Service Manual – G4 ThermoPro 1 Gallon Twin
Contents
1. Q 50 1 3 cm VESSEL CLEARANCE USING OPTIONAL HIGH VOLUME BREW CONE Electrical Schematic ThermoPro 1 Gallon Twin G4TP1T 10 BRN 10GA POWER BLOCK BRN 10GA 57 654 300 450 THERMDSTAT MAN RESET DPST SSR 1 40A 277V 40A 600V BLU 10GA BLK 10GA BLK 10GA INCOMING POWER ad 208 240Vac IR TOGGLE SW p SSR 1 H2 3W G SPST 40A 600V B B 15A 125 250V 50 60 Hz RED 10GA RED 10GA HEATING ELEMENTS 3X 2 5KW 220V STP GRY CHASSIS FUSE GROUND _ 5A 250V GRY ALTERNATE TRANSFORMER WIRE HOOKUPS BREW CONE LOCK RIGHT 14 PIN CONNECTOR 20 CONNECTOR BREW CONE LOCK LEFT OPTIONAL COMPONENT HEATING TANK 2 0 GPM 10W 120V STP VIO INLET VALVE 5 GPM 12W 120V BREW VALVE RIGHT 8 PIN CONNECTOR UPM GROUND BREW VALVE LEFT BYPASS VALVE RIGHT STP BRN 5 GPM 12W 120V BYPASS VALVE LEFT Data Communication First UNIVERSAL TOUCH SCREEN 12Vac 5 SHIELDED CABLE 5 CONNECTOR UNIVERSAL POWER MODULE 120Vac 5WVac SER WARMER RIGHT m BLU BLU 100W 120V s m 6 z GRY STP RED BLK MER 777 e GRINDER 100W 120V S f INTERLOCK 2 l o 4 GEMINI UNITS ONLY GRY 5 1 amp H2 CONNECTION 5KW FACTORY DEFAULT BRN WIRE IS CAPPED amp
2. WILBUR Curtis Co INc Service Manual G4 ThermoPro 1 Gallon Twin Important Safeguards Symbols This equipment is designed for commercial use Any servicing other than cleaning and routine maintenance should be performed by an authorized Wilbur Curtis Company Service Technician DO NOT immerse the unit in water or any other liquid To reduce the risk of fire or electric shock DO NOT open service panels There are no user serviceable parts inside Keep hands and other items away from hot areas of the unit during operation Never clean with scouring powders or harsh chemicals Symbols WARNINGS To help avoid personal injury Important Notes Cautions from the factory Model 2 Sanitation Requirements GATP1T This Curtis Generation 4 Unit is Factory Pre Set and Ready to Go Right from the Box Following are the Factory Settings for your G4 Coffee Brewing System Brew Temperature 200 F Water Bypass LARGE amp MEDIUM Brew Only Brew Volume Set to Vessel Requirement CAUTION Please use System Requirements ene Water Source 20 90 PSI Minimum Flow Rate of 1 GPM before attempting to use this brewer Failure to follow the Electrical See attached schematic for standard model or visit www wilburcurtis instructions can result in injury or the com for your model voiding of the warranty SETUP STEPS e IMPORTANT Equipment 1 The unit should be level left to right front to back on
3. Once power has been supplied to the unit flip the toggle switch to the ON position located on the rear of WILBUR CURTIS CO INC the unit the water tank will begin to fill When the water level in the tank reaches the probe the heating 6913 West Acco Street element s will turn on Montebello CA 90640 5403 For the latest information go to 5 Water in the heating tank will require approximately a half hour before reaching operating temperature www wilburcurtis com factory setting of 200 F Where applicable turn on the Universal Control Module UCM When the unit Tel 800 421 6150 reaches operating temperature it will display READY TO BREW For the latest specifications and information go to www wilburcurtis com 1 QUICK START ThermoPro Your Curtis G4 Gold Cup Series is Factory Pre Set for Optimum Performance After connection to water and power turn on the brewer at the rear toggle switch You will hear a beep and the status lights will come on for a moment The screen will display Next is displayed Water will fill the tank 2 3 minutes depending on water flow rate When the proper level is reached will appear on the screen It takes approximately 30 minutes to reach the set point temperature Control will display when temperature reaches the set point The unit is now ready to brew COFFEE BREWING INSTRUCTIONS 1 Brewer should be ON Confirm this at the toggle switch on the back of the br
