Home

Service Manual – TCT & PTT

image

Contents

1. 16 63 42 2 _ f EE Nes Ea SE 38 50 j 97 8 cm F TCTT 34 25 27 00 26 50 i 87 0cm 6 6 67 3 cm 20 88 TCTS TCTT TCTT 53 0 cm 22 75 22 25 i 57 8 cm TCTS 13 38 34 0 kK 9 13 7 2 2 23 2 cm 1 25 3 2 cm PTT ROUGH IN DRAWING 20 88 53 0 cm b i 4 22 88 9 13 58 1 cm 23 2 cm 11 TEA TIPS WARNING DO NOT refrigerate unused tea overnight for later consumption CLEANING IMPORTANT If the brew cone comes with screen clean the screen to maintain the tea flow Neglecting this screen will eventually cause the brewcone to overflow spilling hot liquid over the unit CAUTION DO NOT use undiluted bleach or chlorine LIQUID LEVEL PROBE 12 1 Store tea bags in a dark cool and dry place away from strong odors and moisture Do not refrigerate 2 Never hold finished brewed tea for more than eight hours at room temperature Discard any unused tea after eight hours 3 Brew only enough tea that you reasonably expect to serve within a few hours 4 To protect tea flavor and to avoid bacterial contaminat
2. z All programming selections are performed with the three center buttons CLE The symbols below the buttons are PROGRAM MODE 4 Scroll LEFT SELECTION or ENTER to save new parameter 1 2 3 4 GRAY BREW gt Scroll RIGHT SPRAYHEADS Mentioned in this Programming guide are the words Gray and Purple This refers to the color of the sprayhead The current sprayhead is the purple AFS The older version is the gray sprayhead See the illustration at right PURPLE Programming Program Menus Tea Recipes Tea By Volume Tea By Time Tea Dilut Delay Tea Dilut Volume Tea Dilut Time Tea Dilut Stir Tea Pulse Brew Tea Fast Brew Tea Half Batch Tea Drip Out Temperature Energy Save Mode Program Menus screen Press gt button to show the next menu item Tea Recipes Factory set to Standard Tea Purple Press to Select Press lt or gt to scroll through recipes Standard Gray Standard Purple Tropical Gray Tropical Purple 76 308 Gray or 76 308 Purple Press to set Tea by Volume Press to select Display will now show Push START To Begin Press the BREW button then hot water starts running when desired volume is reached press BREW button again to stop the flow Now the volume has been set Pressing gt button will display the subsequent menu features
3. and COMBO SWEET Press to set When the Model Select feature is changed all settings are reset to the defaults of the newly selected model Exit Press to select exits program mode and returns unit to operation Pressing gt returns you to Tea Recipes Illustrated Parts TCT ITEM PART N DESCRIPTION 1 WC 3301 BASKET WIRE 7 00 DIA USE WITH WC 3311 OPTNL 2 WC 3647 STRAINER BT 10 BREWCONE EXCEPT PARADISE 2A WC 8532 STRAINER TROPICAL BREWCONE 3 WC 3320 BREW CONE W HANDLE 8 8 D W STRNR OPTIONAL 4 WC 3201 HANDLE BREW CONE BLACK FOR WC 3320 5 WC 3398 BREW CONE ASSY STD TEA NON METAL W BLU GUARD 5A WC 3358 BREWCONE WIWC 3320 WC 3301 amp WC 3647 OPTNL 5B WC 3399 BREWCONE ASSY TROPICAL TEA NON MTL W YEL GRD 6 WC 58117 COVER TOP BREWER 7 WC 2977 101K 5 FITTING PLASTIC 8 WC 37189 UCM KIT LABEL amp OVERLAY 120V TCTS T 8A WC 729 CONTROL MODULE UCM 220VAC TEA COMBO EXPORT 9 WC 39628 LABEL UCM PANEL W HALF BATCH W O FAUCET 9A WC 390168 LABEL UCM OVERLAY TCT PTT 1 BATCH AFTER 2 2015 10 WC 29025 SPRAYHEAD PURPLE ADVANCE FLOW 10A WC 2942 SPRAYHEAD GRAY OLDER UNITS PARTS LIST ITEM PART N DESCRIPT
4. 1 on 00000 Models Included TCTS T CAUTION Equipment D must be installed to comply with applicable federal state and local plumbing electrical codes having jurisdiction as CAUTION Follow this mim setup procedure before attempting to use this unit Failure to follow these instruc tions can result in injury and or void of warranty as CAUTION DO NOT meer connect the unit to hot water The inlet valve is not rated for hot water IMPORTANT NS After setup run a FULL IMPORTANT brewcycle Place a tea container to catch both hot water from the brewcone and dilution water from spout on the front cover 150 9001 2008 REGISTERED WILBUR CURTIS CO INC Montebello