Home
Smart Handle Pro Manual PDF
Contents
1. ROLYAN SMART HANDLE Step 1 Press and hold the POWER button for 2 seconds to power on the device The LCD display will show the software version and initialize settings when complete default then turn to measurement display status 8888 U 102 Ink gt 00 Step 2 Press and hold the MENU button for 2 seconds to access the mode selection Press UP DOWN button to select the desired training mode or setting mode o Training Mode GERE GERE ERSA BERA Peak Force Target Force Repetition Rep amp Target Force Training Training Training Training o Setting Mode F 4 F 5 F 6 F 7 Wireless Volume Control Unit Setting ID Setting Transmission factory use only Step 3 Start the resistance exercise After the user completes a full repetition concentric force e g pull gt 1kg and eccentric release lt 0 5kg as a cycle the device will beep and keep the peak force on the display Step 4 When a set of exercises is complete to transmit the exercise data press and hold the BLUETOOTH button for 2 seconds The data of the last set is transmitted via Bluetooth to the smart phone tablet Make sure the Bluetooth function is open on OS Android system prior to use See BLUETOOTH TRANSMISSION section for further settings 20 a PATTERSON MEDICAI Once the BLUETOOTH button is being pressed and held the device will show the Bluetooth symbol and make the Rolyan smart handle searchable The LCD dis
2. 090000000 For App support in the US please contact Patterson Medical ON 800 343 9742 For all other countries please contact your local Patterson Medical country office 27 LPs PATTERSON MEDICAL 7 SPECIFICATIONS Trade Name Model Name Software Version Power Supply Adaptor Optional Dimension Weight Battery Life LCD Force Range Unit Band Thickness Limit Maximum Recording Power Saving Wireless Transmission Compliances Operation Condition Storage Condition Rolyan Smart Handle Pro ZSH RP Pro v1 0 3 7 V 900mAh Lithium ion Battery charged by USB to DC Jack charging cable GlobTek GTM41078 0605 USB 100 240V 50 60Hz 0 3A Output 5VDC 1 2A 6W L6 02 xW5 31 xH0 98 L153 mm x 135 mm x 25 mm Main Handle 324 g Dumb Handle 229 g up to 100 hours of use on a full charge Capacity Indicator mam gt 50 TM 50 20 E 20 5 flashing lt 5 flashing White Backlight L1 02 xW0 49 L26mmxW12 5mm 0 50 Ib 0 22 7 kg 0 222 5N Ib kg N 0 1 mm 1 2mm 1000 cycles per exercise If idle for 30 sec the LCD backlight automatically turns off If idle for 2 min the system automatically turns off lt 10m for OS devices Bluetooth 4 0 is required N 7 N for Android device Bluetooth 2 0 or above is required MDD 93 42 EEC Class I IEC60601 1 2005 IEC60601 1 2 2007 FCC ID PDSZSHRP201400YPM 0 to 40 C 32 to 104 F 90 R H under
3. F 1 Use to provide feedback to patient that target force is achieved This mode enables the patient and you to receive audio and or visual feedback each time the specific strength exercise resistance dosage is met or exceeded This mode is particularly beneficial when the peak force occurs toward the maximum elongation of the elastic band Therefore the patient is prompted to move through his her full ROM while exercising Example Using the same exercise data as in MODE F 0 chose the color elastic band that offers around 15 to 20 Ibs of resistance Anchor the ends of the band so that a single repetition provides 18 lbs of force NOTE use Mode FO to determine this Once the band color and length is determined using Mode F 1 enter the peak force target of 18 lbs Have the patient exercise to momentary fatigue or for a set number of repetitions SEE Mode F 2 and Mode F 3 MODE F 2 Use to set repetition targets Enter the number of repetitions you want your patient to perform for the set of exercise This mode is used when you want a particular limit on the number of repetitions a patient performs and do not want them to exercise to momentary fatigue 22 Ss PATTERSON MEDICAL Tip In the F 2 Rep mode the tension must be completely removed lt 0 5kg to register an effective repetition For some exercises like stand hip abduction we suggest first test patient s range of motion to adjust the proper length of band and the
