Contents
1. Are the incoming water faucets turned on No turn water faucets on Yes go to step 3 Is the incoming water pressure above 30 psi No have customer correct pressure problem Yes check for kinked or blocked incoming water hoses clean incoming water screens If problem still remains replace the water inlet valve assembly Does the fill water continue to enter the washer Yes go to step 5 no go to step 6 Remove power from washer Did the water fill stop Yes go to step 6 No replace the inlet valve assembly For Better models check the electronic pressure sensor For Good models check the pressure switch Pressure sensor checks good Go to step 7 Pressure sensor checks incorrect Replace pressure sensor Replace the Main Control Board Water leak in tub or air leak in air bell Is the washer leakingwater Yes Correct water leak No Go to step 2 Is there a leak in the air bell system Yes Correct the leak problem No Go to step 3 For Better models check the electronic pressure sensor For Good models check the pressure switch Defective Replace pressure sensor switch Good Go to step 4 Replace the Main Control Board Is the dispenser drawer closed No close the drawer Yes go Reed Switch to step 2 Remove the drawer and check the magnet Magnet missing or defective replace the magnet Magnet good Go to step 3 Open the console and check the reed switch De
2. FRIGIDAIRE WY White Westinghouse Gibson Kelvinator TAPPAN 2010 Electrolux Home Products Inc 10200 David Taylor Drive Charlotte NC 28262 Publication 5995588729 February 2011 Section 1 Basic Information Safe Servicing Practices Avoid personal injury and or property damage by observing important Safe Servicing Practices Following are some limited examples of safe practices 1 DO NOT attempt a product repair if you have any doubts as to your ability to complete the repair in a safe and satisfactory manner 2 Always Use The Correct Replacement Parts as indicated in the parts documentation Substitutions may defeat compliance with Safety Standards Set For Home Appliances 3 Before servicing or moving an appliance e Remove power cord from the electrical outlet trip circuit breaker to the OFF position or remove fuse 4 Never interfere with the proper operation of any safety device 5 Use ONLY REPLACEMENT PARTS CATALOGED FOR THIS APPLIANCE Substitutions may defeat compliance with Safety Standards Set For Home Appliances 6 GROUNDING The standard color coding for safety ground wires is GREEN or GREEN with YELLOW STRIPES Ground leads are not to be used as current carrying conductors It is EXTREMELY important that the service technician reestablish all safety grounds prior to completion of service Failure to do so will create a hazard 7 Prior to returning the product to service ensure that e All electrical
3. If error still exist replace Main Control Board UL test mode Displayed in relay test mode when UL test is activated Water Test Mode To activate water test mode press and hold Start Cance and heating option High Temp Wash Sanitize Air Dry or No Heat Dry depending on model for 3 seconds To advance through test s press Start Cancel If component tested fails error code will be displayed in digital display Test Description Components Energized And Being Monitored Fill and dispenser 60 sec Water valve and dispenser energized fan damper is monitored washing and sensing LED should be lit Fill 27 sec Water valve energized turbidity sensor is monitored washing and sensing LED should be lit Wash and heat 45 sec Circulation motor and heater energized hall sensor is monitored washing and sensing LED should be lit Pause 0 4 Sec Heater energized washing sensing and rinse LED should be lit Wash and heat 75 sec Circulation motor and heater energized rinse LED should be lit Wash heat and dispenser 60 sec Circulation motor heater and dispenser energized rinse LED should be lit thermistor is monitored Drain motor and fan unit energized fan speed is monitored Dry 90 sec Drain motor and fan unit energized rinse aid level is monitored drying LED should be lit TOTAL TIME 447 Sec Sanitized and clean LED should be lit Section 7 Dishwasher Electrolux Dishwasher Error C
4. toggle the components between on and off Key To Toggle Component On And Off Description FAVORITE Heater Unit must have water before toggling on the heater Wash Pump Water Valve QUICK Drain Valve Automatically cycle between opened and closed RINSE Clean light where applicable SANITIZE Lower fan 3 second delay and then upper fan and damper Exit Relay Test Mode 1 Press Start Cancel key to disable relay test outputs 2 Press and hold the Hi Temp key for a minimum of 5 seconds to reset the dishwasher Section 8 Refrigerators French Door And I ceman Error Codes Error i i Code Description Solution Freezer sensor open in freezer display Check wiring between thermistor and board If correct replace thermistor Freezer sensor shorted in freezer Check wiring between thermistor and board If correct replace display thermistor Fresh food sensor open in fresh food Check wiring between thermistor and board If correct replace display thermistor Fresh food sensor shorted in fresh Check wiring between thermistor and board If correct replace food display thermistor Evaporator fan circuit failure Check wiring between evaporator fan and Main Control Board Check for 12VDC to fan between red and brown wires Check for variant voltage depending on high or low speed between yellow and brown If correct replace evaporator fan If error code still exist replace Main Control Board Communication Err
5. 6 Follow the on screen directions 3 12 Description Runaway temperature Shorted keypad Bad micro identification Bad EEPROM identification checksum error Display tail missing not connected Signal loss between Oven Relay Board and EOC Communication failure between EOC and ESEC system Communtication failure between the EOC and ESEC electric models only Communication failure with Mini Oven Control Open probe connection Section 4 Range Solution Check RTD sensor probe and replace if necessary If oven is overheating disconnect power If oven continues to overheat when the power is reapplied replace EOC Severe overheating may require the entire oven to be replaced should damage be extensive F11 12 amp 13 disconnect power wait 30 seconds and reapply power If fault returns upon power up replace EOC Check connection between Main Control Board and keypad If correct replace Main Control Baord If problem persist replace keypad Test the harness and connections from EOC connector P16 to Oven Relay Board J2 Replace the Oven Relay Board Replace the EOC Test harness connections P4 EOC and P11 Surface Element Control Board If harness checks correct failure can be caused by faulty UIB Surface Element Control Board or EOC Check harness and connectors from the EOC to Mini Oven Control Board Check for 15VDC to Mini Oven Control red and gray wires If harness and vol
6. Control Board and User Interface Board Check wiring between Main Control Board and User Interface Board If correct replace User Interface Board If error still exist replace Main Control Board Main control board Failure in Main Control Board relay Replace Main Control Board relay error Main Control Board timed out before receiving status of drain Drain valve valve Check wiring between Main Control Board and drain valve If correct replace drain valve If error still exist replace Main Control Board E12 Drain valve Drain valve is open or running when it should be closed or off Replace drain valve System failure Lost control state of the machine Replace Main Control Board Section 7 Dishwasher Relay Test Mode models EWDW6505 For EWDW6505 models to enable the relay test mode perform the following steps in sequence If a wash cycle is running press Start Cancel key to cancel operation and allow to drain Press Select Options Press and hold Set for a minimum of 5 seconds to reset the dishwasher Simultaneously press and hold the Delay Time and Wash Cycles keys until water serv is displayed Press lt to switch to relay test mode and then press Set key to enable Use lt gt keys to cycle through the component menu N DOD ow A WN Be Once the desired component is selected press Set key to toggle between on and off the door must be closed to energize the component The Wash Cycles op
7. LIN error communication filter Verify cable between Filter Board X58 and Generator Control service section incorrectly this is an Board X10 Verify the heat sink thermal limiter resistor to error detected between the Filter Board be approximately 0 ohms Replace Filter Control Board on the and the Power Boards Induction Module Replace Generator Control Board on the Induction Module Section 5 Induction Cooktop Error a i Code Description Solution Mains voltage signal invalidly phase 1 Verify AC input voltage at the cooktop input Verify AC main input undervoltage or optocoupler defective cables screws and jumpers Verify the fuse resistance to be this is an indication that one phase is approximately 0 ohms on the Induction Module Replace the Filter wrong The other phase will still work Board on the Induction Module LIN error communication touch control Replace the Control Board left board Replace the Filter Board filter incorrectly on the Induction Module Replace the Generator Control Board on the Induction Module a Heat sink temperature sensor break Replace the Generator Control Board on the Induction Module Temperature sensor defect Test coil RTD for approximately 1k ohms at room temperature Replace coil if resistance is correct Replace Power Generator Control Board amp NOTE If multiple changing error codes are displayed check for disconnected wires or cables 5 6 Description If the wa
8. Sensor temp is over 65 C or below 50 C Displaying a defect when the R Defrost completes automatically in 50 minutes Displaying a defect when the Ambient Temperature Sensor temp is over 65 C or below 50 C Displaying a defect when the F Sensor temp is over 65 C or below 50 C Displaying a defect when the temp sensing of the F Defrost Sensor is over 6 5 C or below 50 C Displaying a defect when the F G signals generated during operation of FAN Motor are not input Displaying a defect when the F G signals generated during operation of FAN Motor are not input Displaying a defect when F Defrost completes automatically in 50 minutes Displaying a defect when errors occur between main MICOM and load MICOM Displaying a defect when errors occur between main MICOM and panel MICOM Communication error with PLC modem When itis not connected with PLC modem Note PLC Communication modem will be applied optionally So even if the appliance which dogs not apply PLC displays this error digit It is not defect 8 15 Section 9 Wine Cooler Beverage Center Wine Cooler Beverage Center Error Codes Error i Code Description Solution eo Primary sensor open Check wiring to primary sensor If correct replace sensor Primary sensor shorted Check wiring to primary sensor If correct replace sensor E2 Evaporator sensor open Check wiring to evaporator sensor If correct replace sens
9. door lock and Main Control Board If good replace the door lock If problem is not corrected replace the Main Control Board Section 2 Washing Machines Error o i Code Description Solution Bad signal from tacho generator Disconnect the plug from the drive motor and measure the resistance of pins 4 and 5 in the motor If reading is between 105 and 130 ohms replace the Speed Control Board If the meter reads outside 105 and 130 ohms replace the motor Low voltage to Speed Control Board Check the wiring between the Main Control Board and the Speed Control Board If good replace the Speed Control Board Over speed 1 Remove the belt from the motor and spin the motor pulley Does the motor spin free No replace the motor Yes go to step 2 Spin the tub pulley Does the tub spin free No check the tub bearings Yes go to step 3 Disconnect the plug from the drive motor and measure the resistance between pins 4 and 5 in the motor If the meter reads other than between 105 and 130 ohms replace the motor If the reading is between 105 and 130 ohms go to step 4 4 Disconnect the plug from the motor and measure the resistance of the windings Pin 1 to 2 pin 1 to 3 pin 2 to 3 all readings should be between 3 and 6 ohms If readings are correct replace the Speed Control Board If readings are incorrect replace the motor Motor overheating Remove the belt from the motor and spin the motor pulley Does the motor
10. ect and Cance buttons simultaneously for 6 seconds to reset the control The buzzer will sound 1 time and res will be shown briefly in the display Immediately after rotate cycle selector knob 5 turns counter clockwise to the second position from the bottom Press and hold the Options and Cancel buttons simultaneously for 6 seconds The control will enter test mode the buzzer will sound 3 times and all LED S will rapidly flash Rotate the cycle selector knob 2 turns counterclockwise The error code will appear in the digit display To move on to the next code press the Options button To clear an error code press the Se ect button Code will be cleared when mode is exited To exit this mode simultaneously press and hold the Se ect and Cance buttons for 6 seconds 3 7 Section 3 Dryers Affinity Diagnostic Mode newer models 1 Press the Cance button to enter standby mode and enable diagnostic entry 2 Within 10 seconds after pressing Cancel press any button except for Cance to wake up the control 3 Within 5 seconds of wake up turn the selector knob to the far eft cycle and press and hold the Cance and the center button under the display simultaneously for 3 seconds to enter the diagnostic mode amp NOTE To save time at wake up the Welcome screen can be bypassed by turning the selector knob 4 Upon entering diagnostic mode all lights should flash on and off 5 The following steps can be cycled through by
11. no motor wire Ejection restoration and horizontal position failure more than 3 times Fresh Sensor Housing slip out Contact Failure Wire Cut Wire Short Defective Fresh Sensor R Heater Housing slip out Contact Failure Wire Cut Wire Short Defective R Heater Defective Defrost Temp Fuse Ambient Temperature Sensor Housing slip out Contact Failure Wire Cut Wire Short Defective Ambient Temperature Sensor Sensor Housing slip out from the F Room Contact Failure Wire Cut Wire Short Defective F Sensor F Defrost Sensor slip out from the evaporator of the F Room Contact Failure Wire Cut Wire Short Defective Sensor Errors in operation of F FAN Motor Contact failure of feedback signal line no motor wire etc Errors in operation of C FAN Motor Contact failure of feedback signal line no motor wire F Heater Housing slip out contact failure wire cut wire short Defective F Heater Defective Defrost Temp Fuse Defective Main PCB Pattern and MICOM Defective PCB Housingslip out Contact Failure Wire Cut Wire Short Defective MICOM Displaying a defect when the I M Sensor temp is over 65 C or below 50 C Displaying a defect when the R Sensor temp is over 65 C or below 50 C Displaying a defect when the R Defrost Sensor temp is over 65 C or below 50 C Displaying a defect when F G signals generated during operation of FAN Motor are not input Displaying a defect when the Fresh
