OASIS® Watercooler Service Training Manual

image

Contents

1. Visually check for loose disconnected incorrectly connected or broken or frayed wires Visually check terminals for rust and corrosion To test a wire for continuity follow the steps listed below Remove the wire from all terminals so you are testing only the wire and not a circuit through any other part of the cooler 2 With your volt ohm meter in ohms mode place one meter test lead on each end of the wire If there is no reading the wire is defective and must be replaced 3 If the wire tests defective replace the entire wire Repair Solution l Replace any defective wires terminals or connectors Use appropriate size wires and connectors 2 Be sure all connections are clean and tight 3 When making a connection to a painted surface such as a painted panel check for contact and continuity 4 When finished with the repair verify the location of all wires with the electrical diagram in the Service Instructions for the cooler you are repairing 5 18 OASIS Corporation Basic Refrigeration Cycle Basic Refrigeration Cycle The refrigeration cycle removes heat from one location and disposes of the heat in another location it transfers heat The cycle takes place within a sealed system A sealed system has two advantages The same refrigerant can be used over and over again A sealed system keeps out contaminants Components of a Basic Refrigeration System The basic refrigeration system see figure
2. 3 Live from Compressor Relay to Cold Control Black 4 Live from Cold Control to Compressor Relay Black 5 Live from Compressor Relay to Hot Switch Red 6 Live from Hot Control to Compressor Relay White ircuit Diagram Electrical C Q oj 4 5 Q oj xa OTEOAI LATNI AAMOd HOLIMS ddO NO AALINIT 00109 LIV 9 LINN 3000 4109 SANIT XOV1E LINN LOH 4109 SANIT ANV AAA TOHLNOS SOSSHHdWOO HHIVHH TOHLNOO ANVIL LOH LOH Air Filter Figure 8A Assembly WaterGuard III Assembly Funnel Funnel Gasket 66 O Ring Ring Adaptor Seal Ring Gasket Check Valve Washer Float Body Check Valve Cap Probe and Tube Assembly Figure 8B WaterGuard IV Assembly Filter Check Valve Assembly Body Assembly Figure 9 Basic Refrigeration System Evaporator Lines Cooling Probe ji I Condenser T Discharge line Suction Line eue 1 LS
3. Move any other heat generating appliance away from the cooler Faucets and gaskets The faucets control the flow of water from the cooler They are located on the outside front of the cooler Check Are the faucets screwed in tightly Are the faucet threads stripped e Are the gaskets worn cracked or broken Is water dripping from around the faucets Test 1 Remove faucets 2 Inspect faucets threads and gaskets Repair Solution If defects are found then replace the relevant faucet or gasket being careful not to over tighten the faucet Do not use Teflon tape on the faucet threads Hot Tank Assembly and its Component The hot tank holds water as it is being heated and stores it until it is released through the hot faucet There are four different hot tank assemblies that have been used on Removable Reservoir Coolers Refer to figure 3 to identify the type of hot tank that is installed in your cooler Fig Type of Hot Control Type of Heat Limiter Where Used Resettable button BIRR BISR 3b One piece stainless Adjustable temperature gas Resettable button BIRR BISR filled Two piece stainless Adjustable temperature oil filled Non resettable thermal link BIRR BISR 5 4 OASIS Corporation Testing amp Repairing Cooler Parts Adjustable temperature oil filled Non resettable thermal link BIRCT A OnePiece Stainless Steel Hot Tank with Fixed Temperature Control amp Resettable Limiter Heat Limiter Th
4. pmi e Q Cold Control Condenser 4 4 Figure Hot Tank Fixed Temperature Hot Control Tank Assy HTG Thermostar Hot white dot Lead Wire Assy Green Tubing Bev a line Black Figure 3B HT1 Hot Tank Adjustable Hot Control Tank F aedi HTG SS Tie Plastic Wire Control Heating ECS CCR Heat Insulation Limiter m CF Hot Tank _ LT Lead Wire Clip Assy Green Thermostat Tubing Bev a line Black Valve Assy Drain Figure 3C HT2 Hot Tank Floor Standing Cooler Hot Tank Body amp Head Assembly Thermostat Over Temp Device Terminated Drain Tubing Drain Valve Assy Assembled View Exploded View Figure 3D HT2 Hot Tank Countertop Cooler Over Temp Device Terminated ET Drain Tubing 8 Drain Valve Assy Heater Pan Assembly Assembled View Exploded View Figure 4 Hot Tank Vent Hole Hot Tank Fill Tube Vent Hole Outlet Tube to Hot Faucet Hot Tank Drainage Tube Condenser Compressor Relay gt m e ER e un un d ER E Q lt e a 2 5 Compressor Figure 6A Starting Relay Cold Neutral to IEC Inlet White 2 Live from IEC Inlet Black 3 Live from Compressor Relay to Cold Control Black 4 Live from Cold Control to Compressor Relay Black Figure 6B Starting Relay Hot Neutral to IEC Inlet White 2 Live from IEC Inlet Black
5. Removable reservoir Removable reservoir Location of the cold control Hot tank Fixed temperature hot control 1 Hot tank Adjustable hot control HT2 Hot tank Floor Standing Cooler HT2 Hot tank Countertop Cooler Hot tank vent hole Location of compressor relay Start relay cold Start relay hot Electrical circuit diagrams WaterGuard III assembly WaterGuard IV assembly Basic refrigeration system OASIS Corporation Introduction Chapter 1 Introduction OASIS Manufacturing Company founded in 1910 in Columbus Ohio as the D A Ebinger Sanitary Manufacturing Company manufactures water coolers for distribution world wide OASIS products including the OASIS brand coolers are supported by more than 400 authorised service centres OASIS quality is a result of rigid standards for raw materials precision tooling efficient manufacturing methods and extensive testing of all subassemblies and completed units OASIS s distributors maintain a high level of customer service This manual is intended for use in OASIS service training and for reference It presents aids to troubleshooting problems testing and repair instructions and basic information about refrigeration cycles Diagrams and schematics of standard models of OASIS coolers are provided as examples The primary emphasis of this manual is the Removable Reservoir range of bottle water coolers Although the function of the compressor and possible sympt
6. That all the wires and electrical connections are in place at the back of the cooler e Thatthe cold control is set to the maximum cold position f Thatthe hot tank switch is in the OFF position g Thatthe cooler is clean and dust free OASIS Corporation General Care of the Removable Reservoir Cooler 5 Sanitise the water cooler 6 Replace the shipping bag over the water cooler 7 Replace the carton over the top of the cooler 8 cooler is now ready for transportation to the customer s premises Installing the water cooler at your customer s premises 1 Carry the cooler in the upright position to the customer s premises use the handle at the rear of the unit DO NOT LIFT THE UNIT BY THE FAUCETS 2 Atthe customer s premises ensure that there are no marks or visible damage to the carton 3 Remove the cooler from the carton 4 Remove the shipping bag from the cooler 5 Carry out a general inspection of the cooler ensuring that a There are no marks or physical damage to the cooler b That all accessories are present c Thatthe faucets are tight and in an upright position d Thatall the wires and electrical connections are in place at the back of the cooler e Thatthe cold control is set to the maximum cold position f That the hot tank switch is in the OFF position g Thatthe cooler is clean and dust free 6 Place a bottle of water on top of the unit As soon as the bottle is in place ens
7. 2 Check hot faucet 55 3 Check for mineral build up in hot tank 4 2 3 2 OASIS Corporation Symptom Hot water too hot or boiling over Water leaks Oil on refrigerant lines Troubleshooting Troubleshooting Chart for Bottle Coolers continued Solution Checklist Has tank been bled of air Check hot control Check for mineral build up in hot tank Check for plugged hot tank vent hole pou 1 Check for cracked plastic bottle 2 Check for damaged reservoir 3 Check for loose faucet or damaged gasket 4 Check hot tank inlet seal 5 Check hot faucet fitting 6 Check hot tank drain fittings 7 Check hot tank for damage Unplug service cord Contact refrigeration repairman N 3 3 Page 2 2 5 5 4 2 5 17 5 21 5 19 5 5 5 5 3 5 5 5 5 5 OASIS Corporation Easy Solutions Chapter 4 Easy Solutions Some problems have simple solutions This chapter describes three cases in which a cooler is not meeting a customer s needs but nothing is wrong with the cooler In the first case the cooler is not receiving the correct voltage In the second case the capacity of the cooler is inadequate for the customer s requirements and in the third case the cooler simply needs to be cleaned Checking the Voltage Received By the Cooler The easiest solution to a non working cooler may be to plug the cooler s service cord into an electrical outlet Although most solutions are not usually this simple to find do not
