SUPER FREE MATCH SERIES SERVICE MANUAL T1/R410A/50Hz
Contents
1. 98 52 OF o eee 98 5 3 Combinations for Outdoor and Indoor 99 5 4 Selection of Installation Location bte here tese oe e Ebene 99 5 5 Outline Dimension and Servicing Space 100 5 6 Outline Dimension and Servicing Space 101 9 7 Om InStr CHOTE UE 102 6 REFRIGERATION PIPING WORK 004 103 6 1 Manifold Mode of Connecting 9 103 6 2 Allowable Length and Drop Height of Connecting 104 6 3 Dime nsion Of COnmecting PIpDe sio 105 O24 CONE CHO OF 105 6 9 Desion Requirements for Oil Up ns 106 6 6 Connection of Outdoor Unit Refrigerant 107 6 7 Installation Adapte oppo te ee 108 6 8 Pr cautton TOF CONNECTION eiu an Cav ent tiu 109 110 110 Gans E 111
2. Hor HH S i E 5 PEINE D HL i pui Inlet air Axial Flow Fan Gas side stop valve Liquid side stop valve INSTALLATION Super Free Match Service Manual 3 4 Parts and Components of Unit For the super free match series system one outdoor unit is able to drive up to three BU modules and nine indoor units which include cassette type duct type wall mounted type floor ceiling type and console type The outdoor unit will run as long as any one indoor unit receives the running command and all indoor units stop once the outdoor unit is turned off Indoor unit T Cassette type B E BU J wel Grounds sont Wall mounted type ie Branch pipe 2 i Ground 2201 Outdoor unit lt 2 4 Branch pipe 3 Ground NEN Power 50Hz 220 Power 50Hz 380V 7 INSTALLATION Super Free Match Service Manual 3 5 Selection of Installation Location The installation of the air conditioner must be in accordance with the national and local laws and regulations The quality of the installation will affect the capability of air conditioner directly The insta
3. MAINTENANCE 7 Super Free Match Service Manual GFH 24 EA K3DNAIA I 35 dd 31 30 29 28 Cd 4 p3 22 Part list GFH 21 EA K3DNAIA I for CN210N0040 24 for CN210N0050 GFH 21 EA K3DNAIA I Air outlet frame assy 01375224 Water Tray Assy 01285334 T a No s owe Cover Piate 1 6 1 7 Piste ofthe Evaporator 01 1 Plate of the Exit Tube Sub Assy 0 ee 197 MAINTENANCE Super Free Match Service Manual 9 Frontvotute casing __ 19 299936 4 u Bottom Coverite 1 uu 1 4n 1 1 a5 Capacitor 1 16 J 1 1 9 Cover Plate oftheran 1 29 Temperature Sensor 399058 1 m 39906 1 m m Msn eme 1 sont Stack 1 7 x Rotary Anis Sub Assy 1 m 4
4. Super Free Match Service Manual GTH 24 BA K3DNAIA I 34 33 Part list PB 26 284 N 23 GTH 24 BA K3DNAIA I for CN610N0040 GTH 24 BA K3DNAIA I NO Description Cable Cross Loop 76510021 Louver Clamp 26112127 LE 4 Gude over 2 s Front Comecting Plate 1 260980 4 2648 MAINTENANCE Super Free Match Service Manual 9 Induced air plete subassembly Ja 1 u _______________ 1 m 260835 4 1 4 109830 4 Supporter osa d 6 suporto Motor Bearing omaes 3 i m ER Right Cover Pte 1 Installation Supporting Frame 0180402 1 n 0 3 E m i iSw s 1 3 Bucmp 26 Hoop subassembly 4 Drainage 1 Fh WA 1 30 A me me IN me a 1 3299 40 a Cet Cover Plat
5. iue 1 _ Pipe Clamp 1 _ 08394 1 _ x Step Motor iux 1 m mk 1 3m 1 _ 3 Guide Lower eps 1 _ Aiemh lw 1 x ume 1 _ 339808 1 _ Sd 3 1 Stied coverof Recron 1 _ 3 Clete Box Cover 1 _ 4 Cold plasma generator m Em MAINTENANCE E E Super Free Match Service Manual Change GWH 07 KF K3DNA6E I GWH 09 KF K3 DNA6E I GWH 12 KF K3 DNA6E I WH 18 KG K3DNA6E I Part list GWH 07 KF K3DNAGE I for CB146N26201 GWH 09 KF K3DNA6E I for CB146N26301 GWH 12 KF K3DNA6E I for CB146N26401 GWH 18 KG K3DNAGE I for CB146N26501 GWH 07 KF K3DNA 6E I GWH 12 KF K3DNA6 GWH 18 KG K3DN NO Description GWH 09 KF K3DNA E I 6E I Front Case Assy 2001237501 1 1 20012497 7 157 MAINTENANCE Super Free Match Service Manual 6 GuideLo
6. 0217 0 38 3B OGwkisbasyoBergg 1 _ uu MAINTENANCE Super Free Match E Service Manual Evaporator Assy 01002437 Wat 1 a 5 baimes 1 3 ws 1 m DihyBud 350 1 m 1 Aem M5N 3 10 2 10 z ete Box Cover 11 m 1 Electric Box Coverl 20122154 KNEE MEN NENNEN NN x ie Box Ansys 1 Comecting Cable me N me le MAINTENANCE amo 7 Super Free Match Service Manual 7 2 2 Duct type GFH 09 EA K3DNAIA I GFH 12 EA K3DNAIA I 33 dU Part list GFH 09 EA K3DNAIA I for CN210N0010 12 for CN210N0020 N D inti GFH 09 EA K3DNAIA I GFH 12 EA K3DNAIA I 0 escription 1 1 Arowafamasy 08856 1 2 Coeofiroda 008 1 1 s Plate ofthe Exit Tube Sub Assy 1 0496 1_ 9 Front votute casing 259525 2 26050 2 7 92 MAINTENANCE Super Free Match Service Manual Ambient Temperature Sensor 39000206 1 39000206
7. 114 TOL 114 7 2 Requirements of Power Circuit Cable rt 115 To Ground Requiere put 115 7 4 Precautions of Electrical Wiring 115 5 PECCAUTOMN Ay INOW 11S 116 7 6 Electrical Wiring Work for Outdoor Uni oet eri Ve e bees deca uie bes in sites 116 7 7 Electrical Wiring Work for BU 117 7 8 Electrical Wiring Work for Indoor 118 5 INSTALLATION OF DRAINAGE 120 Super Free Match Service Manual 8 1 Material Quality Requirements for Condensate Pipe 120 8 2 Key Points for Condensate Pipe Installation 120 9 Installation of Protective Layer on Connection 124 B 05 126 Testine Board Introduction x 126 LT C or 126 1 2 Instruction of Function and Data Section eene 126 PROCESS SO ear de t uti eie aqua dicus dun a uto pe 124 PAM copie DOOL 129 2 1 Check before Contacting Maintenance 130 2 2 taeda ad tat
8. yy iX Heat Only for the cooling and heating unit 6 IFEEL This function can be activated by pressing this button and canceled by another press When this function 15 on the I FEEL information will be sent out in 200ms after each operation on the controller and the remote controller will send the temperature information to the main controller every 10 minutes 7 HEALTH This function can be activated or deactivated by pressing this button After the unit is turned on the default is HEALTH ON 8 AIR AIR ON OFF can be selected by pressing this button 9 CLOCK The clock can be set up by pressing this button with the symbol displayed and blinking In such a case pressing or within 5 seconds can adjust the value If the button is pressed down for more than 2 seconds the value ten s place will increase by in every 0 5 seconds After that repressing this button and then symbol stops blinking which indicates the is made successfully After powered on the default value is 12 00 4 1 with displayed Once the symbol is displayed the current time is the Clock value otherwise it is the Timer value 10 TIMER ON ON will be displayed and blink for 5 seconds by pressing this button and soon adjust the time by pressing within 5 seconds Each press will make the time increased or decreased by 1 minute If the button is pressed down for mor
9. aa rri a Terminal black for indoor unit Name Printed circuit board DIP switch mE IEEE supply Terminal black for black for BU module Name Ground screw transmission line power supply Let the power cable and transmission line go through the rubber ring In order to protect the power cable 4 and transmission line from damaging by the hole the rubber ring cannot fall from that otherwise it may cause electrical shock or fire etc Connect the power cable of the BU module to the L N terminals with the sign of Power and as well as the ground screw 17 INSTALLATION Super Free Match Service Manual 5 Connect the transmission line of the BU module to the N 1 2 terminals with the sign of Outdoor unit BU 6 Ifthe transmission line need to be connected to the other BU module please connect the extra line to the N 1 2 terminals with the sign of BU 7 Connect the power cable of the indoor unit to the N 1 2 and 3 terminals with the sign of Indoor unit A B C D or E and as well as the ground screw 8 the power cable and transmission line firmly by cable fixing clip 9 Screw the electrical equipment plate Caution The transmission line and the power cable must be separated and separated with an interval of at least 2cm otherwise it may be result in communication problem Confirm the each cable connected to the terminal screw is exactly and se
10. e RI BU AP LI COOL PLASMA RECEIVER AND SWING JIS BOAR MO optional 036320490 Super Free Match Service Manual 2 Duct type 09 GFH 12 EA K3DNAIA I GFH 18 EA K3DNAIA I 21 GFH 24 EA K3DNAIA I MANUAL PANEL BOARD S a WH RD Ts BN YEGN FAN MOTOR 3 Cassette GKH 12 BA K3DNA2A I GKH 18 BA K3DNA2A JT Indoor Unit Dutdoor FAN CAPACITOR FAN MOTOR MAINTENANCE MANUAL PANEL 2 ENVIOEMENT TEMP SENSOR TR IN TR OUT CN2 7 v 2 TRANSFORMER CN18 S 7 PUMP cum E d LIQUID SWITCH NOTE AP3 is optinal aecesorry when and are connected at the same time AP2 is the default device Receiving Board TEMP ROOM TEMP SENSOR SENSOR 20K x L S 15 Punp Check CNI8 TR OUT CNIS b LIQUID SWITCH PUMP MOTOR TRANSFORMER is optional accessory If AP and are connected to the unit at the same time the default device will AP PE 7 Super Free Match Service Manual GKH 12 BA K3DNAIA I GKH 18 BA K3DNAIA I GKH 24 BA K3DNAIA I
11. E TT M niu E IL LOU it Cit ttt 1 Remove the code power code of the Note when removing the power cord please label the power cord and the terminals to avoid misconnecting next time Solder the joint of Solder the connecting pipe of connecting the compressor pipe of the b Pullout the compressor 2 connecting pipe connecting pipe m iliis of the compressor Note never let the flame contact any other component 157 MAINTENANCE Super Free Match Service Manual 3 Loose the fixed screws of the compressor base N 22 2 4 the compressor away from the seating 5 Fix the new compressor on the seating MAINTENANCE E E Unscrew the fixed screw of the compressor base Screw off the 77 xing screw of the compressor Remove and replace the compressor Note never let the flame contact any other component during the replacement Tighten the screws on the seating of the new compressor Tighten the screws on the base of the compressor 7 Super Free Match Service Manual Solder Solder connecting inlet and pipe to make them outlet to the pipeline Fine 6 Solder the pipeline with the connected suction and
12. Hanger metal Em ND unit side EM BEN unit side piping of circuit Drain hole outdoor unit side board equipment plate INSTALLATION Super Free Match Service Manual 5 3 Combinations for Outdoor and Indoor Units Sorts FXB3A K FXBSA K No of connectable BU modules for LM Min No of connectable indoor units 5 4 Selection of Installation Location The BU module is for indoor use The BU module must be installed on a firm and solid support which can withstand the weight of the module and the mounting surface must be horizontal plane The BU module can be chosen to install in the ceiling such as the ceiling of parlor corridor balcony storeroom and etc There is enough space for the installation and maintenance Avoid direct sunlight or other heat sources exist Do not install in location that 15 hot or humid for long periods of time Avoid the BU module installed in the bedroom and study where these places need to be quiet BU module cannot be installed in the place of inflammable and explosive materials and severe dust smoke and the other air pollution such as the kitchen There is enough space to install drainage pipe so that the condensed water be discharged Caution Installation at the following places might lead to the air conditioner malfunction If it 1 unavoidable please contact the appointed service center A pla
13. MAINTENANCE Super Free Match Service Manual D Long press Fuc key for more than 2s to enter the first level menu The first level menu includes control unit and display unit Press Enter key to enter the second level menu Press key to switch the menu Press Back key to the previous menu 2 Control unit operation When entering into the control unit The function section flashes the running code and the data section display the current value uninterrupted Set parameters Press Enter key to enter the second level menu and set parameters with the keys Now the function section displays the running code uninterrupted and the data section flashes the set parameters Finish setting After press Enter key to the end the function section will display the running code uninterrupted and the data section display the set parameters uninterrupted Back Press Back key to the previous menu and long press the Back key to exit the operation 3 Display unit operation When entering into the display unit The function section display running code uninterrupted and the data section display the current value uninterrupted are invalid in the operation 4 Ifno operation is performed within 1 min it will automatically return to the normal display 1 3 3 For example Set condensation temperature D
14. adu 130 PERS YEN IC SCEIDITOBH unciis 131 3 FLOW CHART OF TROUBLESHOOTING 134 3 1 Malfunction display High Pressure Protection 135 3 2 Malfunction display Low Pressure 135 3 3 Malfunction display Discharge temperature 137 3 4 Malfunction display Current 137 3 2 Maliunction display Communication aati 138 3 6 Malfunction display Indoor unit water full 139 3 7 Malfunction display Temperature sensor 139 3 8 Malfunction display High Low pressure sensor 140 4 POWER DISTRIBUTION 141 21 Diagram Power DIStPIDUHOD did eun 141 4 2 CVA CRAIN e Hess eue Id annoa 142 5 THE RESISTANCES OF COMMON TEMPERATURE SENSORS 151 M DM Renee eee 151 SUUM Eo m 152 69 o 153 6 DISASSEMBLY AND ASSEMBLY PROCEDURE OF MAIN PARTS 156 156 6 2 161 7 EXPLODED VIEWS AND PART
15. Check work mode of indoor unit is it properly set No Refer to nstruction Manual of indoor unit Check the stop valves are they open Completely open the valve Check the flow of the air inlet outlet is it not blocked No Remove the barrier panel of outdoor unit is it firmly closed Close the panel Measure the fan motor and signal input No Measure swing motor and signal input swing louver of indoor unit is it completely open indoor outdoor filter and heat Mai exchange fin is there filth Refer to Care and Maintenance Mainly check the inlet and outlet of main pipe connecting with each Refrigerant pipe is blocked indoor unit and capillary of indoor and outdoor units Replace the parts like filter capillary and so on 3 2 Malfunction display Low Pressure Protection 155 MAINTENANCE Super Free Match Service Manual Low pressure protection Check the pressure with a manometer is it really low Yes refrigerant in the system 15 it mode of indoor unit is it properly set Check stop valves are they completely panel of outdoor unit is it firmly closed Check the flow of the air inlet outlet is it not blocked Yes Check the fans of indoor unit and outdoo
16. iem m oe o 15e 2x9 iss m sms om __ 9806 252 164 _ 3 sim oss oss 9155 249 1m _ 3 s ose oss o ssm 26s 1m _ x 254 206 _ mme e sem 3m im MAINTENANCE a9 EJ Super Free Match Service Manual Temp Resistance Voltage Voltage Temp Resistance Voltage Voltage m 3V m 3V 4154 3389 2237 10 2498 400 2 640 4 6091 3 423 2 259 2 4308 4 022 2 655 90 4 4693 3 456 2 281 112 2 3654 4 044 2 669 4xus 34m 330 404 208 35m 14 3249 408 2 696 os Dose o2 an ue 3 7283 3 642 2 404 118 2 0148 4 162 2 747 3er 34 um 3259 sss 1903 279 sam 1882 Lm oam e ew Lm 3eei 3s ws 4 _ 257 38 ams 295 155 MAINTENANCE Super Free Match Service Manual 6 DISASSEMBLY AND ASSEMBLY PROCEDURE OF MAIN PARTS 6 1 Outdoor Unit 6 1 1 Disassembly and Assembly of the plates Remarks Prior to the assembly of the plates make sure the power supply is cut off Illustrations Operation Instructions 77 1 07 7722 Unscrew the fixed screws of t
17. PP PH RH ew pressure protection B B _ High pressure protection E _ High pressure switch protection Fash Bins d Capacitor charging ror ___ Fash times Ss AC omet protection E B Memory carderor Bb E _ Compressor demagnetizing protection HE Compressor desyoctronizing Hr Cowrsorpuslak Ur Ur _ Compressor phase circuit detection error Flash20times Uu Ul 151 MAINTENANCE Super Free Match m Service Manual Compressor discharge temperature Flash 23 times protection Lack of refrigerant jam protection of Lack of refrigerant jam protection or jm protection pue Frequency imitation for AC ame Hi _ Frequency limitation for IPM Flash 5 times EU EU temperature Frequency limitation for PFC Flash 6 times EU EU temperature Frequency limitation for compressor Flash 8 times LU overload Frequency limitation for compressor Flash 9 times discharge temperature limitation for low pressure 2E S S Frequency limitation for high pressure Flshll ms F Discharge temperat
18. 5 GREE CENTRAL AIR CONDITIONERS SUPER FREE MATCH SERIES SERVICE MANUAL S 1 410 50 7 201306 n L L X lt E p 4 p _ GREE ELECTRIC APPLIANCES INC OF ZHUHAI Contents PRODUC E E EE E E EE E N 2 2 ices acre ees 2 E BU MOGI ER 2 ES __ 6_6_ 6_6_6_6_ _ 3 toe 5 Outdoor _______ _ 5 22 Nomenclature ot BU Mod l 5 2 NOMeNC ature OF INGOOL UN eiis 5 r 6 EORR ERN 7 4 Product Outdoor a 7 4 2 Product Da ror Indoor 9 4 3 Product b pub raten tav abt haa 20 gt Temperate Range snos 21 D PIPING DIAGRAM dicitis ics Gates as 22 LUE 25 4 4 4 9 25 tI COO S 5 5 26 122 Heatin ue E 24 28 24 Control Func tion01 Outdoor
19. button time will increase decrease half an hour When holding or button 2s later the time will change quickly until to reach to your required time After that press TIMER button to confirm it The character of HOUR and OFF won t flash again Cancel TIMER OFF Press TIMER button again under TIMER OFF status At OFF status press this button once can set TIMER ON Please refer to TIMER off for detailed operation Cancel TIMER ON Press TIMER button again under TIMER ON status Note Time setting range 0 5 24 hours Time interval between two operations can t exceed 5s Otherwise remote controller will exit the setting status automatically 11 TURBO When pressing this button under cooling or heating mode air conditioner will enter into quick cooling or quick heating mode The character of TURBO 1s displayed on remote controller Press this button again to exit turbo function and the character of TURBO will be disappeared on remote controller 12 SLEEP Press this button under cooling heating mode can start up sleep function C icon will be displayed on remote controller Press this button again to cancel sleep function C on remote controller will be Super Free Match Service Manual displayed 13 LIGHT Press LIGHT button to turn on the display s light and press this button again to turn off the display s light If the light is turned Y is displayed If the
20. 17171 7107 Airtowert 1 1 1 3 _ dehy axite Bush 109908 Em MAINTENANCE Super Free Match Service Manual ___ 1 Russer Pug Water Tay 1 1 2615202 1 1 15 OGasketsubassy of Bearing 7651205102 1 6 1 _ CesFowfm 1 RemoeComele 1 1 Temperature Sensor 390059 1 3990099 1 Ambient Temperature Sensor 390000453 1 3000003 1 Connecting Cable 4002052817 0 0 5 Evaporator Support 29299 1 1 Evaporator Assy 1 1 _ Wall Mounting Fame osos 1 1 1 7 pd 9 m m ___ isons 1 1 Pipe Clamp 25884 1 1 Drainage hose 0830146 1 step Motor 1 1 Display Board 1 30689 1 9 Guide Lowe 31 Y _ 39 Aweme 1536 1 1084206 1 3 2000160 1 32 Terminal Board 42011233 42011233 3 Capacitor cast 330099 1 3000011 Cover 2012205 1 1 _ 1 O 5 Ma
21. An all pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring 7 3 Ground Requirements Theair conditioner is classified into the Class I appliances so its ground ways must be reliable The ground wire must be fixed on the screw hole with the sign as the right figure QD The yellow green wire of the air conditioner is the ground wire and must be fixed by the tapping screw And it cannot be used for other purpose or cut off Otherwise it will cause the hazard of electric shock The reliable ground terminal should be provided and the ground wire cannot be connected to any of the following places a Water pipe b Coal gas pipe c Sewage pipe d Lightning rod e Telephone line f Other unreliable places considered by a professional 7 4 Precautions of Electrical Wiring Work The ground connection should be reliable and the ground wire should be connected to the dedicated device of the building by the professional 5 INSTALLATION Super Free Match Service Manual The electric installation should be carried out the professional as instructed by the local laws regulations and also this manual The air switch coupled with the leakage current protection switch must be equipped in the circuits which is of enough capacity and of both magnetic and thermal tripping functions in case of the short circuit and overload The p
22. eben 174 sq 174 T2 15 LU I DE 177 fro ner 211 7 Super Free Match Service Manual PRODUCT Super Free Match Service Manual PRODUCT 1 MODELS LIST 1 1 Outdoor Unit Capacity Capacit Power su Power supply pply Model Product code Cooling Heating Appearance ant Ph V Hz KW KW GWHD 48S NM CN860W0110 14 0 16 0 3CO 410 3 380 415 50 GWHD 56S NM 266 CN860W0120 16 0 18 0 1 2 BU Module Number of connectable Power supply Model Product code E AN AN units Refrigerant Appearance PhVHz V Hz R410A 1 220 240 50 FXB5A K LN01300220 Super Free Match Service Manual 1 3 Indoor Unit 1 3 1 Wall mounted type gt Hansol Capacity Power supply Product code Cooling Hz a gt U cool Capacity 00 Power supply Model Product code Cooling Heating Appearance 2 kW GWH 09 UA K3DNAIB I CB204N02700 2 6 8 gt Cozy Capacity Power Power supply Refrige Model Product code Cooling Heating Appearance rant Ph V Hz kW GWH 09 MA K3DNA3E I CB171N08501 2 6 8 gt Change Capacity 00 Power Power supply Refrige Model Product code Cooling Heating Appearance rant Ph V Hz kW E R4
23. le 4 1C 6 Wall mounted 09 INSTALLATION Super Free Match Service Manual uo nu 3 3 tess ass 3 93 ac ws The total length of the liquid pipes 20 10 10 5 5 5 5 5 5 70 Thus the total length is over than 30m so the air conditioner needs to add refrigerant Additional refrigerant charge 2 the Liquid Pipe Length of 06 35 X 0 022kg m the Liquid Pipe Length of 59 52 X 0 054kg m 1 47 kg 5 5 5 5 5 5 m X 0 022kg m 20 10 10 m X 0 054kg m 1 47 kg 1 35 kg 4 Additional refrigerant charge record Total length m Additional refrigerant charge kg 6 11 3 Procedures for adding refrigerant r 5 Pressure vacuum gauge E O Name Outdoor unit Service port Liquid side stop valve Gas side stop valve 1 When the liquid and gas stop valves have not been opened the system is under the vacuum 1 Refer to the left of the figure connect the R410A tank to the system 2 Turn on the R410A tank and the Hi knob charge the R410A refrigerant into the system from the liquid side stop valve The Lo knob should be closed completely 8 Turn off the R410A tank and the Hi knob immediately when the adding refrigerant is enough 4 Turn on the liquid and gas side stop valves in an anticlockwise dire
24. 1 082006 71 WhsiePheAsy onono 1 1 oone 1 3031009 1 3os100491 3080091 I 40 Pump asy 0050702 1 1 osama 1 DisplayBoad 3096317 1 MAINTENANCE 20 7 Super Free Match Service Manual 7 2 4 Floor ceiling type 09 12 45 18 e s erue wees wee 19 Part list GTH 09 BA K3DNAIA I for CN610N0010 GTH 12 BA K3DNA1A I for CN610N0020 4 Rotating shat 326x950 4 2699950 4 s 1 nens 1 7 205 MAINTENANCE Super Free Match Service Manual 1 1 9 1 710 Front volute casing 4 4 Rarsdpuems 1 1 102530 4 10530 4 Main Board Ames 1 MAINTENANCE 7 Super Free Match Service Manual GTH 18 BA K3DNAIA I gll 34 cu 33 qo 31 30 29 28 127 126 25 2l Part list GTH 18 BA K3DNAIA I for CN610N0030 Qty 2 tower Camp 2 3 Gela NO Description 4 2690 4 3 Front Connecting Pte 6 Arme 7 205 MAINTENANCE Super Free Match Service Manual 8 z
25. EVAPORATOR 4 Recelving Board ow PIPE TEMP ROOM TEMP SWING MOTOR 5 SENSOR SENSOR L 20K x1 6 NE 480 5WH 17 8 SWING X6 X1 AC N TR IN TR DUT Pump Check PUMP Swing Check CN7 CNIS CNI8 CNIS aa TC BU RD lt gt 2 LIQUID New TRANSFORMER SWITCH PUMP MOTOR is accessor C Ive If ond AP3 ore connected to E the unit at the same time the default device will FAN MOTOR 4 Floor ceiling 09 GTH 12 BA K3DNAIA I GTH 18 BA K3DNAIA I GTH 24 BA K3DNAIA I MANUAL PANEL 2 ROOM TEMP SWING SENSOR SENSOR 52 lt L i 5 Ne 4 4 3 410 TR IN Punp Check DN CHE O TC Oc WH COMPONENT POSITION MAP ABI TRANSFORMER L 1 1 NOTE APe is optional accesso pr and are connect unit at the same time the default FAN 4j AHN the capacrTor gt BL device will be Are FAN MOTOR PE MAINTENANCE Super Free Match Service Manual 5 Console GEH 09 AA K3DNAIC I GEH 12 AA K3DNA1C I GEH 18 AA K3DNAIC I ROOM TEMP TUBE TEMP RECE
26. m m 40 852 852 798 609 Notes a The rated cooling capacity data is measured under the following work condition Indoor Temperature is 27 C DB 19 C WB Outdoor Temperature is 35 C DB The rated heating capacity data is measured under the following work condition Indoor Temperature is 20 C DB Outdoor Temperature is 7 6 b The data will change with the change of products Refer to those parameters listed on nameplate Noise was tested semi silenced room so the actual noise value will be a little higher for change of ambient Super Free Match Service Manual gt Change Model GWH 07 KF K GWH 09 KF K GWH 12 KF K GWH 18 KG K ode 3DNA6E I 3DNAGE I God ing in I Power EIN V Ph Hz 220 240 1 50 220 240 1 50 220 240 1 50 220 240 1 50 Motor power input 3 m Air flow volume Sound pressure level dB A 40 38 30 24 41 38 30 24 42 39 3 1 25 45 40 37 32 SH H M L oon _ Fan motor Running a 3 8 9 52mm 3 8 9 52mm 3 8 9 52 1 2 512 7mm Connecting 1 4 6 35mm 1 4 35 1 4 6 35mm 1 4 6 35 pipe Flare Flare Flare Flare Connection method Connection Connection Drain pipe m 15 i5 15 a5 Outline 770 201 283 770 201 283 770 201 283 865 215 305 dimension Package WxDxH mm 847x264x357 847x264x357 847x264x357 948x298x395
27. FH 93 INSTALLATION Super Free Match Service Manual 4 5 Installation of Console Type 4 5 1 4 5 2 4 5 3 Installation Location and Matters Needing Attention The installation of air conditioner unit must be accordance with national and local safety codes Installation quality will directly affect the normal use of air conditioner unit The user is prohibited from installation by himself Please contact your dealer after buying this machine Professional installation workers will provide installation and test services according to installation manual Do not connect to power until all installation work 15 completed Selection of installation location Such a place where cool air can be distributed throughout the room Such a place where condensation water is easily drained out Such a place that can handle the weight of indoor unit Such a place which has easy access for maintenance The appliance shall not be installed in the laundry There are 2 styles of installation Ceiling type Floor type Each type is similar to the other as follows The indoor unit should be sited in a place where 1 2 3 4 5 6 7 8 4 5 4 4 5 5 INSTALLATION the restrictions on installation specified in the indoor unit installation drawings met Both air intake and exhaust have clear paths met The unit is not in the path of direct sunlight
28. Heft SHELD SAVE E HEATER BLOW CO Enter cancel A Fan Mode O O O O 0 O Function Timer On Off LCD of the Wired Controller DELS Ax AUTO TURBO elo SHELD MEMORY MASTER BLOW CO2 QUIET 78 9 101112 1314 15 16 17 1819 A Running modes of the indoor unit Cooling Dry Fan Heating and Auto B osemetesstdemderwk 0 B High middle low or auto fan speed of indoor unit Shield functions buttons temperature On Off Mode or Save is shielded or Save is shielded by the remote monitor Turbo function Memory function The indoor unit resumes the original setting state after power failure and then power recovery 7 Super Free Match Service Manual Master wired controller this function is yet unavailable for this unit It blinks under on state of the unit without operation of any button SAVE Energy saving function this function is yet unavailable for this unit Ambient preset temperature value Electric auxiliary heating function this function 15 yet unavailable for this unit Blow function cet function two types quiet and auto quiet this function is yet unavailable for this DE It will be displayed under the debugging mode 3 1 2 Buttons Buttons on the Wired Controller 3 4 EN 1 Function selection and cancellati
29. 28 22 2 29 PANE Y Go B10 OE 30 2 4 Control Function of Indoor 31 2 REMOTECONIROLLER 5 4 eth 34 3 1 Wired Remote Controller 25252 mers ERSTE DII SEIS ee 34 3 2 Wireless Remote Controller 39 3 3 Wireless Remote Controller YAATFB1 43 3 4 Wireless Remote Controller 400 0 0 2 6 10 enne 47 3 5 Wireless Remote Controller 2 CXFAN sscccsccccsssccssseessscccessecesssesssscccsseeesesees 53 A Smart Conttollet CB50 24 B e temet tiia 58 ar ener Introductio cosi 58 4 2 Communication ivt eie boream ai buda o iwadacadadesies 59 LE C C EN 59 2 4 BUTOR vote peso deabus __ __ _6_ _ 6 6_6_ ____ ___ _ aud 60 MINS MIO e M 63 1 PRECAUTIONS FOR INSTALLATION 63 Lely Precautions Tor 63 1 2 Kev OF ATO iacere 65 Super Free Match Service Manual 2 FLOWCHARTOFIN
