1. 18 19 1 Important Safety Instructions WARNING Before Installing this product read and follow all warning notices and instructions which are included Failure to follow safety warnings and instructions can result in severe injury death or property damage Call 1 800 223 8538 or visit www usa speck pumps com for additional copies of these instructions Swim Jet Combination Fitting Manufacturers Warnings Attention Installer This manual contains important information about installation operation and safe use of this product This information should be given to the owner or operator of this equipment Most states and local codes regulate the construction installation and operation of pools and spas It is important to comply with these codes many which regulate the installation and use of this product 1 DO NOT locate this fitting in seating areas or on the back rests for such seating areas 2 This fitting should be vertically wall mounted only per manufacturer s instructions 3 All fittings and fasteners should be examined for damage or tampering before each use 4 Any missing broken or cracked fittings must be replaced before using this product Only genuine Speck replacement parts may be used 5 Acceptable fittings pipe sizes are listed on page 9 of this manual No other sizes are permitted 6 Never exceed the maximum flow rate stated on this product 7 The anti entrapment cover must be in place when using this
2. Use a Phillips head screw driver and tighten to 1 5 Nm or hand tight DO NOT use electrical or air drills NOTE The square cover part 8 will have an uneven appearance if the housing is not installed properly 4 For the air regulator assembly one 1 2 hole must be provided preferably along the vertical axis approximately 4 or minimum 2 ABOVE the water line See Figure 10 amp 11 Using the air regulator assembly gasket part 21 mark and drill two 1 4 mounting holes See Figure 10 Use two flat head 1 4 20 machines screws part 18 and two 1 4 20 nuts part 19 to mount the air regulator NOTE The flat head on the inside of the pool wall and the nut on the outside of the pool wall 5 Keep all parts not being used now in original box Store in a safe place until needed For Liner Pools Only Install the jet housing and air regulator prior to installation or replacement of the pool liner For Steel Walled Pools An optional butterfly gasket part 12A maybe purchased to replace the two 2 gaskets part 12 Increase the jet housing hole from 5 59 to 5 75 for installation See Figure 10 0 25 Air Regulator 4 9 0 50 1 70 2 Minimum E Water Level Water Level 4 Air Line 10 Pressure Housing a amp Fitting 4 N Pipe 14 Fitting 4 Suction 45 Elbow Liner amp Wall For Liner amp Fiberglass Pools Only F
3. than 30 ft CAUTION Acceptable fittings pipe sizes are listed on page 9 of this manual The 4 HP self priming plastic pump has a single phase motor with thermal overload no motor starter required The 4 HP single phase motor draws a maximum of 19 4 amps 230V The unit requires a minimum circuit of 30 amps Install a 40 amp breaker to avoid nuisance tripping when pump is turned on and off frequently The starting current of the 4 HP motor can reach up to 6 times the running currents Three phase motor draws a maximum of 12 8 amps 230V and 6 4 amps 460V The 3 5 HP single phase motor draws 13 6 amps 230V SwimJet Combination Fitting Head Loss Curve 30 257 8 27 207 PSI 0 180 200 220 240 260 280 300 Gallons per Minute Figure 2 BaduStream dimensional drawing Plumbing The BaduSteam assembly package contains all necessary parts for the installation of the unit into concrete gunite liner or fiberglass pools PLUMBING REQUIREMENTS BADUSTREAM I Pump Distance Pipe Size App
4. 5 HP self priming plastic pump single phase with thermal overload no motor starter required Optional three phase motor and control box available NOTE Normal priming pump available for installation below water level G Massage Hose with pulsator may be attached to jet nozzle NOTE The massage hose is sold separately Planning The BaduStream is normally incorporated into the original pool design However it can be added to any pool at a later date NOTE This fitting should be vertically wall mounted only per these instructions Failure to follow safety warnings and instructions can result in severe injury death or property damage The BaduStream can be installed in any size pool We suggest a minimum pool size of 7 ft wide 14 ft long and 3 2 ft deep in order to swim Most swimmers prefer 16 ft in length or longer The extra length allows the swimmer to comfortably drift back and swim up stream The BaduStream is complete with a jet housing 4 HP or 3 5 HP pump control box and optional massage hose The only additional requirement is the plumbing 4 pipe for 4 HP and 3 pipe for 3 5 HP units Consult local codes for minimum distance between pump and pool Locate pump as close to the BaduStream as practical WARNING DO NOT locate the jet housing in seating areas or on the back rests for such seating areas Use at least 4 pipe when distance between jet housing and pump is 30 ft or less and 6 for pipe runs longer