8. 9 contains five components Refrigerant Metering device in figure 9 the capillary tube Evaporator Compressor Condenser Refrigerant carries the heat being transferred The four other components of the refrigerant cycle the metering device the evaporator the compressor and the condenser are parts of the mechanical cycle The metering device can be an expansion valve or capillary tube In the mechanical cycle it is placed before the evaporator Refrigerant changes from a liquid to a gas in the evaporator The compressor or pump serves two functions It compresses the low pressure low temperature gas into a high pressure high temperature gas and it keeps the refrigerant flowing through the cycle In the condenser the high pressure high temperature refrigerant gas condenses to a liquid OASIS Corporation Basic Refrigeration Cycle How the Components Work Together to Form a Refrigeration Cycle The principle underlying the design of all refrigeration cycled is that liquid extracts heat from its immediate surroundings when it evaporates to a gas In the water cooler the liquid is the refrigerant In the evaporator the refrigerant changes from a liquid to a gas This change instate occurs due to the following conditions The refrigerant coming out of the metering device a capillary tube in all Removable Reservoir coolers is a high pressure liquid As this liquid flows into the large tubing of the evaporat
9. Test 1 Visually inspect the hot tank If holes or cracks are discovered replace the tank 2 Test for a short between the heat element coil and the hot tank by following the steps listed below 3 Unplug the cooler 4 Place one meter test lead on one of the heat element terminals 5 Place the other meter test lead on the tank 6 If there is a reading there is a short circuit between the heating element and the tank and the element or tank must be replaced Repair Solution If mineral build up is evident clean the hot tank following the procedure listed in Chapter 4 Cleaning the Bottle Cooler Hot Tank 5 8 OASIS Corporation Testing amp Repairing Cooler Parts CAUTION Extreme care must be exercised in rinsing the tank to remove all acid or chemical cleaners Be sure to open the hot tank drain and to rinse the drain line as well as the tank Test the tank water with litmus paper before reusing the tank To remove and replace the hot tank follow the steps listed below Drain the hot tank through the drain valve assembly Remove the cooler chassis from the cabinet see pg 5 1 Disconnect the earth wire from the cooler base Disconnect the red fused lead wire from the heat limiter Disconnect the white neutral lead wire from the thermostat Remove the two screws attaching the drain valve assembly to the condenser Remove the two screws attaching the hot tank to the shelf and lift out the hot tank assembly Pull the n
10. be lulled into forgetting to check this possible cause of trouble Check Is the service cord plugged in Is the switch controlling the outlet in the OFF position Test 1 Plug in the cooler 2 Make sure any switch controlling the outlet is in the ON position Remove the service cord from the wall outlet and plug in a portable radio or similar device If the radio works the outlet is good Repair Solution Incorrect voltage through the outlet may need to be corrected by the local utility company Contacting the utility is the responsibility of the customer Matching the Customer s Needs with the Cooler s Capacity Under normal conditions most bottle coolers will produce 4 5 litres of cold water lt 10 per hour and a little more than nine litres of hot water 80 90 per hour Check Room temperature If the temperature of the room containing the cooler or the temperature of the water in the cooler s water bottle is above 32 the cooler will not be able to provide as much cold water within the standard amount of time Amount of hot cold water required in an average hour Find out how many persons use the cooler each hour and what size cups they are filling Calculate the total amount of water required in an average hour Special customer needs for large amounts of water during certain periods of the day For example does the customer need nine litres of cold water at 12 45 each afternoon to fill
11. body of the control to the mounting bracket Connect the positive and neutral wires Hot Tank The hot tank hold water as it is being heated and stores it until it is released through the hot faucet 5 12 OASIS Corporation Testing amp Repairing Cooler Parts Check Is the heater element coil of the hot tank defective Is there a short between the heater element coil and the hot tank Do you see holes or cracks in the tank e Do you see evidence of mineral build up in the tank Test 1 Visually inspect the hot tank If holes or cracks are discovered replace the tank 2 Test for a short between the heat element coil and the hot tank by following the steps listed below 3 Unplug the cooler 4 Place one meter test lead on one of the heat element terminals 5 Place the other meter test lead on the tank 6 If there is a reading there is a short circuit between the heating element and the tank and the element or tank must be replaced Repair Solution If mineral build up is evident clean the hot tank following the procedure listed in Chapter 4 Cleaning the Bottle Cooler Hot Tank CAUTION Extreme care must be exercised in rinsing the tank to remove all acid or chemical cleaners Be sure to open the hot tank drain and to rinse the drain line as well as the tank Test the tank water with litmus paper before reusing the tank To remove and replace the hot tank follow the steps listed below Drain the h
12. heat limiter 5 Place one meter test lead on each terminal of the heat limiter 6 There should be a reading continuity should exist Try to reset the limiter If continuity still does not exist replace the heat limiter Repair Solution A defective heat limiter is replaced not repaired To replace the heat limiter complete the following steps 1 Remove the heat limiter wires 2 Remove the screws holding the heat limiter to the hot tank bracket 3 Screw the new heat limiter to the hot tank and connect the positive and neutral wires Hot Control The hot control determines the temperature of the water in the hot tank Check e Are the terminals of the hot control bent or broken 5 7 OASIS Corporation Testing amp Repairing Cooler Parts e Are the wires of the hot control loose Does the hot control appear to be broken e Is the hot control in firm contact with the hot tank Check for continuity Test Inspect the control and test for continuity by following the steps listed below Unplug the service cord Visually inspect the control See if the terminals are bent or broken or the wires are loose Check that the sensing part of the control is tightly inserted into the relevant tube in the hot tank Set your volt ohm meter to ohms mode Remove both positive and neutral wires from the control Place one meter test lead on each terminal of the hot control There should be a reading continuity should exis
13. lead on the tank 6 If there is a reading there is a short circuit between the heating element and the tank and the element or tank must be replaced Repair Solution If mineral build up is evident clean the hot tank following the procedure listed in Chapter 4 Cleaning the Bottle Cooler Hot Tank CAUTION Extreme care must be exercised in rinsing the tank to remove all acid or chemical cleaners Be sure to open the hot tank drain and to rinse the drain line as well as the tank Test the tank water with litmus paper before reusing the tank To remove and replace the hot tank follow the steps listed below 1 Drain the hot tank through the drain valve assembly 2 Remove the cooler chassis from the cabinet see pg 5 1 9 Disconnect the earth wire from the cooler base 4 Disconnect the red fused lead wire from the heat limiter 5 6 OASIS Corporation Testing amp Repairing Cooler Parts 5 Disconnect the white neutral lead wire from the thermostat 6 Remove the two screws attaching the drain valve assembly to the condenser 7 Remove the two screws attaching the hot tank to the shelf and lift out the hot tank assembly 8 Pull the new hot tank up into position under the shelf 9 TIP Attach the earth wire to the hot tank before installation 10 Attach the tank to the shelf with two screws 11 new hot control and heat limiter are provided with the replacement tank 12 Attach wires to heat limiter and hot control Refer