CA 90640 For the latest information go to www wilburcurtis com Tel 800 421 6150 Curtis Co Inc Service Manual TCT amp PTT Important Safeguards Symbols This appliance is designed for commercial use Any servicing other than cleaning and preventive maintenance should be performed by an authorized Wilbur Curtis service technician NOT immerse the unit in water or any other liquid reduce the risk of fire or electric shock do NOT open service panels No user serviceable parts inside Keep hands and other items away from hot surfaces of unit during operation e Never clean with scouring powders bleach or harsh chemicals Symbols WARNINGS To help avoid per
5. 29 WC 53038 TUBE ASSY FLEXIBLE 1 4 FLARE 11 1 8 30 WC 826L VALVE INLET 1 GPM 120V 10W OLDER UNITS 31 WC 895 105 VALVE INLET DUAL 120V 10W 2 GPM X 5 GPM 31A WC 801 VALVE INLET BRASS 50 GPM 120V 10W RU WB OLDER UNITS 31B WC 878 102 VALVE INLET DUAL 220V 10W 1 GPM X 5 GPM DILUTION EXPORT 32 WC 43134 O RING 426 X 9 16 O D X 070 WALL EDPM TCTS 33 WC 889 VALVE DUMP LEFT 120VAC 12W 33A WC 860 VALVE DUMP LEFT 220VAC 12W EXPORT 34 WC 37266 KIT FITTING TANK OVERFLOW 35 WC 37317 KIT STRAIGHT FITTING amp BUSHNG 8MM RECOMMENDED PARTS TO STOCK Illustrated Parts List TCN ITEM PART N DESCRIPTION 1 WC 61436 LID BLACK PLASTIC TCN 2 WC 38471 LABEL FRONT TCN GENERIC 3 WC 1803 FAUCET SPB 4 WC 37260 KIT FAUCET W ADAPTER COMPLETE 5 WC 3707 KIT REPAIR SPB FAUCET 6 WC 1805 SEAT CUP FAUCET S 7 WC 38163 LABEL CURTIS SWP CLR WHT 8 WC 5686 DRIP TRAY OCTAGON STYLE 9 WC 3531 LEG PLASTIC GLIDE TCN 10 WC 3289 HANDLE GASKET RECOMMENDED PARTS TO STOCK Illustrated Parts List TCO OLD UNIT WITH EZ VIEW ITEM PART N DESCRIPTION 1 WC 5683 LID ASSY 2 WC 38471 LABEL FRONT ICED TEA GENERIC 3 WC 3724 KIT EZ VIEW REPLACEMENT OLDER UNITS 4 WC 1803 FAUCET SPB 5 WC 1805 SEAT CUP FAUCET 5 6 WC 3707 KIT REPAIR SPB FAUCET 7 WC 37260 KIT FAUCET W ADAPTER COMPLETE RECOMMENDED PARTS TO STOCK TCT ELECTRI
6. Inc assumes no responsibility for substitute replace ment parts installed on Curtis equipment that have not been purchased from Wilbur Curtis Co Inc The Wilbur Curtis Co Inc will not accept any responsibility if the following conditions are not met The warranty does not cover and is void under the following circumstances 1 Improper operation of equipment The equipment must be used for its designed and intended purpose and function 2 Improper installation of equipment This equipment must be installed by a professional technician and must comply with all local electrical mechanical and plumbing codes 3 Improper voltage Equipment must be installed at the voltage stated on the serial plate supplied with this equipment 4 Improper water supply This includes but is not limited to excessive or low water pressure and inadequate or fluctuating water flow rate 5 Adjustments and cleaning The resetting of safety thermostats and circuit breakers programming and temperature adjustments are the responsibility of the equipment owner The owner is responsible for proper cleaning and regular maintenance of this equipment 6 Damaged in transit Equipment damaged in transit is the responsibility of the freight company and a claim should be made with the carrier 7 Abuse or neglect including failure to periodically clean or remove lime accumulations Manufacturer is not responsible for variation in equipment operation due to excessive lime o
7. Tea by Time Factory set to Full 5 52 Half 2 56 Press to select By pressing lt or gt buttons you can increase and decrease time Press to set minutes and seconds Units with the half batch option the Half Batch brew button is factory set at for half the brew time 2 56 Tea Dilution Delay Factory set to 0 30 Press to Select Press lt or gt buttons to add or decrease time Press to set Tea Dilution Volume Press to Select Display will now show Push START To Begin Press the BREW button and water will flow when desired volume is reached press BREW button again to stop the flow Now the volume has been set Press