1. 000o BOON EDAM Security Access SPEEDLANE 900 Operating manual Your Security Our Solution Operating Manual TABLE OF CONTENTS 1T PREFACE EE 2 2 INTRODUCTION BEE 3 2 1 CONCEPT AND DESIGN ME 3 S VARIATIONS EE 5 3 1 STANDARD UNIT wecwsade ses ged Eege de TE N EA A E a E HESE AA E aA 5 S z HEIGHTENED UNE sue Gees Ea E ESET EE SEG 5 3 3 WIDENED UNIT wiisSsiteeccanacce wea veiageg ee AER AA ENEE EE ides tease EE lege d AR EE 6 3 4 EENGTHENEDIUNIT eebe Eed e eebe EE EC Ehe 6 3 5 MULTIPLE SPEEDEANES OPTIONAL ripsiin saaara sie e aE AE E eit Sege dE Ee eEN NEE D 7 E len ageet e H 3 7 DISPLAY ee 8 4 OPERATING CONCEPT issis a ae SNE EE ee aaa 9 4 1 INTRODUCTION ugereegt Eeer Deg ae EE 9 4 2 STANDARD OPERATION sis scciuvecsctvwsscaevacteanadensensd seas EE NES d oeeReduwestnabets SEN SNE ER E gh 9 4 2 1 Normally closed mode default settingl eset eect ee eee ee teens eae eeeeaeeeenees 9 4 2 2 Normally open mode optional for lengthened Speedlane eceeee ee eee 10 4 3 DIRECTION TYPES EE 10 4 4 CARD READER CONTROL cer ssaccasangrosanseseaaaveneak aoe ence TOT E EE EAE HSE neces Seege 10 4 5 SECURITY ee eebe mas na ese eee eh aN oe Naina eae 11 4 5 1 Low security mode default setting eect ee et etre eee e neta eee eaeee ea eeeneas 12 4 5 2 Medium security Mode si secciceceei Se REENEN K Ped SE ENEE ee ANE 12 4 553 FIG SCCUFIEY le Te EE 12 Abed rette Moderar citer ege ege deeg EEN dege
2. The passage length of this Speedlane is 2580 mm Optional for the lengthened Speedilane the card reader system can be built into the extended column The max dimensions of the card reader system are 130 x 80 x 50 mm There are 24 safety sensors The enlarged passenger width is 900 mm For the lengthened Speedlane a normally open mode is possible For description see chapter 4 Boon Edam B V Postbus 40 1135 ZG Edam Holland tel 0299 380808 fax 0299 372859 Version 10 2007 Issue SLBH GBR 7 Operating Manual 3 5 Multiple Speedianes optional Optionally a multiple Speedlane set up may be installed All Speedlane versions can be combined to a multiple installation 3 6 Activation options In the standard Speedlane a card reader system can be integrated The card reading system is located under the top plate Optionally a card sized insert can be fitted which is mounted flush with the top plate This insert indicates the position where to hold the access control card for identification To install the card reader system a space of 150 x 60 x 50 mm is reserved KI EE BOON EDAM Speedlane 900 Optionally a pedestal in front of the Speedlane can be mounted for the card reader system The max dimensions of the card reader system are 130 x 80 x 50 mm 3 7 Display options Optionally a LED display can be mounted in the
3. Pulse open ABERDEEN o Left LIT Intruder alarm On On Partial Off Error state Service item Indicates error state Encoder data Service item Displays encoder data Maximum authorisations 3 1 10 Buzzer On On Off Last action Open doors Open doors Close doors Default settings Service item Restore default settings Bs Y Escape Enter Right 10 2007 SLBH GBR Version Issue eeee BOON EDAM Speedliane 900 18 5 Maintenance Switch off the power of the door during maintenance or other work Do not use water near the drive unit or control boxes This schedule can be used as a checklist to maintain the Speediane in its correct condition Daily Check the emergency devices safeguards and the general operation of the Speedlane Weekly Cleaning of stainless steel parts e Clean these parts with a little water and a sponge e Dry these parts with a clean cloth e Spray Stainless Steel Polish amp Cleaner on the dry parts and rub them with a dry clean cloth Monthly Cleaning of stainless steel parts e Clean these parts with water and a sponge e Dry these parts with a clean cloth e Spra
4. 3 408 7255 F 34 0 93 408 3446 Boon Edam Tomsed Inc 402 McKinney Parkway LILLINGTON North Carolina 27546 United States of Amerika T 1 910 814 38 00 F 1 910 814 38 99 Boon Edam Japan Ltd 4th Floor Kyohachi Building 1 16 5 Shinkawa Chuo ku TOKYO 104 0033 Japan T 81 0 35117 26 51 F 81 0 35117 26 52 Beijing Boon Edam Entrance Technology Co Ltd No 10 Tong Ji Bei Lu Beijing Economic amp Technological Development Area BEIJING 100176 China T 86 0 10 67 87 77 66 F 86 0 10 67 87 78 05 Boon Edam Hong Kong Ltd 21 F New Word tower 1 18 Queen s Road Central HONG KONG T 852 0 258 32180 F 852 0 801 37180 Your Entrance Our Technology
