1. and will also increase the volume used impacting the recorded values in Diagnostics Steps 3D 4D and 5D and Valve History eu Step 4VH The third display shows the current treated water flow rate FLOW RATE through the system The fourth display will display contact screen i f B EPN information if it was edited The fifth display will show either dP I or hold if the dP switch is closed The sixth display indicates the user should call for service The service display will not appear if OFF is selected in Step 12S of OEM Softener System Setup To clear the Service Call reminder press the A and Y buttons PURITAN WATER 5295093 ul simultaneously while the number and banner text screen is REGENERATION REGENERATION displayed D P or H 0 LD If the system has called for a regeneration that will occur at the preset time of regeneration the words REGEN TODAY will gt VALVE HOMING CALL XXXX FOR SERV alternate with the header on the display If a water meter is installed the water drop flashes on the display FRRO R 104 7555 5935555 when water is being treated i e water is flowing through the system SCHEDULED SERVICE ae CALL XXXX FOR SCHE 13595559 Regeneration Mode Typically a system is set to regenerate at a time of low water usage An example of a time with BACKWASH low water usage is when a household is asleep If there is a demand for wa
2. Softener Valve Programming Steps Set to ALTA Set to ALTB OEM Cycle Sequence Step4Cs Nv two pin wire connector tothe wo pin connections between the ALTE valve andthe MAV connector labeled MAV MTR on the ALTA valve are made Softener System Setup Step 8S Set to AUTO Set to AUTO Softener System Setup Step 9S Set regeneration time option to IMMEDIATE Set regeneration time option to IMMEDIATE Installer Display Setting Step 31 Set Days Between Regen to OFF Set Days Between Regen to OFF If set up for a filter in Step 7F set Volume Capacity in Step 9S select Regeneration Time Option IMMEDIATE and in Step 31 select Days Between Regen OFF Retracted Extended Valve A in Service Position Valve B in Service Position MAV MAV piston rod Retracted piston rod Extended Note Clack Twin Alternator Operations e Twin alternating systems can be programmed with a day override setting combined with the normal volume based regeneration programming A twin alternating system in this configuration will then regenerate based on the volume used or the day override if there is a period of low water usage e Twin alternating systems can be programmed as a time clock only based regenerating system In this configuration the days remaining are counted only on the unit that is in service The unit in Stand by Mode only not
3. if a connection is made to the two pin connector labeled DP SWITCH located on the printed circuit board STEP 6CS OFF Feature not used NOTE In a twin alternating system each control must have a separate dP signal or dP switch One dP signal or one dP switch cannot be used for both controls ON 0 REG If the dP switch is closed for an accumulative time of 2 minutes a regeneration will be signaled to the unit In a twin alternating system the MAV will transition first to switch units so that the signaled unit can start regeneration After the MAV is fully transitioned the regeneration begins immediately Note For WS1 WS2L control valves programmed for twin alternating if the dP function ON 0 REG is set the Delayed Rinse and Fill feature is not available DELAY REG If the dP switch is closed for an accumulative time of 2 minutes a regeneration will occur at the scheduled delayed regeneration time In a twin alternating system once the dP switch is triggered the PC Board will display REGEN TODAY and when the delayed regen time comes the control will switch tanks and the triggered unit will then go into regeneration Note For WS1 WS2L control valves programmed for twin alternating if the dP function DELAY REG is set the Delayed Rinse and Fill feature is not available HOLD REG If the dP switch is closed a regeneration will be prevented from occurring while there is switch closure In a twin alternating system the
4. or 1 25 V3070FF or V3070FM are not designed to be used with the alternator or separate source functions The V3063 and V3063BSPT motorized alternating valves are not designed to be used as a no hard water bypass or separate source inlet if the pressure differential is more than 60 psi SET Configuring the Control Valve for No Hard Water Bypass Operation Select nHbP for control operation For no hard water bypass operation the three wire connector is not used Selection requires that a connection to MAV or a Clack No Hard Water Bypass Valve is made to the two pin connector labeled MAV MTR located on the printed circuit board If using a MAV the A port of the MAV must be plugged and the valve outlet connected to the B port When set to nHbP the MAV will be driven closed before the first regeneration cycle that is not FILL or SOFTENING or FILTERING and be driven open after the last regeneration cycle that is not FILL NO HARD NOTE If the control valve enters into an error state during regeneration mode the no hard water bypass valve will remain in its current state until the error is corrected and reset Selecting the Control Valve to act as an alternator Prior to starting the programming steps connect the three pin wire to each control valve board s three pin connector labeled INTERCONNECT Also connect the meter cord to either control valve to the three pin connector labeled METER INPUT