gt to display subsequent menu features Tea Dilution Time Factory set to Full 4 05 Half 2 02 Press to Select By pressing lt or gt buttons you can increase and decrease time Press to set minutes and seconds Tea Dilution Stir Factory set to ON Press to Select Press lt or gt buttons to toggle between OFF and ON Press to set Tea Pulse Brew Factory set to OFF Press to Select Press lt or gt to select ON OFF or D D is a manual adjust from 1 to 20 pulses with an ON time from 5 to 150 seconds and an OFF time from 5 to 150 seconds Tea Fast Brew Factory set to OFF Press to Select press lt or gt to choose ON or OFF Selecting ON will start hot water spraying in the brewcone first and then 1 minute later the dilution water will start to flow Tea Half
8. 220 F THERMOSTAT TRIAC TOGGLE SW DPST MAN RESET 40A 600V HEATING ELEMENT 254 125 250 40A 277V SEE TABLED Te BLK 14GA gt Li 311 7 275VAC RED 14GA_ 6 4 iS COMMON STUD CHASSIS GROUND 1 0 GPM 10W 220VAC STP YEL INLET VALVE SW 220 GPM 10W 220VAC DILUTION VALVE COMMON STUD CHASSIS GROUND GPM 10W 220VAC STP RED BREW UCM GROUND VALVE D oO O Z oO i lt 4 gt a D PIN ASSIGNMENTS NOT USED N 02 NOT USED N 03 DILUTION VALVE RIGHT N 04 INLET VALVE TANK N 05 BREW VALVE N06 TRIAC GATE NO7 TRIAC 2 ELECTRICAL RATING TABLE N 08 220VAC N 09 TEMP SENSOR TANK TRIAC PIN ASSIGNMENTS N 10 TEMP SENSOR ELEMENT N 11 UCM GROUND WATTS WATTS AMPERES N N 12 WATER LEVEL PROBE 2500Ww 220v 2600 4 NTE NOT USED 3500W 220V 3600 15 NOT USED N 16 220VAC 2 USE THIS DIAGRAM FOR ALL OTHER MODELS WITH ADDED PREFIX LETTERS AND OR DIFFERENT DASH NUMBER ON THEIR PART NUMBERS HAVING THE SAME ELECTRICAL RATINGS NOTAE 220 WATTAGE SEE TABLE AMPERAGE TITLE 1 ALL WIRES SHALL BE 18 AWG PVC COATED 7 LADDER DIAGRAM NOTES UNLESS OTHERWISE SPECIFIED wes wo RENSON L D TCT 30 10 TCT ROUGH IN DRAWING
9. to Select Shows total gallons and total brew cycles on the unit Press ex or Reset Brew Count Total Brew Count Total Press to Select Shows total gallons and total brew cycles on the unit Cannot be reset Cold Brew Lock Factory set to 5 F Press to select lt or gt to select desired setting CBL 5 15 or to set The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point The first setting is within 5 degrees of set point next is within 15 degrees of set point OFF is within 30 degrees of set point for the Ready to Brew message however it will brew at any temperature Master Reset Press to display Are You Sure Then lt for Yes gt for No When Master Reset is used the all of the menu selec tions in the UCM return to factory defaults Service Call Phone number Factory set to 1 800 000 0000 Press to display number and change number or lt to move place and EX to exit when complete This number will be displayed during a Heating system SENSOR ERROR or during a WATER ERROR Access Code Factory set to 1 2 3 4 Press to display number and change number the number be changed 1 to 4 or lt to move place and ex to exit when complete Banner Name Factory set to CURTIS Press to display letters and change letters or lt to move place and EX to exit when complete This feature allows up to 14 letters to be programmed for compan
10. Batch Factory set to On Applies to Models Built after 3 2015 Press to Select Press lt or gt buttons to toggle between OFF and ON Press to set Tea Drip Out Factory set to OFF Press to Select Press lt or gt to adjust time Settings are OFF up to 15 minutes at one minute increments Temperature Factory set to 204 F Press to Select Press lt or gt to increase or decrease setting Temperature range from 170 F to 208 F 2 degree increments Energy Save Mode Factory set to OFF Press to Select lt or gt ON OFF or ON 140 F to set When in ON unit will automatically shut off 4 hours from last brew When feature is OFF unit does not have the energy saving mode In the ON 140 F position temperature goes down to 140 F if unit has not brewed in 4 hours This feature will save energy by maintaining a lower temperature in the tank during periods of non operation On units with the half batch option the half batch brew button may be independently set Continued on Page 4 3 Programming 4 Brew Count Odom Brew Count Total Cold Brew Lock Master Reset Service Call Access Code Banner Name P Maintenance Beeper On Off Quality Timer Display Brew Time Display Messages Model Select Exit Brew Count Odom Press