14. the old cold control Gently pull the capillary tube out of the capillary well Carefully straighten the capillary tube over the new control Do not kink or break the capillary tube Place the old and new controls and capillary tubes side by side with the sensing ends of the controls next to each other 7 Transfer the masking tape from the old capillary tube to the new one Using this method will enable you to insert the new capillary the same distance into the capillary well as the old tube 8 Gently insert the new capillary tube into the capillary well until the masking tape is at the end of the well If necessary lubricate the tube with a small amount of oil before inserting it into the well 9 Attach the new cold control to the condenser with the two mounting screws being careful to keep the capillary tube away from the condenser and hot tank when cooler is equipped with a hot tank 10 Attach the wires to the terminals Be sure not to attach power wires to ground terminals 11 Turn the adjusting screw to the MAX cold position 12 Check the operation of the cooler D Compressor The compressor see figure 9 or pump serves two functions It compresses the low pressure low temperature gas into a high pressure high temperature gas and it keeps the refrigerant flowing through the cycle CAUTION Under no circumstances are you to attempt to replace or repair the compressor The refrigeration system includin
15. to the electrical diagram on the back page of the Service Instruction for the cooler you are repairing This schematic is also displayed on the inside of the cooler 13 Refitthe drain valve assembly to the condenser 14 Check for water leaks B One Piece Stainless Steel Hot Tank with Adjustable Temperature Control amp Resettable Limiter Heat Limiter The heat limiter prevents dangerous overheating of the cooler The resettable heat limiter consists of a bi metal disk that bends when heated above 90 breaking electrical contact When the heat limiter cools to approximately 45 C manually push the reset button and the limiter will work again CAUTION Use of the heat limiter is an Underwriters Laboratory requirement Any attempt to bypass this part will result in the loss of warranty coverage Check Check for continuity Are the terminals of the heat limiter bent or broken Are the wires of the heat limiter loose Note Operating the cooler when the hot tank is not completely full of water with all air bled off will cause the heat limiter to break electrical contact When this occurs push the reset button Test Inspect the heat limiter and test for continuity by following the steps listed below l Unplug the service cord 2 Visually inspect the heat limiter See if the terminals are bent or broken or the wires are loose 3 Set your volt ohm meter to ohms mode 4 Remove both positive and neutral wires from the
16. 82002 032582002 032582002 032582002 Handie 029562001 029562001 029562001 029562 001 Stot 5 031374001 031374001 031374001 031374001 O Ring Reservoir Probe 030858310 030858310 030858310 030858310 Retainer O Ring 032278001 032278001 032278001 03227800 O Ring Reservoir Hot 030858212 030858212 Limiter Heat 032731002 032731 002 Clamp Tube 026516 026516 NA Tube Drain 028715008 028715008 Insulation Hot Tank 03273400 032734001 Cover Compressor 026295 026295 026295 026295 Cord PowerSupply Euro 030401011 0304014011 030401011 030401011 _ Cord Power Supply UK 030401010 0304014010 030401 010 030401010 7 FEL CCC CF CF E SIF LIT III SIF SAS SF LE 2 7 n CLIZILL TIR LOL LIL LOL LOL 227 LOL 227 227 LOT LIT LIL IR LLLA gt N A4 Figure 1B Removable Reservoir er SSEL FA A PFA P 222222 SS S gt lt lt lt gt ss 2277722222272 22 LLL 222 217 LLL LLL AEL LLL LIL LLL LLL LLL LLL LLL LIL 02222022 02220222 LLL LLL LLL LIL LLL LLL LIL LIL LIL LIL L LL L LIL LL L LLZ A 12222222 GS Cabinet Insulation nl Q 92 9 Oh S om
17. OASIS Watercooler Service Training Manual Chapter 1 Chapter 2 Chapter 3 Chapter 4 Chapter 5 Appendix Appendix B Contents Introduction General Care of the Removable Reservoir Cooler Caring for your water cooler Sanitising your water cooler Setting up the water cooler at your premises Installing the water cooler at your customer s premises Troubleshooting Easy Solutions Checking the Voltage Received by the Cooler Matching the Customer s Needs with the Cooler s Capacity Cleaning the Bottle Cooler s Hot Tank Testing and Repairing Cooler Parts Safety Precautions Access to Parts Inside the Cooler Airbell Baffle Capillary Line and Strainer Cold Control Compressor Condenser Faucets and Gaskets Hot Tank and its Components Hot Tank Switch Hot Tank Vent Hole Overload Refrigerant Relays Removable Reservoir Service Cord Tubing Water Bottle WaterGuard Wires Terminals and Connectors Basic Refrigeration Cycle Components of a Basic Refrigeration System How the Components Work Together to Form a Refrigeration Cycle Exploded Parts Breakdown of OASIS Bottle Coolers 11 2 1 2 1 2 1 22 23 3 1 4 1 4 1 4 1 4 2 5 1 5 1 5 1 5 2 5 2 5 2 5 3 54 54 54 5 14 5 14 5 14 5 14 5 14 5 15 5 15 5 16 5 16 5 17 5 17 A 1 A2 B 1 Diagrams Fig 1 Fig 1B Fig2 Fig 3A Fig 3B Fig 3C Fig 3D Fig4 Fig 5 Fig 6A Fig 6B Fig 7 Fig 8A Fig 8B Fig9
18. S Corporation Testing amp Repairing Cooler Parts Test Visually inspect the reservoir If holes or cracks are discovered replace the reservoir Visually inspect all threaded holes for damage If the threads are damaged replace the reservoir Repair Solution If mineral build up is evident sanitise the reservoir as described in Chapter 2 Sanitising your Water Cooler Service Cord The service cord power cord extends from the compressor to the power source in the room The service cord contains three wires CAUTION Never cut off the ground pin the third leg on the plug If the available outlet will accept only a 2 pronged plug then a properly grounded adapter must be used This is an important safety feature do not eliminate it Check Are any of the three wires broken Are any of the three terminals broken Is the cord insulation frayed cut or damaged in any other way Check for continuity Test Visually check for broken wires and terminals and damaged insulation Test for continuity by following the steps below 1 Unplug the service cord 2 Remove the service cord from the holder 3 There are three wires to be tested With your volt ohm meter in ohms mode place one meter test lead on the end of one wire Place the other test lead on one terminal at the other end of the cord and check the meter 4 With the first lead still on the first wire move the second test lead to the second terminal an
19. a bottle in place When properly installed the water cooler is electrically safe Even so do not locate the cooler in constantly damp areas beneath dripping pipes or where water may collect underfoot Keep areas around the water cooler free from dirt and rubbish The plastic cabinetry should be cleaned using mild soap and water Do NOT use bleach or any cleaning agents containing bleach or chlorine Sanitising your Water Cooler Recommended Materials Disposable gloves One time use wipes Mild cleaning agent for outside of cabinet and drip receptor The following cleaners are acceptable Mild soap and water Fairy Liquid Fantastik DO NOT use bleach or any cleaning agents containing bleach or chlorine Chlorine test kit OASIS Corporation General Care of the Removable Reservoir Cooler Sanitisation Procedure 1 Disconnect the power supply from the cooler 2 Remove the bottle from the reservoir 3 Drain water from the reservoir and hot tank if fitted through the faucets 4 Remove the WaterGuard 5 Remove the faucets 6 Disassemble the WaterGuard and discard the air filter 7 Remove the baffle 8 Remove the reservoir 9 Wash hands thoroughly 10 Put on disposable gloves 11 Wash the faucets WaterGuard components baffle and reservoir using mild soap and water 12 Rinse with clean water immediately 13 Clean the faucets WaterGuard components baffle and reservoir using the sanitising solution Parts MUST be completely s
