Home

Aquafresh Watermakers Ltd

image

Contents

1. AQUAFRESH VWATLERMAKERS AFDXXX X AC Series Operators Manual Please read this manual thoroughly before attempting to operate your water maker E amp OE Danger High Voltage AFDXXX X Series water makers operate on a 240VAC electricity supply and must not be opened disassembled or repaired by unauthorised or unqualified service people Improper Operation Or Repair Of Your Water Maker Could Result In Serious Injury or Death Danger Safety nformation The water maker is a high pressure device operating at up to 1000psi and must not be disassembled or repaired by unauthorised or unqualified service people Improper Operation Or Repair Of Your Water Maker Could Result In Serious Injury or Death Before attempting to operate your water maker ensure that seawater intake is fully open and that all pre filters are clean and unblocked Visually check the unit before running for leaks loose fittings and corrosion Do Not Operate Water Maker If You Are Unsure Always ensure the water maker is running at the desired pressure for your area of operation and seawater temperatures refer to full manual If unsure please set running pressure to 25 psi The adjustment is made on the water maker not at the control panel Never Attempt To Run The Water Maker Above 950psi AFD Series water makers are not designed for and will be permanently damaged if operated in brackish or freshwater areas Index Screen
2. Operation Function Page Layout Starting Stopping Semi Auto Freshwater Flushing option Setting Up Freshwater Auto Flush option Winterising De Winterising Errors Faults and Messages 1 Screen Operation Aquafresh Touchscreen AQUAFRESH WATERMAKERS Ver 1 5 2611 RFE Series o B Screen Operation Navigating your Aquafresh Touchscreen is very simple To move between pages simply use the A and y arrows To enter times and or operate functions associated with each function page use the touchscreen To STOP the unit at any time press stop on the Membrane Panel or touchscreen NOTE The screen has a sleep timeout facility after 10 minutes you must wake the screen by a single touch to any part of the touchscreen before it will respond to commands 2 Function Page Layout Function Page Order Serine Ready Screen Fresh Water Flush ia Ea _ Screen Settings Engineering Screen Password Protected NOT FOT CUSTOMER USE 3 Starting Start up screen during power up Scenes _ Unit Stopped Press START ICON to start water maker The following screens will then appear SAFI Valve position check This screen is only visible if the flush option ts installed Low Pressure Pump Started 3 minutes delay before High Pressure pump starts High Pressure Pump Started Short delay before Salinity Module Initialises Starting Continued Salini
3. essages continued No Fresh Water No Fresh Water Investigate cause of alarm Press RESET ALARM to clear Indicates no freshwater was produced for 1 hour Common causes Salinity probe failure or dirty One or more membranes has failed 18 Page Intentionally Left Blank
4. is replaced regularly If your water maker is fitted with the optional freshwater flush system it is possible to Initiate an automatic freshwater flush from the touchscreen With the machine in the stopped mode Unit Stopped Press the vw ARROW Membrane button twice Maintenance Screen Auto Flush OFF Press OFF ICON Maintenance Screen Auto Flush ENABLED With Auto Flush enabled the unit will automatically flush the water maker upon stopping in normal mode and every 7 days for 4 minutes each time CAUTION This feature is designed to be used while the boat is occupied but the water maker is not in regularly use i e when living aboard in harbour Any unattended automated operation of complex machinery carries a risk Reliable operation of this feature is dependent on other vessels systems being available and fault free Aquafresh Watermakers does not recommend the use of this feature when the boat is left unattended for extended periods 12 Setting Up Freshwater Auto Flush continued Should power to the water maker be interrupted at any time Auto Flush Enable feature will be cancelled Press the A ARROW Membrane button twice to return to the normal screen Unit Stopped 13 7 Winterising Due to the chemicals that are used during winterisation and cleaning it is necessary that someone trained in the handling of chemical preservatives and cleaning substances performs this task For winterising options plea
