1. If it does the regulator may be defective Other suggestions a Verify all burners are clear of debris spider webs or any obstructions b Verify voltage output to gas valve from PC board could be incorrect or intermittent due to a bad component on PC board replace PC board c Ensure correct wiring harness is plugged into correct solenoids on gas valve If you replaced the gas valve you could have mixed crossed the wiring harnesses up d Check resistance readings to all gas valve solenoids refer to tech sheets or service manual for proper values e Check for proper voltage to gas valve solenoids when unit is trying to fire proper voltages can be found in tech sheets or service manual Replace PC board If PC board is replaced refer to service manual for proper dip switch and gas pressure setting procedures 9 06212013GW Code 68 or 14 Troubleshooting Procedure Overheat Safety Device High limit temperature thermistor or thermo fuse has activated WARNING You must be qualified to perform service on electrical and gas systems to proceed Turn off the electrical and gas supply before replacing or servicing any parts 1 10 11 12 13 Verify appliance air filters are not clogged Verify the unit is connected to the proper gas type see rating plate for gas type of unit Check to ensure this unit has ever been converted from one gas type to another If it was converted verify conversion was performed per manuf
2. 212013GW e Check for proper voltage to gas valve solenoids when unit is trying to fire proper voltages can be found in tech sheets or service manual Replace PC board If PC board is replaced refer to service manual for proper dip switch and gas pressure setting procedures 7 06212013GW Code LO or 12 Troubleshooting Procedure Flame Failure WARNING You must be qualified to perform service on electrical and gas systems to proceed Turn off the electrical and gas supply before replacing or servicing any parts 10 11 Verify circuit feeding appliance is properly grounded Should have a three prong plug and receptacle feeding the appliance that is grounded and bonded to the circuit panel and ground rod to the home Verify all gas valves on gas system are open feeding the proper gas pressure to said appliance Verify all air was purged from gas lines after installation Verify proper inlet gas pressures are being fed to appliance Check appliances rating plate for proper pressures This plate or label is located on the side of each unit The minimum listed inlet pressure MUST be maintained with all gas appliances at the location firing on high fire Verify proper gas type ensure the gas supply at this location matches that listed on said appliance Verify gas type dip switch on PC board is switch to proper gas type position for older models On newer models this can be done through the control panel electronically See gas pressur
3. ING You must be qualified to perform service on electrical systems to proceed Turn off the power supply before replacing or servicing any parts 1 Inspect the room temperature thermistor wiring harness for loose connectors damage or broken wires 2 Ohm out room temperature thermistor to determine if the thermistor is open See service manual for proper resistance values 3 Verify room temperature thermistor is not sensing cold air from an opening behind the unit such as an unsealed gas line or vent terminal penetration through an outside wall Other items that could cause cold drafts across the thermistor are a Air leaks around doors or windows near the unit b Un insulated walls behind or around the unit Cold air entering the room drops to the floor and is drawn to the unit when the appliance is firing Move the room temperature thermistor up higher behind unit or just outside the rear covers to see if room temperature drops to unit s set point 4 Replace room temperature thermistor 13 06212013GW Code 64 68 72 or 33 Troubleshooting Procedure High Limit Thermistor Disconnected WARNING You must be qualified to perform service on electrical systems to proceed Turn off the power supply before replacing or servicing any parts 1 Verify air filters are not clogged 2 Inspect the high limit thermistor wiring harness for loose connectors damage or broken wires 3 Ohm out high limit thermistor to determine if the th