4. Only dl One Batch Two Batch Three Batch One Batch Two Batch c Three Batch One Batch Two Batch ii E Three Batch One Batch Two Batch Menu Features RECIPES FUNCTION TO SET SETTING RANGE FACTORY SET DEFAULT NOTES COMMENTS Gourmet STD Light Roast Dark Roast High Global Recipes Yield Filter Pack Decaf Gourmet STD Home CONTROL SETTINGS FUNCTION TO SET SETTING RANGE FACTORY SET DEFAULT NOTES COMMENTS Temperature 175 F 206 F 1 F Tank Temp 200 F Settings Increments Minimum Brew Temp 195 F Disabled 1 Hr 12 Hr 1 lt gt Increments ON GEMT CEMS Note This function is only visible on Gemini Units Warmer Settings HERE n 10 Hr on GEMTIF GEMSIF gt Increments OFF HIGH lt MED gt LOW MED During Brewing Disabled 20min Quality Timer 240min 10 Minute Increments Audible alarm when time is expired Only shows available Disabled on GEMT GEMS TP2T TP2S OMG TPC2T TPC2S gt when a machine has Warmer lt 120min on GEMTIF GEMSIF gt Elements Also this function is visible when Gemini models are selected Tank temperature is maintained at No Change the temp setpoint default Energy Save Mode Activates after 4 Turn Tank Heater Off No Change Tank is turned off Reduce tank temp Tank temperature maintained at 140 F 140F Hide Models GEMT
5. STOWED FOR 7 5KW CONNECTION REMOVE CAP ON BRN WIRE 10GA amp peo CONNECT TO POINT C ON POWER BLOCK 2 USE THIS DIAGRAM FOR ALL OTHER MODELS WITH ADDED PREFIX LETTERS AND OR SUFFIX NUMBERS ON THEIR PART NUMBERS HAVING THE SAME ELECTRICAL RATINGS 1 ALL WIRES SHALL BE 18AWG UNLESS NOTED ELECTRICAL RATING TABLE USE 187 NOTES UNLESS OTHERWISE SPECIFIED HEATING warmers TOTAL TOTAL LUG POWER CURRENT MACHINE ur H2 LeFT RIGHT WATTS AMPERES AMPERAGE SEE TABLE 2 1 2 1 1 1 1 5100 WIRES 3W G TP2T10 TPC2T10 TP1T10 TP1TT10 2 1 1 1 GS ejeje 7600 GEMTSTO amp GEMINIO Loo zs AMPERAGE SEE TABLE TME apts remo e o s Iz 5 01 LADDER DIAGRAM 230 LD GTPTG4 10 rv E Cleaning the ThermoPro Regular cleaning and preventive maintenance is essential in keeping your coffee brewer looking and working like new To clean the coffee brewer and components prepare a mild solution of dish washing detergent and warm water CAUTION Do not use cleansers bleach liquids powders any other substance containing chlorine These prod ucts promote corrosion and will pit the stainless steel USE OF THESE PRODUCTS WILL VOID THE WARRANT Y DAILY CLEANING Wipe exterior surfaces with a damp cloth removing spills and debr
6. located in the top cap and the other is in the bottom faucet shank c Using the narrow brush provided for this purpose brush out the inside of the glass with a detergent solution Rinse the sight glass tube of all detergent residue d Clean and rinse the washers Replace if necessary e Pay special attention to the small gauge glass liquid level hole on the shank Use a narrow brush to clean this hole f Replace the sight glass Make sure the top and bottom silicone washers are seated After cleaning return the handle assembly onto the faucet Carefully assemble the parts Make sure the faucet and gauge glass properly seal CAP UNSCREW BONNET TOP WASHER ASSEMBLY FROM FAUCET BODY BOTTOM WASHER GAUGE GLASS GUARD RS BRUSH OUT HOLE AT BASE QUU OF GAUGE GLASS SHANK 17 Product Warranty Information The Wilbur Curtis Co Inc certifies that its products are free from defects in material and workmanship under normal use The following limited warranties and conditions apply 3 Years Parts and Labor from Original Date of Purchase on digital control boards 2 Years Parts from Original Date of Purchase on all other electrical components fittings and tubing 1 Year Labor from Original Date of Purchase on all electrical components fittings and tubing Additionally the Wilbur Curtis Co Inc warrants its Grinding Burrs for Forty 40 months from date of purchase or 40 000 p