4. 8 to 12 repetitions of a strength exercise the resistance is roughly 70 to 80 of one repetition maximum 1RM This intensity is recommended in many clinical exercise guidelines as it represents a level of difficulty that is not too stressful to patients yet sufficient to generate rapid strength gains The Rolyan smart handle helps therapists to determine an actual 1RM value used to calculate the specific targeted exercise intensity For example if the patient s 1RM is 5kg 11lbs and the prescribed exercise intensity is 80 of RM then the initial resistance load is 4kg 9lbs In addition research demonstrates that resistance must be progressed for muscles to strengthen So progressive increases in resistance levels are necessary over subsequent exercise sessions The Rolyan smart handle enables these increases to be made systematically and accurately Let us look at how this is accomplished 70 to 80 of a 1RM is challenging enough so that when exercising at that intensity most people experience momentary muscle fatigue between 8 and 12 repetitions If exercising to momentary fatigue a patient demonstrates increased strength when they perform more repetitions at the same resistance level If initially a patient fatigues between 8 and 12 repetitions and during a subsequent exercise session performs more than 12 repetitions the intensity is then less than the target intensity of 70 to 80 of a 1RM Therefore after 12 or more repetitions th
5. Non condensing 10 to 40 C 14 to 104 F 90 R H under Non condensing 40 to 50 C 104 to 122 F 70 R H under Non condensing 28 Ss PATTERSON MEDICAL 8 TROUBLESHOOTING Error Message Restart the system if the error still Internal Power Failure happens call your local distributor or agent for repair Restart the system if the error still happens call your local distributor or agent for repair Bluetooth Module Failure For detailed troubleshooting please refer to the service manual 29 9 MANUFACTURED FOR EU REPRESENTATIVE DISTRIBUTORS amp Warranty Manufactured for ul Patterson Medical Supply Inc W68 N158 Evergreen Blvd Cedarburg WI 53012 USA Telephone 800 228 3693 Fax 262 387 8748 Web www pattersonmedical com Email customersupportO pattersonmedical com Authorised Representative in the European Union Patterson Medical Ltd Nunn Brook Road Huthwaite Sutton in Ashfield Nottinghamshire NG17 2HU UK UK telephone 08444 124 330 International telephone 44 1623 448 706 Web www pattersonmedical co uk 30 a PATTERSON MEDI A I Fr PATTERSON MEDICA I Distributors Patterson Medical ANZ Unit 3 3 Basalt Road Pemulwuy NSW Australia 2145 Patterson Medical Canada 6675 Millcreek Dr Unit 3 Mississauga ON L5N 5M4 Canada Patterson Medical France Zone Industrielle de Montjoly 11 Avenue de I Industrie CS40712 08013 Charlev
6. Rolyan Smart Handle Pro User Manual K PATTERSON MEDICAL TABLE OF CONTENTS INTRODUCTION THERAPY ADVANTAGES OBJECTIVITY BIOFEEDBACK CONTROL DEFENDABLE DOCUMENTATION CLINICAL BENEFITS SAFETY PRECAUTIONS MAINTENANCE PRODUCT COMPOSITION ROLYAN SMART HANDLE PRIMARY COMPONENTS CONTROL PANEL LCD DISPLAY BAND GRIP RANGE LABELLING INSTALLATION FOR USE INSTALLATION OF ACCESSOIRES INSTALLATION OF BAND OPERATION INSTRUCTIONS ROLYAN SMART HANDLE HOW TO APPLY THE VARIOUS MODES TO CLINICAL PRACTICE BLUETOOTH TRANSMISSION SPECIFICATIONS TROUBLESHOOTING MANUFACTURED FOR EU REPRESENTATIVE DISTRIBUTORS amp WARRANTY Fa PATTERSON MEDICAL WO CON DU UV WwW w DN WN Nm NN NPP PA RP C4 PR RP PR pn OOO0O HINOGQ 0SN OU pun PO LE A PATTERSON 1 INTRODUCTION MEDICAL The Rolyan smart handle is designed to promote high quality therapeutic exercise for physiotherapy patients members of fitness wellness centers and those exercising at home Used with elastic exercise bands the Rolyan smart handle is a practical and simple digital interface for resistive exercise When used by therapists the Rolyan smart handles provides real time feedback by displaying force and repetition data This enables therapists to see and record the specific data needed for reliable evidence based exercise programs that help maximize patient strength and function in the shortest period of time possible Use the Roly