4. Rinnai Direct Vent Heaters Troubleshooting Manual AWARNING There are a number of live tests that are required when fault finding this product Extreme care should be used at all times to avoid contact with energized components inside the furnace You MUST be a qualified service person before proceeding with these test instructions Before checking resistance readings turn off power source to unit and then isolate each item to be checked from the circuit by unplugging it When setting gas pressures on one of these units please check the complete model number you are trouble shooting Gas pressures and dip switches can vary among models Always check the rating plate for complete information and follow directions caution Label all wires prior to disconnection when If any of the original wire as supplied with the appliance must servicing controls Wiring errors can cause be replaced it must be replaced with type 18 AWG wire or its improper and dangerous operation equivalent 1 06212013GW Table of Contents Code Numbers Page LO His Analog Md id a 4 PE Digital REA Olite etc 4 60 A alog Indicato Frias iii 5 RO NS 5 LOS Analog Adicto bee i 8 TL Digital Read OUt canoa ives A A AA i e tae 8 68 amp Analog Indicator oea ei A a a A E deudlulowsdsudbuiecsosedetdsssiee douse 10 14 Digital Read Otura e iii 10 Al Analog Indicator serne itiiti hic ccdesa seca castcdie cut cstusstdavencutediecutsstdevssesd ceuk
5. ack to PC board 2 Replace ON OFF switch 18 06212013GW Code LO 60 or 71 Troubleshooting Procedure Main Solenoid SV1 SV2 SV3 PVO Solenoid Valve Fault WARNING You must be qualified to perform service on electrical and gas systems to proceed Turn off the gas and power supply before replacing or servicing any parts 1 Check wiring harnesses to all solenoid valves for loose broken or damaged connections from gas valve solenoids back to PC board 2 Check voltage to all solenoid valves while the unit is trying to fire If you have proper voltage but keep getting an error code proceed to the next item 3 Measure the resistance of all solenoid valves if any of the solenoid valves are found to be open meaning having no resistance replace the gas control valve 4 Ifyou are still getting a code 71 replace the gas control valve You may get a good resistance reading upon unplugging the wires however under load it could open or you may have a mechanical problem inside the valve that won t allow the valve open 5 Replace PC board If PC board is replaced refer to service manual for proper dip switch and gas pressure setting procedures 19 06212013GW Code 80 or 72 Troubleshooting Procedure Flame Rod Failure WARNING You must be qualified to perform service on electrical and gas systems to proceed Turn off the gas and power supply before replacing or servicing any parts 1 Verify the proper flame rod wire is plugged int
6. acturer s specifications See conversion procedure for the model number unit at your location Verify proper clearances were maintained around unit and vent terminals Inspect the safety circuit wiring harness for loose connectors damage or broken wires Ohm out safety circuit to determine if the bi switch is open or if the issue is a blown thermo fuse Replace any damaged or blown thermo fuses Before replacing those components complete the inspection of all items listed below to find your root cause for the failure Verify all dip switches are set per manufacturer recommendations contact Rinnai for details on proper settings if you need assistance Verify low and high fire manifold gas pressures check using a manometer Procedure for checking these pressures can be found in the service manual If you need assistance contact Rinnai technical services 24 7 for details on now to check these pressures You must have a manometer to check operating gas pressures Inspect burner manifold burner assembly for debris build up or blockage If you find debris build up inside the burner assembly clean it out If heat burner assembly shows signs of excessive heat replace the heat exchanger Inspect the front sides and back of the heat exchanger surface for cracks separations discoloration or damage of any kind If you find any of the above mentioned items replace the heat exchanger Inspect all components inside the unit s cabinet for sign
7. anual for proper dip switch and gas pressure setting procedures 4 06212013GW Code 60 or 11 Troubleshooting Procedure Missed Ignition Flame rod current does not reach 1 micro amp within a certain time after the solenoid opens WARNING You must be qualified to perform service on electrical and gas systems to proceed Turn off the electrical and gas supply before replacing or servicing any parts 10 Verify circuit feeding appliance is properly grounded Should have a three prong plug and receptacle feeding the appliance that is grounded and bonded to the circuit panel and ground rod to the home Verify all gas valves on gas system are open feeding the proper gas pressure to said appliance Verify all air was purged from gas lines after installation Verify proper inlet gas pressures are being fed to appliance Check appliances rating plate for proper pressures This plate or label is located on the side of each unit The minimum listed inlet pressure MUST be maintained with all gas appliances at the location firing on high fire Verify proper gas type ensure the gas supply at this location matches that listed on said appliance Verify gas type dip switch on PC board is switch to proper gas type position for older models On newer models this can be done through the control panel electronically See gas pressure sitting procedure for appliance you are working on for details Verify igniter is working Turn off gas valve feeding th
