Home
SERVICE MANUAL BFVSM-95
Contents
1. Included throughout this manual is the safety alert symbol you see to the left When you see this symbol be alert to the potential for personal injury SIGNAL WORDS Like DANGER WARNING or CAUTION are used with a safety alert symbol DANGER Immediate hazard which WILL result in severe personal injury or death WARNING Hazards or unsafe practices which COULD result in personal injury or death CAUTION Hazards or unsafe practices which COULD result in minor personal injury or product damage DO NOT attempt to modify any Tri Clover product To do so could create unsafe conditions and void all warranties DO NOT place any Tri Clover product in an application where general product service ratings are exceeded INTRODUCTION Thank you for purchasing a Tri Clover Product This manual contains disassembly and assembly instructions maintenance procedures and complete parts list for all Series A51L A52 and A53 Butterfly Valves designed and manufactured by Tri Clover Inc Kenosha Wisconsin READ THIS MANUAL carefully to learn how to service these valves Failure to do so could result in personal injury or equipment damage INSTALLATION Pre Installation Checks For convenience in packaging and storage the valve is shipped completely assembled When installing the valve it is necessary to O partially disassemble the valve and reassemble it in place 5 Verify installation dimensions Table 1 lists the dimensions required for asse
2. expressly in lieu of any other warranties express or implied including but not limited to any implied warranty of merchantability or fitness for a particular pur pose All claims must be in writing and must be mailed or delivered by purchaser within thirty 30 days after purchaser learns of the facts upon which such claim is based Any claim not made in writing Tri Clover Inc 9201 Wilmot Road i i Tri Clover Canada Kenosha Wisconsin 53141 1413 101 Milner Avenue 414 694 5511 Scarborough Ontario M1S 4S6 FAX 414 694 7104 416 299 5490 International Sales 414 697 3170 FAX 416 299 5095 FAX 414 694 8188 and within the time period specified above shall be deemed waived Purchaser s sole and exclusive remedy and Tri Clover Inc s maximum liability for claims arising hereunder or for negligence for any and all losses and damages resulting from any cause shall be either the repair or replacement of defective items or at Tri Clover Inc s option the refund of the purchase price for such items In no event including in the case of a claim for negligence shall Tri Clover be liable for incidental or consequential damages including loss of profits No person including any representative employee or agent of Tri Clover is authorized to assume on behalf of Tri Clover Inc any liability or responsibility in addition to or different from that described inthis provision Any and all representations promises warranties or
3. soyenjoe adj JalAeay P SeJinbeJ YoIUM y deoxe pasojo ewou 10 u do AjjeWOU se pesn eq ueo sio en15Vv Y Jaysemyoo7 N Jaysemyoo7 1 USP A m s deg Bu usng Apog Jemo osiq yeas Maos deg N 15S deg Apog seddn INN J ysemy207 Mas deg JEH 19M0 NOA eH ddn 810A Jejdnoo Joyenjoy uo d oseq 6 8 Zi 9L SL vi El ol Lh 0L GN c LO OR OOD Koy Bumeig 104 sabe Buiwollo3 89S se es esy onewn ud V INQd3 2 2 11 116V ejduuexq yelayew yeas JO 991049 LNO ALIYM eseaid syed ulueo8jdeJ Buli pio UBYM uollsnjuo2 DIOAE O S 8IJ9 8UJ JAS J8U O JO IJQ8 I8 8 10 J90 O IJ 98 U0O enau Waag seyeubisap 3 piepue s se papiAoid SI Naag ON way enarew zeoas JO 391049 s leuBis p seyo 9A0QE uo sueadde yise Xu SS 0081VM1 SS 0081VM 4 0081 N SS H9LELOS 80 1S 91 4S0 1S 916 QS0 6 1G X r 8 LS V 0 L0 dLS V g0 10 8 16 V LO W10 2S V LO WLO E YLS V LO W10 1S uS V X TY ESV V X TESV SS O0ELVM1 SS O0ELVM F HOOELNN SS H9LELOS 80 2 12 LS 91 3q60 4 g 1G 9LE dS0 2 2 LS X Sv 2 1e kG V 20 10 2 12 Y LS V g0 10 4 g 1G V LO WLO 2 12 2S V LO WLO 2 2 Y LS V LO WLO 2 12 LS ule V X77 i0 TH LSV VW X 12 T ESV SS O0ELVM1 SS 00E LVM A HOOELNN SS H9LELOS V80 2 1S 9L 4S0 2 1S 9LE CS0 2 1S X V v c LIS V c0 W10 2 YLS V c0 W10 2 1S V L0 10 2 2S V LO GL0 2 Y LS V L0 g1L0 c LS nc VW X 1H