30. Front panel L Remove 4 screws Super Free Match Service Manual 150 15cm below from the floor Remove front grille Open the front panel 95 INSTALLATION Super Free Match Service Manual 3 For Side Piping Remove the pillars 1 Remove the 7screws 2 Remove the upper casing 2 tabs 8 Remove the left and right casings 2 tabs on each side 4 Remove the slit portions on the bottom frame and casings using nippers 5 Return by following the steps in reverse order 3 gt 2 gt 1 4 Installation 3 Side casings Iam Deui ILE x He THESIS IR d e f 3 Side casings Remove the pillar Casing Remove the pillar Botiom frame Is Secure using 6 screws for floor installations Do not forget to secure to the rear wall For wall installations secure the mounting plate using 5 screws and the indoor unit using 4 screws The mounting plate should be installed on a wall which can support the weight of the indoor unit Temporarily secure the mounting plate to the wall make sure that the panel is completely level and mark the boring points on the wall Secure the mounting plate to the wall with screws Floor Installation RT ri
31. Wig RD NX j E 23824100015 A s MAINTENANCE Super Free Match Service Manual 4 2 2 Indoor unit 1 Wall mounted type Hansol GWH 07 TA K3DNAITE I GWH 09 TA K3DNAIE I GWH 12 TB K3DNAIE I GWH 18 TC K3DNAIE I ROOM TEMP TUBE TEMP RECEIVER AND FAN MOTOR WARNIN SENSOR SENSOR Um BOARD COOL PLASMA Please don t touch any electronic component or GENERATOR terminal when the machine 2 is running stopping has been powered off E less than 3 minutes to prevent electric shock RON DISP DCJMOTOR rag AP mum TERME e Y YEGN CABLE EG SA PRINTED CIRCUIT BOARD LEFT RIGHT UP DONN STEPPING MOTOR STEPPING MOTOR STEPPING MOTOR U Cool ROOM TEMP TUBE TEMP RECEIVER AND SENSOR SENSOR DISPLAY BOARD FAN MOTOR ROOM TUBE DISP DISP PRINTED CIRCUIT BOARD 2 TERMINAL BLOCK STEPPING STEPPING MOTOR MOTOR 7 2 MAINTENANCE Super Free Match Service Manual Cozy GWH 07 MA K3DNA3E I GWH 09 MA K3DNAS3E I GWH 12 MB K3DNA3E I GWH 18 MC K3DNA3E I TUBE ROOM TEM SENSOR TEM SENSOR CAP JUMP DISPLDISP2 SWING UD HEALTH N HEALTH L 7 RECEIVER AND SWNG pe DISPLAY BOARD MOTOR ae NOTE The parts with broken line is applicable to the model
32. button to adjust swing angle Atter selecting fan mode air conditioner operates only under fan mode All mode indicators on indoor 51 unit is OFF Press FAN button can adjust fan speed Press 7 button and 1 button to adjust swing angle After selecting heat mode air conditioner operates under heat mode Heat indicator Le on indoor unit is ON You can press or button to adjust set temperature Press FAN button to adjust A fan speed Press button and 1 button to adjust swing angle Cooling only unit can t receive the signal for heating mode Note For preventing cold wind after starting up heating mode indoor fan will blow fan afterdelaying 1 5min Details time is decided by indoor ambient temperature Temperature setting range on remote controller 16 30 C Fan speed setting range auto low speed medium speed and high speed After each pressing of or button it can increase or decrease set temperature 1 Hold or button 2s later set temperature on remote controller will change quickly After reaching to your required time loosen the button Temperature indicator on indoor unit will also change accordingly Temperature can t be adjusted under auto mode Under TIMER ON TIMER OFF or Clock setting you can press or button to adjust time Refer to TIMER button for details 4 FAN Press this button Auto Low Medium High
33. E isk ri T 45 a VICO Wi TEES Na 6screws INSTALLATION Wall Installation VA EA WI a o fini x _ A 1 fi m I Y 3 NW T EN 123 t eu 12 rap sl s es i Molding i Super Free Match Service Manual Once refrigerant piping and drain piping connections are complete fill in the gap of the through hole with putty A gap can lead to condensation on the refrigerant pipe and drain pipe and the entry of insects into the pipes Attach the front panel and front grille in their original positions once all connections are complete 4 5 8 Connecting the drain hose 1 Usecommercial regid polyvinyl chloride pipe general VP 20 pipe outer diameter 26mm inner diameter 20mm for the drain pipe 2 drain hose outer diameter 18mm at connecting end 220mm long is supplied with the indoor unit Prepare the drain pipe picture below position 3 The drain pipe should be inclined downward so that water will flow smoothly without any accumulation Should not be trap 4 Insert the drain hose to this depth so it won t be pulled out of the drain pipe 5 Ins
34. _ 37 3x4 1 3mm 1 1 1 3 omen 1 MAINTENANCE 7 Super Free Match Service Manual 12 18 24 Part list GKH 12 BA K3DNA 1A I for CN510N0010 GKH 18 BA K3DNA1A I for CN510N0020 GKH 24 BA K3DNA 1 A I for CN510N0030 201 MAINTENANCE Super Free Match Service Manual GKH 12 BA K3 GKH 18 BA K3 GKH 24 BA K3 1 1 oes 1 ____ 1 1 1 7877 Botiom Foam Assy 5000720 1 1 71 9 MotorGasket 4 18 Comes Bort Any 1 1_ Filter Sub Assy 11120011 11120011 11120012 1 718777 osse 1 1 1 WaterTray Assy 1 2 1 1 3i Evaporator Support Assy 01072704 2 2 01072703 2 3 MagneticRing 49010104 1 4990004 49104 Lx waer enn 1 oen 34 WaerumAsy 0130780 1 1 085782 1 3s Pump Suppor 1 1 1 3 WaeleeiSwi 1 1 1 1
35. replace it Connect the water pipe to the water pump and then screw the screws around it Place the drain pan and the bracket of the filtering screen at the original position and then screw the screws around them with a screwdriver Place the front panel assembly at the original place and screw the screws around it Put the front panel at the original place and press the locks at both ends to secure it M M MAINTENANCE Super Free Match Service Manual 6 2 4 Four way cassette type Removal and Assembly of Fan Motor Remark Prior to the assembly of the motor make sure the power supply is cut off Illustrations Operation Instructions Unscrew the screws a 1 Unscrew the fixed Unscrew the fixed screws of the water tray screws of the water tray 2 Remove the water tray ter sy Remove the water tray 3 Unscrew the fixed Unscrew the fixed bolts of bolts of the fan LIS the fan with spanner MAINTENANCE E Super Free Match Service Manual Remove the fan Remove the fan 4 Remove the fan gt Loosen the bolts Loosen the fixed bolts of the fan motor 5 Loosen the fixed bolts of the fan motor Remove the fan motor Remove the motor and e O O gt oO replace it replace it MAINTENANCE Super Free Match Service Manual 7 Screw the fixed bolts of the motor 8 Mount the fan
36. z AE expansion axpans expansion mire EA wae 8 222410021 7 is 7 149 MAINTENANCE MAINTENANCE Super Free Match Service Manual FXBSA K XTE 2 peop ea Indoor A G Indoor unit Indoor unit Indoor unit E Eketch of Electric Parts le iT EX Electronic axpare Lon coll 1 Electronic exczans pell B 2D EOR 8 E Indoor SUE RTOE ATIOE Eleciranic expans lon Valve call D Falme coll D walwe coll E unit gaz pipe tube mnor unit C gus pigs tubs unit gaz pigs tube zcnznr wy BU QUEE o 2 12 XT BE en z WEE ra xs W22 BN z unit liquid pipe tube zc zor unit B suid pips tube scneor unit liquid pipe tube memor r unit D gaz pipe tube zcnzor unit liquid pige tube zc zor NIS sdear unit liquid tube zznznr E M 3U module 61434100054 7 Super Free Match Service Manual 5 THE RESISTANCES OF COMMON TEMPERATURE SENSORS 5 1 15 Resistance Voltage Voltage Temp Resistance Voltage Voltage ma
37. 1 Temperature Sensor ___ 390001986 1 71 3 1 1 MAINTENANCE amo Super Free Match Service Manual GFH 18 EA K3DNAIA I J al 13 c9 Ef E cl Part list GFH 18 EA K3DNA1A I for CN210N0030 NO GFH 18 EA K3DNAIA I escription i E outlet frame assy 01865217 Water Tray Assy 01285333 s tower Cover 08 1 sitet sige Pte Assy 1 Pht oFthe Exit Tabe orsa T s Frontvotute 7 195 MAINTENANCE Super Free Match Service Manual Renten o Pf Bottom Cover Pie O osa 1 1 a5 16 osoo E 1 04 1 19 Temperature 29 Ambient Temperature Sensor 399926 1 CwePeoff efm m 190918 m O a 4 1 1 3 x _______ 1 m fan 3 5 1 3 Ria Side Pate Assy 08 1 3 10 1999401 1 4 T A4MEX4 1 3s Remmote Contre 30401 5 03 N A
38. 5 FanMounting ate 1 O o 3 x Water WaeLedSweh xin 3s 1 Ale NIe MAINTENANCE E E Super Free Match Service Manual 7 2 3 Cassette type GKH 12 BA K3DNA2A I GKH 18 BA K3DNA2A I 7 19 MAINTENANCE Super Free Match E Service Manual Part list GKH 12 BA K3DNA2A I for CN510N0040 GKH 18 BA K3DNA2A I for CN510N0050 5 771 went 1 Front Side Plate 01302741 01302741 1 Trish Bae assy 1 1 4 1 1 _ 5 Pomp Dring 1 emm 1 s Body stalling Suppor 01332708 4 4 11 camem Water Level Switch 450127011 450127011 779 me eme 3 a 10 3900019826 1 1 1 1 13 ambient Temperature Sensor 3900019813 1 T _ 14 Filter Sub Assy 11120011 1 11120011 1 7715 1 M8 1 16 _______ 1 71 7 Bepmtrsups oona 1 1 Evaporator Oo 1 002300 1 25 Go 26 3300006 1 3300006
39. Note never let the discharge ports of flame contact any other the compressor component E Refer to marked reconnect the power cords of cord the compressor Connect the power mW Tighten the fixing screw of the power E 7 Reconnect the power cords cord Note mark the color of the power cord and corresponding terminal Check if the pipe is M well connected 9 Check and 5 Check if the parts screw back the 6 wire well connected plates If there 15 no uem problem fix the n 4 159 MAINTENANCE Super Free Match Service Manual 6 1 3 Disassembly and Assembly of 4 way valve Remarks Prior to the assembly of the compressor make sure there is no refrigerant in the pipeline and the power supply is cut off Illustrations Operation Instructions Remove the magnet coil a Unscrew the fixed 22 As of 4 way screws of the magnet Remove the magnet AME S p Ter 7 J coil coil of the 4 way valve 5 H b Remove the magnet iiia coil JA T Solder off the four joints aS N Solder off the connecting pipes Note never let the flame 2 Disconnect the 4 way lt 3 TEE valve and the m connecting pipe contact any other e mi
40. The character of X FAN will disappear Note Atter starting up X FAN function when turning off the unit indoor fan will continue to operate for a while at low speed to dry the residual water inside the indoor unit Super Free Match Service Manual When the unit operates under X FAN mode press X FAN button can turn off X FAN function Indoor fan stops operation immediately 9 TEMP Press this button can see indoor set temperature indoor ambient temperature or outdoor ambient temperature on indoor unit s display Temperature 15 set circularly by remote controller as below no display 2 When selecting Q by remote controller or no display temperature indicator on indoor unit displays set temperature When selecting n by remote controller temperature indicator on indoor unit displays indoor ambient temperature 1 When selecting by remote controller temperature indicator on indoor unit displays outdoor ambient temperature Note Outdoor ambient temperature display may can t be selected for some models When indoor unit receives m a 7 signal it displays indoor set temperature Only for the model whose indoor unit has dual 8 display 10 TIMER At ON status press this button once can set TIMER OFF The character of HOUR and OFF will flash Press or button within 5s can adjust the time of TIMER ON After each pressing of
41. The unit is away from the source of heat or steam There is no source of machine oil vapour this may shorten indoor unit life Cool warm air 15 circulated throughout the room The unit is away from electronic ignition type fluorwscent lamps inverter or rapid stert type as they may shorten the remote controller range The unit is at least 1 metre away from any television or radio set unit may cause interference with the picture or sound Cautions foe installation where air conditioner troubles liable to occur Where there 15 toomuch of oil area Where it is acid base area Where there is irregular electrical supply Outline Dimension Drawings of the Indoor Unit Floor Installation Wall Installation 7 10 ERI E Se __ pS spp SD ht 3 IR 69 11 T S 30 7 lind 22 7 7 T LE 730 4 5 6 Installation and Servicing Space 2 INSTALLATION PAPER PLANK Installation of the Indoor Unit Preparation Open the front panel remove the 4 screws and dismount the front grille while pulling it forward Follow the arrows to disengage the clasps on the front case to remove it Follow the procedure below when removing the slit portions For Moldings Remove the pillars Remove the slit portions on the bottom frame using nippers Tac 150
42. please check the piping and wiring ensure they are correct to avoid water leakage refrigerant leakage electric shock or fire etc Ground connection connect to the ground reliably The ground wire should be connected to the appropriative grounding device of the building If the appropriative grounding device is not available please ask a professional to install Never connect the ground wire to gas pipe water pipe lightning rod telephone line or other unreliable places considered by a professional It must install an earth leakage breaker Otherwise it maybe cause electric shocks or fire etc Install the air conditioner the power wire and transmission line must be more than one meter away from televisions or radios which can emit electromagnetic waves to prevent image interference or noise Otherwise the unit maybe cannot work The drain pipe should be installed as instructed in the manual to guarantee the proper drainage meanwhile it should be insulated to prevent condensing otherwise the improper installation would cause water leakage and then wet the household wares in the room Be sure to shut off the power supply when you do not use the air conditioner for a long time Otherwise the dusts may accumulate it which may cause overheating or fire hazards Never standing on the outdoor unit or place objects on it Person or objects falling from the unit may cause injury The air conditioner is not support to install in the circu
43. then the unit will go to the setting status of the Defrosting Mode 1 5 it is turned on through the wired controller Then once the indoor unit receives this signal it will soon send it to the outdoor unit In contract if H1 is displayed the unit will go the setting status of the Defrosting Mode 2 and the indoor unit also will send this signal to the outdoor unit as soon as it receives it On condition that the unit is off it 15 available to switch over the Defrosting Mode 1 and Defrosting Mode 2 by pressing the MODE and BLOW buttons simultaneously 9 Turbo As soon as the controller receives the Turbo instruction the fan of the indoor unit will run at the high speed 10 Blow Blow Function It is a function to automatically blow off the moist inside the exchanger of the indoor unit to prevent mould growing after the unit 1s shut off a On condition that this function is activated when the On Off press button is operated the fan of the indoor unit will still run for ten minutes with the symbol BLOW displayed At this time the fan will stop as this function is deactivated b This function 15 unavailable under the AUTO FAN and HEAT modes Super Free Match Service Manual 3 REMOTE CONTROLLER 3 1 Wired Remote Controller 3 1 1 Wired Controller XK19 Z63351L It is designed for the cassette type duct type and floor ceiling type indoor units Outside View of the Wired Controller
44. through Yes Check the power of the unit 15 it turn on Yes address of BU modules the ame system repeated Yes any equipment which can emit electromagnetic waves near the unit Yes MAINTENANCE EE NO NO NO NO NO The transimission line is too long Check the orientation of plug and socet Check the orientation of plug and socet Replace the transimission line Turn on the power Change the repeated address codes Remove the equipments 1 meter away from the unit Refer to the recommended transmission line 7 Super Free Match Service Manual 3 6 Malfunction display Indoor unit water full protection Water full protection Yes Check the Is the water overflow switch is it ok Yes Check the water drainage pump is it works Check the pump 15 it ok Yes Voltage of liquid level Voltage of water drainage No Maintain the liquid level switch Replace the mainboard of the indoor unit No Maintain the cables of water drainage pump Replace the mainboard of the indoor unit water drainage pipe jammed water flows smoothly Adjust the water drainage pipe Yes Clear the water drainage pipe 3 7 Malfunction
45. 51 3 076 2 030 57 5 519 3 919 2 586 x m 3m 209 29 us 3m 268 3 1o 25 9s 405 296 oe e 288 9 803 3 3959 2 215 4 443 4 091 2 700 35 ms m sex 5 34 22 3 2 5 p oss 7 745 3 604 2 379 3 603 4 237 2 796 L 5 3s 3 e 3e es 2m s 7r 360 24 334 4 295 _ 6 648 3 753 2 477 3 144 4 321 2 852 5 3 50 pad Resistance Voltage Voltage m Resistance Voltage Voltage ws wm eme a Ses 35 999 2593 ov 0 0 129 m sew 0 6 205 ae o o Q9 155 MAINTENANCE Super Free Match Service Manual pens Resistance Voltage Voltage Resistance Voltage Voltage 14542 42 gt 322 242 21 21425 1590 1 1 050 mam mm Wk mum AM mE s o3 146b s we 169 19 125 _ s was oo s 1638 isor 129 _ 4 se ese 06 mss 1400 ome em em s nme 1 73 896 0 596 0 393 59 12 617 2 211 1 459 ee
46. 9 52 3 8 9 52 1 2 12 7mm 5 8 15 9 Connectin ias 1 4 6 35 1 4 6 35 1 4 6 35 3 8 9 52 pipe Connection method Flare Connection Flare Connection Flare Connection Flare Connection External Drain pipe Thickness Outli PLIN snas men dimension Package WxDxH mm 1343 823 315 1343 823 315 1343 823 315 1343 823 315 dimension Net Weight Gross weight 40 50 40 50 40 50 45 54 Loading quantity Notes a The rated cooling capacity data is measured under the following work condition Indoor Temperature is 27 C DB 19 C WB Outdoor Temperature is 35 C DB The rated heating capacity data is measured under the following work condition Indoor Temperature is 20 C DB Outdoor Temperature is 7 6 C WB b The data will change with the change of products Refer to those parameters listed on nameplate Noise was tested semi silenced room so the actual noise value will be a little higher for change of ambient Super Free Match Service Manual 4 2 5 Console type GEH 09 AA K3DNA1 GEH 12 AA K3DNAI1 GEH 18 AA K3DNAI Model Heat pump en KW 2 6 3 5 5 3 Wei Kw 28 38 Power supply Ph Hz 220 240 1 50 220 240 1 50 220 240 1 50 flow volume Sound pressure level dB A 40 38 36 33 30 27 25 42 40 38 37 35 32 25 48 46 44 4 1 37 35 32 De Fan
47. It is deemed acceptable if the pressure will not rise Add refrigerant according to the volume as specified on the Add refrigerant engineering drawing Remarks Leakage detection under pressure a Described above are general working procedures The procedures might vary with the site conditions b For detailed installation rules please see the description in each chapter INSTALLATION 6 Super Free Match Service Manual 2 FLOW CHART OF INSTALLATION Design kicking off Material selection Inspection of site installation position 4 4 Installation of indoor unit Installation of outdoor unit Installation of BU module Installation of Connection of Connection of Connection of Connection of Connection of remote transmission transmission power cables power cables power cables controller line line Installation of piping adapter Assign the address Installation of refrigerant pipes i Leakage test i Vacuum the system through the gas and liquid valves Refrigerant charging Open valves Installation of drainage pipes Thermal insulation of connection pipes and drainage pipes 4 Test
48. Long press Fuc key for more than 2s to enter the first level menu the function section flashes code and the data section 15 blank Press Enter key to enter the second level menu the function section flashes AE code and the data section display the current parameters Switch with the Fuc key to set condensation temperature the function section flashes code and the data section display the current parameters Press Enter key the function section display code uninterrupted and the data section flashes the current parameters 069 Switch with the to the target value and then press Enter key the function section display AC code uninterrupted and the data section flashes the new parameters uninterrupted 1 3 4 The meaning of running code MAINTENANCE E Super Free Match Service Manual Function Sorts Data section Remarks Use the n keys to switch L and H Set evaporation Default If you want to get a higher cooling temperature capacity select L else select H Use the keys to switch L and Set condensation Default If you want to get a higher heating temperature capacity select else select L The current parameter Use the keys to switch ON OF set defrosting mode The current parameter ON represents that the unit is running
49. Manual Consult the user and builder for more details If the strength of the ceiling is not strong enough a beam made of angle iron can be used and then fix the unit on it If the indoor unit is not installed in the air conditioning area please use sponge around the unit to prevent condensing The thickness of the sponge depends on the actual installation environment 22 1 Horizontality Check of the Indoor Unit After the installation of the indoor unit its horizontality must be checked to make sure the unit keep horizontal fore and aft and keep an inclination of 5 toward the drain pipe right and left Horizontality Check Device 4 2 8 Installation of the Air Supply Duct 1 Installation of the Rectangular Air Supply Duct 2 Installation of Round Air Duct Plenum Box 179 INSTALLATION Super Free Match Service Manual 6 _ Installation Steps of the Round Air Supply Duct Preinstall the outlet of the round duct on the transition duct and then fix it by the self tapping screw Place the transition duct to the air outlet of the unit and fix it with rivet Connect the outlet to the duct and then tighten them with tape Other installation details are not covered herein CAUTION The maximum length of the duct means the maximum length
50. am 15 is ss Outli 806x209x292 806x209x292 866x209x292 1018x230x319 dimension Package WxDxH mm 888x297x377 888x297x377 945x297x377 1097x397x340 dimension wef a poa Notes a The rated cooling capacity data is measured under the following work condition Indoor Temperature is 27 C DB 19 C WB Outdoor Temperature is 35 The rated heating capacity data is measured under the following work condition Indoor Temperature is 20 C DB Outdoor Temperature is 7 6 b The data will change with the change of products Refer to those parameters listed on nameplate Noise was tested in semi silenced room so actual noise value will be a little higher for change of ambient Super Free Match Service Manual gt U cool 3DNAIB I 3DNAIB I 3DNAIB I 3DNAIB I Mewpweipu kw om _ Air flow volume Sound pressure level dB A oe m oe mE SH H MH M ML L SL 26 24 26 25 27 26 31 28 Fan motor Running 0 136 0 136 S EN inch 3 8 99 52mm 3 8 09 52mm 3 8 9 52mm 1 2 12 7 Connecting 1 4 6 35 1 4 35 1 4 6 35 1 4 6 35 pipe Flare Flare Flare Flare Connection method Connection Connection ER AM Drain pipe ts Outline 860 153 299 860x153x299 896x159x320 998x178x340 dimension Package WxDxH mm 944 247 386 944 247 386 973 255 403 1083 283 4
51. day Shield It displays the shielded status ALL TEMP MODE and ON OFF Weekly timer It displays the timing period unit 0 5 hour which will circulate every week Set temperature It displays the set temperature indoor unit code 01 16 and symbols of Celsius Indoor unit code and Fahrenheit scale It displays CENTER under the centralized control mode and no display under 7 Control mode the single control mode Ambient temperature It displays the ambient temperature serial port as well as symbols of Celsius and Serial port Fahrenheit scale Numbers indicate the indoor unit codes which will be displayed when the Indoor unit code mM corresponding indoor unit is online LI indicates the on off status of the indoor on unit that is when it 1s bright it means the unit 15 when it is gone out it means the unit is Off It displays the error codes when some error s arises and also CHILD LOCK 10 Error Child lock mE when this function 15 activated 4 4 Buttons 4 4 1 Outline of Buttons off status 7 Super Free Match Service Manual 4 4 2 Introduction to the Function of Buttons 1 Under the single centralized control status It is used to set the running temperature of the indoor unit with max 30 C and min 16 C 2 Under the timing setting status It is used to set the timing period with max 24 hours No EN 5 and mi
52. dimension Loading quantity Notes a The rated cooling capacity data is measured under the following work condition Indoor Temperature is 27 DB 19 C WB Outdoor Temperature is 35 The rated heating capacity data is measured under the following work condition Indoor Temperature is 20 C DB Outdoor Temperature is 7 6 b The data will change with the change of products Refer to those parameters listed on nameplate c Noise was tested in semi silenced room so the actual noise value will be a little higher for change of ambient Super Free Match Service Manual gt Viola Capacity ae mem uw 3 7 2 lt lt Fan motor Connection method Flare Connection Flare Connection Drain pipe Super Free Match Service Manual Capacity ee ee Power supply V Ph Hz 220 240 1 50 220 240 1 50 220 240 1 50 Air flow volume Sound pressure level dB A 42 39 36 33 45 42 37 33 48 46 44 42 SH H M L w o 95 _ Fan motor Running ee 3 8 9 52 1 2 012 7mm 5 8 15 9mm Drain pipe Outline WxDxH mm 848x189x274 945x208x298 1018x223x315 dimension Package WxDxH mm 926 279 359 1013 300 383 1086 328 398 dimension rang amp 44 Connecting pipe Notes The rated cooling capacity data is measured under the following work condition Indoor T
53. display Temperature sensor error The resistance value of discharge temperature sensor is 50 KO The resistance value of outside temperature sensor and inside temperature sensor are all 15 The others 20 Temperature sensor error The plug on temperature sensor is correctly connected to the socket on mainboard 15 it Remove the temperature and measure its resistance value 15 it within normal range Replace the mainboard of unit Check the orientation of plug and socket Replace the temperature sensor 159 MAINTENANCE Super Free Match E Service Manual 3 8 Malfunction display High Low pressure sensor error Pressure sensor error The plug on pressure sensor is correctly connected to the socket on mainboard is it Measure the DC voltage value between blac line and green line of the sensor is it OK 0 5 4 5V Replace the mainboard of outdoor unit MAINTENANCE 0 Check the orientation of plug and socket Replace the pressure sensor 4 POWER DISTRIBUTION 4 1 Diagram of Power Distribution Compressor Driving board 1 Filter board 1 Power supply gt Air swith Testing board Main board of Super Free Match Power supply Air swit
54. electronic electronic expansion valves broken expansion valve When the discharge temperature 1s higher than 110 C whether the compressor reduces No Replace the oudoor unit mainboard its capacity Yes Check the capacity demand of indoor units is it in the range of outdoor Refer to the dial up of indoor and outdoor unit unit capacty Yes Check and repair the leakage of the unit Charge refrigerant according to the required volume 3 4 Malfunction display Current protection Current protection Check the wiring of the compressor 15 1t properly connected Yes Is the current value higher than the preset value of protector Yes high pressure normal Yes Is the voltage normal Yes Replace the mainboard Adjust the compressor wiring Replace the overcurrent protector Refer to high voltage protection Contact the power supply company 157 MAINTENANCE Super Free Match Service Manual 3 5 Malfunction display Communication error Communication error Yes Check the cable of indoor unit 15 it properly connected Yes Check the transmission line between outdoor unit and BU module is it properly connected Yes Measure the transmission line 1s it
55. fixed as close as to the device 3 The drain pipe can be the ordinary hard PVC pipe which can be purchased locally During the connection inset the end of the PVC pipe to the drain outlet then tighten it with the drain hose and binding wire but never connect the drain outlet and the drain hose by adhesive 4 When the drain pipe is used for multiple devices the public section of the pipe should be 100mm lower than the drain hole of each device and it is better to use the much thicker pipe for such a purpose INSTALLATION Super Free Match Service Manual 4 2 12 Installation of the Drain Pipe 1 The diameter of the drain pipe should be larger or equal to that of the refrigerant pipe PVC pipe outer dimater 25mm wall thickness 1 5mm 2 The drain pipe should be as short as possible and with at least a 1 100 degree of slope to avoid forming air pockets 3 If the proper degree of slope of the drain pipe is not allowed a lift pipe should be installed 4 A distance 1 1 5m should be kept between the hangers to avoid the drain hose making a turn 1 1 5m Wrong 5 Insert the drain hose into the drain hole and tighten it with clamps 6 Wrap the clamps with large amount of sponge for thermal insulation 7 The drain hose inside the room also should be insulated 4 2 13 Precautions for the Lift Pipe The installation height of the lift pipe should be less than 850mm It is recommended to set an inclination angle 1 2 for