7. 8559 RELAY SOLID STATE 40A w INTEGRATED HEAT SINK 8 WC 3503 LEG 3 8 16 STUD SCREW BUMPBER 9 WC 3518 LEG GLIDE 3 8 16 STUD SCREW 10 WC 58037 102 COVER CENTER WRAP 11 WC 5983 101 PANEL TOP WRAP BACK 12 WC 847 VALVE INLET 2GPM 120V 10W 12A WC 883 VALVE INLET 2 GPM 240V 10W EXPORT UNITS ONLY 13 WC 1501 FUSE HOLDER ASSY w 5A FUSE 14 WC 102 SWITCH TOGGLE NON LIT SPST 15A 125 250VAC RESISTIVE 14A WC 103 SWITCH TOGGLE DPST 25A 125 250VAC EXPORT UNITS ONLY RECOMMENDED PARTS TO STOCK 11 Illustrated Parts Top Wrap 12 ITEM NO PART NO 15 16 17 17 18 18 19 19 20 20 21 22 23 24 WC 2977 101K WC 43089 WC 442 WC 446 WC 37122 WC 854 WC 589 101 WC 589 102 WC 13450 WC 13450 101 WC 10000 WC 4212 02 WC 29050 WC 10008 DESCRIPTION KIT SPRAYHEAD FITTING PLASTIC GASKET 1 00 OD x 625 I D x 030 RED SILICONE 40 SHORE SOLENOID LOCK BREW CONE RIGHT 120VAC SOLENOID LOCK BREW CONE RIGHT 220V EXPORT UNITS ONLY KIT DUMP VALVE RIGHT VALVE BREW DUMP RIGHT 240V 12W EXPORT UNITS ONLY TRANSFORMER 120VAC 24VAC 4 8VA W TERMINALS TRANSFORMER 240VAC 24V 4 8VA W CONNECTOR EXPORT UNITS ONLY HARNESS ASSY COMPLETE G4TP2T G4GEMT G4GEMTIF HARNESS ASSY COMPLETE EXPORT UNITS ONLY CONTROL MODULE TOUCH SCREEN G4 NUT 5 8 18 JAM PLASTIC ULTEM SPRAYHEAD ASSY AFS AMBER UNIVERSAL HOST A
8. DAPTER USB RECOMMENDED PARTS TO STOCK Illustrated Parts Heating Tank ITEM NO PART NO 25 26 27 28 29 30 31 92 33 34 35 36 WC 37008 WC 43067 WC 37266 WC 5527K WC 37317 WC 37357 WC 62033 WC 934 04 WC 1438 101 WC 522 WC 4382 WC 43055 DESCRIPTION KIT TANK LID ROUND O RING 4 1 2 1 0 x 8 285 C S SILICONE KIT FITTING TANK OVERFLOW 8MM KIT PROBE WATER LEVEL O RING amp NUT KIT STRAIGHT FITTING amp BUSHNG 8MM KIT STRAIGHT PLASTIC FITTING KIT STRAIGHT PLASTIC FITTING TANK COMPLETE GEMTS W ULTEM FITTINGS KIT ELEMENT HEATING 2 5KW 220V W JAM NUT amp SILICONE WASHERS SENSOR TEMPERATURE TANK THERMOSTAT HI LIMIT HEATER DPST 277V 40A GUARD SHOCK HEATING ELEMENT GUARD SHOCK RESET THERMOSTAT RECOMMENDED PARTS TO STOCK 13 Illustrated Parts ITEM NO PART NO 37 GEM 6 38 WC 5310 39 WC 5350 40 WC 10001 40A WC 10015 41 WC 596 Rough In Drawing 24 75 62 9 cm 13 63 33 0 cm 4 13 00 34 8 DESCRIPTION FILTER 500PK GEM 12 230A TUBE 5 16 ID x 1 8W SILICONE SOLD PER FOOT TUBE SILICONE 01 2 ID x 03 4 OD x 1 8 WALL SOLD PER FOOT UNIVERSAL POWER MODULE G4 120V UNIVERSAL POWER MODULE G4 220V EXPORT UNITS ONLY FILTER NOISE EMI 250VAC 30A EXPORT UNITS ONLY NOT SHOWN RECOMMENDED PARTS TO STOCK
9. G DESCRIPTION CAUSE Brew count Gallons Since Reset exceeds programmed Preventative Maintenance period Maintenance Required Maintenance Required If the Inlet valve remains on longer than XX Seconds during the brew cycle only and repeats TWICE during that brew cycle It shall clear upon the next brew and if the same low flow exists again it will re appear XX Alpha 20 secs Gem TP Twin 40 secs Gem TP Single 30 secs Low Water Flow Warning Low Water Flow ERROR MESSAGES STOPS BREWING MESSAGE DISPLAY ERROR DESCRIPTION The fill solenoid has either run for more than 10 minutes on the initial tank fill or 120 Seconds on Large Brewers and 30 Seconds on CGC Brewer in normal operation Water Level Error Fill run error Overflow Break in the temperature