20. assis from the cabinet The steps below outline the procedure for all removable reservoir coolers To replace the chassis inside the cabinet reverse the instructions 1 Drain the water from the cooler e Remove the bottle from the reservoir e Drain water through the faucets 2 Remove the reservoir e Liftoff WaterGuard assembly if fitted e Remove faucets and faucet gaskets e Grasp the top of the reservoir around the opening and pull upwards in a straight motion 3 Remove the cooler chassis from the cabinet A Floor Standing Coolers e Remove the two screws attaching the metal shelf of the cooler to the cabinet e Remove the two screws attaching the metal base of the cooler to the cabinet e cooler chassis from the cabinet B Countertop Coolers e Remove the drip tray e Unsnap the drain plug from the base Hot model only e the cooler on its side and pull off the base it is simply snapped into position e Remove the 4 screws fixing the cabinet to the metal base of the cooler 5 1 OASIS Corporation Testing amp Repairing Cooler Parts e Liftthe cabinet from the cooler chassis Airbell Baffle The airbell baffle shown in Figure 1 controls the flow of water inside the cooling reservoir It disperses incoming water evenly around the probe at the bottom of the reservoir When the cold faucet is opened the baffle ensures that the water flows out of the tank from the area near the probe not straight down through th
21. at protects the compressor by turning the cooler off when the compressor has overheated All compressors used on removable reservoir water have internal overloads that are inaccessible It 18 not possible to replace a faulty overload you must replace the compressor assembly Refrigerant The refrigerant is the substance that carries heat throughout the refrigeration cycle The refrigeration absorbs and disposes of heat depending upon different pressures applied to the refrigerant causing evaporation and condensation On the low side of the cycle the refrigerant evaporates and collects heat On the high side a pump submits the refrigerant to high pressure causing the refrigerant to condense to a liquid and dispose of the heat 5 14 OASIS Corporation Testing amp Repairing Cooler Parts Check Is refrigerant leaking Repair Solution Refer this problem to a qualified refrigeration repairman CAUTION Under no circumstances are you to attempt to replace or repair the compressor The refrigeration system including all refrigerant lines may be serviced only by a fully certified refrigeration repairman Relays A starting relay see figure 6 is used to start the compressor The starting relay is located on the outside of the compressor in the compressor relay box see figure 5 Figure 7 shows the location of the ceramic PTC relay within the electrical systems of the Danfoss compressor Check Check the continuity of the sta
22. ater element coil of the hot tank defective Is there short between the heater element coil and the hot tank Do you see holes or cracks in the tank Do you see evidence of mineral build up in the tank Test 1 Visually inspect the hot tank If holes or cracks are discovered replace the tank 2 Test for a short between the heat element coil and the hot tank by following the steps listed below 3 Unplug the cooler 5 10 OASIS Corporation Testing amp Repairing Cooler Parts 4 Place one meter test lead on one of the heat element terminals 5 Place the other meter test lead on the tank 6 If there is a reading there is a short circuit between the heating element and the tank and the element or tank must be replaced Repair Solution If mineral build up is evident clean the hot tank following the procedure listed in Chapter 4 Cleaning the Bottle Cooler Hot Tank CAUTION Extreme care must be exercised in rinsing the tank to remove all acid or chemical cleaners Be sure to open the hot tank drain and to rinse the drain line as well as the tank Test the tank water with litmus paper before reusing the tank To remove and replace the hot tank follow the steps listed below Drain the hot tank through the drain valve assembly Remove the cooler chassis from the cabinet see pg 5 1 Disconnect the earth wire from the cooler base Disconnect the red fused lead wire from the heat limiter Disconnect the whit
23. continuity by following the steps listed below 1 Unplug the service cord 2 Visually inspect the heat limiter See if the terminals are bent or broken or the wires are loose 3 Set your volt ohm meter to ohms mode 4 Remove both positive and neutral wires from the heat limiter 5 Place one meter test lead on each terminal of the heat limiter 6 There should be a reading continuity should exist Repair Solution A defective heat limiter is replaced not repaired To replace the heat limiter complete the following steps 1 Remove the heat limiter wires 2 Remove the P clamp 5 9 OASIS Corporation Testing amp Repairing Cooler Parts 3 Remove the heat limiter from its location tube in the base of the hot tank 4 Insert the new heat limiter and reconnect the positive and neutral wires and the P clamp Hot Control The hot control determines the temperature of the water in the hot tank Check Are the terminals of the hot control bent or broken e Are the wires of the hot control loose Does the hot control appear to be broken Is the hot control in firm contact with the hot tank e Check for continuity Test Inspect the control and test for continuity by following the steps listed below Unplug the service cord Visually inspect the control See if the terminals are bent or broken or the wires are loose Check that the sensing part of the control is tightly inserted into the relevant tube in the h
24. d check the meter 5 With the first lead still on the first wire move the second test lead to the third terminal and check the meter 6 The meter should indicate continuity there should be a reading at only one terminal If continuity exists for more than one terminal there is a short in the tested wire and the service cord must be replaced 7 Test each of the other two wires in the same manner Repair Solution Replace the service cord if it is defective or if its insulation is damaged Tubing Tubing refers to the discharge line the capillary tube and the liquid line Tubing that comes into contact with other parts of the cooler may cause a vibration Check Is a section of the line vibrating against another cooler part 5 16 OASIS Corporation Testing amp Repairing Cooler Parts Repair Solution Eliminate vibrations by moving tubing away from other cooler parts CAUTION Do not break tubing when moving it Water Bottle The water bottle holds the water being supplied to the cooler It sits upside down on top of the cooler Most water bottles in use today are made of plastic Check Are cracks visible Repair Solution 1 Unplug the cooler 2 Using a towel remove any water that has leaked into the cooler 3 Put a new bottle of water in place Note cracked water bottle will overflow the reservoir and spill water into the unit and onto the floor WaterGuard The WaterGuard see figure 8 protects
25. e heat limiter prevents dangerous overheating of the cooler The resetable heat limiter consists of a bi metal disk that bends when heated above 90 breaking electrical contact When the heat limiter cools to approximately 45 C manually push the reset button and the limiter will work again CAUTION Use of the heat limiter is an Underwriters Laboratory requirement Any attempt to bypass this part will result in the loss of warranty coverage Check Check for continuity Are the terminals of the heat limiter bent or broken Are the wires of the heat limiter loose Note Operating the cooler when the hot tank is not completely full of water with all air bled off will cause the heat limiter to break electrical contact When this occurs push the reset button Test Inspect the heat limiter and test for continuity by following the steps listed below 1 Unplug the service cord 2 Visually inspect the heat limiter See if the terminals are bent or broken or the wires are loose 3 Set your volt ohm meter to ohms mode 4 Remove both positive and neutral wires from the heat limiter 5 Place one meter test lead on each terminal of the heat limiter 6 There should be a reading continuity should exist Try to reset the limiter If continuity still does not exist replace the heat limiter Repair Solution A defective heat limiter is replaced not repaired To replace the heat limiter complete the following steps 1 Remove