12. off LED display test illuminates display LED s Exit service mode hold left temperature Up key for 5 seconds to exit service mode Evaporator sensor will display E1 Normal E2 Open E3 Shorted Section 9 Wine Cooler Beverage Center Sabbath Mode Press and hold the Vacation Mode key for 5 seconds The temperature display will show SB While in Sabbath mode the alarm lights will illuminate but will not be accompanied by audible tones 9 2 Air Conditioner Error Codes Error See Code Description Ambient Thermistor error Evaporator Thermistor error Heater Thermistor error Section 10 Air Conditioners Solution Check wiring between Main Control Board and Thermistor If correct replace Thermistor If error still exists replace Main Control Board Check wiring between Main Control Board and Thermistor If correct replace Thermistor If error still exists replace Main Control Board Check wiring between Main Control Board and Thermistor If correct replace Thermistor If error still exists replace Main Control Board 10 1
13. supply voltage too low Have the power company check the frequency and voltage of the incoming power If correct for error code E5C replace the Speed Control Board If correct for error codes EA1 EA2 EA3 EAS EAE or EA5 replace the Main Control Board Main voltage sensing failure Have the power company check the frequency and voltage of the incoming power If correct for error code E5C replace the Speed Control Board If correct for error codes EA1 EA2 EA3 EAS EAE or EA5 replace the Main Control Board Line safe relay sensing failure Have the power company check the frequency and voltage of the incoming power If correct for error code E5C replace the Speed Control Board If correct for error codes EA1 EA2 EA3 EAS EAE or EA5 replace the Main Control Board Power supply frequency out of limits Have the power company check the frequency and voltage of the incoming power If correct for error code E5C replace the Speed Control Board If correct for error codes EA1 EA2 EA3 EAS EAE or EA5 replace the Main Control Board E93 E94 E95 E97 E98 ESF EA1 EA2 EA3 EA5 EAE Bl E Incoming power frequency out of limits Have the power company check the frequency of the incoming power If correct replace the Main Control Board Section 2 Washing Machines Error o i Code Description Solution Incoming line voltage above 130VAC Check voltage at the outlet If below 130VAC replace the Main Control Board Inc
14. the Start Pause button then the Cance button 4 Wake the unit up again immediately and simultaneously press and hold the My Favorites and Eco Friendly buttons for 5 seconds The display will show install cycle with the estimated time of cycle completion 5 Press the Start Pause button to begin the cycle Installation Cycle will test for electronic issues wiring issues and water flow issues At cycle completion the display will show instal pass or prompt an action during the cycle such as call service no water or check hoses Correct the action and repeat the cycle for proper installation Washer will exit the install cycle and return to normal operation the next time the knob is turned 1 x 4 3 4 display models 1 The machine will first wake up on setting up the unit to display Janguage selection Press next to display the install cycle You can run it now if you choose If you don t want to run it immediately you can access the install cycle through the pref menu in the option window Press the Select key once you scroll to the pref selection Then scrolll through this menu until you get to the install cycle Press the Se ect key then follow the instructions remove all articles from the washer drum You can also get to this cycle by performing a full reset of factory settings To Clear The Last Stored Error Codes Press the Cancel button to enter standby mode and enable diagnostic entry Within 10 seconds after pressing Ca
15. thermistor If problem still exist replace Main Control Board 2 Infreezer Freezer thermistor open Check wiring between freezer thermistor and Main Control Board window If correct replace thermistor If problem still exist replace Main Control Board 3 In freezer Freezer thermistor shorted Check wiring between freezer thermistor and Main Control Board window If correct replace thermistor If problem still exist replace Main Control Board Damper failure Check wiring between damper and Main Control Board If correct replace damper If problem still exist replace Main Control Board Defrost Activation Mode Brand Series Activation Sequence Electrolux S S Hold Fresh Food And For 6 Seconds Df shows in display French Door Hold Fresh Food And For 6 Seconds Df shows in display Ice Man Hold Fresh Food And For 6 Seconds Df shows in display Frigidaire S S Manual Control Push light switch 5 times within 6 seconds Frigidaire S S Electronic Control Hold freezer Up while pushing fresh food Down 5 times in 6 seconds Up and Down arrows on Frigidaire models instead of and respectively Section 8 Refrigerators Freezer Defrost Mode Brand Series Activation Sequence Turn control to 2 and hold Up and Down buttons 5 seconds Freezer With Control On Turn control to 2 and hold Up and Down buttons 5 seconds Evaporator Cover Deluxe Control Half Moon Press and hold Qui
16. to the cook place 4 rear right induction housing Element temperature sensor break i i istor value is not cook place 5 front right 2 Replace element if the temperature sensor resistor value is no approximately 1000 ohms at room temperature Verify cooktop ventilation is correct airway and fan relay board Verify if the cooktop is correctly assembled Change the Relay Board Element temperature sensor too hot oe Verify cooktop ventilation is correct airway and fan place 4 rear right Verify element temperature sensor is correctly connected to the Element temperature sensor too hot f Induction Module place 5 front right Replace element if the temperature sensor resistor value is not correct SS e Internal Hra error sync center Test cables and connections on center Generator Control Board cooking zone single tC 73 Seeeror33 o See error33 33 See error 33 error 33 Section 5 Induction Cooktop Code Description Solution Internal generator error Check cable between Filter Board X13 and Generator Control communication 3 Zones Induction Board X10 Replace the Filter Control Board in the 3 zones Induction Module Replace Generator Control Board in the 3 zones Induction Module Communication error in the 3 cook Verify all communication cables between User Interface Board Zones Induction Module for the center and both Induction Generator Modules Replace the Filter Contr
17. turning the selector knob clockwise Diagnostic Test Sequence Test Activated Component Operator Check LCD Row LCD Digits Electric Gas Motor Counter Clockwise Check motor function Look for drum Motor CCW CCW rotation in counter clockwise direction 2 Contact Sensor Check moisture reading Place fingers Moist Bars 1111 If contact across contact sensor and look for sensor open digit display to change from 1111 to circuit 8888 if 8888 contact sensor short circuited Motor Clockwise CW Check motor function Look for drum Motor CW rotation in clockwise direction Lights buttons Lights buttons Check all buttons and lights Press all Button ID Number Test motor Test motor buttons and check for beep and CW CW igniter button ID number in digit display Check to see that all lights function Motor CW Motor CW Check motor and heater function HEAT1 NTC1 Outlet heater 1 heater Check outlet control thermistor value control thermistor in digit display value Degrees F Section 3 Dryers Diagnostic Test Sequence continued Test Activated Component Operator Check LCD Row LCD Digits Electric Gas Motor CW Motor CW Check motor and heater function HEAT2 NTC2_ Inlet control heater 1 heater Check inlet control thermistor value thermistor value heater 2 in digit display Degrees F Motor CW Motor CW Check motor and heater function HEAT3 NTC1 Outlet control heater 1 heater Check outlet control thermist
18. will not be affected The user interface will exit diagnostics mode and automatically restart in normal power up operations Exiting Diagnostic Mode Press and hold the Up and Down keys simultaneously for 3 seconds or more The buzzer will beep at the end of 3 seconds 8 11 Section 8 Refrigerators Diagnostic Electrolux 42 built in refrigerator Service Diagnostics Diagnostic Mode 1 To enter the diagnostic mode the temperature display must be lit up If the temperature display is not lit press any pad on the overlay ADJUST TEMPERATURE es 77 Fermicerator 37 F 1S RECOMMENDED Oa O F 1S FECOMMENDED ICE OISPENSER WATER CRIED cLom axr CEC DOOR ALARN 2 Press the 2 COLDER and 2 WARMER pads simultaneously for three seconds The FREEZER and REFRIGERATOR displays will change to 0 0 Petrie Manises Press Simultaneously 3 To select a test mode a Enter a numeric value see Test Mode Chart on the FREEZER display using the COLDER or WARMER pad Note The COLDER pad decreases the numeric value The WARMER pad increases the numeric value b Enter a numeric value see Test Mode Chart on the REFRIGERATOR display using the COLDER or WARMER pad 4 Once the displays indicate a test mode press any pad 8 12 on the temperature board overlay other than the COLDER or WARMER pads to enter that mode Note A test mode must be selected within 30 sec
19. Board replace the pressure sensor If this does not correct the problem replace the Main Control Board Pressure sensor calibration problem Inspect the wiring between the pressure sensor and the Main Control Board Defective wiring correct wiring Good wiring replace the pressure sensor If this does not correct the problem replace the Main Control Board Is the water level above 4 5 inches Yes go to step 2 No go Better models pressure sensor to step 4 indicates water overfill Does the water enter the washer continuously Yes go to step 3 No replace the Main Control Board Remove power from the washer Does the water stop coming in No replace water valve assembly Yes check wiring to valve assembly for shorts If wiring is good replace the Main Control Board Replace the pressure sensor switch Did this correct the problem Yes problem solved No replace the Main Control Board Main Control Board problem Replace Main Control Board Section 2 Washing Machines Code Description Solution Air trap clogged Is the water level above 4 5 inches Yes go to step 2 No go to step 4 Does the water enter the washer continuously Yes go to step 3 No check air trap for clog If not replace the Main Control Board Remove power from the washer Does the water stop coming in No replace the water valve assembly Yes check the wiring to valve assembly for shorts If wiring is good replace the M
20. GROUND OPEN CIRCUIT INFINITE RESISTANCE Oven Calibration Press and hold Bake upper oven or lower oven depending on model for 10 seconds The current calibration offset temperature adjustment should appear in the temperature display Use the number keys Up and Down arrows depending on model to enter the desired amount of adjustment Up to 35 and down to 35 Press Self Clean to change the sign of the adjustment to a if necessary A positive adjustment will not display a sign Once the desired adjustment 35 to 35 f has been entered press the Start pad to accept the change or the Cance key pad to reject the change On some models to calibrate oven temperature press Bake Set temperature to 550 Press and hold Bake for 10 seconds Description Key sensor for cook place 3 center center board Key sensor for cook place 3 center center board Key sensor for timer right board Section 5 Induction Cooktop Solution Test flex cable between left board and center board Change center board Change left board Test flex cable between boards Change right board Change center board on 36 models only Change left board Warm key sensor for keep warm Change left board left baord Key sensor for cook place 2 right Change left board position left baord Key sensor for timer right board Test flex cable between boards Ch
21. On a small number of washers with serial number prefix XC4 if the previous procedure does not preform as specified follow the option below Follow all previous steps but instead of pressing Start and Pause Cance buttons press and hold Options and Pause Cancel buttons The control will pause for 2 seconds then repeat the code as long as the two buttons are pressed and held A letter appearing in the code stands for a number higher than nine A 10 B 11 C 12 D 13 E 14 F 15 Example code F1 the first digit would be 15 and the second would be 1 If this code would appear on a washer in the Good model line the five indicator lights would blink fifteen times and the Start indicator light would blink once Troubleshoot problem by using charts on the following pages 2 12 Section 2 Washing Machines Frigidaire Diagnostic Mode continued Exiting Diagnostic Mode There are two options for exiting the diagnostic test mode and returning the washer to normal operation a Unplug the power cord wait 5 8 seconds then reconnect the power cord or b Turn the program knob clockwise 2 or 3 clicks after the start position Press Options and Pause Cance buttons simultaneously for a few seconds until wash cycle LED s appear If a situation arises where you cannot exit the diagnostic mode as described above and the bank of 5 LED s on the right end remain on regardless of program knob position a combination of pushed buttons may have caused the contr
22. Standard compressor test only on Press On Off key to activate test and turn on compressor models with standard compressor Defrost heater test Press On Off key to activate defrost heater Fresh food lighting test Press On Off key to turn on fresh food lighting freezer door depending on model should stop auger rotation VCC condensor fan test Press On Off key to activate condenser fan Perfect temp drawer test Press On Off key to activate perfect temp drawer VCC compressor test on VCC models Press On Off key to activate compressor only Evaporator fan test Press On Off key to activate evaporator fan motor Damper test Press On Off key to activate damper Op should display when damper is open and c should display when damper is closed Ice door test Press On Off key to activate ice door solenoid When door is open display should display Op When door is closed display should display c Activate manually or by On Off key Fresh food door switch test Open fresh food door s display will display Op Close fresh food door s display should display cl Freezer door switch test Open freezer door display will display Op Close freezer door display should display cl Section 8 Refrigerators Electrolux and Iceman Service Test Mode continued Test Number Description Resolution Defrost limit switch test defrost bi When bi metal is open display should display Op When bi metal metal is closed display should display c