11. ARTON OR SHIPPING LABEL All in warranty service calls must be performed by an authorized service agent Call the Wilbur Curtis Technical Support Department to find an agent near you Rev V ECN 16087 8 14 14 11 0 2 44 WILBUR CURTIS CO INC 6913 Acco St Montebello CA 90640 5403 USA Phone 800 421 6150 Fax 323 837 2410 Technical Support Phone 800 995 0417 M F 5 30A 4 00P PST E Mail techsupport wilburcurtis com Web Site www wilburcurtis com FOR THE LATEST SPECIFICATION INFORMATION TO WWW WILBURCURTIS COM 14 Printed in U S A 2 2015 3329 5 Rev V
12. CAL SCHEMATIC AUTO RESET TOGGLE SWITCH SPST NON LIT SPST 277VAC 40A on BEMENT POWER CORD 25 125 250VAC BLK 14BLK 14 2207 BLK 14 ail py a2 BLU 14 An WHT 14 BLK K ay Ce C GRN C1 47 275 WHT 14 CHASSIS GROUND 10 GPM 10W 120VAC HEATING TANK YEL SW 120VAC RED GPM 10W 120VAC TANK STUD GROUND UCM GROUND GPM 12W 120VAC STP RED UNIVERSAL CONTROL MODULE PIN ASSIGNMENTS NOT USED DILUTION VALVE INLET VALVE TANK BREW VALVE ELECTRICAL RATING TABLE 1 TRIAC GATE TRIAC 2 HEATING MACHINE POWER CURRENT 120 ELEMENTS watts AMPERES TEMP SENSOR TEMP SENSOR 5 5 10 1600W 165 15 80 GROUND 3 10 TBS 120 1650W 15 84 WATER LEVEL PROBE 5 5 20 1450W NOT USED PTT3 20 5 20 120 1500W 12 5A NOT USED USED 2 USE THIS DIAGRAM FOR ALL OTHER MODELS WITH ADDED PREFIX LETTERS AND OR DIFFERENT DASH NUMBER ON THEIR PART T INLET VALVE DILUTION VALVE BREW VALVE NOT USED TRIAC PIN ASSIGNMENTS HERTZ 50 60 120VAC NEUTRAL WIRES 2W G PHASE 1PH TLE NUMBERS HAVING THE SAME ELECTRICAL RATINGS LADDER DIAGRAM EX TCTS10000 1 ALL WIRES SHALL BE 18 AWG CDATED PART NUMBER NOTES UNLESS OTHERWISE SPECIFIED LD TCT 10 REVISION J TCT ELECTRICAL SCHEMATIC 220V
13. ION 11 WC 66079 SPOUT ASSY DILUTION PLASTIC 11 WC 2965 SPOUT BYPASS ASSEMBLY OLDER UNITS 12 WC 8556 HEAT SINK ASSY DV 13 WC 37255 KIT DUAL VALVE WATER INLET 13A WC 2401 ELBOW 3 8 NPT X 1 4 FLARE PLATED 14 WC 58017 104 COVER FRONT TCTS 14A WC 58021 103 COVER FRONT CENTER WRAP TCTT 14B WC 58101 102 COVER CENTER WRAP PTT3 14 58017 COVER CENTER WRAP 355 TCTDP 35S OLDER UNITS 14D WC 58021 COVER FRONT CENTER WRAP TCTT TCTD 35S OLDER UNITS 15 WC 102 SWITCH TOGGLE SPST 25A 125 250VAC RESISTIVE 15A WC 103 SWITCH TOGGLE DPST 25A 125 250VAC RESISITVE EXPORT 16 WC 3518 LEG GLIDE 3 8 16 STUD SCREW 16A WC 3503 LEG 8 32 STD SCREW BUMPER 17 WC 8531 RAIL BASE TCTD 18 WC 5853 102 COVER TOP HEATING TANK GEN USE 18A WC 5851 COVER TANK W NOTCHES OLDER UNITS 19 WC 43062 GASKET TANK LID 20 WC 6277 TANK COMPLETE 1600W 120V 20A WC 6290 101 COMPLETE TCT PTT CBS W WC 934 01 ELEMENT EXPORT 21 WC 5231 COMPOUND SILICONE 5 OZ 22 WC 5527K KIT PROBE WATER LEVEL O RING amp NUT 23 WC 904 04 ELEMENT HEATING 1 6KW 120V W JAM NUTS 23A WC 934 04 KIT HEATING ELEMENT 2 5KW 220V W JAM NUT WSHR EXPORT 24 WC 4394 SHOCK GUARD HEATING ELEMENT 25 WC 1438 101 SENSOR TEMPERATURE TANK 26 WC 523 THERMOSTAT MANUAL RESET 120 220V 25A 220 F MAX 26A WC 522 THERMOSTAT HI LIMIT HEATER DPST 277V 40A EXPORT 27 WC 5310 TUBING 5 16 ID X 1 8 W SILICONE 28 WC 2707 TEE FLARE x 1 4 x BRASS
14. ON OFF button and the screen will display E F After three seconds CURTIS is displayed FILLING Water will fill the tank approximately 2 3 minutes depending on water flow rate When the proper level is reached CURTIS will appear on the screen HEATING It takes approximately 20 minutes to reach set point temperature of 204 F Control will display when temperature reaches the set point 204 F Unit is now ready to brew BREWING INSTRUCTIONS 1 Brewer should be ON Confirm at rear toggle switch then press ON OFF button Ready to Brew should be dis played on the screen 2 Make sure tea container is correctly placed on the brew deck centered