottom of the box See Fig 1 If vent cleaning replacement does not correct the problem replace the solenoid valve See Fig 9 No Stabilization indicates that there is likely a problem with the pump The pump basket should be checked for debris Other pumping issues can cause stabilization problems Self Test Indicates the system is checking itself for proper operation of its components No Customer Action is required Over Window Vacuum indicates a vacuum level detected that is above normal for the pool syste
14. terminals are disconnected Thus if a Manual override is desired a maintained contact switch can be used to between these terminals For Flooded Suction and Pumps located more than 3 above the pool turn on Dip Switch 7 See Page 19 Replace the inner barrier and secure with two screws included Power should be applied to the system while watching the display Follow the directions on the display This operation will confirm the available voltage is suitable for proper operation of the VR system NOTICE THE CIRCUIT BOARD AND COMPONENTS MAY BE DAMAGED IF 208 230V AC IS APPLIED TO THE BOARD WHEN THE SWITCH IS IN THE 115VAC POSITION 13 14 Close the electrical enclosure Apply power to system USE ONLY HAYWARD GENUINE REPLACEMENT PARTS PJH AYW ARD Poo Finite Pomona CA Clemmons NC Nashville TN EX A Hayward Industries Inc Company Tel 908 351 5400 www haywardpool com Page 7 of 24 STRATUM Model VR1000 Display OFF NO MENU DOWN OK 4Nnd H315008g 0324 MOT 3 033d amp HSH amp una wala eo aoo VOLTAGE RELAY SELECTOR RATED 115 VAC amp AMP E AW144 HOLOW AV13H HO LON k AV 13H HOLON HILIMS doOLS amp IVHINH3L HOILVIINNAAOD n oe Zo 5E lt m Ta Zr zo Zu m am FIG 4 Solenoid Valve BOOSTER Filter 415 VAC OR Ground nee qu pO FIG 6 BOOSTER FUMF Internal Control 3 Phase Line Voltage MOTOR STARTER RELAY 3 PHASE PUMP
15. to high Speed Protected mode for as long as the contact is maintained Note This 1s a non powered contact which is looking for a closed contact to energize the High Speed on the Pump 4 Hayward recommends that the time of day clock be changed on first start up Even if this change is forward a minute and then back This operation will confirm that the time clock is running and recording correctly 5 Ifthe Vacuum Release System has shut the pump down due to HIGH VACUUM and does not restart due to debris in the suction line the line must be cleared This 1s normally done through the use of a garden hose or other method 6 Ifthe green light 1s on and the Red light is on with the Pump not running during a normal operational time cycle it is suggested that cutting the power to the system and then restoring the power will reset the system This will assure the system program is operating VY DETACH HERE Fill out bottom portion completely and mail within 10 days of purchase installation j Mailto Hayward Pool Products 620 Division Street Elizabeth NJ 07207 Attn Warranty Dept HAYWARD Pool Owner s Name Pool Owner s Address City State Zip O Commercial O Residential Product Purchased STRATUM VRI 000 Product ID No 21 120 Date Unit Installed In Ground Pool O Above Ground O Product Registration Card Purchased from Installer name Certified Address City State Zip E mail address Hi
16. 00E See Fig 9 is replaced by disconnecting the two wires marked Solenoid from the board Disconnect the tubes from the solenoid valve by pushing the fitting ring in toward the valve while gently pulling on the tubing Removing the two screws at the base of the valve will allow the solenoid valve to be removed from the box To reinstall the solenoid valve the fittings must be removed and replaced in the correct order Replace TFE tape as needed Per the labeling on the solenoid valve the 5 16 tube fitting is installed in Port A The 1 4 tube fitting is installed in Port P The metric Gray ring fitting is installed in Port R The short black 5 16 tubing is installed between the bulkhead and the solenoid valve The small black tubing is a metric tubing and 1s installed between the board and Port R on the solenoid valve The clear tubing is installed between the Vent fitting bulkhead and Port P of the solenoid valve Install the two screws that were removed to hold the solenoid valve in place Replace the wires in Solenoid position on the board Replacement Pump Contactors GLX RELAY See Fig 9 and wiring diagrams Two screws retain this contactor in place Aux contactors are installed beside and in line with the Filter Pump Contactor Booster Pump contactor must be connected to MR3 The wires should run from the contactor to the board Power is connected per the diagrams on Page 7 Apply the correct selected label to
17. Ferrule Nut 3 8 HOLE Fitting WA Vi M am A f Gasket 5 16 Tubing i Ferrule Mut FIG 2 LIST OF NEEDED ITEMS FOR INSTALLATION 1 VR1000 system 2 Location on vertical surface to install the VR1000 within ten feet of the pump and above the pump 3 25 length of tubing Supplied in package 4 For Pipe installation a 3 8 electric drill b 3 8 drill bit c Saddle Gasket CL220C Supplied in package d Saddle Fitting CL220G Supplied in package e Saddle Clamp CL220K Supplied in package f Ferrule Nut and Ferrule Supplied in package 5 Adjustable wrench 6 2 Phillips screw driver 7 Small bladed screw driver 8 Large bladed screw driver Mounting hardware for VR1000 Electrical box Not Supplied MECHANICAL MOUNTING INSTRUCTIONS FOR INGROUND POOLS WITHOUT FLOODED SUCTION Note If the installation is for an above ground pool or for flooded suction the VRX100F assembly is suggested The VR1000 is designed to be used on a single pump or a combination of a single pump with a booster pump on a common suction line l TURN OFF THE ELECTRICAL POWER AT THE CIRCUIT BREAKER 2 Remove all check valves from the suction lines of the Pool Spa system WARNING Check Valves must be removed from the circulation systems The presence of a check valve used to carry the water flow within the circulation system has been shown to prolong the high vacuum present at the drain even though the drain is protected by