4. statements that are in addition to or different from the terms of this provision are of no force or effect Distribution Centers in Union City California and Memphis Tennessee Tri Clover Mexico Recursos Petroleros No 7 Fracc Ind La Loma 54060 Tlalnepantla Edo de Mexico e PHONE 52 5 397 0601 FAX 52 5 362 3246 Alfa Laval BFVSM 95 Printed in August 1995
5. 0ELVM1 SS O0ELVM1 SS O0ELVM SS O0E LVM SS H9LE LOS SS H9LELOS 80 1S 80 2 2 1G V 20 10 6 16 V 20 10 4 2 16 91 6 G0 1G 91 3q60 4 g 16 X ZF 8 16 X ZV 4 g 1G SS J420819S SS HZ069S SS H90L LOS SS HZOLLOS V LO WLO 2S V LO WL0 2 12 2S SUON SUON bait SS OOLLYVMT SS OOLLVM1 SuoN SS HZOLLOS SUON S 20 V2f 4 1 26 S WLb 2S S LO WLb 2 12 2S S COL 2S S 01 2 12 2S abed sno e d 0 Jajay uf ui V X 8XXXX3 gSV V X 6 XXXX CSV SS qQS0L LOS SS qQS0L LOSS S Qo98 4 1 18 S Q98 4 1 168 VS 90 S8tr c LS VS 90 S8r c LS S S8r 1LS S S8rF c 1LS uf u V X 141SV V X ic 184 SV V X TESV V X 12 TESV SS 006VM1 A HOOELNN SS 00ELVM1 SS 00E LVM SS H9LELOS V80 c LS V 0 VL0 c L S 9L 4S0 2 1S X Ver o lS SS HZ069S SS H90L LOS V LO 10 2 2S SS HOOL LAN SS 001 LVA SS H901 LOS S 20 WLb 4 1L 2S S L0 VZf 4 1 cG S QO0L1 g c6 ne V X 8XXXZ3 zSV SS qQS0L LOS S Q98 4 1 168 VSE 90 D8r c 1S S 98p Z 149 uG v X z 14 LSV V X c 1LSV SS O006VM1 1 ysemy207 6L 4 H0081f N NN gL SS 00ELVM1 J ysemy207 ZI SS 00 LYM 1 ySEM 94 SS H9LELOS m s deo SL 80 2 1 18 Bu usng rh V g0 V10 4 1 1GS Apog J9Mo7 l 916 360 4 1 1G osiq zL X VZv 7 LS yeas LL SS HZO069S malas deo OL SS H90L LOS Malas deg 6 V LO G1L0 2 b 2S Apog seddj g SS H00L1 N INN Z SS 00L YMI JaysSemyo07 9 SS H904 LOS MeJ9S deg S S 20 V2F 4 1 28 HEH J801 YO v S L0 VZY 7 1 28 HeH Jedd
6. 416SV V X c 1LSV SS O0ELVM1 SS O0ELVM A HOOELNN SS H9LELOS 80 41 18 918 360 4 1 16 918 Q6S0 4 1 1G X Ver Fib bS Ve0 VL0 2 b Y LS V g20 V10 4 1 1G V L0 810 4 1 2GS V 10 810 Z 1 H1G V L0 810 4 1 16S w b V X E THLSV V X 2 L 1TESV lpueu Bupiool ejn JeJ Ssajssaded GO eqn 4 LSY 10 pys lpueu Buly90 GO eqn T1SV J8US8M gt 907 1 YSEM NN M S Bu usng SV SV 9SIQ Td 1ESV SIA xx 88S T4 LSW Apog 19m0 TLSVv Apog Jam07 ESY ZSV Apog seddn 74 LSv Apog seddy 1 Sv A pog eddn Uuo nd o2seq El ol LL Ol 6 No S Koy sanjen Aysayng sales EGY ZSV 11SV D PARTS LIST Manual A51L Series All orders for repair parts must contain the following data 1 Complete model number 2 Complete description and part number Pneumatic Actuator and Electric Actuator To order replacement parts for the Tri Clover Butterfly with Pneumatic Actuator and Electric Actuator include all the information asked for below Valve Replacement Parts To order valve replacement parts the valve part number must be included with your order To obtain the part number of the valve you have refer to the sample part number below and build the part number of your valve A53A P2200 3 E A 1 2 3 4 5 1 Valve Series Actuator 2 3 Valve Size 4 Seat Material 5 External Body Material Actuator Replacement There are no model or serial numbers o
7. Test the operation of the valve Be sure that the butterfly disc shuts off completely when it is moved to the closed position When it is completely shut both edges of the disc are in the same position on the gasket so that the same amount of gasket is showing on both sides of the disc If it does not shut completely adjust the travel of the operator by following the adjustment procedure for either the electric or pneumatic OPERATORS Manual Pneumatic Electric Alignment Mark Each valve should have an alignment mark at the bottom end of the stem as shown in illustration at right This mark is in line with the butterfly disc It allows checking the disc position