1. Animals Delete Download 2000 01 08 23 19 32 2 x CE 1082251 LOG 2000 01 08 22 51 02 1 X H GPS location 5202 2113 H 00637 5422 E 984000711435048 2000 01 08 23 19 48 999000000667565 2000 01 08 23 20 01 A new data file is automatically created at midnight and after a power down Please note it s a static webpage To see new numbers click refresh or press F5 VP1850 200PM 00GB Panel reader Manual version 1 2 Page 8 9 1 0 0 1 red light s on identification possible Find source of the background noise in but reduced performance caused by the Panel reader area that disturbs the SS lt jp Malfunctions and disposal Trouble shooting Check the operation of the VP1850 Panel reader regularly with a few tag s Check the actual state of the Panel reader The Panel reader led lights will show if there are any malfunctions The Panel reader led lights will show if the system is working correctly or not Green Red Display VP1850 Panel reader light light O Both Both OK ON OFF Check the cause of the malfunction and solve it Problem What How to check or re install See 1 green ae on reduced antenna field Antenna tuning Remove the iron from caused by some iron Identification the Panel reader area possible but reduced performance 2 flashing green lights no correct Antenna tuning Remove the iron from antenna field caused by a lot of iron the Panel reader area Identificati
2. Username Password Retype password gt Settings authentication 4 Change the RS232 and Bluetooth settings in the Settings screen if necessary and press Submit The network settings have been made in 3 2 Network IP Address Subnet Mask Default Gateway Sd gt P Settings RS232 Baudrate Databits Parity Stopbits Bluetooth Bluetooth ame Bluetooth Pincode The default RS232 settings are Baud rate 9600 Data bits 8 Parity None and Stop bits 1 The default Bluetooth name is BlueMod B20 4a and the default security pin code is 0000 These settings can be changed VP1850 200PM 00GB Panel reader Manual version 1 2 Page 7 SS lt 5 Operation The Panel reader web server data program can be opened and operated on a PC Click on the web server shortcut icon on the desktop mil to start the web server program if available or open the web browser with the IP address set with the IP Utility wizard factory default http 10 10 10 10 gt P1850 PanelReader Windows Internet Explorer G AM E http 10 10 10 10 i File Edit View Favorites Tools Help ww E vP1350 PanelReader A list of filenames is shown in the data page The last created data log file is shown at the top Click on a filename to look at the content of a file The data can be downloaded or deleted Click on download to download the data to another web page Here you can select and copy data Filename Created
3. Del 9 2 6 6 1 6 2 Appendix A Technical specifications 111 22010 Appendix B Wiring Panel reader cccccccsssssseeeeeeenseeseeeneneeesees Appendix C Corridor requirements Introduction i Description anname FUNCUOLIN O meine Mounting the VP1850 Panel reader 11 21 11vvs Starting upoperation L a aa Connecting the VP1850 Panel reader Setting up the network configuration Setting up the VP1850 Panel reader software ODETI la Malfunctions and disposal nnnsnnnnnnnnnnnnnnnnnnnnnnnnnnnas Trouble SNOQUAG 2 sionismi a rmk aima am i Resetting the VP1850 Panel reader Maintenance and disposal nnnnnnenunnnnnnnnnnnnnnnnnnnnnnnnnnas MAIS MAN GE stain tae miil kaa aimamisi kaa noa mid va LIS 61075721 EA paio lari pirata VP1850 200PM 00GB Panel reader Manual version 1 2 1 1 1 2 SS lt j Introduction The VP1850 Panel reader identifies RFID ear tags attached to individual animals The identification can be used for registration of the animals that have passed the VP1850 Panel reader unit A weight scale can optionally be connected to the Panel reader This device complies with Part 15 of the FCC Rules and to RSS 210 of Industry Canada Operation is subject
4. per installation It depends on the iron and the background noise in the panel pe reader area VP1850 200PM 00GB Panel reader Manual version 1 2 Page 15 a VP1850 200PM 00GB Panel reader Manual version 1 2 Page 16 Nedap LivelD PO Box 104 7140 AC Groenlo The Netherlands T 31 544 471 100 F 31 544 466 839 info nedap liveid com www nedap liveid com Manage your livestock