18. No will cause the system to come up to the VR1000 VER XX Initial Start OK screen p above and stop when there 1s a loss of power SCREENS ON VR1000 For the set up of the VR1000 we recommend that the system be placed in the Unprotected mode which does not protected swimmers or bathers from entrapment It does allow the system to read the vacuum in various plumbing configurations Press NO and Menu simultaneously and hold in until the screen changes to place system in HAYWARD POOL Unprotected mode PRODUCTS Unprotected Answer Yes Mode Entry Y N A WARNING Body Suction Entrapment Hazard Suction in suction outlets can cause severe injury and or death due to a differential pressure applied to a large portion of the body or limbs STRATUM Unprotected Mode Is when the pump is operating and the STRATUM is NOT providing any protection against Body Suction Entrapment Do Not allow Swimmers and Bathers in the pool and spa when the STRATUM is in Unprotected mode The STRATUM only provides a layer of protection against Body Suction Entrapment in monitoring mode al NOTICE The STRATUM will beep to indicate the unit is in unprotected mode Various configurations of the plumbing system for the Pool and Spa should be should be set up with No Swimmers Allow the resulting vacuum level recorded See Run and Record Work Sheet page 17 In pool Spa Set up the Pool or Spa in the plumbing
19. PN ISVRIOOO0TECH Rev J HAYWARD Poo Products One source Every pool STRATUM L _ wrwe VRS MODEL VR1000 Il SERVICE MANUAL C US INSTALLATION amp PARTS LISTE HGH YOUNG A WARNING Kr ete CooL IURI OR DEATH May A WARNING Improper installation use or maintenance of this Vacuum Release System or associated equipment could cause serious or fatal injury To reduce the risk of injury read and follow all instructions in this Manual and on the equipment Make sure installation and any maintenance necessary are done by people who are qualified and have the proper equipment to do the job right All electrical wiring MUST be in conformance with all applicable local codes regulations and the National Electrical Code NEC Basic safety precautions should always be followed including the following Failure to follow instructions can cause severe injury and or death A his is the safety alert symbol When you see this symbol on your equipment or in this manual look for one of the following signal words and be alert to the potential for personal injury A WARNING warns about hazards that could cause serious personal injury death or major property damage and if ignored presents a potential hazard A CAUTION warns about hazards that will or can cause minor or moderate personal injury and or property damage and if ignored presents a potential hazard It can also make consumers aware of act
20. T tripping indicates electrical problem If GFCI trips and won t reset consult electrician to inspect and repair electrical system WARNING Fire Hazard Match supply voltage to motor nameplate voltage Insure that the electrical supply available agrees with the motor s voltage phase and cycle and that the wire size 1s adequate for the H P KW rating and distance from the power source NOTE All electrical wiring MUST be in conformance with all applicable local codes regulations and the National Electrical Code NEC Brake Horsepower Full Rate Horsepower Voltage 208 230 5 3 4 9 14 AWG 208 230 6 0 5 5 14 AWG 208 230 8 5 7 8 14 AWG 208 230 11 10 2 14 AWG Voltage at motor MUST NOT be more than 10 above or below motor name plate rated voltage or motor may overheat causing overload tripping and reduced component life If voltage is less than 90 or more than 110 of rated voltage when motor is running at full load consult power company Grounding Bonding Install ground bond and wire motor in accordance with local and national electrical code requirements Permanently ground motor Use green ground terminal provided under motor canopy or access place use size and type wire required by code Connect motor ground terminal to electrical service ground Reference NEC codes for all wiring standards including but not limited to grounding bonding and general wiring procedures Use a solid copper conductor size 8 o
21. a SVRS For this reason check valves which carry the water flow within the circulation system must be removed 3 Forinstallation of the vacuum sensing tube into the suction line of the pump See Page 17 for additional pictures a Locate a straight section of pipe approximately one foot long as close to the inlet of the pump as practical b Onthis straight pipe about in the middle go 45 from the top This will minimize the air entrapment in the system and help keep the system stable Drill a 3 8 hole See FIG 2 c Install the Saddle Gasket on the end of the Saddle fitting Place the assembly in the drilled hole Place the saddle clamp over the saddle fitting Tighten the Saddle clamp to assure a leak free joint DO NOT OVERTIGHTEN 4 Findalocation for the VR1000 on a wall or post out of the direct sunlight which will not be flooded and above the pump If the box is mounted below the water level the vent should be extended to above the water level 5 Place the Ferrule Nut over the tubing See FIG 2 Make sure the tubing bottoms out in the saddle fitting Holding the tubing in place tighten the Ferrule Nut firmly by hand DO NOT OVERTIGHTEN Run the 5 16 vacuum tube from the fitting on the suction line to the fitting on the VR1000 unit Make sure the vacuum tubing has no kinks and is strain free The fitting on the STRATUM does not require tooling to install the tubing Just insert the end of the tubing firmly into the fitting a sli
22. alue Low Limit and High Limit ET 43 Low AC voltage detected 3 16 bit ADC values Actual value Low Limit and High Limit ET 4 High AC voltage detected 3 16 bit ADC values Actual value Low Limit and High Limit ET 5 Power on 6 parms Zero value 2 bytes Hi spike value 2 bytes Difference value 1 byte in ADC units The following 3 will be 0 when DIP sw is ON DIP 3 2 speed pump en dis 1 byte DIP 4 timer en dis 1 byte DIP 6 Booster pump en dis 1 byte ET 6 OnHour OnMin OffHour amp OffMin byte values in El EA vars This entry won t be found if thetimer is DISABLED with the DIP switch 2 This entry indicates system was started because the current time moved inside the timer window ET 7 OnHour OnMin OffHour amp OffMin byte values in E1 E4 vars This entry won t be found if thetimer is DISABLED with the DIP switch 2 This entry indicates system was stopped because the current time moved outside the timer window ET 8 The time and date have been changed to the time and date of this entry ET 9 Low speed pump turned ON by timer 2 8 bit Parms On hour followed by On minute ET 10 Pulsing Stop switch ET 11 Pulsing Hi Spike 2 parms in 16 bit ADC units Hi Spike Threshold And actual trigger value ET 12 Pulsing Sensor Solenoid failure didn t see at least 1 2 1n Hg difference during pulsing 3 parms in ADC units highest amp values and 1 2 in Hg ET 13 Pulsing No Pump Prime failure wouldn t draw a p