7. an smart handle to Guide strengthening exercises Objectively measure and set precise resistance levels Count and indicate the number of repetitions of a specific exercise O O O Encourage quality exercise by setting resistance targets and using immediate audio amp visual signals to cue range of motion and resistance targets O Wirelessly transmit performance data from the Rolyan smart handle to your Bluetooth enabled computer O Record detailed exercise information to document skilled therapy services For additional information and online education please visit www pattersonmedical com a 4 PATTERSON 2 THERAPY ADVANTAGES MEDICAL OBJECTIVITY Therapists constantly face challenges that limit their ability to help patients achieve therapy goals Limited treatment times an insufficient number of patient visits and capped payments can all affect successful patient outcomes It is therefore vital that the therapist provides evidence based treatments that are designed to maximize patient outcome in the shortest period of time Resistance exercises with elastic bands designed to improve muscle strength are one of the most essential and frequently provided forms of physiotherapy treatment Research demonstrates that excellent muscle strengthening is achieved when specific exercise parameters including body limb position and range of motion are precisely replicated each time the exercise is performed Most critically the
8. and get started Android Get into general settings to turn Bluetooth on and pair with Rolyan smart handle first settings Wireless amp Meterorks Bluetooth JON z Devices wehin Now Discoverabia Pair Rolyan smart handle with your smart phone pad tablet for Android system only O 3 51 pm Bluetooth Bluetooth pairing request Bluetooth g pair with O eto pair Smart_Handle Paired devices Paired devices Type the device s required PIN Available devices Searching 0000 Smart Handle Usually 0000 or 1234 Smart Handle Rename Smart_Handle 0010 Cancel Search for devices Rename phone Advanced Visibility timeout Show received files CET For the first pairing press and hold Bluetooth button on the Rolyan smart handle for 2 seconds to make it searchable Find and click the function of Search for devices to search available devices Click Smart Handle and type the PIN 0000 to pair with your smart phone tablet Once the device paired tap APP to open it and get started 24 7 Add Profile FALTERSON Click icon to create a new user s profile Input the user identifier ID and Weight Click icon to edit or delete the profile Barsimeo La Pera Hubert Heyde Roseline Devereaux Tofio Jagannatha Will Zeigner BAR pgi Get Data Click icon to establish the connection with device make sure the Bluetooth button on Rolyan smart handle is being p
9. atus for wireless connection Newton increment by 1 N Pounds increment by 0 1 lb Kilograms increment by 0 1 kg Digital display of measured force 14 LPs PATTERSON MEDICAL BAND GRIP RANGE O The Rolyan smart handle has been designed to grip resistant bands with a specific thickness between 0 17 to 1 2mm to perform the progress training The Rolyan smart handle has been designed to grip single layer resistant band the thickness should remain between 0 17 to 1 2mm The band can be folded at the edge if the width exceeds 11cm 4 1 3 Ensure the band is secure and the clip is locked To avoid slipping risk due to band overstretch make sure to retain a safe grip length about the width of a hand palm on the lose end of the band when fastening the band into the grip Note Do not overstretch the elastic band by more than 3 times its resting length Example a 30cm 12 band should not be stretched to more than 90cm 35 total length 15 F r PATTERSON MEDICA I LABELLING Pl COS ER olyan Smart Handle Pro n Model Name ZSH RP DE Inputt SV 3A F2 Repetition Resistance Serial Number RP3XXXXX oco Manufactured for ES Combo Target Rep Patterson Medical Products Inc F4 Bluetooth Setting W68 N158 Evergreen Blvd Cedarburg WI 53012 USA ae EM Volume Control 0 1 5 EU Authorised Representative Y F6 Unit Setting N Ib kg EC REP Patterson Medical Ltd ID Setting 0000 9999