56. for 10 2 minutes 1 order to dry the indoor unit even though you have turned off the unit After energization X FAN OFF is defaulted X FAN 15 not available in AUTO FAN or HEAT mode 9 Presetting temperature can be increased Press this button the temperature can be set up continuously press this button and hold for two seconds the relative contents can quickly change until unhold this button and send the order that the signal will be displayed all the time The temperature adjustment is unavailable under the Auto mode but the order can be sent if pressing this button Temperature of Celsius degree setting 16 30 Super Free Match Service Manual 10 Presetting temperature can be decreased Press this button the temperature can be button set up continuously press this button and hold for two seconds the relative contents can quickly change until unhold this button and send the order that the signal will be displayed all time The temperature adjustment is unavailable under the Auto mode but the order can be sent by if pressing this button 11 QUIET Press this button the Quiet status 1s under the Auto Quiet mode display G signal and Quiet mode display signal and Quiet OFF there is no signal of G displayed after powered on the Quiet OFF is defaulted Note the Quiet function cannot be set up in Fan and Dry mode Under the Quiet mode Display 49 n Under the Quiet mode Display
57. if the low pressure protection occurs twice in one hour then it has to eliminate the error by powering the outdoor unit again 2 2 7 Compressor overload protection If the compressor overload switch is detected having movement the indoor unit will display the corresponding malfunction as it stops when the indoor temperature reaching set temperature When the compressor stops for more than 3min and the compressor overload switch is reset the unit will resume operation status automatically If the protection appears for more than 6 times if the running time of the compressor 15 longer than 30min the protection times record will be cleared the unit can not resume operation status automatically but can resume running only after cutting off the power and then putting through the power 2 3 Other function 2 3 1 Refrigerant Recovery The refrigerant can be recovered from the outdoor unit When the unit is powered on and runs under the COOL mode it is available within five minute to go the refrigerant recovery mode by operate the testing board of the outdoor unit with Fo displayed 2 3 2 How to quit the refrigerant recovery When the refrigerant recovery has started it will quit by operate the testing board of the outdoor unit or the power is cut off 7 Super Free Match Service Manual 2 4 Control Function of Indoor Unit 2 4 1 Running Mode 1 2 DRY 3 HEAT 4 5 FAN 2 4 2 Basic Functions of the System 1 COOL
58. inaccurate piping 6 9 Leak Test 1 Please make sure that the stop valves of the outdoor unit are closed during the operation 2 The leak test should be made by pressurizing nitrogen gas 3 Open the pressure reducing valve pressurize the connection pipes to 1 0 MPa 10 bar slowly wait ten minutes and make sure that the pressure will not drop 4 Rise the pressure to 4 0 MPa 40 bar slowly wait 24 hours and make sure the pressure will not drop 5 Ifthe pressure does not decrease the pipes have passed the test Otherwise look for where the gas leaks from Outdoor unit Liquid side stop valve Gas side stop valve Pressure vacuum gauge Hi knob Lo knob Pressure reducing valve ala BW Nitrogen 6 10 Vacuum Operation 1 Make sure that the liquid and gas stop valve of the outdoor unit are closed fully during the operation 2 shown in the following figure expel the gas from the refrigerant pipes by the vacuum pump Outdoor unit Liquid side stop valve Gas side stop valve Pressure vacuum gauge Hi knob Lo knob Vacuum pump SYN nA BW NO INSTALLATION Super Free Match Service Manual 3 Open the pump and turn on the knobs to evacuate the gas the liquid and gas pipes 4 When the pressure of the system is less than 0 1 1bar keep the system for more than one hour under the condition 5 Then turn off the knobs and th
59. indoor units Super Free Match E Service Manual INSTALLATION INSTALLATION Super Free Match Service Manual INSTALLATION 1 PRECAUTIONS FOR INSTALLATION 1 1 Precautions for Installation Before installation please ensure the installing site power ratings possible operating range pipe distance height difference between indoor and outdoor unit power voltage and installing space are correct and suitable To ensure correct installation please make sure to read the Safety Considerations thoroughly before starting the installation works After completing the installation and test run and confirming that all are normal please introduce to client on how to use and repair the machine according to the Operating Instructions Besides please deliver the considerations herein to the clients together with the Operating Instructions and ask them to keep properly It indicates improper operation which will lead to human casualty or severe injury It indicates improper operation which will lead to injury property damage The installation should be left to the appointed service center Otherwise it maybe cause water leakage electric shocks or fire etc Please install the air conditioner according to the instructions given in the installation instructions Improper installation may cause fall down water leakage electric shock or fire etc To install a large air conditioning system in a small roo
60. iron wire 4 More noise 15 likely to be produced in the downward return air mode than the backward return air mode so it is suggestive to install a silencer and a plenum box to minimize the noise 5 The installation method can be chose with considering the conditions of the building and maintenance etc INSTALLATION Super Free Match Service Manual 3 Return Duct Air Supply Duct Access Grille 6 4 2 10 Installation of the Condensate Pipe 1 The condensate pipe should keep a inclination angle of 5 10 which can facilitate the drainage of the condensate water And the joints of the condensate pipe should be insulated by the insulation material to prevent condensing Thermal insulation of condensate pipe Pipe cover 2 There is a condensate outlet on both left and right sides of the unit Once one is confirmed to be used the other should be clogged by a rubber plug bundled by the binding wire and insulated by the insulation material to avoid water leakage 3 The right outlet is defaulted to be clogged with a plug CUATION No water leakage is allowed on the joint of the condensate pipe 42 11 Design of the Drain Pipe 1 The drain pipe should always keep an inclination angle 1 50 1 100 to avoid the water gathering in some certain place 2 During the connection of the drain pipe and device do not impose too much force on the pipe on one side of the device and the pipe should be
61. light 1s turned off Y disappears 3 5 2 Introduction for special Operation 1 Child lock function Press and buttons simultaneously can turn on or turn off child lock function When child lock es function is started up icon will be displayed on it If operate remote controller 99 icon will flash three times while remote controller won t send signal 2 Switchover function for temperature display After turning off the unit by remote controller press button and button simultaneously to switch between and F 3 5 3 Guide for General Operation 1 After putting through the power press ON OFF button on remote controller to turn on the air conditioner 2 Press MODE button to select your required mode AUTO COOL DRY FAN HEAT 3 Press or button to set your required temperature Temperature can t be adjusted under auto mode 4 Press FAN button to set your required fan speed auto low medium and high speed 5 Press gt button to select fan blowing angle Super Free Match Service Manual 4 Smart Zone Controller 50 24 4 1 General Introduction 4 1 1 Function Introduction This smart zone controller is a kind of regional controller which is designed for free match units capable of controlling up to 3 outdoor units and 16 indoor units Through this smart zone controller it 15 available to view and control those running parameters of the indo
62. mark them properly Carry out leakage detection under pressure after welding 65 INSTALLATION Super Free Match Service Manual Purge the system clean Keep the pressure for 24 hours Purge and make leakage Except for the influence by temperature it is deemed detection under pressure acceptable if pressure drop 15 within 0 02 With the temperature change by 1 the pressure will change by approx 0 01 MPa The thermal insulation tube must meet the specifications Thermal insulation Seal between the thermal insulation pipes to avoid air entry Select the installing position correctly Build the foundation according to the anchor bolt position Installation of outdoor unit dud the of outdoor unit Build the damping device properly Avoid sharp knock when handling the outdoor unit The inclination angle shall not be higher than 15 Tighten the nuts Connection of indoor unit and outdoor unit Provide proper protection to the outdoor connection pipe communication wires and power supply Keep the pressure for 24 hours Except for the influence by temperature it is deemed acceptable if pressure drop is within 0 02MPa With the temperature change by 1 the pressure will change by approx 0 01 MPa Establish vacuum simultaneously in the gas pipe and liquid pipe Vacuuming The vacuuming time shall be long enough Put still for 1 hour after vacuuming
63. of preventing restart operation 3 minutes Temperature Yes Adjustment Fan Motor Stop Electronic Expansion Electronic Expansion Valve Stop Valve Capacity Conctrol Stop Go to the previous page E Super Free Match Service Manual 1 2 Heating Operation Heating Operation Is there Guide Louver Guide Louver Swing Is the operation of defrosting Is the process of preventing restart operation 3 minutes Yes Fan Motor Stop Is the process Yes preventing Cold Aj Electronic Expansion Valve close Defrosting Control Fan Motor Stop Fan motor As Per Set Air Supply Speed Fan Motor Stop y Electronic Expansion Valve Electronic Expansion Close Valve Capacity Conctrol Super Free Match E Service Manual 2 MAIN LOGIC 2 1 Control Function of Outdoor Unit 2 1 1 Cooling Mode 1 Cooling conditions and process If the compressor is in stop status and start the unit for cooling operation when one of the indoor units reaches the cooling operation condition the unit starts cooling operation in this case the electronic expansion valve the outdoor fan and the compressor start operation 2 Stop in cooling operation a Compr
64. of the air supply duct plus the maximum length of the return air duct Fortheunit with the auxiliary electric heating function if the round duct is to be adopted then the straight length of the transition duct cannot be less than 200mm The duct is either rectangular or round and connected with the air inlet outlet of the indoor unit Among all air supply outlets at least one should be kept open As for the round duct it needs a transition duct of which the size should match with the air supply outlet of the unit After the fitting of the transition duct it is the turn of the round duct which is better to be kept 10 meters far away from the corresponding diffuser The standard accessories supplied by GREE 15 the transition duct 200mm long and round air outlet 9200 however those of other specifications can be purchased 4 2 9 Installation of the Return Air Duct 1 The default installation location of the rectangular flange is in the back and the return air cover plate 1s in the bottom Rectangular Flange Return Air Cover Plate 2 Ifthe downward return air 15 desired just change the place of the rectangular flange and the return air cover plate 3 Connect one end of the return air duct to the return air outlet of the unit by rivets and the other to the return air louver For the sake of the convenience to freely adjust the height a cutting of canvas duct will be helpful which can be reinforce and folded by 8
65. or enquiry status will quit similarly 3 4 2 Guide for General Operation 1 After powered on press ON OFF and then the unit will start to run Note when powered off the guide louver of the main unit will close automatically 2 Press MODE to select the desired running mode 3 Press or to set the desired temperature it is unnecessary to set the temperature under the AUTO mode 4 Press FAN to set the fan speed can select AUTO FAN LOW MEDIUM LOW MEDIUM MEDIUM HIGH and HIGH s 5 Press gt and I to select the swing angle 3 4 3 Guide for Optional Operation 1 Press SLEEP button to set sleep 2 Press TIMER ON and TIMER OFF button can set the scheduled timer on timer off 3 Press LIGHT button to control the on and off of the displaying part of the unit This function may be not available for some units 4 Press TURBO button can realize the ON and OFF of TURBO function 3 4 4 Introduction for special Operation About X FAN function This function indicates that moisture on evaporator of indoor unit will be blowed after the unit is stopped to avoid mould D Having set X FAN function on After turning off the unit by pressing ON OFF button indoor fan will continue running for about 10 2 min at low speed In this period press X FAN button to stop indoor fan directly 2 Having set X FAN function off After turning off the unit by pressing ON OFF button the complete Super Free Match Service Manu
66. p signal the fan speed is not available 12 SWING UP and DOWN Press this button zl to set up amp down swing angle which circularly changes as below X 4 3 gt This remote controller is universal If it receives threes kinds of following status the swing angle will remain 4 original I 7l gt If guide louver is stopped when it is swinging up and down it will remain its present position zl indicates guide louver swings back and forth in the five places as shown in the figure 13 SWING LEFT and RIGHT Press this button 7 1 to set left amp right swing angle cycling as below EH B um m a 1 OFF MM mu 14 TIMER OFF One press this key to enter into TIMER OFF setup in which case the TIMER OFF icon will blink The method of setting is the same as for TIMER ON 15 TIMER ON Timer On setting Signal ON will blink and display signal will once the numerical section will become the timer on setting status During 5 seconds blink by pressing or button to adjust the time value of numerical section every press of that button the value will be increased or decreased 1 minute Hold pressing or button 2 seconds later it quickly change the way of change 15 During the initial 2 5 seconds ten numbers change in the one place of minute then the one place is constant ten numbers change in the tens place of minute at 2 5 seconds speed an
67. power supply properly run at all The batteries voltage of the remote controller Replace with new batteries is insufficient Remote controller is out of the control scope The distance shall be within 8m The unit stops soon inlet or outlet of indoor unit or outdoor u Remove the obstacles after it starts unit is blocked Air inlet or outlet of indoor unit or outdoor ui Remove the obstacles unit is blocked EM Adjust the setting of remote controller or wire Temperature setting 1s controller Adjust the setting of remote controller or wire Air speed is set too low e controller ooling heatin E E 2 Adjust the setting of remote controller or wire is abnormal Improper airflow direction controller Womaypepinemom Note If the air conditioner still runs abnormally after the above check and handling please contact the local appointed service center and also give a description of the error occurred as well as the model of the unit 2 2 Problem Handling The conditions listed below are not classified into errors MAINTENANCE 7 Super Free Match Service Manual Conditions Causes When restart the unit soon after it The overload protection switch of the unit let the The unit does not run is stopped startup delayed for three minutes soon as power supply is on The unit will stand by for approximate one minute The unit blows out mist When the cooling opera
68. so that the room temperature can quickly approach the setting value In the Cooling or Heating mode press Function till the unit enters the Turbo setting interface and then press Enter Cancel to confirm the setting When the Turbo function is activated press Function to enter the Turbo setting interface and then press Enter Cancel to cancel this function Notes a When the Turbo function 1s activated if the difference between the room temperature and set temperature is at or below 2 detected in successive min the Turbo function will be automatically deactivated b Turbo function is unavailable in the Dry and Fan mode And the Turbo function 15 off after power failure and then power recovery If Quiet function 15 on Turbo function will be canceled subsequently 9 E heater Setting E heater auxiliary electric heating function In the Heating mode E heater is allowed to be turned on for improvement of efficiency Once the wired controller or the remote controller enters the Heating mode this function will be turned on automatically Press Function in the Heating mode to enter the E heater setting interface and then press Enter cancel to cancel this function Press Function to enter the E heater setting interface if the E heater function is not activated and then press Enter Cancel to turn it on 10 Blow Setting Blow function After the unit is turned off the water in evaporator of indoor unit will be automatically evapora
69. the current state Set refrigerant n OF represents that the unit isnot The current parameter recovery mode running the current state Di PSS Display suction Suction temperature For temperature example 15 represents 15 Display discharge Discharge temperature For Low pressure For example pressure 95 represents 0 95Mpa pressure 280 represents 2 8 1 3 5 The code of data section Set am temperature H represent High N represent Normal L represent Low Set condensation Set condensation temperature Keys are invalid in the operation 2 Troubleshooting 129 MAINTENANCE Super Free Match Service Manual Warning a In the event of abnormal conditions like stinky smell please shut off the main power supply immediately and then contact the GREE appointed service center otherwise the continuous abnormal running would damage the air conditioning unit and also would cause electric shock or fire hazard etc b Do not repair the air conditioner personally but instead contact the professionally skilled personnel at the GREE appointed service center as the incorrect repair would cause electric shock or fire hazard etc 2 1 Check before Contacting Maintenance Serviceman Please check the following items before contacting the maintenance serviceman Broken fuse or breaker is off Replace the damaged fuse or close the breaker The unit does not Power supply plug is loose Plug the
70. the duct type cassette type or the floor ceiling type indoor unit works with the wired controller the ambient temperature sensor can be set in the following four ways 01 The indoor temperature sensor 15 set for the return air 02 The indoor temperature sensor is set for the wired controller 03 The indoor temperature sensor 15 set for the wired controller under the HEAT mode and for the return air under any other mode 04 The indoor temperature sensor 15 set for the return air under the HEAT mode and for the wired controller under any other mode c Setting of the Ambient Temperature Sensor of the Wired Controller XK19 When the unit is off it is available to go to the debugging status by pressing the Function and Timer buttons for five seconds and the corresponding code will be displayed on the temperature area of the wired controller There are four kinds of codes which can be adjusted through the V A button The 03 is the default code The setting of the ambient temperature sensor of the wired controller should be memorized The Enter Cancel button shall be pressed to confirm and leave the setting If there is no response to the last button press within 20 seconds then the system will quit the setting and go to the normal Off status but with the setting still saved 8 Switchover of the Defrosting Mode On condition that the unit is off if HI 15 not displayed on the wireless controller
71. the fixed position swing Horizontal louver of air conditioner will stop at that position as shown by the icon to swing ri Y When selecting swing angle is displayed dynamically it s the circulating swing Horizontal louver of air conditioner will swing circularly according to the angle as shown by the icon 7 HEALTH SAVE HEALTH function After pressing HEALTH button remote controller will switch circularly as below HEALTH AIR AIR HEALTH no display When selecting HEALTH by remote controller HEALTH function will be started up When selecting AIR by remote controller AIR function will be started up When selecting AIT HEALTH AIR and HEALTH function will be started up When there s no display on remote controller AIR and HEALTH function will be turned off 9 AIR function is applicable for some models SAVE function Under cool mode press SAVE button and unit will operate under SAVE mode Dual 8nixie tube on remote controller displays SE Air conditioner will operate at auto speed Set temperature can t be adjusted Press SAVE button again to exit SAVE mode Air conditioner turn back to original set speed and set temperature This function is applicable to partial of models 5 X FAN After pressing this button under cooling or dry mode remote controller displays the character of X FAN and X FAN function is started up Press this button again to cancel X FAN function
72. the lift pipe toward the drainage direction If the lift pipe and the unit form a right angle the height of the lift pipe must be less than 800mm INSTALLATION Super Free Match Service Manual 1 1 5m Hanger Bracket Ceiling B 300mm 19729 1000 Drain Hose accessory 1 2 Clamp accessory Notes 1 The inclination height of the drain hose should be within 75mm so that the outlet of the drain hose does not suffer the external force 2 If multiple drain pipes converge please follow the installation steps below I Joint of drain pipe 75 1000 88 INSTALLATION Super Free Match Service Manual 4 3 Installation of Cassette Type 4 3 1 4 3 2 Installation Location and Matters Needing Attention The installation of air conditioner unit must be accordance with national and local safety codes Installation quality will directly affect the normal use of air conditioner unit The user 15 prohibited from installation by himself Please contact your dealer after buying this machine Professional installation workers will provide installation and test services according to installation manual Do not connect to power until all installation work 15 completed Select install location of the indoor unit Obstruct should put away from the intake or outlet vent of the indoor unit so that the airflow can be blown th
73. the remote controller is locked m displayed In this case pressing any button blinks three times 2 Combination of MODE and buttons About switch between Fahrenheit and centigrade At unit OFF press and buttons simultaneously to switch between and 3 Combination of TEMP and CLOCK buttons About Energy saving Function Press TEMP and CLOCK simultaneously in COOL mode to start energy saving function Nixie tube on the remote controller displays Repeat the operation to quit the function 4 Combination of TEMP CLOCK buttons About 8 Heating Function Press TEMP and CLOCK simultaneously in HEAT mode to start 8 Heating Function Nixie tube on the remote controller displays 4 and a selected temperature of 8 C 46 if Fahrenheit is adopted Repeat the operation to quit the function 5 About Back lighting Function The unit lights for 4s when energizing for the first time and 3s for later press m Super Free Match Service Manual 3 4 Wireless Remote Controller YAGIFB Notes a Be sure that there are no obstructions between the receiver and the remote controller b Do not drop or throw the remote controller c Do not let any liquid into the remote controller and expose the remote controller to direct sunlight or any place where is very hot d This 15 only use for Hansol indoor unit If press some button which 15 not available for t
74. the unit will keep the original running status 3 2 1 Function of Press Buttons 1 ON OFF 41 Press this button to turn on off the unit After that the sleep function will be canceled but the preset time 15 still remained 2 The preset temperature can be decreased by pressing this button If the button is pressed down for more than 2 seconds the temperature will be decreased quickly until it is released with displayed all the time Under Auto mode the temperature adjustment is unavailable 3 The preset temperature can be increased by pressing this button If the button is pressed down for more than 2 seconds the temperature will be increased quickly until it is released with displayed all the time Under Auto mode the temperature adjustment is unavailable The setting range is 16 30 or 61 86 F 4 FAN Auto Low Middle or High fan speed can circularly selected by pressing this button After powered on the default is Auto speed Under Dehumidifying mode only Low fan speed is available Super Free Match Service Manual gt 44 Medium speed uf High speed 5 MODE Auto Cool Dry Fan Heat modes can be selected circularly by pressing this button Auto mode is the default after power on Under Auto mode the temperature will not be displayed Under Heat mode the initial value 15 28 C 82 F Under other modes the initial value is 25 C 77 t
75. unit make sure the power supply is cut off Removal panel grating module ET Move down the clip of the sub assy of fromt grill until the front grill is open Remove sub assy of As is shown the graph front grill arrow represents the position of bottons There are two clips for each grating Remove right and left finishing plates Illustrations Remove the screws as shown in the graph with screwdriver and then push Remove right and left upward to remove the right finishing plates and left finishing plates mM As is shown in the graph iN arrow represents the ED _______ ____ position of screws Remove panel parts Illustrations Operation Instructions Remove the screws shown by the arrow in the graph with screwdriver two on both right and left and 4 in the front and then remove Remove panel parts the panel parts MAINTENANCE Super Free Match Service Manual Remove sub assy of electric box Illustrations Operation Instructions Remove 3 screws as Remove of electric 4 shown by the arrow in the box cover graph on left and remove the electric box cover Remove the air deflecting plates from the air deflecting plate support assembly and then remove both ends from Remove sub assy of l air sweeping motor joint air deflecting plate l As is shown in the graph arrow represents the supp
76. water trap as shown below Install one water trap for each unit Installation of water trap shall consider easy cleaning in the future Indoor Indoor unit 16 Connection of drainage branch pipe to the standpipe or horizontal pipe of drainage main pipe The horizontal pipe cannot be connected to the vertical pipe at a same height It can be connected in a manner as shown below NOI 3 way connection of drainage pipe joint 3 way connection of drainage pipe joint INSTALLATION NO2 Connection of drain elbow Connection of drain elbow NO3 Connection of horizontal pipe Connection of horizontal pipe Super Free Match Service Manual Drainage pipe is requisite for air conditioner unit During cooling the moisture in the air will condense on the surface of evaporator Such condensing water must be drained out of the unit Meanwhile the drainage pipe has an important role to determine if the air conditioner can plays its full functions 17 the condensate pipes must be installed at a distance over 500mm from the electric box of the unit 03 INSTALLATION Super Free Match Service Manual 9 Installation of Protective Layer on Connection Pipe 1 The refrigerant pipes should be insulated by the heat insulation material and plastic tape in order to prevent water condensation and leakage 2 Do not use the foam on the branch pipe as the material for heat insulation T