23. aned or an equipment change since initial installation If the Initial Set Up with all the configurations of the plumbing has been complete and the High Vacuum for the system as well as the minimum vacuum has been determined then the installer should answer Y Yes to this question Answering No will cause the system to come up to the VR1000 VER XX Initial Start OK screen and stop when there is a loss of power The Pinched tube sensing system must be set up and tested after the three simulated entrapments have been conducted The simulated entrapments verifies proper installation of the STRATUM system Please see page 18 for detailed information USE ONLY HAYWARD GENUINE REPLACEMENT PARTS mm HAYWARD Goo Products Pomona CA Clemmons NC Nashville TN ui A Hayward Industries Inc Company Tel 908 35 5400 www haywardpool com Page 15 of 24 STRATUM Model VR1000 P N ISVRIOOOTECH Rev J This mode is used primarily for monitoring the system on start up and for providing data to the Select Pool pool tech to allow the VR1000 run trouble free Tech Mode Y N Pressing a Yes will allow additional screens not seen in User mode This question 1s for the Pool Tech to double check that the dip switch settings are for 2 speed motors if required Two Speed Motor Y N DRAIN COVER S Pressing the Y ES button will avoid a 10 minute delay INSTALLED Y N Note if NO is pressed th
24. cover the low voltage side of the contactor Fitting Kit VRX100KIT2 See Fig 2 Includes all parts except the tubing shown It also includes an extension clamp for larger size piping up to 3 The Fuse VRX100H See Fig 9 1s replaced on the board only if an abnormal power condition has occurred Tubing Replacement Kit VRX100PAK See Fig 9 This kit contains three pieces of tube to replace the tubing internally in the box The board end of the metric black tube is held on by a Barb connection Generally this end of the tube must be carefully slit to remove the tube Replacement order is covered in Solenoid Valve replacement Vent Filter VRX100F See Fig 9 In the event that the system gets repeated S S failures this fitting should be inspected to determine it has not been painted or otherwise contaminated Unscrew the fitting counterclockwise Replace be screwing on the new filter clockwise This kit includes fittings to extend the vent tube above the water level 25 of tubing CLX220J25 See Fig 2 Replacement tubing in case the initial tubing has been damaged Circuit Board VRXPCBA See Fig 9 Mark wires with respect to current location on circuit board Remove tube at connection to solenoid valve by pushing in the ring around the outside of the tubing and gently pulling the tubing out of the fiting Remove the wires from the green connector strip on the board Save the jumper from the stop switch connections Loosen the screws t
25. cracked missing or not securely attached A WARNING All suction and discharge valves MUST be OPEN when starting the circulation system Failure to do so could result in severe personal injury and or property damage All drains and suction outlets MUST have properly installed covers securely attached using the screws supplied with the covers If screws are lost order replacement parts from your supplier A WARNING Hazardous Pressure Pool and spa water circulation systems operate under hazardous pressure during start up normal operation and after pump shut off Stand clear of circulation system equipment during pump start up Failure to follow safety and operation instructions could result in violent separation of the pump housing and cover due to pressure in the system which could cause property damage severe personal injury or death Before servicing pool and spa water circulation system all system and pump controls must be in off position and filter manual air relief valve must be in open position Before starting system pump all system valves must be set in a position to allow system water to return back to the pool Do not change filter control valve position while system pump is running Before starting system pump fully open filter manual air relief valve Do not close filter manual air relief valve until a steady stream of water not air or air and water is discharged WARNING Separation Hazard Failure to follow safety and
26. dication Case 1 parm set to 99 the expected high vacuume value was less than the low vac value This is a pinched hose indication Case 2 parm set to difference between expected high value and low vacuum value Error occurs when this is lt to the PinchSupVal var which is set in Custom Inst Run Vacuum too low below 2 in of Hg 0 Pinch testing disabled not 0 enabled Run test button pushed Stuck welded motor relay detected 1st parameter is 8 bits 0 detected in power on start up code 1 detected in code just before startup pulsing 2 detected in timer code 3 detected in vacuum anomoly shutdown code In all of the above cases the pump motor appeared to be running when it shouldn t be running 2d parm is 16 bits actual vacuum in ADC units 3d parm 1s 16 bits Zero value Calib var plus Welded Relay ADC value which is set in DIP Sw 8 code sequence Note that motor is considered to be running if 2d parm is greater than 3d parm Hard shut down 3 consecutive SS errors or can t pull a prime after nn minutes errors 3 Hi Spikes in a row during pulsing stabilization 15 tries and no stabilization Custom installation procedure run Hi spike and difference values in ADC units are logged Start cleaning debris from intake lines Note that this entry into log will only be made and the service mode started 1f the operator responds NO to the Is Anyone in the Pool or Spa question End cleaning debris from intake
27. e system must be powered down before it will restart The RED LED light on the board will be displayed only if the system CPU has become disabled The pumps will not be running if this happens Power MUST be removed from the system The system should reboot when power is restored e Pushing and holding NO and OK keys at the beginning of pulsing will put system in Unprotected mode There is no safety checking of any kind while this is occurring This is a 30 minute cycle which can be repeated as required The measured vacuum will be displayed during the Unprotected mode e User has the following options when the startup questions are presented respond with yes or no keys and no response which will cause a 5 second timeout in each case and go to the next one e Sensor solenoid failure at end of pulsing if difference of at least 1 2 inch of Hg between highest and lowest vacuum is not detected e Pushing Menu OK key in pulsing or stabilization will go to the beginning of the power on and allow user to set date and time timer events if timer is enabled and enter pool technician mode etc The following Error Messages will cause shut down Stop Switch Activated on Power Up Low AC Voltage Detected VOLTAGE below 188VAC 100VAC High AC Voltage Detected STOP Switch has been Pushed High Vacuum Detected Sensor Failure System did not Stabilize Air Leak in System Over Window Vacuum Limit Detected Under Vacuum Limi
