1. TECHNICAL SPECIFICATION Model No CEP 2000 Motor AC Series 1 15 HP Max RCF 4000g Max Speed 6000 rpm Power Requirements 220 240 VAC 50Hz 3A Fused Supply UK IEC Inlet 1 6A Quick Blow Fuse DECLARATION OF CONFORMITY Manufacturers Name Capricorn Laboratory Equipment Manufacturers Address Glasshouse Studios Fryern Court Road Fordingbridge Hants SP6 ING Declares that the product Product Name Bench Top Centrifuge Model Number CEP 2000 Conforms to the following Product Specifications EMC EN6 1326 1 1997 Emissions amp Immunity EN61000 4 2 EN61000 4 3 EN55022 1998 Class B EN61000 4 4 EN61000 3 2 1995 Class A EN61000 4 5 EN61000 3 3 1995 EN61000 4 6 EN61000 4 11 Supplementary Information The product herewith complies with the requirements of the EMC Directive 89 336 EEC and carries the CE marking accordingly The product was tested in a typical configuration This declaration only applies to those centrifuges manufactured after the date shown below farh D J Prevett Technical Manager Fordingbridge Hants U K 01 November 2005 For sales or technical support please contact Capricorn Laboratory Equipment Telephone 44 0 1425 65 00 88 Fax 44 0 1425 65 00 92 e mail info capricorn labs co uk y CAPRICORN laboratory equipment Glasshouse Studios Fryern Court Road Fordingbridge e Hants e SP6 INGe UK Tel 44 0 1425 65 00 88 e Fax 44 0 1425 65 00 92 or 0700
2. y CAPRICORN laboratory equipment OPERATING INSTRUCTIONS FOR THE N 74 CAPRICORN BENCH TOP CENTRIFUGE MAINI MODEL NO CEP 2000 FOR OTHER LANGUAGES PLEASE VISIT OUR WEBSITE CES INSTRUCTIONS SONT PRESENTES DANS D AUTRES LANGUES SUR NOTRE EMPLACEMENT DE WEB DIESE ANWEISUNGEN SIND IN ANDEREN SPRACHEN IN UNSERER WEB SITE VORHANDEN ESTAS INSTRUCCIONES ESTAN PRESENTES EN OTRAS IDIOMAS EN NUESTRO WEB SITE www capricorn labs co uk y CAPRICORN laboratory equipment CAPRICORN BENCH TOP CENTRIFUGE MODEL NO CEP 2000 CAPRICORN lab oratory equipment Observation Window ATTENTION LID LOCK DELAY Lid remains locked until shortly after power is applied Access is only possible when amber indicator is illuminated Please refer to user instructions for further details IEC Power Inlet Speed Control O Knob w CINNA Y o LCD 5 gt N y SEEE E Y N INNOVA AOD OWE ONO OPERATING INSTRUCTIONS FOR THE CAPRICORN BENCH TOP CENTRIFUGE MODEL NO CEP 2000 SETTING UP WARNING THIS EQUIPMENT MUST BE EARTHED JAN 1 Insert the mains lead into the IEC power inlet at the rear of the unit 2 Plug the unit into a grounded power socket DO NOT SWITCH ON OFF is indicated by 0 ON is indicat
3. CAPRICORN 0700 2277426 e mail info capricorn labs co uk e www capricorn labs co uk
4. Y 2 Turn the TIMER knob in a clockwise direction to the required run time At this point the amber LID OPEN neon indicator will go out the red RUN neon indicator will come on and the rotor will start to rotate TIMER 30 0 27 sa sC Timer set to 15mins 217 Sg a s PLEASE NOTE if the required run time is less than 10 minutes turn the TIMER knob up to 15 minutes or more and then back to the desired setting This will ensure that the timing is accurate 3 The centrifuge is now locked and it will not be possible to open the lid until the rotor has stopped and the amber LID OPEN neon indicator has come on 4 The centrifuge may be subject to some vibration initially while the rotor accelerates through a critical stage but this should cease once it has reached a reasonable speed However if the vibration continues it is most likely that the centrifuge is unbalanced If this is the case the TIMER knob must be turned OFF and the rotor will slow down and come to a stop Once the amber LID OPEN neon indicator has come on the lid should be opened and the balance checked COMPLETION 1 Once the run has been completed the timer will switch off and the rotor will start to decelerate The red RUN neon indicator will go out and the green POWER neon indicator will remain on Once the rotor has stopped the amber LID OPEN neon indicator will come on after a s
5. ed by 1 3 Ensure that the TIMER is in the OFF position signified by the pointer being in a vertical position and that the SPEED control knob is set to 0 see Figurel Figure 1 4 Switch the power on at the rear of the unit At this point the green POWER neon indicator will come on and after a short delay the amber LID OPEN neon indicator will also come on indicating that the lid may be opened 1 Open the lid by undoing the catch on the front of the unit and lifting the lid 2 Place the sample tubes in the rotor ensuring that a The correct tubes are inserted into their corresponding places in the rotor 1f the rotor accommodates more than one size of tube b The rotor is loaded symmetrically using tubes of equal size with contents of equal weight If you are unable to balance the rotor due to an odd number of tubes fill an empty tube with water and use this as a balance This water filled tube can if necessary be used continually for this purpose see Figure 2 WARNING DO NOT RUN THE CENTRIFUGE OUT OF BALANCE YN Figure 2 3 Once the rotor is loaded close the lid and secure the catch WARNING ALWAYS ENSURE THAT THE POWER IS ON WHEN ATTEMPTING TO CLOSE THE LID A 1 Turn the SPEED control knob to the desired setting SPEEDS AT ROTOR HEAD SETTING 0 NO 00 OD Uan THE ABOVE FIGURES ARE APPROXIMATE AND INTENDED FOR GUIDANCE PURPOSES ONL
6. hort delay indicating that the lid may be opened 2 Remove the sample tubes and close the lid securing the catch on the front of the unit Once the lid has been closed the power should be turned off at the rear of the unit WARNING ALWAYS ENSURE THAT THE POWER IS ON WHEN ATTEMPTING TO CLOSE THE LID YN BREAKAGES 1 In the event of tube breakage the TIMER should be turned OFF by turning it in an anti clockwise direction back to the vertical position Once the amber LID OPEN neon indicator has come on the lid should be opened and the rotor should be removed by unscrewing the knurled nut that secures it to the unit see figure 3 The rotor should then be thoroughly cleaned and washed being careful not to allow any broken glass to cause injury BAN Knurled t nu e S Figure 3 2 After any breakages the rotor must be completely free of any glass fragments or other materials If this is not the case it will not be possible to successfully balance the rotor on future operations 3 Once the rotor has been successfully cleaned and the imbalance rectified the centrifuge may be re loaded with samples and operated in line with the procedures set out in the preceding sections In the event of any operational or technical problems please contact Capricorn Laboratory Equipment on 44 0 1425 65 00 88 and ask for Technical Support WARNING THIS EQUIPMENT MUST BE EARTHED Figure 4