when the valve is installed in the line When an older valve without a mark is disassembled for service mark it before reassembly Clamp the disc securely and carefully make a permanent alignment mark on the bottom end of the stem The mark must be exactly in line with the disc Be extremely CAREFUL to mark the stem correctly Manual Alignment Mark Handles and Stop Plates One of three different handles are used on Tri Flo Butterfly Vales depending on size Note that a locking handle is now furnished as standard on every size valve The locking handle permits position locking of the valve disc in OFF ON or any intermediate position This standard handle cannot prevent intentional valve position tampering Pneumatic Installation 80 psig air supply required The followin
8. TriClover_ButterflyValve_A51_A52_A53_install_D895 SERVICE MANUAL BFVSM 95 TRI CLOVER BUTTERFLY VALVE SERIES A51L A52 A53 Se Tri ciover Inc TABLE OF CONTENTS INTRODUC TON eae Z u u E A caste 3 SAFETY snare casavsssedaveeaevs wis dsevecnsvvaveecrsacesviuceisavacssnveeed seca corvdaesdaneacurviediedempeusauededsneaseris 3 INSTALLATION si u naninioinln Mara kinin niya Sala nesaz ei pan ea sira sedaane aaa asied deaan rindan Erai 4 REMOVALAND DISASSEMBLY ei asan ananassa neka qaa qasa naka e kana naka a Wana n n ai 5 REASSEMBLY AND REINSTALLATION i kk keke kk kk k k kK KK KAK KAKA kK AA kk 5 OPERATOR Siei usa u TAL Mu ban usan ad leke REK Kad e da dR H kar badan heyn nda a 6 PARTS LIST A51L A527 ASS BUTTERFLY VALVES i siiui seina da sa kh da b h D ka b e da h W da bna d d n d h asas asus 8 MANUAL AS TIL SERIES dica ccescsavetsstasacssanesess dadan biny nn j a soatvegesd dat cus ka W n dada b k wa d d hi y dadan b n x z k 10 PNEUMATIC ACTUATOR ii y misil haxina ah kak i d han k Waa i k MER B han ik b a RWE R h WEQ lT W i R 10 ELEGTRIGACTUATOR ssaccsscesscttsessetenstsstavesiiseatasageisas ba n w na R n e h e du h R A b p REWA bn b k V b i uh x Ghan 10 SAFETY Safety is very important
9. amp bolt and hex nut from the valve stem and handle Remove the handle from the stem NOTE It is not necessary to remove a pneumatic or electric operator to disassemble a valve 3 Using box or socket wrenches of the correct size release and gt remove the hex nuts screws lockwashers and washers which clamp the body halves together 4 Insert the blade of a screwdriver in the end slot between the body halves separate the body halves and release the valve from the Tri Clamp connectors of pipe end adapters 5 Remove the seat gasket and butterfly disc assembly 6 Rotate the butterfly disc to the open position Squeeze the seat gasket into an ellipse and remove the bushings 7 Refer to illustration below Squeeze the seat gasket into an ellipse raise the butterfly disc and release the lower stem end The butterfly disc may then be removed 8 Inspect all parts for wear or damage Replace the seat gasket if cracked worn or deformed Replace stem bushings if cracked or worn Replace butterfly disc if cracked or worn Replace screw or nuts if they have stripped or damaged threads REASSEMBLY AND REINSTALLATION WARNING To prevent personal injury keep hands and tools away from butterfly disc when actuating an electric or pneumatic operator The operators actuate with sufficient force to cause serious injury 1 Refer to illsutration at right Squeeze the sides of the seat gasket until it forms an ellipse Insert the stem of th