28. e the maximum allowable vacuum The maximum should NEVER be set higher than 5 Hg above the needed vacuum to run the pool cleaner This HIGH VACUUM is used during startup to determine that the Suction outlets are not blocked To proceed to the next screen press MENU OK This information screen shows the vacuum setting on exiting the Change High Vac Value This screen is to determine if the system is to set up for a Flooded Suction pump This screen will only display when the previous question is answered No for a lift pump The tubing on the bottom of the VR1000 should be disconnected by pushing on the fitting ring around the tubing and gently pulling the tubing from the fitting Press the Menu OK button when the tube is disconnected During the Sensor calibration phase this screen will be displayed This screen will only display for pool spa applications with a Lift pump Press the Menu OK button after the tube is reconnected This is a screen display issue as well as allowing correct voltage monitoring available to the system If the system is operating at 115 VAC select Yes If the system is operating at 208 230 VAC select No The system records the first stable vacuum value This value is used in several cases to determine if the pump is running properly This value should only be reset if there was an air leak on initial startup or after a significant suction change dirty filter cle
29. erate The STRATUM is shipped with this function OFF to allow for the Installation and set up of the system Inspect the vacuum tube for cracks or damage after the Pinch Tube set up 1s complete Turn Dip Switch 8 OFF after setting and testing the Pinched tube If the Pinch Tube test is operating correctly the STRATUM will pulse the solenoid introducing a small amount of air into the system to clear the vacuum tube The STRATUM will shut off the pump and sound the buzzer if the vacuum tube is held closed after the pulse Display Recent Log Entries Y N 10 05 07 FRI 10 14 40 ET 5 ARD Poo Products 00 isc sana akin cap eae Tel 908 351 5400 www haywardpool com The STRATUM has a running record of its interaction with the system This record or log can be displayed from the most recent to the oldest event in sequence The codes for these events are explained in the following pages A Y when this screen is displayed will allow viewing of the history of the system This particular event is a power on event A YES press of the button will go on to display the second half of the event record screen And more past records in sequence A NO press of the button will exit USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona CA Clemmons NC Nashville TN Page 19 of 24 STRATUM Model VR1000 P N ISVRIOOOTECH Rev J FOR FLOODED SUCTION AND PUMPS INSTALLED MORE THAN 3 ABOVE THE SURFACE OF THE POOL
30. et for flooded suction Dip Switch 8 performs special functions related to the detection of a pinched vacuum tube After the pinched tube settings have been made this switch should be turned to the OFF position to disable the screens but not the function ELECTRICAL CONNECTION INSTRUCTIONS l 2 3 10 11 p ASSURE POWER IS DISCONNECTED FROM SOURCE To install optional contactors the factory installed wires attached must be connected to the proper terminals on the circuit board For a booster pump always use motor relay 3 on the board as shown in FIG 4 Connect pump to contactor terminals 4 amp 8 See FIG 7 If a booster pump is used with a pool cleaner connect this pump to 4 amp 8 on a second contactor Optional Contactor VRX100KIT The contactor control 2 wires supplied MUST be connected onto the board next to the solenoid valve terminals that is in motor relay position 3 One reason to connect the booster pump through this system 1s to protect the booster pump motor from burn out if the VR1000 were to stop the primary filter pump Additionally the timers can then be used to control the timing of the Booster pump If a two speed pump is used connect the Low Speed to terminals 4 amp 8 on a contactor Optional Contactor VRX100KIT The contactor control 2 wires supplied MUST be connected onto the board in motor relay position 2 NOTE If the pump horsepower is greater than 3 HP the contactors can be used in series
31. gh Vacuum Setting Check all that apply LJ 2 Speed Pump O Single Main Drain Pool Dual Main Drains Pool O Single Main Drain Spa O Dual Main Drains Spa Booster Pump Skimmers Register On Line at WWW HAYWARDNET COM WARRANTY HAYWARD Poo Products MEE Hayward Industries Inc Company USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona CA Clemmons NC Nashville TN Tel 908 351 5400 www haywardpool com Page 24 of 24 External Contact Relay dAd H31 0089 0334 A S 03348 nom O anna uad 9 8 8 sIG amp 3 E 3 3 3 w amp 8 E AVIS HOLOM VOLTAGE SELECTOR E AW1aH HOJLON bk AW13H HOLOW H HOLIJVLINOS 036013 3AVH LEMA H31IME d4O0JS 3H dS5 annoys E TVNIIH3I MOLLYSIMITTIIN O3 6 Illustration for pump over ride to High Speed utilizing an AUX contact Glossary Calibrating A process during which the STRATUM detects the atmospheric pressure at a specific location G Internal Board common Ground contact used to run the STRATUM in High Speed when timer function is timed out or pump is in low speed High Vacuum Alert Indicates the system has stopped the pump vented and set off the alarm Monitoring The STRATUM has found a Stable fully primed vacuum and is providing a layer of protection from body entrapment STRATUM Model VR1000 P N ISVRIOOOTECH Rev J Glossary Continued MR1 Motor relay 1 Used for High Speed on the Filter Pump
