E5061B/E5063A Security Feature

image

Contents

1. Model Number s E5061 B E5063A Terms and Definitions Definitions Clearing Clearing is the process of eradicating the data on media before reusing the media so that the data can no longer be retrieved using the standard interfaces on the instrument Clearing is typically used when the instrument is to remain in an environment with an acceptable level of protection Sanitization Sanitization is the process of removing or eradicating stored data so that the data cannot be recovered using any known technology Instrument sanitization is typically required when an instrument is moved from a secure to a non secure environment such as when it is returned to the factory for calibration Agilent memory sanitization procedures are designed for customers who need to meet the requirements specified by the US Defense Security Service DSS These requirements are outlined in the Clearing and Sanitization Matrix issued by the Cognizant Security Agency CSA and referenced in National Industrial Security Program Operating Manual NISPOM DoD 5220 22M ISL O1L 1 section 8 301 Security erase Security erase is a term that is used to refer to either the clearing or sanitization features of Agilent instruments Instrument declassification A term that refers to procedures that must be undertaken before an instrument can be removed from a secure environment such as is the case when the instrument is returned for calibration Declassification p
2. memories are for board serial number board revision number Any user data is not stored in these memories Size 256 M Bit Memory clearing N A Memory sanitization N A Memory removal The E5061B Al A2 A3 A4 A9 and A11 modules need to be removed and replaced with a new or unused module as per the service manual See the E5061B Service Manual for more detail information on the procedure as well as the replacement parts Write protecting N A Memory validation N A Remarks Description and E5063A Non volatile memory flash for Al Modules These memories are for purpose board serial number board revision number and system calibration data Size 2 MB Memory clearing N A Memory sanitization N A Memory removal The E5063A A1 modules need to be removed and replaced with a new or unused module as per the service manual See the E5063A Service Manual for more detail information on the procedure as well as the replacement parts Write protecting N A Memory validation N A Remarks Storage removal E5063A E5061B 020 only for E5061B Because it is virtually impossible to completely and selectively erase all user data on a hard drive without also destroying the operating system the best method for maintaining security when the E5061B E5063A must be removed from a secure area is to replace the storage with a non secure hard drive i e a drive that has never had any sensitive data placed
3. E5061B E5063A Security Feature Rev 4 0 Agilent Technologies Feb 2014 Copyright 2010 2014 Agilent Technologies Page 1 of 11 Contacting Agilent Sales and Service Offices Assistance with test and measurements needs and information on finding local Agilent offices are available on the internet at http Avww agilent com find assist If you do not have access to the internet please contact your field engineer Note In any correspondence or telephone conversations refer to the signal generator by its model number and full serial number With this information the Agilent representative can determine whether your unit is still within its warranty period Page 2 of 11 Product Declassification and Security Product Name Network Analyzer Model Number s E5061 B E5063A Product Declassification and Security Model Number s E5061B E5063A Product Name Network Analyzer Product Family Name ENA This document describes instrument security features and the steps to declassify an instrument through memory sanitization or removal Table of Contents Terms and Definitions aisevpeckicyevesvyete Pend stag skbexe uiee neetee ee euieaes 4 StrUMOENE Memory noain ait ea N caus oi ne nese ce NN dave dies 5 Memory Clearing Sanitization and or Removal essere 6 User and Remote Interface Security s cic sascvaavanevercnsaranevseseevens 10 Page 3 of 11 Product Declassification and Security Product Name Network Analyzer