77. 000213 1 3301000213 1 33008 mr ur JN INN Electric Box Cover 20122109 20122109 20122123 Sub Assy Electric Box Cover Box Electric Box Cover 20122106 lr 20122106 _ 20122142 mM Cold plasma generator 1114001602 1 1114001602 1 1114001602 m ER ph MAINTENANCE Super Free Match Service Manual Viola GWH 07 RA K3DNA3E I GWH 09 RA K3DNA3E I GWH 12 RB K3DNA3E I GWH 18 RC K3DNA3E I Part list GWH 07 RA K3DNA3E I for CB302N01501 GWH 09 RA K3DNA3E I for CB302N01601 GWH 12 RB K3DNA3E I for CB302N01701 GWH 18 RC K3DNA3E I for CB302N01801 GWH 07 RA K3DNA3E I GWH 12 RB K3DNA3E I GWH 18 RC K3DNA3E I NO Description GWH 09 RA K3DNA3E I Front Panel Assy 20012878 20012858 20012760 Display Board 30565137 30565137 30565121 i 1 29249 MAINTENANCE Super Free Match Service Manual Ps GuideLower 1082204 1 1_ 7917 1 1 1082162 71 of Cross Fan 76512203 76512203 76512203 19 Drainage nose 1 1 05394 1 20 Temp Sensor stevig 052124233 1 1 ome 1 Evaporator Assy omoi 1 1 xum i enm 11 eem 1_ Remot
78. 10A 1 220 240 50 gt Viola Capacity Power Power supply Refrige Model Product code Cooling Heating Appearance rant Ph V Hz kW GWH 09 TA K3DNAIE I CB148N05301 5 75 Super Free Match Service Manual 1 3 2 Duct type Capacity Power supply 5 Model Product code Cooling Heating Appearance Hz kW GFH 12 EA K3DNAIA I CN210N0020 1 3 3 Cassette type Capacity Power supply Model Product code Cooling Heating Appearance rant Hz 10N0040 R410A 1 220 240 50 1 3 4 Floor ceiling type Capacity Power Power supply Refrige Model Product code Cooling Heating Appearance rant Ph V Hz kW kW GTH 12 BA K3DNAIA I CN610N0020 3 5 3 85 1 3 5 Console type Capacity Power supply PA Model Product code Cooling Heating Appearance Hz E ES 09 010 01500 Super Free Match Service Manual 2 NOMENCLATURE 2 1 Nomenclature of Outdoor Unit NO Options Free Match Code Function C Cooling Only H Heat pump Compressor Frequency D DC inverter rotor type 48 represents 48000Btu h 1kW 3 412KBtu Cooling Capacity S represents super free match Climate Type 1 M 380 415V 3Ph 50Hz D 208 230V 1Ph 60Hz Power Supply K 220 2
79. 28 dimension Notes a The rated cooling capacity data is measured under the following work condition Indoor Temperature is 27 C 19 C WB Outdoor Temperature is 35 C DB The rated heating capacity data is measured under the following work condition Indoor Temperature is 20 C DB Outdoor Temperature is 7 6 C WB b The data will change with the change of products Refer to those parameters listed on nameplate Noise was tested 1 semi silenced room so the actual noise value will be a little higher for change of ambient Super Free Match Service Manual gt Cozy GWH 07 MA K GWH 09 MA K GWH 12 MB K GWH 18 MC K n 3DNAJE I 3DNAJE I we SEE Capacity ing cas E Power Hening V Ph Hz 220 240 1 50 220 240 1 50 220 240 1 50 220 240 1 50 Motor power input 0 03 0 03 0 04 0 045 a sm Ee Sound pressure level dB A 36 34 31 28 37 34 31 28 38 34 32 30 46 43 40 36 SH H M L eam on _ Fan motor Running E HN 3 8 9 52mm 3 8 b9 52mm 3 8 D9 52mm 1 2 b12 7mm Connecting SS pino 4 6 35 4 6 35 4 6 35 4 6 35 Connection method Flare Connection Flare Connection Flare Connection Flare Connection External Drain pipe Outline e woa Novas eren dimension Package WxDxH mm 873 251 370 873 251 370 018 258 370 1013 288 395 dimension 20 7 348 Loading quantity 40
80. 3 6 Drainage hose 1 Install the drain hose The diameter of the drain hose should be equal or bigger than the connection pipe s The diameter of polythene pipe Outer diameter 25mm Surface thickness gt 1 5mm Drain hose should be short and drooping gradient should at less 1 100 to prevent the formation of air bubble Ifdrain hose cannot has enough drooping gradient drain raising pipe should be added To prevent bent of the drain hose the distance between hoisting stand should is 1 to 1 5m _______ 27 27 7 2 7 77272 Correct 1 100 more gradient wrong Use the drain hose and clamp attached Insert the drain hose to the drain vent and then tighten clamp Entwine the big sponge on the clamp of drain hose to insulate heat Heat insulation should be done to indoor drain hose INSTALLATION Super Free Match Service Manual Sponge attachment 5 Sponge gray Drain hose Below 4mm 2 Drain stepup pipe note The install height of the drain raising pipe should less than 280mm The drain raising pipe should form a right angle with the unit and distance to unit should not beyond 300mm Roof Within 300mm Hoisting stand Drain hose below 280mm attachment H E Drain raising hose 220mm Ceiling Clam p attachment 3 Instruction The slant gradient of the attached drain hose should b
81. 4 6 35 3 8 9 52 Connection method Flare Connection Flare Connection Flare Connection LE Lm 3s 3 3 Bod Mud 840x840x190 840x840x190 840x840x240 Outline WxDxH dimension Panel mm 950 950 60 950 950 60 950 950 60 WxDxH Body mm 963x963x273 963x963x273 963x963x325 Package WxDxH dimension Panel mm 1043x1028x130 1043x1028x130 1043x1028x130 WxDxH Ba Net Weigh Gros weight 250330 250830 280350 _ Pan _ Notes a The rated cooling capacity data is measured under the following work condition Indoor Temperature is 27 C DB 19 C WB Outdoor Temperature is 35 The rated heating capacity data is measured under the following work condition Indoor Temperature is 20 C DB Outdoor Temperature is 7 6 C WB b The data will change with the change of products Refer to those parameters listed on nameplate Noise was tested semi silenced room so the actual noise value will be a little higher for change of ambient Super Free Match Service Manual 4 2 4 Floor ceiling type E GTH 09 BA K3 GTH 12 BA K3 GTH 18 BA K3 GTH 24 BA K3 um pump DNA1A I DNA1A I Cooling KW 2 50 3 50 5 00 7 10 cw xes m6 Sound pressure level dB A 40 38 36 40 38 36 45 42 40 48 46 44 H M ER oos Fan motor Running 3 8
82. 40 _ Sound pressure level cooling heating dB A 58 58 eve Volume 7000 7000 Nominal input Control Electronic expansion valve Refrigerant oil Compressor Piping 15 9 19 05 Senet om Piping length total OU BU anm EN BU IN 4 4 o Height BU BU IN IN E B Operation range Notes a The rated cooling capacity data is measured under the following work condition Indoor Temperature is 27 C DB 19 C WB Outdoor Temperature is 35 C DB The rated heating capacity data is measured under the following work condition Indoor Temperature is 20 C DB Outdoor Temperature is 7 6 C WB b The data will change with the change of products Refer to those parameters listed on nameplate c Noise was tested in semi silenced room so actual noise value will be a little higher for change of ambient Super Free Match Service Manual 4 2 Product Data of Indoor Unit 4 2 1 Wall mounted gt Hansol GWH 07 TA K GWH 09 TA K GWH 12 TB K GWH 18 TC K ode 3DNAIE I 3DNAIE I 3DNAIE I 3DNAIE I apaci Power supply V Ph Hz 220 240 1 50 220 240 1 50 220 240 1 50 220 240 1 50 u flow volume SH H MH M ML L SL 24 21 24 21 24 21 33 30 Fan motor Running a rr inch 1 2 12 7mm 5 8 15 9mm pipe Flare Flare Flare Flare Connection method Connection Connection WE 2 ME m Drain pipe
83. 40V 1Ph 50Hz O Outdoor unit 2 2 Nomenclature of BU Module ___ 30 r Assembly type FX branch module D Number of port 2 two ports 3 three ports 5 five ports 3 Design eade A B W Wall mounted type F Duct type 2 Product Type m K Cassette type E Console ceiling type 12 represents 12000Btwhh 1kW 3 412KBtu _______ Alphabets Series code Shallcode 6 Power Supply K 220 240V 1Ph 50Hz D 208 230V 1Ph 60Hz PRODUCT Super Free Match Service Manual 3 FUNCTION Wall Cassette Floor Console Function Duct type d type Fan operation Mode Mode Timer Selector Auto Mode For Comfortable e e e Air Conditioning HeatMode Operation e e e DryMode Operation FanMode Operation e sleepmodeseting or Flexible Contro Wireless Remote Controller Have Functions No Functions Super Free Match Service Manual 4 PRODUCT DATA 4 1 Product Data of Outdoor Unit GWHDGSSJNM3CO GWIHDGGS NMS CO emi p Heating 4 25 EER COP 2 9 3 2 2 8 3 5 8 9 Total rd index of to be connected Dimeson wWxp mm 19598 20 13499003
84. 8601 1 38 EM Wall Mounting 18 01252484 1 01252484 1 01252123 1 19 Motor Press Plate 26112209 1 26112209 1 26112330 1 Rubber Plug Water 76712012 76712012 76712012 ee 3 SepMow 209 3 1501208602 3 25 2onaision 1 1_ 26 Box Cover 2012240901 1 2012240001 1 2012240001 1 jumper 4202300101 1 4202300103 1 1 MainBowd 1 1 29 Box Assy 24058 1 1 24059 1 30 Box Cove 2012207 1 20122075 1 0242 f Pai sewcwe 1 29506 23 3 Pipe Connection Nut 32 06320020 l 06320020 l 06320020 l accessories Connecting Cable 4002052317 4002052317 4002052317 HE Ambient 390000451 390000451 390000451 Remote Controller 30510137 30510137 Es 30510137 xm MAINTENANCE E Super Free Match Service Manual U Cool GWH 07 UA K3DNAIB I GWH 09 UA K3DNA1B I GWH 12 UB K3DNA1B I 40 41 42 4 45 46 Part list GWH 07 UA K3DNAIB I for CB204N02600 GWH 09 UA K3DNAIB I for CB204N02700 GWH 12 UB K3DNAIB I for CB204N02800 GWH 07 UA K3DNAIB I GWH 12 UB K3DNA1B I Description GWH 09 UA K3DNAIB I Front Panel Sub Assy 2001269506 2001285901 Filter Sub Assy 11122122 11122134 179 MAINTENANCE Super Free Match Service Manu
85. BU module should be level in front back and left right INSTALLATION Outdoor unit 6 REFRIGERATION PIPING WORK 6 1 Manifold Mode of Connecting Pipe 1 For only one BU module there will not be more than five indoor units Outdoor unit 2 Fortwo BU modules there will not be more than nine indoor units BU Branch pipe E Super Free Match Service Manual Indoor unit E ai A ls a a Indoor unit 7 103 INSTALLATION Super Free Match Service Manual 3 For three BU modules there will not be more than nine indoor units Branch pipe 2 Outdoor unit Branch pipe 1 Oo The 1st branch 14 branch TE H3 L BB Indoor unit 113 INSTALLATION 7 Super Free Match Service Manual Between outdoor unit and BU L1 L2 L3 L4 L5 Total length between NEMO CO 1A 1B 1C 2A 2B 2C Maximum llowabl indoor units and BU allowable Between Between indoor unit and BU module unit and BU module 1A 1B 1C 2A 2B 2C 3A 3B Se length L4 1B L2 L5 2A Between indoor unit and the 1st branch L2 L3 3B Maximum allowable length Minimum Between outdoor and the 1st branch allowable as possible Between BU and the branch L3 L4 L5 length as short 6 3 Dimension of Connecting Pipe Gas Pipe Gam Liquid Pipe
86. GWHD 48S NM3CO 15 9 9 52 Outdoor unit GWHD 56S NM3CO 019 05 Between outdoor unit and 1st branch The pipe L1 019 05 09 52 Between the Ist and the 2nd branch The pipe L2 015 9 9 52 6 4 gei of Branch Pipe If two or three BU modules used Y type branch pipe of FQ01A A will be chosen PE Liquid pipe Gas pipe 2 branch pipe is equipped with auxiliary tubes to adjust the diameter of different pipes If the dimension of the pipe selected is different from the dimension of branch pipe joint Cut the copper tube in the middle with tube cutter and clear up burrs Please do that as following figure Outlet Outlet IEEE Cut in the middle Cut in the middle Cut in the middle 3 Y type branch pipe must be installed in vertical or horizontal direction In inlet of the branch pipe keep at least 500mm straight pipe 7 105 INSTALLATION Super Free Match Service Manual Within 30 Withinz30 C 6 5 Design Requirements for Oil Trap If the height different between the indoor unit and outdoor unit exceeds 6m one oil trap shall be installed every 6m from lower to upper on the vertical section of gas pipe The oil trap shall be fabricated into two U type elbows or one return type elbow The height shall be 3 5 times the piping diameter See below for details on installation and fabrication of oil trap 1 The oil trap may be fabricated into U type or r
87. IVER AND WARNING SENSOR SENSOR DISPLAY BOARD Please don t touch DISPLAY component or termina when ay T r RT2 MAGNETIC than 3 minutes to prevent electric shock TUBE DISP DISP2 DC MOTOR XT AP1 PRINTED CIRCUIT BOARD N NOD COM OUT BEEF OUTDOOR UNIT 4 d SPE TAL BOX __ JUMP uix YEGN SW I NG DOWN abis UP CN8 TERMINAL CY HEALTH L HEALTH N 2 fi P3 5 STEPPING STEPPING COLD PLASMA MOTOR MOTOR SELECT GENERATOR SWITCH MAINTENANCE 7 Super Free Match Service Manual 4 2 3 BU module FXB3A K XTB W17BK EF fa be 2DK RTIA pips tube senzor 20K ATZA A Suid pigs tube zenznr 20K 2T3E unit pips tube mcnznr 208 RT4B lees ndor B lizuid pigs tube sensor T4 IS Indoor unit unit B 20K D _ 8 unit paa pips tube zcnzar SOK ndear b liquid pige tue seer P Indoor unit Qutdoonnte SU module YEGM 1 5 i Sketch of Electric Parts X Fi M ur A uf Electronic Electronic E ectren BU module
88. Mode Under this mode the fan and swing function goes as the set conditions and the set temperature range is 16 C 30 C 2 DRY Mode Under this mode the fan will run at the low speed and the swing function is performed under the set conditions The set temperature range is 16 30 3 FAN Mode Under this mode only the fan of the indoor unit runs And if the auto speed 15 set the fan will run under the same condition as the COOL mode 4 HEAT Mode a Under this mode the set temperature range 15 16 30 b The defrosting symbol will be displayed when the defrosting signal is received from the outdoor unit 5 AUTO Mode a When the ambient temperature is higher than 25 the unit will run as the COOL mode b For the cooling and heating unit if the ambient temperature is or lower than 22 C the unit will run as the HEAT mode c When the indoor ambient temperature is higher than 22 but lower than 26 the unit which starts to work under the AUTO or DRY mode will shift to the FAN mode while the unit which starts to work under other mode will keep the current running mode 2 4 3 Other Control 1 Control When the controller is powered on or it receives a valid either press button signal or remote control signal the beeper will utter a warning tone 2 Auto Speed Control a Under the HEAT mode Ifthe ambient temperature is equal or higher than the set temperature the fan will run at the lo
89. SIALLATION 67 3 eniti ba 68 221 PrecauHons TOt R4 T0 68 3 2 Precaution tor InstallattOfi 68 3 9 Names MIT EAN 5 68 Pars and Components OF e be i ees petet due 69 325 Selection or Installatton WOCAU OM 70 3 6 Outline Dimension of the Outdoor ee ccccccecccecceeeeeeeeeeeaaeeeeesesseseeeeeeeeeeeeeseeeaaaas 71 3 7 Servicing 71 3 8 Installation ot the Outdoor Unit tute a ER Rea e 72 4 INDOOR OUNITINSTAEEATION 73 4 1 Installation or Wall Mounted aa Sua bo ines 73 or DHCE ener 76 4 3 Cassette Ty De mcn bi vn s abe aera eae 84 2 4 AIS CAAT OO Cete 90 4 5 Installation or Console as iu e Sab 94 3 MODULE INSTALLATION 98 tor
90. Sleep mode 1 in Cool or dry mode after run for one hour in sleep mode the main unit setting temperature will increase after 2 hours the setting temperature will increase 2 but the maximal setting temperature 15 30 then the unit will run at this setting temperature all along In Heat mode after run for one hour in sleep mode the setting temperature will decrease after 2 hours the setting temperature will decrease 2 but the minimal setting temperature 15 16 then the unit will run at this setting temperature all along Sleep 2 is sleep mode 2 that is air conditioner will run according to the presetting a group of sleep temperature curve In Cool mode D When setting the initial temperature 16 23 after turned on Sleep function the temperature will be increased 1 in every hour after 3 the temperature will be maintained after 7hours the temperature will be decreased 1 after that the unit will keep on running under this temperature 2 When setting the initial temperature 24 C 27 C_ after turned on Sleep function the temperature will be increased 1 in every hour after 2 the temperature will be maintained after 7hours the temperature will be decreased 1 after that the unit will keep on running under this temperature 3 When setting the initial temperature 28 C 29 C after turned on Sleep function the temperature will be increased 1 in every hour after 1 the temperature will be
91. a Notes The rated cooling capacity data is measured under the following work condition Indoor Temperature is 27 DB 19 C WB Outdoor Temperature is 35 CDB The rated heating capacity data is measured under the following work condition Indoor Temperature is 20 C DB Outdoor Temperature is 7 6 CWB b The data will change with the change of products Refer to those parameters listed on nameplate c Noise was tested in semi silenced room so the actual noise value will be a little higher for change of ambient Super Free Match Service Manual 4 2 3 Cassette Cooling 3 50 4 50 KW m 64 Fan motor TXCHETS Connecting nes Drain pipe mm 570x570x230 570x570x230 Outline WxDxH dimension Panel mm 650 650 50 650 650 50 WxDxH mm 851x731x325 851x731x325 Capacity Package dimension Super Free Match Service Manual GKH 12 BA K3 GKH 18 BA K3 GKH 24 BA K3 Model Heat pump DNAIA I DNAIA I DNAIA I Cooling 3 50 5 00 7 10 Heating 3 85 5 50 8 00 Power we V Ph Hz 220 240 1 50 220 240 1 50 220 240 1 50 _ flow volume Capacity Sound pressure level HIL dB A 37 35 33 37 35 33 39 37 35 Output Output 0 035 0 035 035 Fan motor 9 0 o 3 8 9 52mm 1 2 b12 7mm 5 8 15 9 onnectin 1 4 6 35 1
92. al x Pug 1 1 m 1 1932084 1 5 2 gt 26 Shaft ofGuide Louver 6 1050030 6 25 Magnetic Ring 45004 1 3 Wirecamp 7 1 x 309 1 XL 2 10 e 0 7 a EMEN Shield Cover Sub assy of Electric 01592113 01592301 pL eee ns a Lower Shield Sub assy Box 0593300 1 01592390 1 39 Electric Box Assy 20102000073 1 200209072 1 40 Pipe Connection Nut Accessories 06320005 1 05209 1 Temperature Sensor 390000853 1 1 Connecting 9 MAINTENANCE Super Free Match Service Manual GWH 18 UC K3DNAIB I da Part list GWH 18 UC K3DNA1B I for CB204N02900 GWH 18 UC K3DNA1B I escri lon 99 4 4 Gide tower 1 3 19 017 ___ 1 Raber Plug Watery i1 MAINTENANCE Super Free Match Service Manual _______ o 16 ans E
93. al unit will be off directly About AUTO RUN If start this function the unit will run at super high fan speed to cool or heat quickly so that the ambient temperature approaches the preset temperature as soon as possible Aboutlock Press and buttons simultaneously to lock or unlock the keyboard If the and remote controller 15 locked the icon Em will be displayed on it in which case press any button the mark will flicker for three times If the keyboard 15 unlocked the mark will disappear About swing up and down 1 Press swing up and down button continuously more than 2s the main unit will swing backand forth from up to down and then loosen the button the unit will stop swinging and present position of guide louver will be kept immediately 2 Under swing up and down mode when status is switched from off to if press this button again 2s later zi status will switch to off status directly If press this button again within 2s the change of swing status will also depend on the circulation sequence stated above About swing left and right Press swing left and right button continuously more than 2s main unit will swing back and forth from left to right and then loosen the button the unit will stop swinging and present position of guide louver will be kept immediately 2 Under swing left and right mode when the status is switched from off to I if press this butto
94. ality will directly affect the normal use of air conditioner unit The user is prohibited from installation by himself Please contact your dealer after buying this machine Professional installation workers will provide installation and test services according to installation manual Do not connect to power until all installation work is completed 4 2 2 How to select the installation location for the indoor unit Where there is no direct sunlight 9 Where the top hanger ceiling and the building structure are strong enough to withstand the weight of the unit Where the drain pipe can be easily connected to outside Where the flow of the air inlet and outlet are not blocked Where the refrigerant pipe of the indoor unit can be easily led to outside Where there is no inflammable explosive substance or their leakage Where there is no corrosive gas heavy dust salt mist smog or moisture The unit which 15 installed in the following places is likely to run abnormally If unavoidable please contact the professional personnel at the GREE appointed service center 1 Where 15 full of oil 2 Alkaline soil off the sea 8 Where there is sulfur gas like sulfur hot spring 4 Where there are devices with high frequency like wireless devices electric welding devices or medical equipments 5 Special circumstances 4 2 3 Caution for Installation Ensure the hanger is strong enough to withstand the weight of
95. allation and test services according to installation manual Do not connect to power until all installation work is completed 4 1 2 Basic Requirements for Installation Position Installing the unit in the following places may cause malfunction If it is unavoidable please consult the dealer The place with strong heat sources vapors flammable or explosive gas or volatile objects spread in the air The place with high frequency devices such as welding machine medical equipment Place where a lot of salinities such as coast exists Place where the oil machine oil or fumes is contained in the air Place where a sulfured gas such as the hot spring zones is generated The appliance shall not be installed in the laundry Other place with special circumstance 4 1 3 Indoor Unit Installation Position Selection There should be no obstruction near air inlet and air outlet 9 Select position where the condensing water be dispersed easily and won t affect other people otherwise the place is easily connected for outdoor unit Select a location where the children cannot reach 9 Can select the place where is strong enough to withstand the full weight and vibration of the unit And will not increase the noise Be sure to leave enough space to allow access for routine maintenance The height of the installed location should be 250 cm or more from the floor Select a place about 1m or more away from TV s
96. alve Coil 43045288 1 30413208 1 _Sub cool Copper Assy 1 1 _______ 3241009 1 30224100002 1_ 5 TemmiBad 3 1_ 57 0 0 rss Testing Board 30118000003 1 30118000003 1 1 3926008 1 1 1 4 MAINTENANCE Super Free Match Service Manual 7 2 Indoor unit 7 2 1 Wall mounted type Hansol GWH 07 TA K3DNA1E I GWH 09 TA K3DNA1E I GWH 12 TB K3DNAIE I GWH 18 TC K3DNAIE I 4 Part list 07 for CB148N05201 GWH 09 TA K3DNAIE I for CB148N05301 GWH 12 TB K3DNA1E I for CB148N05401 GWH 18 TC K3DNALIE I for CB148N05501 GWH 07 TA K3DNAIE I m K3DNAIE X K3DNAIE NO Description K3DNAIE I TI a a Guide Louver small 10512176 i 10512127 E 1051222601 10512234 left 10512232 left Air Louver 1051228601 10512235 Right 10512233 Right Helicoid Tongue 2611226001 2611224401 2611236701 sub assy 177 MAINTENANCE Super Free Match Service Manual Left Axile Bush 10512037 10512037 1051203701 Propeller Axile Bush 1054202101 1054202101 1 105420470 1 Evaporator Support 24212114 24212114 1 24201139 1 LN posee mM omm 1114001602 1114001602 1114001601 Generator Evaporator Assy 0100233801 01002904502 1 010023
97. and screw the fixing bolts 9 Mount the water tray and screw the screws MAINTENANCE E Screw the bolts Screw the fixed bolts of the motor Mount the fan and screw the fixing bolts Mount the water tray and screw the screws Removal and Assembly of drainage pump Super Free Match Service Manual Remark Prior to the assembly of the drainage pump make sure the power supply is cut off 1 Unscrew the fixed screws of the water tray 2 Remove the water tray 3 Pull out the drainage pipe and unscrew the fixed screws the water pump 4 Take out the pump and replace it Illustrations Operation Instructions Unscrew the screws Unscrew fixed screws of the water tray Remove the water tray Pull out the drainage ES Pull out the drainage pipe Unscrew the screws and unscrew the fixed screws the water pump Remove the water pump Take out the pump and replace it 019 MAINTENANCE Super Free Match Service Manual 5 Connect the drainage pipe and screw the fixed screws the water pump 6 Mount the water tray and tighten the screws MAINTENANCE Connect the drainage pump Screw the fixed screws Connect the drainage pipe and screw the fixed screws the water pump Mount the water tray and tighten the screws Super Free Match Service Manual 6 2 5 Floor ceiling type Remark Prior to the assembly of the indoor
98. ce which 15 full of machine oil A region with saline sodic soil near the sea A place where the sulphide fog exists such as the sulphur spring 9 place where the high frequency facilities exist such as radio equipment electric welder and medical equipment An environment with special conditions 99 INSTALLATION Super Free Match Service Manual 5 5 Outline Dimension and Servicing Space of FXB3A K 1 Outline dimension 463 Gas pipe 2 Installation and service space Wall INSTALLATION 7 Super Free Match Service Manual 5 6 Outline Dimension and Servicing Space of FXB5A K 1 Outline dimension 463 amp 70 Indoor unit side mm Outdoor unit side mm Liquid pipe 06 35 09 52 Gas pipe 2 Installation and service space Wall 7 INSTALLATION Super Free Match Service Manual 5 7 Installation Instruction 1 Check the installation location and ensure it is strength and level Otherwise there should be enough space to install drainage pipe so that the condensed water can be discharged 2 Reference to the size of hanger metal and drill 4 holes in the installation location 3 Hang the hanger bolts 4 Fix the modules securely with the hanger bolts You can get the M10 or M8 hanger bolts nuts and washers from the market Bolt Nut Hanger metal BU modlue 5 Adjusting the nuts position so that the
99. ch Service Manual Main board of outdoor unit Control signal of temperature sensor 4 way valve electronic expansion valve high and low pressure switch electric heating tape etc gt Indoor unit Control signal of temperature sensor electronic expansion valve etc The thick line represents power line while thin line represents the control line 7 MAINTENANCE Super Free Match Service Manual 4 2 Wiring diagram Note This drawing is just for reference please always refer to the electric wiring stuck to the unit for actual wiring 4 2 1 Outdoor unit GWHD 56S NM3CO GWHD 48S NM3CO if POWER ED 11 w3 RE 12 E ADO YEG pe z HIGH PRESSURE SENDIR Fi ws 93 m r a TUE m EH F E o 1 __ pem erm D sss sme 5 m se ETT S ps FH Du ws _ 1 d 1 n ELECTRIC CONTROL BOARD Ens uL BIFURCATION s 7 T T TL F Rr n 4 UNIT Tee
100. cm to avoid condensing 11 Ensure a gradient over 1 when connecting the drainage pipe to the indoor unit gem Correct 1 100 or more gradient x wrong 12 When connecting the drainage pipe to the indoor unit please fix with the included pipe clamp and do not use glue water thus to ensure easy repair 13 Installation requirements for auxiliary drainage pipe Pipe clamp Drainage PVC pipe Unit drainage pipe Drainage hose The auxiliary drainage pipe must be thermally insulated Thermal insulation of condensate pipe he B gt Ie _ 22 Pipe cover 14 The long drainage pipe may be fixed by using hanger bolts thus to ensure a gradient of 1 100 PVC cannot be bent The spacing between the supports of horizontal pipe is 0 8 1 0m Twisting will be caused and thus air bag will be formed if the spacing 15 too high Once the air bag is formed the pump can only compress the air bag no INSTALLATION Super Free Match Service Manual matter how forcible it pushes but there 15 no flowing water thus resulting in abnormal water level This will cause flooding of the ceiling dE 15 Ifthe flow of indoor unit is high this might cause negative pressure and result in return suction of outdoor air Therefore U type water trap shall be designed on the drainage side of each indoor unit Indoor unit Install
101. compressor can resume running after cutting off the power and then putting through the power If the running time of the compressor is longer than 7min the protection times record will be cleared 2 2 3 Discharge Protection Function When the discharge temperature 15 a little low the compressor raises the operation frequency when the discharge temperature is a little high the compressor frequency is restricted or lows down the operation frequency when the discharge temperature 15 too high the compressor protection stops running If the discharge temperature protection continuously appears for 6 times the compressor can t resume running The compressor can resume running after cutting off the power and then putting through the power If the running time of the compressor is longer than 7min the protection times record will be cleared Super Free Match Service Manual 2 2 4 Communication malfunction Detection of the quantity of installed indoor units and BU modules After 3min of energizing if the outdoor unit does not receive the communication data of certain indoor unit the outdoor unit will judge that indoor unit is not installed and will treat it as it is not installed If the outdoor unit receives the communication data of that indoor unit later the outdoor unit will treat that unit as it is installed 2 2 5 Compressor high pressure protection 1 When the high pressure switch is detected cut off for 3s continuously the c