32. ght pull should not dislodge the tubing USE ONLY HAYWARD GENUINE REPLACEMENT PARTS an HAYWARD Pool Products Pomona CA Clemmons NC Nashville TN BEI A Hayward Industries Inc Company Tel 908 351 5400 www haywardpool com Page 6 of 24 STRATUM Model VR1000 P N ISVRIOOOTECH Rev J m REQUIRED SETTINGS LU Diod The VR1000 unit is factory set for 230V AC input Leave the switch in this FACTORY SET position unless a low voltage error occurs in which case turn the power off and move the switch to 115VAC NOTICE THE CIRCUIT BOARD AND COMPONENTS MAY BE DAMAGED IF 208 230 VAC IS APPLIED TO THE BOARD WHEN THE SWITCH IS IN THE 115VAC POSITION The VR1000 is factory set to English the following three language settings are available by adjusting the dip switches 1 2 at the top of the board A ON setting is down and toward the board Please use a pen or pencil to gently move the switch as required See Fig 3 Language 1 2 3 4 35 6 J 7 8 oL LLL French OFFJON o S Jo 00 Jo o To activate the component test set Dip Switch 5 to ON This should NEVER be done unless directed to do so by Hayward Technical Service For 2 Speed pumps set Dip Switch 3 to ON Special wiring required See FIG 6 To activate the timer cycle set Dip Switch 4 to ON To activate the Booster Pump Timer Set Dip Switch 6 to ON Dip Switch 7 1s for Welded Contactor settings and High lift situations See Page 19 Must be s
33. hat hold the wires that go from the board to the contactor on the contactor Loosen the ground screw retaining the green wire from the board to the box Remove and save the six screws holding the board in the box Carefully lift the board from the box It is recommended that the 4mm tubing be replaced when the board is replaced Carefully replace the board secure with the 6 screws and reconnect all the wires Do not forget the jumper on the stop connections CHECK VOLTAGE ON SWITCH MATCHES REQUIREMENT USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 17 of 24 STRATUM Model VR1000 P N ISVRIOOOTECH Rev J RUN amp RECORD SHEET See page 8 Run in pool and spa mode with valves in normal configuration all the skimmers open to determine the lowest and highest operating vacuums with a CLEAN filter NOTE If the vacuum levels do not change when the valves are changed the saddle position should be checked to assure that the vacuum pick up of the STRATUM is in the correct location relative to the pump suction inlet See Figure 1 and Illustrations below Stable Vacuum in Pump Operating in Unprotected Mode POOL Mode Fully open suction through Main Drains amp Open Skimmers Dedicated Suction Lines Closed Heater bypass fully open All pool returns water features fully open SPA Mode Fully open suction through Main Drains amp Open Skimmers Heater bypass fully open All spa returns water features fully open Add 5 to higher
34. here is a loss of power This screen is designed to be used by the Hayward Technician and to determine what fault was recorded at pump shut down The Codes for Faults are listed on the following pages Please answer No A Yes will result in the screens at the bottom of the page Pinch the tube fully by crimping carefully with cloth or other protective material in the jaws of pliers Start with function default 2 increasing by 1 only if needed until the solenoid valves clicks indicating the system has recognized a pinched tube The Pinch Maybe setting should be increased until the system recognizes that the tube has been pinched This number is the natural vacuum changes while the pump is running If the system continues to click and click with the line NOT pinched the value should be decreased or reset to 2 SKIP THIS SCREEN S Up Pinch Dif is the amount of vacuum needed at startup before pulsing needed to know the tube is not blocked The factory setting on this can generally be used The system determines if the tube is truly blocked by looking for a drop in vacuum after it pulses the solenoid valve The Pinch Fail is the drop in vacuum 20 1 Hg Unless the system does not stop after the Pinched tube maybe occurs this should not be changed If the system shuts down as soon as the line is pinched this value should be reset to at least 20 The Pinch Vacuum Tube Test MUST be turned on to allow this function to op
35. ilure to do so may cause reverse rotation of motor and consequent serious pump damage Close air relief valve after pump is primed USE ONLY HAYWARD GENUINE REPLACEMENT PARTS mm HAYWARD Pool Products Pomona CA Clemmons NC Nashville TN EB a Hayward Industries Inc Company Tel 908 351 5400 www haywardpool com Page 14 of 24 STRATUM Model VR1000 P N ISVRIOOOTECH Rev J CUSTOM INSTALL PROCEDURES Hayward recommends that the VR1000 be initially run in UNPROTECTED MODE to allow initial vacuum readings be observed Certain settings can be adjusted to assure the VR1000 will not effect the normal operation of an installed pool or spa Select Pool Tech Mode Y N Custom Install Procedure X X Change High Vac Value Y N Inches of Hg 12 High Vacuum XX Inches Hg Is pump below Water level Y N Disconnect Vacuum Tube OK Calibrating Reconnect Vacuum Tube OK Y 1ISVAC N 208 230 VAC Reset 1 Stab Occurred Y N Initial Set up Complete Y N When this screen 1s shown pushing the MENU button twice rapidly can enter CUSTOM INSTALL PROCEDURES mode System is going into Custom Install The X X is the level of the code in the system This screen displays for about 5 seconds The system has a factory setting High Vacuum setting of 12 Hg From the Run and Record worksheet Page 17 adjust the High Vac to the number calculated The UP button will increas
36. in suction outlets Limb Entrapment A limb inserted into an opening of a suction outlet or suction outlet cover that is damaged broken cracked missing or not securely attached can result in a mechanical bind or swelling of the limb Body Suction Entrapment A differential pressure applied to a large portion of the body or limbs can result in an entrapment Evisceration Disembowelment A negative pressure applied directly to the intestines through an unprotected suction outlet sump or suction outlet cover which is damaged broken cracked missing or unsecured can result in evisceration disembowelment Mechanical Entrapment There is potential for jewelry swimsuit hair decorations finger toe or knuckle to be caught in an opening of a suction outlet or suction outlet cover resulting in mechanical entrapment USE ONLY HAYWARD GENUINE REPLACEMENT PARTS mT HAYWARD Poo Products Pomona CA Clemmons NC Nashville TN ies 5 Hayward Industries Inc Company Tel 908 35 l 5400 www haywardpool com Page 3 of 24 STRATUM Model VR1000 P N ISVRIOOOTECH Rev J A WARNING To reduce the risk of entrapment hazards o When suction outlets are less than a 18 x 23 equivalent a minimum of two functioning ASME112 19 8 suction outlets per pump must be installed Suction outlets in the same plane 1 e floor or wall must be installed a minimum of three feet 3 1 meter apart as measured from near point to near point o Dual suction o