26. e neutral lead wire from the hot control Remove the two screws attaching the drain valve assembly to the condenser Remove the two screws attaching the hot tank to the shelf and lift out the hot tank assembly Pull the new hot tank up into position under the shelf TIP Attach the earth wire to the hot tank before installation Attach the tank to the shelf with two screws A new hot control and heat limiter are provided with the replacement tank Attach wires to heat limiter and hot control Refer to the electrical diagram on the back page of the Service Instruction for the cooler you are repairing This schematic is also displayed on the inside of the cooler Refit the drain valve assembly to the condenser Check for water leaks ee B D Two Piece Stainless Steel Hot Tank with Adjustable Temperature Control amp Non resettable Limiter Countertop Coolers Heat Limiter The heat limiter used is a thermal link which breaks if the temperature of the hot tank exceeds a set limit It is a single use device if it operates it needs to be replaced before the hot tank can be used CAUTION Use of the heat limiter is an Underwriters Laboratory requirement Any attempt to bypass this part will result in the loss of warranty coverage Check Check for continuity Are the terminals of the heat limiter bent or broken Are the wires of the heat limiter loose Note Operating the coole
27. e reservoir which would result in a flow of room temperature water The baffle is located inside the cooling reservoir The baffle tube should sit securely on the moulded fitting in the reservoir Check e Has the baffle been removed from the cooler Is the baffle in the correct place Does the tube on the baffle fit tightly onto the moulded fitting in the reservoir Test To test the tightness of the baffle tube in the reservoir fitting gently pull up on the baffle Repair Solution If the baffle does not fit tightly into the reservoir replace the baffle Capillary Line and Strainer The capillary line tube and strainer see figure 9 measure the amount of refrigerant released to the evaporator They appear in the refrigeration cycle just before the evaporator coils If the capillary line or strainer is restricted the proper flow of refrigerant will be disturbed and the water will not be adequately cooled Check Visually check to see that lines are not bent Repair Solution Refer the repair of a broken or damaged capillary line or strainer to a refrigeration repairman Cold Control The cold control see figure 2 enables you to adjust the temperature to which the water is cooled On all Removable Reservoir coolers the cold control is attached to the condenser Check Check for continuity Is the control set too low or set to OFF Are the terminals of the control bent or broken Is the capillary
28. ew hot tank up into position under the shelf TIP Attach the earth wire to the hot tank before installation Attach the tank to the shelf with two screws A new hot control and heat limiter are provided with the replacement tank Attach wires to heat limiter and hot control Refer to the electrical diagram on the back page of the Service Instruction for the cooler you are repairing This schematic is also displayed on the inside of the cooler Refit the drain valve assembly to the condenser Check for water leaks PE en gt B C Two Piece Stainless Steel Hot Tank with Adjustable Temperature Control amp Non resettable Limiter Floor Standing Coolers Heat Limiter The heat limiter used is a thermal link which breaks if the temperature of the hot tank exceeds a set limit It is a single use device if it operates it needs to be replaced before the hot tank can be used CAUTION Use of the heat limiter is an Underwriters Laboratory requirement Any attempt to bypass this part will result in the loss of warranty coverage Check Check for continuity Are the terminals of the heat limiter bent or broken Are the wires of the heat limiter loose Note Operating the cooler when the hot tank is not completely full of water with all air bled off will cause the heat limiter to break electrical contact When this occurs the heat limiter must be replaced Test Inspect the heat limiter and test for
29. g all refrigerant lines may be serviced only by a fully certified refrigerant repairman Only original equipment replacement parts provided by OASIS Manufacturing Company should be used for OASIS water coolers CAUTION Whenever you suspect problems with the compressor immediately unplug the cooler This action may prevent serious damage to the compressor or the refrigeration system Check Immediately unplug the cooler and refer the repair to a refrigeration repairman in any of the following cases The compressor runs but does not cool the water The unit may be low on refrigerant 5 3 OASIS Corporation Testing amp Repairing Cooler Parts The compressor runs short time and shuts off then repeats pattern several times The refrigerant lines may be restricted The compressor runs and will not shut off Refrigerant oil is visible on a refrigerant line Condenser The condenser See figure 9 receives hot pressurised refrigerant gas from the compressor and cools it until the gas changes to a liquid state In doing so the condenser transfers heat from the refrigerant into the air surrounding the condenser coils Check Is the condenser clean Is the cooler so close to the wall that it restricts air flow around the condenser coils Is the cooler near any other heat source Repair Solution 1 Remove any dirt or grease from the cooler 2 Leave at least two inches between the cooler and the wall
30. mm from the top To allow the hot tank to fill open the hot faucet until the water begins to flow then close the faucet Plug the service cord into the wall socket Let the unit stand for at least twenty minutes While the citric acid solution is cleaning the hot tank this is a good time to clean the rest of the unit Inspect the back of the unit for lint or dirt on the wire and tube condenser If it is dirty clean it with a non wire stiff brush or a vacuum cleaner Unplug the service cord Using rubber gloves and taking care not to scald your hands draw water from the hot faucet until the flow ceases Open the heating tank drain catching the water in a pan or bucket The water will be discoloured This drain water should be immediately poured down a drain to prevent accidental spilling this water will stain Pour at least 4 5 litres of bottled water into the cooling reservoir and allow this water to drain from the heating tank drain Drain any remaining water in the reservoir through the cold faucet Turn the drain valve to a closed position when the hot tank is empty Replace the baffle and place a bottle of water on the unit Open the hot faucet to allow the tank to fill Plug the service cord back into the wall socket After the unit has run for ten to fifteen minutes draw at least one litre of water from both hot and cold faucets Your heating tank should now be clean If the flow of water or the noisy cycles have not been improved y
31. nt or broken or the wires are loose 3 Set your volt ohm meter to ohms mode 4 Remove both positive and neutral wires from the switch 5 Place one meter test lead to each switch terminal The switch must be in the on position the end of the switch marked must be depressed 6 There should be a reading continuity should exist If this is not the case replace the hot tank paddle switch Repair Solution A defective hot tank switch is replaced not repaired To install a new switch depress the side tabs and lift out then simply press a new switch into place and attach the positive and neutral wires Hot Tank Vent Hole The hot tank vent hole See figure 4 provides an outlet for steam which is produced if the water in the hot tank boils Check Uneven flow of water from the hot faucet Test 1 Allow the hot tank to cycle until it reaches full hot temperature 2 Open the hot faucet 3 If a few drops of water come out of the faucet followed by no water at all followed by water flowing freely the hot tank vent hole may be plugged by mineral deposits or other foreign matter Repair Solution To clean the hot tank vent hole follow the steps below 1 Clean the hot tank follow the instructions 2 Run a small diameter non metallic wire brush through the hot tank fill tube 3 To remove mineral deposits from the vent hole work the brush up and down while turning it Overload The overload is a switch th
