1. AC 1xxx Series Autosampler Using HyperTerminal 6 The HyperTerminal window will then open Figure 4 fle EG Yim Cal Trecter Hep Die 913 ol l ake Conected 00139 odee Aoda SRAL CPS NUM cane E Figure 4 HyperTerminal Main Window 7 Select File Then select Properties 8 When Properties window appears Figure 5 select the Settings tab com 1 Properties mig Connect To Settings F Function aow and ctd keys act as gt C lTemnalkeys C Widows keys Emulation Bockscroll bulfer ines S00 4 I Beep three times when connecting or disconnecting Figure 5 Com Port Settings Guide to Configuring a CETAC Autosampler Using HyperTerminal 9 Press the ASCII Setup button A window for ASCII Setup will appear Figure 6 You will need to check Echo typed characters locally and Append line feeds to incoming line ends Figure 6 Press the OK button ASCII Setup RAEI ASCII Sending I Send line ends with line feeds M Echo typed characters locally Line delay fo milliseconds Character delay 0 milliseconds ASCII Receiving Append ine feeds to incoming ine ends Force incoming data to 7 bt ASCII Wap lines that exceed terminal width Lok Cancet_ Figure 6 ASCII Setup Window 10 Turn on the autosampler The HyperTerminal window Figure 4 should display an OK Guide to Configuring a CETAC 1xxx Series Autosampler Using HyperTerminal 11 The following commands will pro
2. Guide to Configuring a CETAC 1xxx Series Autosampler Using HyperTerminal Guide to Configuring a CETAC 1xxx Series Autosampler Using HyperTerminal All CETAC autosamplers can be configured using a serial communications protocol This guide explains how to configure any one of the CETAC autosamplers using the Windows HyperTerminal program Steps for configuring HyperTerminal 1 Using a serial cable connect the CETAC autosampler with the computer Plug each end of the serial cable into the COM1 port of the autosampler and the computer respectively 2 Turn on the computer must have Windows operating system and select the Accessories folder Select the HyperTerminal folder and then the HyperTerminal program 3 A window will appear Figure 1 Enter COM 1 in the name box Press the OK button 4 In the Connect To window Figure 2 in the field Connect using select COM1 Press the OK button Connection Description Fa w New Connection Enter a name and choose an icon for the connection Name com 1 icon TLIE corea Figure 1 Filename window Guide to Configuring a CETAC Autosampler Using HyperTerminal Connect To Figure 2 Connection window 5 The COM1 Properties window will appear Figure 3 Set the fields as follows Bits per second to 9600 and Flow control to None Then press the OK button COM1 Properties Figure 3 Com Port Properties Window Guide to Configuring a CET
3. The command is SETTYPE nnn where nnn is the configuration number e g SETTYPE 0 To reset the firmware to the ASX 1400 Standard configuration two characters in succession should be sent The system will respond with an OK Guide to Configuring a CETAC Autosampler Using HyperTerminal Table 1 Firmware Configurations Number Configuration 0 Standard 1400 1 Do Not Use 2 Perkin Elmer 1400 3 WearCheck 1400 4 Thermo 1400 5 CETAC APS 1650 6 Rudolph 1400 7 Standard 1600 8 Perkin Elmer 1600 9 Thermo 1600 10 Varian 1400 11 Varian 1600
4. duce various responses of the autosampler a Ver returns firmware version b Home returns all axis to home position same as power up c Tray n defines tray size and n of positions d Tube 3 4 150 tube row column down as defined by tray command e Pmp on pump on if unit has a pump f Pmp off pump off if unit has a pump g Rinse moves sipper to the rinse position extends and retracts the sipper 3 times and starts rinse pump Stays in down position with pump running up pmp off stops the pump h Down n moves the z axis down by the parameter n in mm do not run down command if sipper is not all the way up on up position or damage may occur to sipper or z axis i Up moves z axis to upper most position j ABS xxxx yyyy zzz The ABS command will move the probe position to a desired absolute position from the home position The set of x s is along the x axis numbers represent distance in 10 of millimeters The set of y s is along the y axis and is measured in tenths of millimeters The set of z s is along the z axis and is measured in millimeters With the commands listed in Step 11 it can be determined if the autosampler is communicating and functioning properly Communication and control is proven Setting Configurations The autosampler firmware contains multiple configurations Table 1 in a single firmware version There is a command that can be issued using HyperTerminal that sets the firmware configuration

Download Pdf Manuals

image

Related Search

Related Contents

ASSMANN Electronic AK-340604-000-S  TDP-SP1 DATA PROJECTOR  AMT 885, 835, 833, 823  Procedura di rilevazione Agrifigli ()  Corporate Loan Origination User Manual  User Manual - Sütron electronic GmbH  lo + destacado 222 lankoimper capa fina  Expedient User Manual – Banking Module  SoftBank 202F 取扱説明書  ダウンロード  

Copyright © All rights reserved.
Failed to retrieve file