5. Not Shown 1 V3186UK WS1 AC ADAPTER 220 240V 12V UK V3186 01 WS1 AC ADAPTER CORD ONLY Not Shown V3690 WSILP DRIVE BACK PLATE 1 Refer to Control Valve Service Manual for other drawings and part numbers Relay Specifications 12V DC Relay with a coil resistance not less than 80 ohms If mounting the relay under the cover check for proper mounting location dimensions on the backplate AC Adapter U S International Wiring For Correct On Off Operation Supply Voltage 120 VAC 230V AC PC Board Relay Terminal Block Relay Supply Frequency 60 Hz 50 Hz RELAY Coil Output Voltage 12 V AC 12 V AC COM Coil Output Current 500 mA 500 mA RELAY2 Coil When replacing the battery align Correct positives and push down to fully seat Battery lt Battery replacement is Orientation 3 volt lithium coin cell Battery Fully Seated type 2032 See page 6 for this button s function PR Manual Page 5 OEM General Programming Instructions The control valve offers multiple procedures that allow the valve to be modified to suit the needs of the installation These procedures are e OEM Configuration Setup e User Display Settings e OEM Softener System Setup e Diagnostics e OEM Filter System Setup e Valve History e Installer Display Settings Tables 1 and 2 show cycle order when the valve is set up
6. DIR Softeners there are two options for setting the Gallons Capacity The Gallons Capacity is automatically calculated if set to AUTO Reserve Capacity is automatically estimated based on water usage if AUTO is used The other option is to set the Gallons Capacity to a specific number If a specific number is set reserve capacity is Zero unless the value is manually set i e the manufacturer intentionally sets the gallon capacity number below the calculated capacity of the system A unique feature of this control valve is the ability to display actual water usage for the last 63 days The values are initially stored as This means the value is unknown As days pass values are stored as 0 for no flow or the actual number of gallons The counting of the gallons starts at the regeneration time If no regeneration time can be set i e when the valve is set for immediate regeneration the counting of gallons starts at 12 a m Day 1 is yesterday day 2 the day before yesterday etc As new values are added the oldest history disappears i vos SSS Auomascaty una vor TT o ao Another unique feature is that the valve automatically calculates a reserve capacity when set up as a softener with Gallons Capacity set to AUTO and the Regeneration Time Option set to DELAY REGEN or DELAY IMMEDIATE The actual reserve capacity is compared to the gallons capacity remaining immediately prior to the preset regeneration
7. Day Override using A or Y buttons e number of days between regeneration 1 to 28 or e OFF See Setting Options Table for more detail on setup Press NEXT to go to step 4I Press REGEN to return to previous step STEP 41 Next Regeneration Time hour Set the hour of day for regeneration using A or Y buttons AM PM toggles after 12 The default time is 2 00 AM This display will show REGEN IMMEDIATE ON ZERO GAL if IMMEDIATE is selected in Set Regeneration Time Option in OEM Softener System Setup Step 9S Press NEXT to go to Step 51 Press REGEN to return to previous step When Step 6CS is set to a value of two to four additional regeneration time settings will be viewed These displays are used to set additional times of day where a regeneration cycle may be initiated by the control as needed When this feature is active a number 1 4 will be added to the upper right corner of this display to indicate which of the additional regeneration time settings is currently being viewed STEP 5I Next Regeneration Time minutes Set the minutes of day for regeneration using A or Y buttons This display will not be shown if IMMEDIATE is selected in Set Regeneration Time Option in OEM Softener System Setup Step 9S Press NEXT to go to Step 61 Press REGEN to return to previous step When this feature is active a number 1 4 will be added to the upper right corner of this display to indicate which of the additional rege
8. Step 7S and before Step 8S if the system is set up as a prefill upflow softener The following options can be selected e NORMAL FILL System always prefills with the salt level selected e PROPORTIONAL FILL If proportional brining is selected the actual salt fill time will be calculated by dividing the actual volume of treated water used by the full volumetric capacity then multiplying this value by the maximum salt fill time Croc ra x Press NEXT to go to the next step Press REGEN to return to the previous step Backlight Control As an energy saving feature the control will automatically turn off the display illumination after 5 minutes of keypad inactivity or minute after the last use of treated water Any further keypad activity or water use will re illuminate the display for or 5 minutes The Energy Saver feature default is ON The Master Illumination button is located in the lower right hand portion of the board The purpose of the button is to manage the keypad backlights and the Energy Saver feature When the keypad backlights are OFF pressing and holding this button for about 5 seconds will turn the lights ON and turn the energy saver feature OFF which will be indicated with a display ENERGY SAVER OFF If the button is not held until the Energy Saver Off display is shown the backlights for the display and the keypad will both go OFF after 5 minutes of no keypad activity The keypad backlights will rem