32. oms indicating the need for its replacement are discussed in this manual no compressor replacement instructions are included inside Replacement of compressors must be handled by a fully qualified refrigeration repairman If you are unfamiliar with how a bast refrigeration cycle works or with standard OASIS bottle coolers begin by referring to the following appendices A Basic Refrigeration Cycle B Exploded Parts Breakdown of OASIS Bottle Cooler 1 1 OASIS Corporation General Care of the Removable Reservoir Cooler Chapter 2 General Care of the Removable Reservoir Cooler D 99 n QN Cn dO gt N ES a m P tA Caring for your water cooler Do not locate your cooler where the environment would offer any risk of water contamination The cooler must be located on a floor which is smooth level and easily cleaned Do not locate the cooler in direct sunlight Do not locate the cooler next to a radiator Do not locate the cooler within or directly adjacent to toilet facilities Do not use the cooler or water bottle as a shelf for plants or objects Do not use sprays mists or vapours around the water cooler Do not put any other liquid other than water into the cooler Do not touch the nozzles of the faucets Do not take water from the faucets if your hands are dirty Do not lay the cooler on its side Do not leave the cooler without a bottle fitted Do not attempt to move the cooler if there is
33. or it finds room to expand As the liquid expands both the pressure and the temperature drop and the refrigerant changes to a low pressure low temperature gas This low temperature gas absorbs heat from the reservoir and the water init The heat carrying gas is then carried into the compressor through the suction line In the compressor the low pressure low temperature gas is compressed into a high pressure high temperature gas The high pressure high temperature gas is pumped from the compressor to the condenser through the discharge line In the condenser the high pressure high temperature refrigerant gas condenses to a liquid This change in state occurs due to the following conditions The temperature of the refrigerant is higher than the temperature of the condenser coils and the air surrounding them The heat from the refrigerant is absorbed by the condenser coils and dissipates into the air The refrigerant still in a high pressure liquid state 15 forced into the metering device through the liquid line and the refrigeration cycle begins again Appendix 1 Exploded Parts Drawing Appendix B1 Illustrated Parts Listing DESCRIPTION B1RRHS B1SRHS B1RRK B1SRK 032510 6xx 032520 6xx 032511 5xx 032521 5xx 032511 2xx 032521 2xx 6 Insulation Reservoir 031427002 031427002 031427001 031427001 8 Shef 034006001 034006001 034006001 034006001 9 ColdControl 0325
34. ot tank Set your volt ohm meter to ohms mode Remove both positive and neutral wires from the control Place one meter test lead on each terminal of the hot control There should be a reading continuity should exist If this is not the case replace the hot control If no problems are discovered through the steps above it is possible that the hot control is miscalibrated Since checking calibration requires special equipment OASIS recommends that you simply replace the hot control with a test control that you know is correctly calibrated If the cooler then works properly replace your test control with a new hot control and save the test control for future testing Repair Solution Unless the problem is solved by simply tightening or replacing the mounting screws replace the hot control To replace the hot control complete the following steps 1 Remove the hot control wires You will have already done this if you just tested the control 2 Remove the screws holding the hot control to its mounting bracket and withdraw the sensing bulb of the control from the relevant tube in the hot tank 3 Install the sensing bulb of the new control into the tube on the hot tank and screw the body of the control to the mounting bracket Connect the positive and neutral wires Hot Tank The hot tank holds water as it is being heated and stores it until it is released through the hot faucet Check Is the he
35. ot tank through the drain valve assembly Remove the cooler chassis from the cabinet see pg 5 1 Disconnect the earth wire from the cooler base Disconnect the red fused lead wire from the heat limiter Disconnect the white neutral lead wire from the hot control Remove the two screws attaching the hot tank to the shelf Slide the stainless steel reservoir inlet fitting and the plastic hot faucet fitting from their location points on the shelf 8 Slide the hot tank forward and remove 9 Pull the new hot tank up into position under the shelf 10 Attach the earth wire to the hot tank before installation 11 Attach the tank to the shelf with two screws 12 A new hot control and heat limiter are provided with the replacement tank 13 Attach wires to heat limiter and hot control Refer to the electrical diagram on the back page of the Service Instruction for the cooler you are repairing This schematic is also displayed on the inside of the cooler 14 Check for water leaks DA gv A de p poor Hot Tank Switch The hot tank switch turns the hot tank on and off Check Are the terminals of the switch bent or broken Are the wires of the switch loose Check for continuity 5 13 OASIS Corporation Testing amp Repairing Cooler Parts Test Inspect the switch and test for continuity by following the steps listed below l Unplug the service cord 2 Visually inspect the switch See if the terminals are be
36. ou should have the unit repaired at an authorised service centre Cleaning the unit in this manner will not only make the unit run more efficiently but will make the water taste better OASIS Corporation Testing amp Repairing Cooler Parts Chapter 5 Testing and Repairing Cooler Parts Chapter 5 provides detailed instructions on how to inspect test repair and replace the OASIS cooler parts you will most frequently be required to service Use the troubleshooting chart provided in Chapter 3 to diagnose potential problems then refer to this chapter for specific information about each part mentioned in the troubleshooting chart OASIS cooler parts are organised alphabetically in this chapter Review the following safety precautions before beginning service on any cooler Safety Precautions 1l ALWAYS UNPLUG THE COOLER BEFORE WORKING ON IT The water coolers described in this manual operate on either 115 volts 60 hertz single phase or on 220 240 volts 50 60 hertz single phase Every effort should be made to avoid electric shock 2 When using a volt ohm meter in the Ohms mode be sure the cooler is unplugged 3 Whenusing volt ohm meter in the AC volts mode be sure the meter is set on a level sufficient for the voltage in use 4 Check to be sure the outlet provides the voltage required by the cooler Access to parts inside the cooler Before beginning the service inspection and or repair you will need to remove the cooler ch
37. pitchers for meeting rooms Does the customer need eighteen litres of hot water early each day when coffee or tea is prepared Repair Solution If a customer s demands are exceeding the cooler s capabilities suggest adding another cooler 4 1 OASIS Corporation Easy Solutions Cleaning the Bottle Cooler s Hot Tank The use of some types of water may eventually cause a build up of mineral deposits on the inside of the hot tank These mineral deposits insulate the water in the tank from the hot control and prevent the hot control from sensing the hot water temperature Bottle water coolers need to be cleaned periodically to prevent this mineral build up inside the heating tank The frequency of cleaning is determined by the quantity of minerals in the bottle water and the amount of water used Heating tanks may require cleaning when 1 Normal hot water flow appears restricted 2 Noisy heating cycles are heard 3 Water in the cooling tank is very warm 4 Mineral build up has imparted a taste to the water Offer your customers hot tank cleaning whenever a cooler must be brought in for repairs Even though mineral build up and corrosion are not covered under OASIS warranties many customers will want this preventive maintenance which will extend the life of the cooler Instructions for cleaning the hot tank are listed on the following pages Recommended Materials Hot Tank de scaling solution Dissolve 125 grams of citric acid cr
