Home

Flexiflo Quantum Nutrition Pump

image

Contents

1. Acceptable delivery is 9 to 11 mL Leave unit beeping and 4 7 Audio Volume Button While the unit beeps indicating end of dose press the audio button and note it changes audio volume from normal to somewhat muted 4 8 Occlusion Unplug unit and run on battery Start unit and pinch output to verify an occlusion is detected 4 9 Check remaining functions of selector switch They should be self explanatory 4 10 Re label Replace old PM label with the new dated per preference of the institution Optional Protect by applying clear cover label 5 Extended PM Procedure One known service issue the sense pin switch shiniest can electrically get stuck in cassette is in position Spray contact cleaner into the opening around this pin and gently pull it in and out Repeat
2. Title Ross Flexiflo Quantum DATE 7 29 2010 By Ross Abbott Labs Columbus OH DISCLAIMER THIS PROCEDURE PROVIDED AS IS AND Files Plante Q andos WITH POSSIBLE FAULTS USER MUST VERIFY BEFORE SARIE USE NEITHER PROVIDER NOR WEBSITE ASSUMES ANY RESPONSIBILITY FOR ITS USE l 2 Reference Documents FEEDING 3 Tools Fixtures Labels General Applies to the Ross Model Flexiflo Quantum also known as a Food Pump FLUSH FLEXIFLO QUANTUM Enteral Pump Manual Safety Testor Cassette See picture Scale with 0 1 gm or better resolution to support a ag Sse collection cup preferred or 5 Burette Note Don t trust the first 10ml interval at bottom Fill this with 10mL and start from there PM next due label 4 Basic PM Procedure 4 1 Physical Check line cord cassette door and case for cracks 4 2 Electrical Safety There is a small metallic stud on lower back for gnd reference The maximum leakage is 300 uA Line cord ground resistance lt 0 1 ohms 4 3 Turn unit on via the knob Listen for a normally two segment beep 4 4 Tubing Setup At this point have tubing set positioned into the scale or burette Note Ifa flush line is part of the cassette assembly pinch it off 4 5 Flow volume Setup Set Rate for 120mL hr and Set Dose 10mL Ifa flush bag is part of setup clamp it off 4 6 Turn knob to Run After 5 0 minutes the unit should stop leaving a 10mL increase

Download Pdf Manuals

image

Related Search

Related Contents

GC LABO - Comptoir Dentaire de l`Est    Synology DS110+/500GB storage server  Technical datasheet    Grandstream Networks GXV-3000 User's Manual  Manual de Instruções  Installation manual & user guide  株 主 各 位 第62期定時株主総会招集ご通知  Tascam DV-RA1000 DVD Recorder  

Copyright © All rights reserved.
Failed to retrieve file