5. DAM The Netherlands T 31 0 299 38 08 08 F 31 0 299 37 28 59 Boon Edam Nederland B V Ambachtstraat 4 1135 GG EDAM P O Box 40 1135 ZG EDAM The Netherlands T 31 0 299 38 08 08 F 31 0 299 38 08 41 Boon Edam Skauan A S Arnst Arnebergsvei 30 Postbox 430 N 1327 LYSAKER Norway T 47 0 67 10 3340 F 47 0 67 10 3344 Boon Edam Sweden AB Kutterv gen 3 S 183 02 T BY P O Box 2034 S 183 02 T BY Sweden T 46 0 8 753 60 30 F 46 0 8 753 61 30 Boon Edam LLC Leningradsky Prospect 39 Building 14 Floor 4 Room 416 125167 MOSCOW Russian Federation T 7 495 946 0249 Boon Edam Ireland Ltd Unit 1 Naas Road Business Park Muirfield Drive Naas Road DUBLIN 12 Ireland T 353 0 1 460 1420 F 353 0 1 460 1415 Boon Edam Ltd Holland House Crowbridge Road Orbital Park ASHFORD KENT TN24 OGR United Kingdom T 44 0 1233 505900 F 44 0 1233 505909 Boon Edam GmbH Lise Meitner Stra e 1 45659 RECKLINGHAUSEN Germany T 49 0 2361 58202 0 F 49 0 2361 58202 10 Boon Edam Belgi BVBA Welvaartstraat 14 1 Industriezone Klein Gent B 2200 HERENTALS Belgium T 32 0 14 21 67 17 F 32 0 14 21 67 29 Boon Edam France S A S ZA Les Doucettes 3 Avenue des Morillons 95146 GARGES LES GONESSE Cedex France T 33 0 1 30 11 05 05 F 33 0 1 39 86 71 10 e eeee BOON EDAM www boonedam com Boon Edam Spain S L C Pal ncia 14 16 1 4a 08027 BARCELONA Spain T 34 0 9
6. Stainless steel AISI 304 with a K240 grain finish plating material Stainless steel AISI 304 with a K320 grain finish end column Glass 10 mm transparent tempered 900 mm standard opt 1200 1400 1600 or 1800 mm 2x150 kg including glass standard version Chemical anchors Power supply operating panel optional fire alarm amp communication cables see drawings 240 VAC 50 60 Hz 16 A slow structural Input power when not used 30 Watt Maximum input power 350 Watt Asynchronous 3 phase motor 6 poles 3x240V 50Hz 0 25 kW ID 25 S3 per unit IP 54 135 degrees Celsius 900 rev min 15 1 Maximum 0 75 m sec Dead centre mechanism 16 bits micro processor Input 240 VAC 50 60 Hz Output 240 VAC 1 1 kVA 3 0A 0 55 kW 12 24 VDC 100mA 1m 10m 20 C 55 C 20ms Version Issue 10 2007 SLBH GBR eeee BOON EDAM Speedlane 900 22 Dimensions table D Ce Door wing heigth D Unit heigth 1030 approximately E Overall width 1270 Unit height is 1000 mm plus the thickness of the top H High L Long W Wide Boon Edam B V Postbus 40 1135 ZG Edam Holland Version 10 2007 tel 0299 380808 fax 0299 372859 Issue SLBH GBR Royal Boon Edam Group Holding B V Ambachtstraat 4 1135 GG EDAM P O Box 40 1135 ZG EDAM The Netherlands T 31 0 299 38 08 08 F 31 0 299 37 28 59 Boon Edam B V Ambachtstraat 4 1135 GG EDAM P O Box 40 1135 ZG E
7. ate unit is installed between the existing master slave Speedlane units This will create a double passage while saving space and costs This set up demonstrates why the glass door wings in the opposite units are always staggered All options available on the standard Speedilane are also available for the Multiple Speedlane set up It is possible to connect a wide and a standard Speedlane by a special intermediate unit This unit has a standard and a wide door panel Boon Edam B V Postbus 40 1135 ZG Edam Holland Version 10 2007 tel 0299 380808 fax 0299 372859 Issue SLBH GBR Operating Manual 3 Variations There are 8 standard variations of the Speedlane Type 900 900 H 900 W 900 L 900 HW 900 HL 900 LW 900 HLW Standard X Heightened X X X X Widened X X X X Lengthened X X X X 3 1 Standard unit The Speedlane can be activated by most access control systems These systems can be built into the column under the top panel in front of the LED display There are 16 safety sensors Total weight is 300 kg 3 2 Heightened unit The heightened Speedlane is available in 4 different heights to prevent climbing over The optional heights are 1200 mm 1400 mm 1600 mm 1800 mm Version 10 2007 Issue SLBH GBR KE BOON EDAM Speedlane 900 3 3 Widened unit 3 4 Lengthened unit
8. d 10 authorisations for each direction will be kept in memory Each authorisation has a maximum duration of 8 seconds This means that when a person passes the Speedlane the authorisation time is reset and the next person gets a maximum authorisation time of 8 seconds The door wings remain open until the last authorised person has passed the safety zone of the Speedlane Then the door wings will close immediately eeee ume ee BOON EDAM Speediane 900 10 4 2 2 Normally open mode optional for lengthened Speedlane The door wings are always open in the normally open mode The door wings stay open when an authorised person enters the Speedlane The door wings close when an unauthorised person enters the Speedlane When authorisation by means of a card reader proceeds more quickly then persons are passing the Speedlane a maximum of 3 default value adjustable between 1 and 10 authorisations for each direction will be kept in memory Each authorisation has a maximum duration of 8 seconds This means that when a person passes the Speedlane the authorisation time is reset and for the next person there is a maximum authorisation time of 8 seconds again The door wings remain open 4 3 Direction Types The following direction types can be selected by using the optional control panel MN Controlled access in both directions Access in both directions requires authorisation Each unauthorised movement constitutes an alarm situatio