10. e resistance should be increased The challenge is to know when to increase the resistance and by how much Research suggests that when progressing resistance for those exercising from 70 to 80 of a 1RM the appropriate amount of an increase is 5 An increase of 5 usually results in patients performing no fewer than 8 repetitions during the subsequent exercise session Limiting the increase to 5 helps protect patients from over exertion and ensures that they continue to exercise at the resistance range dosage of 70 to 80 of 1RM Fa PATTERSON MEDICAL Here s an example of how objective data from the Rolyan smart handle can provide the objectivity necessary to present high quality evidence based strength exercise A patient performs elbow flexion with the Rolyan smart handle During the initial exercise session the therapist determines that the appropriate resistance for the patient is 5 kg 11 Ibs The patient fatigues during the y repetition Because this is fewer than 12 repetitions the resistance is kept the same at 5 kg 11 Ibs during the next exercise session When performing the same exercise during the second exercise session the patient fatigues during the 14 repetition Since this is more than the 12 reps for the third exercise session the resistance for the exercise is increased by 5 x 1 05 to 5 25 kg 11 5 Ibs The therapist chooses either a stronger level of band or sets the length of the band within the R
11. ents inherently encourages the performance of good quality exercise The Rolyan smart handle provides patients with exercise targets guiding them with audio cues when resistance and or repetition goals are achieved thus promoting high quality resistance exercise DEFENDABLE DOCUMENTATION Health Services governmental agencies and medical insurance companies have steadily increased therapy documentation requirements They want to see objective data that reflects progress or lack thereof This includes an increased focus on Therapeutic Exercise therapy procedures with reviewers closely scrutinizing if exercises are skilled in nature versus rote unskilled activities The Rolyan smart handle provides essential detailed resistance data and repetition figures that can be recorded at each therapy session to reflect the mindful and skilled therapy services provided to govern strength exercise The reports produced by the Rolyan smart handle clearly show the patient s progress and can be printed out and when required attached to the patient s record The results of each strength exercise can be downloaded from the Rolyan smart handle directly to a Bluetooth enabled device such mobile phone or tablet The captured information efficiently and effectively guides therapists to better tailor a patient s treatment plan based on the logical progression of strength exercises This level of detail can result in optimal therapy results shorter time to maximal pa
12. gt Rolyan smart handle and resistive elastic bands are not toys consult a physician or therapist before allowing children to exercise with elastic FAS lt T TT i FR resistance bands M N u _A y y IN With any exercise program muscle soreness may be experienced over the first few days If considerable muscle soreness persists for more than 3 4 days consult your physician or therapist Do not exercise if Vo experiencing pain If you experience sharp pain shortness of breath dizziness or light headedness with any of these exercises stop immediately and contact your healthcare provider MAINTENANCE o Always inspect the band before use for small nicks tears or punctures that may cause the band to break If you find any flaws discard the product and replace before performing any exercises For band maintenance please follow its manufacturer s instructions o Store the Rolyan smart handle and accessories out of direct sunlight and away from extreme temperatures o After each use wipe the Rolyan smart handle with a clean damp cloth 10 11 IID PATTERSON MEDICAL PRIMARY COMPONENTS 1 Door Anchor 2 Extremity Strap 3 Dumb Handle 4 USB to DC Jack charging cable 5 DC Charger optional 6 Webbing handles optional For safety please select the DC charger recognized in compliances with IEC60601 1 Requiremen
13. ille M zieres Cedex France Warranty The Rolyan smart handles are fully self contained units which provide many years of accurate dependable service to the user The Rolyan smart handles are warranted for 12 months 1 year from date of purchase against faulty workmanship or materials The warranty is limited to repair or replacement of defective product Patterson Medical is not responsible for any damage or injury caused by misuse or non observance of the instructions set out in this manual Should you experience any questions or problems regarding this instrument please contact Patterson Medical your distributor or an approved agent Should it be necessary to return the Rolyan smart handle it is essential it is adequately packed to protect it in transit preferably in its own purpose made original box otherwise Patterson Medical cannot accept any responsibility for transit damage to the unit Full details of your Patterson Medical country office can be found on page 31 to 320f this manual 31 32 33 34