under the brewcone 3 Place a new filter into the 4 Slide the tilled brew cone 6 Select the desired BREW brew basket Pour leaf tea into brew rails button and press to start into the brew cone brewing tea WARNING TO AVOID SCALDING Do not remove the brewcone or coffee container until the UCM screen indicates that the brew cycle has finished To Go Into Programming Turn off dark display by pressing ON OFF button yellow Press and hold BREW button 4 green and then press and release ON OFF button yellow Continue holding BREW button Display will read PROGRAM wait until 20002 5 displayed Enter the 4 digit access code the digits 1 4 corre spond to the buttons see illustration below The default code set at the factory is 1 2 3 4 Then will be displayed
15. ean container to submerge all parts B Immerse in commercial Bar Tabs Sani Tabs sanitizing solution The solution must be warm 75 F Let the parts soak for one minute 8 Air dry all parts that were sanitized 9 After cleaning sanitizing and drying assemble any parts taken from the tea container 10 Clean out airpots with a sponge brush and a mild detergent solution To remove mineral deposits fill liner with vinegar and allow to soak Cleaning intervals for the probe are to be determined by the user or the service tech based on water condi tions The use of water filters or the type of water filter that is being used can impact the service interval Intervals can be from one month to several years however replacing rather than cleaning the probe is preferable WARNING Electric shock hazard Disconnect electrical power before removing access panels CAUTION Scalding and Burn hazard Hot water hot surfaces Allow unit to cool before working 1 Unplug the power cord and shut off the water line 2 Remove the top cover of the tea brewer Locate the heating tank and remove the top cover 3 Drain the tank to a level about 3 below the tip of the probe 4 Allow some time for the heating tank and liquid level probe to cool down before proceeding 5 Clean the tip of the probe using a Scotch Brite scuff pad 6 If a white residue is still visible on the probe remove the probe and soak it in vinegar o
16. ion and growth clean and sanitize tea brewing storage and dispensing equipment at least once a day Regular cleaning of your tea containers will maintain the highest quality iced tea your equipment is capable of producing A proper cleaning is essential in preserving the appearance of the brewer Turn off the tea brewer at the ON OFF button on the front control panel 2 Wipe exterior surfaces with a damp cloth removing spills and debris 3 Slide the brewcone out and clean it Thoroughly soap the sprayhead area with a mild detergent solu tion 4 Wash the brewcone and wire brew basket if applicable Use a soft bristled brush for hard to clean areas Wash both parts with a detergent solution or put these parts through a dishwasher 5 Wash the tea container and top cover Use a detergent solution and a soft bristled brush to clean inside the container Wipe the exterior surfaces with a sponge and detergent solution Rinse thoroughly 6 Clean the faucet assembly Unscrew the handle assembly from the faucet and remove Clean the faucet shank with a gage glass brush circular bristle by pushing the brush through the shank Using the same brush clean the faucet body inlet and outlet Clean the faucet cap and silicone seat cup Thoroughly rinse parts with hot water N After the cleaning place the parts sprayhead brewcone and basket and faucet parts into a sink to be sanitized To sanitize the disassembled parts A Use a cl