9. e is 1200 1400 1600 or 1800 mm This height has been chosen to prevent people attempting to climb over the door wing The chosen width and opening and closing speed results in a capacity of up to 25 to 30 persons per minute in one direction depending on the authorisation system chosen In a fully open situation without authorisation the capacity can be increased to 120 persons per minute The maximum relative humidity is 75 which means that the Speedlane can be installed in all indoor environments The high maximum of 75 has the advantage that the Speedlane can easily be installed in humid environments Design The units consist of a frame incorporating the mechanics sensors and controls The frame design uses stainless steel features with a stainless steel column on each side The stainless steel features class AISI 304 with a grain K240 finish have been chosen for its attractive appearance The top surface has standard options like Oak wood lacquered Cherry wood lacquered or Stainless steel look a like veneer satin finish As a special other top plate materials are possible This gives architects the opportunity to fit the Speedlane to its environment The standard door wings are made of clear tempered glass eeee e BOON EDAM Speediane 900 4 Operation The Speedlane can be equipped with a control panel The panel is a separate unit and can be placed in on a reception desk The control panel can be used fo
10. eedlane still operates because of the uninterruptible power supply UPS If the battery of the UPS is low the door wings of the Speedlane will open and stay open default Alternatively the last action can be programmed to close the doors and to keep them closed When power is restored and the battery of the UPS is empty the Speedlane will initialise Otherwise the Speedlane will operate normally again Before the Speedlane is ready for use it needs to position its door wings The positioning of the door wings is done during initialisation While the Speedlane is initialising all security features will be disabled It is recommend to keep clear of the Speedlane during initialisation The fire alarm will also be disabled The door wings will open slowly in case of a fire alarm Once the fire alarm is cancelled the door wings will close The Speedlane is then ready for normal operation The fire alarm position always takes precedence over the locking position Installation and Maintenance Installation and maintenance have been kept as simple as possible Numerous maintenance free components have been used The Speedlane has also been equipped with easy removable panels This will save the service engineer lots of time The frame and columns can easily be installed and levelling is by means of adjusting bolts Multiple Speediane Set up Optionally a so called Multiple Speedlane set up may be installed In this set up an additional unit intermedi
11. enerated when the Speedlane is mechanically blocked during operation Anti masking detection The Speedlane has an anti masking detection Masking is the condition when one of the sensors is triggered covered continuously for more than 10 seconds When one of the sensors notices masking the acoustic alarm will be activated after ten seconds The alarm continues for three seconds This alarm will also be activated when a person stays to long in the detection sensors The alarm repeats after ten seconds Intruder alarm entry exit When an unauthorised person enters the Speedlane and activates one of the sensors the acoustic alarm is generated The alarm can be switched off or set to trigger when the intruder is in the safety zone Open door alarm When the door wings remain open an alarm is given after a number of minutes Boon Edam B V Postbus 40 1135 ZG Edam Holland Version 10 2007 tel 0299 380808 fax 0299 372859 Issue SLBH GBR 15 Operating Manual 4 8 Control Panel optional 1 When the block in push button is pressed the doors will remain shut even when an authorisation is given The opposite direction remains in operation 2 When the block out push button is pressed the doors will remain shut even when an authorisation is given The opposite direction remains in operation 3 When the pulse in button is pressed the doors will open and one person will be able to pass the S