thermistor circuit or short Sensor Error Open Sensor curculf The sensor is reading that temperature in the Over Temp Error Excess Temperature heating tank has risen above 210 F or sensor has shorted to ground Internal Error 1 UPM UCM Communication Break in the UPM UCM Communication circuit Brew Access Code LG Lo A A MD m Ready to brew m B MD SM Tap Curtis Logo 5 Times to Enter Programming Mode ENTER AGGESS CODI 2 n f RECIPES CONTROL SETTINGS BREW SETTINGS SETTINGS SUMMARY MODEL SELECT Temp Settings PASSWORDS Quality Timer Programming Password Edit Energy Saving Disabled Enabl
10. GEMS TP2T TP2S OMGT OMGS Quality Timer Hide Show Displays Quality Timer Show Models GEMTIF GEMSIF Rinse Server Hide Show Show Displays Rinse Server Message Service Telephone Off 1000 to 20000 Gallons 1000 Increments Number Resettable Resettable For maintenance purpose Resettable Reprogrammoble allows access Programming 1234 to programming screens Passwords Reprogrammable allows access Brew Enabled Disabled Disabled E p a a s rene Master Reset OI med Are you sure Yes No Select to Reset to Restore Factory Defaults 22222 n 7 0 7 793 S 0 O Y U U T S 7 7 7 7S U 7 CC Display Settings Maintenance Interval Prev Maintenance 1 800 000 0000 x0000 Menu Features Brew Settings FUNCTION TO SET SETTING RANGE FACTORY SET DEFAULT NOTES COMMENTS Brew by OFF 30sec to Volume 19Min 59sec Brew by 0 to 19Min 59sec Time 1 01 increments When this is Chosen COLD BREW LOCK set to 5 F Pulse Brew On Off Function Disabled Disabled 10 secs On 10 secs Off When this is Chosen COLD BREW LOCK set to 5 F Pulse Brew On Off Function lt Disqbled gt 30 secs On 30 secs Off When this is Chosen COLD BREW LOCK set to 5 F Pulse Brew Pre Infusion Disabled On Off Function Disabled LARGE BREW 1320z 40z using a Amber AFS Sprayhead To Set Press Brew to start Press Brew to stop SMALL BREW 4oz 4oz using a Amb
11. Storage capacity should be 2 GB minimum reference the illustration on page 2 IMPORTANT The flash drive must be completely blank Before starting please erase any files that may be in the USB drive SOFTWARE INFORMATION TRANSFER UPLOAD TO USB 1 Make sure the brewer is on Determine that the G4 brewer you wish to copy is properly programmed for your desired settings 2 Connect an empty flash drive into the USB port on the brewer The UCM on the brewer will upload all of the particular setup data onto the flash drive The yellow LED on top of the touch screen will light indicating that data is transferring This will only take a second to complete DOWNLOAD TO BREWER 1 Select the brewer you wish to make the program changes on The brewer should be on 2 Plug the loaded flash drive into the USB port on the brewer The data copied from the first G4 brewer will automatically down load overwriting all the settings that were on the second brewer 3 The red LED on the UCM will indicate that the download is in process This will only take a second 4 Once the download is complete the UCM will reboot in order for the changes to take effect 5 Remove the flash drive The download is complete The data on the flash drive can be downloaded into as many G4 brewers as needed USB File Transfer This screen will be presented whenever the USB flash is inserted as long as UCM is showing main brew screen and is not cur rently brewing T