9. time A regeneration will occur if the actual reserve capacity is less than the gallons capacity remaining The actual reserve capacity is calculated by using the estimated reserve capacity and adjusting it up or down for actual usage The estimated reserve capacity for a given day of the week is the maximum value stored for the last three non trivial water usages i e more than 20 gallons day in seven day intervals See Installer Display Settings OEM Softener System Setup and OEM Filter System Setup for explanations of Day Override and Gallon Capacity Days to REGEN and Gallon Capacity can not both be set to OFF at the same time Page 6 PR Manual To lock out access to diagnostic and valve history displays and modifications to settings except hardness day override time of regeneration and time of day by anyone but the manufacturer press Y NEXT A and CLOCK in sequence after settings are made To unlock so other displays can be viewed and changes can be made press W NEXT A and CLOCK in sequence When in operation normal user displays such as time of day volume remaining before regeneration present flow rate or days remaining before regeneration are shown When stepping through a procedure if no buttons are pressed within five minutes the display returns to a normal user display Any changes made prior to the five minute time out are incorporated To quickly exit OEM Softener Setup OEM Filter Setup OEM Configura
10. 1S Press NEXT and Y simultaneously for 3 seconds and release If screen in Step 2S does not ES Gn SY appear in 5 seconds the lock on the valve is activated To unlock press W NEXT A and CLOCK in sequence then press NEXT and Y simultaneously for 3 seconds and release w Step 2S Choose the SOFTENING program desired see table using the Y or A button Press NEXT 7 to go to Step 3S Press REGEN to exit OEM Softener System Setup Step 3S Select the time for the first cycle using the Y or A button Press NEXT to go to Step 4S Press REGEN to return to previous step BACKWASH TIME DSTTIVIITITI SET 8 00 MIN PEPV Step 4S Select the time for the second cycle using the Y or A button Press NEXT to go to Step 5S Press REGEN to return to previous step DRAW TIME BT SOEQ Step 5S Select time for the third cycle using the W or A button Press NEXT to go to Step 6S Press REGEN to return to previous step BACKWASH TIME 777177 E S09 Step 6S Select the time for the fourth cycle using the V or A button Press NEXT to go to Step 7S Press REGEN to return to previous step RINSE TIME PR Manual Page 11 Step 7S Select the LBS or MIN for the fifth cycle using the Y or A button When 2 0 is selected in FILL GRAINS OF CAPACITY RESERVE CALCULATOR SET Step 2CS FILL is on minutes WS2 valves are shipp
11. Water Specialist PR Control Valve Programming and Cover Drawing Manual d N Page 2 PR Manual PR Manual Page 3 Table of Contents PR Front Cover and Drive ASsemDly ics 3 uss asistipssesscssanesvasesesncesaces ip costcessnscnsadeusesoapceanesoanesdeaus sues seeds sonidos pare 4 OEM General Programming Instructions eiii ic een nn eben 5 OEM Configuration Set p uinn ee alien oia 7 OEM Softener System Setup u nen ae nennen 10 setting Options Table ee ae enon vashsbabestauevenseipesesdabecbancsvsbGusbsnansbeanesbend 13 OEM Ellter System sep ae ee a He 14 Installer Display Settings eine e Ea E OE OE ne ph ernten oabeasnsiveassdedtoane 16 User Display S ttingS g s ksssasstsanes ias tas etsus dvuks e cid 17 EA soeaucsbaaucpasdepbnednaesspapeosasnssusebpneeatcsciesstanlssbhuedisespuscvondlessbenvetoapascnen reas 20 Valve SO Vii Reken 21 Page 4 PR Manual PR Front Cover and Drive Assembly Drawing No Order No Description Quantity 1 V3692 01PW WS1LP FRONT COVER ASY PURITAN HSB Y BLK 1 2 V3107 01 WS1 MOTOR 1 3 V3106 01 WS1 DRIVE BRACKET amp SPRING CLIP 1 4 V3757PR BOARD WS1THRU2L 2 PR PC BOARD REPLACE 1 5 V3110 WS1 DRIVE GEAR 12X36 3 6 V3109 WS1 DRIVE GEAR COVER 1 V3186 WS1 AC ADAPTER 110V 12V V3186EU WS1 AC ADAPTER 220 240V 12V EU
12. a preset duration of time REGEN GAL Relay activates every set number of gallons have been used while in service or during regeneration for a preset duration of time OFF Deactivates this output Press NEXT to go to Step 13S Press REGEN to return to previous step Page 12 SCHEDULED SERVICE PR Manual Step 13S Set scheduled service alarm using the A or Y Available options are OFF TIME ON GAL or BOTH Selecting OFF disables this feature If OFF is selected press NEXT to exit OEM System Setup If TIME ON GAL or BOTH is selected press NEXT to select the TIME and or ON GAL values See Steps 14S and or 15S Press REGEN to return to the previous step Step 14S Status display Time remaining until Service Alarm generation Only appears if TIME or BOTH is set in Step 13S To change duration time press and hold the A and Y buttons for about 3 seconds until SET appears and the number flashes Use A or Y to select the new value Press NEXT to either exit OEM Softener System Setup or go to Step 15S if BOTH was selected in Step 13S Press REGEN to return to the previous step Step 15S Status display Volume remaining until Service Alarm generation Only appears if GAL or BOTH is set in Step 13S To change the volume between service calls press and hold the A and Y buttons for about 3 seconds until SET appears and the number flashes Use A or to select the new value Press NEXT to exit OEM So
13. ain OFF until either the Master Illumination or any keypad button is pressed to turn them back ON PR Manual Page 7 OEM Configuration Setup Step 1CS Press NEXT and Y simultaneously for 3 seconds and release Then press NEXT and Y simultaneously for 3 seconds and release If screen in Step 2CS does not appear in 5 seconds the lock on the valve is activated To unlock press W NEXT A and CLOCK in sequence then press NEXT and Y simultaneously for 3 seconds and release Then press NEXT and Y simultaneously for 3 seconds and release Step 2CS Use the A or Y to select 1 0 for 1 valve 1 25 for 1 25 valve 1 5 for 1 5 valve 2 0L for VALVE TYPE 2L valve or 2 0 for 2 valve When 2 0L or 2 0 is selected an additional screen will appear It is used to a 1 IN select which size flow meter is to be used with the valve 1 5 2 0 or Variable Meter Calibration When the Variable Meter feature 1s selected enter the desired number of pulses per gallon that the flow meter will generate Press NEXT to go to Step 3CS Press REGEN to exit OEM cycle sequence METER SIZE Step 3CS When 2 0L or 2 0 are selected an additional screen will appear It VARIABLE METER YT NU SET is used to select which size flow meter is to be used with the valve 1 5 or 2 0 SET l PPG 1 Variable meter pulses of 0 1 150 0 PPG can also be selected a A Press NEXT to go to Step 4CS Press REGEN to return to previous step T Y Note When usin