5. shielding orange and orange white wires each colour to one connector block point 78 6 l l l Wiring scheme Panel reader cable 2 Connector number Velos Panel reader cable art nr 7707029 1 Red Not connected 2 Black Minus 3 Blue FDX in F synchronization FDX in 4 Blue White FDXout F synchronization FDX out Shield 2 Shielding 5 Orange HDX HDX synchronization 6 Orange White HDX HDX synchronization 7 Green Output Buzzer 4 8 Green White Output Buzzer 10 24 V VP1850 200PM 00GB Panel reader Manual version 1 2 Page 14 SS lt 5 Appendix C Corridor requirements The maximum corridor width at the Panel reader location will be different for each animal sort and breed Make sure the corridor is not too wide at the Panel reader location AN The maximum width of the corridor is essential to achieve a proper working system Animals should never be able to pass each other turn around or walk in the wrong direction Maximum corridor entrance width Allow passage of 1 animal at the time Keep the corridor as narrow 1 gt i Maximum width as possible 1 animal wide RFID Eartags Attach all ear tags on same side of animals left in IN this example The antenna must be mounted at the side where the tag is attached 00 Cc a Pc a The identification distance of the a 2 antenna field al gs i I The identification distance of the antenna varies
6. to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Description The VP1850 Panel reader system consists of a Panel reader unit that is connected to an adaptor a PC or a network or optionally a weight scale Weight 1 VPI 850 Panel reader unit 2 scale O 2 Adaptor pa 3 PC 4 Optional Weight scale 5 Blue tooth ti J 63 O Blue tooth connection gt 6 6 GPS connection Figure 1 Overview VP1850 Panel reader system Functioning The VP1850 Panel reader creates a magnetic field around the antenna that is used to identify the tags on ISO frequency 134 2 kHz The Panel reader antenna identifies RFID ear tags attached to individual animals that pass the Panel Reader unit The identification is indicated with five blue burning led lights in the top of the Panel reader Figure 2 ldentification blue led lights VP1850 200PM 00GB Panel reader Manual version 1 2 Page 1 _e c_de _a When an animal is identified in the Panel reader antenna the responder number will be stored The responder number will be shown in the web server program A PC or a network is used to access the web server and the Internet worldwide It does not have to be connected all the time T Kd unit Filename Created Animals Delete Download 2 Re S po nde r num b er 2081210 LOG
7. 2010 02 08 12 10 42 88 X H an ma iden ti ficatio n les nni 3 Data in web server GPS location 000000000 0 0000000000 0 a p rog ram 984000000321934 2010 02 08 12 10 42 984000000321934 2010 02 08 12 10 51 984000000321934 2010 02 08 12 11 00 984000000321934 2010 02 08 12 11 03 984000000321934 2010 02 08 12 11 05 Figure 3 Connection between VP1850 Panel reader and web server program VP1850 200PM 00GB Panel reader Manual version 1 2 Page 2 SS lt 5 Mounting the VP1850 Panel reader See Appendix A for technical specifications before mounting See Appendix C for corridor requirements AN Mounting reguirements 1 The Panel reader must be mounted at the side where the ear tags of the animals are attached 2 The Panel reader must be mounted on a wall close to a stable power supply 3 The Panel reader must not be mounted close to any iron Iron will affect the performance of the antenna 4 The Panel reader must be mounted gt 1 5 m from electrical cables or power supply transformers 5 The Panel reader must not be mounted close to electrical equipment e g a power supply with background noise This can disturb the antenna 6 The Panel reader may not be exposed to direct sunlight Mount the VP1850 Panel reader unit firmly on a wall or at a non metal frame 1 Drill 10 and at least 50 mm deep holes to mount the Panel reader in the 4 positions indicated in the picture below 2 Use the bolts that
8. C Transport storage temperatures 40 C 70 C Humidity rh 45 C 85 Enclosure protection class when cover and cables installed correctly IP67 The Panel reader may not be exposed to direct sunlight The Panel reader must always be transported and stored dry and frost free VP1850 200PM 00GB Panel reader Manual version 1 2 Page 12 SS 1 jv Appendix B Wiring Panel reader Wiring scheme Panel reader cable 1 Connector number Velos Panel reader cable art nr 7707029 1 Red 2 Black 3 Blue Tx 4 Blue White Tx Shield 1 5 Orange Rx 6 Orange White Rx 7 Green TxD 8 Green White RxD Wiring scheme Panel reader cable 2 12 48V Ethernet 10 Mb Tx Ethernet 10 Mb Tx Shielding Ethernet 10 Mb Rx Ethernet 10 Mb Rx RS232 TxD RS232 RxD Connector number Velos Panel reader cable art nr 7707029 Red Black Blue FDX in Blue White FDXout Shield all Orange HDX Orange White HDX Green Green White AUN OO N 0 VI VP1850 200PM 00GB Panel reader Not connected Minus F synchronization FDX in F synchronization FDX out Shielding HDX synchronization HDX synchronization Output Buzzer Mi Output Buzzer 10 24 V Manual version 1 2 Page 13 SS m jv Wiring more than one Panel reader Connect all cables with number 2 to a Connector block Connect the 1 blue white wire and the 2 and 3 blue wires to one connector point Connect all 3 black