23. a 6 O Totma O Ettestmode o a Cai ja Note 1 Showroom Mode In the showroom mode the compressor and fans do not operate The fresh food and freezer lights operate as normal ON when door is opened The dispenser and dispenser display operate as normal Temperature set points can be changed Press the DISPLAY TEMP pad to display the actual cabinet temperature To exit the showroom mode cycle power OFF or enter test mode 1 5 to reset the unit Note The showroom mode can also be entered outside of the service mode by simultaneously pressing the COLDER pad on the FREEZER display and the WARMER pad on the REFRIGERATOR display for 3 seconds the display must be lit before pressing the pads Press Simultaneously Note 2 HMI Self Test Once the HMI self test is started all of the LEDs and seven segment LEDs will illuminate The COLDER pad turns off the seven segment LEDs and the WARMER pad turns off the SET LED for both the FREEZER and REFRIGERATOR displays When all the available LEDs have been turned off for that specifi c temperature board the COLDER and WARMER pads on the REFRIGERATOR display must be held simultaneously for 3 seconds to exit the HMI self test This can be done any time during the test Note 3 Control and Sensor System Self Test 8 13 Section 8 Refrigerators Diagnostic Electrolux 42 built in refrigerator continued This test does a check on all thermistors fans and defrost circuits The the
24. ain Control Board Replace the pressure sensor switch Did this correct the problem Yes problem solved No replace the Main Control Board Main Control Board thinks the door Is the loading door closed No close the door Yes go to step switch is open 2 Disconnect the plug from J2 on the Main Control Board and check for continuity between the pins in the plug Open check the door strike If good replace the door switch assembly Closed replace the Main Control Board Door remains locked after cycle is Remove power from the washer Wait one minute Can you complete open the door Yes replace the Main Control Board No replace the door switch assembly Note you may have to break the door strike to do this Main Control Board problem Replace Main Control Board Main Control Board problem Replace Main Control Board Main Control Board problem Replace Main Control Board Main Control Board problem Replace Main Control Board Board thinks the door PTC circuit is Remove the door lock assembly and measure the resistance of open in spin the PTC Shorted or open defective door lock assembly Reads around 1500 ohms defective Main Control Board Door incongruence between door 1 Is the loading door closed No close the door Yes go to step line and door sense 2 2 Can you hear the lock attempt to close Yes check the door strike If good replace the door switch No go to step 3 3 Check the wire connection between
25. am knob To start the test On non digital display models turn the program knob to the start position Drain Spin On digital display models turn the program knob to the start position Touch Up amp NOTE If the model has a timer dial that can be Rotated 360 turn the program knob to the start position Drain Spin Press Pause Cancel to turn off LED s Within 5 seconds press and hold the Option and Pause Cancel buttons until LED s start sequentially chasing then release buttons 1 All the LED s will sequentially light Pressing a button below a light cluster will light all the LED s in that cluster at one time to confirm functionality 2 Turn the program knob 1 click clockwise from the start position The hot water solenoid will activate and hot water should enter through the detergent compartment 3 Turn the program knob 2 clicks from the start position The bleach water solenoid will activate and cold water should enter through the bleach compartment 4 Turn the program knob 3 clicks from the start position The bleach and the wash water solenoids will activate and cold water should enter through the softener compartment 5 Turn the program knob 4 clicks from the start position The door lock solenoid will activate 6 Turn the program knob 5 clicks from the start position The door lock solenoid will deactivate and the loading door can be opened 7 Turn the program knob 6 clicks from the st
26. ange right board Change center board on 36 models only Change left board Zone Power key sensor for cook place 1 3 center center board Test flex cable between left board and center board Change center board Change left board Zone Power key sensor for cook place 4 left position right board Key sensor for cook place 4 left position right board Test flex cable between boards Change right board Change center board on 36 models only Change left board Key sensor for cook place 5 right position right board Zone power key sensor for Change left board cook place 1 left position left board Key sensor for cook place 4 left 1 position right board 2 Key sensor for cook place 5 right 3 position right board On Off timer right board 4 Test flex cable between boards Change right board Change center board on 36 models only Change left board Section 5 Induction Cooktop Error Code Description Lock key sensor for control lock Size key sensor for cook place 1 left position left board Zone Power key sensor for cook place 5 right position right board Key sensor for cook place 2 right position left board Zone Power key sensor for cook place 2 right position left board Key sensor for cook place 1 left position left board Key sensor for cook place 1 left positi
27. art position The washer will fill and tumble 8 Turn the program knob 7 clicks from the start position The washer will fill and spin leakage test 9 Turn the program knob 8 clicks from the start position The drain pump and door lock solenoid will activate and the washer will operate in high spin Safety warning if power is removed during this test the door can be opened To prevent injury do not put your hands inside when the tub is rotating 10 Turn the program knob 9 clicks from the start position The control will signal the last error code Quick Check If there is no error displayed and the washer momentarily starts then turns back off 1 Listen for a relay closure inside the Speed Control Board shortly after the Start key is pressed If this happens the motor control has power 2 Check the 5 pin connector wiring between the Console Control and the Speed Control Board 2 f Section 2 Washing Machines Frigidaire Diagnostic Mode continued In the Better models line the failure codes will appear in the display as an followed by two numbers a number and a letter or two letters The control will beep and the door lock wash rinse final spin and control indicator lights will flash Example 14 To stop the flashing the customer may touch the Pause Cance button The error code remains stored in the control but once the problem is corrected it does not effect the operation of the washer If the failure is some
28. ate switch alarm will sound If mold is on the right side camming of motor will cause bail arm to deactivate switch as well Fill limit switch test Top right switch Activate switch manually or rotate mold to right to activate Freezer limit switch test Top left switch Activate switch manually or rotate mold to the left to activate Evaporator heater cap tube heater Press On Off key to activate heater s test Electronic Expansion Valve EEV test Press On Off key to activate EEV Test will run for 120 seconds Th3 will check for accurate temperature drop p pass f fail if f check wiring to th3 thermistor and secure thermistor to underside of suction line remove electrical coil from EEV Check for moisture inside coil and on top of valve plunger Remove electrical connector from coil Check for moisture inside of connector Re connect connector and tighten clip that holds coil to valve by pressing clip toward center of valve Re install coil Retest Press On Off to activate motor Mold will rotate left to right to 63C Mold motor test assure proper switch activation and deactivation Software version will be displayed in left freezer window To deactivate ice maker test mode press and hold fresh food or Up arrow on Frigidaire models only for 5 seconds Manual Defrost Activation Press and hold fresh food and Up and Down arrows on Frigidaire models only simultaneously for 5 seconds Dand Fshould b
29. avy soil stain option deactivated The tub should be rotating and begin filling with water If the tub is not turning but is filling with water wait about 30 seconds after the tub is full and confirm the washer is agitating If the motor is running and the tub filled let the washer run for at least 6 8 pin connector J11 and pin 7 of the 7 pin connector J6 The minutes while measuring the voltage between pin 1 of the voltage should be below 50VAC when the timer advance is off and should measure at line voltage when the timer advance is on Constantly monitor the volt meter throughout this 6 minute run time to be certain to observe the voltage change as timer advance on is only on for a short time and could be missed when it reverts to the lower voltage reading when timer advance is off Stuck keypad or faulty connection at This type of fault could be temporary or permanent Check the the Main Control Board connection of the membrane tail to the Main Control Board for proper assembly DO DR Door open or door problem Close the door or check door switch and wiring Dispenser door open or dispenser door Close dispenser door Check reed switch operations problem Deep Clean Sanitary Cycle Error has been detected B o Section 2 Washing Machines Frigidaire Diagnostic Mode Better models have a digital readout display Good models do not have a digital readout display The diagnostic test is performed by using the progr
30. button and perform test again If key stuck code still exist replace Main Control Board Check resistance of outlet control thermistor and check wiring for open circuit Resistance should be between 4 9K ohms and 6 2K ohms at room temperature 68 77 f or 20 25 c Replace outlet control thermistor and or wiring and retest Check resistance of outlet control thermistor and check wiring for short circuit across thermistor connections Resistance should be between 4 9K ohms and 6 2K ohms at room temperature 68 77 f or 20 25 c Replace outlet control thermistor and or wiring and retest Check resistance of inlet control thermistor and check wiring for open circuit Resistance should be between 47k ohms and 66k ohms at room temperature 68 77 f or 20 25 c Replace inlet control thermistor and or wiring and retest Section 3 Dryers Error Code Description Solution Inlet control thermistor short circuit Check resistance of inlet control thermistor and check wiring for short circuit across thermistor connections Resistance should be between 47k ohms and 66k ohms at room temperature 68 77 f or 20 25 c Replace inlet control thermistor and or wiring and retest E91 Communication error Check connections between Main Control Board and User Interface Board If no wiring problems replace Main Control Board or User Interface Board Incompatible protocol Check if correct User Interface Board and Main Control Board are i
31. ck Freeze and Alarm Reset for 5 seconds or Shaped Control Press and hold micro switch on Main Control Board Vertical Control Select 0 then press Down key 4 times within 5 seconds Press Down key 4 Board On Door times within 5 seconds to exit Square Control Press and hold Fast Freeze and Mute Sounds for 5 seconds Board On Door Rectangle Horizontal Control Press and hold Extreme Freeze and Alarm Reset for 5 seconds Board On Door Freezer Defrost Mode Error bole i Code Description Solution a E2 Key stuck Replace Main Control Board High temperature in freezer compartment Communication failure Check wiring between the Main Control Board and the User Interface Board If correct replace the Main Control Board If problem still exists replace the User Interface Board ps stomeommode Stuck key or fail safe mode initiated Replace Main Control Board Check for thermistor failure Shorted thermistor Check the thermistor for shorts and wiring between Main Control Board to thermistor If correct replace thermistor Control Board to thermistor If correct replace thermistor Open thermistor Check the thermistor for an open circuit and wiring between Main a Thermistor operating correctly Section 8 Refrigerators DI AGNOSTIC MODE 19 CUFT ALL FREEZER AND REFRIGERATOR MODELS To initiate diagnostics mode press and hold Contro Lock for 3 seconds or until o is displayed for 1 second With the control locked press a
32. code amp NOTE A letter appearing in the code stands for a number higher than 9 A 10 B 11 C 12 D 13 E 14 and F 15 Example code 4A The first digit would be 4 and the second digit would be 10 If this code would appear on a washer in the non digital readout display models the four indicator lights would blink four times and the Start indicator light would blink 10 times To move on to the next code press the Options button To clear code press the Se ect button The code will be cleared when mode is exited Section 3 Dryers Affinity Diagnostic Mode Press and hold Select and Cancel buttons simultaneously for 6 seconds to reset the control The buzzer will sound 1 time and res will be shown briefly in the display Immediately after rotate cycle selector knob 5 turns counter clockwise to the second position from the bottom Press and hold the Options and Cancel buttons simultaneously for 2 seconds The control will enter test mode the buzzer will sound 3 times and all LED s will rapidly flash After entering the test mode the cycle selector knob can now be rotated to select the following test Rotate the cycle selector knob clockwise from the starting position 0 Turns All LED s will flash 1 Turn Drive motor runs heat source is on Drying LED is lit H and the control thermistor reading will toggle back in forth in the display 2 Turns Drive motor runs heat source is off Coo Down LED is lit and AF air fluff
33. connections are correct and secure e All electrical leads are properly dressed and secured away from sharp edges high temperature components and moving parts e All non insulated electrical terminals connectors heaters etc are adequately spaced away from all metal parts and panels e All safety grounds both internal and external are correctly and securely connected e All panels are properly and securely reassembled 2011 Electrolux Home Products Inc amp WARNING This service manual is intended for use by persons having electrical and mechanical training and a level of knowledge of these subjects generally considered acceptable in the appliance repair trade Electrolux home products cannot be responsible nor assume any liability for injury or damage of any kind arising from the use of this manual md Section 1 Basic Information This Manual has been prepared to provide Electrolux Service Personnel with Operation and Service Information for the proper service of Electrolux Appliances Table of Contents Section 1 Basic Information Safe Servicing Practices eeeeeeeeeeeeeeeeeeeeeeees 1 1 Table of Comte nt esasi iinn 1 2 Section 2 Washing Machines Error Code Charts cccceccsssseeeeseessseeeeeeeesasseeeesees 2 1 General Family Code Chart cccccecccssssseeeeeeeeneneees 2 8 Frigidaire Diagnostic MOde sseeeeeeeeeeeeees 2 11 To Recall an Error COd ccccecesssseeeeeeeeeaseeeeeeee
