1. Chapter 4 Chapter 5 Troubleshooting Table 5 1 lists the symptoms possible causes and recommended solutions for common problems encountered with the Alnor AVM410 Airflow Instruments TA410 If your symptom is not listed or if none of the solutions solves your problem please contact TSI Table 5 1 Troubleshooting the Alnor AVM410 Airflow Instruments TA410 Symptom Possible Causes Corrective Action No Display plug in AC adapter contacts Velocity reading Fluctuating flow Reposition probe in fluctuates less turbulent flow unstable Instrument Error Fault in instrument Factory service message appears required on instrument Remove the probe from excessive temperature immediately excessive heat can damage the sensor Operating temperature limits can be found in Appendix A Specifications 10 This page intentionally left blank Chapter 5 Appendix A Specifications Specifications are subject to change without notice Velocity Range 0 to 4000 ft min 0 to 20 m s Accuracy 2 5 of reading or 5 ft min 0 025 m s whichever is greater Resolution 1 ft min 0 01 m s Temperature Range 0 to 200 F 18 to 93 C Accuracy 0 5 F 0 3 C Resolution 0 1 F 0 1 C Instrument Temperature Range Operating Electronics 40 to 113 F 5 to 45 C Operating Probe 0 to 200 F 18 to 93 C Storage 4 to 140 F 20 to 60 C Instrument Operating Conditions Altitude up to 400
2. cleaning g This warranty is VOID if the product has been misused neglected subjected to accidental or intentional damage or is not properly installed maintained or cleaned according to the requirements of the manual Unless specifically authorized in a separate writing by Seller Seller makes no warranty with respect to and shall have no liability in connection with goods which are incorporated into other products or equipment or which are modified by any person other than Seller The foregoing is IN LIEU OF all other warranties and is subject to the LIMITATIONS stated herein NO OTHER EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE OR MERCHANTABILITY IS MADE WITH RESPECT TO SELLER S BREACH OF THE IMPLIED WARRANTY AGAINST INFRINGEMENT SAID WARRANTY IS LIMITED TO CLAIMS OF DIRECT INFRINGEMENT AND EXCLUDES CLAIMS OF CONTRIBUTORY OR INDUCED INFRINGEMENTS BUYER S EXCLUSIVE REMEDY SHALL BE THE RETURN OF THE PURCHASE PRICE DISCOUNTED FOR REASONABLE WEAR AND TEAR OR AT SELLER S OPTION REPLACEMENT OF THE GOODS WITH NON INFRINGING GOODS TO THE EXTENT PERMITTED BY LAW THE EXCLUSIVE REMEDY OF THE USER OR BUYER AND THE LIMIT OF SELLER S LIABILITY FOR ANY AND ALL LOSSES INJURIES OR DAMAGES CONCERNING THE GOODS INCLUDING CLAIMS BASED ON CONTRACT NEGLIGENCE TORT STRICT LIABILITY OR OTHERWISE SHALL BE THE RETURN OF GOODS TO SELLER AND THE REFUND OF THE PURCHASE PRICE OR AT THE OPTION OF SELLER THE REPAIR OR REPLACEME
3. 0 meters Relative humidity up to 80 RH non condensing Pollution degree 1 in accordance with IEC 664 Transient over voltage category Il External Meter Dimensions 3 3 in x 7 0 in x 1 8 in 8 4 cm x 17 8 cm x 4 4 cm Meter Weight Weight with batteries 0 6 lbs 0 27 kg Power Requirements Four AA size batteries included Temperature compensated over an air temperature range of 40 to 150 F 5 to 65 C The accuracy statement of 5 0 of reading or 5 ft min 0 025 m s whichever is greater begins at 30 ft min through 4000 ft min 0 15 m s through 20 m s Accuracy with instrument case at 77 F 25 C add uncertainty of 0 05 F F 0 03 C C for change in instrument temperature 2 3 11 ALNOR Alnor Products TSI Incorporated Visit our website www alnor com for more information USA Tel 1 800 874 2811 India Tel 91 80 67877200 China Tel 86 10 8219 7688 Singapore Tel 65 6595 6388 P N 1980575 Rev E 2014 TSI Incorporated AIRFLOW INSTRUMENTS Airflow Instruments TSI Instruments Ltd Visit our website at www airflowinstruments co uk for more information UK Tel 44 149 4 459200 France Tel 33 491 11 87 64 Germany Tel 49 241 523030 Printed in U S A
