Home
Manual - DiaMedical USA
Contents
1. DPI time axis 250 DPI time axis at 50 mm sec Battery Capacity 40 auto ECGs and 40 copies on a single charge or 40 minutes continuous rhythm recording Recharge Typically seven hours to 90 capacity and 16 hours to full capacity Storage option Capacity 30 ECGs PageWriter 200 and 300pi Type 2 MB of non removable flash memory Transmission option Serial Port 1 RS232 Modes Direct Connect Modem PageWriter 200 and 300pi Modem Command Interfaces Data Hayes standard AT command set Fax EIA TIA 578 Service Class 1 Standard Accessories Supplied Patient cable Power cord 200 sheets of Z fold paper Starter kit of adapter clips and electrodes U S only User s guide Training video Interpretive Physician s Guide PageWriter 300pi Predictive Instrument Physician s Guide PageWriter 300pi only Quick Reference Guide PageWriter 300pi only Accessories Available M1705B Mobile cart for M177xA cardiographs M2463A Carrying case for M177xA cardiographs M2460A Replacement battery for M177xA cardiographs M2461A Replacement patient cable AHA M2462A Replacement patient cable IEC M1706B Data communications package M1706B opt ABA Data communications package modem Modem cable Modem TraceMaster cabling Direct Connect cable M2482A 200 sheets Z fold thermal paper without header 8 5 x 11 M2483A 200 sheets Z fold thermal paper metric M2485A 200 sheets Z fold th
2. HP ECG measurement software is standard in the PageWriter 200 and 300pi cardiographs Measurements of 12 simultaneously acquired leads result in ECG morphology and rhythm parameters A short table is printed with the HR PR QRSD QT QTc and the axis val ues P QRS and T If desired an extended measurements table may also be generated HEWLETT PACKARD L Cardiography ECG Interpretation The PageWriter 300pi contains HP s clinically proven Adult and Pediatric Analysis Programs With these pro grams pediatric ECGs can be analyzed for patients from one hour to 15 years old For both peds and adults original reports and copies may be configured to include or exclude ECG measure ments interpretive statements and rea sons Predictive Instruments The PageWriter 300pi provides Acute Cardiac Ischemia Time Insensitive Predictive Instrument ACI TIPD and Thrombolytic Predictive Instrument TPI applications ACI TIPI calculates a predicted probability of acute cardiac ischemia TPI predicts the probability of patient outcome for short term mor tality long term mortality cardiac arrest and risk associated with throm bolytic therapy ECG Storage and Transmission M1770A M1771A Optional Using non removable flash memory the PageWriter 200 and 300pi cardio graphs can store up to 30 ECGs at a time ECGs can be faxed directly via modem from the cardiograph or transmitted to an HP compatible
3. 35 8154 Korea Hewlett Packard Korea 82 2 769 0114 Singapore Southeast Asia Hewlett Packard Singapore Sales Pte Ltd 65 275 3888 Taiwan Hewlett Packard Taiwan Ltd 886 2 712 0404 In Europe please call your local HP sales office or representative Marketing Center Europe Hewlett Packard GmbH Herrenberger Str 140 71034 Boeblingen Germany Fax 49 7031 14 4096 Medical Distribution Europe Middle East Africa Geneva Switzerland 41 22 780 4111 Austria Central Europe Austria Office 43 1 25000 6273 Belgium Luxembourg Belgium Office 32 2778 31 11 Czech Republic 42 2 613 07 427 Finland 358 0 887 21 France 33 1 69 29 43 43 Italy 39 2 92 121 Netherlands 31 20 547 63 38 Poland 48 22 608 7700 Russia 7 095 916 9811 x3870 3873 South Africa 27 11 806 10 00 Spain 34 93 582 13 00 Sweden 46 8 444 20 00 Switzerland 41 1 735 71 11 German Swiss 41 22 780 41 11 Suisse Romande United Kingdom 44 1344 369 269 For more information about HP s cardiology products visit our Web site www hp com go heart Visit our educational web site for informa tion on sudden cardiac arrest www chainof survival com HP in Healthcare Helping You Make A Difference Caution In the U S federal law restricts this device to sale on or by the order of a physician The information contained in this document is sub jec
4. ECG management system for review and editing Specifications Unless otherwise noted the following specifications apply to PageWriter 100 200 and 300pi cardiographs Regulatory Standards IEC 601 1 IEC 601 2 25 Basic Controls ECG Controls On Standby Auto Manual Chart Speed Size Copy Filter Page Advance ECG Format Selections Manual Lead Group V Leads PageWriter 100 Rhythm Lead ID PageWriter 200 and 300pi ECG Format Selections Auto 3x4 IR rhythm lead fixed as Lead II Manual with 3 leads PageWriter 100 ECG Format Selections Auto with 0 1 or 3 rhythm leads Manual with 3 6 or 12 leads PageWriter 200 and 300pi Keyboard with full alphanumeric capability PageWriter 200 and 300pi PageWriter 100 has LED indicators for constant status display no alphanumeric keyboard Patient Safety Patient Isolation IEC type CF isolated patient connection Defibrillator Protection Protected against damage from 400 joule defibrillation discharges when using HP specified patient cable Instrument Test Self test performed each time cardiograph is turned on Extended tests for main instrument printing and display functions Displays fault message to operator PageWriter 200 and 300pi Power and Environment Line Power 100 120 or 220 240 V ac selectable 50 60 Hz 50 VA Environmental Operating Conditions 10 to 40 C 50 to 104 F 15 to 80 relative humidity non condensin