10. e butterfly disc with the hex end into the upper hole in the gasket Locate the lower end of the stem in the gasket hole Reshape the gasket and test the action of the butterfly disc The disc should turn freely Disc 2 Install the bushings in the body halves with the grooved end of each Assembly Seat bushing into each body half 3 Lubricate the cavities of the body halves and the faces and outer rim of the gasket with Tri Clover Silicone Spray No L 1011B 4 Place the butterfly disc in the open position Position the seat gasket and butterfly disc assembly between Tri Clamp connectors or Tri Clamp pipe end adapters place the body halves with bushings installed over the Tri Clamp flanges and press together as far as possible by hand NOTE A normally closed electric or pneumatic operator will have to be opened to put the body halves together NOTE Make sure the bushings are properly located in the body halves 5 Fasten the body halves together with the screws washers lockwashers and nuts Tighten the nuts alternately and evenly until the body halves meet Using box or socket wrenches of the correct size tighten the nuts to 30 ft lb 6 Forthe Series A51L Manual Operator depress the handle trigger and position the handle on the butterfly stem The handle should fit well down over the stem but must clear the top plate Secure the handle in place by tightening the clamp screw and the hex nut with wrenches of the correct size 7
11. g Solenoid valves are available Connect air supply to solenoid valve as illustrated in the schematics to the right Solenoid Selection Chart 4 7 4 7 NEMA RATING 110 VAC 220VAC VOLTAGE 60 HZ STD 33 205 110 33 205 220 3 Way Normally Closed Oen 33 204 110 33 204 220 3 Way with Flow control 33 183 110 33 183 220 4 Way 33 181 110 33 181 220 4 Way with Flow control H Air SPL E NOTE Dissembly of the pneumtaic actuator is not recommended I Contact Tri Clover for service center location and repair instructions Adjustment Double Acting The limits of rotation are changed by setting the adjusting screws in the cylinder ends The closing limit is regulated by the adjusting Z screw on the right hand side short end of cylinder The opening limit is regulated by the adjusting screw on the left hand side long P lt end of cylinder An adjustable wrench is suitable for the lock nuts and screws N A B E Hz Loosen the lock nuts on the adjusting screws Apply air pressure to the OPEN port to open the valve If the butterfly disc does not open all the way or rotates too far turn the OPEN adjusting screw in or out to adjust the limit of opening rotation On air to spring actuators release the air pressure to close the valve On air to air actuators apply the air pressure to the CLOSE port to close t
12. he valve If the valve does not close completely or rotates too far turn the CLOSE adjusting screw in or out to adjust the closing limit of rotation NOTE Before turning an adjusting screw operate the actuator in the opposite direction This will remove pressure from the adjusting screw so it can be easily turned After each adjustment operate the actuator several times in each direction and recheck the adjustment When the adjustments are satisfactory tighten the lock nuts Electric Thermal Installation qa dera Overload A standard wiring diagram is shown to the right i Brown Disassembly of the Electric Actuator is not A C LINE NO recommended Contact Tri Clover for service a Black o NC center location and repair instructions G CAMS SPDT Qo D Red Brake Adjustment Control S L 4 NC Optional Remove the cover The limits of rotation are O E ui en 9 NO 7 _ _ _ adjusted by the cams which actuate the mirco AIAIOI TO switches The upper cam controls the closing Field Actuator ae iri j Terminal Strip limit The lower cam closest to valve controls Wiring Wiring the opening limit Refer to picture below To adjust a cam loosen the set screw in the cam to free it from the shaft move the cam in the desired direction and retighten the set screw The set screws in all actuators require 1 6 inch Allen wrench IMPORTANT To avoid stri