14. intensity of the exercise resistance level must be sufficiently challenging to the patient and as the patient strengthens over time the resistance increased In other words to be effective the exercise must be both consistent and progressive the term Progressive Resistance Exercise PRE a well known method of increasing the ability of muscles to generate force has been also demonstrated to be a safe and efficacious intervention for many patients with muscle force deficits contributing to their motor disability in physical therapy Keeping track of specific exercise resistances is easy when using cuff weights dumbbells and weight machines because the amount of resistance or weight is usually clearly labeled However this objectivity currently does not exist when using resistive elastic bands When having patients exercise with elastic bands the Rolyan smart handle helps therapists simply and quickly determine specific exercise resistance by displaying the actual forces generated during each exercise When attached to the resistive elastic band the Rolyan smart handle displays the peak force generated by the patient or therapist during a single repetition This information provides the therapist with detailed information needed to determine the optimal resistance appropriate for that exercise and patient Fa PATTERSON MEDICAL Strength exercise research suggests that when a patient momentarily fatigues a muscle group between
15. n install the band on the Rolyan smart handle to avoid repeated band installation MODE F 3 Use to set both target force and repetition This mode enables you to set both the target force and the repetition goal for the specific exercise This mode is used when you want a particular limit on the number of repetitions do not want patient to exercise to momentary fatigue but do want to motivate them to achieve a specific peak force target for each repetition Example of Evaluation Sheet For some clinical environments which don t have the smart phone tablet the blank evaluation sheet is also now available to download at www pattersonmedical com User can print this sheet to record each exercise protocol in different prescriptions and dates EXERCISE 70 80 of 1RM DATE 204 2 11 2 13 2 18 2 20 2 22 225 Elastic resistance Ib Use cuff attachment on wrist 17 22 i Terminal Knee extension Right leg iht Elastic resistance lb Te fs Medium Bolster under knee Encourage full extension 23 a A PATTERSON BLUETOOTH TRANSMISSION MEDICAI Download App Find Rolyan Smart Handle Pro APP on the Google Play APP Store and install the APP on the device Required iOS Required Android 6 0 or above 4 0 3 or above Required Bluetooth Required Bluetooth 4 0 2 0 or above gt Google play Available on the A App Store Turn Bluetooth on OS Get into general settings to turn Bluetooth on Tap APP to open it
16. olyan smart handle so the new resistance is level can be set at 5 25 kg This is precise dosing of resistance helps optimize both patient safety and treatment outcomes BIOFEEDBACK People typically perform at a higher capacity when they receive useful feedback relevant to their performance Therapy patients are no different The Rolyan smart handle provides patients with specific feedback a The peak force of each repetition b The number of repetitions performed c Adjustable audio signals amp synchronously visual signals to cue the patient when repetition or peak force targets are achieved Furthermore patients are naturally engaged and motivated by technology While resistive elastic bands are low tech products and may be perceived by some patients as very simple form of exercise they are none the less a very economical and user friendly exercise tool The Rolyan smart handle not only adds clinical value but sophistication to band exercise thereby influencing patient perceptions and enhancing the professionalism of a therapy clinic LE A PATTERSON MEDICAL CONTROL Without close oversight and detailed monitoring patients performing strength exercises with resistive elastic bands often use poor technique this can be in the form of incomplete range of motion inadequate or excessive resistance and or improper body limb position and substitute movements The Rolyan smart handle technology along with the band attachm