102. ction slowly and completely 2 If the pressure of the system is too high to charge refrigerant you can do as follow 1 Turn on the liquid and gas side stop valves in an anticlockwise direction slowly and completely INSTALLATION amo 7 Super Free Match Service Manual 2 Turn on the power of the air conditioner and set cooling mode running more than 0 5h when outside temperature is higher than 18 C DB a Refer to the left of the figure connect the R410A tank to the system b Turn on the R410A tank and the Lo knob charge the R410A refrigerant into the system from the gas side stop valve The Hi knob should be closed completely c Turn off the R410A tank and the Lo knob immediately when adding refrigerant is enough 8 Turn on the power of the air conditioner and set heating mode running more than 0 5h when outside temperature is lower than 18 a Refer to the right of the figure connect the R410A tank to the system b Turn on the R410A tank and the Hi knob charge the R410A refrigerant into the system from service port The Lo knob should be closed completely c Turn off the R410A tank and the Hi knob immediately when adding refrigerant is enough Caution Make sure the liquid and gas side stop valves are opened completely after the installation Make sure the length of liquid pipe is exactly Additional refrigerant charge must be measured exactly Make sure that the refrigerant which charge into the unit 15 in li
103. curely after finishing the electric work Fix each ground wire separately with the ground screw When connecting indoor units make sure to connect refrigerant pipes and power cables to the same connection ports marked with matching signs Ifthe connecting wire is connected to the terminal incorrectly the unit will not work normally 7 8 Instructions for DIP Switch 2 digits DIP is adopted to assign the address when using multi BU modules and the address cannot be repeated in the same unit One outdoor unit can connect to no than 3 BU modules side means 1 and number represents 0 Note The black part is lever DIP Code Number Icon Address DIP 1 DIP 2 ON EBENEN 7 9 Electrical Wiring Work for Indoor Unit 1 Open surface panel 2 Remove electrical box cover 3 Route the power connection cord from the back of the indoor unit and pull it toward the front through the wiring hole upward 4 Connect the wiring communication through the piping hole of the chassis and the bottom of the appliance upward then connect the brown wire to the Terminal board 3 black wire the communication wire to the Terminal board 2 wire to the Terminal board N 1 and connect ground wire to the screw terminal on the electric box Clamp them with the corresponding wire clamp INSTALLATION 5 6 7 7 Super Free Match Service Manual packed in the chas
104. d carry During 5s blink press the Timer button the timer setting succeeds The Timer On has been set up repress the timer button the Timer On will be canceled Before setting the Timer please adjust the Clock to the current actual time 16 I FEEL Super Free Match Service Manual Press this button once to turn on the I FEEL function then the figure of I FEEL will be displayed after every press of other function button every 200ms to send I FEEL once after this function started the remote control will send temperature to the main un it every 10 minutes When repress this button this function will be turned off 17 ZIugALTHY AND SCAVENGING Press this button to achieve the on and off of healthy and scavenging functions in operation status Press this button for first time to start scavenging function LCD displays Press the button for the second time to start healthy and scavenging functions simultaneously LCD displays and Press this button for third time to quit healthy and scavenging functions simultaneously Press the button for the fourth time to start healthy function LCD display Press this button again to repeat the operation above Note Optional for some models 18 SLEEP 1 2 L 3 Press this button can select Sleep 1 Sleep 2 62 Sleep 3 GC and cancel the Sleep circulate between these after electrified Sleep Cancel is defaulted Sleep 1 is
105. e 2698 1 Remote Conroe 3993 1 a6 1 a Terminal Board 1_ Capacitor 1 sete Box Cover a 5 Tambme s Main Board 20008880 2 1 MAINTENANCE Super Free Match Service Manual 7 2 5 Console type GEH 09 AA K3DNAIC I GEH 12 AA K3DNAIC I GEH 18 AA K3DNAIC I y A Kt M MAINTENANCE Super Free Match Service Manual Part list GEH 09 AA K3DNAIC I for CV010N01500 GEH 12 AA K3DNAIC I for CV010N01600 GEH 18 AA K3DNAIC I for CV010N01700 GEH 09 AA K3 GEH 12 AA K3 GEH 18 AA K3 RearCaseassy 1 22 046 1 71 3 1 is 1 Step Motor 1 1521210805 1 1820805 71 T Connecting Cable 40204056 40020456 0 400204055 o Pipe Connection Nut 31 06320020 06320020 1 06320020 1 accessories Ambient Temperature 32 3900004508 1 3900004508 1 3900004508 1 MAINTENANCE 7 Super Free Match Service Manual 7 3 BU Module FXB3A K 31 cu c4 c Part list NO D
106. e it is unnecessary to set the temperature under the AUTO mode 4 Press FAN to set the fan speed Auto Low Medium or High Super Free Match Service Manual 5 Press select the swing angle 3 2 3 Guide for Optional Operation 1 About X FAN This function indicates that moisture in the evaporator of the indoor unit will be dried after the unit 1s stopped to avoid mould X FAN ON When press the ON OFF button to turn off the unit the indoor fan will continue running for about another 10 minutes at the low speed In this case the indoor fan can be stopped directly by pressing the button X FAN X FAN OFF When press the ON OFF button to turn off the unit the whole unit will be stopped completely 2 About AFTERHEAT X FAN Under the Heat mode or Auto Heat mode if the unit 15 turned off the compressor and outdoor fan will stop running immediately and the upper and lower guide board will rotate to the horizontal position while the indoor fan will still run at the low fan speed Then 10 seconds later the unit will stop completely 3 About AUTO RUN When AUTO RUN is selected the setting temperature will not be displayed on the LCD and the unit will choose the suitable running mode automatically in accordance with the room temperature About TURBO If this function is activated the unit will run at super high fan speed to cool or heat quickly so that the ambient temperature will approaches the preset tempe
107. e Controller 305100491 305100491 1 305100491 LM Comecing Cable 00205217 79717 747 25 wa Monine Fame oes 1 26 Pipe Clamp 1 1 ____ remus 1 isorz0e 1 Menem a mec 2 Water Tay 1 emen 1 1 3 _ 1 ism 1 71 1 seo 1 1 x Foam Watertayy 1 mme 1 xm 1 ___ 1 20400546 1 2040088 1_ 1 1 71 3 Terminal Board um 1 enm 1_ Box Covert 1 1 2024 1 Shield cover of Electric 37 0141203601 0141203601 1 01592092 1 Ambient Temperature 390000453 390000453 390000453 Capacitor CBB61 33010002 ZW 33010002 33010043 Jumpr 420230017 E 4202300119 Hs 4202300121 E Shield cover of Electric 0159207301 0159207301 01592092 Box sub assy Cold plasma generator 1114001602 1114001602 1114001602 p 1 MAINTENANCE amo Super Free Match Service Manual GWH 24 RC K3DNAIA I Part list GWH 24 RC K3DNA1A I for CB144N01100 GWH 24 RC K3DNAIA I escri lon RaCwemy 5
108. e on the same gradient The two ends of 2 way section shall not have different gradient See the schematics below Wrong connection Correct connection 5 Confluence toward the horizontal pipe shall be best from the upper Back flow is easy to occur if from the lengthwise direction Indoor Unit Mounting of a horizontal pipe N EN b __ 7 7 i 1 u Main A Main lt E Main 77 pipe pipe pipe A A X 6 Do nottie the condensate pipe and refrigerant pipe together 7 To ensure smooth drainage of condensate vent hole shall be set at the highest point of drainage pipe 8 Carry out water flow test and full water test after the pipe connection 1s completed On one hand check INSTALLATION m Super Free Match Service Manual if the drainage is smooth on another hand check the piping system for any leakage 9 Steel sheath shall be provided to the pipe crossing the wall or slab The pipe joint shall not be positioned within the sheath The steel sheath shall be flush with the wall surface or slab base but 20mm higher than the slab base The sheath shall not affect the pipe gradient The clearance between pipe and sheath shall be blocked by using flexible inflammable materials The sheath shall not be used as the supporting point of the pipe 10 The joint of thermal insulation materials must be adhered by using special glue and then wrapped with plastic tape having a width not less than 5
109. e pump make sure the power supply is cut off Illustrations Operation Instructions Clasps at two sides of front panel MIS Slight press the locks at both ends of the front panel to open one side of it and then undo 1 Remove the front three clasps to open the other panel side of the panel after that remove the panel upward away from the unit Unscrew the screws LLL LL Lm _ 7 _ jw Unscrew the fixed screws of EN __ 2 Unscrew the fixed Ss EE the front panel and main body screws of the unit Remove the front panel 3 Remove the front assembly upward away from panel assembly l the unit 4 Unscrew the fixed T Unscrew the screws around screws 5 Remove the drain d bracket Remove the drain pan and the an and the bracke e the filteri bracket of the filtering screen of the filterin upward away from the unit screen MAINTENANCE M Unscrew the screws 6 Unscrew the fixed screws of drainage pump 7 Remove drainage pump and replace it 8 Connect the water pipe to the drainage pump 9 Install the drain pan and the bracket of the filtering screen 10 Install the front panel assembly 11 Install the front panel Press the locks m Super Free Match Service Manual Unscrew the fixed screws of drainage pump Remove drainage pump and
110. e than 2 seconds the time will be changed quickly in such a way firstly the value on the one s place is changed and then is the value on the ten s place Once Timer ON has been set already it can be canceled by repressing it Before the setting please adjust the CLOCK to the current actual time lt 11 SWING UP DOWN gt h The swing angle which circularly changes as below can be selected by pressing this button Super Free Match Service Manual AA gt This kind of remoter controller is universal And the three swing statuses of 1 21 same as that If the swing function 1s deactivated when the air guide louver is swing up and down it will stop at the current Mz of position indicates that the air guide louver swings up and down among all five positions zA indicates that the air guide louver swings up and down among all five positions 12 X FAN Pressing X FAN button in COOL or DRY mode the icon is displayed and the indoor fan will continue operation for 10 minutes in order to dry the indoor unit even though you have turned off the unit After energization X FAN OFF is defaulted X FAN is not available in AUTO FAN or HEAT mode 13 TEMP It can be decided by pressing this button which temperature will be displayed indoor set temperature or indoor ambient temperature When the indoor unit is powered on the indoor set temperature will be display
111. e within 75mm so that the drain hole doesn t have to endure the unnecessary outside force below75mm below500mm Please install the drain hose according to the following process if several drain hoses join together Abovel00mm T tie in join drain hose The specs of the selected join drain hose should fits the running capacity of the unit INSTALLATION 8 Super Free Match Service Manual 4 Check the smoothness of drain after installation Check the drain state by immitting 600cc water slowly from the outlet vent or test hole Check the drain in the state of refrigerating after installation of the electric circuit Way of immiting Drain hose Drain vent for repair use plastic stopper is included drain the water in waterspout by this outlet vent Abovel00mm Plastic water pot The length of the e pipe should be about 100mm 2 lt Immiting water from the outlet vent terminal gt INSTALLATION Super Free Match Service Manual 4 4 Installation of Floor Ceiling Type 4 4 1 Important Notices The installation of air conditioner unit must be in accordance with national and local safety codes Installation quality will directly affect the normal use of air conditioner unit The user is prohibited from installation by himself Please contact your dealer after buying this machine Professional installation workers will provide installation and test services according t
112. ed while if the status is changed to the indoor ambient temperature will be displayed However the indoor set temperature will be displayed again when the controller receives other remote controls signals Without setting this function the default is the indoor set temperature 14 TIMER OFF TIME OFF can be activated by pressing this button with OFF blinking The method of setting 1s the same as that for TIMER ON 15 TURBO In Cool or Heat mode pressing this button can activate or deactivate this function When this function is on its symbol will be displayed Any change of either mode or fan speed will make this function canceled automatically 16 SLEEP Sleep On and Sleep Off can be selected by pressing this button After powered on the default is Sleep Off After the unit is turned off the Sleep function is canceled When the sleep function is set already the symbol will be displayed And at this time the time of timer can be adjusted Under Fan and Auto modes this function 15 not available 17 LIGHT Light On and Light Off can be set by pressing this button when the unit 15 at On or Off status After powered on the default is Light On 3 2 2 Guide for General Operation 1 After powered on press ON OFF and then the unit will start to run Note when powered off the guide louver of the main unit will close automatically 2 Press MODE to select the desired running mode 3 Press or to set the desired temperatur
113. emperature is 27 DB 19 C WB Outdoor Temperature is 35 The rated heating capacity data is measured under the following work condition Indoor Temperature is 20 C DB Outdoor Temperature is 7 6 CWB b The data will change with the change of products Refer to those parameters listed on nameplate c Noise was tested in semi silenced room so the actual noise value will be a little higher for change of ambient Super Free Match Service Manual 4 2 2 Duct type GFH 09 EA K3D GFH 12 EA K3D GFH 18 EA K3D Model Heat pump NAIA I 2 50 350 50 5 00 Capacity flow volume Sound pressure level H L dB A 37 31 39 32 41 33 Fan motor 3 8 9 52 3 8 b9 52mm 1 2 12 7 Connecting pipe 1 4 6 35 1 4 6 35mm 1 4 6 35 Drain pipe meis mm NaWedwGssdh 2 o 1m _ we 1 wm 9 Loading quantity 234 234 180 7 Super Free Match Service Manual GFHQDEA GDNATAT ml m _ KW 64 1000 1000 Air flow volume E 588 5 BEES 5 Sound pressure level dB A 4384 34 34 Fan motor 5 8 15 9 5 8 15 9 Connecting pipe 3 8 9 52mm 3 8 9 52mm Drain pipe esee oe onmes c ena _ ee
114. en the pump and if the pressure of the pressure vacuum gauge does not rise within 2 hours the system 15 under a vacuum Otherwise the system has leaked please look for where the gas leaks in 6 11 Refrigerant Charging 6 11 1 refrigerant has been charged into the outdoor unit before shipped from the manufacturer while additional refrigerant still need be charged into the refrigerant pipe during the field installation 6 11 2 Calculation of the Additional Refrigerant Charging 1 Get the refrigerant charge of the outdoor unit from the nameplate Note The refrigerant charge of the outdoor unit does not include the charged additionally in the indoor unit BU module and the refrigerant pipe For the length of the connecting pipe is decided on the field the amount of additional refrigerant shall be decided depending on the dimension and the length of the liquid pipe used on the field Record the additional refrigerant charge for future maintenance It does not need to add refrigerant if the total length of liquid pipe is within 30m 2 Calculating the Mass of Additional Refrigerant Additional Refrigerant Charge kg X the Liquid Pipe Length of 6 35 X 0 022kg m the Liquid Pipe Length of 09 52 X 0 054kg m 1 47 kg Ifthe additional refrigerant charge is negative it does not need to add the refrigerant 3 Example GWHD 56S NM3CO Indoor unit 227 2 2 Outdoor unit 3
115. er bracket fixing bolts M6 on the rear side Detach the hanger bracket by pulling it backward Refer to D 3 Set the suspension bolt Use W3 8 M10 size suspension bolts Adjust the distance from the unit to the ceiling slab beforehand Refer to 3 4 Fix the hanger bracket to the suspension bolt Warning Make sure that extended suspension bolt from the ceiling stays inside the arrowed position Readjust the hanger bracket when it is outside the arrowed position Refer to Suspension bolt stays inside the cap of indoor unit Never remove the cap 5 Lift the unit and slide forward unit dent Refer to 6 Screw tightly both hanger bracket setting bolts M8 Refer to 7 Screw tightly both hanger bracket fixing bolts M6 to prevent the movement of the indoor unit Refer to 4 8 Adjust the height so that rear side of the drainpipe slightly inclines to improve drainage Caution Adjust the height by turning the nut with a spanner Insert the spanner from the hanger bracket opening Refer to In case of hanging It is possible to install using inward facing hanger brackets by not removing the brackets from the indoor unit Refer to 8 Be sure to use only the specified accessories and parts for installation work INSTALLATION 093 NOLLISOd 1108 m Super Free Match Service Manual Hanger bracket Hanger bracket setting MES
116. es 5 Bend the pipes to go through the knockout holes 6 Cover the through holes with sealing materials to prevent the water dust or small animals going into the outdoor unit 6 7 Installation of Piping Adapter If the piping connection size of BU module does not match with that of the outdoor unit and indoor units it should prevail with the piping connection size of the outdoor unit and indoor units Install the optional piping adapters to the BU module so that the piping connection size of BU module can match with that of the outdoor unit and indoor units 1 Piping adapter Optional I shape Gam mo 15 9 gt 19 05 15 9 19 05 9 52 gt 12 7 9 52 12 7 3 4953250159 9 52 015 9 4 06 35 09 52 6 35 9 52 2 Install the piping adapter Refer to the piping connection size of the outdoor unit and indoor units the appropriate piping adapter should be adopted 2 Align the flared end of copper tube with the center of pipe joint Tighten the nuts with hands 3 Sealing the unconnected port If the port of BU module indoor side does not connected to one indoor unit the port must be sealed to prevent refrigerant leaks Please tighten the flaring nuts of the unconnected port with torque wrench until you hear a click INSTALLATION BM E Super Free Match Service Manual 6 8 Precaution for Connection 6 8 1 Precaution for connection 1 D 2 2 Pipe connections sho
117. essor stops The compressor stops gradually the outdoor fan stops after 1 min b Some of the indoor units reach the stop condition the compressor does not stop The compressor operates according to the required frequency For the indoor unit with no requirement the corresponding electronic expansion valve is closed to OP 3 Cooling mode transfers to heating mode When the unit transfers to heating mode the 4 way valve is energized after the compressor runs for 40s The other disposals are the same as stopping in cooling mode 4 4 way valve In this mode the 4 way valve is closed 5 Outdoor fan control in cooling mode The outdoor fan starts before 5s of the starting of compressor The outdoor fan will run in high speed for 40s after starting and then it will run in set speed The fan shall run at every speed for at least 80s When the quantity of indoor unit changes the control part will adjust the outdoor fan according to the quantity of indoor unit and outdoor temperature when the compressor stops the outdoor fan runs at present speed and stops after 1 min 2 1 2 Dry Mode 1 The dry conditions and process the same as those in cooling mode 2 status of 4 way valve closed 3 The temperature setting range 16 30 C 4 Protection function the same as those in cooling mode 5 In dry mode the maximum value A of the capacity requirement percentage of single unit 15 90 of that in cooling mode The open conditio
118. essure gear is the fifteenth it will display 15 The range UE UH Heating equalization of the gear is from 0 to 60 MAINTENANCE x6 7 Super Free Match Service Manual If the malfunction occurs in the system the If the malfunction occurs in the outdoor unit section will display the error code If there are the section displays nothing Malfunction several malfunctions it will display the error If the malfunction occurs in the indoor units codes by turns at intervals of 2 seconds the section displays the address of the indoor unit 1 3 Process Control Setting 1 3 1 Button section Caution 1 When entering the menu to set parameters the function section will flash running codes and the data section will flash value 2 When the menu is set the data section will flash After the stops blinking the unit will run the new parameters 1 3 2 Flow chart of operation Initial state Switch with Switch with the the luc kev Hi E yp keys Long press Press Enter acp key for more than ks Press Enter Press Entei 25 P Settings 15 done HN Settings is done AU 5 settings 15 done Settings is done IFO Settings is done Switch with Switch with the key key Press Enter key M ow Low pressure High pressure Note
119. et or any other electric appliances Select a place where the filter can be easily taken out 95 Make sure that the indoor unit installation should accord with installation dimension diagram requirements 4 1 4 Installation and Servicing Space to the ceiling ex ee 15 5 p T above A Space to the wall p NS lt P 4 15cm Above Ecm Above Space to the N2 300cm Above iB Air outlet side opace to the floor E 08 INSTALLATION Super Free Match Service Manual 4 1 5 Installation of Mounting Plate 1 Mounting plate should be installed horizontally As the water drainage pipe for the indoor unit is two way type during installation the indoor unit should slightly slant to water tray s outlet for smooth drainage of condenser water 2 Fix the mounting plate on the selected location with screws 3 Be sure that the mounting plate has been fixed firmly enough to withstand the weight of an adult of 60kg furthermore the weight should be evenly shared by each screw TM T WN on middie Gradienter _ Sito the to the wall wall x 150mm 150 above R amp S Right 55mm Rear piping hole Rear piping hole 4 1 6 Drill piping hole 1 Slant the piping hole 55 70 on the wall slightl
120. eturn type 2 Ifoutdoor unit is below indoor unit it is not needed to install oil trap on the vertical pipe of gas piping 3 If the outdoor unit is below the indoor unit it is not needed to install oil trap at the highest or lowest position If the outdoor unit is above the indoor unit oil trap and stop elbow must be installed at the lowest and highest position of the vertical pipe See the schematics below 4 Fabrication dimension of oil trap is as shown below lt 150 019 05 5 See the schematics below Outdoor unit lower than indoor unit Branch TL Stop elbow __ unit Liquid pipe Outdoor unit INSTALLATION 16 Outdoor unit higher than indoor unit Outdoor unit Stop elbow 6 6 Connection of Outdoor Unit Refrigerant Pipe Inlet air D Inlet air Inlet air Super Free Match Service Manual D Liquid pipe Flare nut Gas pipe 107 INSTALLATION Super Free Match Service Manual Coping plate Rear side plate Front side plate Gas side stop valve Liquid side CAT valve Right connection board Front connection board Unscrew the coping plate front side plate right connection board and front connection board The refrigerant pipes be installed four directions please choose the proper direction 3 Knock the holes in the plate of the chosen direction with the drill and hammer 4 Connect the pipes to the stop valv
121. f defrosting the frequency of the compressor rises to reach the defrosting frequency 5 Olil returned control in heating mode a Oil returned condition The whole unit is operating in low frequency for a long time b Oil returned process in heating mode The indoor unit displays c Oil returned finished condition in heating mode The duration reaches 5min 2 1 4 Fan Mode The compressor the outdoor fan and the 4 way valve are closed temperature setting range 15 16 30 2 2 Protection Function 2 2 1 Mode Conflict Protection of indoor unit When the setting mode 15 different of different indoor unit the unit runs in below status 1 The mode of the first operating indoor unit is the basic mode when compare the mode of the other indoor units to see if there is a conflict Cooling mode dry mode 1s in conflict with heating mode 2 Fan mode is in conflict with heating mode and the heating mode is the basic mode No matter which indoor unit operates first the unit will run in heating mode 2 2 2 Overload Protection Function When the tube temperature is a little low the compressor raises the operation frequency when the tube temperature 15 a little high the compressor frequency is restricted or lows down the operation frequency when the tube temperature is too high the compressor protection stops running If the discharge temperature protection continuously appears for 6 times the compressor can t resume running The
122. f the indoor and the unit will automatically select the suitable operation mode accordance with the room temperature to make indoor room comfortable 5 FAN This button is used for setting Fan Speed in the sequence that goes from AUTO then back to Auto Auto 7 ami mmn Tow speed ov Medium speed Medium speed Medium High 6 SWING Press this button to set up amp down swing angle which circularly changes as below 5 This remote controller is universal If any command or gt is sent out the unit will carry zl commandas 7 2l Tolke 78 indicates the guide louver swings as 7 IFEEL Press this button to turn on I FEEL function The units automatically adjust temperature according to sensed temperature Press this button again to cancel I FEEL function 8 FID Press this button to achieve the on and off of healthy and scavenging functions operation status Press this button for the first time to start scavenging function LCD displays Press the button for the second time to start healthy and scavenging functions simultaneously LCD and Press this button for the third time to quit healthy and scavenging functions simultaneously Press the button for the fourth time to start healthy function LCD display Press this b
123. h frequency facilities exist such as radio equipment electric welder and medical equipment An environment with special conditions 7 Super Free Match Service Manual 3 6 Outline Dimension of the Outdoor Unit ETE THI THH TN It HERT L i i adi HTHRHERHITHHTILLLE cd T o o obe __ a c 1350 TEU RET ELUTE m NETT THAT pcnc 3 7 Installation and Servicing Space 1 When the place of the installation is exposed to strong wind When strong winds of 5 m sec or more exist the place of the installation the outlet of the unit cannot face the wind If the wind blows against the outdoor unit s air outlet it will cause deterioration of the operational capacity and maybe break the fan 2 Incase of installing only one unit In case obstacles exist around the unit the required installation space is in the following figure The unit of the values 15 mm 3 Incase of installing multiple units 2 units or more In case multiple rows of series installation the req
124. he 1 Disconnect the d coping plate coping plate Remove the coping plate Yi 107 ips 22 2 gt A NES Unscrew fixed screw of the 2 Disconnect the front front side plate Lig n WEN P side plate t Remove the front side plate et AS te lt 3 N M 3 2 e lt gt YA viti 7 d 2 A 44 1515 r E 42 1 4 D A a xS ES 3 E HA 0 Unscrew the fixed screws of the 3 Disconnect the outer d 2 outer case case 2 b Remove the outer case MAINTENANCE 7 Super Free Match Service Manual Unscrew the fixed screws of 4 Disconnect the left si left side plate and rear side side plate and rear side i H mel plate plate P Remove left side plate and rear side plate 6 1 2 Assembly and Disassembly of the Compressor Remarks Prior to the assembly of the compressor make sure there is no refrigerant in the pipeline and the power supply is cut off Illustrations Operation Instructions i M un Unscrew the fixed Lable the screws of power color of code power cords b Remove the power and the cord of the terminals NL 1 i i