37. inch USE ONLY HAYWARD GENUINE REPLACEMENT PARTS rm id AYWARD Pool Products Pomona CA Clemmons NC Nashville TN BER Haywrard Industries Inc Company Tel 908 351 5400 www haywardpool com Page 4 of 24 STRATUM Model VR1000 P N ISVRIOOOTECH Rev J General Information The VR1000 Vacuum Release System is designed as a pump controller The system will protect pool and spa equipment from certain known mechanical failures such as clogged drains and pipe breakage which can cause premature pump motor failure The system monitors and recognizes a change in pressure and electrical power When a change occurs it will shut down the pump and vent the suction line Automatic soft start should provide notice to swimmers or bathers on pump startup The VR1000 meets the requirements of ASTM Specification F2387 04 Meets ASME Standard 112 19 17 Meets UL standard 1563 as well as certified to Can CSA Std C27 2 No 218 1 The VR1000 system will automatically restart in most instances Should a manual restart be required pressing the OK button will restart the system Unprotected Mode can be entered after restart by holding NO amp OK buttons Unprotected mode lasts 30 minutes providing NO protection for swimmers or bathers DO NOT ALLOW SWIMMERS OR BATHERS IN THE POOL OR SPA WHEN THE SYSTEM IS IN UNPROTECTED MODE For proper installation and to avoid unnecessary service calls read this manual carefully and comp
38. ions that are unpredictable and unsafe The NOTICE label indicates special instructions that are important but not related to hazards USE ONLY HAYWARD GENUINE REPLACEMENT PARTS am HAYWARD Pool Products Pomona CA Clemmons NC Nashville TN BE A Hayward Industries Inc Company Tel 908 351 5400 www haywardpool com Page 2 of 24 STRATUM Model VR1000 P N ISVRIOOOTECH Rev J READ AND FOLLOW ALL INSTRUCTIONS IN THIS SERVICE AND INSTALLATION MANUAL AND ON EQUIPMENT IMPORTANT SAFETY INSTRUCTIONS Before installing or servicing this electrical equipment turn power supply OFF KEEP SAFETY LABELS IN GOOD CONDITION AND REPLACE IF MISSING OR DAMAGED A WARNING To reduce risk of injury do not permit children to use or climb on the pumps and filters Closely supervise children at all times Components such as the filtration system pumps and heaters must be positioned to prevent children from using them as a means of access to the pool A CAUTION This vacuum release system is intended for use on permanently installed swimming pools and may also be used with hot tubs and spas Do NOT use with storable pools A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity Though this product is designed for outdoor use
39. letely A WARNING This product should be installed and serviced only by a qualified professional Failure to install and or operate according to defined instructions and or use of non Hayward replacement parts will void the warranty CAUTION Al electrical wiring MUST be in conformance with all applicable local codes regulations and the National Electrical Code NEC Introduction This manual contains information for the proper installation and operation of the Hayward VR1000 Vacuum Release System The instructions in this manual MUST be followed precisely NOTICE ALL PRESSURE TESTING OF THE SYSTEM MUST BE COMPLETED BEFORE INSTALLING THE STRATUM NOTICE The filter must be cleaned or cartridge replaced before installing the STRATUM M NOTICE The STRATUM is rated for 115 VAC 50 60Hz for up to a 1 horsepower pump motor or 208 230 VAC 50 60Hz for up to a 3 horsepower pump motor TYPICAL INSTALLATION CONFIGURATION ELECTRICAL VR1000 DISCONNECT CONTROL SYSTEM ELECTRIC POWER VENT PLUG POWER TO PUMP VACUUM FROM POOL SUCTION LINE SIRE SKIMMER VALVE i TO FILTER POOL aa Fil AYWARD Pool Products Pomona CA Clemmons NC Nashville TN E of A Hayward Industries Inc Company Tel 908 35 l 5400 www haywardpool com Page 5 of 24 STRATUM Model VR1000 P N ISVRIOOOTECH Rev J Installation Instructions DIP Switches Battery BR2032 SADDLE CLAMP ASSEMBLY E amp E om EATA I Saddle
40. m The system should restart Under Vacuum Window indicates a problem with the inlet water flow to the pump Low volume flow can be caused by line breaks or low water levels The system should restart High Vacuum Alert indicates the system has stopped the pump vented and set off the alarm CUSTOMER ACTION IS REQUIRED Clear the cause of the problem Then press the OK button to restart the system System Won t Stabilize indicates the system has stopped the pump three times and set off the alarm CUSTOM ACTION IS REQUIRED Clear the cause of the problem Then press the OK button to restart the system Too Many Sen Sol Errs Or No Prime indicates the system has vented and stopped the pump three times and set off the alarm CUSTOM ACTION IS REQUIRED Clear the cause of the problem Then press the OK button to restart the system USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona CA Clemmons NC Nashville TN Tel 908 351 5400 www haywardpool com Page 10 of 24 STRATUM Model VR1000 P N ISVRIOOOTECH Rev J CUSTOMER ACCESSIBLE MODES To initiate a self test through the use of the push buttons on the display push button OK MENU and release This only causes the system test in RUN MODE The self test is run by the customer just to confirm the VR1000 is actively protecting the pool spa The system should restart and stabilize SET TIME AND DATE Y N Set the time of day clock In normal operation
41. ntly connected to GFCI WARNING Failure to bond pump to pool structure will increase risk for electrocution and could result in injury or death To reduce the risk of electric shock the electrician must comply with installation instructions and must bond the pump accordingly In addition the electrician must also conform to local electrical codes for bonding requirements Notes to the electrician Use a solid copper conductor size 8 or larger Run a continuous wire from external bonding lug to reinforcing rod or mesh Connect a No 8 AWG 8 4 mm solid copper bonding wire to the pressure wire connector provided on the motor housing and to all metal parts of swimming pool spa or hot tub and to all electrical equipment metal piping except gas piping and conduit within 5 ft 1 5 m of inside walls of swimming pool spa or hot tub IMPORTANT Reference NEC codes for all wiring standards including but not limited to grounding bonding and other general wiring procedures NOTE The National Electrical Code NEC permits use of a cord with a maximum 3 ft 1 m length If your pump is equipped with a cord complying with the NEC the preceding four 4 hazards apply WARNING Suction Entrapment Hazard Suction in suction outlets and or suction outlet covers which are damaged broken cracked missing or unsecured can cause severe injury p and or death due to the following entrapment hazards Hair Entrapment Hair can become entangled