17. ound when the clip is locked Fa PATTERSON MEDICAL When using the accessories such as the door anchor or the extremity cuff make sure the accessory is fixed securely between the door and the door frame Always position the exerciser so that the door opens away from the user If the door has a lock lock it to prevent unexpected door opening by another person Tug on the anchor to test for stability before exercise to make sure the anchor does not slip during exercise Always use a fresh piece of band for each and every exercise session To avoid excessively high resistance levels do not use a band that is too short The minimum band length between the grips should always be greater than 30cm 12 Some brands of exercise bands have a fine wax bloom or powder coating on the surface this is to preserve the band and this coating can affect the grip Follow the band manufacturer s instructions for cleaning any surface contamination from the band If the resistance band is slipping from the band clamp use a light wipe with alcohol isopropanol to clean the inside face of the clamp grips NEVER APPLY ALCOHOL OR OTHER ORGANIC SOLVENTS DIRECTLY ON THE BANDS only on the clamp grip surfaces If the clamp mechanism or the clamp faces are damaged in any way contact your local Rolyan smart handle agent for repair Do not overstretch bands by more than 3 times its resting length Example a 30cm 12 band should not be stretched to mo
18. p Using palm instead of fingers to press and rotate the hard piece of attachment is easier Fr PATTERSON MEDICAL o Door Anchor Fix on the Door Gap Fix on the handle For safety place the door anchor between the door and the door frame Always position the exerciser so that the door opens away from the user If the door has a lock lock it to prevent unexpected door opening by another person Tug on the anchor to test for stability before exercise to make sure the anchor does not slip during exercise o Upper Lower Extremity Strap Fix on the handle Fix on the limb ZK vA k For safety please make sure the hook and loop are firmly attached For the people who suffer from muscular dystrophies diseases or muscle weakness it is highly recommended to use extremity strap instead of handle to hold the device 18 gt PATTERSON MEDICAL INSTALLATION OF ELASTIC BAND Step 1 Locate the locking clip on the Rolyan smart handle and use your thumb to open up the Locking Clip Step 2 Place the resistant band between the clamp and locking clip For safety the band should always extend beyond the clamp by at least the width of a palm Close the Locking Clip by index finger to lock the clamp until hearing it click Step 3 Repeat the same procedure for the dumb handle 19 Far PATTERSON MEDICA I 6 OPERATION INSTRUCTIONS A MAKE SURE THE BATTERY IS FULLY CHARGED PRIOR TO FIRST USE
19. plays the sequence as below er Jla IDLY ISL a ee cL IL gt b Once the Bluetooth Device has been connected the LCD displays P and then returns to the default display when the transmission is complete If the connection fails the LCD displays noP and returns to the default screen in few seconds Bll poe Ti m 0 PEAKITA Step 5 Always press and hold the SET RESET button to clean previously recorded data before starting a new set of exercises The display shows rSt reset when the data is being cleaned mu PEAK TARGET AP Note When the device idles over 30 seconds the LCD backlight will dim but the unit is still active When the device idles over 2 minutes the unit will automatically shut down to save battery power and clean the recorded data Be sure to export the data to mobile phone tablet to avoid data loss 21 LPs PATTERSON MEDICAL HOW TO APPLY THE VARIOUS MODES TO CLINICAL PRACTICE MODE F 0 Use to calculate specific exercise intensity dosage Ib kg N Perform a single repetition through the full range of motion ROM The peak force is displayed wherever it occurs in the ROM Multiply that figure by the desired strength exercise intensity to calculate the target peak force Example Peak force during the repetition is 22 2 lbs The exercise intensity is 80 of 1 RM Therefore the exercise specific resistance dosage is 22 2 x 0 80 17 8 lbs approximately 18lbs MODE