5. Concrete Pools BaduStream in Concrete or Gunite Pool Liner and or Fiberglass Pool Installation 1 Using the clamping ring part 3 as a template drill holes in the pool wall for installation The center line of the clamping ring should be 10 below the surface of the water See Figure 8 Two additional holes will need to be drilled at the 3 and 9 o clock positions for installation of the housing part 7 The four brass inserts in the clamping ring should be at the 2 4 8 and 10 o clock positions 12 Liner and or Fiberglass Pool Installation continued 2 Mount the housing part 7 and one gasket part 12 on the outside of the pool wall using two 2 screws 14 x 1 part 27 Install the screws from the inside of the pool wall through the holes drilled at 3 and 9 o clock positions See Figure 10 amp 11 3 Install the clamping ring part 3 and the gasket part 12 on the inside of the pool wall using eight 8 screws part 9 2 9 3 9 4 or 9 5 Screw lengths vary depending on the installation A Agood RTV silicone may be used with the gasket when mounting the jet housing but in most cases is not necessary Installer should decided whether or not the silicone is necessary B When installed properly the center of the housing part 7 will be 10 below the surface of the water and the hose connector 1 4 part 6 will be at the top center of the jet housing C When installing the BaduStream Cover part 8
6. Ring Air Regulator 16 x 30 x 80 Gasket Butterfly not shown 26 1 Gasket Air Control 42 x 11 x 2 Gasket Face Ring 27 2 Screw Jet Housing 14 x 1 Holder w Hose Subassembly 1 Extension Ring pre glued not shown H Fitting 1 4 A 3 A Optional Winter Cover Kit Hose 8 x3 ar Part Qty Description Hose Clamp 14 9 i j 12 1 Gasket Clamping Ring Holder Air Regulator a 9 1 4 Screw M6 x 25 Screw 1 4 20 x 1 1 2 1 Winter Plat ah Nut 1 4 20 inter Plate not shown Washer 1 4 Extension Ring Gasket 60 x 11 x2 An extension ring not shown is available upon reguest 8 Limited Warranty Speck Pumps Pool Products Inc grants solely to the original consumer purchaser Buyer of the Badu SwimJet System s the following personal non transferable and limited warranty on the following terms and conditions the Limited Warranty the Badu SwimJet System s is warranted to be free of material defects in materials or workmanship under normal use for a period of one 1 year beginning on the date of the Buyer s purchase of the Badu SwimJet System s the Limited Warranty Period Not withstanding any provisions herein to the contrary the warranties and obligations hereunder shall not in any event extend for more than two 2 years beyond the date of shipment of the Badu SwimJet System s from the factory the Limited Warranty Period The Limited Warranty is subject to each of the following additional te
7. do not permit children to use this product unless they are closely supervised at all times The wiring of the pool motor and control box should be done by a licensed electrician in accordance with local codes Be certain that the motor frame and control box are grounded Motor name plate has voltage phase amp draw and other motor information as well as wiring connection instructions BONDING As required by National Electrical Code Article 680 22 the pump motor must be electrically bonded to the pool structure reinforced bars etc by a solid copper conductor not smaller than No 8 AWG via the external copper bonding lug on the pump motor GROUNDING Permanently ground the pump motor and control box using a conductor of appropriate size Connect to the No 10 green headed ground screw provided inside the motor terminal box NOTE Do not connect to electric power supply until the unit is permanently grounded Section 8 concerns the electric motor and control box only since all other parts the pump the jet unit etc have complete and absolute separation from the pool water 4 Operation Operation Before starting the pump for the first time remove the red filler plug or strainer tank lid Fill the pump body with water until the water is level with the suction inlet Replace the red filler plug or lid hand tighten making sure the o ring is not damaged Due to the large volume of air that can be present in the vertical portion of the su