8. cusieuisetdcrececeiedestes 11 16 Dieta REQUENA ia dois 11 P22 IGS ANAlO SINAC ATO tesssies ao savesavactes 12 Se Digital CAG DUE a A AA vk Gah it 12 76 80 5 An log INGICATOR mesial iento saab 13 32 Digltal Read OU IO Nan dada ta Iba a isa 13 64 68 72 Analog Indicativos taaan craneales dan E EE 14 33 Digital RE Dit a Cot a a AE iaa deed oth oth 14 68 72 76 Analog Indicato ses ac ccssescteicstecedcdesessves a e cbantulteh eDarsncbwelededaeunrerretteesarwenessdvrwateseneaeate 15 34 Digital Read O 1 idad E antes cai cds ad dad Aid acid 15 LO 60 64 Analog dica tii A dni 16 53 Digital REA Dit A A cde sub csea cele ces A E iaa 16 60 64 68 Analog Indicatot gnane i ee e da dae oa censos odias 17 61 Digital R Aq Ot ua A E iaa Dad id id Aida a 17 64 68 Analog Indicator ii did 18 AQ Digital Eo ROT i EAA EE EE A da 18 ES e O Analog Odia da EAEE T S 19 2 06212013GW 71 gt Digital Read Dti ci rd ai Aa AA aa dai 19 BOS Analog ndice adds 20 72 Digital Read DUE a aia 20 12 70 80 Analog Indicator ii dai did 21 13 Digital Read OU A diia 21 49 NN 22 A NA 23 How to retrieve codes from analog or digital key panel o oocnconcniniciccionicnincocononcn noo noocononoronanononnnn nos 24 Rinnai America Corporation 103 International Drive Peachtree City GA 30269 Toll Free 1 800621 9419 e Phone 678 829 1700 e www rinnai us O 2013 Rinnai America Corporation Rinnai is continually updating and improving product
9. d If PC board is replaced refer to service manual for proper dip switch and gas pressure setting procedures 22 06212013GW Code 99 Troubleshooting Procedure Air Supply or Exhaust Blockage WARNING You must be qualified to perform service on electrical and gas systems to proceed Turn off the gas and power supply before replacing or servicing any parts Inspect the entire vent system inside outside the home or business Verify all clearances were met and the proper vent materials were used 1 10 11 12 Perform this test only if the unit is coding out during your service call Remove the intake and exhaust pipe behind the unit fire the product and see if it will operate without the vent system connected If the unit operates without coding out at that point that s a great indication the problem is in the vent system CAUTION Never leave a unit operating without the vent system properly connected The test mentioned above is only that a test If the unit functioned with the vent disconnected there is a 99 9 chance the issue is in the vent system Proceed to the next step below Verify each section of vent was installed properly Inspect the vent system to ensure all clearances around vent terminations were met Improper clearances will result in recirculation of combustion gases Make sure the vent length was not exceeded The proper vent lengths are thirteen total feet with no more than an eight foot vertical rise and n
10. e appliance Unplug igniter wire hold the igniter wire with an insulated pair of pliers about a 1 4 from a piece of metal Cycle the unit to ensure you see a spark when unit is cycling If not check ignition system for loose connections damaged components or disconnected plugs back to PC board If no spark is noted check the ignition board to verify it is getting the proper voltage from the PC board See service manual for proper voltage and connector numbers Note there will be no voltage present unless the unit is going through the ignition cycle Make sure the ceramic sparker electrode is tight in its mounting bracket You should not be able to move it with your finger if gasket is intact If loose remove it and clean with dollar bill Reinstall using new gasket and ensure it is tight when the installation is finished If the electrode is loose the tip can drop down and touch the burners creating a short or no spark Verify the proper flame rod wire is plugged into the proper flame rod on said unit Some units have multiple flame rods Verify the flame rod is tight in its mounting bracket You should not be able to move it with your finger if gasket is intact If loose remove it and clean with dollar bill Inspect flame rod for cracks Reinstall using new gasket and ensure it is tight when installation is finished 5 06212013GW 11 12 13 14 15 16 17 18 Look into view window on appliance to see if you ever s
