1. _ Agilent e o P Series Power Meters and o0 P Series Wideband Power Sensors amp o o o e Mig ai ma Configuration Guide P Series Power Meters N1911A Power Meter single channel N1912A Power Meter dual channel P Series Power Sensors N1921A Power Sensor 50 MHz to 18 GHz N1922A Power Sensor 50 MHz to 40 GHz fe Agilent Technologies Introduction This configuration guide describes standard configurations options and compatible accessories Contact your local Agilent representative for additional information P Series Power Meters The P Series power meters provide peak average peak to average ratio power measurements time gated and free run modes rise time fall time and pulse width measurements The P Series power meters are compatible with the 8480 E Series and new P Series power sensors The P Series power meters have a different sensor input connector than the EPM and EPM P Series power meters so it is necessary to use adapter cables These adapter cables come in three different lengths When using the 8480 or E Series sensors refer to the Cable Accessories section in this guide For additional information refer to the Literature References section The standard P Series power meters include Single channel power meter order N1911A or dual channel power meter order N1912A Input sensor connector s on the front panel e Reference calibrator 1 mW 50 MHz connector
2. Direct Latin America 305 269 7500 www lxistandard org United States 800 829 4444 LXI is the LAN based successor to GPIB providing faster more efficient Asia Pacific connectivity Agilent is a founding Australia 1 800 629 485 member of the LXI consortium China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Agilent Channel Partners Japan 0120 421 345 Korea 080 769 0800 wwwagilent com find channelpartners Malaysia 1 800 888 848 Get the best of both worlds Agilent s Singapore 1 800 375 8100 measurement expertise and product Taiwan 0800 047 866 breadth combined with channel Thailand 1 800 226 008 partner convenience Europe amp Middle East Austria 43 0 1 360 277 1571 Belgium 32 0 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 0 10 855 2100 France 0825 010 700 0 125 minute Germany 49 0 7031 464 6333 lreland 1890 924 204 Israel 972 3 9288 504 544 Italy 39 02 92 60 8484 Netherlands 31 0 20 547 2111 Spain 34 91 631 3300 Sweden 0200 88 22 55 Switzerland 0800 80 53 53 United Kingdom 44 0 118 9276201 Other European Countries www agilent com find contactus Revised October 1 2009 Product specifications and descriptions in this document subject to change without notice Agilent Technologies Inc 2009 Printed in USA October 27 2009 5989 1252EN aes Agilent Technologies
3. options for P Series power meters Option Description N1911A 003 Rear panel sensor and power reference connectors single channel N1912A 003 Rear panel sensor and power reference connectors dual channel Video output option H01 The video output provides a DC voltage proportional to the measured input power through a BNC connector on the rear panel The DC voltage can be displayed on an oscilloscope for time measurement This option replaces the recorder output on the rear panel The video output impedance is 50 0 e Video rise time 13 ns Frequency range 50MHz to 40GHz 1 The Installation Guide is in English French and Japanese languages p n N1912 90009 2 The P Series power meters are configured for either front panel connectors both sensor and power reference or rear panel connectors There are no options for parallel front and rear panel sensor inputs 3 Need to turn off the auto zero feature otherwise this will appear as a glitch in the video output signal P Series Power Meter Accessories Standard accessories are available for example rack mount kits Table 2 P Series power meter accessories Accessory Part Description Number N1911A 908 Rack mount kit one instrument N1912A 908 N1911A 909 Rack mount kit two instruments N1912A 909 34131A Basic instrument transit case 34161A Accessory pouch Cable Accessories Power sensor adapters for use with 8480 and E Series power sensors Ta
4. ble 3 Cable accessories for use with 8480 and E Series power sensors Accessory Description Part Number N1917A P Series meter cable adaptor 1 5 m 5 ft N1917B P Series meter cable adaptor 3 m 10 ft N1917C P Series meter cable adaptor 10 m 31 ft Software Accessories N1918A PC analysis software PC analysis software will be available in May 2007 for complete pulse and statistical analysis The PC analysis software links with the P Series power meter via the LAN USB or GPIB interface in a PC or laptop environment It provides the comprehensive statistical power frequency and time measurements that are required for radar and communications signals P Series Wideband Power Sensor Cable Lengths Three fixed cable length options are available for the P Series power sensors at 1 5 m 3 0 m and 10 m Option 105 is the standard default option Table 4 P Series wideband power sensor cable lengths Option Description N1921A 105 Fixed 1 5 m 5 ft cable length N1922A 105 N1921A 106 Fixed 3 m 10 ft cable length N1922A 106 N1921A 107 Fixed 10 m 31 ft cable length N1922A 107 Calibration Option The P Series power meters and sensors are available with Option 1A7 18017025 compliant calibration or Option A6J ANSI Z540 compliant calibration Service and Support Options The P Series power meters and sensors are supplied with a 1 year customer return repair service as standard Table 5 Service and support opt