8. tested suction limiting vent system or D An automatic pump shut off system or E Disabled submerged outlets or F Suction outlets shall be reconfigured into return inlets For more information about the Virginia Graeme Baker Pool and Spa Safety Act contact the Consumer Product Safety Commission at 301 504 7908 or visit www cpsc gov WARNING Risk of Electrical Shock or Electrocution A WARNING Pool pump must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Electrical Code and all applicable local codes and ordinances Improper installation will create an electric hazard which could result in death or serious injury to pool users installers or others due to electrical shock and may also cause damage to property ee ge Always disconnect power to the pool pump at the circuit breaker before cause death servicing the pump Failure to do so could result in death or serious injury to Disconnect power before serviceman pool users or others due to electric shock working on pump or motor 2 General Description Badu Stream J The Badu SwimJet Systems from Speck Pumps are designed to be installed during the construction of your pool to create a water treadmill for anyone wanting a therapeutic and effective exercise The Badu SwimJet Systems can be installed in any type of pool large or small from gunite to vinyl liner It has no protruding parts ensuring p
9. the jet location To avoid stress on the jet housing we recommend that the BaduStream housing be encased with gunite and at least 2 to 3 inches of the plumbing stub out is covered with gunite NOTE Stress on the plumbing may crack the BaduStream housing 4 Air regulator installation should be approximately 4 or minimum 2 ABOVE the water level A To install the bottom parts of the sub assembly Air regulator holder and hose socket insert fitting connect to PVC hose Make sure the air regulator holder face is tapped over to prevent gunite from entering holder Air regulator can be located in the tile line above water line or in the deck When tiling the pool adjust the air regulator holder to proper positioning 4 or minimum 2 ABOVE the water level Place and set with hydraulic cement Install air regulator flush with the inside pool wall Drill a 1 2 hole in the tile even with the center hole on the air regulator Then tile over the air regulator holder part 17 Note Be sure NOT to plug the center hole of the air regulator holder with thinset or the tile Install the air regulator sub assembly 1 Top Part Part 22 2 Bottom Part Part 23 3 Screw M10 x 80 Part 24 6 4 Hose Ring 16 x 30 x 80 Part 25 19 a 5 Gasket Air Control 42 x 11 x2 Part 26 a flat head screw driver is reguired to tighten the screw to the holder Make sure the air regulator holder is free of l debris or t
10. to Buyer or with respect to the Badu SwimJet System s in the event of the occurrence of any one or more of the following a Any damage to the Badu SwimJet System s caused by Buyer any third party ground movement other natural forces acts of God or any other sources or causes not arising from a breach of the Limited Warranty excluding ordinary wear and tear b Any replacement modification alteration or repair of any parts or components of the Badu SwimJet System s by anyone other than Speck Pumps Pool Products Inc c Any abuse misuse accident tampering with improper installation or modification of the Badu SwimJet System s or any other actions inactions or failures to act that violate the terms and conditions of this Limited Warranty d Buyer s failure or inability to present an invoice bill receipt or other documentation clearly evidencing that the Badu SwimJet System s was installed and maintained in strict compliance with this Limited Warranty and that the claim was timely submitted within the Limited Warranty Period and or e Buyers failure to comply with the conditions and contingencies set forth in paragraph 3 below 3 The Limited Warranty is expressly conditioned and contingent upon Buyer s strict compliance with each of the following a Installation of the Badu SwimJet System s by an experienced and qualified pool industry professional and a licensed electrician who is licensed within the jurisdiction i
11. 3
12. Installation Operating and Service Manual Badu Stream Counter Swimming Unit POSL POOL PRODUCTS INCORPORATED Technical Support Address Hours Toll Free Phone Fax Website Speck Pumps 8125 Bayberry Road Jacksonville FL 32256 USA Monday Friday 8 00 am to 5 00 pm EST 800 223 8538 904 739 2626 904 737 5261 www usa speck pumps com Date of Installation Installed by Serial Number For Service Call Manufactured by Speck Pumps Jacksonville Florida USA 2012 2013 All Rights Reserved This document is subject to change without notice 2999999189 Rev 0313 KT 3 JP Table of Contents Important Safety Instructions SwimJet Combination Fitting Manufacturers Warnings General Safety Instructions General Description Installation Information Preparation Guide Planning Dimensional Drawing Plumbing Installation Concrete or Gunite Installation Liner and or Fiberglass Pool Installation Removal of Liner Ske Pump and Control Box Installation Operation Service and Maintenance Nozzle Adjustments Winterizing Trouble Shooting General Troubleshooting Problems Product Specification Replacement Parts and Exploded View Limited Warranty BaduStream I Certifications Ls s Ten CSA C22 2 No 218 1 M89 Swimming Pool Equipment AP 3e UL VGB 2008 ws LISTED 4TH2 LISTED 31B4 14 15 15 16 17 17 18