9. Service manual For installation operation and service Panel Reader VP1850 Manual article number 5277027 February 2011 Manual version 1 2 live Manage your livestock SS lt jv Preface This manual describes the installation operation troubleshooting and maintenance of the VP1850 Panel reader Read this manual entirely and when installing carefully follow the instructions step by step as described in the manual Pictograms AN Please pay extra attention here This pictogram indicates an important subject Version overvieW Manual version 1 0 May 2010 First release Manual version 1 1 October 2010 Wiring adjusted Manual version 1 2 February 2011 IP utility wizard instructions for CD adjusted This information is furnished for guidance and with no guarantee as to its accuracy or completeness its publication conveys no license under any patent or other right nor does the publisher assume liability for any consequence of its use specifications and availability of goods mentioned in it are subject to change without notice it is not to be reproduced in any way in whole or in part without the written consent of the publisher Nedap N V AGRI P O Box 104 NL 7140 AC GROENLO The Netherlands VP1850 200PM 00GB Panel reader Manual version 1 2 SS lt jp Table of contents Preface and Version overview Table of contents 1 1 1 1 2 2 3 3 1 3 2 3 3 4 9
10. are supplied with the unit to mount the Panel reader Use the 4 big bolts for a wall or the 4 smaller ones for a metal surface For wall Bolt washer spacer and plug 4x A Bolt M8x80 DIN 571 2 Plain washer M8 DIN 9021 3 Spacer 4 Nylon plug 10x50 For metal Bolt washer and spacer 4x B Bolt M6 3x50 DIN 7504 2 Plain washer M8 DIN 9021 3 Spacer Figure 4 Mounting positions for the VP1850 Panel reader AN General remark Don t drill through the Panel reader This could damage the electronics and affect the functioning of the Panel reader VP1850 200PM 00GB Panel reader Manual version 1 2 Page 3 3 1 mie lt jp Starting up operation The VP1850 Panel reader is pre tuned and ready for use Connecting the VP1850 Panel reader Connect the VP1850 Panel reader to a PC or a weight scale through an RS232 connection or to a PC or router through a LAN or Bluetooth connection The Panel reader is already connected to the adapter through the connector The adapter is optionally used when connected to a weight scale depends on weight scale type See appendix B for a wiring scheme of the Panel reader cable Weight 1 RS232 connection with FI scale PC ar ego A eg 2 RS232 connection with i weight scale or other device and optional adaptor 3 Bluetooth or LAN connection with PC j 4 LAN connection with router Figure 5 Overview VP1850 Panel reader system to be conne
11. cted Connect the VP1850 Panel reader to a PC or a network and optionally to a weight scale AN Install cables and power supplies transformers gt 1 5 m from the Panel reader if possible 3 Connect a PC to the Sub D connection from the connector if there is no weight scale or connect a PC via the Bluetooth or LAN connection or connect a network via the LAN connection 4 Optionally connect a weight scale to the Sub D connection from the connector Put the adaptor into an electric socket 6 Checkthe operation of the Panel reader on Use an extension cable art nr 7707037 of 4 meters to extend the Velos Panel reader cable if necessary Ps VP1850 200PM 00GB Panel reader Manual version 1 2 Page 4 SS lt 5 3 2 Setting up the network configuration Make sure the VP1850 Panel reader is connected to the network and is operating Take the IP Utility wizard CD and run it on the connected PC to set the IP address correctly 1 Click on the IP utility wizard icon from the IP wizard CD JA 2 Turn off the fire wall in the Control panel Security centre and click Next Ce Cass 3 Click Next Your PC has the following network configuration IP address 192 168 10 200 Subnet mask 255 255 0 0 Default gateway Preferred DNS server CJ ona Click on copy advice if this is suggested and click Next Your device has the following network configuration This wizard adv
12. he clock time in the screen Settings gt Clock and press Submit Press refresh or F5 to get the new value from the Panel reader Real time clock Year Month e Day Hour 9 Minute 52 Second 2 Change the output and storage protocol if necessary in the screen Settings gt Protocol and press Submit The output and storage settings will influence the output data that will be send by the RS232 and the Bluetooth every time a number is read Output Iso O ISO Extended Stx A RUU VVV CCC XXKXXXXXXXXX Cr Lf O Hedap gt Settings Storage protocol Recognition Time in 100 msecs Store double tags No The default and recommended output setting is ISO extended Output protocol e ISO output data send according ISO standards e ISO Extended output data send according to ISO standards including timestamp e Nedap output data send according to Nedap Velos protocol For advanced user In UDP the number is sent real time The default and storage settings are Recognition time 5 and store double tags No e Store double tags Yes store the identification time of double tags in the same file e Store double tags No store only the last identification time VP1850 200PM 00GB Panel reader Manual version 1 2 Page 6 oS lt jv 3 Optionally enter a user name and password Especially when the Panel reader is integrated in a network this is advised Authentication Use authentication ha
