1. SERIAL NUMBER LABEL AUTO ADAPTER 4 RemRest REMREST CLEANING To clean the RemRest device turn OFF the unit and unplug it from the power source Using a damp cloth wipe the unit clean making sure no liquids enter the device itself Allow the unit to completely dry prior to using REMREST INLET FILTER The RemRest filter is located on the back of the device and is reusable To make sure your device continues to provide optimum performance check your filter weekly and clean the filter once per month or sooner if dirty To clean the filter remove the filter from the unit and wash it in warm water until the water runs clear Allow the filter to completely air dry Once the filter is dry return it to its housing SYSTEM SERVICE Do not attempt to open or remove the outer covers of the CPAP as there are no user serviceable internal components Do not attempt to repair this unit on your own as this may cause further damage and will void the warranty If service is required have your care provider return this device to an authorized evo service center RemRest 5 WARNING Make sure to unplug the device from the wall outlet or DC power source before cleaning as failure to do so may cause electric shock CAUTION Never place or submerge this unit under water or place near a water source of any kind Do not allow lig uids to enter in
2. Call Dealer for service Clean or replace the filter Remove obstruction or reposition the unit so the inlet is not blocked Connect flexible hose to device Verify the green light is on if not push the on off button Call Dealer for service Call Dealer for service Call Dealer for service Call Dealer for service Call Dealer for service Call Dealer for service The internal data code light must be read by the technician Consult your dealer manual evo warrants the RemRest to be free from defective workmanship and materials for a period of 3 years from the date of purchase Check with your care provider for more details This warranty is limited to the care provider Any defective part or assembly will be repaired or replaced at the sole discretion and determination of evo if the unit has not been misused or tampered with during the warranty period Normal maintenance items and disposable components as outlined in this manual are not covered by this warranty Shipping charges if any shall be paid by the purchaser RemRest j NOTE There is no other express warranty Implied warranties including those of merchantability and fitness for a particular purpose are limited to the duration of the express limited warranty and to the extent permitted by law and all implied warranties are excluded This warranty does not cover providing a loaner device compensating for costs incurred for device rental
3. RemRest Tiers 1 3 900 Series Service Manual CAUTION USA Federal law restricts this device to sale by or on the order of a physician P N 22054 Rev A EC Symbols SIZE System Components 4 7 H X 8 6 W X 9 4 D 11 9cm H x 21 8cm W x RemRest Care 23 9cm D WEIGHT Troubleshooting lt 5lb 2 3kg Warrant PRESSURE RANGE 3 5 CMH20 TO 20 CMH20 RAMP TIME 5 TO 50 MINUTES ELECTRICAL REQUIREMENTS 100 240V 50 60 HZ or 12 VDC 40 Watts OPERATING TEMPERATURE RANGE 41 F to 104 F 5 C to 40 C STORAGE AND TRANSPORTATION TEMPERATURE RANGE 4 F to 140 F 20 60 C STORAGE AND TRANSPORTATION HUMIDITY RANGE 1096 TO 9596 RH non condensing SOUND LEVEL 30 dba 10cmH20 1 meter from CPAP 2 RemRest Equipment Classification with respect to protection from electric shock Class 11 Degree of protection from electric shock Type BF Degree of protection against ingress of liquids Ordinary Equipment not suitable for use in the presence of flammable anaesthetic mixture with air or with nitrous oxide Mode of operation Continuous AN Attention consult accompanying documents Type BF eguipment Direct Current NS Alternating Current RemRest 3 LCD DISPLAY TIER 2 amp 3 MODELS KEY PAD DC PLUG DB9 CABLE CONNECTOR TIER 2 amp 3 ONLY AIR OUTLET SIDE BOTTOM INLET FILTER
4. or labor costs incurred in repairing or replacing defective part s ActiveForever com A ActiveForever co LIFE ENHANCING PRODUCTS amp SOLUTIONS sore 1 800 377 8033 Ju EVO Medical Solutions 2636 289th Place Adel IA 50003 515 993 5001 515 993 4172 f 800 759 3038 toll free
5. to this device Doing so may result in device damage CAUTION Do not clean RemRest device with alcohol or alcohol based products NOTE There is no other express warranty Implied warranties including those of merchantability and fitness for a particular purpose are limited to the duration of the express limited warranty and to the extent permitted by law and all implied warranties are excluded This warranty does not cover providing a loaner device compensating for costs incurred for device rental or labor costs incurred in repairing or replacing defective part s Unit will not run No air comes out while the unit is on Keypad buttons do not respond when pressed Unit is excessively noisy Unit pressure won t stabilize Unit won t initiate technician mode Tier 2 amp 3 Only LCD Display does not work or shows garbled or missing segments Tier 2 amp 3 Only Error 1 5 Message Tier 2 amp 3 Only Green starts to blink 3 seconds on 1 second off Unit not plugged into a live outlet Power cord not connected properly Hardware problem Air filter is plugged Air inlet is blocked Flexible hose not connected to device Unit plugged in but device not turned on Hardware problem Unit blower is out of balance or bearing is bad Hardware problem Hardware problem Hardware problem Hardware problem 6 RemRest Plug unit into a live outlet Firmly attach AC or DC cord