17. nsor Err To reset the control panel and return to normal operation press the button for 5 seconds 13 Product Warranty Information The Wilbur Curtis Co Inc certifies that its products are free from defects in material and workmanship under normal use The following limited warranties and conditions apply 3 Years Parts and Labor from Original Date of Purchase on digital control boards 2 Years Parts from Original Date of Purchase on all other electrical components fittings and tubing 1 Year Labor from Original Date of Purchase on all electrical components fittings and tubing Additionally the Wilbur Curtis Co Inc warrants its Grinding Burrs for Forty 40 months from date of purchase or 40 000 pounds of coffee which ever comes first Stainless Steel components are warranted for two 2 years from date of purchase against leaking or pitting and replacement parts are warranted for ninety 90 days from date of purchase or for the remainder of the limited warranty period of the equipment in which the component is installed All in warranty service calls must have prior authorization For Authorization call the Technical Support Department at 1 800 995 0417 Effective date of this policy is April 1 2003 Additional conditions may apply Go to www wilburcurtis com to view the full product warranty information CONDITIONS amp EXCEPTIONS The warranty covers original equipment at time of purchase only The Wilbur Curtis Co
18. ow prevention device may be required between the brewer and the water supply 3 Water pipe connections and fixtures directly connected to a potable water supply shall be sized installed and maintained in accordance with federal state and local codes 1 A 1 4 Flare has been supplied for water line connection Use tubing sized sufficiently to provide 7 GPM preferred flow rate is 1gpm 2 Connect the unit to an appropriate electrical power circuit 3 the toggle STANDBY ON switch behind the unit The heating tank will start to fill When the water level in the tank rises to the correct volume the heating element will energize automatically With G3 tea brewers there is no danger of element burnout caused by an empty tank 4 The heating tank will require 20 to 30 minutes to reach operating temperature 204 F This is indicated when READY TO BREW is displayed on the screen 5 Important Run one full brewcycle to purge the water lines and valves of air Five seconds of dilution water at the beginning of each brewcycle is normal operation FOR THE LATEST SPECIFICATIONS AND INFORMATION TO WWW WILBURCURTIS COM 1 TCT amp Your Curtis Generation 3 Brewer is Factory Pre Set for Optimum Performance After connection to water and power the rear toggle switch must be on You will hear a beep sound indicating power is available to the controller CURTIS lt gt The control displays Press
19. r a scale removing chemical Repeat this step until the probe is clean Tank Temperature Check Turn on brewer at the control panel ON OFF button Press and hold the button arrow for 5 seconds The water temperature in the heating tank will be displayed on the screen Press to exit This feature only applies to brewers using the control module UCM part number WC 786 Error Message With the G3 Gold Cup Series brewers there are three error messages that can appear on the screen to advise the user of a malfunction If one of these error messages appear the brewer will lock up and stop functioning until the error is corrected An error message will occur under the following conditions 800 000 000 1 Water level fill error or overflow This error message occurs when the inlet valve solenoid has been on for more 7 than 10 minutes This error message also occurs when the valve is refilling the tank during a brew cycle for Water Level Err more than 1 minutes 2 Water temperature control system error An open probe or a break in the temperature control circuit is detected 800 000 000 This error message indicates there is an overheating problem The sensor is reading that temperature in the Over Temp Error heating tank has risen above 210 F 3 Usually the screen will display a service call phone number malfunction is 800 000 000 rected the error message must be cleared Se