12. a secure surface to be installed to comply I I ics 2 Connect the water line to the water inlet fitting the of the unit Water volume flow to the machine with applicable govern 5 jJ mental plumbing electrical codes should be consistent Use tubing sized sufficiently to provide a minimum flow rate of one gallon per minute having jurisdiction MM purged from the cartridge prior to connection to equipment In areas with extremely hard water we highly recommend the use of a Curtis approved water filter For our full line of filters please log on to www Wilburcurtis com e NOTE A water filtration system must be used to help maintain trouble free operation Air must be CAUTION DO NOT connect this brewer to hot IMPORTANT water The inlet valve is NSF International requires the following water connection not rated for hot water NSF 1 A quick disconnect or additional coiled tubing at least 2x the depth of the unit is required so that the unit can be moved for cleaning 2 This unit must be installed with adequate backflow protection to comply with applicable federal state and local codes 3 Water pipe connections and fixtures directly connected to a portable water supply shall be sized installed and maintained in accordance with federal state and local codes 3 Connect the unit to electrical outlet with appropriate amperage rating see serial tag on machine ISO 9001 2008 REGISTERED 4
13. be 4 Allow some time for the probe to cool before working on the brewer 5 Clean the tip of the probe using a Scotch BriteTM scuff pad 6 If a residual white layer is still visible on the probe remove the probe and soak it in vinegar or a scale removing chemical Re peat this step until the white layer is removed 7 When assembling the probe back onto the tank make sure the tip of the probe is pointing downward as illustrated 16 Cleaning the Thermoserver 1 Fill the liner with a mild detergent solution and let it stand for 10 to 15 minutes O O N Drain coffee from the server After about 15 minutes take a sponge brush and scrub out the stainless steel liner When clean drain out the soapy solution from the server Fill the server with clean water to rinse detergent from inside the unit Repeat this rinsing until the water runs clear CLEANING OF THERMOSERVER FAUCET 1 Remove the faucet handle assembly Take hold of the bonnet and turn counterclockwise to unscrew it from the faucet 2 Clean the handle assembly with a mild detergent solution Once it is clean rinse it off with water Inspect for cracks or tears in the seat cup Replace the seat cup if damaged 3 With servers having a coffee level gauge glass follow these cleaning instructions 4 a Remove the top cap of the gauge glass guard and pull out the glass tube b Carefully remove the two washers that seal the glass tube One is
14. ed Brew Password Diagnostics A Display Settings Prev Maint Brew Counter Passwords Master Reset Regional Settings The Password screen will display two selections Programming Password or Brew Password To set up or change the brew password press the Enable button then the Edit button The Brew Password screen will appear When resetting a password press clear then select a new password numbers only If enabling the brew password select a password code Press the enter icon to set the new password Press home icon to return to main menu and exit USB Easy Programming There are two methods that can be used to change the default settings on G4 brewers They can be programmed at the brewer by the touch screen universal control module UCM or the settings can be changed using the USB Universal Serial Bus data port on the side of the brewer Using the USB connection and a flash memory data storage device will easily reprogram the settings simply by copying data The flash drive can upload or download the entire setting from one G4 brewer into another G4 brewer This eliminates the need to walk through the usual steps in reprogramming that would be required when you use the touch screen to make a change This is an advantage for a service technician when standardizing the program settings on multiple G4 brewers Use a USB drive with USB 2 0 support and a type A USB connection