11. e correct position 9 Verify all burner cassettes are in place in burner rack Sometimes when a unit is dropped the burners can shift and become dislodged If you find the burners dislodged loosen the burner bracket and reseat them 16 06212013GW Code 60 64 68 or 61 Troubleshooting Procedure Abnormal Combustion Fan Motor RPM WARNING You must be qualified to perform service on electrical systems to proceed Turn off the power supply before replacing or servicing any parts 1 Check wiring harness for loose broken or damaged connections from fan motor back to PC board 2 Remove fan motor with power supply to product turned off Inspect blower wheel to ensure it turns freely 3 Check fan housing and blower wheel for obstacles that could prevent it from turning 4 Measure fan motor winding resistance see service manual or troubleshooting sheets for proper resistance readings If windings are open replace motor 5 If motor windings are within specifications and fan motor turns freely replace PC board If PC board is replaced refer to service manual for proper dip switch and gas pressure setting procedures 17 06212013GW Code 64 68 or 70 Troubleshooting Procedure ON OFF Switch Failure WARNING You must be qualified to perform service on electrical systems to proceed Turn off the power supply before replacing or servicing any parts 1 Check wiring harness for loose broken or damaged connections from ON OFF Switch b
12. e sitting procedure for appliance you are working on for details Verify the proper flame rod wire is plugged into the proper flame rod on said unit Some units have multiple flame rods Verify the flame rod is tight in its mounting bracket You should not be able to move it with your finger if gasket is intact If loose remove it and clean with dollar bill Inspect flame rod for cracks Reinstall using new gasket and ensure it is tight when installation is finished Look into view window on appliance to see if you ever see a flame in the burner box while the unit is going through the ignition cycle If you do that indicates an issue in the flame rectification circuit This could be a buildup of carbon or a white substance on flame rod bad connection at flame rod loose or damaged flame rod bad PC board gas valve or low inlet gas pressures Before replacing the PC board or gas valve continue troubleshooting the steps below Remove flame rod and inspect them for carbon or a white substance build up Clean both the igniter and flame rod before reinstalling In addition inspect the burners under the igniter for debris or condensate build up Blow out burners and burner box with 120 psi of air If you remove just the igniter and flame rod assemblies make sure you have a new flame rod igniter gasket This gasket MUST be replaced if this seal is broken If you note improper inlet gas pressures check to see if the gas system was properly sized If yo
13. ee a flame in the burner box while the unit is going through the ignition cycle If you do that indicates an issue in the flame rectification circuit This could be a buildup of carbon or a white substance on flame rod bad connection at flame rod loose or damaged flame rod bad PC board gas valve or low inlet gas pressure Before replacing the PC board or gas valve continue troubleshooting the steps below Remove igniter and flame rod and inspect them for carbon or a white substance build up Clean both the igniter and flame rod before reinstalling In addition inspect the burners under the igniter for debris or condensate build up Blow out burners and burner box with 120 psi of air If you remove just the igniter and flame rod assemblies make sure you have a new flame rod igniter gasket This gasket MUST be replaced if this seal is broken If you note improper inlet gas pressures check to see if the gas system was properly sized If you are in doubt on how to size the gas system gas piping regulator or tank contact your utility company or a professional gas technical or master plumber for assistance Refer them to the International Plumbing Code Book for proper sizing Inspect the vent system for loose joints improper fittings failure to meet clearances around vent terminal outside building See venting instructions for clearance specifications Failure to meet vent terminal clearances can lead to recirculation of combustion gases causing incom