14. alue Press NEXT to exit OEM Filter System Setup Press REGEN to return to the previous step Page 16 ser eep w E WATER HARDNESS VT DIV S STEPS DAYS BETWEEN REGEN vai PUTA sera REGEN TIME HOUR AUD so SET STEPS REGEN TIME MIN MOSIT PIANOS PEPV PR Manual Installer Display Settings STEP 11 Press NEXT and A simultaneously for 3 seconds STEP 21 Hardness Set the amount of hardness in grains of hardness as calcium carbonate per gallon using the A or Y buttons The default is 20 with value ranges from 1 to 150 in 1 grain increments Note The grains per gallon can be increased if soluble iron needs to be reduced This display will not show if FILTER is selected in Step 2F or if AUTO is not selected in Set Volume Capacity in OEM Softener System Setup Press NEXT to go to step 3I Press REGEN to exit Installer Display Settings STEP 3I Day Override When volume capacity is set to OFF sets the number of days between regenerations When volume capacity is set to AUTO or to a number sets the maximum number of days between regenerations If value set to OFF regeneration initiation is based solely on volume used If value is set as a number allowable range from 1 to 28 a regeneration initiation will be called for on that day even if sufficient volume of water were not used to call for a regeneration Set
15. as a softener or filter Table 1 Regeneration Cycles Softening WS1PR only WSIPR only Upflow Regenerant Upflow Regenerant Refill After Rinse Prefill Downflow Regenerant Downflow Regenerant Refill After Rinse Prefill 1 Cycle Backwash 1 Cycle Fill 1 Cycle UP Brine 1 Cycle Fill 2 Cycle dn Brine 2 Cycle Softening 2 Cycle Backwash 2 Cycle Softening 3 Cycle Backwash 3 Cycle Backwash 3 Cycle Rinse 3 Cycle UP Brine 4 Cycle Rinse 4 Cycle dn Brine 4 Cycle Fill 4 Cycle Backwash 5 Cycle Fill 5 Cycle Rinse 5 Cycle Rinse Table 2 Regeneration Cycles Filtering Downflow Regenerant Refill After Rinse 1 Cycle Backwash 1 Cycle Backwash 2 Cycle dn Regenerant Draw 2 1Cycle Rinse 3 Cycle Backwash 4 Cycle Rinse 5 Cycle Fill The control valve with a water meter can be set for Demand Initiated Regeneration DIR only Time Clock operation only or DIR and Time Clock which ever comes first depending upon what settings are selected for Day Override and Gallon Capacity See Table 3 If a control valve does not contain a meter the valve can only act as a time clock and day override should be set to any number and gallon capacity should be set to off Table 3 DIR Time Clock Options Softener Gall u in ff Reserve Capacity Automatically calculated If desired enter a value less than estimated capacity If desired enter a value less than Any Number estimated capacity For
16. ase If screen in Step 2F does not appear in 5 seconds the lock on the valve is activated To unlock press Y NEXT A and CLOCK in AS DA sequence then press NEXT and Y simultaneously for 3 seconds and release w Step 2F Choose the FILTERING program desired using the Y or A buttons Press NEXT to go to Step 3F Press REGEN to exit OEM Filter System Setup FILTERING BW RINSE sr TIPE SOQ Step 3F Select the time for the first cycle which in this example is BACKWASH using theW or A button Press NEXT to go to Step 4F Press REGEN to return to previous step BACKWASH TIME ONO SET Bill es Step 4F Select the time for the second cycle which in this example is RINSE using the Y or A button Press NEXT to go to Step 5F Press REGEN to return to previous step un SET 4 l MIN gt 09 Step 5F Set Volume Capacity using the Y or A button If value is set to e OFF regeneration will be based solely on the day override set see Installer Display Settings Step 31 or e As a number regeneration initiation will be based off the value specified See Setting Options Table for more detail Press NEXT to go to Step 6F Press REGEN to return to previous step GALLONS CAPACITY Step 6F Set Regeneration Time Options using the Y or A button If value is set to e DELAYED REGEN means regeneration will occur at the preset time e IMMEDIATE means regeneration wil
17. been treated since the last regeneration This display will equal zero if a water meter is not installed Press NEXT to go to Step 4D Press REGEN to return to previous step STEP 4D Reserve History Volume used for last 7 days If the valve is set up as a softener a meter is installed and Set Volume Capacity is set to Auto this display shows O day for today and the reserve capacity Pressing the A button will show day 1 which would be yesterday and the reserve capacity used Pressing the A button again will show day 2 the day before yesterday and the reserve capacity Keep pressing the A button to show the capacity for days 3 4 5 and 6 The Y button can be pressed to move backwards in the day series This screen is not displayed if filter time clock meter immediate volume override or alternator regeneration is selected Press NEXT at any time to go to Step 5D Press REGEN to return to previous step STEP 5D Volume 63 day usage history This display shows day 0 for today day 1 for yesterday etc and the volume of water treated that day Press the A button to show the volume of water treated for the last 63 days If a regeneration occured on the day the letter R will also be displayed This display will show dashes if a water meter is not installed Press NEXT at any time to go to Step 6D Press REGEN to return to previous step STEP 6D Flow rate maximum last seven days Use the A or Y to display the maximum flow rat