15. equipment 4 Improper water supply This includes but is not limited to excessive or low water pressure and inadequate or fluctuating water flow rate 5 Adjustments and cleaning The resetting of safety thermostats and circuit breakers programming and temperature adjustments are the responsibility of the equipment owner The owner is responsible for proper cleaning and regular maintenance of this equipment 6 Damagedin transit Equipment damaged in transit is the responsibility of the freight company and a claim should be made with the carrier 7 Abuse or neglect including failure to periodically clean or remove lime accumulations Manufacturer is not responsible for variation in equipment operation due to excessive lime or local water conditions The equipment must be maintained according to the manufacturer s recommendations 8 Replacement of items subject to normal use and wear This shall include but is not limited to light bulbs shear disks 0 rings gaskets silicone tube canister assemblies whipper chambers and plates mixing bowls agitation assemblies and whipper propellers 9 Repairs and or Replacements are subject to our decision that the workmanship or parts were faulty and the defects showed up under normal use All labor shall be performed during regular working hours Overtime charges are the responsibility of the owner Charges incurred by delays waiting time or operating restrictions that hinder the service technicia
16. er AFS Sprayhead LARGE BREW 3min 32sec using a Amber AFS Sprayhead Note These are the default times for a Amber AFS Sprayhead SMALL BREW 1min 52secs using a Amber AFS Sprayhead When this is Chosen COLD BREW LOCK set to 5 F Pulse Brew On Off Function Disabled When this is Chosen COLD BREW LOCK set to 5 F Pulse Brew ON s s ON On Off Function Disabled When this is Chosen COLD BREW LOCK set to 5 F Pulse Brew PO secs On On Off Function Disabled 10 seconds ON 4 Times 10 seconds OFF 4 Times then ON Till End of Brew Cycle 1 Minute ON 10 seconds OFF 4 Times 10 seconds 4 Times Till end of Brew Cycle 25 seconds ON 5 Times 20 seconds OFF 5 Times then C C ON Till End of Brew Cycle Pulse Brew On Off D Manual Program PULSE COUNT 1 to 20 pulses ON TIME 5 150 seconds OFF TIME 5 150 seconds 5 second increments E Manual Program PULSE COUNT 1 to 12 pulses ON TIME 0 150 seconds OFF TIME 1 150 seconds 1 second increments By Pass Off 5 50 in 1 LARGE BREW 10 using a Amber AFS Sprayhead Note These are the default times for a Amber AFS Sprayhead On Off SMALL BREW Off using a Amber AFS Sprayhead iz um DEMENS C 227777 7242 Off 10 Seconds 15min ou UU UU increments System Fault Messages WARNING MESSA GES ALLOWS BREWING MESSAGE DISPLA Y WARNIN
17. ewer The touch screen should read Ready to Brew 2 Place an empty coffee container centered beneath the brew cone grounds and is difficult to manage with one hand WARNING AVOID SCALDING USE BOTH HANDLES FOR BETTER CONTROL The brew cone may be filled with hot coffee The coffee vessel is heavy when full Take precautions to avoid dropping while moving CAUTION 3 Place a new paper filter into the brew 4 Fill the brew cone with the proper 5 Transfer the filled brew cone to the cone amount of ground coffee brewer ENTER BREW CODE 6 Start the brew cycle by hold your finger requires a code to be entered before a brew During the brew cycle an animated 1 2 will