1. Advanced display facilities for realtime analysis up to 100MHz Multi source triggering Trigger view as fifth channel Simultaneous display of MTB and DTB Portable with battery operation for field use The PM 3264 offers a unique solution to many timing problems in digital electronics Simultaneous display of 4 or 5 input signals prow lt 2 quick and convenient method for reat naiysis of digital signals both at component and system level A versatile deflection system provides many user benefits For example any com bination of up to five input signals and two different modes can be selected by push buttons The sensitivity of the channels includes 2mV div up to 400V per screen using the standard 1 10 attenuator probes A fle in iggering system allows the main an gt i time bases to be triggered independently by any of the four input channels Also an external trigger and composite trigger are provided The alternate time base facility permits a quick reference for magnified displays with respect to the original waveform The multiple trace display demands a CRT with very high light output Philips has designed aero tube with 17kV pda which provides ain san adequate sharp bright spot With aii ine foregoing facilities the PM 3264 remains a typically compact portable oscilloscope which is also extremely simple to use The various facilities are summarized as fo
2. setting and power cord option In such cases purchase orders should specify one of the following options Universal Euro 220V 16A Option 001 North American 120V 15A Option 003 United Kingdom 240V 15A Option 004 OPTIONAL ACCESSORIES PM 8924 00 PM 8924 20 PM 8928 00 PM 8931 00 PM 8960 03 PM 9381 PM 8976 PM 9366 PM 8980 PM 8991 Oscilloscope trolley PM 8992 66 Accessorypouch Passive probe 1 1 1 5m Passive probe 1 1 2 5m HF passive probe 10 1 1 5m 7 Passive probe 100 1 2pF 1 5m 19 inrackmountadapter _ Oscilloscope camera Camera adapter for fixed use Collapsible viewinghood Long type viewing hood PM 8999 Stand ae PM 8901 Batterypackfor3hourscontinuqus Tea ee i PM8910 Polaroid anti glare filter A eat ae
3. 2MHz 3dB Deflection coefficient 50mV div using EXT connector Uncalibrated continuous control 1 gt 3 When A B C or Dare used sensitivity is 2mvV 5V div Measuring accuracy 3 Phase error 3 at 100kHz MAIN TIME BASE MODES _ Auto Triggered RC time 100ms Single shot Time coefficient 1s 50ns div in 23 calibrated steps in 1 2 5 sequence Uncalibrated continuous contro between steps with UNCAL warning lamp should delayed time base be set out of calibration x 10 magnifier extends max sweep rate to 5ns div Accuracy 2 20 C 30 C 3 5 C 40 C Additional error for magnifier 1 Variabie hold off Sweep hold off time can be increased by a factor of 16 DELAYED TIME BASE Modes Delayed time base starts either immediately after the delay time or upon arrival of the first trigger pulse after the delay time f f l f p 5 In Ex Tr Tri AC Ex th Me 40 Tri Be DE Tri Inte For TIA CZ Ca 3V Cai 6m r E NTIE E ie 2r Time coefficients 0 5s 50ns div in 22 calibrated steps 1 2 5 sequence Uncalibrated continuous control between steps with UNCAL warning lamp should main time pase be set out of calibration x 10 magnifier extends max sweep rate to Sns div curacy Ns 20 C 30 C n s 5 C 40 C Aaditional error for magnifier 1 Calibrated sweep delay l Continuous cali
4. by the PHILIPS organization in your country or by PHILIPS TEST AND MEASUREMENT DEPARTMENT EINDHOVEN THE NETHERLANDS Ambient temperatures Rated range of use 5 C to 40 C Limits for operation 10 C to 55 C Storage and transport 55 C to 75 C Altitude Operating to 5000m 15 000ft Non operating to 15 000m 45 000ft Humidity 21 days cyclic damp heat 25 C 40 C R H 95 Shock 30g half sinewave shock af 11ms duration 2 shocks per direction for a total of 12 shocks Vibration Vibrations in three directions with a maximum of 15min per direction 5 55 Hz and amplitude of 0 7mm and 4g max acceleration Unit mounted on vibration table without shock absorb ing material Recovery time Operates within 30 minutes coming from 10 C soak going into 60 relative humidity at 20 C room condi tions Electromagnetic interference Meets VDE 0871 and VDE 0875 Grenzwertklasse B Safety Safety class according to IEC 348 ACCESSORIES SUPPLIED Front cover with storage space Operating and service manual BNC banana adapter Contrast filter 4x 10 1 attenuator probe PM 8928 00 Collapsible viewing hood Cal terminai BNC adapter ORDERING INFORMATION PM 3264 100 MHZ oscilloscope Power options Philips oscilloscopes are normally delivered in accordance with local power require ments If an alternative power option is required the instrument can be supplied fitted with a different power
5. brated control between 0 and 10 x main time base setting Incremental delay time accuracy 0 2 typical Delay time jitter Better than 1 30 000 ME BASE TRIGGERING ingger source int rna A B C D Composite line External Slope or Level range internal 24div External 1 2Vto 1 2V Trigger sensitivity 30 MHz 100 MHz 0 Sdiv 1 5div Ext 50mV 150mV Trigger coupling DC DC full bandwidth AC 100Hz full bandwidth Ext trigger input impedance 1MQ 2 in parallel with 15pF approx Maximum allowable input voltage EANG fan ACpk ar jitter than 0 5ns DELAYEDTIME BASETRIGGERING Trigger source Internal A B CorD For Slope Level range and Sensitivity see MAIN TIME BASE TRIGGERING CALIBRATION rated voltage 3v 1 square wave Calibrated current 6mA 2 square wave 2 MODULATION Input DC coupled TTL compatible HIGH level blanks the display incut impedance Maximum input voltage 50V P Response time 35ns POWER Line voitages and frequencies AG 100 127V and 220 240V 46 440Hz G 250 350V Power consumption 50W at nominal line voltage Dimensions and weight wxhxd 316 x 154 x 460mm 12 4 x 6 1 x 18 in 11kg 241b ENVIRONMENTAL CAPABILITIES The environmental data is valid only if the instrumentis checked in accordance with the official checking procedure Details of these procedures and failure criteria are supplied on request