18. city falls below the reserve IMMEDIATE capacity at the next Regen Set Time or regeneration occurs after 10 minutes of no water usage when volume capacity reaches 0 Reserve capacity automatically estimated DELAY Any Regeneration occurs at the next Regen Set Time when volume capacity AUTO falls below the reserve capacity or the specified number of days between ay FF E Reserve capacity not automatically estimated Regeneration occurs immediately when volume capacity reaches 0 AUTO IMMEDIATE OFF Time of regeneration will not be allowed to be set because regeneration will always occur when volume capacity reaches 0 E FF IMMEDIATE number i regenerations is reached or regeneration occurs after 10 minutes of no water usage when volume capacity reaches 0 Reserve capacity not automatically estimated Any DELAY Any Regeneration occurs at the next Regen Set Time when the specified number IMMEDIATE number number of days between regenerations is reached or regeneration occurs after 10 minutes of no water usage when volume capacity reaches 0 gt Reserve capacity estimate is based on history of water usage Page 14 PR Manual OEM Filter System Setup Filtering Cycle Programs BW _ DrawDN__ BW__ Rinse Fil X FILTERNGBWRINSE x x 1 120 or OFF i Bee Draw DN Minutes 1 1800r0OFF 60 Fil valve Minutes 01 9900rOFF 60 Step IF Press NEXT and Y simultaneously for 3 seconds and rele
19. d the REGEN button for three seconds The system will begin to regenerate immediately The request cannot be cancelled Note For softeners if brine tank does not contain salt fill with salt and wait at least two hours before regenerating Page 18 Set Time of Day PR Manual The user can also set the time of day Time of day should only need to be set if the battery has been depleted because of extended power outages or when daylight saving time begins or ends If an extended power outage occurs the time of day will flash on and off which indicates the time of day should be reset The non rechargeable battery should also be replaced Poo TIME HOUR Br 0PYQ TIME MINUTES SET OPQ STEP 1U Press CLOCK STEP 2U Current Time hour Set the hour of the day using Y or A buttons AM PM toggles after 12 Press NEXT to go to Step 3U STEP 3U Current Time minutes Set the minutes of the day using Y or A buttons Press NEXT to exit Set Time of Day Press REGEN to return to previous step RETURN TO NORMAL MODE STAND BY REGEN PENDING will be displayed in Alternator Systems whenever a unit is waiting to initiate the first cycle step of regeneration STAND BY will be displayed in Alternator Systems when a valve is in Standby state DELAYED RINSE FILL PENDING will be displayed whenever a zero capacity tank has transferred to an off line state and is currently waiting to initiate the second portio
20. e in gallons per minute that occurred in each of the last seven days This display will equal zero if a water meter is not installed Press NEXT to exit Diagnostics Press REGEN to return to previous step RETURN TO NORMAL MODE When desired all information in Diagnostics the Program and User Settings may be reset to defaults when the valve is installed in a new location To reset press NEXT and Y buttons simultaneously to go to the Softening Filtering Type screen Press A and Y simultaneously to reset Diagnostics to zero and the Program and User Settings to defaults The time will be reset to 12 00 P M PR Manual A SOS BODA TOTAL DAYS 970 A og TOTAL REGENS 235 A org TOTAL GALLONS 75 x K A sep A A ERROR LOG 102 0PYQ w RETURN TO NORMAL MODE Page 21 Valve History STEP 1VH Press A and Y simultaneously for three seconds and release Then press A and Y simultaneously and release If screen in step 2VH does not appear in 5 seconds the lock on the valve is activated To unlock press V NEXT A and CLOCK in sequence then press A and Y simultaneously for 3 seconds and release Then press A and Y simultaneously and release STEP 2VH Days total since start up This display shows the total days since startup Press NEXT to go to Step 3VH Press REGEN to return to previous step STEP 3VH Regenerations total number si
21. ed from the factory with a refill flow control of 2 2 gpm 8 3 Ipm Press NEXT to go to Step 8S Press REGEN to return to previous step Step 8S Set Grains Capacity using the A or Y button The ion exchange capacity is in grains of hardness as calcium carbonate for the system based on the pounds of salt that will be used Calculate the pounds of salt using the fill time previously selected Grains capacity is affected by the fill time The grains capacity for the selected fill time should be confirmed by OEM testing The capacity and hardness levels entered are used to automatically calculate reserve capacity when gallon capacity is set to AUTO Press NEXT to go to Step 9S Press REGEN to return to previous step Step 9S Set Volume Capacity using the A or Y button If value is set to e AUTO capacity will be automatically calculated and reserve capacity will be automatically estimated e OFF regeneration will be based solely on the day override set see Installer Display Settings Step 31 or e GALS BETWEEN REGEN regeneration will be based off the value specified If OFF or a number is used hardness display will not be allowed to be set in Installer Display Settings Step 21 See Setting Options Table for more detail Press NEXT to go to Step 10S Press REGEN to return to previous step Step 10S Set Regeneration Time Options using the A or Y button If value is set to e DELAYED REGEN means regeneration will occur a