13. Y EVEN IF SPECK PUMPS POOL PRODUCTS INC HAS BEEN NOTIFIED OF THE POSSIBILITY OR LIKELIHOOD OF SUCH DAMAGES OCCURRING WHETHER SUCH LIABILITY IS BASED ON CONTRACT TORT NEGLIGENCE STRICT LIABILITY PRODUCTS LIABILITY OR OTHERWISE AND EVEN IF ANY REMEDY STATED HEREIN FAILS OF ITS ESSENTIAL PURPOSE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF SPECIAL INDIRECT INCIDENTAL EXEMPLARY OR CONSEQUENTIAL DAMAGES OR LOSS SO THE ABOVE EXCLUSIONS AND LIMITATIONS MAY NOT APPLY 6 This Limited Warranty gives the Buyer specific legal rights and the Buyer may also have other rights which vary from state to state 7 Areturn merchandise authorization RMA must be obtained from Speck Pumps Pool Products Inc before returning any product Products returned without an RMA will be refused and returned unopened to the Buyer All returned products are to be sent freight prepaid and insured for Buyer s protection to the manufacturer at 8125 Bayberry Road Jacksonville Florida 32256 USA Under no condition will products be accepted after the expiration of the Limited Warranty Period Speck Pumps Pool Products Inc shall not bear any costs or risks incurred by Buyer in shipping a defective Badu SwimJet System s to Speck Pumps Pool Products Inc or in shipping a repaired or replaced Badu SwimJet System s to Buyer 20 Notes 21 2999999189 Rev 031
14. assembly hardware is US standard thread CAUTION The center of the housing the nozzle should be 10 BELOW water level for maximum efficiency The air regulator should be approximately 4 or minimum 2 ABOVE the water level See Figure 3 CAUTION When connecting the pressure line into the pressure connection on top of the 4 HP pump Model 21 80 first install a 6 15 cm riser See Figure 3 before installing an elbow and leading the pressure line downward to the pressure connection at the jet housing This will guarantee trouble free priming of the pump Not required for the 3 5 HP Model 72 CAUTION When using 6 pipe the suction line should run to a point directly under the pump and up to the water line in 6 and finish vertical and elbow into the pump in 4 to minimize priming time See Figure 3 CAUTION In areas with soft soil conditions or with frequent earth movement a flexible section of hose should be attached to the back of the jet housing to prevent housing breakage CAUTION Throughout the entire installation make sure the plumbing connected to the BaduStream housing is well supported Unsupported plumbing will crack the housing Plumbing continued Figure 4 Figure 5 NOTE For Dual and Triple Jet Installation Increase the pipe size to 6 when jets are more than 30 ft from the pump Use 6 x 4 bushings after 4 manifold tees NOTE CHECK VALVES must be used on the discharge side of each
15. bles the swimmer to regulate the volume of water released through the jet s Turning the nozzle clockwise reduces the flow The swivel nozzle s of the BaduStream can be positioned in various directions allowing swimmers to use various swim styles Optional Accessory The Badu Swim Mirror is a perfect addition to the BaduStream this portable mirror is designed to be the perfect tool to help swimmers stay in the swim lane Optional Accessory A pulsating massage hose can be attached to one of the nozzles to enjoy a massage as advised by your physician See Figure 1 Letter G Directions for use Consult your physician before using the massage hose To reduce the risk of injury do not permit children to use the massage hose with pulsator unless they are closely supervised at all times Close the air regulator Reduce the volume of water by turning the adjustable flow nozzle s clockwise Figure 12 Under certain conditions it is possible that the current Beau Svit ioe drifts off to the left or to the right from the middle due to water bouncing off the back wall In the event that this interferes with your swimming action turn unit off for a few minutes and restart 5 Service and Maintenance Nozzle Adjustment When setting the nozzles for basic swimming it is recommended that you set the nozzles in such a way that each nozzle s intersects 4 feet away while at the same time breaks the surface 15 Nozzle Adjustme
16. completely blocked the remaining suction outlets serving the system shall have a flow rating capable of the full flow of the pump s or the specific suction system If in doubt about the rating and or head loss curve of your system consult a gualified pool or spa professional and or your respective equipment manufacturer s Also double check with your local building health authorities regarding single vs multiple drain installations etc Regularly inspect all drain covers for cracks damage and advanced weathering Ifa drain cover becomes loose cracked damaged broken or is missing close the pool or spa immediately post a notice and keep the pool or spa closed until an appropriate VGB 2008 certified drain cover is properly installed WATER VELOCITY AND FLOW RATES The maximum water velocity through drain covers is limited by some local regulations for example some state health departments limit the velocity through public pool drain covers to 1 5 feet per second This velocity limit is lower than the flow rating provided by the ASME A112 19 8 certification therefore local limit applies and must be followed Never exceed the flow rating listed on the cover even if local code does not provide a velocity limit For additional information on proper installation refer to The Association of Pool amp Spa Professionals ANSI APSP 7 Standard and the US Consumer Product Safety Commission Guidelines for Entrapment Hazard General Safety Instruction
