Home

Product Manual

image

Contents

1. pump has not been investigated for use in swimming pool areas DO NOT WORK ON PUMP UNTIL POWER IS UNPLUGGED DO NOT cut off ground pin or use an adapter fitting DO NOT use an extension cord The pump power cord should be connected to a separately fused grounded 115 volt line with a minimum capacity of 15 amps NEVER touch the pump when it is connected to electrical power The receptacle should be located at least 4 feet above floor level When wiring this pump follow all local electrical and safety codes and ordinances as well as the most recent National Electrical Code N E C ANSI NFPA 70 2000 12 118 5 Parts List Description Part No Laundry Tray Wet Bar Dehumidifier Water Softener Washing Machine etc not supplied BASIN SINK TANK BV Al SUMP PUMP COVER SINK BASIN GASKET COVER SCREW 10 32 X 3 4 PANHEAD PHILLIPS COVER SINK TANK STRAINER GASKET STRAINER STRAINER FASTENERS 1 4 20 X 5 8 PIPE 1 1 2 X 12 TOE GROMMET ELECTRICAL NAMEPLATE LABEL WARNING CARTON Co o nu DH F amp F WwW PY PP eS a w N e o 14 25530000 52623 000 1 255400001 23150074000 05434A061 25686A000 256888000 25685A000 18475A007 13665 018 3 256894000 14849 000 1 14848 000 1 14851 000 1 Inlet Pipe and Trap not supplied Vent Pipe A i not included Discharge Pipe and Check Valve not supplied 141 2 gt i U Gas tight Cover Diagram
2. 1 Pump Switch and Internal Piping 9 11 ILN WARRANTY Hydromatic Pumps warrants to the original purchaser of each Hydromatic Pump product s that any part thereof which proves to be defective in material or workmanship within one year from date of installation or 18 months from manufacture date whichever comes first will be replaced at no charge with a new or remanufactured part F O B factory Purchaser shall assume all responsibility and expense for removal reinstallation and freight Any item s designated as manufactured by others shall be covered only by the express warranty of the manufacturer thereof This warranty does not apply to damage resulting from accident alteration design misuse or abuse If the material furnished to the Buyer shall fail to conform to this contract or to any of the terms of this written warranty Hydromatic Pump shall replace such nonconforming material at the original point of delivery and shall furnish instruction for its disposition Any transportation charges involved in such disposition shall be for the Buyer s account The Buyer s exclusive and sole remedy on account or in respect of the furnishing of material that does not conform to this contract or to this written warranty shall be to secure replacement thereof as aforesaid Hydromatic Pump shall not in any event be liable for the cost of any labor expended on any such material or for any incidental or consequential damages to any
3. Pump System Installation and Service Manual HYDROMATIC 118 5 SYSTEM Sump Pump Hide Away Basin System 14 5 W 16 H 1 5 Discharge O pening NOTE To the installer Please make sure you provide FO this manual to the owner of the pumping equipment or to ry HYDROMATIC the responsible party who maintains the system Pentair Pump Group General Information Thank you for purchasing your Hydromatic product To help insure years of trouble free operation please read the following manual carefully Before operation Read the following instructions carefully Reasonable care and safe methods should be practiced Check local codes and requirements before installation Attention This manual contains important information for the safe use of this product Read this manual completely before using this product and refer to it often for continued safe product use DO NOT THROW AWAY OR LOSE THIS MANUAL Keep it in a safe place so that you may refer to it often Warning Before handling these pumps and controls always disconnect the power first Do not smoke or use sparkable electrical devices or flames in a septic gaseous or possible septic sump Pump Warning Warranty void if product is modified drilled painted or altered in any way if used to pump hot water or to pump liquids other than water such as but not limited to chemicals fertilizers flammable liquids herbicides mud tar cem
4. ent wood chips or otherwise abused The model 118 5 Hide Away Basin System is specially designed for pumping wastewater from laundry 2 trays washing machines wet bars water softeners dehumidifies etc This pump system installs above floor level no need to dig a sump This pump system cannot be used for laundry dishwasher applications in a commercial or industrial environment Installation Instructions Diagram 1 shows the various connections that must be made for proper installation and operation This is only a guide actual installation may vary depending on the particular situation Inlet A 1 1 2 inlet is provided on the 118 5 Hide Away Basin System One method of hookup is to use a 1 1 2 PVC MIP adapter or a 1 1 2 PVC MIP marvel connection or a similar type of connection You may use a 1 1 2 extension tailpiece or 1 1 2 PVC pipe it depends on the type of fittings used on the basin inlet The P Trap should be installed once the appropriate connections are made on the basin inlet Once these fittings are installed the rest of the piping may be plumbed Vent Provision have been made for a 2 vent to allow maximum volume for any application and proper operation of pump The vent may be reduced to no less than 1 1 4 Venting is essential for proper pump operation and should not be omitted The 118 5 Hide Away Basin System may be vented into an existing vent
5. ll Rights Reserved Part 5625 425 1 ltem W 03 423 3M 3 00
6. one by reason of the fact that such material does not conform to this contract or to this written warranty ALL IMPLIED WARRANTIES INCLUDING THE IMPLIED WARRANTY OF MERCHANT ABILITY AND THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE SAME EXTENT AS THE EXPRESS WARRANTY CONTAINED HEREIN Some States do not allow limitations on how long an implied warranty lasts so the above limitation may not apply MANUFACTURER EXPRESSLY DISCLAIMS AND EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ARISING IN CONNECTION WITH THIS PRODUCT INCLUDING WITHOUT LIMITATION WHETHER IN TORT NEGLIGENCE STRICT LIABILITY CONTRACT OR OTHERWISE Some States do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you PUMP MUST BE REPAIRED BY AUTHORIZED HYDROMATIC REPAIR CENTER OR WARRANTY WILL BE VOID IF REPAIR CENTER IS NOT AVAILABLE RETURN PUMP TO PLACE OF PURCHASE This warranty gives you specific legal rights and you may also have other rights which vary from State to State Your Authorized Local Distributor H tyDROMATIC Pentair Pump Group USA CANADA 1840 Baney Road Ashland Ohio 44805 www hydromatic com 269 Trillium Drive Kitchener Ontario Canada N2G 4W5 Tel 419 289 3042 Fax 419 281 4087 Tel 519 896 2163 Fax 519 896 6337 2000 Hydromatic Ashland Ohio A
7. stack or use a BOCA in line vent Check local codes Discharge Do not restrict discharge line below 1 1 4 A check valve MUST be installed to prevent backflow of water after each cycle If you are using 1 1 2 or 1 1 4 PVC pipe on the discharge line a Hydromatic s CV 170 check valve is recommended Once check valve has been installed plumb the discharge line into an existing drain line Basin Hydromatic s 118 5 Hide Away Basin System includes a corrosion resistant polypropylene tank with a gasket cover An inlet strainer is provided in the basin cover above the inlet The strainer is sealed and held in place with the four screws provided System Maintenance Caution Always disconnect pump from the electrical power source before doing any maintenance Your sink pump system is manufactured for easy maintenance Each unit is individually factory tested to ensure proper adjustment and operation If unit fails to operate properly carefully read instructions again to make sure correct procedure has been followed Electrical Information Note The basin strainer requires routine maintenance The strainer should be removed and cleaned monthly to prevent clogging WARNING Risk of electrical shock This pump is supplied with a grounding conductor and grounding type attachment plug To reduce risk of electrical shock connect only to a properly grounded grounding type receptacle This

Download Pdf Manuals

image

Related Search

Related Contents

manual de instrucciones  User ManUal PB50 - Snooper Services  

Copyright © All rights reserved.