20. r en Huthwaite Sutton in Ashfield potte A Be sure the band is securely anchored to a sturdy ECC ID POSZSHRP201400YPM De na sets by more than 3 times Compliance with IEC60601 1 amp 1EC60601 1 2 i A its h y This device complies with part 15 of the FCC Rules R edel Engt Operation is subject to the following two conditions A Band Thickness 0 17 1 2mm i Fi This device may not cause sii interference and e EN 3 x 2 This device must accept any interference received including interferente IN Force Range 0 50lb 0 23kg 0 222N o a a ves allan Made in Taiwan Attention Consult instructions for use Bluetooth Inside BF type applied part grip Manufacturer and Manufacturing Date European Union Directive on Waste from Electrical and Electronic Equipment xE a e bs CE compliance mark EU Authorized Representative Bl AA al Mm RoHS compliance as a I u 16 PID PATTERSON MEDICA 5 INSTALLATION FOR USE INSTALLATION OF ACCESSORIES Each attachment has a Y shaped KEY structure see pictures below User can easily find the arrow mark on the key and the surface of socket Y shaped Key Socket o Installation Plug the key arrow pin into the Socket from either start end of arrow and then press and rotate 60 to lock the KEY along the direction of arrow o Uninstallation Press and rotate 60 to release the KEY and then pull up the attachment Ti
21. r to lose balance and fall if the band attached to the Rolyan smart handle should suddenly snap or slip during the exercise Avoid any exercise that could cause the patient s limbs to move back rapidly and hit a close object or person should the band attached to the Rolyan smart handle suddenly snap or slip during the exercise The Rolyan smart handle is meant to be used as an attended therapy The therapist should be present to assure therapy regimens are followed as well as safety protocols The Rolyan smart handle is not a toy and should not be left alone with children present The Rolyan smart handle and its accessories can act as projectiles when the band is stretched Make sure no one is in direct proximity while the product is being used to avoid injury Letting go of the Rolyan smart handle while is use can damage the device Inspect the resistive band before use for small nicks tears or punctures that may cause the band to break If you find any such damage in the resistive band discard it and replace with a new band before performing any exercises Always examine the surface of the bands for signs of damage i e cracks or tears before use Ensure a proper length of band to provide better user control and to avoid high pull forces Never use bands that have been cut down in width Make sure the resistive band is securely gripped and locked in the Rolyan smart handle or its attachment before use i e you will hear a click s
22. re than 90cm 35 total length Do not use the Rolyan smart handle while charging the battery The system will beep and automatically turn off when the charge signal is detected Do not tamper with the casing or change remove any of original parts This will VOID the warranty Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment ED a PATTERSON PATTERSON PRECAUTIONS MEDICAI MEDICAI 4 PRODUCT COMPOSITION N Always consult a physician or therapist before starting any exercise program ROLYAN SMART HANDLE PRO 1 Control Panel 2 Band Clamp 3 Locking Clip N U S Food and Drug Administration warns that Radio Frequency Identification Devices can cause malfunctions in Pacemakers and Cardioverter Defibrillators The Rolyan smart handle can wirelessly transfer exercise data via Bluetooth transmission at Radio Frequency o 4 Charge Indicator Please keep a minimum separation distance of 2 5cm when using the l o 5 Operation Indicator Bluetooth transmission 6 Attachment Connector 7 LCD Indicator 8 Up Down Button For patients your physician or therapist should develop an 9 Data Connector N To prevent possible disruption of function keep Rolyan smart handle at least 10 feet from microwave or shortwave diathermy equipment gt individualized exercise program to meet your needs and abilities 10 Charge Connector