4. System calibration Agilent factory user under data E5061B personnel or by normal not user defined calibration operation calibration data labs Non volatile No Yes Module serial Calibration at E5061B N A Memory number Revision factory Al A11 Source The data is number Module not stored by user under System Calibration A2 Receiver Module normal Data E5063A Opt 3L5 operation A3 Receiver Module Opt xx5 50 ohm A4 Receiver Module Opt xx7 75 ohm A9 LF Source Bias Module Opt 3L5 E5063A Al Analog Module Page 5 of 11 Product Declassification and Security Memory Clearing Sanitization and or Removal Procedures This section explains how to clear sanitize and remove memory from your instrument for all memory types lt Memory type gt Description and Main Memory for Windows Operating system memory purpose Size Windows XP 2 GB Windows 7 4 GB Memory clearing Power rebooting This is a volatile memory Memory sanitization Power rebooting This is a volatile memory Memory removal This memory cannot be removed without damaging the instrument Write protecting N A Memory validation N A Remarks Description and Media Storage Hard Disk Drive Solid State Drive Memory removal purpose Size Windows XP HDD 160 GB Windows 7 SSD 80 GB Memory clearing N A Memory sanitization N A The storage drive needs to be removed and replaced with
5. a new or unused hard disk drive part as per the service manual Write protecting N A Memory validation N A Remarks Description and purpose Size Memory for DSP RAM for A51 DSP Module 1 8M bit Memory clearing Power rebooting This is a volatile memory Memory sanitization Power rebooting This is a volatile memory Memory removal This memory cannot be removed without damaging the instrument Write protecting N A Memory validation N A Remarks Description and Non volatile memory Flash for A51 DSP Module This memory is for product purpose serial number and option The system calibration data are also stored in the E5063A Any user data is not stored in these memory Size 64 MB Memory clearing N A Memory sanitization N A Memory removal The A51 DSM module needs to be removed and replaced with a new or unused module as per the service manual See E5061B E5063A Service Manual for more detail information on the procedure as well as the replacement parts Write protecting N A Memory validation N A Remarks Page 6 of 11 Product Name Network Analyzer Model Number s E5061 B E5063A Product Declassification and Security Product Name Network Analyzer Model Number s E5061 B E5063A Description and E5061B Non volatile memory EEPROM for Al A2 A3 A4 A9 and A11 purpose Modules These
6. eyboard and mouse to the connectors on the E5061B Turn on the E5061B 7 Press Macro Setup and press Load Project in the softkey menu 8 A dialog box will appear for you to select the program to load Select RestoreSysCorFile vba from the D Agilent Service folder and then press the Open button 9 Press Macro Run The RestoreSysCorFile dialog box will appear Click OK 10 Place the gen lic files into the E License directory Manually create the License directory if the directory does not exist The E5061B E5063A can now be used elsewhere or sent for servicing without fear of leaking any sensitive information Storage disk re installation procedure Page 8 of 11 Product Declassification and Security Product Name Network Analyzer Model Number s E5061 B E5063A Once the E5061B E5063A is returned to the secured area follow the steps listed below Any servicing of the E5061B E5063A may include the regeneration of correction constants 1 Remove the spare Unsecured hard drive and replace with the original Secured hard drive 2 Connect the external keyboard and mouse to the connectors on the E5061B E5063A Turn on the E5061B E5063A 3 Press Macro Setup and press Load Project in the softkey menu 4 A dialog box will appear for you to select the program to load Select RestoreSysCorFile vba from the D Agilent Service folder and then press the Open button 5 Press Macro Run The RestoreSysCorFile dialog box w
7. ill appear Click OK 6 Copy the gen lic files from your USB memory into the E License directory Manually create the License directory if the directory does not exist Note If your secured hard disk does not contain the RestoreSysCorFile vba program copy the program from the unsecured hard disk Page 9 of 11 Product Declassification and Security Product Name Network Analyzer Model Number s E5061 B E5063A User and Remote Interface Security Measures Screen and Annotation Blanking The frequency blanking feature is available This function provides three security levels OFF during normal operation Low deletes frequency information from the display but can be turned OFF by front panel operation and High deletes frequency information from the display and cannot be turned OFF except rebooting The operator can perform the following keystrokes to control this frequency blanking feature System gt Service Menu gt Security Level gt None Low High or set the levels by the following SCPI command SYSTem SECurity LEVel NONEILOWIHIGH Note Any SCPI COM commands that read the frequency data are not influenced by this function All commands can read frequency data regardless of the security level USB Mass Storage Device Security E5061B Windows XP Users can disable any USB compatible external mass storage devices in order to ensure confidentiality The following procedure shows h