start The default is OFF gallon server icon will appear on the screen dn Dvd Dese ted 2 CAUTION When enabled as soon as you and a brew timer will count down the time your finger enter the brew code a brew cycle starts remaining on the brew cycle Brew Code You may find that when a brew Refer to page 8 for more information about the Brew Code button is pressed a key pad appears on the screen This is a brew lock out feature that 2 Touch Screen Control Module The touch screen turns on when power is available to the controller The screen will contain standard control feature such as symbols and buttons Press ing these elements with your finger tip will activate the programming functions The default screen as well as some added cont
18. he default action is No action The UCM will always create a backup on the USB flash drive before downloading settings recipes or screen saver If a firmware update file is present on the USB flash the firmware update procedure will be started BEFORE this screen is shown FILE TRANSFER Upload Download to USB from USB Case 1 Settings recipes file Settings recipes e e present screen saver not pres Present on USB ent User has selected Down load from USB for settings Screensaver O recipes file Not present on USB No action FILE TRANSFER Upload Download to USB from USB Case 2 As above but user has Setti ngs reci pes No action selected Upload to USB for set Present on USB will be overwritten tings recipes file With this action the overwrite Screensaver E Not present on USB warning appears 10 Illustrated Parts Main View 4 L 79 10 ITEM NO PART DESCRIPTION 1 WC 5459 COVER TOP WRAP 2 WC 37121 KIT DUMP VALVE LEFT 2A WC 853 VALVE BREW DUMP LEFT 240V 12W EXPORT UNITS ONLY 3 WC 844 101 VALVE BYPASS 120V 14W NON ADJUSTABLE w RESTRICTOR WC 2945 3A WC 844 102 VALVE BY PASS 220V NON ADJUST W RSTRCTR EXPORT UNITS ONLY 4 WC 3417 BREW CONE ASSY W SPLASH POCKET BRWN STYLIZED HOT COFFEE 5 WC 1825 FAUCET ASSY HOT WATER 6 WC 14045 101 CURRENT SENSOR ASSY G4 7 WC
19. is Slide the brewcone out and clean it Wipe the sprayhead area with a cloth soaked in a mild detergent solution Rinse with a cloth soaked with clean water Dry the brewcone and sprayhead area Drain drip trays of coffee Water rinse pow mx Dry the tray WEEKLY CLEANING 1 Reach behind the brewer and turn off the power at the toggle switch Allow the brewer to cool 2 Clean the sprayhead and dome plate area a Remove the sprayhead unscrewing counterclockwise from the dome plate b Thoroughly clean and rinse the dome plate area c Clean the brewcone rails with a brush soaked with a mild detergent solution Rinse the area with a cloth soaked with clean water removing any residual detergent d Dry the area c Attach the sprayhead Liquid Level Probe Cleaning intervals for the probe are to be determined by the user or the service tech based on water conditions The use of water filters or the type of water filter that is being used can impact the service interval Intervals can be from one month to several years however replacing rather than cleaning the probe is preferable WARNING Disconnect electrical power before removing access panels This procedure involves working with hot water and hot surfaces 1 Unplug the power cord and shut off the water line 2 Remove the top cover of the unit Locate the top of the tank and remove the cover 3 Drain the tank to a level about 3 below the tip of the pro