42. r larger Run wire from external bonding lug to reinforcing rod or mesh Connect a No 8 AWG 8 4 mm solid copper bonding wire to the pressure wire connector provided on the motor housing and to all metal parts of swimming pool spa or hot tub and to all electrical equipment metal piping except gas piping and conduit within 5 ft 1 5 m of inside walls of swimming pool spa or hot tub Wiring WARNING All electrical wiring MUST be in conformance with all applicable local codes regulations and the National Electrical Code NEC Pump MUST be permanently connected to circuit If other lights or appliances are also on the same circuit be sure to add their amp loads before figuring wire and circuit breaker sizes Use the load circuit breaker as the Master On Off switch Install a Ground Fault Circuit Interrupter GFCT in circuit it will sense a short circuit to ground and disconnect power before it becomes dangerous to pool users For size of GFCI required and test procedures for GFCI see manufacturer s instructions In case of a power outage check GFCI for tripping which will prevent normal pump operation Reset if necessary NOTE If you do not use conduit when wiring motor be sure to seal wire opening on end of motor to prevent dirt bugs etc from entering USE ONLY HAYWARD GENUINE REPLACEMENT PARTS m HAYWARD Goo Products Pomona CA Clemmons NC Nashville TN ui A Hayward Industries Inc Company Tel 908 35 5400 www
43. rime after trying for nn minutes ET 14 Menu key pushed in startup pulsing ET 7 15 Booster Pump turned ON by timer 4 8 bit parms On Min amp Sec followed by Off Min amp Sec ET 16 Booster Pump turned OFF by timer 4 8 bit parms On Min amp Sec followed by Off Min amp Sec ET 17 Spare switch closure detected run pump in high speed mode continuously ET 18 Spare switch opening after above closure detected return to normal operation USE ONLY HAYWARD GENUINE REPLACEMENT PARTS id AYWARD Poo Products Pomona CA Clemmons NC Nashville TN DB A Hayward Industries Inc Company Tel 908 351 5400 www haywardpool com Page 21 of 24 ET 7 19 ET 20 ET 21 EI ET 23 ET 24 ET 25 ET 26 EI 27 ET 30 ET 31 ET 32 ET 33 ET 34 ET 35 ET 36 ET 37 MEE Hayward Industries Inc Company HAYWARD Poo Products STRATUM Model VR1000 P N ISVRIOOOTECH Rev J Menu key pressed in timer off loop Stabilization Stop switch Stabilization Hi spike 2 parms in 16 bit ADC units Hi Spike Threshold amp actual trigger value Stabilization Run dry Stabilization No stabilization 5 tries Menu key pushed in stabilization Stabilized in Hg less than stabilization threshold which was determined at 1st Stab time 2 parms 16 bits ADC units stab amp threshold values Timer Override by Yes amp No key press while pumps were turned off by the timer Pumps will run in this mode for about 2 ho
44. rst timer cycle starting at midnight as the desired ON time and then the desired AM OFF time The second timer cycle should be set from the desired PM ON time to midnight as the OFF time EACH DAY MODE Note when each day mode is selected the timers must be set on a daily basis The week days will be stepped through to allow individual day setting USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona CA Clemmons NC Nashville TN Tel 908 351 5400 www haywardpool com Page 11 of 24 STRATUM Model VR1000 P N ISVRIOOOTECH Rev J b cA ril LL q T VRXIOOE Solenoid Valve 24 VAC 1 0 Fitting Kit with saddle fitting See Fig 2 VRXIOOF Vent Filter V NPTM Pack includes 8 tube amp fittings to extend tube above water level 5 16 Tubing x 25 Long See Fig 2 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Tr HAYWARD rool Products Pomona CA Clemmons NC Nashville TN Ei A Hayward Industries Inc Company Tel 908 351 5400 www haywardpool com Page 12 of 24 STRATUM Model VR1000 P N ISVRIOOOTECH Rev J Electrical WARNING Ground motor before connecting to electrical power supply Failure to ground pump motor can cause serious or fatal electrical shock hazard WARNING Do NOT ground to a gas supply line A WARNING TO AVOID DANGEROUS OR FATAL ELECTRICAL SHOCK TURN OFF POWER TO MOTOR BEFORE WORKING ON ELECTRICAL CONNECTIONS A WARNING Ground Fault Circuit Interrupter GFC
45. t Detected Clogged or Pinched Vacuum tube Contactor Failure am Sg hone Sf e After all the Custom Settings have been completed a test consisting of three simulated entrapments must be conducted to verify proper installation calibration and operation e Anentrapment can be simulated by partially closing or repositioning a valve so that there will be a change in the flow pattern That is changing the pattern of flow from the suction outlet Main Drain to the skimmer will simulate an entrapment e Field testing criteria to verify the release of a potentially entrapped bather is three simulated entrapments in which the VR1000 turns off the pump and vents the suction line within three seconds in each of the three simulations e Field testing criteria to verify the functioning of the pinched tube function is required This function determines if the system can determine if the pump is connected to the VR1000 vacuum tube when the pump is running e A ball butterfly or sliding gate valve shall be installed within 2 ft 0 6m upstream from the STRATUM between the STRATUM saddle for the vacuum tube and the protected suction outlet or a test mat shall be used to cover the suction outlet to simulate an entrapment event USE ONLY HAYWARD GENUINE REPLACEMENT PARTS aa Re AYWARD Pool Products Pomona CA Clemmons NC Nashville TN E a A Hayward Industries Inc Company Tel 908 35 5400 www haywardpool com Page 16 of 24 STRATUM
46. the time of day will be displayed on the LCD When the board is first powered up the time and date are displayed Pushing the Menu button will step through the date and time of day set up Pushing the NO will go to next step 5 Seconds of inactivity will go to next step Y ES follow screen instructions NOTE If system does not maintain date and time when the power fails or is disconnected replace the battery SET TIMER EVENTS Y N Y 7 Day Mode N Each Day Mode ON 04 00 AM OFF 08 00 PM OK Daily On Hour 4 AM Daily On Min l Daily Off Hour 6 AM Daily Off Min 0 Low Speed On 08 00 AM OK BST On 04 00PM Off 0400 PM OK On 0700AM Mon Off 0400PM OK Tue Mon OK Y N C HAYWARD bo Products meee A Hayward Industries Inc Company The timer events are used to control the ON and OFF times of the Filter Pump Booster Pump and Low Speed on a two speed Pump Dip switch 4 Must be on to allow the timers to be set A YES will allow the following timer settings Note Timers run 12 01 AM Midnight to 11 59 PM YES 7 day all the week long the pumps will run at the same times NO Each days timers must be set The 7 day time clock has two 2 on off programs per day while each day only has one program All time clocks are selected either as 7 day or each day If each day is selected you will need to program ON times for every day and