125. he corresponding function the unit will keep the original running status 3 4 1 Function of Press Buttons 1 ON OFF Press this button to turn on the unit Press this button again to turn off the unit Sleep function will be canceled while unit off 2 MODE Press this button Auto Cool Dry Fan Heat mode can be selected circularly Auto mode is default while powered on Under Auto mode the temperature will not be displayed Under Heat mode the initial value is 28 C 82 Under other modes the initial value is 25 77 3X 6 AUTO COOL DRY SS FAN XX HEAT 3 FAN Press this button Auto Low Medium low Medium Medium high High speed can be circularly selected After powered on Auto fan speed is default Under DRY mode Low fan speed only can be set up Super Free Match Service Manual a a FI dil Tow fan o Medium fan Medium fan fan fan Note It s Low fan speed under Dry mode 4 TEMP Press this button the following temperature can be set circularly the setting temperature indoor ambient temperature and outdoor ambient temperature When the indoor unit firstly power on it will display the setting temperature d If the displaying status is changed to hj displaying the indoor ambient temperature is the outdoor ambient temperature 5s 3s later it will return to the setting temperature or it depends
126. he heat insulation material Heat resistance to 100 C or more Thickness of 9mm or more 3 joints of the system should be wrapped with the heat insulation material and gap 15 allowed on joint of the system as shown the following figure 4 Bundle the refrigerant pipe and transmission line together with tape and separate them from the drain pipe to prevent the condensate water overflowing 5 Wrap the pipe from the bottom of the outdoor unit to the top of the pipe where it enters the wall During the wrapping the later circle should cover half of the former one 6 At intervals of about 1 meter fix the refrigerant pipes to the wall with brackets that is don t let the unit withstand the weight of it or float it in the air Caution After the pipe is protected well enough never bend it to form a small angle 90 otherwise it would crack or break Do not wrap the refrigerant pipes very tight otherwise the insulation effect would be weakened Additionally make sure the drain hose 15 separated from the refrigerant pipes After that cover the hole on the wall with sealing materials to prevent wind and noise going into the room INSTALLATION 7 Super Free Match Service Manual MAINTENANCE MAINTENANCE Super Free Match Service Manual MAINTENANCE 1 Testing Board Introduction The testing board is in the front of electrical box and can be observed well It has seve
127. he weight of the unit The drainage of the drain pipe 15 easy No obstacle 15 the inlet outlet and the air circulation is in good condition Ensure the installation space shown in the following figures 1s left for the access to maintenance It should be far away from where there is heat source leakage of inflammable explosive substances or smog It 15 the ceiling type unit concealed in the ceiling 9 The power cords and connection lines of the indoor and outdoor units must be at least 1m away from the TV set or radio to avoid the image interference and noise even if 1m 15 kept the noise may be produced due to the strong electric wave 2 Installation of the Indoor Unit Insert the M10 expansion bolt into the hole and then knock the nail into the bolt Refer to the Outline Dimension Drawings of the Indoor Unit for the distance between holes and see the following figures for the installation of the expansion bolt 27 Air conditioning unit 7 H CAUTION Prior to the installation please make a good preparation for all piping refrigerant pipe drain pipe and wiring wires of the wired controller wires between the indoor and outdoor unit of the indoor unit to make the further installation much easier Ifthere is an opening in the ceiling it is better to reinforce it to keep it flat and prevent it vibrating INSTALLATION Super Free Match Service
128. ies are complete The power cables shall be separated from communication wires at a least distance of 2cm To avoid breaking the communication wires please do not use strong force For multiple units please mark them properly Switch on the unit and ensure there is no display of Communication Wire Error Each BU module and indoor unit under the same system has a unique address dial code The wired controller and its corresponding indoor unit have the same address dial code Select the remote control mode The centralized controller and communication module shall be installed free from the source of interference The power cable must meet the specifications The PVC pipes must meet the specifications A specific gradient must be provided along the water flow direction Carry out water detection after installation Carry out thermal insulation to the drainage pipe only after the water detection 1s accepted The thermal insulation tube must meet the specifications Seal between the thermal insulation pipes to avoid air entry The copper tube must meet the specifications Ensure it is dry and clean inside the tube Make sure to charge nitrogen as required for protection when welding the tubes Please keep to the welding process and ensure the system free of leakage Adda dual way filter on liquid pipe side For multiple systems please
129. iet setting is the same as the Swing setting b After the setting has been done it has to press the key Enter cancel to back to the setting status or quit automatically five seconds later 7 Sleep Setting Sleep on Press Function under on state of the unit till the unit enters the Sleep setting interface After that press Enter cancel to confirm the setting Sleep off When the Sleep function 15 activated press Function to enter the Sleep setting interface After that press Enter cancel to can this function Sleep off is default after power failure and then power recovery and the sleep functions is unavailable under the fan mode Sleep mode In the Cooling or Dry mode the temperature will increase by 1 after the unit runs under Sleep 1 for 1 hr and 1 C after another Ihr After that the unit will run at this temperature In the Heating mode the temperature will decrease by 1 C after the unit runs under Sleep 1 for 1hr and 1 C after another Ihr After that the unit will run at this temperature Notes a During the above setting 1f Function 15 pressed down or there is not any operation within 5s sleep curve setting will be canceled 7 Super Free Match Service Manual b 26 is the default Sleep curve temperature before delivery The wired controller will automatically memorize the Sleep curve after the setting 8 Turbo Setting Turbo function The unit at the high fan speed can realize quick cooling or heating
130. in Board 1 ossa 1 _ Shield cover of Electric Box 37 0159207301 1 0159207301 1 Sub assy Electric Box Cover 22242135 22242135 Electric Box Assy 20402999 20403018 Cold plasma generator 1114001602 1114001602 pd 4 m m 3 pd 6 8 0 1 3 5 6 8 m Em m Em MotorPressPlate 1 3 4 pd MAINTENANCE Super Free Match Service Manual GWH 18 MC K3DNAJE I Part list GWH 18 MC K3DNA3E I for CB171N08401 NO GWH 18 MC K3DNA3E I escription __1_ ReeivrWindow ______ 22432173 2022 2 _ 4 38 3 1 _ 03 m 6 7 Rear Caseassy ____ 1 4 MAINTENANCE Super Free Match Service Manual 4 0 Gasket sub assy of Bearing 1 _ 16 Remote Contour 1 17 Temperature Sensor Ambient Temperature Sensor Evaporator m Walt Mounting 1 m
131. ing band 6 8 4 The process of install refrigerant pipes QD 2 Remove the screw caps from the pipes Align the flared end of copper tube with the center of pipe joint Tighten the nuts by hands If the flared end of copper tube and the center of pipe joint are not in coaxial it 15 hard to tighten the nuts by hands please do not tighten it with spanners because the screw thread may be broken by force Tighten the flaring nuts with torque wrench until you hear a click The spanner and torque wrench should be perpendicular to the refrigerant pipeline The following table for the torque required to tighten the nuts 7 9 INSTALLATION Super Free Match Service Manual TT Fitting Pipe for 4 6 35 15 30 Nm ndoartUnit Flaring Nuts Fitting Pipe 09 52 mm 35 40 Nm MA 12 7 mm 20 8 mm 45 50 N m CN 015 9 mm 60 65 Nm 37 Pipe diameter Thickness of Tightening torque copper tube 19 05 mm 70 75 Nem During the connection of the indoor unit and BU module to the refrigerant pipe never pull any joints of the indoor unit and the BU module by force otherwise the capillary pipe or other pipe may crack which then would result in leakage The refrigerant pipe should be supported by brackets that is don t let the unit withstand the weight of it For the Super Free Match system each pipe should be labeled to tell which system it belongs to avoid mistaken
132. ional area Recommended cable of indoor unit Pieces Sectional area 4x0 75mm Capacity of the air switch GWHD 56S NM3CO BU module 10A Note The total length of the transmission line between the outdoor unit and the furthest BU module is not more than 55m Otherwise the system cannot work possibility The specifications of the power cable and transmission line listed in the table above are determined based on the maximum power maximum amps of the unit The specifications of the power cable listed in the table above are applied to the conduit guarded multi wire copper cable like YJV copper cable consisting of PE insulated wires and a PVC cable jacket used at 40 C and resistible to 90 and shall be at least those of ordinary polychloroprene sheathed cords code designation 60245 IEC 57 If the working condition changes they should be modified according to the related national standard The specifications of the air switch listed in the table above are applied to the breaker with the working temperature at 40 If the working condition changes they should be modified according to the related national standard Thelength of the recommended power cable should be less than 15 meters otherwise the diameter of the power cable is not enough Mentioned power cable and transmission line length is just a reference value It may be different depending on the condition of installation humidity or materials etc
133. ired controller after power Super Free Match Service Manual failure will resume its original running state upon power recovery Memory contents On Off Mode set temperature set fan speed Save function and Lock function Enquiry of the Outdoor Ambient Temperature Under the or state of the unit press Enter Cancel for 5s and the outdoor ambient temperature will be displayed after a sound of click This enquiry state will quit by pressing Function or On Off or during the temperature adjustment If there is not any operation for 10s it will also quit automatically 3 1 4 Errors If there 15 an error occurring during the operation of the system the error code will be displayed on the LCD If multi errors occur at the same time their codes will be displayed circularly Note In event of any error please turn off the unit and contact the professionally skilled personnel Em Ense cancel amp Fan m Super Free Match Service Manual 3 2 Wireless Remote Controller YT1F MOTO Notes a Be sure that there are no obstructions between the receiver and the remote controller b Do not drop or throw the remote controller c Do not let any liquid into the remote controller and expose the remote controller to direct sunlight or any place where is very hot d This 15 a general use remote controller If press some button which 15 not available for the corresponding function
134. istance with no connection If it is unavoidable please make sure the connection should be reliable and the external forces will not act on the wires Otherwise it will cause electrical shock or fire etc When erecting or relocating the air conditioner do not let any air enter into cooling circulation system except the specified refrigerant If any air 1s mixed abnormal high pressure will occur in the cooling circulation system thus causing crack or human injury accidents 768 INSTALLATION Super Free Match Service Manual Do not use or store flammable explosive poisonous or other dangerous substances beside the air conditioner When installing or relocating the unit Please contact the appointed service center or the professional installation personnel for the repair or relocation of the unit The compressor will vibrate sharply if the voltage 15 too low and damage the refrigerating system Electrical component are easy to damage if the voltage is too high The voltage should be stable there shouldn t be big fluctuation Please take notice of the installation foundation of the unit after long use if it is damaged it may lead to the fall of the unit and cause the injury The refrigerant pipes and accessories must be designed exclusively for R410A Before installation please check that whether the power supply corresponds with the requirement specified on the nameplate and also check its security Before using the unit
135. l component 3 Replace the new Install the new 4 way 4 way valve valve Say Solder the 4 TERN Solder the connecting m Pis fourjomts pipes 4 Solder the new 4 way Note To avoid heat valve and install the damage the internal magnet coil structure of the 4 way wrap it to be brazed with sufficient wet cloths MAINTENANCE Super Free Match Service Manual 6 2 Indoor unit 6 2 1 Wall mounted type Removal and Assembly of Fan Motor Remark Prior to the assembly of the motor make sure the power supply 1s cut off x E Loosen the screws Unplug the motor Remove the front terminals in the panel front case and LQ 7 electric box ANC a pum OS SLL A 21 electric box Loosen X the earth screws and lift up Unscrew the fixed screws 2 Remove the evaporator of the evaporator and then remove it fixed screws of the motor Unscrew the press plate and cross 3 Remove the motor and flow fan cross flow fan Separate the motor from the cross flow fan MAINTENANCE Super Free Match Service Manual 6 2 2 Ducted type Removal and Assembly of Fan Motor Remark Prior to the assembly of the motor make sure the power supply 15 cut off Illustrations Operation Instruction
136. left amp right swing Sleep mode HEALTH SAVE F ul i 1 Up amp down swing E Indoor ambient temp CN Outdoor ambient temp SLEEP LIGHT Y 1 ON OFF Press this button can turn on or turn off the air conditioner After turning on the unit operation indicator WO on indoor unit is ON green indicator Color may be different for different models and indoor unit gives out a sound 2 MODE Press this button Auto Cool Dry Fan Heat mode can be selected circularly AUTO COOL DRY FAN HEAT gt f gt After selecting auto mode air conditioner will operate automatically according to ambient temperature Set temperature can t be adjusted and also can t be displayed Press FAN button can adjust fan speed Super Free Match Service Manual d Press gt button and FA button can adjust swing angle 5 ang After selecting cool mode air conditioner operates under cool mode Cool indicator on indoor unit is ON You can press or button to adjust set temperature Press FAN button can adjust gt fan speed Press 7 button 1 button can adjust swing angle 5 After selecting dry mode air conditioner operates under dry mode at low speed Dry indicator 6 indoor unit is ON Under dry mode fan speed can t be adjusted Press 7 button 1
137. links 00 00 is displayed for ON time setting Within 5 seconds press or button to adjust the time value Every press of either button changes the time setting by 1 minute Holding down either button rapidly changes the time setting by 1 minute and then 10 minutes Within 5 Seconds after setting press TIMER ON button to confirm Press T OFF button to initiate the auto off timer To cancel the auto timer program simply press the button again TIMER OFF setting is the same as TIMER ON 14 TURBO Press this button to activate deactivate the Turbo function which enables the unit to reach the preset temperature in the shortest time In COOL mode the unit will blow strong cooling air at super high fan speed In HEAT mode the unit will blow strong heating air at super high fan speed 15 LIGHT Press LIGHT button to turn on the display s light and press this button again to turn off the display s light If the light is turned on is displayed If the light is turned off disappears 16 X FAN Pressing X FAN button in COOL or DRY mode the icon displayed and the indoor fan will continue operation for 10 minutes in order to dry the indoor unit even though you have turned off the unit After energization X FAN OFF is defaulted X FAN is not available in AUTO FAN or HEAT mode 3 3 2 Guide for General Operation 1 Combination of and buttons About lock Press and buttons simultaneously to lock or unlock the keypad If
138. llation should be left to the appointed service center Please contact your dealer after purchasing this machine Professional installation workers will provide installation and test services according to the installation manual The air conditioner should not install in this place where the small animals exist because they may cause malfunctions smoke or fire Please keep the area around the unit clean The outdoor unit must be installed on a firm and solid support which can withstand the weight and the mounting surface must be horizontal plane There 15 enough space for the installation and maintenance The place should be well ventilated so the machine can absorb and discharge sufficient air Outdoor unit shall be installed close to the indoor unit hence to minimize the length and bends of cooling pipe Avoid place the outdoor unit under the windows or between the constructions hence to prevent normal operating noise from entering the room Do not install in the place where there is flammable or explosive gas exist or a place subject to severe dust salty fog and polluted air Installation at the following places might lead to the air conditioner malfunction If it 1 unavoidable please contact the appointed service center INSTALLATION A place which 15 full of machine oil A region with saline sodic soil near the sea A place where the sulphide fog exists such as the sulphur spring A place where the hig
139. lower of the hoisting stand to fix it The use of gasket anchor board can prevent gasket break off Use install cardboard Please refer to the install cardboard about the dimension of ceiling opening The central mark of the ceiling opening is marked on the install cardboard Install the install cardboard on the unit by bolt 3 piece and fix the angle of the drainage pipe at the outlet vent by 3 Adjust the unit to the suitable install place 4 Check if the unit 15 horizontal Inner drainage pump and bobber switch are included in the indoor unit check if 4 angle of every unit are horizontal by water lever If the unit is slant toward the opposite of the coagulate water flow there may be malfunction of the bobber switch and lead water drop 5 Backout the gasket anchor board used to prevent gasket break off and tighten the nut on it INSTALLATION Super Free Match Service Manual 6 the install cardboard Nut supplied at scene Gasket attachment ZA stand 7 i Tighten double nuts attachment Fix the hoisting stand firmly Fix the gasket firmly Bolt of one of the angle of pipe 1s fix on the angle of the drainage slot Install cardboard Water lever Polyethylene pipe Bolt attachment _ Fix the install cardboard Bolt attachmeno Note Please do tighten the nuts and bolts to prevent air conditioner break off 4
140. m please make sure to take measures to prevent that the refrigerant will not exceed the limit concentration in case of leakage For the measures to prevent the refrigerant from exceeding the limit concentration please consult your dealer If no proper measures it might cause human suffocation 1 case of refrigerant leakage Please install the unit on a solid place where is strong enough to support the weight of the unit Otherwise the unit would fall down and cause injury or death Electrical work should be carried out in accordance with the installation manual and the local laws and regulations Insufficient capacity or incomplete electrical work may cause electrical shock or fire etc Please use suitable cables and connect them securely Please fix the terminal joints securely The terminal connection shall not be affected due to any external force applied onto the cable Improper connection and fixing may cause heating and fire accidents The power supply must adopt the special circuit with air switch protection and assure it has enough capacity The unit will be turned on or off according to your requirement automatically please do not turn on or off the unit frequently Otherwise disadvantage effect may be caused to the unit Never cut off or damage power cables and control wires If the power cable and signal control wire were damaged change them by professional The electrical work should use a cable length enough to cover the entire d
141. maintained after 7hours the temperature will be decreased 1 after that the unit will keep on running under this temperature 4 When setting the initial temperature 30 under this temperature setting after 7hours the temperature will be decreased 1 after that the unit will keep on running under this temperature In Heat mode 1 Under the initial presetting temperature 16 C it will run under this setting temperature all along Under the initial presetting temperaturel7 C 20 after Sleep function started up the temperature will decrease 1 in every hour after 1 decreased this temperature will be maintained 2 3 Under the initial presetting temperature 21 C 27 C after Sleep function started up the temperature will decrease in every hour after 2 decreased this temperature will be maintained Under the initial presetting temperature 28 30 after Sleep function started up the temperature Super Free Match Service Manual will decrease in every hour after 3 decreased this temperature will be maintained Sleep 3 the sleep curve setting under Sleep mode by DIY Under Sleep 3 mode press Turbo button for a long time remote control enters into user individuation sleep setting status at this time the time of remote control will display 1hour 2 Adjust and button could change the corresponding setting temperature after adjusted press Trubo bu
142. mode indoor fan operates at auto quiet mode according to actual cooling heating or Super Free Match Service Manual fan mode About Sleep function Under the Fan and Auto mode the Sleep function cannot be set up under Dehumidify mode only Sleep 1 can be selected Select and enter into any kind of Sleep mode the Quiet function will be attached and stared different Quiet status could be optional and turned off 3 5 Wireless Remote Controller YB1F2 XFAN Notes a Be sure that there are no obstructions between the receiver and the remote controller b Do not drop or throw the remote controller c Do not let any liquid into the remote controller and expose the remote controller to direct sunlight or any place where is very hot d This is only use for change indoor unit If press some button which is not available for the corresponding function the unit will keep the original running status 3 5 1 Function of Press Buttons AIR HEALTH X FAN UE EP F HOUR ON OFF fan speed FAN AUTO mode _ signal Operation mode SN SEAN health mode Auto mode X fan Cool 4 Dry mode 4 set temperature 1 mode Heat mode deum s 23 HOUR TIMER ON TIMER OFF 1 _ set time a
143. more 60cm or more 30cm or more 60cm or more 100cm or more 4 2 Important notice The unit must be installed by the professional personnel according to this install instruction to ensure the well use Please contact the local Gree special nominated repair department before installation Any malfunction caused by the unit that 1s installed by the department that is not special nominated by Gree would not deal with on time by the inconvenience of the business contact Itshould be done by professional personnel when the air conditioner unit is moved to other place 4 4 6 There are 2 styles of installation Ceiling type and Floor type Each type 15 similar to the other as follows 1 Determine the mounting position on ceiling or wall by using paper pattern to indicate indoor frame Mark the pattern and pull out the paper pattern Refer to D Side panel fixing screw MA Installation paper plank 2 Remove the return grill the side panel and the hanger bracket from the indoor unit as per procedure bellow Super Free Match Service Manual Press the fixing knob of the air intake grills the grilles will be opened wider and then pull them out from the indoor Remove the side panel fixing screw and pull to the front direction arrow direction to remove Side panel fixing screw Refer to Loosen two hanger bracket setting bolts M8 on each side for less than 10mm Remove two hang
144. motor E mE 3 8 9 52mm 3 8 9 52mm 1 2 12 7mm Connectin dia ee 35mm 35mm 35mm Connection method Flare Connection _ Connection F Flare Connection Connection Flare Connection _ Connection External Drain pipe Thickness Outline WxDxH 700 215 600 700 215 600 700 215 600 dimension Package WxDxH mm 791 286 710 791 286 710 791 286 710 dimension Capacity Pipe Notes a The rated cooling capacity data is measured under the following work condition Indoor Temperature is 27 C 19 C WB Outdoor Temperature is 35 The rated heating capacity data is measured under the following work condition Indoor Temperature is 20 C DB Outdoor Temperature is 7 6 C WB b The data will change with the change of products Refer to those parameters listed on nameplate Noise was tested 1 semi silenced room so the actual noise value will be a little higher for change of ambient Super Free Match Service Manual 4 3 Product Data of BU Module Maximum numbers of connectable indoor units Power Supply V Ph Hz 220 240 1 50 Gas pipe inner diameter 15 9 15 9 Liquid pipe inner diameter Connection port to outdoor unit Connection Method Gas pipe inner diameter mm 9 52 9 52 Connection port to indoor unit Liquid pipe inner a mm 06 35 635 35 a a Drainage pipe Net weight Gross weight 8 10 9 11 Note
145. mstances as the following that where there is full of mist of oil corrosive gas flammable gases the acidic or alkaline vapor and the ocean Once started the air conditioner shall not be stopped at least after 5 minutes or longer otherwise its service life the unit will be shortened Do not let the children operate the air conditioner Never operate the unit with wet hands Otherwise it may cause electric shock Before cleaning and repairing it is necessary to stop working and turn off the power supply Otherwise it may cause electric shock or damage It is suggested to have a power on test annually INSTALLATION 1 2 Key Points of Installation Super Free Match Service Manual Installation Procedures Description and Acceptance Criteria Material Selection and Equipment Inspection The materials specified on the engineering drawing shall be purchased as specified e g copper tube thermal insulation tube PVC pipe power cables air switch etc The materials not specified on the engineering drawing shall be purchased according to the actual quantity of works e g hanger frame cable duct etc Check if the outdoor unit indoor unit BU modules Connection Communic ation wire Address dial code Installation of indoor unit Remote Control Installation Drainage Pipe Thermal insulation Installation of connection Welding pipes communication wires and accessor
146. n O hour 3 Under the clock setting status it 15 used to set the hour max 23 min 0 and minute max 59 min 0 of the clock m Mon 1 9 It is used for the switchover between unit 1 and unit 9 Under the timing or clock setting status it indicates Monday It is used for the switchover between unit 2 and unit 10 Under the timing or clock setting status it indicates Tuesday It is used for the switchover between unit 3 and unit 11 Under the timing or clock setting status it indicates Wednesday It is used for the switchover between unit 4 and unit 12 Under the timing or clock setting status it indicates Thursday Fri 5 13 It is used for the switchover between unit 5 and unit 13 Under the timing or clock setting status it indicates Friday T sat 6 14 It is used for the switchover between unit 6 and unit 14 Under the timing or clock setting status it indicates Saturday sun 7 15 It is used for the switchover between unit 7 and unit 15 Under the timing or clock setting status it indicates Sunday 8 16 It is used for the switchover between unit 8 and unit 16 It is used to set the timing or on off time of the selected indoor unit as well as to set the 14 Timer Time clock of the system It is used for the switchover between single and centralized control modes Shield It is used to deactivate some or all functions of a single or a group the indoor unit s All off It is used to start stop all