13. lover Silicone Spray No L 1011B 5 Place the butterfly disc in the open position Position the seat gasket and butterfly disc assembly between Tri Clamp connectors or Tri Clamp pipe end adapters place the body halves with bushings installed over the Tri Clamp flanges and press together as far as possible NOTE Make sure the bushings are properly located in the body halves Make sure the butterfly stem and actuator shaft are properly inserted in the coupling before proceeding to the next step 6 Secure the body halves with the screws washers lockwasher and nuts Tighten the nuts alternately and evenly until the body halves meet Using box or socket wrenches of the correct size tighten the nuts to 30 ft Ib 7 Test the operation of the valve Be sure that the butterfly disc shuts off completely when it is moved to the closed position When it is completely shut both edges of the disc are in the same position on the gasket so that the same amount of gasket is showing on both sides of the disc REMOVAL AND DISASSEMBLY WARNING To prevent personal injury relieve pipe line pressure and drain A all fluids completely WARNING To prevent personal injury disconnect all electrical and pneumatic power to an operator The operators actuate with sufficient force to cause serious injury 1 Open the valve to flush and drain the line in which the valve is located Close the valve 2 Refer to illustration at right Remove handle cl
14. mbly of Series A Tri Flo Butterfly Valves to a piping run LAJ Dimension A in Figure 1 is the distance required between fixed Figure 1 Tri Clamp connectors Refer to Table 2 for the dimensions Compressed Seat required for specific adapters other than Tri Clamp Width for All Connectors Check pipe end alignments If the valve is to be installed VANS Tube OLE between fixed Tri Clamp ends the faces of the Tri Clamp ends must be parallel in all planes and on the same centerline IMPORTANT Failure to have fixed pipe end openings both parallel and in alignment will prevent proper sealing of the Tri Clamp ends to the valve seat gasket An improperly sealed valve may leak Flanged Bevel Seat Bevel Seat A52 amp A53 Hex Nut ACME ACME End Table 2 Installation Procedure 1 Remove the valve and operator from the shipping package Inspect for damage incurred during shipping or storage Do not attempt to install a damaged valve Ba 2 Refer to illustration at right Using box or socket wrenches of the correct s size unfasten and remove the hex nuts screws and washers which NN N fasten the body halves together a 3 Remove the bronze bushings from the seat gasket and butterfly disc assembly Inspect each bushing and note that one end is smooth the other is grooved Install the grooved end of each bushing into the body halves 4 Lubricate the cavities of the body halves and the faces and outer rim of the seat gasket with Tri C
15. n 340A S QOL1 4 1 cS Jejdnoo z Jo en 9V d l uo d oseq V X XXX2 3 CSV SOLES ZY 911 99 3 pueu Bulyool ss ss 5 1 GO qnl Tq LSY 40 pls lpueu Buryoo GO eqn 1ISV SS Q60010S M S r S q98 Z 1 16 9 8 d dois WSE 90 D8P iL LS A89 S lpueH z S O8 4 1 11S A quiassy lpueH L hL uo nd oseq Aay V X L TH ESV V X z L 1LSV s TLSV IenuelN 11 Tri Clover manufactures a complete line of TRI WELD fittings TRI CLAMP fittings BEVEL SEAT fittings POSITIVE PUMPS CENTRIFUGAL PUMPS AUTOMATIC Air Actuated VALVES STAINLESS STEEL TUBING AUTOMATED FLOW CONTROL SYSTEMS Terms Warranty Provisions Notice of Claims and Limitation of Liability Prices and all terms and conditions of sale are established in current price sheets and are subject to change without notice All orders are subject to acceptance by Tri Clover Inc at its Kenosha Wisconsin or Distribution Center offices only No assignment of the purchaser s rights may be made without consent of Tri Clover Inc Each Tri Clover item is warranted to be free from manufactur ing defects for a period of one 1 year from the date of shipment providing ithas been used as recommended and in accordance with recognized piping practice and providing ithas not been worn out due to severe service suchas encountered under extremely corro sive or abrasive conditions This warranty is