20. n s ability to perform service is the responsibility of the owner of the equipment This includes institutional and correctional facilities The Wilbur Curtis Co Inc will allow up to 100 miles round trip per in warranty service call RETURN MERCHANDISE AUTHORIZATION All claims under this warranty must be submitted to the Wilbur Curtis Company Technical Support Department prior to performing any repair work or return of this equipment to the factory All returned equipment must be repackaged properly in the original carton No units will be accepted if they are damaged in transit due to improper packaging NO UNITS OR PARTS WILL BE ACCEPTED WITHOUT A RETURN MERCHANDISE AUTHORIZATION RMA RMA NUMBER MUST BE MARKED ON THE CARTON OR SHIPPING LABEL All in warranty service calls must be performed by an authorized service agent Call the Wilbur Curtis Technical Sup port Department to find an agent near you 16523 4 23 15 rev B v2 WILBUR CURTIS CO INC 6913 Acco St Montebello CA 90640 5403 USA Phone 800 421 6150 Fax 323 837 2410 Technical Support Phone 800 995 0417 M F 5 30A 4 00P PST E Mail techsupport wilburcurtis com Web Site www wilburcurtis com 5 2015 F 3964 rev B
21. ounds of coffee which ever comes first Stainless Steel components are warranted for two 2 years from date of purchase against leaking or pitting and replacement parts are warranted for ninety 90 days from date of purchase or for the remainder of the limited warranty period of the equipment in which the component is installed All in warranty service calls must have prior authorization For Authorization call the Technical Support Department at 1 800 995 0417 Effective date of this policy is April 1 2003 Additional conditions may apply Go to www wilburcurtis com to view the full product warranty information CONDITIONS amp EXCEPTIONS The warranty covers original equipment at time of purchase only The Wilbur Curtis Co Inc assumes no responsibility for substitute replace ment parts installed on Curtis equipment that have not been purchased from Wilbur Curtis Co Inc The Wilbur Curtis Co Inc will not accept any responsibility if the following conditions are not met The warranty does not cover and is void under the following circumstances 1 Improper operation of equipment The equipment must be used for its designed and intended purpose and function 2 Improper installation of equipment This equipment must be installed by a professional technician and must comply with all local electrical mechanical and plumbing codes 3 Improper voltage Equipment must be installed at the voltage stated on the serial plate supplied with this
22. rol buttons are shown in the illustration below STATUS LIGHTS BREW BUTTONS CURTIS LOGO TO ENTER PROGRAMMING Tap Curtis logo 5 times to bring up the ACCESS CODE screen CONTROL SYMBOLS All of these symbols may not be visible at one time RETURN TO HOME UNDO SCROLL RETURN TO PREVIOUS PROGRAMMING ENTER ACCESS CODE 22 MAIN MENU 5 Control Settings Brew Settings Model Select amp Settings Summary Ca ACCESS CODE screen Default is 1 2 3 4 MAIN MENU screen contains six control icons Once the code is entered press OK The RECIPES CONTROL SETTINGS BREW SETTINGS Main Menu screen will appear MODEL SELECT SETTINGS SUMMARY and EXIT The access code can be reset in Control Settings PASSWORDS PROGRAMMING Continued Menu Tree This chart explains how to enter the program mode and menu selections available from the MAIN MENU Tap Curtis Logo 5 Times to Enter Programming Mode RECIPES CONTROL SETTINGS BREW SETTINGS usns parme Stes Select Button Enter 1 2 3 4 to access the Main Menu SETTINGS SUMMARY MODEL SELECT Gold Twin Twin Twin Twin Thermopro 1 Gal af GE Twin When Installing New Control Board Default is Gemini Twin Three Batch Applies to Gemini Models Only Applies to Gold Cup Seraphim Models