12. h directions This is the default setting persons can be authorised for both directions Traffic mode in Secure direction Only persons passing in the Secure direction can be authorised The Non Secure side LED display shows a red cross X continuously Traffic mode in Non Secure direction Only persons passing in the Non Secure direction can be authorised The Secure side LED display shows a red cross X continuously 4 6 Feedback signals 4 6 1 4 6 2 Standard signalling default setting When the Speedlane initialises the display on both sides will be red X If initialising fails after three attempts the display on both sides will blink red X When the Speedlane is locked the display will be red X on both sides When the Speedlane is open the display on both sides will be green N When there is a fire alarm the display of the Speedlane will be green N on both sides When an unauthorised person enters the Speedlane the display on both sides will blink red X When an authorised person enters the Speedlane the display of the entering side will be green N If the person is in the Speedlane the display will be directly red X and the next person can be authorised If there are more authorisations pulse in push button is pressed more than once the display will become green turn red X when the person is in the Speedlane and become green N for the next authorised person when the first authorised per
13. in errors you can contact Boon Edam or your supplier He will be able to explain you how to operate the Speedlane Users of the Manual A person that has sufficient knowledge of the language used in the manual is allowed to execute maintenance This manual is aimed at the user of the Speedlane and provides information on e Operating the Speedlane e Maintenance e Trouble shooting Symbols You will encounter a few symbols in this manual The meaning of the symbols is as follows WARNING Risk of personal injury or loss of life NOTE The material may be damaged or the operation of the door affected Abbreviations Used MCB Microcontroller Board UPS Uninterrupted Power Supply FI Frequency Inverter N O Normally Open N C Normally Closed sg LED Light Emitting Diode CE Marking name tags and glass stickers The CE marking is placed at the inside of the master unit and directly visible when the top plate is removed There are two nametags One is placed at the non secured side at the bottom of the column One is placed at the secured side at the bottom of the column The two Boon Edam glass stickers are placed on the doorwings at the bottom on either side Boon Edam B V Postbus 40 1135 ZG Edam Holland Version 10 2007 tel 0299 380808 fax 0299 372859 Issue SLBH GBR 3 Operating Manual 2 Introduction 2 1 Concept and Design Application The Speedlane belongs to the security pr
14. ith slow speed y With authorisations in one direction only when an authorised person steps into the Speedlane and steps out the authorisation will remain active for 3 seconds adjustable 4 5 2 Medium security mode The medium security level is like the low security level only the area that is used to detect unauthorised persons is narrower This results in a higher level of tailgating prevention 4 5 3 High security mode When a person who has been authorised to enter the Secure Non Secure zone is closely followed by a second person who has not been authorised the authorised person will be allowed to enter The second person will not The door wings will close after the first person and a sound signal will be activated If the unauthorised person is in the safety zone the door wings will close with a slow speed In the Open on Detect mode the door wings will close on the person or object but if the door wings detect an obstruction they will open again A With authorisations in one direction only when an authorised person steps into the Speedlane and steps out the authorisation is void Boon Edam B V Postbus 40 1135 ZG Edam Holland Version 10 2007 tel 0299 380808 fax 0299 372859 Issue SLBH GBR 13 Operating Manual 4 5 4 Traffic mode It is possible to generate intelligent traffic control in case of a complete lane of Speedlanes The following settings are possible Traffic mode in bot
15. le connection power supply Check power supply and the fuses Reset by switching power off and power on Consult your Boon Edam Service Agent Version 10 2007 Issue SLBH GBR eeee BOON EDAM Speedliane 900 20 7 Components 5577 0011 TOP PLATE 5577 0003 CENTRE PLATE BACK SIDE 5577 0018 DOORWING GLASS 10 mm Boon Edam B V Postbus 40 1135 ZG Edam Holland tel 0299 380808 fax 0299 372859 5577 0005 REMOVABLE PLATES 5577 0002 CENTRE PLATE DOOR SIDE 5577 0000 END TUBE Version 10 2007 Issue SLBH GBR 21 Operating Manual 8 Specifications and dimensions Type Application Capacity Finish Door wing Door height Weight Installation Cabling Power supply Fuse Drive Input power Motor type Voltage Motor power Protective system Temperature sensing Motor speed Gearbox reduction Door speed Door lock Control Microcontroller Frequency inverter Nominal motor power Sensors Power supply Min distance Max distance Temp range Response time Two wing stainless steel access control barrier with sliding doors Barrier for controlled access supervision of people with a total height of 1000 mm excl top panel Controlled access 1 direction nominal capacity 25 to 30 persons min Combined controlled access in 2 directions Free entry exit nominal capacity 120 persons min