8. on it This allows the E5061B E5063A to still function properly in non secured areas or for use when servicing The E5061B 020 and all E5063A have a removable storage on the rear panel Agilent has available a pre configured storage for the E5061B E5063A that must be purchased in order for this security method to work A spare disk is available as below Product Number Windows License See the Windows label on the Agilent Part rear panel Number E5061B Windows Vista Business Not Assigned Windows XP Pro for Embedded Systems E5061 65003 Windows Embedded Standard 7 E5061 65004 E5063A Windows Embedded Standard 7 E5063 65001 Note The limited number of times for removing connecting is 50 times Hard disk removal procedure These steps should be followed to maintain security Page 7 of 11 Product Declassification and Security Product Name Network Analyzer Model Number s E5061 B E5063A 1 Clearly mark the spare hard drive as Unsecured 2 If there is the file named lic under E License directory copy it into your USB memory This file contains software option information 3 Remove the two screws on the rear panel Remove the case with the hard drive and put it on AA 4 Disconnect both connectors from the HDD and then remove the four screws holding the hard drive to the case 5 Replace the original Secured hard drive with the spare Unsecured hard drive 6 Connect an external k
9. ow to disable a USB Mass Storage Device 1 Save Recall gt Explorer Double click DisableUsbStorage exe from D Agilent Service 3 Click OK in the SUCCEEDED message window that appears If any USB mass storage device is connected to the E5061B E5063A under this condition the Hardware Wizard will start but the USB mass storage device will not work The following procedure shows how to enable a USB Mass Storage Device 1 Save Recall gt Explorer 2 Double click EnableUsbStorage exe from D Agilent Service 3 Click OK in the SUCCEEDED message window that appears Note If you do not want any USB mass storage device to ever be enabled at any time delete Enable UsbStorage exe from the E5061B E5063A after DisableUsbStorage exe has been completed These two programs will not be recovered automatically by applying the firmware update or other such action Before deleting any of these programs you should make a backup copy to a recording medium such as a floppy disk and store it separately Note If the program fails to run it is possible that you have not logged in as a user in the Administrators Group When you want to execute any of the above programs make sure to log in as a user in the Administrators Group E5063A E5061B Windows 7 Refer to the following site http ena tm agilent com e5063a manuals webhelp eng index htm using windows enablingdisabling usb storage htm Page 10 of 11 Product Decla
10. rocedures will include memory sanitization and or memory removal Agilent declassification procedures are designed to meet the requirements specified by the DSS NISPOM security document DoD 5220 22M chapter 8 Page 4 of 11 Product Name Network Analyzer Model Number s E5061 B E5063A Product Declassification and Security Instrument Memory This section contains information on the types of memory available in your instrument It explains the size of memory how it is used its location volatility and the sanitization procedure Summary of instrument memory base instrument e S we Ze M be ZE ee ee AZ gs Data Input ee Sanitization Typeand 26 32 Purpose Contents Instrument and 2 35 Method Procedure Size Sa oe Remarks TE Ge eS Z I Main Yes No Windows Operating Operating A50 A60 A70 CPU Cycle power Memory system memory system not Module user defined Media Yes Yes Windows Operating User Saved HDD SSD assembly Remove Storage system boot device Data factory correction data and users file Operating including saved system not traces data settings user defined or images Memory for Yes Yes Data Processing for Measurement A51 DSP Module Cycle power DSP module measurement not user RAM defined Non volatile No Yes Product serial Adjustment A51 DSP Module N A Memory number Options Program The data is Flash performed by not stored by
11. ssification and Security Product Name Network Analyzer Model Number s E5061 B E5063A Remote Access Interfaces The user is responsible for providing security for the I O ports for remote access by controlling physical access to the I O ports The I O ports must be controlled because they provide access to all user settings user states and the display image The I O ports include USB GPIB and LAN The LAN port provides the following services which can be selectively disabled a http b ftp c sockets d telnet There is also a ping service which presently cannot be selectively disabled The concern might be that it is possible to discover IP addresses of connected instruments in order to query their setups over the net or break into the code Page 11 of 11