14. ermistor is open See service manual for proper resistance values 4 Replace high limit thermistor 14 06212013GW Code 68 72 76 or 34 Troubleshooting Procedure High Limit Thermistor Short Circuit WARNING You must be qualified to perform service on electrical systems to proceed Turn off the power supply before replacing or servicing any parts 1 2 Verify air filters are not clogged Inspect the high limit thermistor wiring harness for loose connectors damage or broken wires Ohm out high limit thermistor to determine if the thermistor is open See service manual for proper resistance values Replace high limit thermistor 15 06212013GW Code LO 60 64 or 53 Troubleshooting Procedure Abnormal Spark Sensed WARNING You must be qualified to perform service on electrical systems to proceed Turn off the power supply before replacing or servicing any parts Sparker doesn t shut OFF within 20 seconds at time of ignition 1st spark was not sensed within two seconds second spark sense was not continuous for one second after solenoid valve opens 1 Inspect the igniter wire for a loose connection damage or broken wire 2 Is spark generator igniter module firmly attached to the appliance s cabinet with a screw It is important to have this devise firmly attached for proper ground and proper ignition 3 Verify igniter is working Turn off gas valve feeding the appliance Unplug igniter wire hold the igniter wire wit
15. g harness for loose connectors damage or broken wires 7 Ohm out room temperature thermistor to determine if the thermistor is open See service manual for proper resistance values 8 Replace room temperature thermistor 11 06212013GW Code 72 76 or 31 Troubleshooting Procedure Room Temperature Thermistor Disconnected WARNING You must be qualified to perform service on electrical systems to proceed Turn off the power supply before replacing or servicing any parts 1 Inspect the room temperature thermistor wiring harness for loose connectors damage or broken wires 2 Verify room temperature thermistor is not sensing cold air from an opening behind the unit such as an unsealed gas line or vent terminal penetration through an outside wall Other items that could cause cold drafts across the thermistor are a Air leaks around doors or windows near the unit b Un insulated walls behind or around the unit Cold air entering the room drops to the floor and is drawn to the unit when the appliance is firing Move the room temperature thermistor up higher behind unit or just outside the rear covers to see if room temperature drops to unit s set point 3 Ohm out room temperature thermistor to determine if the thermistor is open See service manual for proper resistance values 4 Replace room temperature thermistor 12 06212013GW Code 76 80 or 32 Troubleshooting Procedure Room Temperature Thermistor Short Circuit WARN
16. h an insulated pair of pliers about a 1 4 from a piece of metal Cycle the unit to ensure you see a spark when unit is cycling If not check ignition system for loose connections damaged components or disconnected plugs back to PC board If no spark is noted check the ignition board to verify it is getting the proper voltage from the PC board See service manual or troubleshooting data sheets for proper voltage and connector numbers 4 Make sure the ceramic igniter electrode is tight in its mounting bracket You should not be able to move it with your finger if gasket is intact If loose remove it and clean with dollar bill Reinstall using new gasket and ensure it is tight when the installation is finished If the electrode is loose the tip can drop down and touch the burners creating a short or no spark 5 Remove igniter and inspect it for carbon or a white substance build up Clean the igniter before reinstalling In addition inspect the burners under the igniter for condensate build up spider webs or debris Blow out burners and burner box with 120 psi of air Anytime you remove the igniter make sure you have a new igniter gasket This gasket MUST be replaced if this seal is broken 6 Check igniter gap see service manual for gap setting normally about 3 16 7 Verify proper altitude settings see high altitude gas pressure setting procedure for dip switch and manifold gas pressure settings 8 Verify spark electrode is installed in th