47. urs Operator has indicated status of the drain cover First 8 bit parm 0 operator says cover is NOT installed 1 it IS installed This occurs in the Pool Tech Mode procedures Run Stop switch RUN Rate of change error vacuum rising too fast 2 parms in 8 bit ADC units difference threshold and actual difference detected Run detected pinched vacuum hose 3 16 bit ADC value parms Before vent after vent difference threshold Run Hi vacuum window 2 parms in 16 bit ADC units Hi window threshold amp actual trigger value detected Run Lo vacuum window 2 parms in 16 bit ADC units Hi window threshold amp actual trigger value detected Run periodic SS test initiated Run Sensor Solenoid failure periodic test Run possible pinched vacuum hose test to see if it is run a test similar to periodic SS test 1 8 bit parm difference in ADC units Hi Lo Pinch Count readings Note that 2 or less is a possible pinched line and further testing is done USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona CA Clemmons NC Nashville TN Tel 908 351 5400 www haywardpool com Page 22 of 24 ET 38 ET 39 ET 40 ET 41 ET 42 ET 50 ET 51 ET 52 ET 53 ET 54 ET 55 ET 56 ET 57 MEE Hayward Industries Inc Company HAYWARD Poo Products STRATUM Model VR1000 P N ISVRIOOOTECH Rev J Start up detected pinched vacuum hose 1 8 bit ADC count parm or case in
48. using filter manual air relief valve See filter owner s manual for more detail A WARNING If pump is being pressure tested 40 PSI MAXIMUM be sure pressure has been released before removing strainer cover Priming Pump CAUTION All suction and discharge valves MUST be OPEN as well as filter air relief valve if available on filter when starting the circulating pump system Failure to do so could result in severe personal injury Release all pressure from filter pump and piping system See filter owner s manual f water source is higher than the pump pump will prime itself when suction and outlet valves are opened If water source 1s lower than the pump unscrew and remove strainer cover fill strainer housing with water Clean and lubricate strainer cover O ring with Jack s 327 each time it is removed Inspect O ring and re install on strainer cover Replace strainer cover on strainer housing turn clockwise to tighten cover NOTE Tighten strainer cover by hand only no wrenches Turn on power and wait for pump to prime which may take up to five 5 minutes Priming time will depend on vertical length of suction lift and horizontal length of suction pipe If pump does NOT prime within five minutes stop motor and determine cause Be sure all suction and discharge valves are open when pump is running See pump owner s manual for Troubleshooting Guide A ATTENTION wait five 5 seconds before re starting pump Fa
49. utlets shall be placed in such locations and distances to avoid dual blockage by a user o Dualsuction fittings shall not be located on seating areas or on the backrest for such seating areas o The maximum system flow rate shall not exceed the flow rating of any listed per current revision of ASME ANSI A112 19 8 suction outlet cover installed o Never use the Pool or Spa if any suction outlet component is damaged broken cracked missing or not securely attached Replace damaged broken cracked missing or not securely attached suction outlet components immediately o Inaddition two or more suction outlets per pump installed in accordance with latest APSP formally NSPI Standards and CPSC guidelines follow all National State and Local codes applicable O This vacuum release system is designed to prevent body suction entrapment but not evisceration A WARNING Failure to remove pressure test plugs and or plugs used in winterization of the pool spa from the suction outlets can result in an increase potential for suction entrapment as described above A WARNING Failure to keep suction outlet components clear of debris such as leaves dirt hair paper and other material can result in an increase potential for suction entrapment as described above A WARNING Suction outlet components have a finite life the cover grate should be inspected frequently and replaced at least every ten years or if found to be damaged broken
50. with the motor starters See Illustration below FIG 8 Connect a ground wire from the primary electrical panel to the VR1000 and connect the system to the pool bonding system by an 8AWG 6AWG for Canada wire A lug for bonding is provided on the outside bottom of the enclosure Connect incoming power to 2 amp 6 on the power relay s See FIG 7 Assure that the earth ground wire connector between the conductors is secured Optional If a remote stop button is used remove jumper from terminal pair marked STOP Switch The switch must be a locking type STOP switch with a normally closed set of contacts in the UP position Install the STOP switch across the terminals where jumper was located A Steward 28A0640 0A0 1 2 turn ferrite core or equal must be added to the stop switch cable within 2 of the outside of the STRATUM box Stop switch can be Square D KR9RH6 or equivalent mounted in a rain tight box Optional If a remote alarm is to be installed the terminals Buzzer are connected to an alarm relay which will supply a closed contact rated at 115 VAC 5 amp when the system alarm trips External power must be supplied for the alarm to sound Can be used with Audible Alarms from Federal Signal Model 350 120 30 or equivalent available from Grainger The terminal marked SPARE when connected to the terminal marked GROUND will turn the pump on to High Speed and maintain the High Speed mode until these two
Download Pdf Manuals
Related Search
Related Contents
Manual Cover Pages Télécharger cette fiche au format PDF MANUALE D`ISTRUZIONI Conventional Rack and Pinion Power Steering Operation LE POINT SUR. 3r 3 Electro-Voice MB100 User's Manual propriete intellectuelle, exploitation industrielle : mode d`emploi Aviom AN-16/i Manual Copyright © All rights reserved.