4. AIR VELOCITY METER ALNOR MODEL AVM410 AIRFLOWTM INSTRUMENTS MODEL TA410 HERNE OPERATION AND SERVICE MANUAL P N 1980575 REV E SEPTEMBER 2014 IALNOR A RrLow START SEEING THE BENEFITS OF REGISTERING TODAY Thank you for your TSI instrument purchase Occasionally TSI releases information on software updates product enhancements and new products By registering your instrument TSI will be able to send this important information to you http register tsi com As part of the registration process you will be asked for your comments on TSI products and services TSIs customer feedback program gives customers like you a way to tell us how we are doing UNDERSTANDING ACCELERATED TSI Incorporated Visit our website www tsi com for more information USA Tel 1 800 874 2811 India Tel 91 80 67877200 UK Tel 44 149 4 459200 China Tel 86 10 8219 7688 France Tel 33 4 91118764 Singapore Tel 65 6595 6388 Germany Tel 49 241523030 2013 TSI Incorporated Printed in U S A Copyright TSI Incorporated 2007 2014 All rights reserved Address TSI Incorporated 500 Cardigan Road Shoreview MN 55126 USA Fax No 651 490 3824 Limitation Of Warranty And Liability effective April 2014 For country specific terms and conditions outside of the USA please visit www tsi com Seller warrants the goods excluding software sold hereunder under normal use and service as described in th
5. NT OF THE GOODS IN THE CASE OF SOFTWARE SELLER WILL REPAIR OR REPLACE DEFECTIVE SOFTWARE OR IF UNABLE TO DO WILL REFUND THE PURCHASE PRICE OF THE SOFTWARE IN NO EVENT SHALL SELLER BE LIABLE FOR LOST PROFITS BUSINESS INTERRUPTION OR ANY SPECIAL INDIRECT CONSEQUENTIAL OR INCIDENTAL DAMAGES SELLER SHALL NOT BE RESPONSIBLE FOR INSTALLATION DISMANTLING OR REINSTALLATION COSTS OR CHARGES No Action regardless of form may be brought against Seller more than 12 months after a cause of action has accrued The goods returned under warranty to Seller s factory shall be at Buyer s risk of loss and will be returned if at all at Seller s risk of loss Buyer and all users are deemed to have accepted this LIMITATION OF WARRANTY AND LIABILITY which contains the complete and exclusive limited warraniy of Seller This LIMITATION OF WARRANTY AND LIABILITY may not be amended modified or its terms waived except by writing signed by an Officer of Seller Service Policy Knowing that inoperative or defective instruments are as detrimental to TSI as they are to our customers our service policy is designed to give prompt attention to any problems If any malfunction is discovered please contact your nearest sales office or representative or call Customer Service department at 44 0 149 4 459200 Uk 800 874 2811 USA or 1 651 490 2811 International CONTENTS CHAPTER 1 UNPACKING AND PARTS IDENTIFICATION CHAPTER 2 SETTING
6. UP ee Supplying Power to the Alnor AVM410 Airflow InStruments TA TO l sal enka ee k kek kek Installing the Batteries ee Using The Telescoping Probe pp Extending The Retracting The Probe CHAPTER 3 KAKA KA WARA Keypad FUNCTIONS CHAPTER 4 AA WARA WARA This page intentionally left blank Chapter 1 Unpacking and Parts Identification Carefully unpack the instrument and accessories from the shipping container Check the individual parts against the list of components below If anything is missing or damaged notify TSI immediately 1 Carrying case 2 Instrument This page intentionally left blank Chapter 1 Chapter 2 Setting up Supplying Power to the Alnor AVM410 Airflow Instruments TA410 The Alnor AVM410 Airflow Instruments TA410 is powered with four size AA batteries Installing the Batteries Insert four AA batteries as indicated by the diagram located on the inside of the battery compartment The Alnor AVM410 Airflow Instruments TA410 is designed to operate with either alkaline or NiMH rechargeable batteries although it will not recharge NiMH batteries Battery life will be shorter if NiMH batteries are used Carbon zinc batteries are not recommended because of the d