13. ices the following changes IP address 10 10 10 10 Set the IP address of the device to 192 168 10 157 Change the subnet mask to 255 255 255 0 Subnet mask 255 255 255 0 Default gateway Preferred DNS server Ci Copy advice L Ce Ca If the VP1850 Panel reader is not found check if the Panel reader is running and if the network is connected correctly Click Back and try again Contact a network specialist if necessary Click Next The IP address will now be changed and a web server program shortcut will be created on the desktop The wizard will apply the following changes i IP address of the device will be set to 192 168 10 157 Create desktop shortcut Ce Ca Click OK 6 Click on OK and on Finish The configuration is set the device will now reboot You can browse to the device on http 192 168 10 157 etek Ja ns 7 The web server program shortcut is now on the desktop Click on it to start the program il VP1850 200PM 00GB Panel reader Manual version 1 2 Page 5 3 3 SS lt 5 Setting up the VP1850 Panel reader software Click on the web server shortcut icon on the desktop mill to start the web server program if available or open the web browser with the IP address set with the IP Utility wizard factory default http 10 10 10 10 GE v http 10 10 10 10 File Edit View Favorites Tools Help w ope E vP1350 PanelReader 1 Set t
14. on possible but a very much reduced performance electrical equipment with background antenna e g a power supply noise Possibly cable or power supply fluorescent lightning another antenna transformer lt 1 5 m from the Panel or a frequency controller Delete it or reader turn it off 2 red light s on strongly reduced Find source of the background noise in performance caused by a no the Panel reader area that disturbs the synchronisation with a nearby HDX antenna e g a power supply reader or electrical equipment with fluorescent lightning another antenna strong electrical background noise or a frequency controller Delete it or Possibly cable or power supply turn it off Install cables and power transformer lt 1 5 m from the Panel supply transformer gt 1 5 m from the reader No identification possible Panel reader if possible Blue ooh pinco no ent carey not on no signal or blue Check the pin code 3 3 tooth aa pinco no ent carey not entered correctly Yellow light not on no GPS signal in If indoors move Panel reader outdoors the area or building If outdoors no GPS signal available VP1850 200PM 00GB Panel reader Manual version 1 2 Page 9 SS lt ra 5 2 Resetting the VP1850 Panel reader If necessary set the VP1850 Panel reader back to its factory defaults 1 Turn on the power 2 Puta magnet on the spot indicated on the back of the Panel reader with a circle on the sticker and kee
15. p it there A row of blue leds will light up when the magnet is in the correct position 3 Turn off the power and turn it back on The row of blue leds will light up again 4 Remove the magnet from the Panel reader 5 Turn off the power and turn it back on again The Panel reader is now set back to its factory defaults AN The IP address now is 10 10 10 10 again like in the beginning See chapter 3 to start up the operation again by setting the network configuration and the software settings VP1850 200PM 00GB Panel reader Manual version 1 2 Page 10 6 1 6 2 rae c a par Maintenance and disposal Maintenance Check the operation of the VP1850 Panel reader regularly No regular maintenance is required The Panel reader can be cleaned with water and sponge Avoid aggressive cleaning liquids Disposal At discard dispose of materials from the Panel reader in accordance with the current environmental rules of the state or local governing authorities VP1850 200PM 00GB Panel reader Manual version 1 2 Page 11 mie lt jp Appendix A Technical specifications Measurements VP1850 Panel reader Total height Total width Depth Specifications for transport installation Electrical supply Main supply 100V 240V Freguency 50 60 Hz Input voltage use Nedap power supply 12 48V DC Input current mA depends on input voltage without buzzer 1 0 5A Environmental Operating temperatures 10 C 45