17. ction above the waterline initial priming time may be longer than with regular pool filtration pumps It may take up to ten 10 minutes This will not damage the mechanical seal If prime is not achieved in ten 10 minutes stop the pump re fill the pump body and restart 14 Operation continued WARNING Do not use or operate the BaduStream if the anti entrapment cover is missing broken or loose To start swimming jogging or running it is suggested that the two nozzles are pointed slightly inward and slightly upward so that the water breaks approximately 4 ft in front of the BaduStream See Section 5 Nozzle Adjustment to properly adjust the nozzles Start swimming with only minimal force in arms an legs until you feel yourself drifting backwards then add force and swim upstream until a proper balance is found between force and endurance Keep in mind that this unit is designed for a balanced workout Find a pace that you can keep up for at least 20 minutes Out pacing is always possible The idea is to continue exercising for an extended period of time Consult your physician before attempting any strenuous exercise This product may not be challenging or satisfying for all levels of exercise The air regulator permits a controlled mixture of air into the water flow and creates a unique invigorating bubble bath effect It will also add additional resistance to swim against The BaduStream s adjustable flow nozzle s ena
18. he screw part 24 will not screw in Figure 7 properly Air Regulator Assembly 11 Concrete or Gunite Installation continued Note Make sure the gasket part 26 is on the back side of the bottom part part 23 against the tile This will keep the parts secure to the tile E Install the top part part 22 Snap the top part to the bottom part part 23 and turn clock wise until you hear it ratchet Turn clock wise to adjust the air 5 When installing the BaduStream Cover part 8 Use a Phillips head screw driver and tighten to 1 5 Nm or hand tight DO NOT use electrical or air drills 6 Keep all parts not being used now in original box Store in a safe place until needed An extension ring is available upon request for an application that has special needs 6 The following is a list of all parts that ARE NOT USED IN A GUNITE INSTALLATION 1 Gasket Clamping Ring Part 12 2 Bolt 4 20 x 1 1 2 Part 18 3 Nut 4 20 Part 19 4 Washer 1 4 Part 20 5 Gasket 60 x 11 x 2 Part 21 6 Screw Jet Housing 14 X 1 Part 27 Air Regulator Air Regulator Tile 1 2 Minimum 17 Water Leve 2 Minimum Water Level Air Line Concrete Wall Pressure Nozzle Housing 10 Fitting 4 Pipe Fitting 4 45 Elbow Suction Plaster Figure 8 Figure 9 Template for Installation in Gunite or
19. igure 10 Figure 11 Cutout Pool Wall for BaduStream housing BaduStream in Liner or Fiberglass Pool Removal of Liner When replacing liner or removing liner for repairs remove 4 screws part 9 1 which hold the square cover part 8 to the jet housing Remove all screws part 9 2 amp 9 3 except the top two which hold the clamping ring part 3 and gasket part 12 to the jet housing Back out the two remaining screws approximately halfway and check for any movement of the jet housing from the wall NOTE Ifthe two counter sunk screws part 27 which hold the jet housing to the wall were installed the jet housing should not move and the two remaining screws can be removed Remove one of the remaining two screws and slide the clamping ring part 3 to the side Replace all the screws before removing the last screw Remove or replace the liner Reverse the process to install liner NOTE When replacing the clamping ring and screws locate screw heads under liner make a small cut on the liner at the screw heads and push the liner over the screw head Pump and Control Box Installation CAUTION Before installing the Speck Pump read the entire pump owner s manual found in the pump box Consult local codes for minimum distance between pump and pool Locate pump as close to the pool as practical The air button works up to a maximum of 50 ft There is 50 ft of air tubing in the BaduStream box WARNING To reduce the risk of injury