7. anger of battery acid leakage Using the Telescoping Probe The telescoping probe contains the velocity temperature and humidity sensors When using the probe make sure the sensor window is fully exposed and the orientation dimple is facing upstream For temperature measurements make sure that at least 3 inches 7 5 cm of the probe is in the flow to allow the temperature sensor to be in the air stream Extending the Probe To extend the probe hold the handle in one hand while pulling on the probe tip with the other hand Do not hold the cable while extending the probe as this prevents the probe from extending Retracting the Probe To retract the probe hold the handle in one hand while pulling gently on the probe cable with the other hand This page intentionally left blank Chapter 2 Chapter 3 Operation Keypad Functions ON OFF Key Press to turn the Alnor AVM410 Airflow Instruments TA410 on and off During the power sequence the display will show the following Model Number Serial Number Software Revision and Last Date Calibrated ft min m s Key Pressing this key changes the display to read air velocity C F Key Pressing this key changes the display to read temperature Changing Units To change units first put the desired measurement air velocity or temperature on the display Then press and hold the left unlabelled key for five seconds Finally use t
8. e operator s manual to be free from defects in workmanship and material for 24 months or if less the length of time specified in the operator s manual from the date of shipment to the customer This warranty period is inclusive of any statutory warranty This limited warranty is subject to the following exclusions and exceptions a Hot wire or hot film sensors used with research anemometers and certain other components when indicated in specifications are warranted for 90 days from the date of shipment Pumps are warranted for hours of operation as set forth in product or operator s manuals c Parts repaired or replaced as a result of repair services are warranted to be free from defects in workmanship and material under normal use for 90 days from the date of shipment d Seller does not provide any warranty on finished goods manufactured by others or on any fuses batteries or other consumable materials Only the original manufacturer s warranty applies e This warranty does not cover calibration requirements and seller warrants only that the instrument or product is properly calibrated at the time of its manufacture Instruments returned for calibration are not covered by this warranty f This warranty is VOID if the instrument is opened by anyone other than a factory authorized service center with the one exception where requirements set forth in the manual allow an operator to replace consumables or perform recommended
9. he AW and ENTER key to select the units This page intentionally left blank Chapter 3 Chapter 4 Maintenance The Alnor AVM410 Airflow Instruments TA410 requires very little maintenance to keep it performing well Recalibration To maintain a high degree of accuracy in your measurements we recommend that you return your Alnor AVM410 Airflow Instruments TA410 to TSI for annual recalibration Please contact one of TSI s offices or your local distributor to make service arrangements and to receive a Return Material Authorization RMA number To fill out an online RMA form visit TSI s website at http service tsi com U S amp International TSI Incorporated TSI Instruments Ltd Alnor Products Stirling Road 500 Cardigan Road Cressex Business Park Shoreview MN 55126 3996 High Wycombe Tel 800 874 2811 Bucks 651 490 2811 HP12 3ST United Kingdom Fax 651 490 3824 Tel 44 0 149 4 459200 Fax 44 0 149 4 459700 Cases If the instrument case or storage case needs cleaning wipe it off with a soft cloth and isopropyl alcohol or a mild detergent Never immerse the Alnor AVM410 Airflow Instruments TA410 If the enclosure of the Alnor AVM410 Airflow Instruments TA410 becomes broken it must be replaced immediately to prevent access to hazardous voltage Storage Remove the batteries when storing the unit for more than one month to prevent damage due to battery leakage This page intentionally left blank

Download Pdf Manuals

image

Related Search

Related Contents

Samsung Seria 5 Ultrabook™ NP540U3C-A01PL User Manual (Windows 8)  INSTALLATION MANUAL AND OPERATING INSTRUCTIONS  扱説明書 - 日本アンテナ  Samsung Galaxy Pocket Duos manual do usuário  Promate MacLine-Pro13  Dahua Technology HDW1100R surveillance camera  MODE D`EMPLOI - Kreat-box    DG3 ISLA - Portinox  ダウンロード - 株式会社クレファ  