20. r local water conditions The equipment must be maintained according to the manufacturer s recommendations 8 Replacement of items subject to normal use and wear This shall include but is not limited to light bulbs shear disks 0 rings gaskets silicone tube canister assemblies whipper chambers and plates mixing bowls agitation assemblies and whipper propellers 9 Repairs and or Replacements are subject our decision that the workmanship or parts were faulty and the defects showed up under normal use All labor shall be performed during regular working hours Overtime charges are the responsibility of the owner Charges incurred by delays waiting time or operating restrictions that hinder the service technician s ability to perform service is the responsibility of the owner of the equipment This includes institutional and correctional facilities The Wilbur Curtis Co Inc will allow up to 100 miles round trip per in warranty service call RETURN MERCHANDISE AUTHORIZATION All claims under this warranty must be submitted to the Wilbur Curtis Co Inc Technical Support Department prior to performing any repair work or return of this equipment to the factory All returned equipment must be repackaged properly in the original carton No units will be accepted if they are damaged in transit due to improper packaging NO UNITS OR PARTS WILL BE ACCEPTED WITHOUT A RETURN MERCHANDISE AUTHORIZATION RMA RMA NUMBER MUST BE MARKED ON THE C
21. sonal injury Important Notes Cautions from the factory Sanitation Requirements The Curtis G3 Brewer is Factory Pre Set and Ready to Go Right from the Box Following are the Factory Settings for the G3 Iced Tea Brewer Brew Temperature 204 F Brew Volume Set to dispensing vessel requirements Generally there will never be a reason to change the G3 Gold Cup Series default settings However should you need to make slight adjustments to meet your brewing needs programming instructions are provided later in this manual System Requirements Water Source 20 90 PSI Minimum flow rate of gpm 1 gpm preferred flow rate Electrical See electrical schematic page 6 SETUP STEPS The unit should be level left to right and front to back and located on a secure counter top Connect water line from the water filter to the brewer NOTE A water filtration system must be used to help maintain trouble free operation Air must Wedd be purged from the cartridge prior to connection to equipment In areas with extremely hard water we highly recommend the use of a Curtis approved water filter For our full line of filters please log on to www wilburcurtis com NSF International requires the following water connection 1 A quick disconnect or additional coiled tubing at least 2x the depth of the unit so that the machine can be moved for cleaning underneath 2 some areas an approved backfl
22. y name or regional name Programming all blanks disables Banner Name If programmed Banner Name is displayed every 5 sec on and off P Maintenance Factory set to OFF Press to Select Set gallons brewed to indicate P Maintenance Press lt or gt to adjust from Off to 3000 gallons Press to exit Beeper On Off Factory set to ON Press to display ON or OFF Pressing either lt or gt toggles between on and off to set When ON this feature allows you to hear a short beep each time a button is pressed Quality Timer Factory set to OFF Press to Select By pressing lt or gt buttons you can increase and decrease time Setting range is from 0 to 10 hours in 1 hour increments Press to set Expired time indicated by audio alarm and flashing Quality Timer Display Brew Time Factory set to ON Press to Select Pressing lt or gt toggles between ON and OFF Display Messages Factory set to ON Press to display ON or OFF Pressing either lt or gt toggles between on and off This feature allows the operator to select the message Rinse Server Before Brewing This will be displayed any time the unit is not brewing Model Select Factory set to TEA IC 1BATCH Press to Select Pressing lt or gt toggles between 1 Half Batch and 3 Batch For units built after 3 2015 the selec tions are TEA IC 1BATCH TEA IC 2BATCH TEA IC 3BATCH TEA IC 4BATCH TEA SWEET DUAL DILUTION DUAL SWEET COMBO

Download Pdf Manuals

image

Related Search