16. n the actuator therefore obtain the correct actuator part number from the table below knowing the valve size and for the Electric Actuators the actuator voltage PNEUMATIC ACTUATOR Valve Actuator Part Number Size Air to Air Air to Spring 11 2 2 A53A P2000 53 P2400 21 2 A53A P2100 53 P2500 a A53A P2200 53 P2600 4 A53A P2200 53 P2600 NC 53 P44100 NO All pneumatic actuators can be used normally open NO or normally closed NC except 4 size above ELECTRIC ACTUATOR Valve Actuator Actuator Part Number Size Voltage Waterproof Explosion Proof 11 2 120 A52 E7000B A52 E7000B 2 220 A52 E7100B A52 E7100B 21 2 3 120 A52 E2800B A52 E3000B 4 220 A52 E2900B A52 E3100B Actuator for 11 2 and 2 sizes varies in appearance from larger sizes housing is semi round rather than retangular Manual Electric Pneumatic See Previous Page for Parts List Et rrr N N QI N N GN SS p bay ON erret p bay on SS 0081VM1 4 H0081 N SS 0081VM1 SS 0081VM SS H9LELOS 80 7 LS V 20 10 F 1GS 916 1S0 F 1G X Zf y 1G SS 44Z0E10S SS HZOLIOS V L0 8L0 r LS SuoN bait SS OOL LVM SUON SUON S VLb 2S S d0l p 2S ud V X r XXXX3 SV SS qQS0L LOSS S 998 t LS VS 90 S8r r LS S S8r r 1LS ub V X b TY LSV V X b TLSV SS O0ELVM1 SS 006VM1 A HOOELNN F HOOELNN SS O
17. on pasinbay SUON S VLv 2S S G01 7 2S ub O N V X t 009Zd E SW WV X 8 009Zd 8 SV O N V X r 00Lrbd 8 SV SS O0ELVM1 SS 00 LVM A HOOELNN SS H9LELOS 80 7 1S 9L 4S0 b 1S 9b dS0 1S X ev v lG V c0 LO Y LS V 20 L0 b 1S V 10 410 Y 1G V L0 gL0 rF dIS V 1L0 gL0 r LS ul V X b TY ESV V X b TLSV SS 00ELVM1 3a H0081 N SS 00ELVM1 SS 00 LYM SS H9LEL OS 80 LS V G0 10 8 1G 918 360 8 1G X ov E LG SS 4d420810S SS H90110S V LO WLO 2S UON be 4 SS 0011VM1 painbay SUON pasinbeay SUoN S VLb 2S S d0l 2S uf SS 006VM1 A HOOELNN SS 00ELVM1 SS 00 LYM SS H9LE LOS 80 4 2 16 V 20 10 2 12 LS 918 36S0 4 g 1G X lt V amp LS SS H9060S SS H 0L LOS V LO WL0 2 12 2S uoN SS 00LLYMI SS HZOLLOS S g0 V2f 4 1 S S LO VZY amp cS S d0 2 12 2S abed Bu moj oJ o1JeJeH PAIK V X 12 0060d ESV SS 006VM1 A HOOELNN SS 00ELVM1 SS O0ELVM SS H9LELOS V80 2 1S V 20 W10 2 LS 9L 4S0 2 1S X cb c LS SS H9069S SS H901 LOS V L0 G10 2 2S SS HOO L LAN SS 001 LVM SS H901 LOS S Z0 YZt 7 L 29 S LO0 YZt 7 L 29 S d0L z Z9 n V X 2 00bed ESV SS 006VM1 A HOOELNN SS 0081VM1 SS 0081VM SS H9LELOS 80 41 18 V g0 V 10 1 18 918 360 2 1 16 X dV 4 1 LG SS H9060S SS H90L LOS V L0 8L0 b 2S SS H00L LAN SS OOLLVM1 SS H901 LOS S G0 V2f 4 1 cS S L0 VZY 4 1 cS S QO01 4 1 26 u th V X L O0bed ESV u do Ajjwesou 104
18. pping threads tighten set screws firmly but not excessively Connect all wires to the appropriate terminals to open the valve If 3 the butterfly disc does not open completely or rotates too far disconnect the wires and adjust the OPEN limit cam Limit Cam Connect all wires to the appropriate terminals to close the valve If the butterfly disc does not close completely or rotates too far disconnect the wires and adjust the CLOSE limit cam After each adjustment operate the actuator several times in each direction and recheck the adjustment When the adjustments are satisfactory install the cover IMPORTANT When installing the cover be sure the wires are placed where they will not be pinched between the cover and the internal parts PARTS LIST A51L A52 A53 Series Butterfly Valves All orders for repair parts must contain the following data 1 Complete model number 2 Complete description and part number The following exploded view and accompanying parts list facilitate order repair parts from the factory All parts illustrated are indexed to the parts list by key numbers ji 10 0 SOS QN cO N F rr GN NN f GN GN lt p bay ON re rrr rT rT NNT A p boy on SS 00ELVM1 A HOOE LNN SS 00ELVM1 SS 00 LYM SS H9LELOS 80 r LS V 0 L0 r LS 918 3S0 r LIS X CvV V LS SS 4 420810S SS HZOLLOS V L0 810 F 1GS UON be 4 SS OOLLWM1 pauinbay su