22. eration Select Separate Source Enabled for control operation For separate source operation the three OP wire connector is not used Selection reguires that a connection to a Clack Motorized Alternator Valve MAV is made to the two pin connector labeled SEPERATE SOURCE MAV MTR located on the printed circuit board The C port of the MAV must be connected to the valve inlet and the A port BET MATARI PP connected to the separate source used during regeneration The B port must be connected to the feed water supply When set to Separate Source Enabled the MAV will be driven closed before the first regeneration cycle and be driven open after the last regeneration cycle NOTE If the control valve enters into an error state during regeneration mode the MAV will remain in its current state until the error is corrected and reset Press NEXT to go to Step 5CS Press REGEN to return to previous step Step 5CS Set Aux MAV Output to operate in one of three modes TIME Output is activated at a set time after the start of regeneration for a specified length of time AUX MAV OFF SEP SOURCE Allows Auxiliary MAV to switch positions before the start of regeneration and then switch back at the end of regeneration SEN M I D E OFF Deactivates this output Press NEXT to go to Step 6CS Press REGEN to return to previous step Step 6CS Allows selection of an outside signal to control the initiation of a regeneration Selection only matters
23. es days in diagnostics which results in time clock only twin regeneration initiation e Twin alternating systems can be programmed for a delayed regeneration time The system will allow an immediate transfer of the MAV to switch tanks and place a fully regenerated unit in service once a unit becomes exhausted The exhausted unit will then be placed into Stand by Mode and allowed to have a delayed regeneration at the pre set time PR Manual Page 9 NOTE If the control valve is in an error state during regeneration mode the MAV will close the B port and keep open the A port until the error is corrected and reset WS1 WS1 25 WS1 5 For Clack Corporation alternator systems using the WS1 WS1 25 WS1 5 and WS2L valves WS2L Valves WS2 Valve there will be an option to delay the last two steps of regeneration Rinse and Fill until just tes ALTERNATOR MAV ALTERNATOR MAV prior to a return to Service Upon completion of the initial regeneration steps the valve will SOSA SAA enter Standby If the Delayed Rinse and Fill is not set to ON the regeneration will proceed SET SET normally without any delays between cycles For Clack Corporation alternator systems using the WS2 valve when NEXT is pressed after selecting ALTA or ALTb a display will allow the user to set the amount of pre service rinse time for the stand by tank just prior to returning to service DELAYED RINSE FILL SET Configuring the Control Valve for Separate Source Op
24. ftener System Setup Press REGEN to return to the previous step RETURN TO NORMAL MODE PR Manual Page 13 Setting Options Table Filters should only use shaded options Volume Regeneration D Result Capacity Time Option Override DELAYED Reserve capacity automatically estimated AUTO REGEN O Regeneration occurs when volume capacity falls below the reserve capacity at the next Regen Set Time Reserve capacity automatically estimated AUTO DELAYED Any Regeneration occurs at the next Regen Set Time when volume capacity REGEN number falls below the reserve capacity or the specified number of days between regenerations is reached A DELAYED Reserve capacity not automatically estimated O Regeneration occurs at the next Regen Set Time when volume number REGEN capacity reaches 0 Reserve capacity not automatically estimated DELAYED A OFF 2y Regeneration occurs at the next Regen Set Time when the specified REGEN number number of days between regenerations is reached F Reserve capacity not automatically estimated siles eee number REGEN number In P y regenerations is reached F Reserve capacity not automatically estimated Any IMMEDIATE O Regeneration occurs immediately when volume capacity reaches 0 l number Time of regeneration will not be allowed to be set because regeneration will always occur when volume capacity reaches 0 Reserve capacity automatically estimated AUTO DELAY O Regeneration occurs when volume capa
25. g the WS2 valve if 2 0L is set instead of 2 0 when the valve is in regeneration and the piston drives to the DRAW cycle the piston will stall and generate a 102 error code Clear the error code by pressing NEXT and REGEN buttons simultaneously until the valve resets then re program valve to proper valve type setting When using the WS2 control valve the circuit board software must have valve selection choices of 2 0 and 2 0L The WS2 valve must be set for the 2 0 valve type during programming If the software version does not have both the 2 0 and 2 0L selections consult your equipment supplier for a replacement circuit board When using the WS2L valve with older version software that does not have both 2 0 and 2 0L selection choices the valve must be set to 2 0 during programming If a WS2L valve is being used with newer version software that has both 2 0 and 2 0L selection choices the valve must be set to 2 0L during programming Page 8 PR Manual Step 4CS Allows selection of one of the following using the A or W buttons ALTERNATOR MAY e the Control Valve to have no hard water bypass e the Control Valve to act as an alternator or the Control Valve to have a separate source during the regeneration cycle Select OFF when neither of these features are used POPS Only use Clack No Hard Water Bypass Valves or Clack Motorized Alternating Valves MAV with these selections Clack No Hard Water Bypass Valves 1
26. l occur immediately when the volume capacity reaches 0 zero or e DELAY IMMEDIATE means regeneration will occur at one of the following ED 3 S the preset time when the volume capacity falls below the reserve or the specified number of days between regenerations is reached whichever comes first or immediately after 10 minutes of no water usage when the volume capacity reaches 0 zero See Setting Options Table for more detail Press NEXT to go to Step 7F Press REGEN to return to previous step PR Manual RELAY 1 OFF SET SOO Duy RELAY 2 OFF SET SOO SERVICE ALA RM Werenee 0000000 SOTO SCHEDULED SERVICE I SOO SCHEDULED SERVICE SOO Page 15 Step 7F Set Relay 1 MODE operation using the Y or A button The choices are TIME Relay activates at a set time after the start of a regeneration and then deactivates after a set period of time GALLONS Relay activates after a set number of gallons have been used while in service for a preset duration of time REGEN GAL Relay activates every set number of gallons have been used while in service or during regeneration for a preset duration of time OFF Deactivates this output Press NEXT to go to Step 8F Press REGEN to return to previous step Step 8F Set Relay 2 MODE operation using the Y or A button The choices are TIME Relay activates at a set time after the start of a regeneration and then deactivates afte