34. e displayed Section 8 Refrigerators Temperature Resistance Chart For NTC Thermistors Ice Maker Fresh Food Compartment TEMPERATURE OHMS TEMPERATURE OHMS 10 83 883 32 27 7 9 81 562 33 27 039 8 79 318 34 26 383 7 77 153 35 25 75 6 75 042 36 25 13 5 73 02 37 24 53 4 71 02 38 23 95 3 69 081 39 23 383 2 67 164 40 22 834 1 65 337 41 22 29 0 63 549 42 21 773 1 61 821 43 21 262 2 60 153 44 20 773 3 58 2 45 20 293 4 56 969 46 19 827 5 55 43 47 19 37 6 53 974 48 18 92 7 52 534 49 18 492 8 51 157 50 18 07 9 49 81 51 17 664 10 48 51 52 17 262 11 47 25 53 16 873 12 46 017 54 16 493 13 44 837 55 16 127 14 43 67 56 15 767 15 42 553 57 15 411 16 41 449 58 15 073 17 40 393 59 14 74 18 39 36 60 14 418 19 38 36 61 14 099 20 37 39 62 13 793 21 36 44 63 13 494 22 35 53 64 13 206 23 34 63 65 12 923 24 33 78 66 12 646 25 32 938 67 12 377 26 32 127 68 12 11 27 31 333 69 11 854 28 30 567 70 11 601 29 29 823 71 11 357 30 29 096 72 11 117 31 28 394 Section 8 Refrigerators Electrolux and Iceman Service Test Mode Service Test Mode Activation Press and hold freezer and Up and Down arrows on Frigidaire models simultaneously for 6 seconds or 10 seconds if not pressed at the same time Lights will shut off then all LED s will come back on Test Number Description Resolution Dispenser paddle test Press dispenser paddle Left window will display On when paddle is depressed and Off when paddle is released
35. essure switch Pressure sensor checks correct Go to step 7 Pressure sensor checks incorrect replace pressure sensor Replace the Main Control Board 2 8 Section 2 Washing Machines General Family Codes continued Error a i Code Description Solution Door switch or Main Control Board 1 Is the loading door closed No close the door Yes go to step problem 2 2 Disconnect the plug from J2 on the Main Control Board and check for continuity between the pins in the plug Open check the door strike If good replace the door switch assembly Closed replace the Main Control Board Hoses usually reversed Swap hot and cold hoses Internal control fault Unplug machine for a few seconds then re connect power Select a wash cycle and start cycle If F01 reappears replace the Main Control Board as there is likely an internal problem in the board If the cycle performs without displaying F01 the fault was temporary no repair is required at this time Water fill temperature problem The problem could be in the temperature sensor or the inlet hoses may be reversed In either case the control will try to resolve the error and the washer will continue to run Before testing the sensor first check the wiring to make sure it is properly connected To test the temperature sensor unplug the washer and disconnect wiring to the sensor Use an ohmmeter to measure the resistance of the sensor A reading below about 3K ohm or above abo
36. fective replace the reed switch Good replace the Main Control Board Check the drain hose for restrictions Restriction correct Water not pumping out fast enough problem No restriction go to step 2 Start the washer and check for 120VAC at the drain pump Zero replace the Main Control Board 120VAC remove the pump and check it for blockage If blocked remove the restriction if not replace the pump Drain pump relay on board failed or Replace Main Control Board or repair wiring wire off pump Section 2 Washing Machines Error o i Code Description Solution Drain pump relay on board failed or Replace Main Control Board or repair wiring wire off pump Recirculation pump relay sense Check wiring between Main Control Board and pump If correct go to step 2 Check wiring between Main Control Board and recirculation board If correct go to step 3 Check pump for open coil resistance check If correct replace Main Control Board Recirculation pump relay Check wiring between Main Control Board and pump If correct go to step 2 Check wiring between Main Control Board and recirculation board If correct go to step 3 Check pump for open coil resistance check If correct replace Main Control Board Better models pressure sensor not Inspect the wiring between the pressure sensor and the Main communicating with Main Control Control Board Defective wiring correct wiring Good wiring
37. ge condition L1 or L2 may Verify proper incoming line voltage and polarity of L1 L2 and be crossed with neutral on incoming neutral power supply connections at range terminal block power supply 2 If power supply voltage and polarity are correct replace EOC operating correctly Note thermal cut out will reset when unit cools down If Microwave Control Board has power check wiring between the User Interface Board J3 and the Microwave Control Board connector D If correct replace User Interface Board If problem persists replace Microwave Control Board F80 Communication error between the User 1 Verify the Microwave Control Board has power open Interface and the Microwave Control microwave door if light comes on Microwave Control Board Board has power If no power to Microwave Control Board check if external in line fuse is open fuse can be open due to over amperage or door switch issues 2 If F80 error code was triggered while oven was hot it could be due to an open thermal cut out in microwave Verify nothing is blocking the air flow of cooling fans and that cooling fans are Section 4 Range Error Code Solution Description Maximum oven door unlock time exceeded Communication break between Power Board and UIB Communication break between Power Board and UIB UIB not communicating Watchdog timer timed out power Watchdog timer timed out UIB Potentiometer LF is open Potentiometer LR i
38. gnostic 8 3 Icemaker Test Mode Activation cccccssseeeeeeeeenes 8 3 Manual Defrost Activation c ccccccsseeeeseeeeeeeees 8 4 Temperature Resistance Chart for NTC Thermistors Ice Maker fresh food compartment n se 8 5 Electrolux Service Test MOd cccccsseceesseeeeeseeeees 8 6 Service Test Mode Activation 8 6 Manual Defrost Activation c cccccssseeesseeeeeeaees 8 7 Frigidaire Side by Side Error Codes secre 8 8 Defrost Activation MOde ccccsseeceeseeeeesseeeeeseeeees 8 8 Freezer Defrost Mode ccccseccecsseceesseeeesseeeeesaaeees 8 9 Diagnostic Mde riisiiniensr ninina 8 10 19 cuft all freezer and refrigerator models 8 10 21cuft 17cuft and 14 cuft all freezer models 8 11 Exiting Diagnostic MOe cssseeeeeeeeeeeeeeeeeeees 8 11 Diagnostic MOCe ceeeeeeeeeeeeeeeeeeeeaeaeaeeeeeeeeeeeeeeees 8 10 Electrolux 42 built in refrigerator sses 8 12 Diagnostic 42 built in refrigerator 8 13 Section 9 Wine Cooler Beverage Center Error Code Charts siiiesssiiscseeessssavecssweecsseeidensaees 9 1 Diagnostic MOCe ceceeeeeeeeeeeeeeeeee esas eeeeeeeeeeeeeeees 9 1 Sabbath MOd iisccssseccceteeccevcesstevesstevcessevieesweessneves 9 2 Section 10 Air Conditioners Error COdE CHAS annissa aa 10 1 Section 2 Washing Machines Error i Code Description Solution E10 E11 Fill time too long Is the incoming water flow normal Yes go to step 4 No go to step 2
39. hdog reset Clear code exit mode and start dryer If problem persists replace Main Control Board Section 3 Dryers Frigidaire Diagnostic Mode 1 On non digital readout display models position the cycle selector knob to the 12 o clock position On digital readout display models position the cycle selector knob to the Normal cycle option 2 Press and hold the Select and Pause Cancel buttons simultaneously for six seconds 3 Immediately after press and hold the Start and Pause Cance buttons simultaneously for 4 seconds The control will enter test mode the buzzer will sound 3 times and all LED s will rapidly flash After entering the test mode the program knob can now be rotated to select the following tests Rotate the knob clockwise from the start position 1 Turn drive motor runs heat source is on Drying LED is lit H and the control thermistor reading will toggle back and forth in the display amp NOTE For models that do not have a digital display the Dryness LED s could be used to determine the control thermistor temperature Reading The number of flashes of the bottom three LED s will determine the value of the temperature as follows Example Normal flashes 1 time Norma hundred s Less Dry flashes 2 times Less Dry ten s Damp flashes 6 times Damp one s temperature 126 2 Turns drive motor runs heat source is off Coo Down LED is lit and Af air fluff is displayed 3 Turns drive mo
40. idaire models use Up and Down arrows instead of or respectively Test o Number Description Resolution pc ranere icemar O fac _ arest Motor stuet in freze Poston e Good 2 or 3 Badi Er evor 44C Position se p Freezer recovery mode freezer 1 Ok FR recovery mode for more than 24 hrs recovery mode is activated whenever the temperature rises 8 10 above the set point of the freezer and will not exit recovery mode until temperature in freezer is within 4 6 from the set point depending on model While in re ice maker will be off hac Electronic Expansion Valve EEV test On Open Off Closed to activate press the On Off key Communication test between Ice Maker 1 Good Er Error Control Board and Main Control Board Thi mold thermistor test 1 Good OP Open Er Error 2c Th3 EEV thermistor test 1 Good OP Open Er Error ot Mold heater test Press On Off key to activate mold heater Finger evaporator heater test Press On Off key to activate finger heater if mold is in the left position mold will rotate to the right Section 8 Refrigerators Fresh Food I cemaker Diagnostic continued Test Number Description Resolution Water fill test Press On Off key to activate test mold will rotate right to left catch water in cup on right 3 4 Oz Fill for 4 seconds a Evaporator fan test Press On Off key to activate evaporator fan Ice level switch test Lift on ice maker bail arm to deactiv
41. igerators DI AGNOSTIC MODE 21CUFT 17CUFT AND 14 CUFT ALL FREEZER MODELS To initiate diagnostic mode set the temperature to 0 F then press and hold the Up and Down keys simultaneously for 3 seconds 88 will be displayed and a confirmation tone will sound Press the Up key to display the model number Once you have displayed the model ID press and hold the Up and Fast Freeze keys for 3 or more seconds to select the option to change the model ID Change the model ID by pressing Up or Down keys Save the model ID by pressing Mute Sounds button Model Description Model ID C20 C25 U21F 0 U20F U17F 1 C14F U14F 2 Press the Fast Freeze key to display the production software for the model The limitation is 00 99 production software versions per model The minus and 2 digit version number xx is displayed Press the Down key to display the door switch status If the door switch is open the letter d0 is displayed If the door switch is close the letter dc is displayed Press the Mute Sounds key to display the thermistor status If the thermistor is operating properly will be displayed If the thermistor is open the letter t0 will be displayed If the thermistor is shorted ts will be displayed The thermistor status is not updated in showroom mode Is always displayed Press the Fast Freeze key while in software version is displayed to reset all EEPROM values to the factory defaults The model ID
42. in 10 seconds after pressing Cancel press any button except the Cancel button to wake up the control Within 5 seconds of wake up turn the selector knob to the far eft cycle and press and hold the Cancel and center button under the display simultaneously for 3 seconds to enter the diagnostic mode amp NOTE To save time at wake up the Welcome screen can be bypassed by turning the selector knob 1 Upon entering diagnostic mode all lights should flash for 1 1 4 x 2 display models 2 Turn the program knob 1 click clockwise from the start position The hot water solenoid will activate and hot water should enter through the detergent compartment 3 Turn the program knob 2 clicks from the start position The bleach water solenoid will activate and cold water should enter through the bleach compartment 4 Turn the program knob 3 clicks from the start position The bleach and wash water solenoids will activate and cold water should enter through the softener compartment 5 Turn the program knob 4 clicks from the start position The prewash solenoid will activate and cold water should enter through the prewash compartment 6 Turn the program knob 5 clicks from the start position The door lock solenoid will deactivate and the loading door can be opened When the door is opened the drum light should turn on if so equipped Section 2 Washing Machines Affinity Diagnostic Mode newer models continued 7 Turn the pr
43. is displayed 3 Turns drive motor runs heat source is off Drying and Cool Down LED s are lit and numbers appear in the display showing moisture sensor readings Opening the door press in on door switch plunger and placing finger on both moisture sense bars at the same time will make the numbers decrease In controls that do not have a digit display the More Dry LED should be on Opening the door press in on door switch plunger and placing finger on both moisture sense bars at the same time will make the Damp LED come on 4 Turns Drive motor runs heat source is off Key test A When the Temperature key is pressed all the temperature LED s should light B When the Dryness key is pressed all the Dryness level LED s should light C When the Options or Select key is pressed all the Option LED s should light D When the Start Pause key is pressed all the cycle status LED s should light E When the Cancel key is pressed all the cycle status LED s should light 5 Turns Drive motor runs heat source is off Coo Down LED is lit Control thermistor reading is displayed 6 Turns drive motor runs heat source is on Drying LED is lit Control thermistor reading is displayed 7 11 Turns All LED s will flash Exiting Diagnostic Mode Press and hold the Se ect and Cance buttons simultaneously for 6 seconds or disconnect power from dryer Dryer will be reset for regular operations To Recall an Error Code Press and hold Se
44. l Fresh food thermistor test OP Open Er Error fresh food temperature should be displayed Freezer thermistor test OP Open Fr Error freezer temperature should be displayed Ambient temperature test OP Open Fr Error ambient temperature should be displayed Press On Off key to activate and deactivate test mode While in service test mode you must turn off each component that is turned on if you do not want component to stay activated To deactivate test mode press and hold fresh food or Up arrow Frigidaire models for 5 seconds Manual Defrost Activation Press and hold fresh food and Up and Down arrows on Frigidaire models only simultaneously for 5 seconds D and F should be displayed Section 8 Refrigerators Frigidaire Side by Side Error Codes Error Code Description Resolution Evaporator fan failure Check wiring between evaporator fan and Main Control Board Check for 12VDC to fan between red and brown wires Check for variant voltage depending on high or low speed between yellow and brown If correct replace evaporator fan If error code still exist replace Main Control Board 2 In fresh Fresh food thermistor open Check wiring between fresh food thermistor and Main food window Control Board If correct replace thermistor If problem still exist replace Main Control Board Fresh food thermistor shorted Check wiring between fresh food thermistor and Main Control Board If correct replace