20. n which the Badu SwimJet System s is installed and will be used and b Buyers operation and maintenance of the Badu SwimJet Systems in strict accordance with Speck Pumps Pool Products Inc s printed operator maintenance manuals delivered with the Badu SwimJet System s 4 DISCLAIMER THE LIMITED WARRANTY IS THE ONLY WARRANTY MADE AND IS IN LIEU OF ALL OTHER WARRANTIES AND ANY AND ALL IMPLIED WARRANTY OR CONDITION OF MERCHANTABILITY THE IMPLIED WARRANTY_AGAINST_INFRINGEMENT AND THE IMPLIED WARRANTY OR CONDITION OF FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY LIMITED IN THEIR SCOPE AND DURATION TO THE ONE YEAR TERM OF THE LIMITED WARRANTY SET FORTH HEREIN SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATION MAY NOT APPLY TO THE BUYER Limited Warranty continued 5 TO THE FULLEST EXTENT PERMITTED BY LAW IN NO EVENT SHALL SPECK PUMPS POOL PRODUCTS INC OR ITS OFFICERS DIRECTORS EMPLOYEES SHAREHOLDERS AGENTS OR REPRESENTATIVES BE LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL EXEMPLARY OR CONSEQUENTIAL DAMAGES OR LOSS INCLUDING TIME MONEY GOODWILL AND LOST PROFITS IN ANY WAY WHICH MAY ARISE HEREUNDER OR FROM THE USE OF OR INABILITY TO USE THE BADU SWIMJET SYSTEM S OR THE PERFORMANCE OR NONPERFORMANCE OF ANY OBLIGATION UNDER THIS LIMITED WARRANTY THIS PARAGRAPH THE WARRANTY DISCLAIMERS IN PARAGRAPH 4 ABOVE AND THE SOLE AND EXCLUSIVE REMEDY SET FORTH IN PARAGRAPH 1 ABOVE SHALL APPL
21. nt continued To help set the nozzles in a neutral position please follow these instructions 1 Parts required Quantity 2 4x1 PVC Pipe Quantity 2 1 1 2 MPT x 1 1 1 4 Hose Adaptor Quantity 2 Female Adapter 1 1 2 Slip x 1 1 2 FPT 2 Turn off the jet pump s 3 Insert each jet adjustment tool into jet nozzle 4 Move each jet adjustment tool toward each other until each pipe touches at water level 5 Remove jet adjustment tool Hose Adapter 1 1 2 PVC Coupling 1 1 2 PVC Pipe 1 1 2 x4 Top View 10 Figure 13 BaduStream Nozzle Adjustment Side View Perspective View Winterizing In areas subject to freezing water temperatures you should protect your equipment We recommend you purchase a winter cover kit part 2308752006K This kit includes one 1 winter plate one 1 gasket and four 4 screws Also you can protect your swimjet system as follows Drain pool until water level has dropped below the anti entrapment cover Then protect pump by removing drain plug and red filler plug or lid 16 6 Troubleshooting Frequently Asked Questions How is the current generated The pump generates up to 400 GPM coming out of two 2 jet nozzles at 27 ft per second and 36 ft per second thru
22. one 1 nozzle creating a swim current in excess of 5700 GPM measured 6 ft from the jet What size pool do need The BaduStream can be installed in any size pool However we recommend a minimum length of 14 and a minimum width of a 7 ft swimming lane What size plumbing is necessary How far away from the BaduStream can the pump be installed Use 4 plumbing up to 30 For runs longer that 30 use 6 plumbing The pump can be placed as close to the BaduStream as local codes will allow How many amps does the pump operate at 4 0 HP Maximum 19 4 amps 230 V 3 5 HP Maximum 13 6 amps 230 V What size breaker do I need You must use a 40 amp breaker for the 4 HP pump or 30 amp breaker for the 3 HP pump to avoid nuisance tripping Is the BaduStream approved Yes The BaduStream swim jet system is listed by MET and complies with UL standard 1563 Swimming Pool Equipment ASME standard ANSI ASME A112 19 8 ANSI APSP 16 2011 Standard for Swim Jet Combination Fittings and is VGB 2008 compliant Do the covers come in different colors Yes The round covers can be ordered in gray or black The square cover is only available in black or white Does the air regulator come in different colors Yes The air regulator can be ordered in black Does it matter if the housing is installed higher or lower than the manual states Yes the center of the jet must be 10 BELOW estimated water level for proper performance of
23. ool user s safety is very compact and installs at minimal cost The self contained flush mounted unit is a jet propulsion system that pumps water into the pool creating a current in excess of 5 700 gallons per minute from a single recessed jet housing Topping off the experience is the pulsating massage hose which can be attached to the jet nozzles for easy and convenient massage treatments for joints and muscles VOTE The massage hose is sold separately 3 Installation Information Preparation Guide 1 Upon receipt of the swimjet system check the cartons for damage Open each carton and check the pump s F jet housing s A and control box E for concealed damage such as cracks dents or a bent base If damage is found contact the shipper or distributor where the swimjet was purchased 2 Inspect the contents of each carton and verify that all parts are included All parts are manufactured of corrosion resistant material and combined in one single housing two or three single housings for multi jet systems which can be installed in pools of any size and shape See Figure 1 A Flush mounted Jet Housing D B Square Anti Entrapment Cover 81 x 81 4 undetectable pump suction Optional Round Cover available C Adjustable Water Flow Jet Nozzle c D Air Regulator adjusts amount of air bubbles A in water flow E Control Box with GFCI pneumatic button and tubing Figure 1 F Speck 4 HP or 3