17. ime for 2 5 seconds with the unit in the OFF position Release the buttons and then the error codes will be displayed in sequence The previous faults will be displayed as follows The most recent fault is displayed first followed by up to 10 other faults if they have occurred If you miss the codes as they are displayed wait until the LED turns off and repeat the procedure for recalling the faults again The codes will be displayed on the units depending on the model number that you are servicing as follows ALL FURNACES having analog displays with temperature indicator lights LO 60 64 68 72 76 80 HI Example 60 64 68 Abnormal combustion fan motor RPM s ALL FURNACES having digital LED temperature displays Examples SET ROOM 1 53 2 14 1 First code and most recent 53 Abnormal spark sensed 2 Second code 2 most recent 14 Overheat safety has tripped On the RHFE263 and RHFE1004 Series product the temperature display shows either the temperature or error code 01 71 Example 01 most recent then fault code such as 71 indicating a faulty gas solenoid valve The number such as 01 will appear followed by the fault code then 02 followed by the second fault code 03 followed by the third fault code and so on 24 06212013GW
18. o more than two elbows See venting instructions for further details Inspect vent termination for ice build up inside or around air chamber outside structure Remove vent termination and inspect for debris inspects water or ice in vent system Disconnect all vent joints looking for water condensation inspects or other items Verify vent terminals are installed with the proper clearance from overhangs grade obstructions walls porches etc Must be at least 12 from window or doors and 12 above grade or the highest anticipated snow load See venting instructions for further clearance requirements Remove fan motor and inspect fan wheel housing and air duct for any type restriction Remove burner manifold and inspect for insects or other debris in air channel for restriction Verify low and high fire manifold pressures are set correctly See gas pressure setting procedure for proper settings 23 06212013GW 13 Replace fan motor 14 Replace PC board If PC board is replaced refer to service manual for proper dip switch and gas pressure setting procedures How to retrieve codes from analog or digital panels All Rinnai EnergySavers with LED have self diagnostic codes to assist the technician in troubleshooting the product Information about the previous faults is stored in the PC board and can be recalled during servicing by pressing the ECONOMY button and the temperature control UP amp DOWN buttons at the same t
19. o the proper flame rod on said unit Some units have multiple flame rods 2 Make sure the ceramic on the flame rod or rods is not cracked or damaged 3 Inspect condition of flame rod portion inside burner to ensued it s not broken or damaged 4 Replace flame rod or rods 20 06212013GW Code 72 76 80 Hl or 73 Troubleshooting Procedure Communication Failure WARNING You must be qualified to perform service on electrical systems to proceed Turn off the power supply before replacing or servicing any parts Data transfer between CPU and E2PROM failed 1 Unplug power to unit and then reapply to see if code goes away 2 Replace PC board If PC board is replaced refer to service manual for proper dip switch and gas pressure setting procedures 21 06212013GW Code 49 Troubleshooting Procedure Pressure Sensor Break Down of Disconnected WARNING You must be qualified to perform service on electrical systems to proceed Turn off the power supply before replacing or servicing any parts 1 Check wiring harnesses to air pressure switch for loose broken or damaged connections from pressure switch back to PC board 2 Check air pressure switch hoses to blower motor housing in rear of unit for blockage or spider webs inside hoses 3 Check to ensure plastic hose connections on rear of unit are not broken or damaged 4 Check hoses for cracks or deterioration replace if needed 5 Replace air pressure switch 6 Replace PC boar
20. plete combustion which will lead to carbon build up on flame rods In addition ensure vent length is within specifications jumpers are placed in the correct position and dip switches for vent lengths has been properly set Verify the proper venting materials were used at this installation site See Rinnai venting instructions for details Verify proper altitude settings have been met see high altitude gas pressure setting procedure for dip switch and manifold gas pressure settings Check to ensure all two stages regulators are installed at least six foot away from appliance Ensure when appliance shuts off the pressure from the two stage regulator doesn t exceed the maximum inlet pressure for the appliance To verify this connect your manometer up to the heater s gas test port The inlet pressures should never exceed 10 inches water column for natural gas or 13 5 inches on propane If it does the regulator may be defective Other suggestions a Verify all burners are clear of debris spider webs or any obstructions b Verify voltage output to gas valve from PC board could be incorrect or intermittent due to a bad component on PC board replace PC board c Ensure correct wiring harness is plugged into correct solenoids on gas valve If you replaced the gas valve you could have mixed crossed the wiring harnesses up d Check resistance readings to all gas valve solenoids refer to tech sheets or service manual for proper values 6 06