16. n Controlled access in one direction and free exit in the opposite direction Only one direction requires authorisation The other direction does not require authorisation provided no one attempts to pass the Speedlane authorised or unauthorised from the opposite direction MN Controlled access in one direction and blocked passage in the opposite direction Only one direction requires authorisation The other direction is permanently blocked In this situation the Speedlane can only be passed in a single direction thus creating a traffic control M Free access in both directions The Gpeedlane can be passed in both directions without authorisation It is recommended to select this mode by using the Open functionality M Blocked access in both directions The Gpeedlane cannot be passed 4 4 Card reader control When a person is authorised by the card reader for the Secure Non Secure zone entry the card reader gives a pulse to the control box of the Speedilane If the person then passes the door panels a booking pulse is given to the card reader controller if needed by the card reader control Boon Edam B V Postbus 40 1135 ZG Edam Holland Version 10 2007 tel 0299 380808 fax 0299 372859 Issue SLBH GBR 11 Operating Manual 4 5 Security When an unauthorised person steps in the Speediane a sound signal will be activated In normally closed mode the door wings stay closed and in normally open mode the door wings
17. n dE ee Ea 13 4 6 FEEDBACK SIGNALS jsccssconsev cutest de renesntnacaeadirecans tenuemtindiee a a te EERSTEN ek ere 13 4 6 1 Standard signalling default settimng cece cece eect ee eee eee e eens teens teens ea eeeneas 13 4 6 2 Alternative signalling sce esciesecensecices vende ta irea eaaeo taian 13 4 7 OTHER ALARMS 650 433 cea ctnava nna ecteansenncismes eer E eeh 14 4 8 CONTROL PANEL OPTIONAL eugvbNgesgergdgk ege g ER d ENNEN NEEN EEN E d ANNE ENER ENN 15 4 8 1 Other features of the control panel cece e eee eee teeta eee teeta ene teeta 16 4 9 ADJUSTMENTS SELECTION MENU 17 5 MAINTENANCE iiinc run anaa sods SE ee E a See ioleeessed 18 6 TROUBLE SHOOTING eege eebe ek E EERSTEN E SEENEN ES 19 7 COMPONENTS EE 20 8 SPECIFICATIONS AND DIMENSIONS ccccccee cece eee ence esas eeaeeeeaeenaee 21 Copyright This manual has been written and published by Boon Edam It is provided to users of the Speedlane and dealers of Boon Edam All rights reserved The information contained in this manual is the property of Boon Edam Transferring this information to third parties without prior consent of Boon Edam is prohibited eeee e BOON EDAM Speediane 900 2 1 Preface Read the Manual Please read this manual carefully before using the Speedlane for the first time Unclear Information The manual has been written with the utmost care and attention Nevertheless if certain parts are unclear to you or conta
18. oducts group of Boon Edam For an optimal security the Speedlane needs to be installed in an environment where supervision is present The Speedlane consists of two opposite units basic unit each of which has been equipped with a mechanism operating the glass door wings The door wings slide from a casing resulting in a standard position with completely blocked access normally closed The access width with both door wings fully opened is 510 mm This width is narrow enough to prevent two persons passing the Speedlane while walking next to each other The wide Speedlane has an opening of 900 mm for access of wheelchairs and trolleys The units are fitted with safety and security sensors which monitor persons passing the door wings and also perform a safety function The unit is 1000 mm high excluding the top plate Children lt 900 mm are not detected by the security sensors but are detected by the safety sensors between the doors The emphasis is on maximising safety and not on access security The safety sensors are placed between 180 mm and 580 mm to ensure optimal safety The total length of the standard Speedlane is 1395 mm the length of the lengthened Speedlane is 2580 mm This length is required for proper Secure interaction between the sensors and the sliding door wings in the normally open mode The height of the glass door wings of the standard Speedlane is 900 mm the height of the heightened Speedlan