45. lay Degrees F Motor CW Motor CW Check motor and heater function HEAT3 NTC1 Outlet control heater 1 heater Check outlet control thermistor value thermistor value heater 2 in digit display Degrees F heater 3 Motor CW Check For Mist Mist Value Error Code History Display Check last 5 error codes displayed Error Code see table above for error code definitions Software Version Software Version Software Software Version Version Exiting Diagnostic Mode A Unplug the power cord wait 5 8 seconds then reconnect the power cord or B Turn the program knob to the start position lights button test Press the Cancel and far eft button under the display simultaneously for 6 seconds To Clear Stored Error Code Press and hold the far eft button under the display and Cance buttons simultaneously for 3 seconds Factory Reset 1 Turn cycle selector knob to any position other than My Favorites 2 Press the Up arrow button until set prefs appears 3 Press the Se ect button 4 Press the Up arrow button until reset appears 5 Press the Se ect button 6 Press the Menu button under Al Settings 3 11 Section 3 Dryers Electrolux Diagnostic Mode continued Installation Cycle 1 Turn cycle selector knob to any position other than My Favorites 2 Press the Up arrow button until set prefs appears 3 Press the Se ect button 4 Press the Up arrow button until install cycle appears 5 Press the Se ect button
46. le and press and hold the Cancel and center button under the display simultaneously for 3 seconds to enter the diagnostic mode amp NOTE To save time at wake up the Welcome screen can be bypassed by turning the selector knob Turn the program knob clockwise 9 turns clicks from the start position The control will signal the last 5 error codes with E00 meaning no error experienced Press and hold the center key under the display and Cance buttons simultaneously for 3 seconds The code s will be cleared Exit diagnostic mode to return to normal operations Factory Reset On 1 1 4 x 2 display models wake machine push the Spin Speed and Soil Selection keys simultaneously and hold until you hear a beep This is no more than 10 seconds 2 16 Section 2 Washing Machines Electrolux Diagnostic Mode Press the Cancel button to enter standby mode and enable diagnostic entry Within 10 seconds after pressing Cancel press any button to wake up the control Within 5 seconds of wake up turn the selector knob to the far eft cycle and press and hold Cancel and far left button under the display simultaneously for 3 seconds to enter the diagnostic mode amp NOTE To save time at wake up the Welcome screen can be bypassed by turning the selector knob jak Upon entering diagnostic mode all lights should flash for 1 x2 display models and all lights on for the 11 4 x 4 3 4 display models 2 Turn the
47. led Microwave external cooling fan speed Check if the microwave external cooling fan outside the is abnormally slow microwave chassis is turning This fan is supposed to be active anytime the microwave is in use and expected to stay on a few minutes after the microwave cycle is complete A fan not turning at all or a fan turning abnormally slow will trigger an F43 fault code If the fan is not turning or turns very slowly check for 120VAC to the fan If 120VAC is present and fan does not turn replace the fan If 120VAC is not present check the wiring between Microwave Control Board P16 and cooling fan If correct check for 120VAC at microwave control board Is fan correctly connected between P15 and neutral If fan appears to turn normally there is a problem between the fan speed sensor and Microwave Control Board Check wiring between fan speed sensor and Microwave Control Board P19 If correct replace fan If problem persists replace Microwave Control Board Microwave external cooling fan speed Visually inspect the external cooling fan This fan is supposed is abnormally fast to be active anytime the microwave is in use and expected to stay on a few minutes after the microwave cycle is complete Verify there is nothing blocking the air flow of the fan which would make the fan turn faster Check for 120VAC at the fan A voltage higher 120VAC 10 could make speed of fan increase If fan appears to turn nor
48. m Check the wiring between the Main Communication problem Control Board and the Speed Control Board Wiring bad correct wiring problem Wiring good replace the Main Control Board If the problem is not corrected replace the Speed Control Board Communication problem Refer to E5D solution Communication problem Refer to E5D solution E F E66 Heating element relay failure 1 Check the resistance of the heating element It should be appoximately 14 ohms 2 Check the resistance between the ground and both heater terminals It should be open when heater terminals are disconnected If the readings are incorrect replace the heating element If the readings are correct replace the Main Control Board E67 Input voltage on microprocessor Replace the Main Control Board incorrect Current leakage to ground on 1 Check the resistance of the heating element It should be heater or fuse opened appoximately 14 ohms 2 Check the resistance between the ground and both heater terminals It should be open when heater terminals are disconnected If the readings are incorrect replace the heating element The Main Control Board is not seeing Swap hot and cold hoses the correct water supply swap hot and cold hoses Wash NTC failure tub heater Swap hot and cold hoses Wash temperature does not increase Place NTC in correct position 75 sensor circuit replace the water inlet valve assembly Yes replace the Main E Better models water te
49. mally there is a problem between the fan speed sensor and Microwave Control Board Check wiring between fan speed sensor and Microwave Control Board P19 If correct replace fan If problem persists replace Microwave Control Board Section 4 Range Error _ Code Description Solution F60 EOC oven temperature higher 1 Verify proper assembly of backguard panel Check for damaged than normal temperature detected on or loose panels brackets endcaps etc iie ROG 2 Check for blocked ventilation slots in control panel rear cover 3 Inspect oven vent for proper assembly and air flow 4 Verify operation of cooling fan if present F62 F63 Internal signal voltage error display Disconnect power wait 30 seconds and reapply power If fault communication error returns upon power up replace EOC Time base failure the EOC cannot Confirm that range is connected to power source 50hz or determine if connected to 50 or 60hz grids etc may not provide proper power supply If power power supply source is correct replace the EOC 7 Keyboard short circuit or internal EOC 1 Test keyboard circuits using test matrix Replace touch panel if A 60hz Generators or other portable power supplies and solar F65 failure defective 66 2 If keyboard circuit checks correct replace EOC F EOC internal power supply failure Disconnect power wait 30 seconds and reapply power If fault returns upon power up replace EOC F68 F69 High volta
50. mperature Check the resistance of the NTC Is it around 50k ohms No Control Board 76 Better models NTC temperature for Swap hot and cold hoses the cold water valve over the limits Console Control problem Replace the Main Control Board E83 a Console Control problem Replace the Main Control Board Section 2 Washing Machines Error ee i Code Description Solution Communication problem Check the wiring between the Main E91 User Interface to Main Control Board Control Board and the User Interface Board Wiring bad E92 communication error correct wiring problem Wiring good replace the User Interface Board If the problem is not corrected replace the Main Control Board Console Control problem Replace the Main Control Board Console Control problem Replace the Main Control Board Console Control problem Replace the Main Control Board Console Control problem Replace the Main Control Board Communication problem Check the wiring between the Main Control Board and the Speed Control Board Wiring bad correct wiring problem Wiring good replace the Main Control Board If the problem is not corrected replace the Speed Control Board Communication protocol Power supply voltage too high Have the power company check the frequency and voltage of the incoming power If correct for error code E5C replace the Speed Control Board If correct for error codes EA1 EA2 EA3 EAS EAE or EA5 replace the Main Control Board Power
51. ncel press any button to wake up the control Within 5 seconds of wake up turn the selector knob to the far eft cycle and press and hold the Cance and the far eft button under the display simultaneously for 3 seconds to enter the diagnostic mode amp NOTE To save time at wake up the Welcome screen can be bypassed by turning the selector knob Turn the program knob clockwise 9 clicks from the start position The control will signal the last 5 error codes with E00 meaning no error experienced Press and hold the far eft key under the display and Cance buttons simultaneously for 3 seconds The code s will be cleared Description General EEPROM fault Checksum internal processor check error Non fatal reading or writing to the memory error Control NTC short circuit Control NTC open circuit Door sensing failure Motor relay failure Motor fault motor stopped or not starting Motor centripetal switch failure Motor sensing failure Section 3 Dryers Solution Clear code exit mode and start dryer If problem persists replace Main Control Board Clear code exit mode and start dryer If problem persists replace Main Control Board Clear code exit mode and start dryer If problem persists replace Main Control Board Measure resistance of control thermistor If reading is not 50k ohms 10 replace thermistor If reading is within 50k ohms 10 check wiring between the thermistor and Main Co
52. nd hold Up and Down keys simultaneously for 5 seconds The control will display the following in 2 second intervals The system will then wait for load testing for 10 seconds If load testing is performed a 10 second wait cycle is re established after each key press This is followed by defrost cycle time adjust mode After exiting diagnostic mode the control will also exit control lock mode Three 3 short confirmation tones sound Left digit displays 8 right digit is blank Left digit is blank right digit displays 8 C F Ars door ajar and power fail LED s are illuminated Hi temp duration replace air filter and control lock LED s are illuminated Displays ID model ID with tone Displays model ID Displays 5F software version with tone Displays software version number Door switch status with tone DO or DC Thermistor status with tone 70 for open 7C for closed or for good thermistor Tone and enters load test mode for 10 seconds 1 Press down V key Displays he and turns on the heater 2 Press up A key Displays cp and turns on the compressor 3 Press Temp Mode key Displays a and illuminates cabinet lamp Enters defrost cycle time adjust mode Default is 12 hours Time can be adjusted for 8 10 or 12 hours by using Up A Down V keys The compressor run time will also be adjusted Diagnostics mode exits at end of 10 second load test mode 8 10 Section 8 Refr
53. neously for six seconds or disconnect power from dryer Dryer will be reset for regular operations To Recall an Error Code On non digital display models rotate cycle selector knob to the 3 o clock position On digital readout display models rotate the cycle selector knob clockwise 3 settings from the Normal cycle option Press and hold the Select and Pause Cance buttons simultaneously for 6 seconds Immediately after press and hold the Start and Pause Cancel buttons simultaneously for 4 seconds On digital readout display models rotate the timer knob 1 click counterclockwise The error code will appear in the digital display On non digital display models rotate the cycle selector knob to the 2 o clock position The four indicator lights of drying cool down wrinkle rid press saver and clean lint filter will flash the number of times for the first digit of the code and the Start indicator light will flash the number of times for the second digit Take separate counts of each indicator light then repeat to confirm in order to be accurate in identifying the proper error code The code is obtained by counting the number of times the lights flash Example 24 the four indicator lights would flash twice indicating the 2 and the Start indicator light will flash four times indicating the 4 The four indicator lights and the Start indicator light start flashing at the same time The control will pause for 2 seconds then repeat the
54. ns 4 and 5 in the motor If the meter reads other than between 105 and 130 ohms replace the motor If the reading is between 105 and 130 ohms go to step 4 Disconnect the plug from the motor and measure the resistance of the windings pin 1 to 2 pin 1 to 3 pin 2 to 3 All readings should be between 4 and 6 ohms If readings are correct replace the Speed Control Board If readings are incorrect replace the motor Door PTC sensing problem Is the loading door closed No close the door Yes go to step 2 Can you hear the lock attempt to close Yes check the door strike If good replace door switch No go to step 3 Check the wire connection between the door lock and the Main Control Board If good go to step 4 Place the unit into Rinse Spin and remove any load from tub Start the cycle Does the water pump out If not check the drain hose for restrictions Check the drain pump for 120VAC at pump If no power at pump check wiring If correct check for 120VAC at Main Control Board If unit does pump out does unit go into spin If no replace door lock If problem continues replace Main Control Board E5A High temperature on heat sink caused Replace the Speed Control Board by overloading High temperature on heat sink Replace the Speed Control Board High temperature on heat sink Replace the Speed Control Board Section 2 Washing Machines Error o i Code Description Solution Communication proble
55. nsor and wiring connections Inspect oven cavity outer casing and insulation Replace touch key pad Section 7 Dishwasher Code Description Solution Vent open While in wash cycle Main Control Board does not receive signal from vent assembly that vent plunger is closed Plunger status is sensed with optical sensor in vent assembly Check wiring between vent assembly and Main Control Board If wiring correct replace vent assembly If error still exist replace Main Control Board Fan not running While in drying cycle Main Control Board not sensing vent fan motor rotation at correct speed Check wiring between vent assembly and Main Control Board If correct replace vent assembly If error still exist replace Main Control Board Membrane switch Main Control Board has detected a stuck key or a key pressed failure for more than one minute Check connection from keypad to Main Control Board If correct replace keypad If error still exist replace Main Control Board Note washing drying and clean s may appear in display when error code is present Configuration error Check wiring connections between keypad and Main Control Board Check for correct parts installed Replace parts accordingly Close door door switch open Main Control Board not sensing door closed Close door Check door switches Check wiring between door switches and Main Control Board If wiring and switches are correct replace Main Control Board 2 Displa