6. ery easy operation PM 3264 is a highly sophisticated instru ment but the front panel could not possibly be simpler or more logical Channel selec tion is made for example directly above the relevant channel controls Trigger selection ior main and delayed time bases is also logically grouped This simplifies and speeds up measurements and allows the oscilloscope to be used for virtually all appli cations and production testing In addition the PM 3264 is light easy to transport and hence ideal for field work a facility that can be extended via the optional battery pack 4 channel display with trigger view showing relation Glitch has been picked out from channel A and is clearly displayed using the alternate time base mode CRT Type Philips rectangular domed mesh type tube with 17kV acceleration potential and metal backed phosphor Screen type P31 GH phosphor standard Useful screen area 8x 10div of full centimeters Graticule Internal graticule with centimeter divisions and 2mm Subdivisions along the central axes 10 and 90 lines are indicated Illumination continu ously variable VERTICAL OR Y AXIS Response DC 0 H2 100 MHz 35 MHz at 2mV AC 7 Hz 100 MHz Rise time 3 5ns Deflection coefficients 2mv 5V div in steps in 1 2 5 sequence Uncalibrated continuous control between steps 1 gt 2 5 Display modes ChanneiA B CorD A B C D Trigger view any combination o
7. f these channels Multiple display chopped at 1 MHz or Alternate Any channel may be inverted except Trigger view CMRR gt 100 1 up to 2 MHz gt 20 1 at 50 MHz Input impedance 1MQ 2 in parallel with 15pF approx RC time AC coupled 22ms Maximum input voltage 400Vp ACpp derating above 500kHz Maximum deflection Undistorted deflection of 24div up to 35MHz Shift range 16div Signal delay 15ns visible delay Trigger view Display External or internal trigger signal Deflection coefficient external 100 mV div Trigger point Screen centre 0 3div Time delay between vertical input and external input ns Fully independent triggering allows delayed time base to be set to trigger on channel A which allows detailed investigation at any time base speed TECHNICAL SPECIFICATION HORIZONTAL OR X AXIS Horizontal defiection can be obtained from either the main time base or the delayed time base or a combina tion of the two or from the signal source selected for X deflection In this case X Y diagrams can be displayed using A B C or D the EXT connector or the Line as a signal source Horizontal display modes Main time base Main time base intensified by delayed time base Delayed time base Main time base and delayed time base simultane ously dispiayed alternate X Y operation with X deflection by A B C D line or Ext source HORIZONTAL AMPLIFIER Response DC
8. llows fr She Muiti source triggering to add display flexibility N trigger view to relate triggering directly to the four channel display other features like differential displays and composite triggering to extend per formance two time bases to allow signal detail to be cet Sut from the data stream ative time base mode to allow Signai details to be directly related to data Stream annels to show signal relation ma wile oor facilities can be permutated with tually no limitation For example main a delayed time bases can be a pendently triggered from any of the four ee Or the alternate time base mode employed with a differential display aed yet net en ee et sin mee ee C aac sinju Ci 5 ab 3 and the original four channels to give a 12 trace display Trigger view PM 3264 features the ultimate in multi sourced triggering with independent selec tion of main and delayed time bases from any of the four channels plus composite line and external triggering on the main time base It is therefore essential that the relationship between the various displays and the triggering signal is always clear and this is provided by the trigger view facility At the touch of a button the actual trigger signal is displayed as a fifth channel so that there can be no possibility of display ambiguity Alternate time base mode This mode is ob
9. tained simply by pushing both the main and delayed time base controls together It enables the delayed time base signal details to be displayed at the same time as the intensified main time base signals In this way signal details can be directly related to the data stream X Y displays X Y displays are further evidence of the advanced display capability of the PM 3264 The independent triggering facilities allow any one of four channels to be displayed against an X input signal or against any of the four vertical inputs Composite triggering Single channel triggering shows the exact relationship between the displayed signals Composite triggering however allows sig nals that are not related in time or phase to be displayed and compared This facility can be used in a variety of ways for example rise times or waveform aberrations can be compared and measured regardless of the All channels can be inverted and combined for obtaining differential displays The oscillogram shows how noise is suppressed by addition of two balanced signals displayed on channel Aand B ae ee ee ship of all signals to the external triggering source Note the high light output levels time span between signals or the frequency relationship Logic triggering too The PM 3264 is the ideal compliment to a logic analyzer since it shows realtime relationships and signal details such as glitches in their actual analog waveform V
Download Pdf Manuals
Related Search
Related Contents
SUPER RAPIDO K-1 主取扱説明書 ZT210/ZT220/ZT230 - Guia do Usuário (pt-br) Westinghouse 11 Watt Reflector Dimmable LED Light Bulb 0301000 Specification Sheet MULTI-ROTOR PUMPS X10 Wireless Technology MS12A User's Manual BRACELET INSTRUCTION MANUAL watch our centro estadual de educação tecnológica paula souza CombiSolar 150 Installation and Service Manual Copyright © All rights reserved.