147. n again 2s later Istatus will switch to off status directly if press this button again within 25 the change of swing status will also depend on the circulation sequence stated above About switch between Fahrenheit and Centigrade Under status of unit off press MODE and buttons simultaneously to switch and Combination of TEMP and CLOCK buttons About Energy saving Function Press TEMP and CLOCK simultaneously in COOL mode to start energy saving function Nixietube displays SE Repeat the operation to quit the function Combination of TEMP and CLOCK buttons About 8 C Heating Function Press TEMP and CLOCK simultaneously in HEAT mode to start 8 Heating Function Nixie tube on the remote controller displays 46 and a selected temperature of 8 46 if Fahrenheit is adopted Repeat the operation to quit the function About Quiet function When quiet function is selected 1 Under cooling mode indoor fan operates at notch 4 speed 10 minutes later or when indoor ambient temperature lt 28 indoor fan will operate at notch 2 speed or quiet mode according to the comparison between indoor ambient temperature and set temperature 2 Under heating mode indoor fan operates at notch 3 speed or quiet mode according to the comparison between indoor ambient temperature and set temperature Under dry fan mode indoor fan operates at quiet mode Under auto
148. n of the electronic expansion valve outdoor fan and compressor 15 the same as those in cooling mode 2 1 3 Heating Mode 1 Heating conditions and process When one of the indoor units reaches the heating operation condition the unit starts heating operation 2 Stop in heating operation a When all the indoor units reach the stop condition the compressor stops and the outdoor fan stops after 1 min b Some of the indoor units reach the stop condition The compressor reduces the frequency immediately and operates according to the required frequency c Heating mode transfers to cooling mode dry mode fan mode The compressor stops The outdoor fan stops after 1 min 7 Super Free Match Service Manual The status of 4 way valve energized 3 Outdoor fan control in heating mode The outdoor fan starts before 5s of the starting of compressor and then it will run in high speed for 40s The fan shall run at every speed for at least 80s When the compressor stops the outdoor fan stops after min 4 Defrosting function When the defrosting condition is met the frequency of the compressor starts to decrease and wait for defrosting the electronic expansion valve of all indoor units open in big angle the outdoor fan stops after the stop of the 4 way valve meanwhile the 4 way valve reverses the direction after the 4 way valve reverses the direction the frequency of the compressor starts to rise then begin to calculate the time o
149. o installation manual Do not connect to power until all installation work is completed 4 4 2 Selection of Installation Location Such a place where cool air can be distributed throughout the room Such a place where is condensation water is easily drained out Such a place that can handle the weight of indoor unit Such a place which has easy access for maintenance Such a place where is permitting easy connection with the outdoor unit Such a place where is 1m or more away from other electric appliances such as television audio etc Avoid a location where there is heat source high humidity or inflammable gas Do not use the unit in the immediate surroundings of a laundry a bath a shower or a swimming pool 9 Be sure that the installation conforms to the installation dimension diagram 4 4 3 Caution for installation where air conditioner trouble is likely to occur Where there is too much of oil Where it is acid base area Where there is irregular electrical supply 4 4 4 Outline Dimension Drawings of the Indoor Unit When installing the indoor unit you can refer the paper pattern for installation and make sure that the drainage side must be 10mm lower than the other side in order to drain the condensation water fluently INSTALLATION Super Free Match Service Manual 4 4 5 Installation and Servicing Space 1 The space around the unit is adequate for ventilation 150cm or
150. omg 1 1 Retwhiesng 4 1 Rearsideplateasy 5 CmW glhn 4 n spen i15 AWemd ___ 2 16 A fright Coverite 1 1s 19 conection Bord 0 3 a Rear Connecting Pats ooa 1 m RaMwr 1 3 Tis i ___ 3 4 36 GbeGmwlep 1 x3 3 3 Y 3 _____ itn 36 1 3 39 1 49 3 41 1 49 installation Supporting Fame 1 0 DihyBmd 46 1 at E T 1 5 MAINTENANCE p
151. ompressor will enter high pressure protection as it stops when reaching set temperature Meanwhile the outdoor unit will send the signal of high pressure protection to the indoor units 2 After the appearance of high pressure protection the compressor can resume running only after cutting off the power and then putting through the power 2 2 6 Compressor low pressure protection 1 Low Pressure Protection for Shutdown a After the compressor stops for five minutes if it is detected that the low pressure protection is work then a low pressure protection signal will be send out b If it 1s detected continuously for three seconds that the low pressure protection is work after the compressor stops for less than five minutes then a low pressure protection signal will be send out However if the low pressure protection occurs twice in one hour then it becomes unrecoverable and has to be recovered by powering the outdoor unit again 2 Low Pressure Protection during the Operation a When it is detected continuously for three seconds that the low pressure protection 15 work then the whole unit should be shut off and a low pressure protection signal should be sent to the indoor unit b On condition that a low pressure protection error occurs and the whole unit has stopped for more than three minutes and it is detected continuously for six seconds that the low pressure protection switch 15 closed then this error can be eliminated However
152. on Enter cancel 2 Press it 5s to examine the outdoor ambient temperature Running temperature setting of the indoor unit range 16 30 2 2 Timer setting range 0 5 24 hr he peak T moonen Press them for 5s under off state of the unit to enter cancel the Memory function If memory is set indoor unit after power failure and then power recovery will resume the 4 2 A Mode a original setting state If not the indoor unit is defaulted to be off after power recovery Memory off is default before delivery By pressing them at the same time under off state of the unit Ed will be displayed on the wired remote controller for the cooling only unit while E will be displayed on the wired remote controller for the cooling and heating unit Upon startup of the unit without malfunction or under off state of the unit press them at 2 6 the same time for 5s to enter the lock state in which case any other buttons won t respond the press Repress them for 5s to quit this state Super Free Match E Service Manual 3 1 3 Operation Instructions 1 On Off Press On Off to turn on the unit and turn it off by another press 2 Mode Setting Under the On state of the unit press Mode to switch the operation modes as the following sequence Cooling Dry Fan Heating 3 Temperature Setting Press or V to increase decrease the preset temperatu
153. on the other received signal within 5s 3s Note Outdoor ambient temperature display range is 0 60 32 99 As for the outdoor ambient temperature below 0 it displays 0 C 32 F function is applicable to partial of models Warm tips When operating buttons on the cover please make sure the cover is closed completely 5 CLOCK Press this button the clock can be set up signal blink and display Within 5 seconds the value can be adjusted by pressing or button if continuously press this button for 2 seconds above in every 0 5seconds the value on ten place of Minute will be increased 1 During blinking repress the Clock button or Confirm button signal will be constantly displayed and it denotes the setting succeeded After powered on 12 00 is defaulted to display and signal will be displayed If there 15 signal be displayed that denotes the current time value is Clock value otherwise is Timer value 6 LIGHT Press LIGHT button at unit On or Off status Light On and Light Off can be set up After powered on Light On is defaulted 7 TURBO Under Cool or Heat mode press this button can turn on or turn off the Turbo function After the Turbo function turned on the signal of Turbo will display The signal will be automatically cancelled if changing the mode or fan speed 8 Pressing X FAN button in COOL or DRY mode the icon Ris displayed and the indoor fan will continue operation
154. or unit including on off running mode fan speed etc and also perform the single control and centralized control further it also can set the weekly timer and long distance shielding to realize convenient control to the air conditioning system a Single control it is intended to control the running parameters of a designated indoor unit individually b Centralized control 1 is intended to control the running parameters of all indoor units at the same time Shielding under single or centralized control 1 15 intended to shield the running parameter of the indoor unit d Weekly timer under single or centralized control it is intended to set when to start stop the unit through long distance control e Clock it 1s intended to set and display the weekday hour and minute After the debugging to the controller 15 finished it can check the on line indoor units and display the parameter setting of the current running mode set temperature fan speed weekly timer shielding function etc When some error occurs the error symbol and the error code will be displayed to warn a quick maintenance This smart zone controller can be connected to the unit through the communication line without the need of the communication module which can extremely ease and simplify the installation 4 1 2 Scope of application The smart zone controller cannot be adapted to all kinds of indoor units and the wired remote controller must be used in the indoor unit
155. ort assembly and circle the air sweeping motor joint Remove the water tray Remove the evaporator ea Di p Remove the screws as shown by the arrow in the Remove the graph There are 6 screws evaporator on left and right of the evaporator and 5 on evaporator outlet press plate modules MAINTENANCE amo Super Free Match Service Manual Remove fixing plate sub assy for air sweeping fans Illustrations Operation Instructions Remove fixing plate Remove the screws shown sub assy for air l in the graph sweeping fans Remove fan and motor components Illustrations Operation Instructions eee Press the buckle at the joints of front and back scroll cases with hands and pull upward to remove the front scroll case Then remove the screws on the back scroll case Lift the buckle of back scroll case with 1 Remove front and back scroll cases hands and remove it As 1s shown in the graph circle represents 2 screws on left and right Remove the fixed screws of fan wheel with inner hexagonal and remove the 2 Remove fans wheel The inner hexagonal and its direction of effect are shown by the arrow in the graph Remove 4 screws on the 3 Remove bearing bearing fixing plates with fixing plates EA screwdriver As shown in box in the graph 7 0 MAINTENANCE Service Manual 7 EXPLODED VIEWS AND PART LIST Super Free Ma
156. os use 283 18 s se ose oss x 295 197 sso 096 0 29 196 _ o 4me im 769 _ 47 355 235 s x 154 108 5 368 244 _ x30 5 360 249 _ 151 MAINTENANCE Super Free Match Service Manual buco Resistance Voltage Voltage T Resistance Voltage Voltage 6 3579 4 097 2 664 2998 4167 23750 63 2922 4 091 2 700 68 2191 4 214 2 781 ur m 3 217 4 117 2717 69 2 702 4 237 2 796 3 105 4 143 2734 70 261 4 259 2 811 5 2 20 Resistance Voltage Voltage Temp Resistance Voltage Voltage kQ 15 5 15K 3 3V CC 15 5 15K 3 3V s ow 202 ou 028 6 098 3 em ew is m 0 05 108 9 as oso 2 239 157 29 245 164 s 096 095 255 1556 v es 1m erm 3 m 197 MAINTENANCE am Temp CO EJ Super Free Match Service Manual Temp Resistance Voltage Voltage Temp Resistance Voltage Voltage c m 3V 3V 1359 2977 1965 5942 3 855 254 13 04 3 027 1 998 5 726 3 887 2 565 36 12
157. ough all the room Make sure that the installation had accord with the requirement of the schematic diagram of installation spaces Select the place where can stand 4 times of the weight of the indoor unit and would not increase the operating noise and oscillate The horizontally of the installation place should be guaranteed Select the place where easy drains condensate water and easy connects with outdoor unit Make sure that there are enough space for care and maintenance Make sure that the weight between the indoor unit and ground is above 1800mm When installing the hanger bolts check if the install place can stand the weight 4 times of the unit s If not reinforce before installation Refer to the install cardboard and find where should be reinforced There will be lots of lampblack and dust stick on the top heat exchanger and water pump in dining room and kitchen which would reduce the capacity of heat exchanger lead water leakage and abnormal operation of the water pump The following treatment should be taken under this circumstance Ensure that the smoke trap above cooker has enough capacity to obviate lampblack to prevent the indraft of the lampblack by the air conditioner Keep the air conditioner far from the kitchen so that the lampblack would not be indraft by the air conditioner Important notice INSTALLATION To guarantee good performance unit must be installed b
158. ower supply of the outdoor unit and all the BU modules should be separately The electrical work should use a cable length enough to cover the entire distance with no connection If it is unavoidable please make sure the connection should be reliable the external forces will not act on the wires and the joint is not bared Otherwise it will cause electrical shock or fire etc The power cable with the rated voltage and exclusive circuit for the air conditioning should be used Do not pull the power cable by force after it 15 installed The diameter of the power cable should be large enough and once it is damaged it must be replaced by the dedicated one 7 5 Precaution of Laying Wires 1 2 3 4 Use a wire stripper to strip off about 25mm of the insulation layer at the end of the wires Loosen the screws on the terminal block of the air conditioner Use the pliers to bend the end of the wire into a ring shape corresponding the size of the screw Pass the screw through the wire ring and fix it onto the terminal block Insulation layer 7 6 Electrical Wiring Work for Outdoor Unit 1 Knock holes in the plate of the chosen direction with the hammer 2 Place the rubber ring on the knockout hole 3 Letthe power cable and transmission line go through the knockout hole 4 Connect the power cable of the outdoor unit to the L1 L2 L3 N terminals and as well as the ground screw 5 Connect the transmission line of the outdoo
159. ponding setting temperature after adjusted press Turbo button for confirmation 3 At this time 1 hour will be automatically increased at the timer position on the remote control that are 2 hours or 3 hours or 8 hours the place of setting temperature 88 will display corresponding temperature of last setting sleep curve and blink 4 Repeat the above step 2 3 operation until 8 hours temperature setting finished sleep curve setting finished at this time the remote control will resume the original timer display temperature display will resume to original setting temperature Sleep3 the sleep curve setting under SLEEP mode by DIY could be inquired The user could accord to sleep curve setting method to inquire the presetting sleep curve enter into user individuation sleep setting status but do not change the temperature press Turbo button directly for confirmation Note In the above presetting or enquiry procedure if continuously within 10s there 15 no button pressed the sleep curve setting within 10s there 15 no button pressed the sleep curve setting status will be automatically quit and resume to display the original displaying In the presetting or enquiry procedure press ON OFF button Mode button Timer button or Sleep button the sleep curve setting or enquiry status will quit similarly 10 TEMP Press this button could select displaying the indoor setting temperature or indoor ambien
160. quid state Please prevent the refrigerant leakage from your body when remove the charging hose Please heat the refrigerant tank with hot water hot air when the outside temperature is too low However it must be forbidden to heat with fire directly otherwise 1 may lead to explosion INSTALLATION Super Free Match Service Manual 7 Electrical Wiring Work 7 1 Wiring Connection Precept 1 Outdoor unit 1 D POWER L1 L2 L3 N Outdoor uit L 2 Outdoor BU module module Power T2 oor u il Indoor unit Indoorunit Indoor unit Indoor unit Indoor unit Indoor unit Indoorunit Indoor unit LA 1B 1 1 2B 1C Precept 2 Outdoor unit POWER power BU module GPE Outdoor unit 2 BU module 213 213 Se Ls Indoor unit Indoor unit Indoor unit Indoorunit Indoor unit Indoor unit Indoor unit Indoor unit 10 2B 2C INSTALLATION Super Free Match Service Manual 7 2 Requirements of Power Circuit and Cable Phase and frequency 3Ph 50Hz Voltage 380 415V Recommended cable of outdoor unit GWHD 48S NM3CO Pieces x Sectional area GWHD 56S NM3CO Recommended cable of BU module Pieces Sectional area 3 0 75 mm Transmission line Pieces x Sect
161. r unit 1s 1t run swing louver of indoor unit is it completely open Check the indoor outdoor filter and hea exchange fin 1s there filt blockage NO Yes No Replace the outdoor unit mainboard Check the low pressure sensor is Yes Replace the low pressure sensor it normal Charge refrigerant according to the amount specified in the nameplate and calculated additional amount Refer to Instruction Manual of indoor unit N Completely open the valve Close the panel No Remove the barrier Measure the fan motor and signal input No Measure swing motor and signal input Refer to Care and Maintenance No Refrigerant pipe is blocked gt Mainly check the inlet and outlet of main pipe connecting with each indoor unit and capillary of indoor and outdoor units Replace the parts like filter capillary and so on MAINTENANCE 7 Super Free Match Service Manual 3 3 Malfunction display Discharge temperature protection Discharge temperature protection Measure discharge 0 it alee 2 5 A d 125 C temperature sensor 1 it unit mainboard 2 correct 50K 9 Yes No Replace relevant discharge temperature sensor Are the Yes Replace relevant
162. r between the main board and driving board Communication error between the main board and NE Uo ro T board Gas sensor error error of indoor unit indoor unit Jumper terminal error of indoor unit Tai BU module BUlkcmwad o BUsicmmeed _ imMerwiAiemedd 777 3 1 indoor unit Cis connected mehan Indoor unit A gas tube temperature EE indoor Flash 1 time sensor error unit address Indoor unit A liquid tube b5 indoor Flash 2 times b5 temperature sensor error unit address Indoor unit B gas tube temperature b7 indoor Flash 3 times b7 unit address Indoor unit B liquid tube b5 indoor Flash 4 times b5 temperature sensor error unit address Indoor unit C gas tube temperature b7 indoor Flash 5 times b7 unit address Indoor unit C liquid tube b5 indoor Flash 6 times b5 temperature sensor error unit address Indoor unit D gas tube temperature b7 indoor Flash 7 times b7 unit address 155 MAINTENANCE Super Free Match Service Manual Indoor unit D liquid tube b5 indoor Flash 8 times b5 temperature sensor error unit addre
163. r unit to the 2 terminals 6 Fixthe power cable and transmission line firmly by cable fixing clip 7 Screw the coping plate front side plate right connection board front connection board back 8 Cover the through holes with sealing materials to prevent the water dust or small animals going into the outdoor unit Caution The transmission line and the power cable must be separated and separated with an interval of at least 2cm otherwise it may be result in communication problem In order to protect the power cable and transmission line from damaging by the hole the rubber ring must be placed on the hole Otherwise it may cause electrical shock or fire etc The power wire and transmission line must be more than one meter away from televisions or radios INSTALLATION which can emit electromagnetic waves to prevent image interference noise Otherwise the unit maybe cannot work Super Free Match Service Manual Confirm the each cable connected to the terminal screw is exactly and securely after finishing the electric work Fix each ground wire separately with the ground screw If the connecting wire is connected to the terminal incorrectly the unit will not work normally 7 7 Electrical Wiring Work for BU Module 1 Unscrew the electrical equipment plate 2 The structure of behind the electrical equipment plate BRR RE 2 aa 0000000000 T NI j
164. ral following advantages Automatically detect indoor unit numbers Automatically assign indoor unit addresses Automatically display real running function and error code Option settings to suit the demand of the customer 11 Compose of Testing Board The testing board is composed of the function section data section and button section 1 2 Instruction of Function and Data Section Running m The display of function section The display of data section state 1 The section will display the numbers of the D If the function section displays the numbers of indoor units which M have established the indoor units the data section will display the communication with the outdoor unit For outside temperature For example the 35 15 example if there are seven established represented of 35 Stop indoor units the section will display 7 MEN If the function section displays the address of It will display the address of the indoor the indoor unit the data section will display the units by turns For example the 16 is model of the indoor unit for example the 35 represented of the indoor unit 1B BU module 1 2 3 Indoor unit A B C is represented of 35 model The code of running state Cods Running It ee gear of the compressor If state the gear 15 zero it will display 0 For example the Normal Pr
165. rature as soon as possible Super Free Match Service Manual 3 3 Wireless Remote Controller 1 Notes a Be sure that there are no obstructions between the receiver and the remote controller b Do not drop or throw the remote controller c Do not let any liquid into the remote controller and expose the remote controller to direct sunlight or any place where is very hot d It is only use for U Cool and Console type indoor units If press some button which 1s not available for the corresponding function the unit will keep the original running status 3 3 1 Function of Press Buttons dran damos LIGHT 1 ON OFF Press this button to turn on the unit Press this button again to turn off the unit 2 Press this button to decrease set temperature Holding it down above 2 seconds rapidly decreases set temperature In AUTO mode set temperature is not adjustable Press this button to increase set temperature Holding it down above 2 seconds rapidly increases set temperature In AUTO mode set temperature is not adjustable 4 MODE Each time you press this button a mode 15 selected COOL DRY FAN and HEAT as the following AUTO cooL DRY FAM Lo Note Only for models with heating function After energization AUTO mode is defaulted In AUTO mode the set temperature will not be displayed on Super Free Match Service Manual the LED o
166. re If press either of them continuously the temperature will be increased or decreased by every 0 55 In the Cooling Dry or Heating mode the temperature setting range is 16 30 In the Fan mode the setting temperature is fixed at 26 In the Auto mode the setting temperature is unadjustable 4 Fan Setting Under the state of the unit press Fan and then fan speed of the indoor unit will change circularly 5 Timer Setting Under the On Off state of the unit press Timer to set timer off on Timer on setting press Timer and then LCD will display xx x hour with hour blinking In this case press A or to adjust the timing value Then press Enter cancel to confirm the setting Timer off setting press Timer 1f LCD won t display xx x hour and then it means the timer setting 15 canceled Timer range 0 5 24hr Every press of will make the set time increased or decreased by 0 5hr If either of them is pressed continuously the set time will increase decrease by 0 5hr every 0 5s 6 Swing Setting Swing On Press Function under on state of the unit to activate the swing function In this case it will blink After that press Enter cancel to make a confirmation Swing Off When the Swing function is on press Function to enter the Swing setting interface with blinking After that press Enter cancel to cancel this function Notes a Sleep Save Turbo Blow or Qu
167. run Commissioning of complete unit As bulit drawing Delivery of operating instructions 67 INSTALLATION Super Free Match Service Manual 3 OUTDOOR UNIT INSTALLATION 3 1 Precautions for R410A Itis very strict that the refrigerant pipes should be clean and dry The R410A is a mixed refrigerant when add the refrigerant to the unit it must keep the refrigerant in its liquid state If the refrigerant 1s in gas state the composition has been changed and the capability of the unit will decrease When the refrigerant is leak out please do not touch the leakage Otherwise it will result in frostbite It does not support to let a lot of refrigerant go into the ambient atmosphere because it will strengthen the green house effect Otherwise it will produce toxic gas when the refrigerant contacts with the fire 3 2 Precaution for Installation The unit is so heavy that it is more than 110kg so more than two persons will be needed to remove the unit The package cannot bear it so do not grasping it When remove the units please place the hands on the corner and take care not to hurt the hands by the fins Itis very likely to dispose the waste to the garbage bin after the installation 3 3 Names of Main Parts Inlet air M IT
168. s Open the cover plate of the 1 Pull out the a electric box and then pull electric wire of the out the electric wire inside the box motor Remove the filter 2 Remove the ee lt screen cover plate for E i Unscrew the fixed return air screws of the return air Undo the buckle of the 3 Remove the rear ic zl rear and front volutes and volute zi THp then remove the rear volute away Unscrew the fixed 4 Remove the front screws of the front volute volute and then remove it away MAINTENANCE 7 Super Free Match Service Manual 5 Loosen the fan blade and fan Unscrew the fixed screws of the fan blades and then undo the buckle of the motor motor a Separate the motor away from the motor support Remove the fan blade Take the motor out 6 Remove the n MU NOME motor away ci 4 i from the return air 1 CT n i frame Note the motor support shall be removed in advance and then changed to the unit Assemble the fan as the 7 Replace with a reverse disassembly order new motor and then take a power on test 7 165 MAINTENANCE Super Free Match Service Manual 6 2 3 One way cassette type Assembly and Disassembly of the Water Pump Remark Prior to the assembly of the drainag
169. s a The rated cooling capacity data is measured under the following work condition Indoor Temperature is 27 C DB 19 C WB Outdoor Temperature is 35 C DB The rated heating capacity data is measured under the following work condition Indoor Temperature is 20 C DB Outdoor Temperature is 7 6 CWB b The data will change with the change of products Refer to those parameters listed on nameplate Noise was tested in semi silenced room so actual noise value will be a little higher for change of ambient Super Free Match Service Manual 5 Working Temperature Range orts Dry bulb temp Wet bulb temp Dry bulb temp Wet bulb temp Max cooling Min cooling Rated Heating 1 21 i 20 Max heating x 2 1 Super Free Match E Service Manual 6 PIPING DIAGRAM Schematic Diagram of Super Free Match Series Inverter Heat Pump Multi System The units start to work once the power is switched on During the cooling operation the low temperature low pressure refrigerant gas from the heat exchanger of each indoor unit gets together and then is taken into the compressor to be compressed into high temperature high pressure gas which will soon go to the heat exchanger of the outdoor unit to exchange heat with the outdoor air and then is turned into refrigerant liquid After passing through the BU module the temperature and pressure of the refrigerant liquid will further decrea