5. se see full service manual for details 14 8 De winterising CAUTION Observe all precautions for handling the chemical cleaning or preservatives that may have been used in your system Ensure the watermakers flushing lever controls are set to normal positions for seawater intake and overboard discharge and that any chemical cartridges are removed and replaced with standard filters With the machine in the stopped mode Unit Stopped Press the v Membrane button twice Maintenance Screen Press DE WINTERISE ICON Maintenance Screen 20 minute De Winterise cycle will start Note The unit de winterising can be stopped at any time by pressing STOP Unit Stopped NOTE In this mode the watermaker will run normally for 20 minutes but will not allow any water to enter the vessels tanks This cycle ensures any preservative or cleaning chemicals present are flushed overboard 15 9 Errors Faults and Messages Your watermaker can display various message that can help diagnose maintenance issues including operational errors and faults Tank Full Optional Tank Full Shutdown Press ACCEPT to clear If you watermaker is fitted with the optional tank full switch the unit will automatically stop once your tanks are full The above message will be displayed Press the ACCEPT ICON to clear the message Change PLC Battery Change PLC Battery System warning message it is very important the PLC internal ba
6. ted with the optional freshwater flush system it is possible to initiate a timed freshwater flush from the touchscreen With the machine in the stopped mode Unit Stopped Press the Vv ARROW Membrane button Fresh Water Flush Set Time Enter desired flush time between 2 and 9 minutes Touch the Set Time area on the screen and enter the flush time required using the ESC SHIFT UP DOWN and ENTER buttons on the touch screen Note The system will not accept less than 2 minutes as a flush time Start Flush Press START FLUSH I CON to initiate the timed flush Flush Time Remaining Once the flushing is complete the unit will return to the normal Stopped screen Note The unit flushing can be stopped at any time by pressing STOP 10 Manual Freshwater Flushing continued Unit Stopped Restart I nhibited Short Delay while internal pressures equalise Unit Stopped 1 6 Setting Up Freshwater Auto Flush option SPECIAL NOTE This systems requires that the vessels pressurised fresh water supply is switched on and that there is plenty of freshwater available to complete the flushing cycle for however long it may be required This system will use freshwater from your vessels water tanks and will use approximately 3 7 litres of water per minute At no time should chlorinated water be allowed to enter the water maker via the vessels freshwater system and it is essential that the inline carbon filter
7. ttery is changed Please refer to service manual SAFI Valve Failure SAFI Valve Failure Investigate cause of alarm Press RESET ALARM to clear If your watermaker has the optional flush system installed this error will be displayed if a problem occurs with the SAFI valve Inspect Clean Repair or Replace SAFI valve 16 Errors Faults and Messages continued Salinity Probe Error Salinity Probe Module Fault Investigate cause of alarm Press RESET ALARM to clear This error indicates a problem with the salinity probe or module Check probe clean or replace probe and or module Low Pressure Alarm Low Pressure Alarm Investigate cause of alarm Press RESET ALARM to clear This is a common alarm and indicates a loss of pressure in the low pressure circuit of the watermaker Common causes Blocked or closed seawater intakes Blocked pre filters Air lock in the low pressure circuit Failure of the low pressure pump Failure of low pressure sensor Incorrect installation Shipside watersystem pressure too low only in flush mode optional High Pressure Alarm High Pressure Alarm Optional Investigate cause of alarm Press RESET ALARM to clear Indicates over pressure in the high pressure circuit of the watermaker Common causes Blockage in the high pressure circuit Blockage in the overboard discharge Operating pressure adjusted to high Failure of high pressure sensor 17 Errors Faults and M
8. ty Module I nitialisation Short delay while salinity module is calibrated Unit running but not making water Short delay while membranes initialise Unit running and producing water Animated screen indicates water production CAUTION Always ensure the watermaker is running at the desired pressure for your area of operation and seawater temperatures refer to full manual If unsure please set running pressure to 825 psi The adjustment is made on the watermaker not at the control panel 4 Stopping Unit Running Screen Displayed Unit running and producing water Animated screen indicates water production Press STOP ICON or stor button to stop watermaker The unit will stop immediately The following screens will then appear Unit Stopped Restart I nhibited Short delay while internal pressures equalise Unit Stopped Ready Press To Start 5 Manual Freshwater Flushing option SPECIAL NOTES This systems requires that the vessels pressurised fresh water supply is switched on and that there is plenty of freshwater available to complete the flushing cycle for however long it may be required This system will use freshwater from your vessels water tanks and will use approximately 3 7 litres of water per minute At no time should chlorinated water be allowed to enter the watermaker via the vessels freshwater system and it is essential that the carbon filter is replaced regularly If your watermaker is fit