38. r when the hot tank is not completely full of water with all air bled off will cause the heat limiter to break electrical contact When this occurs the heat limiter must be replaced Test Inspect the heat limiter and test for continuity by following the steps listed below 1 Unplug the service cord 2 Visually inspect the heat limiter See if the terminals are bent or broken or the wires are loose 3 Set your volt ohm meter to ohms mode 5 1 OASIS Corporation Testing amp Repairing Cooler Parts 4 Remove both positive and neutral wires from the heat limiter 5 Place one meter test lead on each terminal of the heat limiter 6 There should be a reading continuity should exist Repair Solution A defective heat limiter is replaced not repaired To replace the heat limiter complete the following steps 1 Remove the heat limiter wires 2 Remove the P clamp 3 Remove the heat limiter from its location tube in the base of the hot tank 4 Insert the new heat limiter and reconnect the positive and neutral wires and the P clamp Hot Control The hot control determines the temperature of the water in the hot tank Check Are the terminals of the hot control bent or broken Are the wires of the hot control loose Does the hot control appear to be broken Is the hot control in firm contact with the hot tank Check for continuity Test Inspect the control and test for continuity by following the steps li
39. rting relay Is the PTC relay good Test Test a ceramic relay by substituting known good replacement To test the continuity of a starting relay follow the steps listed below 1 Remove the relay by pulling it off the compressor pins and removing the wire 2 Hold the relay in the upright position see figure 6 3 Set your volt ohm meter to ohms mode 4 Place one meter test lead to the power terminal of the relay and the other meter test lead to the run terminal of the relay 5 If there is a reading continuity exists 6 Turn the relay upside down Place one meter test lead to the power terminal of the relay and the other meter test lead to the start terminal of the relay 8 If there is a reading continuity exists Do not shake the relay to get continuity the armature inside the relay must move freely without any interference 9 If continuity does not exist between power terminal and run terminal and between power terminal and start terminal replace the relay Repair Solution Replace relays as indicated by test results Removable Reservoir The removable reservoir see figure 1 has a capacity of 4 5 litres of water It is a one piece injection moulded part that can be removed quickly for sanitisation and replacement Check Do you see holes or cracks in the reservoir Do you see evidence of mineral build up in the reservoir Are the threads for the faucets damaged 5 15 OASI
40. s common symptoms such as water too cold or frozen and the conditions or parts that may be causing the symptoms Refer to Chapter 5 Testing and Repairing Cooler Parts for instructions on testing repairing and replacing specific parts that may be causing the problem Chapter 4 Easy Solutions discusses three remedies for common problems that do not require repair work power source capacity and cleaning 3 1 OASIS Corporation Symptom No cold water and compressor not running No cold water and compressor running Water too cold or frozen Unit runs noisily No hot water No water flow from hot faucet Troubleshooting Troubleshooting Chart for Bottle Coolers Solution Checklist Page 1 Check voltage received by cooler 4 1 2 Check cold control 5 3 3 Check wires 521 4 Check compressor relay 5 19 5 Check compressor overload 5 18 6 Check compressor 54 1 Check voltage received by cooler 4 1 2 Check for a refrigerant leak 5 18 3 Check for a restriction in capillary line 52 or strainer 4 Check compressor 54 1 Check cold control 53 2 Check for a refrigerant leak 5 18 1 Check for vibrations caused by loose screws 2 Check for vibrations at refrigeration lines 3 Check compressor 54 1 Is switch for hot tank turned off 5 17 2 Check voltage received by cooler 4 1 3 Check heat limiter 335 4 Check hot control 5 5 5 Check wires 521 6 Check hot tank heating element 55 1 Is water bottle empty
41. sted below Unplug the service cord Visually inspect the control See if the terminals are bent or broken or the wires are loose Check that the sensing part of the control is tightly inserted into the relevant tube in the hot tank Set your volt ohm meter to ohms mode Remove both positive and neutral wires from the control Place one meter test lead on each terminal of the hot control There should be a reading continuity should exist If this is not the case replace the hot control If no problems are discovered through the steps above it is possible that the hot control is miscalibrated Since checking calibration requires special equipment OASIS recommends that you simply replace the hot control with a test control that you know is correctly calibrated If the cooler then works properly replace your test control with a new hot control and save the test control for future testing Repair Solution Unless the problem is solved by simply tightening or replacing the mounting screws replace the hot control To replace the hot control complete the following steps 1 Remove the hot control wires You will have already done this if you just tested the control 2 Remove the screws holding the hot control to its mounting bracket and withdraw the sensing bulb of the control from the relevant tube in the hot tank 3 Install the sensing bulb of the new control into the tube on the hot tank and screw the
42. t control that you know is correctly calibrated If the cooler then works properly replace your test control with a new hot control and save the test control for future testing Repair Solution Unless the problem is solved by simply tightening or replacing the mounting screws replace the hot control To replace the hot control complete the following steps 1 Remove the hot control wires You will have already done this if you just tested the control 2 Remove the screws holding the hot control to the hot tank 3 Screw the new hot control to the hot tank and connect the positive and neutral wires careful not to over tighten the mounting screws Doing so will strip the threads and allow the control to move away from the wall of the hot tank Hot Tank The hot tank holds water as it is being heated and stores it until it is dispensed through the hot faucet Check Is the heater element coil of the hot tank defective Is there a short between the heater element coil and the hot tank Do you see holes or cracks in the tank Do you see evidence of mineral build up in the tank Test 1 Visually inspect the hot tank If holes or cracks are discovered replace the tank 2 Test for a short between the heat element coil and the hot tank by following the steps listed below 3 Unplug the cooler 4 Place one meter test lead on one of the heat element terminals 5 Place the other meter test
43. t If this is not the case replace the hot control If no problems are discovered through the steps above it is possible that the hot control is miscalibrated Since checking calibration requires special equipment OASIS recommends that you simply replace the hot control with a test control that you know is correctly calibrated If the cooler then works properly replace your test control with a new hot control and save the test control for future testing Repair Solution Unless the problem is solved by simply tightening or replacing the mounting screws replace the hot control To replace the hot control complete the following steps 1 Remove the hot control wires You will have already done this if you just tested the control 2 Remove the screws holding the hot control to its mounting bracket and withdraw the sensing bulb of the control from the relevant tube in the hot tank 3 Install the sensing bulb of the new control into the tube on the hot tank and screw the body of the control to the mounting bracket Connect the positive and neutral wires Hot Tank The hot tank hold water as it is being heated and stores it until it is released through the hot faucet Check Is the heater element coil of the hot tank defective Is there a short between the heater element coil and the hot tank Do you see holes or cracks in the tank Do you see evidence of mineral build up in the tank