23. ressed and select the device to wirelessly get the training data via Bluetooth Click icon to edit device name Will Zeigner MAX Rolyan Smart 2014 07 17 06 09 19 PM Kg 2014 07 17 06 07 47 PM Kg 2014 07 17 06 07 09 PM Kg 2014 07 17 06 03 07 PM Kg 7 Getting data 2014 07 17 06 01 04 PM Kg 25 LPs PATTERSON Edit Data MEDICAL When the data is successfully received select the training detail including body part training type and band color and click X to save Shoulder Flexion Left Arms Flexion Right Left View Data When the training detail has been set user can view the data set on the screen Click icon to delete the data Click 14 icon to export data either in excel or photo format e 2014 07 0 4 so 0 1 Excal Photo Cancel 26 Ss PATTERSON Export Data MEDICAL There are three ways to export data single user single data set single user multiple data sets and multiple users multiple data sets Click 14 icon to export data in excel or photo format Single user single data Single user multiple data Multiple user multiple data Will Zeigner 2014 07 17 Will Zeigner MAX 0003 Average 0 4 sec Ko Calories 0 tkcal 2014 07 17 06 09 19 PM Kg Barsimeo La Pera 3 435 2014 07 17 06 07 47 PM Kg Hubert Heyde nak Roseline Devereaux 2014 07 17 06 07 09 PM Kg 3 439 To o Jagannatha 2014 07 17 06 03 07 PM Kg Will Zeigner MDR are 2014 07 17 06 01 04 PM Kg
24. tient function and better clinical patient outcomes overall Ss PATTERSON MEDICAL For example Compare these two patient therapy notes describing a single strength exercise 1 Elbow flexion performed with green band 2 sets of 10 Increased resistance from red band last week 2 Elbow flexion performed with blue band using 3 15kg 6 9 Ibs of resistance Patient receiving cues to insure full repetition each repetition Resistance increased from 3 kg 6 6 Ibs last week CLINICAL BENEFITS The Rolyan smart handle can be used as part of an exercise program to o Improve muscle strength O Improve gait o Improve muscle power Enhance grip strength O o Improve range of motion o Improve cardiovascular function o Improve posture o Increase blood circulation o Improve balance and proprioception 7 A PATTERSON SAFETY MEDICAL The Rolyan smart handle should only be used with good quality resistive bands designed to withstand the forces being applied Check with the band manufacturer to ensure your band is appropriate for your intended use Always follow the specific safety directions issued by exercise band manufacturer Be extra cautious when using exercises that involve stretching the resistive band toward the face and head as sudden release of tension could cause injury to the face or eyes Protective eyewear should be worn if performing this type of exercise Avoid any exercise that could cause the patient or band use
25. ts of Medical Electrical Equipment or IEC60950 1 Requirements of Information Technology equipment 4 5 6 12 IID PATTERSON MEDICAL CONTROL PANEL d D vva FF x off chs Rolyan Smart Handle Pro 1 POWER Press and hold the button to power on and off Mode Setting F 0 Peak Resistance F 1 Target Resistance F 2 Repetition Resistance 2 MENU F 3 Combo Target Rep F 4 Bluetooth Setting F 5 Volume Control 0 1 5 F 6 Unit N Ib kg F 7 1D setting 0000 9999 Press and hold the button to set the parameters for each 3 SET RESET mode or clear previously recorded data and reset zero the transducer Send the last captured data set via Bluetooth Press and hold BLUETOOTH the Bluetooth button for 2 seconds to start the sequence for smart phone or tablet identification 5 DATA Upgrade the firmware and calibrate the transducer through DATA port if necessary CHARGE Charge the battery the CHARGE indicator is lit when charge is activated through the USB charging cable or DC charger 7 uP DOwN Press to select up down the MODE and Parameters 13 LCD DISPLAY CON IID PATTERSON MEDICAL PEAK TARGET REP wi PEAK TARGET REP TARGET REP kg Battery Indicator PEAK Display in real time and peak force TARGET Target force setting REP Repetition Setting TARGET REP Target force Repetition Settings Bluetooth Indicator St
Download Pdf Manuals