21. s therefore specifications are subject to change without prior notice Local state provincial and federal codes must be adhered to prior to and upon installation 3 06212013GW Code LO HI or PF Troubleshooting Procedure Power Failure Electric power has been lost while the appliance was running WARNING You must be qualified to perform service on electrical systems to proceed Turn off the power supply before replacing any parts or fuses 1 Ensure power supply is on Check with meter at receptacle if unsure If you do not have a meter plug lamp into receptacle and test 2 If you have no power at the receptacle check fuse or circuit breaker feeding this circuit 3 Verify safety circuit over heat switches OHS or thermo fuse circuit is not open 4 Check fuse inside unit If blown replace with proper size fuse see markings on fuse for size or owner s manual 5 If fuse is not blown check to see if your unit has a transformer in it If it does check for proper transformer output voltage of each windings or read resistance through each set of windings See service manual section under troubleshooting or fault finding for proper voltage readings or resistance values for each windings If you fall to get a voltage reading or resistance readings across either winding replace the transformer 6 Ifthe transformer is ok or the unit doesn t have a transformer replace the PC board If PC board is replaced refer to service m
22. s of excessive heat damage Take note of the area around the burner site glass and gasket If discoloration black surface is noted replace heat exchange Verify venting is within vent clearance specifications and lengths per manufactures recommendation If code 14 still appears after performing the above inspections replace PC board If PC board is replaced refer to service manual for proper dip switch and gas pressure setting procedures 10 06212013GW Code HI or 16 Troubleshooting Procedure Over Temperature Cut Off WARNING You must be qualified to perform service on electrical and gas systems to proceed Turn off the electrical and gas supply before replacing or servicing any parts Room temperature is sensed as being above 104 F for longer than 10 minutes 1 Verify air filter is not clogged 2 Verify the unit is connected to the proper gas type see rating plate for gas type of unit 3 Check to ensure this unit has ever been converted from one gas type to another If it was converted verify conversion was performed per manufacturer s specifications See conversion procedure for the model number unit at your location 4 Verify proper clearances were maintained around unit and its vent termination see owner s manual for proper clearance requirements 5 Verify vent terminal is not blocked may have to disassemble to inspect inside termination air exhaust chambers 6 Inspect the room temperature thermistor wirin
23. u are in doubt on how to size the gas system gas piping regulator or tank contact your utility 8 06212013GW 12 13 14 15 16 company or a professional gas technical or master plumber for assistance Refer them to the International Plumbing Code Book for proper sizing Inspect the vent system for loose joints improper fittings failure to meet clearances around vent terminal outside building See venting instructions for clearance specifications Failure to meet vent terminal clearances can lead to recirculation of combustion gases causing incomplete combustion which will lead to carbon build up on flame rods In addition ensure vent length is within specifications jumpers are placed in the correct position and dip switches for vent lengths has been properly set Verify the proper venting materials were used at this installation site See Rinnai venting instructions for details Verify proper altitude settings have been met see high altitude gas pressure setting procedure for dip switch and manifold gas pressure settings Check to ensure all two stages regulators are installed at least six foot away from appliance Ensure when appliance shuts off the pressure from the two stage regulator doesn t exceed the maximum inlet pressure for the appliance To verify this connect your manometer up to the heater s gas test port The inlet pressures should never exceed 10 inches water column for natural gas or 13 5 inches on propane