170. s So the wall mounted and console types are beyond the scope of the smart zone controller Super Free Match Service Manual 4 2 Communication Network 16 Port 1 VRF Pot 2 Port 3 WRF Port 4 Duct Type Smart Zone Controller Wired Wired Wired Controller Controller Controller a Duct Type Duct Type Duct Type Note The smart zone controller can connect with maximum up to 3 outdoor units and 16 indoor units However the total of the indoor units of all four ports cannot exceed 16 4 3 LCD 4 3 1 Outline of the LCD WE WED THU FRI ROOM SET INNER UNIT wp wm CHILD LOCK CON ace s st 0 l N Mg SHIELD MODE E N e a Cc ON OFF 4 5 6 7 8 SUN MON TUE WED THU FRI SAT 9 IENENE CENTER E 6 8 10 12 14 16 18 20 2 24 2 4 6 E 10 12 18 16 1820 2 2 ao RRR 4 3 2 Introduction to Symbols on the LCD Straight Matter Super Free Match Service Manual m z N SG He TUE V ROOM 5 INNER UNIT ALI LOCK 5 LL nie set f SHIELD MODE 9 10 9 8 T 5 4 It displays the current time hour and minute in 24 hour time system and also 3 System clock the week
171. s 3 the indoor unit runs at high speed When the ambient temperature is higher than the set temperature plus 1 C but lower than the set temperature plus 3 the indoor unit fan runs at the medium speed When the ambient temperature is or lower than the set temperature plus 1 the fan runs at the low speed f Once the fan starts at a certain speed it will keep running at this speed for no less than 30 seconds prior to any changeover stated above 3 AUTO Press Button The whole unit will run under the AUTO mode by pressing this button when the unit 15 off In this condition the fan of the indoor unit will run at the auto speed with the swing function activated When the unit is on it will be turned off by pressing this button This button 15 unavailable to the floor ceiling unit 4 Sleep Under this mode the proper sleep curve will be adopted in accordance with different set temperatures Under the COOL mode or the DRY mode the temperature will go up by after one hour and by another 1 after another hour after that the temperature will be kept Under the HEAT mode the temperature will go down by 1 C after one hour and by another 1 C after another hour after that the temperature will be kept on 5 Timer a Timer On When the unit is powered on but in the idle condition it 1s available to set when to start the unit Then when the unit starts it will run as the previously set mod The set range of
172. s FXB3A K escription 6 _____ Equipment Plate 1 1 insulation sleeve pipe 75094100003 1 75094100003 1 9 Differences eatheterassembly 04224100165 1 04241006 71 2 MAINTENANCE Super Free Match Service Manual 12208100057 m seme 2200055 120055 25 Retaining Plate Water Level Switch 1 _o1s4ai00019P 1 7 Retaining Plate Water Level Swich orsaaioooisp 1 oisanoooise 1 1 1 1 MAINTENANCE mo 5 GREE NM C OMM Add West Jinji Rd Qianshan Zhuhai 519070 Guangdong China Tel 486 756 8522218 Fax 86 756 8669426 Email gree gree com cn http www gree com For continuous improvement in the products Gree reserves the right to modify the product specification and appearancein this manual without JFO0O0301896 notice and without incurring any obligations
173. s with COOL PLASMA GENERATOR Change GWH 07 KF K3DNAG6E T GWH 09 KF K3DNAGE T GWH 12 KF K3DNAGE T GWH 18 KG K3DNA6E I TUBE ROOM TEM SENSOR TEM SENSOR M 5000110 TUBE ROOM CAP za JUMP DISPLAY optional MAINTENANCE Super Free Match a Sevice Manual Viola GWH 07 RA K3DNA3E I GWH 09 RA K3DNA3E I GWH 12 RB K3DNA3E I GWH 18 RC K3DNA3E I GWH 24 RC K3DNAIA I fe 5 TUBE 00 MOTOR TEMP SENSOR THMP SENSOR 1 T ROOM CAP n a c JUMP AC L o 00 3 e TEN ISPL DISPO SWING UD AYEGN E zj EE Y IFALTH L HEALTH N m
174. se and then go the main valve After that it will be divided and go to the heat exchanger of each indoor unit to exchange heat with the air which needs to be conditioned Consequently the refrigerant liquid become low temperature low 7 Super Free Match Service Manual pressure refrigerant gas again Such a refrigeration cycle goes round and round to achieve the desired refrigeration purpose During the heating operation the four way valve is involved to make the refrigeration cycle run reversely The refrigerant radiates heat in the heat exchanger of the indoor unit so do the electric heating devices and absorb heat in the heat exchanger of the outdoor unit for a heat pump heating cycle so as to achieve the desired heating purpose Super Free Match E Service Manual CONTROL m Super Free Match Service Manual Control 1 OPERATION FLOWCHART Connecting To Power Supply Initialization Of Electronic Expansion Valve Start Indicating Light Is ON Testing Board Show The Error Code Yes No Air Supply Blower Stop Expansion Valve Stop Guide Louver Stop anii Cooling Heating Cooling Heating Cooling Heating Air Supply Operation Operation Operation Stop Super Free Match Service Manual 1 1 Cooling Dry Operation Cooling Operation Is there Guide ouver Yes Guide Louvers Swing Fan Motor Operation Is the process
175. sis Reassemble the electrical box cover Recover the surface panel The temperature of refrigerant circuit will be high please keep the interconnection cable away from the copper tube 09 INSTALLATION Super Free Match Service Manual 8 INSTALLATION OF DRAINAGE PIPELINE 8 1 Material Quality Requirements for Condensate Pipe Generally the condensate pipe shall be water supply U PVC pipe adhered by using special glue The other materials available include PP R pipe PP C pipe and hot dipped galvanized steel pipe It 15 not allowed to use aluminum plastic composite pipe 8 2 Key Points for Condensate Pipe Installation 1 Work Order Installation of Sheathing of thermal insulation Connection of Thermal insulation ma DE pipe on condensate pipe drainage pipe of drainage pipe 2 Determine the direction and elevation of condensate pipe before installation To ensure the gradient smooth and straight avoid intersecting with other pipelines The height of the clamp fixing the pipe hanger frame shall be adjustable and fixed from the outer of thermal insulation 3 The gradient of condensate pipe shall be over 1 and the gradient of main pipe shall not be less than 0 3 while there shall be no overhanging slope u 1em 1m Over 1 100 4 When connecting the 3 way section of condensate pipe the 2 way straight section on 3 way pipe shall b
176. speed can be circularly selected 746 gt Low speed Medium speed High speed Note Under AUTO Speed indoor unit fan motor will adjust the fan speed high medium low speed according to ambient temperature Fan speed under dry mode is low speed 5 SWING UP and DOWN di Press this button gt to set up amp down swing angle which circularly changes below Super Free Match Service Manual ct zb 1 71 m no display horizontal louvers stops at current position When selecting remote controller it s auto swing Horizontal louver of air conditioner will swing up amp down automatically at the maximum angle When selecting 1 1 remote controller it s the fixed position swing Horizontal louver of air conditioner will stop at that position as shown by the icon to swing 6 SWING LEFT and RIGHT Press this button to set left amp right swing angle cycling as below m gt __ __ E 7 no display 4 m em horizontal louvers stops swing angle is dis at current position played dynamically When selecting with remote controller it s auto swing Horizontal louver of air conditioner will swing left amp right automatically at the maximum angle 3 1 Whenselecting with remote controller it s
177. ss Indoor unit E gas tube temperature b7 indoor Flash 9 times b7 unit address Indoor unit E liquid tube 5 indoor Flash 10 times b5 temperature sensor error unit address 3 FLOW CHART OF TROUBLESHOOTING MAINTENANCE Ea Super Free Match Service Manual Service personnel shall collect the malfunction information as much as possible and research them thoroughly list these electrical parts which may cause malfunction service personnel shall be able to determine the specific reason and solve the faulted parts Observe the status of the complete device and do not observe the partial It is advised to start from the simple operation during analyzing judging and confirming malfunction reason then conduct the complicated operations such removal of device part replacement and refrigerant filling Find the malfunction reason carefully as unit may occur several malfunction at the same time and one malfunction may develop into several malfunction so entire system analysis shall be established to make the judged result exact and credible 3 1 Malfunction display High Pressure Protection High pressure protection No Replace the outdoor unit mainboard Check the high pressure sensor 15 it normal Check the pressure with a manometer is it really high Replace the high pressure sensor Yes No Replace the pressure switch
178. t temperature When the indoor unit firstly power on it will display the setting temperature if the temperature s displaying status is changed from other status to displays the ambient temperature 55 later within 5s it receives other remote control signal that will return to display the setting temperature If the users haven t set up the temperature displaying status that will display the setting temperature 11 QUIET Press this button the Quiet status is under the Auto Quiet mode display GD signal and Quiet mode display Gp signal and Quiet OFF there is no signal of G aisplayed after powered on the Quiet OFF is defaulted Note the Quiet function cannot be set up in Fan and Dry mode Under the Quiet mode Display p Under the Quiet mode Display p signal the fan speed 15 not available 12 CLOCK Press CLOCK button blinking Within 5 seconds pressing button adjusts the present time Holding down either button above 2 seconds increases or decreases the time by 1 minute every 0 5 second and then by 10 minutes every 0 5 second During blinking after setting press CLOCK button again to confirm the setting and then will be constantly displayed Super Free Match Service Manual 13 T ON T OFF Press T ON button to initiate the auto ON timer To cancel the auto timer program simply press this button again After press of this button disappears ON b
179. tch 7 1 Outdoor unit GWHD 48S NM3CO GWHD 56S NM3CO le 13 C Er 0p 3L 26 cb 27 28 7 lt Z 4 p lt Super Free Match Service Manual Part list GWHD 48S NM3CO GWHD 56S NM3CO 0 01240030 0 3 ReaetorBox o 0 9 Motor Suppor Sub assy 1 1 24 Liquid Sop Vane 0753000008 1 07330000002 1 1 ome 1 26 Protect switch 1 4602000002 1 7 ChassSdbesy 1 0119410000301 1 2 xum 1 1 3 1 30 1 1 Pai Magnet Coit i 300040029 3 1_ mem 2 mem 2 Description gt Gas Bypass Sub assy 1 1 wf meco 11 7 08 MAINTENANCE Super Free Match Service Manual Lar Pressure regulating valve 07534100000 711 973341009 1 Cas Electromagnetic Valve 4300054 1 4309054 1 Magnet Coit 1 Bowons 1 Expansion Valve 1 1 Expansion Valve Coit 4304413005 1 4029 1_ 2 Electronic Expansion Valve 43042800005 1 43042800005 Electronic Expansion V
180. ted to avoid mildew In the Cooling or Dry mode press Function till the unit enters the Blow setting interface and then press Enter Cancel to active this function When the Blow function is activated press Function to the Blow setting interface and then press Enter Cancel to cancel this function Notes a When the Blow function 15 activated if turning off the unit by pressing On Off or by the remote controller the indoor fan will run at the low fan speed for 10 min with BLOW displayed on the LCD While if the Blow function 15 deactivated the indoor fan will be turned off directly b Blow function is unavailable in the Fan or Heating mode 11 Other Functions Lock Upon startup of the unit without malfunction or under the Off state of the unit press and atthe same time for 5s till the wired controller enters the Lock function In this case LCD displays After that repress these two buttons at the same time for 5s to quit this function Under the Lock state any other button press won t get any response Memory Memory switchover Under the state of the unit press Mode and A the same time for 5s to switch memory states between memory on and memory off When this function 15 activated Memory will be displayed If this function is not set the unit will be under the state after power failure and then power recovery Memory recovery If this function has been set for the wired controller the w
181. the timer is 0 5 24 hours with a interval of 0 5 hour b Timer Off When the unit is on it 15 available to set when to stop the unit The set range of timer 1s 0 5 24 hours with a interval of 0 5 hour 6 Memory a Memorizing Objects modes AUTO COOL DRY FAN HEAT swing set temperature set fan speed etc b When the indoor unit works without the wired controller it will resume the working condition as the power failure occurs after it is powered on again When the indoor unit is with the wired controller it 15 available to set the memory function by pressing the corresponding buttons of the wired controller Super Free Match Service Manual c When the indoor unit works without the wired controller if the timer is not set for the last remote control instruction the system will memorize this last instruction and works following it if the timer is set it will be canceled as the power failure occurs and will have to be reset d When the indoor unit works with the wired controller 1t will work as the message sent by the wired controller after it is powered on again 7 Selection of the Indoor Temperature Sensor a For the duct type indoor unit Under the COOL HEAT DRY or FAN mode the return air temperature sensor is adopted while under the HEAT mode it 1s the receiver temperature sensor For the cassette type floor ceiling type indoor unit Under all modes the return air temperature sensor is adopted b When
182. the unit The drainage of the drain pipe is easy No obstacle 15 in the inlet outlet and the air circulation is in good condition Ensure the installation space is left for the access to maintenance It should be far away from where there is heat source leakage of inflammable explosive substances smog It is the ceiling type unit concealed 1 the ceiling 9 The power cords and connection lines of the indoor and outdoor units must be at least 1m away from the TV set or radio to avoid the image interference and noise even if 1m is kept the noise may be produced due to the strong electric wave INSTALLATION Super Free Match Service Manual 4 2 4 Outline Dimension Drawings of the Indoor Unit Note the unit in the followings figures 15 mm unless otherwise specified G lectric Box Liquid Pipe Gas Pipe Backward Return Air Drain Pipe Downward Return Air F E UT K3DNAIA I 528 620 700 615 782 200 635 GFH 12 EA K3DNAIA I_ mca sr pw sc GFH 24 EA K3DNAIA I 4 2 5 Dimension Requirements on the Installation Space of the Indoor Unit Nut with washer 17 INSTALLATION Super Free Match Service Manual 4 2 6 Installation of the Indoor Unit Requirements on the Installation Location Ensure the hanger is strong enough to withstand t
183. tion starts The hi humidity air indoor is cooled quickly The unit clatters as soon as it It is the sound generated during the initialization of starts running the electronic expansion valve The unit swishes during the It is the sound when the refrigerant gas runs inside cooling operation the unit The unit swishes when it 1s The unit generates noise It 15 the sound when the refrigerant gas stops running started or stopped The unit swishes when it is in It 15 the sound when the draining system 15 operating and after the running The unit squeaks when it 1s in It is the sound of frication generated by the skin plate and after the running etc which swells due to the temperature change When the unit restarts after it is The unit blows out dust The dust inside the unit is blown out again not used for a long time The unit emits odors When the unit is running The odors absorbed in are blown out 2 3 Error description Outdoor unit If some error occurs when the unit 15 running the error code will be displayed on the wired controller the testing board 88 of the outdoor unit Check for more details about the meaning of each error EN Indoor unit Testing board Errors of definition 7 07 PM temperature protection Fish times Sid PC current protecion Hc PEC temperature protection _
184. tton for confirmation the setting temperature 88 will display the corresponding temperature of last setting sleep curve and blink The first entering will display according to the initial curve setting value of original factory 3 At this time 1hour will be automatically increased at the timer postion on the remote control that are 2hours or 3hours 8hours the place of setting temperature 88 will display the corresponding temperature of last setting sleep curve and blink 4 Repeat the above step 2 3 operation until 8hours temperature setting finished sleep curve setting finished at this time the remote control will resume the original timer display temperature display will resume to original setting temperature Sleep3 the sleep curve setting under Sleep mode by DIY could be inquired The user could accord to sleep curve setting method to inquire the presetting sleep curve enter into user individuation sleep setting status but do not change the temperature press Turbo button directly for confirmation Note In the above presetting or enquiry procedure if continuously within 10s there is no button pressed the sleep curve setting within 10s there is no button pressed the sleep curve setting status will be automatically quit and resume to display the original displaying In the presetting or enquiry procedure press ON OFF button Mode button Timer button or Sleep button the sleep curve setting
185. uired installation space 15 in the following figure The unit of the values 15 mm TE INSTALLATION Super Free Match Service Manual 3 8 Installation of the Outdoor Unit 1 Check the installation location and ensure it is strength and level so that the unit will not cause any operating vibration or noise after installation 2 In accordance with the foundation drawing in the following figure please drill 4 holes in the installation location 57251 375 5 380 5 A The outlet side B Bottom view mm C Drain hole 3 Fix the unit securely with the foundation bolts You can get the M10 M8 foundation bolts nuts and washers from the market 77 2 4 Rubber or spring shock absorbers should be used during the installation of the outdoor unit to meet the noise and vibration requirements 5 Screw the foundation bolts into the ground and it is better that their length is less than 20mm from the foundation face INSTALLATION Super Free Match Service Manual 4 INDOOR UNIT INSTALLATION 4 1 Installation of Wall Mounted Type 4 1 1 Important Notices The installation of air conditioner unit must in accordance with national and local safety codes Installation quality will directly affect the normal use of air conditioner unit The user is prohibited from installation by himself Please contact the dealer after buying this machine Professional installation workers will provide inst
186. ulate the indoor drain pipe with 10mm or more of insulation material to prevent condensation 6 Remove the air filters and pour some water into the drain pan to check the water flows smoothly Must be no trap Do not touch water _ a 50mm T Drain hose Vinyl chloride drain pipe Reducer 7 Insert the supplied C drain hose into the socket of the drain pan 8 Fully insert the drain hose until it adheres to a seat of the socket Drain pan Seal 97 INSTALLATION Super Free Match Service Manual 5 BU MODULE INSTALLATION 5 1 Precaution for Installation The installation of the air conditioner must be in accordance with the national and local laws and regulations The quality of the installation will affect the capability of air conditioner directly The installation should be left to the appointed service center Please contact your dealer after purchasing this machine Professional installation workers will provide installation and test services according to the installation manual The air conditioner should not install in this place where the small animals exist because they may cause malfunctions smoke or fire Please keep the area around the unit clean 5 2 Names of Main Parts a FXB3A K 4 2 css K Gas piping indoor piping of Gas piping
187. uld be follow the following rules Outdoor unit shall be installed close to the indoor unit hence to minimize the length and bends of connection pipes The height gap of outdoor unit and indoor units should be as small as possible The brazing operation must be strictly accordance with the process requirements During the installation do not damage the pipeline 6 8 2 The process of flaring QD 2 Using the tube cutter to cut the connecting pipe in the appropriate place and remove the burrs Install the nut before the flaring operation Check the flared portion whether there is fractured or not 6 8 3 Precaution for elbow operation The elbow operation could be done by hands Be careful and do not damage the pipe mec a y ie E ia 2 gt n EM t Fi fa a 3 5 1 p 4 if _ te m a _ J a 7 a a NS y a X Fight E Wrong The bending diameter of the pipeline must be greater than 200mm The connection pipe cannot often be bent or straightened Otherwise it will harden and crack If the thermal insulation of the refrigerant pipe is not removed please do not bend the pipe Otherwise it maybe leads the pipe to crack It is better to make an incision with a knife in the thermal insulation and removes it After elbow operation is finished recover the thermal insulation with bind
188. ure sensor ect Outdoor temperature B Suction temperature sensoreror sims d Condenser temperature sensor enor 7 sub cool temperature sensoreror Low pressure sensor enor OO 4 Fan motor protection for outdoor anit m Driving boardiscomected board is connected Flash times Computer is connected indoor unit is connected indoor units conned ___ ________________ indoor unit is connected did ames indoor unit is conned indoor unit Sis comme indoor unit 6is connected indoor indoor unit is conned Indoor Indoor temperature sensor error __ sensor error Indoor evaporator midway temperature Temperature sensor error for liquid pipe Temperature sensor error for gas pipe of MAINTENANCE 7 Super Free Match Service Manual LL EE o m ewkc Communi indoorunit n E error Lmaew g Communication erro
189. utton again to repeat the operation above 9 SLEEP 1 2 3 Press this button can select Sleep 1 Sleep 2 E Sleep 3 and cancel the Sleep circulate between these after electrified Sleep Cancel 15 defaulted Sleep 1 is Sleep mode 1 in Cool or dry mode sleep status after run for one hour the main unit setting temperature will increase 1 after 2 hours the setting temperature will increase 2 but the maximal setting temperature is 30 C then the unit will run at this setting temperature all along In Heat mode sleep status after run for one hour the setting temperature will decrease 1 after 2 hours the setting temperature will decrease 2 but the minimal setting temperature is 16 then the unit will run at this setting temperature Sleep 2 is sleep mode 2 that is air conditioner will run according to presetting a group of sleep temperature curve Super Free Match Service Manual Sleep 3 the sleep curve setting under Sleep mode by DIY 1 Under Sleep 3 mode press Turbo button for a long time remote control enters into user individuation sleep setting status at this time the time of remote control will display 1hour the setting temperature 88 will display the corresponding temperature of last setting sleep curve and blink The first entering will display according to the initial curve setting value of original factory 2 Adjust and button could change the corres
190. vaporator Assy 1 is CodPmmiGeenor 19 1 _ 3 Wall Mounting Frame x Motor Press ite 3 m 1 m meeigppesam 1 x 3 1 3 m 2 x Cette Box Assy 1 x me 4m 3 eat Box Cover 1 39 Y _ 3 3m _ x emiiBad _ 1 EemeBwCoed 1 3s Remote Conroe 1 _ 3s Temperature Sensor 1 Temperature Sensor _________ 1 3 Connecting Cable 0o MAINTENANCE Super Free Match Service Manual Cozy GWH 07 MA K3DNAS3E I GWH 09 MA K3DNA3E I GWH 12 MB K3DNA3E I Part list GWH 07 MA K3DNA3E I_ for CB171N08600 GWH 09 MA K3DNAS3E I for CB171N08501 GWH 12 MB K3DNA3E I for CB171N08701 GWH 07 MA K3DNA3E I GWH 12 MB K3DNA3E I NO Description GWH 09 MA K3DNA3E I Front Panel Assy 20012241 20012548 Filter Sub Assy 11122081 1112220403 2 N 4 Cover 2096 3 2408061 1 1 _ 6 ___
191. w speed Ifthe ambient temperature minus 3 C is equal or lower than the set temperature the fan will run at the medium speed Ifthe ambient temperature minus 3 is lower than set temperature minus 3 C the fan will run at the high speed b Under the COOL mode Ifthe ambient temperature is equal to or lower than the set temperature the fan will run at the low speed Ifthe ambient temperature is between the set temperature and set temperature minus 3 C the fan will run at the medium speed Ifthe ambient temperature is higher than the set temperature plus 3 C the fan will run at the high speed c Under the FAN mode The fan will run at the medium speed constantly Once the fan starts its speed cannot be changed unit it has run for at least 30 seconds at the currently set Super Free Match Service Manual speed d Under the HEAT Mode Ambient temperature herein is the temperature without temperature compensation When the ambient temperature is or lower than set temperature the indoor unit runs at the high speed When the ambient temperature is higher than set temperature but lower than the set temperature plus 2 the indoor unit fan runs at the medium speed When the ambient temperature is or lower than set temperature plus 2 C the fan runs at the low speed e Under the COOL and FAN Modes When the ambient temperature is or higher than the set temperature plu
192. wer 1 1 metuo 017 RearCase assy 2020229501 1 2220229501 1 2239094 1 Pipe plug outlet 76712020 1 7672900 1 7672012 2 Asile Bush subassy 10542024 1 105004 1 10542047 13_ Damping washer subassy 76512011 1 31 7 4 Connecting 400204056 0 40020456 0 4002052317 i i Ambient Temperature 17 390000453 1 390000453 1 390000453 1 Evaporator Support 1 1 1 9 Evaporator Assy 01002957 1 00095 1 lors 1 20 Wali Mounting Frame 0125201801 1 0125201801 1 21 Cross Flow Fan 10352423 1 10352423 10352036 22 Moor Prespas 1 1 FanMowor 1 irr 1 50546 merae 26nzns 1 1 35 Drainage Pipe Sub asy 0523208101 1 05232040 1 0523001407 1 P26 Step Motor 1 1 15012086 1 Crank 7802008 7800005 1 i097 1 La ___ 20550 1 2002s 1 1_ gt 20112086 1 1 20112103 1 indicator Light Cover 2240094 1 1 71 Par Terminal Board 4201239 1 1 1_ 32 indicator shield cover 22242083 1 22042083 1 22508 ___ 1 soise 1 1 34 Capacitor canst 3301
193. y downward to the outdoor side 2 Insert the piping hole sleeve into the hole to prevent the connection piping and wiring from being damaged when passing through the hole Indoor Outdoor Wall pipe j 55 70 4 1 7 Installation of drain hose 1 Connect the drain hose to the outlet pipe of the indoor unit Bind the joint with rubber belt indoor unit indoor unit drain hose rubber belt INSTALLATION Super Free Match Service Manual 2 Put the drain hose into insulating tube outlet pipe of drain hose indoor unit rubber belt insulating tube 3 Wrap the insulating tube with wide rubber belt to prevent the shift of insulating tube Slant the drain hose downward slightly for smooth drainage of condensate rubber belt outlet pipe of indoor unit 2 Ad BN connected insulating tube Note The insulating tube should be connected reliably with the sleeve outside the outlet pipe The drain hose should be slanted downward slightly without distortion bulge or fluctuation Do not put the outlet in the water distortion gt lt gt lt Flooded 18 INSTALLATION Super Free Match Service Manual 4 2 Installation of Duct Type 4 2 1 Installation Location and Matters Needing Attention The installation of air conditioner unit must be in accordance with national and local safety codes Installation qu
194. y professional personnel according with this instruction Please contact the local Gree special nominated repair department before installation Any malfunction caused by the unit that 15 installed by the department that is not special nominated by Gree would not deal with on time by the inconvenience of the business contact 4 3 3 950 Decorated surface boards 890 Ceiling opening Outline Dimension Drawings of the Indoor Unit 650 570 400 840 Indoor unit 780 Gaps between hoisting screw rods 680 Gaps between hoisting screw rods 840 Indoor unit 890 Ceiling opening 950 Decorated surface boards Super Free Match Service Manual 570 604 650 Refrigerant pipe Hoisting screw X4 GKH 12 BA K3DNAIA I 18 GKH 24 BA K3DNAIA I 85 INSTALLATION Super Free Match Service Manual 4 3 4 Installation and Servicing Space Wall surtace 5 p surface surtace 1500 W n en ce gt i 1800 unit mnm 5 S The drilling of holes in the ceiling must be done by the professional personnel Installation stands for main body of the unit Ceiling Above 20 4 3 5 Installation of the Indoor Unit The primary step for install the indoor unit When attach the hoisting stand on hoisting screw do use nut and gasket individually at the upper and