56. nstalled Replace appropriate hardware Replace User Interface Board and or console Main Voltage sensing failure Check vent restrictions and resistance values of exhaust control thermistor and inlet control thermistor Max timeout timer Check vent restriction contact sensor and resistance values of exhaust control thermistor and inlet control thermistor User Interface Board as appropriate Program timeout fault Check for anything that would extend dry times such as no max time exceeded for that cycle heat restricted vent blower fan blade broken or loose dryer installed in closet with solid door bad connection in moisture sensor bar circuit or dirty bars if dryer operates normally and code returns replace Main Control Board Heater fault temperature reading of Check heater relay on Main Control Board thermostats in the control thermistor has not changed heater circuit heater and control thermistor in a set amount of time Key stuck Check buttons for activation when pressed Replace console or Section 3 Dryers Error _ Code Description Solution Too many trips of the safety Check for blocked lint filter blocked exhaust air leaks around thermostat in a period of time air duct broken or clogged fan blades worn or loose drum seals and door seal E9B External EEPROM communication or Replace User Interface Board data corruption Low or intermittent voltage to board House wiring power supply problem AF E Watc
57. ntrol Board If good replace Main Control Board Measure resistance of control thermistor If reading is not 50k ohms 10 replace thermistor If reading is within 50k ohms 10 check wiring between the thermistor and Main Control Board If good replace Main Control Board Check the contact sensor and wiring If no problems are found with contact sensor replace Main Control Board Check door switch and wiring If correct replace Main Control Board If motor runs continuously with power applied check for short circuit across motor relay RL2 or L1 applied to motor relay output J3 1 with cycle stopped If motor does not start when Start key is pressed check for open circuit between L1 and motor relay connection J3 2 If no wiring problems found replace Main Control Board Remove any load from dryer and check if drum turns freely by hand Check L1 power supply voltage motor windings and motor thermal protector if motor thermal protector has tripped it may take up to 30 minutes to reset Check wiring Check if motor centripetal switches are stuck in open or closed positions Replace motor Replace Main Control Board Replace Main Control Board Section 3 Dryers Error Code Description Heater relay failure Heater to earth ground Heater open circuit High limit thermostat trip count too high Thermal limiter open circuit Heaters sensing failure Key button stuck fault Outlet control the
58. od heater ON 2 Fresh food and freezer heaters ON 3 Fresh food and freezer heaters OFF Pressing the pad a fourth time will cycle through the sequence again During the sequence heater current can be measured e Fresh food heater approximately 1 2 amps when measured at the CNO1 connector black wire e Fresh food and freezer heaters approximately 4 amps when measured at the CNO1 connector black wire 8 14 Section 8 Refrigerators Diagnostic Electrolux 42 built in refrigerator continued Details of Self Diagnosis Light Display by Position I M SENSOR FRIDGE SEGMENT R SENSOR FRIDGE SEGMENT R Defrost Sensor jem ET _ FRIDGE SEGMENT IM Function Error FRIDGE SEGMENT Fresh Sensor FRIDGE SEGMENT FREEZER SEGMENT Ambient Temperature Sensor FREEZER SEGMENT FREEZER SEGMENT oe i FREEZER SEGMENT EF FREEZER C FAN ERROR oon FREEZER SEGMENT FREEZER SEGMENT ois FREEZER SEGMENT MAIN_PANEL ERROR Uart Communication Fe SEGMENT Error PLC R FAN ERROR R Defrost Error M 15 I M Sensor Housing slip out Contact Failure Wire Cut Wire Short Defective M Sensor Sensor Housing slip out from the R Room Contact Failure Wire Cut Wire Short Defective R Sensor Defrost Sensor Housing slip out from the evaporator of R Room Contact Failure Wire Cut Wire Short Defective Sensor Errors in operation of R FAN Motor Contact failure of feedback signal wire
59. ode Description Solution Leak detected Water detected in base Repair leak Retest Thermistor turbidity Thermistor Turbidity sensor failure Check wiring If correct sensor failure replace turbidity sensor If error still exist replace Main Control Board Wash motor Wash motor or wash motor hall sensor failure Check for suds in tub Check for syphoning or no fill conditions Check wiring between motor and Main Control Board If correct replace wash motor If error still exist replace Main Control Board Drying damper Drying damper not operating correctly Check wiring between Main Control Board and upper fan If correct replace upper fan Upper fan When in the dry cycle the control does not receive the proper speed feedback from the upper fan Replace upper fan Lower fan When in the dry cycle the control does not receive the proper speed feedback from the lower fan Replace lower fan E07 Drain valve While in drain cycle Main Control Board did not receive proper signal from drain valve Check wiring between Main Control Board and drain valve If correct replace drain valve If error still exist replace Main Control Board Tactile switch Control has detected a stuck or shorted key on User Interface failure uib Board Check wiring between Main Control Board and User Interface Board If correct replace User Interface Board If error still exist replace Main Control Board Communication error Communication failure between Main
60. ogram knob 6 clicks from the start position The door lock will activate and the washer will fill then tumble Once tumbling has started the boost heater will turn on 8 Turn the program knob 7 clicks from the start position This is a free position on models without recirculation pump The recirculation pump and drum light will activate if so equipped 9 Turn the program knob 8 clicks from the start position The drain pump will activate draining out any water in the tub To enable spin press the Delay Start key 10 Turn the program knob 9 clicks from the start position The control will signal the last 5 error codes with E00 meaning no error 11 Turn the program knob 10 clicks from the start position Latest software version will be shown 12 If applicable turn the program knob 11 clicks from the start position This is a free position Exiting Diagnostic Mode To return the washer to normal operations A Unplug the power cord wait 5 8 seconds then reconnect the power cord or B Turn the program knob clockwise back to the start position Press the Cancel and center button under the display until the LED s stop flashing To Clear The Last Stored Error Codes Press the Cancel button to enter standby mode and enable diagnostic entry Within 10 seconds after pressing Cancel press any button except the Cancel button to wake up the control Within 5 seconds of wake up turn the selector knob to the far eft cyc
61. ol cooking zones Board in the 3 zones Induction Module Replace Generator Control Board for the center cook zone in the 3 zones Induction Module Heat sink temperature sensor break in Replace Generator Control Board for the center cook zone in the 3 the 3 cook zones Induction Module for zones Induction Module the center cooking zones Flash ROM check fail EEPROM data Replace Control Board left board Shift register issue on right touch 1 Verify the flex cable between boards board Replace the right touch board Replace the middle touch board 36 models only Replace the Control Board left board Shift register issue on middle touch Verify the flex cable between boards board Replace the middle touch board Replace the Control Board left board AC input voltage too high Verify AC input voltage at the cooktop input Verify AC main input cables screws and jumpers Replace the Filter Board on Induction Module Synchronous impulse net zero Test cables and connections on Induction Module Replace the crossover touch control must request Generator Control Board on the Induction Module a power level to detect this issue 12VDC on the service section too low Test all cables and connections on Induction Module Induction Module Replace the Generator Boards on the Induction Module 5VDC overcurrent on the switched Replace the Filter Board on Induction Module 5VDC on the service section Sub
62. ol to enter a special factory test mode Disconnect power to reset the control to return washer to normal operation if this occurs To Clear The Last Stored Error Codes Place the control into diagnostic mode Turn the program knob clockwise 9 clicks from the start position The control will signal the last error code Press and hold the Options and Pause Cancel buttons for 3 seconds The code will be cleared Exit diagnostic mode to return the washer to normal operations 2 13 Section 2 Washing Machines Affinity Diagnostic Mode The diagnostic test is used to check individual component function only Turn the program knob to the start position far eft cycle Press the Start Pause button to start the cycle and save it Press the Cancel button to stop the cycle and turn off the LED s Press the Cancel button again to turn on the LED s Within 5 seconds press and hold the Options and Start Cance buttons until LED s start flashing then release buttons 1 All the LED s will flash Pressing a button below a light cluster will light all the LED s in that cluster at one time to confirm functionality 2 Turn the program knob 1 click clockwise from the start position The hot water solenoid will activate and hot water will enter through the detergent compartment 3 Turn the program knob 2 clicks from the start position The bleach water solenoid will activate and cold water should enter through the bleach compa
63. oming line voltage below 90VAC Check voltage at the outlet If above 90VAC replace the Main Control Board Console control problem Replace the Main Control Board Console control problem Replace the Main Control Board Clogged drain pump Unclog the drain pump Advise the customer to reduce the amount of soap they are using NTC temperature for the hot water Hot and cold water hoses switched Swap hoses valve over the limits Control reset Unplug the unit for 1 minute and plug back in If problem is not corrected replace Main Control Board Key stuck Check all buttons If correct replace User Interface Board General Family Codes No error code is stored E10 Fill time problem too long to fill or air 1 Is the incoming water flow normal Yes go to step 4 No go leak at dome or pressure switch to step 2 Are the incoming water faucets turned on No turn water faucets on Yes go to step 3 Is the incoming water pressure above 30 psi No have customer correct pressure problem Yes check for kinked or blocked incoming water hoses clean incoming water screens If problem still remains replace the water inlet valve assembly Does the fill water continue to enter the washer Yes go to step 5 no go to step 6 Remove power from washer Did the water fill stop Yes go to step 6 No replace the inlet valve assembly For Better models check the electronic pressure sensor For Good models check the pr
64. on left board Main On Off key sensor for Main Power Size key sensor for cook place 2 right position left board AC input voltage too high at the 3 cook zones Induction Module Internal generator error sync in the 3 cook zones Induction Module left side cooking zones 12VDC on the service section too low Relay Board Solution Change left board 1 Test flex cable between boards 2 Change right board 3 Change center board on 36 models only 4 Change left board Change left board Verify AC input voltage at the cooktop input Verify AC main input cables screws and jumpers Replace the Filter Board in the 3 zones Induction Module Test cables and connections on left side Generator Control Board dual Replace the Generator Control Board LF LR in the 3 zones Induction Module Check harness between Induction Module Relay Board and Main Control Board If correct replace Relay Board Description Improper voltage output from Filter Board in the 3 cook zone Induction Communication failure between Filter Board and Power Boards in the 3 cook zones Induction Module left side cooking zones AC input voltage too low in the 3 cook zones Induction Module Touch LIN error no communications shorted bus Section 5 Induction Cooktop Solution Test all cables and connections on Filter Control Board in the 3 zones Induction Module Replace the Filter Control Board in the 3 zones Ind
65. on a combination of pushed buttons may have caused the control to enter a special factory test mode Disconnect power to reset the control to return washer to normal operation if this occurs Domed Section 2 Washing Machines Affinity Diagnostic Mode continued To Clear The Last Stored Error Codes Turn the program knob to the start position far eft cycle Press the Start Pause button to start the cycle and save it Press the Cancel button to stop the cycle and turn off the LED s Press the Cancel button again to turn on the LED s Within 5 seconds press and hold the Options and Start Cance buttons until LED s start flashing then release buttons Turn the program knob clockwise 7 clicks from the start position The control will signal the last error code Press and hold the Options and Pause Cance buttons for 3 seconds The code will be cleared Exit diagnostic mode to return to normal operations To Recall an Error Code 1 Wake the washer by pressing any button 2 Wait 5 seconds 3 Press and hold the Start Pause and Cancel buttons simultaneously As long as the buttons are held the failure code will appear in the display as an E followed by two numbers a number and a letter or two letters The control will beep Affinity Diagnostic Mode newer models The diagnostic test is used to check individual component function only Press the Cance button to enter standby mode and enable diagnostic entry With
66. onds of entering the diagnostic mode or it will time out normal refrigerator operation will resume and the displays will turn off Once a test mode is selected the display will flash to confirm the mode selected 5 At the end of a test session to exit the diagnostic mode do one of the following e Enter 1 on the FREEZER display and 5 on the REFRIGERATOR display Press any pad other than the COLDER or WARMER pads to e xecute a system restart e Enter 1 on the FREEZER display and 6 on the REFRIGERATOR display Press any pad other than the COLDER or WARMER pads to exit the service diagnostic test mode e Recycle power to the unit through the main switch As a cautionary measure the system will automatically time out of the diagnostic mode after 15 minutes of inactivity In the diagnostics mode the unit can be tested under different conditions Section 8 Refrigerators Diagnostic Electrolux 42 built in refrigerator continued Test Mode Chart FZ Display FFDisplay Mode Commens o ShowoomMode Senos o 2 oons SSS SSS S 3 e SSCS 0 4 e S s Donotuse SCS 6 __ Hi serrTest___ E T T 7 contra and Sensor SofTest Seene Pe Donets SSCS e Dispenser Recess Heater Test 0 1 Doo Use Each fan wilrun for seconds 120 Runtime SCS Noto 1 3 _Donotue S CSCSCSCSCS 1 4 _ eagle the State of Defrost E aC 1 s RergeaorReset Causes a system reset excopt for defrost P
