1. 1 Remove the battery pack from the hoist and place it in the wall mounted charger 2 Check to ensure that the LED lamp on the front of the charger lights up NOTE Before the lift is used for the first time it must be charged for at least 4 hours For maximum battery life charge batteries regularly We recommend daily charging when the lift is used daily The emergency stop button must be pulled out during charging Handset Raising lowering the lift arm Symbol indicate direction of travel Motion stops as soon as the button is released Widening narrowing the base Markings on the buttons indicate function Motion stops as soon as the buttons are released 6 MANUAL SystemRoMedic Emergency stop To activate emergency stop Depress the red emergency stop button on the control box Resetting Turn the button in the direction of the arrows until the button pops out o Emergency lowering Manual emergency lowering For manual emergency turn the round plastic knob on the actuator clockwise Electrical emergency lowering For electrical emergency use the down button on the control box Trouble shooting If the lift or base width adjustment cannot be activated check the following That the emergency stop button is not pressed in That all cables are properly and securely connected Pull out the contact and plug it in again firmly That batt
2. 2 75 25 26 79 77 22 19 70 66 59 21 28 68 56 23 25 70 53 51 22 47 67 34 67 4 53 2 36 52 4 75 65 54 37 77 62 56 34 79 59 21 67 SystemRoMedic MANUAL 11 Dimensions Eva450EE Column A measurement is in cm and weight is in kg Column B measurement is in inches and weight is in Ibs A B 44 17 34 J 45 17 73 K 58 5 88 23 05 34 67 L 68 5 98 26 99 38 61 M 134 54 N 34 74 9 O 14 5 31 9 Q 27 10 64 S 41 16 1 J 292 8 7 U 45 172 M is turning diameter N is total weight of lift 0 is the weight of the heaviest component P is movement in forward direction R is referencemeasure 70 cm with max legspreading S is minimum distance from wall to slingbar at maximum height legs spread T is minimum distance from wall to slingbar at maximum reach legs spread U is minimum distance from wall to slingbar at minimum height legs spread MANUAL SystemRoMedic SystemRoMedic For 25 years we have applied ourselves wholeheartedly to developing smart and easy to use assistive devices for easy transfers and to making life and work easier for both patients and personnel in the care sector Experience innovation and training are the basis for SystemRoMedic a total solution for every imaginable transfer situation Transfer products for moving patients between locations Positioning products for repositioning in the same location Support products that provide mobility support Lifting pr
3. bolts Check the emergency stop function by depressing the emergency stop and then pressing either the up or down button If nothing happens when the up or down buttons are pressed the emergency stop is functioning properly Grasp the handset press the up button and run the lift arm all the way up Then press the down button and run the lift arm all the way down Test base width adjustment function Press the button for base width adjustment to widen the base fully and then press the other button to narrow the base again Test lift function by lifting a person not a patient using an approved sling At the same time check the emergency lowering function with someone on the lift See section on Emergency lowering If the lift is functioning correctly connect the charger and check to ensure that the charging lamp on the control box lights up NOTE Before the lift is used for the first time it must be charged for at least 4 hours See section on charging batteries Keep the manual where it is accessible to users of the product MANUAL SystemRoMedic Using the product A Important Information e The lift must be assembled according to the assembly instructions provided with the lift e The lift may only be used indoors and on a level floor e Lifting accessories must be properly trial fitted and tested in relation to the patient s needs and functional ability e Do not leave the patient unatte
4. d instruction in the operation of the lift Manual nr 00789En Ver 2 110203 e handicare Table of contents Assembly Final inspection Using the product Important information Safe working load Charging batteries Handset Emergency stop Emergency lowering Trouble shooting Accessories Maintenance Technical information Dimensions Eva450EE 10 11 12 MANUAL SystemRoMedic Assembly Check to ensure that all components are included Mast with boom lift motor carry bar control box and battery pack Base with motor and locking handle Handset and cord Instructions charging cable and power supply cord for charging Place the mast in the base There are three alternatives for adjusting the height of the mast Secure the mast with the locking handle LU Place the battery in the mount in the control box Mount handlebar with two wrenches Connect the cables The cable for the handset in outlet HS the cable for the hoist motor in outlet M1 and the cable for the base motor in outlet M2 Release the emergency stop and perform a final inspection see final inspection SystemRoMedic MANUAL Final inspection Check to ensure that no parts have been left in the packaging Inspect the lift for signs of wear and damage Check all four castor wheels and castor wheel locks Check all connections and fixtures including screws and
5. ery charging is not in progress That the battery is charged If the lift is not working properly contact your dealer If the lift makes unusual noises Try to determine the source of the sound Take the lift out of operation and contact your dealer SystemRoMedic MANUAL if Accessories SystemRoMedic Slings SystemRoMedic offers a wide variety of functional and comfortable high quality lifting slings adapted to meet the different requirements of all kinds of lifting situations and users The Vin lifting slings are available in four different materials and in sizes ranging from XXS to XXL All models are safe and very easy to use Sling bars a Am D SlingBar is SystemRoMedic s aluminium sling bar It s available in three different widths and is qa smD therefore suitable in most lifting situations and for users of all sizes SlingBar S article no 70200001 SlingBar M article no 70200002 SlingBar L article no 70200003 SideBar article no 70200013 SwiftHook for sling bar article no 70200008 StretcherBar article no 70200006 and StretcherSling article no 46502007 for lifting in a supine position Scale SystemRoMedic s scales Charder MHS2500 are used together with stationary or mobile lifts for weighing of users Article no 70100002 Article no 70200003 AmbulationArm AmbulationArm mounted on the mast and provides support during gait training Article no 80100010 Assistive devices for pos