5. Model M1770A M1771A M1772A PageWriter 300pi 200 100 Cardiographs Technical Data PageWriter 200 PageWriter 300pi Description HP offers an economical family of car diographs which include the M1772A PageWriter 100 M1771A PageWriter 200 and M1770A PageWriter 300pi The PageWriter 100 with simple easy to use operator controls generates reports in seconds Additional copies are also available at the push of a but ton The PageWriter 200 and 300pi cardio graphs print 12 lead ECGs in different formats and over extended periods for different clinical tests or applications The PageWriter 300pi is HP s econom ical interpretive cardiograph All three provide printed traces that use a continuous feed high resolution dig ital array printer This provides crisp easy to read electrocardiograms on standard page lengths that require no cutting or mounting Using an alphanumeric keyboard records are clearly labeled with ECG data and patient information PageWriter 100 Improved ECG Quality The PageWriter 100 provides extensive ECG quality control features includ ing AC noise filtering Additionally the PageWriter 200 and 300pi cardiographs provide baseline wander correction as standard and configurable filters that can be turned on from the keyboard to further sup press noise Their displays allows preview of any three leads at a time to verify ECG quality before recording ECG Measurements
6. ermal paper anti fade 8 5 x 11 M2486A 200 sheets Z fold thermal paper anti fade metric M2468A Reusable electrode kit for 4 mm posts IEC 40494E Electrode limb clamp 4 bx M2253A B Disposable tab electrodes M2254A Adapter clips for disposable tab electrodes M13943B Disposable tab electrodes M13946B Adapter clips for disposable tab electrodes M1770 90900 Service manual English only HEWLETT PACKARD i To Order Call DiaMedical USA www DiaMedicalUSA com Info DiaMedicalUSA com For more information please call your local HP sales office listed in your telephone directory or an HP regional office listed below United States Hewlett Packard Company Medical Products Group Headquarters 3000 Minutemen Road Andover MA 01810 Medical Customer Information 1 800 934 7372 Canada Hewlett Packard Canada Ltd 5150 Spectrum Way Mississauga Ontario L4W 5GI 905 206 4725 Latin America Hewlett Packard Latin America 5200 Blue Lagoon Drive 9th Floor Miami FL 33126 305 267 4220 Asia Pacific Headquarters Hewlett Packard Asia Pacific Ltd 17 21 F Shell Tower Times Square 1 Matheson Street Causeway Bay Hong Kong 852 2599 7777 Australia Hewlett Packard Australia Ltd A C N 004 394 763 61 3 9272 2698 China China Hewlett Packard Co Ltd 86 10 6 505 3888 India Hewlett Packard India Ltd 91 11 682 6000 Japan Hewlett Packard Japan Ltd 81 3 33
7. g to 4 550 m 15 000 ft altitude Environmental Storage Conditions 0 to 50 C 32 to 122 F 15 to 90 relative humidity non condensing to 4 550 m 15 000 ft altitude Physical Specifications Cardiograph Dimensions 115 mm H by 437 mm W by 392 mm D 4 in H by 17 in W by 15 in D Cardiograph Weight 8 5 kg lt 19 Ib Signal Processing Recording Frequency Response Selectable as follows PageWriter 100 Auto 0 15 150 or 0 15 40 Hz Manual 0 05 150 or 0 05 40 Hz Frequency Responses Selectable for both auto and manual from these ranges PageWriter 200 and 300pi 0 05 150 0 15 150 0 5 150 Hz 0 05 100 0 15 100 0 5 100 Hz 0 05 40 0 15 40 0 5 40 Hz Filters Noise filter On off capability Power line filter always enabled Configurable baseline wander noise and artifact filters PageWriter 200 and 300pi Standardization 1 mV 50 uV 200 ms 4 ms at 10 mm mV 25 mm sec Common Mode Rejection 110 dB or greater at power line frequency in any lead with 51 KOhms in parallel with 0 047 uF electrode impedance imbalance and up to 300 mV dc offset in any lead wire DC Offset Capability 300 mV dc at patient input Input Bias Less than 40 nA per input wire less than 500 nA for Right Leg drive output Input Impedance Greater than 15 MOhm at dc typically greater than 100 MOhm at dc Recording Technique High resolution digital array printer using thermal sensitive paper 200 DPI voltage axis by 500
8. t to change without notice 1998 Hewlett Packard Company Printed in U S A 5968 1039E