27. n of a regeneration cycle Viewed only when Delayed Rinse and Fill is set to ON PR Manual Page 19 Power Loss If the power goes out the system will keep time until the battery is depleted If an extended power outage occurs the time of day will flash on and off which indicates the time of day should be reset and the non rechargeable battery replaced The system will remember the rest Error Message If the word ERROR and a number are displayed contact the OEM for help This indicates that the valve was not able to function properly If the number and banner text display has been edited the two displays will alternate VALVE HOMING ERROR VALVE HOMING CALL XXXX FOR SERV ERROR 59 3390003 Page 20 Ze Sea OP SINCE LAST REGEN 94 sa A POG 0PYQ USAGE HISTORY R L 12300 OPQ oard 9 gor FEPO DAY PR Manual Diagnostics STEP 1D Press A and Y simultaneously for three seconds If screen in step 2D does not appear in 5 seconds the lock on the valve is activated To unlock press NEXT A and CLOCK in sequence then press A and Y simultaneously for 3 seconds STEP 2D Days since last regeneration This display shows the days since the last regeneration occurred Press NEXT to go to Step 3D Press REGEN to exit Diagnostics STEP 3D Volume since last regeneration This display shows the volume of water that has
28. nce start up This display shows the total number of regenerations that have occurred since startup Press NEXT to go to Step 4VH Press REGEN to return to previous step STEP 4VH Volume total used since start up This display shows the total gallons treated since startup This display will equal zero if a water meter is not installed Press NEXT to go to Step 5VH Press REGEN to return to previous step STEP 5VH Flow rate Total Peak Flow This display shows the maximum flow rate since startup Press NEXT to go to Step 6VH Press REGEN to return to the previous step STEP 6VH Total Errors This displays the total number of errors detected since startup Press NEXT to go to Step 7VH Press REGEN to return to the previous step STEP 7VH Log of the last 10 Error Codes generated by the control Press the A or Y button to view each error recorded Press NEXT to exit Valve History Press REGEN to return to the previous step Values in steps 2VH through 7VH cannot be reset Page 22 PR Manual PR Manual Page 23 Page 24 PR Manual Form No V3435PR 4 15 2011
29. neration time settings is currently being viewed RETURN TO NORMAL MODE Contact Screens From Step 4I press and hold both the CLOCK and A button to change phone number and banner text 55 5555555 PEPV 7 an ss 5555555 PEPV Phone Number Set phone number using the A or Y arrow Press NEXT to forward to the next digit Press REGEN to return to previous digit Banner Text Set the banner text up to a maximum of 44 characters Use the A or Y to select letters of the alphabet or a number in the banner text Press NEXT to forward to the next character or to exit the Installer Display Settings PR Manual Page 17 User Display Settings General Operation When the system is operating one of six displays may be shown REMAINING CAPAGITY OF DAYS TO REGEN Pressing NEXT will alternate between the displays One of the 4 650 GAL displays is always the current time of day The second display is one of the following days remaining or volume remaining ZN A Days remaining is the number of days left before the system goes DOES OGU through a regeneration cycle Capacity remaining is the gallons that will be treated before the system goes through a regeneration y cycle Pressing the W button while in the Capacity Remaining or Dana TIME OFT DAY Days Remaining displays will decrease the capacity remaining in we is being treated R 6 3 5 BM I 10 gallon increments or the Days Remaining in 1 day increments
30. r a set period of time GALLONS Relay activates after a set number of gallons have been used while in service for a preset duration of time REGEN GAL Relay activates every set number of gallons have been used while in service or during regeneration for a preset duration of time OFF Deactivates this output Press NEXT to go to Step 9F Press REGEN to return to previous step Step 9F Set scheduled service alarm using the W or A Available options are OFF TIME ON GAL or BOTH Selecting OFF disables this feature If OFF is selected press NEXT to exit OEM System Setup If TIME ON GAL or BOTH is selected press NEXT to select the TIME and or ON GAL values See Steps 10F and or 11F Press REGEN to return to the previous step Step 10F Status display Time remaining until Service Alarm generation Only appears if TIME or BOTH are set in Step 9F To change duration time press and hold the W and A buttons for about 3 seconds until SET appears and the number flashes Use W or A to select the new value Press NEXT to either exit OEM Filter System Setup or go to Step 11F if BOTH was selected in Step 9F Press REGEN to return to the previous step Step 11F Status display Volume remaining until Service Alarm generation Only appears if GAL or BOTH are set in Step 9F To change the volume between service calls press and hold the Wand A buttons for about 3 seconds until SET appears and the number flashes Use W or A to select the new v