67. or Evaporator sensor shorted Check wiring to evaporator sensor If correct replace sensor Communication error Check wiring between the User Interface and the Main Control Board If correct replace User Interface If error still exist replace Main Control Board Incorrect user interface Check if correct User Interface and Main Control Board have been installed Replace the User Interface or Main Control Board accordingly Diagnostic Mode To enter the service mode press and hold the Vacation Mode key while pressing the On Off key 3 times in 5 seconds Temperature digit display will show 1 Each press of the left hand temperature Up or the left hand temperature Down key will step through the service tests 1 through 6 Press the Mute Sounds button to access the test selected Once the test is accessed the display will show and each press of the temperature Up key will cycle forward through the test features a e and display the test information in the display Each press of the temperature Down key will cycle back through the test features Pressing the Mute Sounds key will exit from the test and display the current service test number Test Number Description Firmware version displays firmware version User Interface and Main Control Board Evaporator fan toggles the evaporator fan s on and off Primary sensor will display P1 Normal P2 Open P3 Shorted Compressor toggles the compressor on and
68. or at power up Check wiring between Main Control Board and User Interface Board Replace User Interface Board If problem still exist replace Main Control Board Communication Failure after power up Check wiring between Main Control Board and User Interface Board Replace User Interface Board If problem still exist replace Main Control Board No defrost circuit Check wiring between defrost circuit and Main Control Board If correct replace Main Control Board Section 8 Refrigerators Temperature Resistance Chart For NTC Thermistors Frenchdoor And Side By Side Models TEMPERATURE OHMS TEMPERATURE 10 117 240 32 9 113 460 33 8 109 814 34 7 106 298 35 6 102 908 36 5 99 637 37 4 96 481 38 3 93 436 39 2 90 498 40 1 87 662 41 0 84 925 42 1 82 283 43 2 79 732 44 3 77 268 45 4 74 890 46 5 72 592 47 6 70 373 48 7 68 229 49 8 66 158 50 9 64 156 51 10 62 222 52 11 60 352 53 12 58 545 54 13 56 798 55 14 55 109 56 15 53 476 57 16 51 897 58 17 50 369 59 18 48 892 60 19 47 462 61 20 46 076 62 21 44 741 63 22 43 447 64 23 42 193 65 24 40 981 66 25 39 806 67 26 38 670 68 27 37 569 69 28 36 503 70 29 35 471 71 30 34 472 72 31 33 504 Section 8 Refrigerators Fresh Food I cemaker Diagnostic Ice Maker Test Mode Activation Press and hold fresh food and freezer for 6 seconds or 10 seconds if not depressed at the same time 48C or 40C depending on model should be displayed in right window Frig
69. or value thermistor value heater 2 in digit display Degrees F heater 3 Motor CW Check for mist Mist Value Error Code History Display Check last 5 error codes displayed Error Code see table above for error code defi nitions Software Version Software Version Software Software Version Version Exiting Diagnostic Mode A Unplug the power cord wait 5 8 seconds then reconnect the power cord or B Turn the program knob to the start position lights buttons test Press the Cance and center button under the display simultaneously for 6 seconds To Clear Stored Error Code Press and hold the center key under the display and Cance buttons simultaneously for 3 seconds while in diagnostic test mode Factory Reset Press and hold the Temperature and Dry Leve buttons simultaneously for 6 seconds For models with Temperature Dry Level and Dry Time buttons press and hold the Dry Leve and Dry Time buttons simultaneously for 6 seconds Section 3 Dryers Electrolux Diagnostic Mode 1 Press the Cance button to enter standby mode and enable diagnostic entry 2 Within 10 seconds after pressing Cancel press any button to wake up the control 3 Within 5 seconds of wake up turn the selector knob to the far eft cycle and press and hold the Cance and the far eft button under the display simultaneously for 3 seconds to enter the diagnostic mode amp NOTE To save time at wake up the Welcome screen can be bypassed by tu
70. program knob 1 click clockwise from the start position The hot water solenoid will activate and hot water should enter through the detergent compartment 3 Turn the program knob 2 clicks from the start position The bleach water solenoid will activate and cold water should enter through the bleach compartment 4 Turn the program knob 3 clicks from the start position The bleach and the wash water solenoids will activate and cold water should enter through the softener compartment 5 Turn the program knob 4 clicks from the start position The prewash solenoid will activate and cold water should enter through the prewash compartment 6 Turn the program knob 5 clicks from the start position The door lock solenoid will deactivate and the loading door can be opened When the door is opened the drum light should turn on 7 Turn the program knob 6 clicks from the start position The door lock will activate and the washer will fill then tumble Once tumbling has started the boost heater will turn on 8 Turn the program knob 7 clicks from the start position The drain pump will activate draining out any water in the tub and the washer will operate in high spin 9 Turn the program knob 8 clicks from the start position This is a free position 10 Turn the program knob 9 clicks from the start position The control will signal the last 5 error codes with E00 being no error 11 Turn the program knob 10 clicks from the sta
71. rm convection preheat and broil do not reach over 217 of hex value within 3 minutes it causes 3 error and converts to cancel mode Gas sensor Open Gas sensor Shorted Gas sensor T1 max time error gas sensor did not obtain necessary information on time for sensor cook Oven thermal sensor Open Oven thermal sensor Shorted Preheat preset temperature not reached within 30 minutes Possibly due to heat loss around oven cavity Overheat during cooking temp reached 500 F Failure to reach designated temperature Key short error Section 6 Microwave Solution Test operation of convection heater and convection fan motor Test convection heater thermal cutout 1 Verify continuity of sensor harness and connections 2 Replace gas sensor 1 Verify continuity of sensor harness and connections 2 Replace gas sensor Recommended to replace gas sensor on the unit and verify 1 Verify continuity of sensor harness and connections 2 Replace thermal sensor 1 Verify continuity of sensor harness and connections 2 Replace thermal sensor Test convection heating element convection heater thermal cutout oven thermal sensor and wiring connections Inspect oven cavity outer casing and insulation Test temperature during cooking 1 If temperature is correct replace control 2 If over heating replace thermal sensor Test convection heating element convection heater thermal cutout oven thermal se
72. rmistor open circuit Outlet control thermistor short circuit Inlet control thermistor open circuit Solution Check for short circuit across heater relay s RL5 RL6 RL7 or L1 applied to heater relay output s 35 2 J7 1 J7 3 with cycle stopped Check for open circuit between L1 and heater relay connection s 35 1 J5 3 J7 2 If no wiring problems are found replace the Main Control Board Check heater coils and connections for short circuits to the cabinet Replace heater and or wiring and retest Check heater coils and connections for open circuits Replace heater and or wiring and retest For electric model check inlet thermal limiter for continuity If thermal limiter is open check for evidence of high temperature event and any resulting damage If no further damage is evident replace thermal limiter If no problems are found with the thermal limiter check exhaust vent system for air blockages If no problems with vent restrictions check replace high limit thermostat and retest Check outlet thermal limiter for continuity For gas model also check inlet thermal limiter for continuity If thermal limiter is open check for evidence of high temperature event and any resulting damage If no further damage is evident replace thermal limiter and retest Check heater and wiring If correct replace Main Control Board Enter function test mode and perform key test to determine which button is at fault Free the key
73. rmistor test will display pass open or shorted The fan and defrost tests will display pass or fail Once this test is invoked the test mode will stop flashing and the numbers from 1 to 10 corresponding to the chart below will appear on the HMI display 14 FZ Room Sensor 6 FZ Fan Error FZ Defrost Sensor FF Fan Error FF Room Sensor Condenser Fan Error FF Defrost Sensor 9 FZ Defrost Error For each test the HM Ambient Sensor 10 FF Defrost Error P Pass F Fail O Open Thermistor Circuit S Short Thermistor Circuit The control will display a O if the thermistor value is greater than 149 2K amp 58 F 50 C The control will display a S if the thermistor value is less than 1 34K amp 149 F 65 C Note 4 100 Run Time This test runs the sealed system 100 of the time and will automatically time out after 1 hour Cycle power OFF or enter test mode 1 5 to reset and exit this mode Note The 3 way valve position during 100 run time depends on the fresh food temperature If the fresh food temperature is satisfied the 3 way valve opens to the freezer evaporator only If it is not satisfi ed the valve opens to the fresh food evaporator and refrigerant flows through both evaporators Note 5 Toggle the State of Defrost Any time a pad on the temperature board other than the COLDER and WARMER pads is pressed the status of the defrost heaters will toggle in the following sequence il Fresh fo
74. rning the selector knob 4 Upon entering diagnostic mode all lights should turn on 5 The following steps can be cycled through by turning the selector knob clockwise Diagnostic Test Sequence Test Activated Component Operator Check LCD Row LCD Digits Electric Gas Motor Counter Clockwise Check motor function Look for drum Motor CCW CCW rotation in counter clockwise direction 2 Contact Sensor Check moisture reading Place fingers Moist Bars 1111 If contact across contact sensor and look for sensor open digit display to change from 1111 to circuit 8888 if 8888 contact Sensor short cir cuited Motor Clockwise CW Check motor function Look for drum Motor CW rotation in clockwise direction Lights buttons Lights buttons Check all buttons and lights Press all Button ID Number Test motor Test motor buttons and check for beep and but CW CW igniter ton ID number in digit display Check to see that all lights function Motor CW Motor CW Check motor and heater function HEAT1 NTC1 Outlet heater 1 heater Check outlet control thermistor value Control thermistor in digit display value Degrees F 3 10 Section 3 Dryers Diagnostic Test Sequence continued Test Activated Component Operator Check LCD Row LCD Digits Electric Gas Motor CW Motor CW Check motor and heater function HEAT2 NTC2_ Inlet control heater 1 heater Check inlet control thermistor value thermistor value heater 2 in digit disp
75. rt position Latest software version will be shown 12 If applicable turn the program knob 11 clicks from the start position This is a free position Exiting Diagnostic Mode A Unplug the power cord wait 5 8 seconds then reconnect the power cord or B Turn the program knob clockwise back to the start position Press the Cancel and far eft button under the display until the LED s stop flashing 2 f Section 2 Washing Machines Electrolux Diagnostic Mode continued Factory Reset 1 On 1 x 2 display models wake machine push the Spin Speed and Soil Selection keys simultaneously and hold until you hear a beep This is no more than 10 seconds 2 On 1 x 4 3 4 display models scroll through the Option key until you get to the Preference Selection pref Once there push the Se ect key then scroll through this menu until you get to the Reset Selection and push the Se ect key From here you have the selection of the type of reset you wish to perform Make your selection and push the Select key The machine will turn off and when woken up the part s of the program you wanted reset are now set back to factory settings Installation Cycle Before entering the Installation Cycle install cycle make sure that all articles are out of the drum the drum is empty 1 x 2 display models 1 Wake the washer up by pressing any button except the Cance button 2 Rotate the cycle knob to the Hand Wash cycle 3 Press
76. rtment 4 Turn the program knob 3 clicks from the start position The bleach and the wash water solenoids will activate and cold water should enter through the softener compartment 5 Turn the program knob 4 clicks from the start position The door lock solenoid will deactivate and the loading door can be opened 6 Turn the program knob 5 clicks from the start position The washer will fill and tumble Once tumbling has started the boost heater if so equiped will turn on 7 Turn the program knob 6 clicks from the start position The drain pump and door lock solenoid will activate To enable high spin press the Delay Start button WARNING If power is removed during this test the door can be opened To prevent injury do not put your hands inside when the tub is rotating 8 Turn the program knob 7 clicks from the start position The control will signal the last error code Exiting Diagnostic Mode There are two options for exiting the diagnostic test mode and returning the washer to normal operation A Unplug the power cord wait 5 8 seconds then reconnect the power cord or B Turn the program knob clockwise 2 or 3 clicks after the start position Press Options and Start Pause buttons simultaneously for a few seconds until wash cycle LED s appear If a situation arises where you cannot exit the diagnostic mode as described above and the bank of 5 LED s on the right end remain on regardless of program knob positi
77. s 2 12 Exiting Diagnostic MOde eseeeeeeeeeeeeeeees 2 13 To Clear Last Stored Error Codes 2 13 Affinity Diagnostic Mode ceeeeeeeeeeeeeeeeeeeeeeeteneees 2 14 Exiting Diagnostic MOde eeeeeeeeeeeeeeetees 2 14 To Clear Last Stored Error Codes 2 15 To Recall an Error Code issiria asaini 2 15 Affinity Diagnostic Mode newer models 0065 2 15 Exiting Diagnostic MOde eeeeeeeeeeeeeeeeees 2 16 To Clear Last Stored Error Codes 2 16 Electrolux Diagnostic Mode seses 2 17 Exiting Diagnostic MOde eeeeeeeeeeeeeeeeees 2 17 Factory RESCtoscsiicis niaaa aaia 2 18 Installation CyClE sssini niasin 2 18 To Clear Last Stored Error Codes 2 18 Section 3 Dryers Error Code Charts cccccccssssseeeeeeessseeeeeseesasseeeesees 3 1 Frigidaire Diagnostic Mode sseeeeeeeeeeeeees 3 5 Exiting Diagnostic MOde eeeeeeeeeeeeeeeeees 3 6 To Recall an Error Code sviiti irning 3 6 Affinity Diagnostic Mode ceeeeeeeeeeeeeeeeeeeeeenenenes 3 7 Exiting Diagnostic MOde eseeeeeeeeeeeeeeees 3 7 To Recall an Error COd cccccceesessseeeeeeeeaeeeeeeeees 3 7 Affinity Diagnostic Mode newer models 0 3 8 Diagnostic Test SEQUENCE eeeeeeeeeteteeeee seen eeeeeeeees 3 8 Exiting Diagnostic MOde eseeeeeeeeeeeeeeees 3 9 To Clear Stored Error Codes 3 9 Factory RESQtisivicicii aaa aaaea 3 9 Electrolux Diagnos