19. of the control panel Global reset When the pulse in and pulse out buttons are pressed simultaneous during five seconds the Speedlane will reset The Speedlane will re initialise after which it is ready for use SECURED SIDE Master NON SECURED SIDE Slave Boon Edam B V Postbus 40 1135 ZG Edam Holland Version 10 2007 tel 0299 380808 fax 0299 372859 Issue SLBH GBR 17 Operating Manual 4 9 Adjustments Selection Menu To adjust the working of the Speedlane to its optimum a selection menu is built in The selection menu is visualised on a display on the control panel The selection menu is operated with the four push buttons directly under the display The table below gives all the menu items with the default settings and the setting range For the adjustment procedure please refer to the Electrical Service Manual Menu Item Default Range Signalling mode Standard Standard Alternative Security mode Low Low Medium High Open on detect Model selection Standard Standard Wide High Extended Wide High Wide Extended High Extended Wide High extended After selecting a High model the number of sensor pairs 1 to 5 must be chosen Door closing speed 4 1 4 Low security mode 1 1 Medium and High security mode Sensor usage All All Spare Entry time seconds 8 1 20 Hold time seconds 3 1 20 Reply time deci seconds 3 1 20 Gate open Sensor open
20. peedlane A maximum of 3 pulses adjustable is kept in memory 4 When the pulse out button is pressed the doors will open and one person will be able to pass the Speedlane A maximum of 3 pulses adjustable is kept in memory 5 When the free entry button is pressed no authorisation is needed for passing Normally closed mode o The door wings open when the person enters the Speediane o The door wings close after the person passes the safety zone except when a second person is already in the Speedlane Normally open mode o The door wings stay open o The door wings will close immediately and a sound signal will be activated when a person enters from the opposite direction 6 When the free exit button is pressed no authorisation is needed for passing Normally closed mode o The door wings open when the person enters the Speediane o The door wings close after the person passes the safety zone except when a second person is already in the Speedlane Normally open mode o The door wings stay open o The door wings will close immediately and a sound signal will be activated when a person enters from the opposite direction 7 While the open button is pressed the doors will open and remain open When the button is pressed again the doors will close and operate in the normal way 8 Alarm light 1 3 5 7 2 4 BOON EDAM 6 8 ss Version 10 2007 go tae BOON EDAM Speedlane 900 16 4 8 1 Other features
21. r a number of functions The door wings can be locked in the open or closed position but can also be fully opened The control panel has been provided with push buttons to allow a single person to pass in either direction or to allow persons to pass continuously The Speedlane itself can be equipped with a card reader system not delivered by BE Optionally the card readers can be integrated into the Speedlane It is also possible to place an additional card reader pedestal in front of the Speedlane which is identical to the ones used at the ends of the Speedlane Safety and security Safety has been the top priority in the development of the Speedlane It passed our rigorous CE procedure The extremely fast electronics in combination with the sensors described above make the Speedlane a very safe product Three different security modes can be selected low medium or high security mode In the low security mode when a person or object is in the safety zone between the two door wings the door wings will not close When the door wings are already closing they will stop and open slowly The medium security level is like the low security level only the area that is used to detect unauthorised persons is narrower This results in a higher level of tailgating prevention In the high security level open on detect the door wings will close on the person object but if an obstruction is detected they will open In case of a power failure the Sp
22. son has left the Speediane After the last authorised person the display will be red X and the doors will close Alternative signalling When the Speedlane initialises the display on both sides will not be lit If initialising fails after three attempts the display on both sides will blink red X When the Speedlane is locked the display will be red X on both sides When the Speedlane is open the display on both sides will be green N When there is a fire alarm the display of the Speedlane will be green N on both sides When an unauthorised person enters the safety zone of the Speedlane the display on both sides will blink red X When an authorised person enters the Speedlane the display of the entering side will be green N for one second If the person is in the Speedlane the display will be directly red X and the next person can be authorised If there are more authorisations pulse in push button is pressed more than once the display will become green N for one second turn red X when the person is in the Speedlane and become green N for one second for the next authorised person when the first authorised person has left the Speedlane After the last authorised person the display will be off and the doors will close Version Issue eeee eas BOON EDAM Speedliane 900 14 4 7 Other Alarms Malfunction alarm When the Speedlane fails to initialise an alarm is generated The alarm is also g
