Home

Cross line laser EK-117 Service manual

image

Contents

1. Serial Code Name Quantity 1 LV288 033 Cover ring 4 2 693 p3xp8x3 Bearing 4 3 FLG117 010 Long cover 4 FLG117 002 Settled device 5 FLG117 003 Universal ring 1 6 FLG117 009 Short cover 1 7 GB309 84 pin 3X19 8G3 1 8 GB309 84 pin 3X23 8G3 1 9 Alarm pan 1 10 Alarm board 1 11 766 vertical light 1 12 FLG117 001 Pendulum 1 13 538K horizontal light 1 2 3 Underpan set Serial Code Name Quantity 1 PCB 1 2 GB T846 1985 Stabilizing screw ST2 9x5 5 3 3 FLG117 016 Underpan 1 4 Magneticp8x5 4 5 Stabilizing screw M2 5x8 1 6 LV188 110 Lock Spring 1 7 FLG117 006 Main Pole 1 8 FLG117 005 Spindle 9 GB894 2 86 B Bar ring 1 10 FLG117 008 Lock device 1 11 GB819 85 Stabilizing screw M2 5X6 3 12 FLG117 007 centre rod 1 2 4 Housing Serial Code Name Quantity 1 FLG117 021 Keyboard 1 2 12mm bubble 1 3 FLG117 012 rubber overall 1 4 FLG117 019 Vertical glass Label 1 5 FLG117 017 Vertical glass 1 6 FLG117 015 Housing 1 7 FLG117 020 Horizontal glass Label 1 8 FLG117 018 Horizontal glass 1 3 0 Check 8 Calibration 3 1 Accuracy horizontal line 1mm Sm vertical line Imm 5m VIVO V2 H3 HO H4 3 1 3 2 Adjustment If there is the error please turn to the following operation 1 Aim the H laser diode needing adjustment to the Y of referring scale 2 Twisting the screw according to actual situation of the horizontal
2. section of 5 dry betteries Operation time Approx 6 hours Measurement 85x67x102mm Weight 0 5kg
3. Cross line laser EK 117 Service manual Suzhou Fukuda Laser Precision Instrument Co Ltd Catalogue 1 0 Function O 000 0000000000000 0000000 0000 00 0 00 0000 000000 1 2 0 Structure oo0o000000 0000000000000 000000 000000 000000000 2 DAASSEMbBIING assada anna ere Ls 22Pendulumi set sure peer ena 2 2 3 Underpani set sesos 4 24 Housing atesora CO 3 0 Check amp Calibration 0 0000000000000000000000000000000 8 Sal ACCULACY estone abat e L R 3 2 AQUSIMON es 6 cosas ap ea 0 oss Ren abu 08 4 0 Malfunctions amp Eliminations 560000000000000000000000000 10 5 0Technology parameter 000000000000000000000000000000 13 1 0 Function This instrument is equipped with the semiconductor diode with wavelength of 635nm which the laser beam has supreme visibility The instrument can make one vertical plane one horizontal plane and a down point The two plane are emitted to wall by instrument which can form two laser line plump each other Emitting directions of the laser depicted as follows o N 2 0 Structure 2 1 Assembling Serial Code Name Quantity 1 FLG117 300 Housing 1 2 FLG117 100 Pendulum set 1 3 FLG117 200 Underpan set 1 4 GB T846 1985 Stabilizing screw ST2 9x5 5 3 5 FLG117 011 Knob 1 6 GB819 85 Stabilizing screw M2X16 1 7 GB T846 1985 Stabilizing screw ST2 2x13 1 8 Alarm pan 3 2 2 Pendulum set
4. connect the panel plug with main PCB Attention If the there is a damage with panel or Main PCB It may also cause the same problem The rate is rare In that case Please contact manufacturer and look for more service 4 2 No laser emit after instrument start to work Cause DThe slope of the instrument exceeds the leveling range and instrument stays in self alarm 2 The connection between diode and main PCB has some errors Elimination DAdjust the leg screw to make the instrument back into the leveling situation 2 Take off the housing then reconnect the diode to socket of PCB Attention It will also cause the problem of no laser emitting Possibility 1s rare if there is a damage of PCB or diode In that case Please contact manufacturer and look for more service 4 3 Failure in leveling after the laser switch on Causes DThere is a rustiness caused by oxygenation on bearing surface 2 Poor connection with the self alarm ring due to the oxygenation of it s surface Elimination DTake off the housing change the rusted bearing 2 Take off the housing then take out the pendulum clean the self alarm ring with pure ethanol 5 0 Specification Line one horizontal line one vertical line Accuracy lmm 5m Self leveling range Approx 39 Working range Approx 10m indoor Approx 50m with detector Laser wavelength Laser Diode 635nmx2 Working temperature 10 C 45 C 14 F 113 F Power DC 3V
5. line 1 If the adjusting line H is the HI loosen the screw2 then tighten the screw 1 3 2 3 3 If is the H2 loosen the screw then tighten the screw 2 repeat the operation until H line matches the referring HO line 2 If the adjusting line H is the H3 loosen the screw3 then tighten the screw 4 3 2 3 3 If is the H4 loosen the screw4 then tighten the screw 3 repeat the operation until H line matches the referring HO line 3 If H laser departure from the referring VO line or the accuracy error exists between near point and far point repeat the stepland step2 until the H line matches Ho line II V laser calibration 1 Aim the H laser diode needing adjustment to the Y of referring scale 2 Twisting the screw according to actual situation of the horizontal line 1 If which adjust line is the VI loosen the screw5 then tighten the screw 5 3 2 3 3 If which adjust line is the V2 loosen the screw6 then tighten the screw 5 repeat the operation until V line matches the referring VO line 4 0 Malfunctions amp Eliminations 4 1 Failure in switching on the instrument Causes DThe voltage power of 3 section dry batteries is less than 3 2 Problem of power plug s 2 socket connect with the main PCB 3 Problem of panel plug s 9 socket connect with the main PCB Elimination DRenew the batteries 2 Take off the Housing and reconnect the power plug with main PCB 3 Take off the housing then re

Download Pdf Manuals

image

Related Search

Related Contents

Biz Box HUB「MH5K」取扱説明書  SLR6 and SLR9 Oven Range  Grundig 55 VLE 9474 SL 55" Full HD 3D compatibility Smart TV Wi-Fi Silver  Pulse Generator - - American Radio History  Aopen S110 Mini-ITX  BoConcept 22 Assembly Instruction  Johnson RSV145 User's Manual    

Copyright © All rights reserved.
Failed to retrieve file