78. s open Potentiometer RR is open Potentiometer RF is open 1 Check the wiring between EOC and lock motor micro switch 2 Replace the motor door latch assembly 3 Check for binding of the latch cam lock motor rod and lock motor cam 4 Check to see if lock motor coil is open If open replace lock motor assembly 5 Lock motor continuously runs if micro switch is open replace lock motor assembly 6 F92 93 94 and 95 check oven door light switch if open replace switch 7 If all situations above do not solve problem replace EOC 1 Reset power supply to range 2 Test ESEC wiring harness Replace if defective 3 Replace UIB 4 Replace EOC 1 Reset power supply to range 2 Test ESEC wiring harness Replace if defective 3 Replace UIB 4 Replace Power Board 1 Defective ESEC harness Reseat connectors Test harness and replace if defective 2 Defective UIB Replace UIB 3 Defective Power Board Replace Power Board 1 Reset power supply to range 2 Replace Power Board 1 Reset power supply to range 2 Replace UIB 1 Defective potentiometer Test and replace if defective 2 Replace UIB Description Potentiometer LF is shorted Potentiometer LR is shorted Potentiometer RR is shorted Potentiometer RF is open Potentiometer LF is wrong value Potentiometer LR is wrong value Potentiometer RR is wrong value Potentiometer RF is wrong value Section 4 Range Solution Defective potentiome
79. spin free No Replace the motor Yes Go to step 2 Spin the tub pulley Does the tub spin free No Check the tub bearings Yes Go to step 3 Disconnect the plug from the motor and measure the resistance of the windings pin 1 to pin 2 pin 1 to pin 3 pin 2 to pin 3 All readings should be between 4 and 6 ohms If the readings are correct replace the Speed Control Board If the readings are incorrect replace the motor High motor current Remove the belt from the motor and spin the motor pulley Does the motor spin free No replace the motor Yes go to step 3 Spin the tub pulley Does the tub spin free No check the tub bearings Yes go to step 3 Disconnect the plug from the motor and measure the resistance of the windings pin 1 to 2 pin 1 to 3 pin 2 to 3 All readings should be between 4 and 6 ohms If readings are correct replace the Speed Control Board If readings are incorrect replace the motor Section 2 Washing Machines Error a i Code Description Solution B High current on inverter Refer to E56 solution E High current on motor phase Refer to E56 solution No tacho signal for 3 seconds 1 Remove the belt from the motor and spin the motor pulley Does the motor spin free No replace the motor Yes go to step 3 Spin the tub pulley Does the tub spin free No check the tub bearings Yes go to step 3 Disconnect the plug from the drive motor and measure the resistance between pi
80. tage are good replace Mini Oven Control If fault returns replace EOC Check harness connections between VSC Board and EOC Test for approximately 5VDC to VSC Board at P6 connector pins 1 and 6 If voltage is correct replace VSC Board If voltage is incorrect replace EOC Test harness connections P4 EOC and P11 Surface Element Control Board If harness checks correct failure can be caused by faulty UIB Surface Element Control Board or EOC Check harness and connectors from the EOC to Mini Oven Control Board Check for 15VDC to Mini Oven Control red and gray wires If harness and voltage are good replace Mini Oven Control If fault returns replace EOC Check resistance at room temperature and compare to RTD sensor resistance chart If resistance does not match the RTD chart replace RTD sensor probe Check sensor wiring harness between EOC and sensor probe connector Section 4 Range Error _ Code Description Solution Shorted probe connection Check resistance at room temperature if less than 500 ohms replace RTD sensor probe Check for shorted sensor probe harness between EOC and probe connector Cooktop lockout error 1 Check the wiring 2 Replace the Cooktop Lockout Control Board 3 Replace EOC EOC internal software configuration Usually this failure code would only appear if the EOC has error been replaced with an incorrect version Verify that the correct replacement part number has been instal
81. ter Test and replace if defective Replace UIB Check for moisture contamination in potentiometer Wrong value potentiometer installed Verify correct part Defective potentiometer Test and replace if defective Check for moisture contamination in potentiometer Replace UIB E013 Bad EEPROM Replace ESEC UIB Loss of display tail 0 Loss of display tail 1 Loss of keyboard tail ESEC self test failed Check connection P1 on ESEC UIB and P1 on ESEC Rotary Hi Board RR Check connection P2 on ESEC UIB and P2 on ESEC Rotary Hi Board RF Check connection J2 on ESEC UIB and J8 RF An E015 error code may indicate the ESEC UIB is not receiving a synchronization signal from the ESEC Relay Board Check first if J2 pin 5 on the ESEC Relay Board is wired to P4 pin 5 on the ESEC UIB If wiring is good and the problem is still there replace the ESEC UIB If the problem persists replace the ESEC Relay Board To deactivate showroom mode remove power and reapply Press Cance to bypass programming clock Within 60 seconds of reapplying power press Oven Light key and top oven Timer key simultaneously 4 5 Section 4 Range RESISTANCE TEMPERATURE DETECTOR SCALE RTD SENSOR TEMPERATURE F RESISTANCE OHMS 32 1 9 1000 4 0 752 5 1091 5 3 250 4 4 1453 8 9 350 5 4 1654 10 8 450 6 9 1852 13 5 550 8 2 2047 15 8 650 8 2 2237 18 5 900 13 6 2697 24 4 PROBE CIRCUIT TO CASE
82. thing that the customer can correct such as the water faucets being turned off the washer will operate normally the next time it is started In the Good models line the control signals the failure code by flashing the five indicator lights of door lock wash rinse final spin and control for the first number or letter after the E and the start indicator light for the second number or letter after the When a failure occurs the washer stops or pauses and the control beeps and flashes the five indicator lights to tell the customer that a failure has occurred To stop the flashing and beeping the customer may touch the Pause Cance button The error code remains stored in the control but once the problem is corrected it does not effect the operation of the washer If the failure is something that the customer can correct such as the water faucets being turned off the washer will operate normally the next time it is started To Recall an Error Code Wake the washer by pressing any button Wait 5 seconds Press and hold the Start and Pause Cance buttons simultaneously All LED s will go blank and after a few seconds the control will signal the stored code using audible beeps and blinking LED s The control will repeatedly signal the code as long as the Start and Pause Cancel buttons are pressed A two second pause between repeats affords you the ability to make accurate counts to identify the correct error codes amp NOTE
83. tic Mode eeeeeeeeeeeeeeees 3 10 Diagnostic Test SEQUENCE s sisisi 3 10 Exiting Diagnostic MOde eeeeeeeeeeeeeeeeees 3 11 To Clear Stored Error COdeS eeeeeseseeeeeeeeees 3 11 Factory RESCtiisiccsctsscestdecesecnecnssnccntecererteveessrnies 3 11 Installation CYC iseis 3 12 Section 4 Range Error Code Chas risona aeaa 4 1 Resistance Temperature Detector Scale s es 4 6 Oven Calibration asi szscs ssersciseaecsavectestsetsavierseseeses 4 6 1 2 Section 5 Induction Cooktop Error Cod Charts cccsscccsstecccsisernssvedeveaneussenceveavnes 5 1 Section 6 Microwave Error Code Charts cccccecssceeccesecseeeeeuseueeueeeeeeees 6 1 Section 7 Dishwasher Error Code CHANTS isisias vin deaeSeensaehdusva ducsav onesie eeenna dads 7 1 Water Test MOde ccccssssceceseceseseseesseeeeseeeeessanes 7 2 Electrolux DishWaShef s cccccssseeesseeeesseeeesaaeees 7 3 Error Code Charts ccccccccsscccceeseesssseeesseeeseaees 7 3 Relay Test Mode models EWDW6505 2 7 4 Exit Relay Test MOd cccsececeeessseeeeeeeesaeeeeeeeees 7 5 Relay Test Mode models EIDW6105 amp EIDW6305 eeceeeeeeeeees 7 5 Exit Relay Test Mode c scecccssssssseeeessessseeenenes 7 5 Section 8 Refrigerators French Door amp Iceman Error Code Charts 0 5 8 1 Temperature Resistance Chart for NTC Thermistors french door and side by side models 00008 8 2 Electrolux Icemaker Dia
84. tion may not be visible Once the Delay Time is pressed Wash Cycles will be visible Component Description Wash pump 2900 RPM 3300 RPM Set wash pump speed wash pump must be on prior to selecting W VALVE Toggle the water valve D PUMP Toggle the drain pump D VALVE Automatically cycle between opened and closed and then switches off F LAMP Turn on the floor light on select models DIAG LED Cycle through the diagnostic LED s located on the Main Control Board Toggle fan operation Apply power to lower fan wait 4 seconds and then apply power to the upper fan and damper HEATER Toggle the heater Unit must have water to toggle heater Section 7 Dishwasher Exit Relay Test Mode 1 Press Start Cancel to turn off all components 2 Press and hold Set key for a minimum of 5 seconds to reset the dishwasher Relay Test Mode models EIDW6105 and EIDW6305 For EIDW6105 and EIDW6305 models perform the following steps 1 If a wash cycle is running press Start Cance key to cancel operations and allow to drain 2 Press and hold the Hi Temp key for a minimum of 5 seconds to reset the dishwasher 3 Simultaneously press and hold Start Cancel and Heavy key for a minimum of 2 seconds 4 Press Rinse key to select relay test mode 5 Press Start Cance key to enable outputs to components while in relay test mode The door must be closed to energize component outputs While in relay test mode pressing the following keys will
85. tor runs heat source is off Drying and Cool Down LED s are lit and numbers appear in the display showing moisture sensor readings Opening the door press in on door switch plunger and placing finger on both moisture sensor bars at the same time will make the numbers decrease In controls that do not have a digital display the More Dry LED should be on Opening the door press in on Door switch plunger and placing a finger on both moisture sensor bars at the same time will make the Damp LED come on 4 Turns drive motor runs heat source is off Key test A When the Temp button is pressed all the Temp LED s should light If the Temp selector is a rotary knob and the knob is rotated there should be a key beep with each setting B When the Dryness button is pressed all the Dryness level LED s should light C When the Option or Select button is pressed all the option LED s should light D When the Start button is pressed all the cycle status LED s should light E When the Pause Cance button is pressed all the cycle status LED s should light 5 Turns drive motor runs heat source is off Coo Down LED is lit Control thermistor reading is displayed 6 Turns drive motor runs heat source is on Drying LED is lit Control thermistor reading is displayed 3 5 Section 3 Dryers Frigidaire Diagnostic Mode continued Exiting Diagnostic Mode To exit the test mode press and hold the Select and Pause Cance buttons simulta
86. uction Module Replace Generator Control Boards in the 3 zones Induction Module Check cable between Filter Board X12 and Generator Control Board X10 Replace the Filter Control Board in the 3 zones Induction Module Replace Generator Control Board in the 3 zones Induction Module Verify AC input voltage at the cooktop input Verify AC main input cables screws and jumpers Replace the Filter Board in the 3 zones Induction Module 2 Verify if the cooktop is correctly assembled 3 Change the Control Board left board Press and hold Warm key then press right front zone Power key until beep keep holding Warm then press left front 30 models Power key or left rear 36 models Power key until beep and configuration starts 1 Check the harness between Induction Module Relay Board and Control Board 2 Change the Control Board left board 3 Change the Relay Board 4 Replace the Filter Board on the Induction Module Section 5 Induction Cooktop Error o i Code Description Solution Relay check incorrect Change Relay Board as incoming power supply low voltage Verify incoming power supply to cooktop Element temperature sensor break Check all safety thermostats cook place 1 front left Element temperature sensor break cook place 2 rear left Element temperature sensor break cook place 3 center Element temperature sensor break 1 Verify element temperature sensor is correctly connected
87. ut 163K indicates the sensor may be bad and should be replaced Water fill water level or drain pump This type of fault could be temporary or permanent If this problem fault occurs the control will stop the washer and display F03 For the fill system the problem could be the inlet water is turned off To test the filling fault run the washer with no load and check if the tub fills to the proper level If the tub over fills or the water does not shut off check the pressure switch wiring and the pressure tube connection to the air dome and pressure switch If these check out the problem could be in the pressure switch or water valve If the tub fills correctly run the washer in the Drain Spin cycle to assure the pump operates and pumps out water If the pump is not running check the wiring connections If the wiring is proper and seated measure the voltage across pins 1 and 2 on the pump connector it should be about 120VAC If it is not check the voltage between pin 3 of the 4 pin connector JX and pin 3 of the 8 pin connector J11 NEUTRAL Voltage should measure about 120VAC Section 2 Washing Machines General Family Codes continued Error AN Code Description Solution Washer not advancing max time out This type of fault could be temporary or permanent If this or Speed Control problem fault occurs the control will stop the washer and display F04 To test this fault select and start the Heavy Duty cycle with the he
88. yed in relay test when drain pump is activated FL Water valve is open Displayed in relay test when water valve is activated Heat delay The control is delaying cycle to allow water temperature to rise to correct temperature in attempt to assure optimum performance hs Hall sensor The control has sensed an error with hall sensor in motor Check wiring between motor and Main Control Board If correct replace motor If error still exist replace Main Control Board Rinse aid level is low Refill rinse aid dispenser PF Power failure A power failure has occurred More than 10 of power has dropped to the unit Check house wiring rA Rinse aid The control has sensed a problem with the reed switch in the dispenser Refill the rinse aid dispenser If error still exist check wiring between dispenser and Main Control Board If not corrected replace dispenser assembly If error still exist replace Main Control Board Section 7 Dishwasher Error _ Code Description Solution Rinse aid Rinse aid reed switch in dispenser is closed reed switch Rinse aid Rinse aid reed switch in dispenser is open Refill rinse aid dispenser Replace dispenser assembly Relay triac test Relay test mode has been activated Detergent dispenser Displayed in relay test mode when detergent dispenser is activated Turbidity sensor The Main Control Board has sensed a failure in the turbidity sensor Check wiring If wiring correct replace turbidity sensor