24. product DO NOT use this product if the cover is missing or loose 8 The anti entrapment cover part 8 should be replaced within 10 installed years 9 Installation requires a Phillips screw driver Hand tighten only DO NOT use electrical or air drills 10 Consult your physician before exercising with the BaduStream or using the massage hose 11 DO NOT permit children to use this product unless they are closely supervised at all times 12 DO NOT remove any safety alert labels such as DANGER WARNING or CAUTION Keep safety alert labels in good condition and replace missing or damaged labels 13 Stay alert watch what you are doing and use common sense DO NOT use unit if you are tired and or exhausted DO NOT use unit while under the influence of drugs alcohol or any medications CAUTION DO NOT increase pump size this will increase the flow rate through the system and exceed the maximum flow rate stated on this product IMPROPER INSTALLATION OR USE OF THIS PRODUCT MAY PRESENT A RISK OF HAIR OR BODY ENTRAPMENT AND DROWNING Install this equipment in accordance with the instructions provided As the manufacturer Speck Pumps Pool Products Inc hereby certifies that their Swim Jet Combination Fitting meet or exceed the requirements of the Virginia Graeme Baker Pool amp Spa Safety Act VGB 2008 and ANSI APSP 16 2011 standards and safety regulations as set forth by the Consumer Products Safety Commission Read and then keep
25. pump Minimum 4 pipe between pump and BaduStream plumbing Figure 6 manifold BaduStream Triple Housing Installation 10 Concrete or Gunite Installation 1 Pre plumb BaduStream housings A B Install plumbing manifold or approximately 12 of 4 SCH 40 pipe to both suction and discharge fittings on the jet s housing NOTE If plumbing exceeds 30 ft between the jet housing and pump increase pipe size to 6 Install a 6 x 4 reducing bushing as close to jet housing as possible Install air control PVC hose to hose socket insert fittings part 6 Use hose clamps to secure hose to insert fittings 2 Tape the jet housing to keep concrete out of threaded inserts and out of the inside of the housing 3 Place the jet housing into reinforced steel Jet housing location is very important A Locate air control hose connector part 6 at the top and center of jet housing Air control hose connectors must be vertical or the square cover will be uneven in appearance The center of the housing the nozzle should be 10 BELOW water level for maximum efficiency Front edge of jet housing should finish even with inside gunite wall Make sure a V shaped groove is scraped out around the housing approximately 1 2 deep to allow marcite to seal against the housing DO NOT disassemble jet nozzle from housing Recheck location of the jet housing when gunite is being applied The force of the gunite may move
26. rms and conditions 1 IN THE EVENT OF ANY BREACH OF THE LIMITED WARRANTY SPECK PUMPS POOL PRODUCTS INC S ENTIRE OBLIGATION AND LIABILITY TO BUYER AND BUYER S SOLE AND EXCLUSIVE REMEDY SHALL BE AS FOLLOWS Speck Pumps Pool Products Inc will at its option either repair or replace the Badu SwimJet System s or refund to Buyer the purchase price actually paid by Buyer for the Badu SwimJet System s subject to the Limited Warranty Speck Pumps Pool Products Inc shall have no obligations under the Limited Warranty unless Buyer delivers timely written notice to Speck Pumps Pool Products Inc of the Limited Warranty claim within the Limited Warranty Period and returns the Badu SwimJet System s to Speck Pumps Pool Products Inc if requested To the fullest extent permitted by law Speck Pumps Pool Products Inc expressly disclaims any liability for and the Limited Warranty does not include or cover any labor costs or other expenses in connection with the removal transportation shipment insurance replacement repair or installation of repaired or replaced parts or for any other costs or expenses or damages to property or things including but not limited to those arising in connection with the use of or inability to use the Badu SwimJet System s 2 To the fullest extent permitted by law the Limited Warranty will be void and of no force or effect and Speck Pumps Pool Products Inc will have no liability responsibilities or obligations