5. ions Option R1280A R1282A Description Return to Agilent warranty and service plan Return to Agilent calibration plan Documentation The P Series power meters are supplied with a printed copy of Installation Guide a printed copy of English language User s Guide Option ABA and a Product Reference CD which contains the User s Guide and Programming Guide The following tables supply the option number as well as the Agilent part number where appropriate to order the documentation The localized options for the P Series power meters provide a printed copy of the localized User s Guide and an English language printed copy of the Programming Guide The P Series power sensors provide a printed copy of the Operating and Service Manual as standard Table 6 Documentation Option Documentation N1911A 0B0 Delete manual set N1912A 0B0 N1911A 0BK Additional English language manual set N1912A 0BK User s Guide p n N1912 90002 and Programming Guide p n N1912 90009 N1911A 0BF English language Programming Guide N1912A 0BF p n N1912 90009 N1911A OBW Service Guide p n N1912 90015 N1912A 0BW N1911A ABF French localization User s Guide part number N1912A ABF N1912 90003 N1911A ABJ Japanese localization User s Guide part N1912A ABJ number N1912 90007 N1921A 0B1 Additional English language manual set N1922A 0B1 Operating and Service Manual part number N1920 90007 Literature References P Series Power Me
6. on the front panel Printed copy of Installation Guide e Printed copy of English language User s Guide CD ROM contains the English language and localized User s Guides and the English language Programming Guide Supplied accessories power cord plug matches country destination requirements e USB adapter cable p n 8121 1354 CA ASSY USB type A B plugs 4 cond 6 0 ft P Series Wideband Power Sensors The P Series wideband power sensors are designed specifically for operation with the P Series power meters for wide bandwidth power and time measurements These sensors are the only Agilent power sensors that have their cable permanently wired hard wired into the sensor This provides better wide bandwidth specifications compared to having a removable cable Refer to the Sensor Cable Lengths section in this guide for part number and cable length information The standard P Series power sensors include e Power sensor 50 MHz to 18 GHz order N1921A e Power sensor 50 MHz to 40 GHz order N1922A e English language Operating and Service Manual p n N1920 90007 Compatibility Power sensor compatibility The P Series power meters are compatible with all current 8480 E Series and P Series power sensors Refer to the Accessories section P Series meter cable adaptors N1917A B and C Connector options for P Series power meters The following options are available on the P Series power meters Table 1 Connector
7. ters and Power Sensors Technical Overview literature number 5989 1049EN P Series Power Meters and Power Sensors Data Sheet literature number 5989 2471EN EPM P Series Power Meters and E9320 Sensors Data Sheet literature number 5980 1469E EPM Series Power Meters E Series and 8480 Series Power Sensors Data Sheet literature number 5965 6382E Fundamentals of RF and Microwave Power Measurements Part 1 Application Note 1449 1 literature number 5988 9213EN Fundamentals of RF and Microwave Power Measurements Part 2 Application Note 1449 2 literature number 5988 9214EN Fundamentals of RF and Microwave Power Measurements Part 3 Application Note 1449 3 literature number 5988 9215EN Fundamentals of RF and Microwave Power Measurements Part 4 Application Note 1449 4 literature number 5988 9216EN 4 Steps for Making Better Power Measurements Application Note 64 4D literature number 5965 8167EN Choosing the Right Power Meter and Sensor Product Note literature number 5968 7150E www agilent com www agilent com find powermeters For more information on Agilent Technologies products applications or services please contact your local Agilent office The complete list is available at www agilent com find contactus ia Agilent Email Updates www agilent com find emailupdates Get the latest information on the products and applications you select Americas 3 Canada 877 894 4414 Agilent D Gitene

Download Pdf Manuals

image

Related Search

Configuration configuration configuration manager configuration manager console configuration meaning configuration editor configuration tool configuration synonym configuration manager properties configuration management tools configuration manager remote control configuration item configuration settings configuration manager trace log tool configuration wizard configuration management plan configuration office configuration manager windows 11 configuration editor equalizer configuration manager client configuration manager sql server configuration manager console windows 11 configuration management database configuration properties configuration manager client download configuration editor equalizer apo