44. the heat limiter wires 25 Remove the screws holding the heat limiter to the hot tank bracket 3 Screw the new heat limiter to the hot tank and connect the positive and neutral wires Hot Control The hot control determines the temperature of the water in the hot tank Check Are the terminals of the hot control bent or broken e Are the wires of the hot control loose Does the hot control appear to be broken Is the hot control in firm contact with the hot tank e Check for continuity Test Inspect the control and test for continuity by following the steps listed below l Unplug the service cord 2 Visually inspect the control See if the terminals are bent or broken or the wires are loose 5 5 OASIS Corporation Testing amp Repairing Cooler Parts 3 Check the tightness of the two mounting screws to ensure that the control makes good contact with the body of the tank Replace any screws with stripped or damaged threads Set your volt ohm meter to ohms mode Remove both positive and neutral wires from the control Place one meter test lead on each terminal of the hot control There should be a reading continuity should exist If this is not the case replace the hot control If no problems are discovered through the steps above it is possible that the hot control is mis calibrated Since checking calibration requires special equipment OASIS recommends that you simply replace the hot control with a tes
45. tube cracked or broken Is the capillary tube in the correct position in the capillary well Test 5 2 OASIS Corporation Testing amp Repairing Cooler Parts Test for continuity by following the steps listed below Note The cold control capillary tube must be warm during this test l Unplug the service cord 2 Visually inspect the control See if the terminals are loose 3 Set your volt ohm meter to ohms mode 4 Remove both positive and neutral wires from the cold control ay Place one meter test lead to each cold control terminal 6 If the meter shows a reading continuity exists and the control is good If the meter shows no reading no continuity exists and the control must be replaced 7 If continuity exists gently move the terminals back and forth to see if continuity is broken CAUTION Never bend terminals since bending could change the calibration of the control Repair Solution A defective cold control is replaced not repaired All cold controls used by OASIS work in the same way However some have an OFF switch and others do not To replace the control complete the steps listed below 1 Locate the capillary tube It is aluminium and comes out of the side or bottom of the cold control and goes into a copper tube built into the probe assembly Place a piece of masking tape around the capillary tube at the point the tube enters the copper capillary well Remove the wires and the two mounting screws from
46. ubmerged in the solution 14 Rinse with clean water immediately 15 Reassemble the water cooler using the sanitised components 16 Sanitise hot tank if fitted and entire cooler with a new batch of sanitising solution 17 Completely fill the cooler with sanitising solution and let stand for 5 minutes 18 Drain solution through hot tank drain tube if fitted or through faucets 19 Rinse with clean water immediately 20 Invert a water bottle on top of the cooler 21 Flush the reservoir at least three times to remove any traces of the sanitisation material 22 Use chlorine test kit to identify the presence of any contaminants 23 Ifcontamination still exists repeat steps 21 and 22 24 Fitthe new air filter to the Waterguard 25 Clean the outside of the cabinet and the drip tray using a mild cleaning agent 26 Reconnect the power supply to the cooler Setting up the water cooler at your premises 1 Examine the packaging for signs of damage report any damage to the haulier 2 Remove the carton from the cooler lie the cooler its side cut open the tape sealing the bottom flaps of the carton and replace the cooler in the upright position Lift the carton from the cooler 3 Remove the shipping bag from the cooler 4 Carry out a general inspection of the cooler ensuring that a There are no marks or physical damage to the cooler b That all accessories are present c Thatthe faucets are tight and in an upright position d
47. ure that the hot faucet is pressed open and the appropriate time is allowed until the hot tank is full i e water flows out of the hot faucet and air stops going back into the bottle 7 Check that water flows through the cold faucet 8 Connect the unit to the electricity supply using the power cord 9 Switch on the hot tank and allow the unit to operate for 25 minutes 10 Using a flash light check through the back of the cooler for water leaks 11 After the unit has operated for 25 minutes check that there is hot water from the hot faucet and cold water from the cold faucet 12 Recheck the cooler for water leaks 13 Ensure that the cooler is in the customer s desired location and that all the accessories are attached to the water cooler OASIS Corporation Troubleshooting Chapter 3 Troubleshooting Discovering the source of a problem is sometimes more difficult and time consuming than actually resolving the problem Chapter 3 presents a troubleshooting chart to help you diagnose problems with OASISQ bottle coolers There are two types of problems you may be called upon to correct l Something is wrong with the cooler Parts need to be set up correctly repaired or replaced 2 Nothing is wrong with the cooler The cooler is not getting power or it is receiving power at the wrong voltage the cooler is being expected to perform beyond its capability or the cooler simply needs to be cleaned The troubleshooting chart list
48. your cooler from water spillage as a result of bottle cracks and also seals the reservoir from dust and other air borne contamination Check Are the plastic parts clean Is the air filter dirty or broken Are all the seals clean and good condition e Is the probe assembly cracked Test Visually check the O rings and seals they are dirty then wash them in soapy water and dry them thoroughly If they are damaged replace them Visually check all of the plastic parts for cracks Repair Solution To clean the WaterGuardG follow the procedure below Grasp the funnel and unscrew the probe assembly Lift off the seal ring and gasket assembly and remove the filter assembly Wash rinse and dry all parts do NOT wash the filter assembly If the filter assembly is dirty or wet replace it Re assemble the parts ensuring the probe is hand tightened to the funnel A res Wires Terminals Connectors Check the electrical diagram in the Service Instructions for the cooler you are repairing to determine the correct configuration of wires This schematic is also displayed on the inside of the cooler Check Is any wire disconnected from a terminal 5 17 OASIS Corporation Testing amp Repairing Cooler Parts Is any terminal loose Is the insulation of any wire broken or frayed Is any wire connected to the wrong terminal Check each wire for continuity Test
49. ystals in 1 litre of hot water Bucket or pan with 8 10 litre capacity Funnel with 8mm diameter end Rubber gloves Repair Solution 1 Disconnect the power supply cord Draw water from the hot faucet until the water is cool Remove the bottle from the unit CAUTION nearly full bottle of water weighs over forty pounds 18 1 kg and can be awkward to handle It may be necessary for you to drain water from the bottle until it becomes manageable Drain water from the reservoir through the cold faucet Place a bucket or pan under the black drain valve located at the rear of the cooler Turn the valve s petcock counter clockwise to open CAUTION HOT WATER CAN SCALD HANDS Turn the drain valve to a closed position when the tank is empty For easy access to the hot tank inlet tube remove the reservoir by unscrewing the cold faucet blue handle and pulling upward on the reservoir s lip 9 Remove the baffle from the reservoir 10 Placeafunnel with an 8 mm diameter end into the supply tube 11 125 grams of citric acid crystals with one litre of very hot water wearing rubber gloves is recommended 12 Carefully pour the hot solution into the funnel BE CAREFUL NOT TO SCALD YOUR HANDS 13 Replace the removable reservoir and the cold faucet er A OASIS Corporation Easy Solutions 14 15 16 17 18 19 20 21 22 23 24 25 Fill the reservoir with bottled water until the water level is 75

Download Pdf Manuals

image

Related Search

Related Contents

Bentel Security KYO320 Manuale Installatore Parte 1    Entrenamiento de abdominales y parte baja de la espalda  "user manual"  LevelOne FCS-4101  Manual de instrucciones Sistemas de seguridad MGB-L0-...AR.  Model 6390 User guide - Fitch Security Integration  Manual Marcador Polo  Formación a distancia de EXPERTO EN DISEÑO  Télécharger  