27. rox flow Pressure Three Jets 2 4 HP 10 to 30 ft 4 651 GPM 16 PSI up to 50 ft 6 651 GPM 16 PSI Two Jets 4 HP 10 to 30 ft 4 380 GPM 14 PSI up to 50 ft 6 400 GPM 14 PSI One Jet 4HP 10 to 30 ft 4 217 GPM 18 PSI up to 50 ft 4 217 GPM 18 PSI One Jet 3 HP 10 to 30 ft 3 200 GPM 12 PSI up to 50 ft 4 200 GPM 12 PSI Service Valves Optional Pressure Line a Disconnect 6 pipe will allow distances of well over 50 ft 3 However control box needs to be within 50 ft for the u pneumatic on off button to function properly 8 caviaton of he pump 11 14 o L T N 3 ie A Pump Air Regulator Vertical y A Yi E Discharge Line lJ N a Water Level 4 LEJ H Check Value Optional z Horizontal Below Water Level Discharge Line jar Vertical Suction Line NOTE Valves are recommended when pump is 4 2 installed below water level NOTE Encase the jet housing and at least 2 to 3 Na no inches of the plumbing in concrete Figure 3 CAUTION All necessary screws and bolts included with the BaduStream are stainless steel ALL screw threads and threaded inserts are METRIC ONLY METRIC bolts and nuts may be used The two exceptions are the intake and delivery connections on the BaduStream and pump housing and the hardware for the air regulator assembly The intake and delivery connections on the pump model 21 80 are 4 Slip 3 Slip on pumps Model 72 The air regulator
28. s continued VGB Compliance VIRGINIA GRAEME BAKER POOL AND SPA SAFETY ACT The Virginia Graeme Baker Pool and Spa Safety Act raises certain new requirements on owners and operators of swimming pools and spas Pools or spas constructed on or after December 19 2008 shall utilize A No submerged suction outlets a gravity drainage system with ASME ANSI cover s one or more unblockable outlets or B Amultiple main drain system without isolation capability with suction outlet covers that meet ASME ANSI A112 19 8 Suction Fittings for Use in Swimming Pools Wading Pools Spas and Hot Tubs and either i A safety vacuum release system SVRS meeting ASME ANSI A112 19 17 Manufactured Safety Vacuum Release Systems SVRS for Residential and Commercial Swimming Pool Spa Hot Tub and Wading Pool Suction Systems and or ASTM F2387 Standard Specification for Manufactured Safety Vacuum Release Systems SVRS for Swimming Pools Spas and Hot Tubs or ii A properly designed and tested suction limiting vent system or iii An automatic pump shut off system Pools and spas construction prior to December 19 2008 with a single submerged suction outlet shall use a suction outlet cover that meets ASME ANSI A112 19 8 and either A Amultiple main drain system without isolation capability or a single VGB 2008 compliant unblockable or B Asafety vacuum release system SVRS meeting ASME ANSI A112 19 17 and or ASTM F2387 or C Aproperly designed and
29. these instructions for future reference General Safety Instructions The following guidelines provide information to minimize the risk of injury to users of pools spas and hot tubs WARNING TO REDUCE THE RISK OF ENTRAPMENT HAZARD v Pool and spa pumps produce high levels of suction which can pose extreme danger if a person comes in close proximity to an open pool or spa drain or if a drain cover is loose cracked broken or missing Pool and spa pumps move large volumes of water which can pose extreme danger if a person s hair comes in close proximity to a drain that is not the proper size for the pump or pumps If not an approved single unblockable outlet a minimum of two functioning suction outlets per pump must be installed Suction outlets in the same plane i e floor or wall must be installed a minimum of three 3 feet 1 meter apart as measured from center point to center point Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas If any suction outlets are located closer they shall be located on two different planes i e one on the bottom and one on the vertical wall or one each on two separate vertical walls WARNING Failure to keep suction outlet components clear of debris such as leaves dirt hair paper and other material can result in an increased potential for suction entrapment If not a single unblockable outlet in the event of one suction outlet being
30. unit Can the air regulator be placed elsewhere Yes as long as it is not continuously flooded with water Can the pump be placed below water level Yes However for best performance we recommend ordering pump for flooded suction Model 21 80 33G instead of self priming Model 21 80 33GS We recommend installing valves for ease of maintenance How far away can the air button function properly A maximum of 50 ft Consult factory for distances over 50 ft Do I need to install a motor starter No The pump has a built in thermal overload Should this be tied into my filter system No The swim jet system and the filter system should not be plumbed together as they each provide very specific functions Can l use with automated controls Yes It comes with the ability to tie into automated control systems or other switching devices Product Specification 18 Part Qty Description 1 P DN PD PD PO DYMO A RWW A MB BA A 41 AOD Face Ring Nozzle Screw Tapping 5 5 x 19 Clamping Ring Nozzle adjustable flow Se Bushing Hose Connector 1 4 Housing S Sguare Cover Screw M6 x 25 Screw M6 x 20 Screw M6 x 25 Screw M6 x 40 Part Qty Description Screw M6 x 45 22 26 1 Subassembly Complete Seat Nozzle 22 1 Top Part Air Regulator Spacer Ring 6 2 23 1 Bottom Part Air Regulator Spacer Ring 4 24 1 Screw Air Regulator M10 x 80 Gasket Clamping Ring 25 1 Hose

Download Pdf Manuals