6. itioning SystemRoMedic includes a wide range of functional comfortable high quality assistive devices for positioning that can be adapted for different types of lifting and for patients with different needs Ready for life Sling bar The Ready for life four point slingbar Sling bar RFL X4 is designed to provide more space in the sling for example for obese and or pain sensitive users Article no 70200017 8 MANUAL SystemRoMedic Maintenance The lift must undergo thorough inspection at least once per year Inspection must be performed by authorized personnel and in accordance with Handicare s service manual Repairs and maintenance may only be done by authorized personnel using original spare parts X Spent batteries are to be left at the nearest recycling station Spent batteries can also be returned to Handicare or a Handicare dealer for recycling Cleaning disinfection Clean the lift with warm water or rubbing alcohol and ensure that the castor wheels are free of dirt and hair Do not use cleaning agents containing phenol or chlorine as this may damage the material Storage If the lift is not to be used for some time or e g during transport we recommend that the emergency stop button be pressed in Store the lift at a temperature above freezing point and not exceeding normal relative humidity about 60 Service agreements Handicare offers the possibility of service agreements for maintenance and regular te
7. nded during a transfer situation e Under no circumstances may max load be exceeded See section on Safe working load e Never move the lift by pulling on the actuator Bn e The lift must not come in direct contact with water e The lift must not be charged in a wet room e To ensure optimal function the lift must be inspected regularly See section on Maintenance e Warranty applies only if repairs or alterations are done by an authorized technician Safe working load Different products on the same lift system lift unit slingbar sling scales and other lifting accessories may have different allowable safe working loads The lowest allowable safe working load always determines the safe working load of the assembled system Always check the safe working loads for the lift and accessories before use Contact your dealer if you have any questions SystemRoMedic MANUAL Charging batteries A tone when using the lift indicating that the batteries need recharging Charge the lift after use to ensure that the battery is always fully charged Lock the castor wheels when charging the battery 1 Connect the charging cable to a power outlet 2 Check to ensure that the lamps on the control box light up The green LED lamp indicates that the charger is receiving power and the yellow LED lamp indicates that the battery is charging 3 Charging stops automatically when the battery is fully charged Wall mounted charger
8. oducts adapted for lifting The philosophy behind SystemRoMedic is to prevent occupational injuries while improving the patient s sense of inde pendence and dignity Through a combination of training and a complete range of transfer assistive devices SystemRoMedic offers the means to improving both the work environment and the quality of care while enabling significant cost savings Our mission to help people has always been and will continue to be the driving force of innovation We love easy transfers Contact your local distributor if you have any questions about the product and its use See www handicare com for a complete list of distributors Always make sure that you have the right version of the manual The most recent editions of manuals are available for downloading from our website www handicare com H handicare Handicare AB Veddestav 15 Box 640 SE 175 27 J rf lla SWEDEN Tel 46 0 8 557 62 200 Fax 46 0 8 557 62 299 E mail info handicare se Internet www handicare com
9. qa Eva450 E E Manual English SystemRoMedic Boom Mast Handlebar Battery pack Emergency stop Control box Motor for base width adjustment Rear castors with brakes SlingBar with safety latch 10 Front castors SRN Vf oS YS 11 Emergency lowering 12 Motor actuator for boom 13 Mast height adjustment Max load 205 kg 450Ibs Mobile lift Eva450EE has been developed to meet most lifting needs in combination with the right accessories It is a lift that can lift patients in a seated or supine position The Eva450EE is made largely of aluminium which makes it relatively light considering the weight it can lift Handicare s SystemRoMedic product series includes a range of lifts slings and other accessories SystemRoMedic adopts a holistic approach to patient transfers and is organized in four categories transfer positioning Support and lifting e Functional inspection Visual inspection Inspect lift functions regularly Check to ensure that material is free from damage Before use Ensure that the product is correctly assembled Check slingbar connection and safety latch function Check lift and base width movement Check to ensure that the actuator is correctly installed pH Always read the manual Always read the manuals for all assistive devices used during a transfer Keep the manual where it is accessible to users of the product The lift may only be used by persons who have receive
10. sting of your mobile lift Contact your local Handicare representative SystemRoMedic MANUAL Technical information Lifting speed Batteries Charger Motor mast Motor base Sound level Material Emergency lowering Castors Weight IP class Expected lifetime Operating forces buttons on handset 34 mm s without load Two 12V 2 9 Ah valve regulated sealed lead accumulator gel type batteries Max 400mA DC 24 V 10 A IP X4 Operationtime 10 at maximum continous operation of 2 minutes maximum 5 5 cycles per minute Push 10 OOON 24 V 3 A IP X4 Operationtime 10 at maximum continous operation of 2 minutes maximum 5 5 cycles per minute Push 3000N With load upwards 74 7 dB A downwards 52 6 dB A Aluminum Mechanical and electrical Front 4 100 mm back 4 100mm 75 lbs 34 kg IP X4 10 years 4N The lift complies with the requirements of Council Directive 93 42 EEC of 14 June 1993 concerning medical devices The device is intended for indoor use Type B according to the degree of protection against electric shock MANUAL SystemRoMedic Dimensions Eva450EE A A1 58 186 A2 63 191 A3 68 196 Bi 50 169 B2 54 174 B3 59 179 C1 130 C2 121 D 8 E 11 5 F 6 G1 133 192 G2 138 197 G3 143 202 H 55 Column A measurement is in cm and weight is in kg Column B measurement is in inches and weight is in Ibs B 22 85 73 28 24 8