23. stainless steel column on each side of the Speediane The display is visible via two slots The display can light up red or green The display can be used to display traffic indication signals or authorisation signals Boon Edam B V Postbus 40 1135 ZG Edam Holland tel 0299 380808 fax 0299 372859 9 Operating Manual 4 Operating Concept 4 1 Introduction The Speedlane consists of two opposing units The barrier is formed by two sliding doors In a single Speedlane each unit is equipped with one sliding door In a set up with multiple adjacent Speedianes each unit except for the outside ones is equipped with two sliding doors A number of specific alarms are raised in case of unauthorised use 4 2 Standard operation 4 2 1 Normally closed mode default setting Secure A person is given authorisation by presenting a proximity card to the access control system or when the push button is pressed depending on the authorisation system chosen When an authorised person enters or is already in the Secure Non Secure zone the door wings will open After the person has passed the safety zone the door wings will close immediately When no one passes through the Speedlane the door wings will close after 8 seconds maximum authorisation time When authorisation by means of a card reader proceeds more quickly than persons are passing the Speedlane a maximum of 3 default value adjustable between 1 an
24. will close When the person is standing in the Secure Non Secure zone and authorises the door wings will open When an unauthorised person is standing in the Speedlane Secure Non Secure or safety zone and a second person approaches from the opposite direction the second person cannot be authorised The first person needs to leave the Speediane before the second can be authorised When an unauthorised person is standing in the Speedlane and a second person is approaching from the same direction the second person can be authorised The first person has to leave the Speedlane at the side the other person is approaching to allow the second person to pass When the unauthorised person does not step out this person can pass the door wings using the authorisation of the second person The second person then needs to be authorised again to be able to pass the Speedlane KE e BOON EDAM Speedlane 900 12 4 5 1 Low security mode default setting When a person who has been authorised to enter the Secure Non Secure zone is closely followed by a second person who has not been authorised the authorised person will be allowed to enter The second person will not The door wings will only close after the first person when the second person is not in the safety zone A sound signal will be activated If the door wings are closing and the unauthorised person steps in the safety zone the door wings will stop directly and open w
25. y Stainless Steel Polish amp Cleaner on the dry parts and rub them with a dry clean cloth Yearly Once a year the Speediane needs a major maintenance service This service should be carried out by Boon Edam or by an authorised dealer Boon Edam B V Postbus 40 1135 ZG Edam Holland Version 10 2007 tel 0299 380808 fax 0299 372859 Issue SLBH GBR 19 Operating Manual 6 Trouble Shooting work Switch off the power of the door during maintenance or other Use for replacement original parts so that a correct operation is guaranteed Mechanical MALFUNCTION POSSIBLE CAUSE CORRECTIVE ACTION Unusual noises gt Mechanical components loose or faulty 7 Find the cause of the noise Consult your Boon Edam Service Agent Electrical MALFUNCTION POSSIBLE CAUSE CORRECTIVE ACTION Speediane stays locked Speediane does not stay locked Doors are in half open position gt Power supply Control system failure Power supply Fire alarm Panels out of position Processor malfunctioning Check power supply and the fuses Reset by switching power off and power on Consult your Boon Edam Service Agent Check cable connection power supply Check power supply and the fuses Reset by switching power off and power on Check mechanism Consult your Boon Edam Service Agent Check cab