31. regeneration of a unit can be prevented upon switch closure If the unit depletes the capacity down to zero it will not be allowed to switch tanks to regenerate until the switch is open Note For WS1 WS2L control valves programmed for twin alternating the Delayed Rinse and Fill feature can be set in conjunction with the HOLD REG if desired Press NEXT to go to Step 7CS Press REGEN to return to previous step MULTI REGEN TIMES Step 7CS Multiple Regenerations Set the number of regenerations that will occur on the day of regeneration When this feature is active two to four regeneration cycle times are possible on the scheduled multi regeneration SET N M P E E DEF day Multi regeneration days are determined by the number of days set in the Day Between Regen Setting Step Ya 31 OFF will cancel this feature and limit the amount of Regen Times to one Display is only viewed if Step 9S or 5F is set to oFF PEP Press NEXT exit Configuration Setup Press REGEN to return to previous step Page 10 PR Manual OEM Softener System Setup SOFTENING UP PRE 1 Valve Onl 1 1200rOFF_ 8 Rinse 1 I20orOFE 4 1 180orOFF 60 0 1 200 0or OFF 95 g 240 Backwash 4 9 5 1 480 or OFF 240 Fill 2 valve Minutes 01 990orOFF 60 If a 1 upflow control valve is programmed for prefill the proportional brining display will appear after the grains capacity display Step 7S Step
32. t the preset time e IMMEDIATE means regeneration will occur immediately when the volume capacity reaches 0 zero or e DELAY IMMEDIATE means regeneration will occur at one of the following the preset time when the volume capacity falls below the reserve or the specified number of days between regenerations is reached whichever comes first or immediately after 10 minutes of no water usage when the volume capacity reaches 0 zero See Setting Options Table for more detail This screen is not viewed if Step 8S is set to OFF Press NEXT to go to Step 11S Press REGEN to return to previous step Step 11S Set Relay 1 MODE operation using the A or Y button The choices are TIME Relay activates at a set time after the start of a regeneration and then deactivates after a set period of time GALLONS Relay activates after a set number of gallons have been used while in service for a preset duration of time REGEN GAL Relay activates every set number of gallons have been used while in service or during regeneration for a preset duration of time OFF Deactivates this output Press NEXT to go to Step 12S Press REGEN to return to previous step Step 12S Set Relay 2 MODE operation using the A or Y button The choices are TIME Relay activates at a set time after the start of a regeneration and then deactivates after a set period of time GALLONS Relay activates after a set number of gallons have been used while in service for
33. ter when the system is y 6 36 MIN regenerating untreated water will be used 2 I DISPLAYS When the system begins to regenerate the display will change to include information about the step of BEING VIEWED the regeneration process and the time remaining for that step to be completed The current cycle display REGEN COMPLETED IN will alternate with the regen time remaining screen The system runs through the steps automatically 036 VIS l and will reset itself to provide treated water when the regeneration has been completed Manual Regeneration Sometimes there is a need to regenerate the system sooner than when the system calls for it usually referred to as manual regeneration There may be a period of heavy water usage because of guests or a heavy laundry day To initiate a manual regeneration at the preset delayed regeneration time when the regeneration time option is set to DELAYED REGEN or DELAY IMMEDIATE press and release REGEN The words REGEN TODAY will periodically be shown on the display to indicate that the system will regenerate at the preset delayed regeneration time If you pressed the REGEN button in error pressing the button again will cancel the request Note If the regeneration time option is set to IMMEDIATE there is no set delayed regeneration time so REGEN TODAY will not activate if REGEN button is pressed To initiate a manual regeneration immediately press and hol
34. tion Setup Installer Display Settings Diagnostics or Valve History press CLOCK Any changes made prior to the exit are incorporated To clear the Service Call reminder press the A and Y buttons simultaneously while CALL is displayed When desired all information in Diagnostics the Program and User Settings may be reset to defaults when the valve is installed in a new location To reset press NEXT and Y buttons simultaneously to go to the Softening Filtering Type screen Press A and Y simultaneously to reset Diagnostics to zero and the Program and User Settings to defaults The time will be reset to 12 00 P M Sometimes it is desirable to have the valve initiate and complete two regenerations within 24 hours and then return to the preset regeneration procedure It is possible to do a double regeneration if the control valve is set to DELAYED REGEN or DELAY IMMEDIATE in OEM Softener System Setup or OEM Filter System Setup To do a double regeneration 1 Press the REGEN button once REGEN TODAY will flash on the display 2 Press and hold the REGEN button for three seconds until the valve regeneration initiates Once the valve has completed the immediate regeneration the valve will regenerate one more time at the preset regeneration time Proportional Brining If the system is set up as a prefill 1 upflow softener the control valve can also be set to normal or proportional brining This step will appear after
Download Pdf Manuals
Related Search
Related Contents
GE ADW1000 User's Manual JDS RM3750B Dual Source Backreflection Meter JDS RM3000A Univex YB9290 User's Manual Handbuch USB Host Human Interface Devices Class Driver (HHID) Manual Español SM Installation - Bradley Corporation USER MANUAL Panasonic EY6903 Cordless Drill User Manual Copyright © All rights reserved.