WINDSOR 700 SERVICE MANUAL
Contents
1. eene ennemis 128 5 2 2 0024020210210 000000 nnne 131 RES Dee S OAK st tice 133 ie aoc sc WEA Ae aes 135 Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 3 USING THIS MANUAL TO LOCATE A SECTION This manual is self indexing Each function is described in a section with a large type title in the top corner in alphabetical order A list of the functions is at the end of this section THE FORMAT Each section has an introduction describing important features Note however that this is not an exhaustive description due to space limitations A flow chart is given illustrating what appears on the keypad display and suggesting your response If the display does not relate to this flow chart it will probably be because of the system status or an invalid action The displays that relate to this situation are at the end of each section under the title of NOTES PROGRAMMABLE NAMES NUMBERS The numbers and names of features such as zones users etc are programmable and will depend on the installation They are represented in this manual by the use of code letters Capital letters represent numbers i e a user number is UU representing a 2 digit number Small letters represent names and indicate the maximum number of characters i e a user name is uuuuuuuuuuuu A list of these abbreviations is at the end of this section MENUS Menus c
2. E 97 DEFINE LINE FAULT OVERRIDE 98 DEFINE LOG IN METHOD 5 3 a toten et 99 DEFINE MANAGED ette rete Pet eb mer enden 100 DEFINE NEW PIN EOCKOYT eret tenente enne einen 101 DEFINE PIN COMMAND FACILITY seen enn 102 DEEINE PIN EXPIR Y tern e nter tree 103 DEFINE PREVENT AUTO SET 5 2 04000001 104 DEFINE RESET AUTHORITY eei teinte orte eee 105 DEFINE SCHEDULEE ALARM itte tirer pre 106 eite trente eter 107 DEFINE UL EOCKODT cierta eres 108 DEFINE VERIEY ALARM rigen eoe odis 109 itii ne aee eee ees 111 POINT INPUT ISOLATE DEISOLATE eee 112 RESET NET RES TAR T ener ER HER etm eeu 114 RESET 2 SERVICE nete REC 115 SERVICEMAN SERVICEMAN SERVICEMAN PANEL ACCESS treo ert e rper etm 120 SERVICEMAN REMOTE COMMS 121 SERVICEMAN REMOTE CONFIGURATION eee 122 SEP 123 SET LINE FAULT OVERRIDE 124 STATUS DIAGNOSTIC LOG genie tei HR epe ttes ces 125 STATUS ISOLATE LISD nieto teet aa 126 STATUS POINT INPUT 2 2 40 2 000000000 000000000004 127 STATUS PRINT CONFIGURATION
3. a commercial system connected to a central station it is usual to require a service visit after an alarm By disabling full user reset it is possible to prevent the user setting the system until a serviceman has performed a reset CONFIG MENU System Select System SYSTEM Misc Sys Param Select Misc Sys Param MISC SYS PARA 1 Rst Authority Select Rst Authority MISC SYS PARAM Specify user reset capability Full user reset Press to change specified capability reset status Press X to retain specified capability Change YES or NO Returns to MISC SYS PARA 1 menu reset status 1 Enabled Disabld Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 105 DEFINE SCHEDULE ALARM The schedules not only define when a zone may be opened but also when it must be set If a zone is not set by the time the schedule closes an alarm will be generated 1f this feature 1s enabled CONFIG MENU System Select System SYSTEM Def Time Param Select Def Time Param DEF TIME PARAMse Schedule Alarm Select Schedule Alarm DEF TIME PARAMS Specify schedule timer Schedule timer Press to change displayed status alarm status Press X to retain displayed status Change YES or NO Returns to DEF TIME PARAMS menu alarm status 1 Disabld Enabled 106 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F DEFINE TAMPER RESET This facili
4. Auto Unset Restricted Unset Hide Zone on menu ATM controller Secure zone Linked zones Command Restricted Dual PIN Access Rearm delay Dormitory number Nos of Pts in D1 Nos of Pts in D2 D2 points First Delay t1 Second Delay t2 UI Address Descriptor Type Zone Access Enabled in set zone Enabld in unset zone Set Unset menu Keyswitch Card login Lobby access Point Input number Descriptor Point type Shuntable Isolatable Exemptable Displayable Verifiable Point attribute lt 70 gt lt gt Detector Test Physical address Wiring type Thresholds Auto Shunt Delay Alarm Delay Select Schedule Follow Instructions 1 From Prom Pack 2 To Prom Pack Config Number Windsor 700 Service Manual V8 4 Iss 0F Ul lockout time Auto logoff Max no of failed PINs UI lockout time New PIN lockout PIN expiry time Schedule Alarm Bell test t o Timed functions ATM times e o lo 2 eo m Prewarn connected O C 1 O C 2 C C Sounder Delay Sounder Duration Strobe Delay Strobe Duration Latent Period Prewarning Duration Mains Fail Delay Physical Address Extra O P 1 Remote Sites 2 Serial Equip 3 Comms Type 4 Event Groups 5 INOVA MPC 6 IP Ports Point Output number Physical address
5. For example To select the Set Options menu from the Function Select menu FUNCTION SELECT 1 Reset or Mute 2 Unset Options 3 Set Options Press twice and the display will scroll to show FUNCTION SELECT 3 Set Options 4 Test 5 View Status The Set Options line is now the top line of the menu Press V and the Set Options menu will be selected An alternative to the use of the A and v keys is to press the number of the required menu item This will put the item into the menu top line Note that the items shown in a menu are dependant on the status of the system and user This means that the number of items in a menu is variable and the numbering of the items is variable If in this process a mistake is made then pressing the Clear key C will usually return you to the preceding menu TO SELECT CHARACTERS Text entry is required for descriptors names These may include letters or numbers As the keypad has no letter keys available a special technique 1s used to enter descriptors For a new descriptor the display will show the following symbol The flashing cursor shows the first character position Press and a space will be selected as the first character and the cursor moves to the right If a character other than a space is required then use the A or keys to step through the character set until the one required appears The character set is as follows ABCDEFGHIJKLMNOPORSTUVW
6. Returns to POINT LIST TYPE menu if successful GROUP SHUNT Modify GROUP SHUNT Modify Select Modify AG LS EA SUR ER UR continue as for GROUP SHUNT Add DEFINE GROUP SHUNT continued overleaf Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 89 DEFINE GROUP SHUNT continued GROUP SHUNT View VIEW PT LIST G 9999999999999999 Pt III in list e 90 GROUP SHUNT View Select View Display of points in Group Shunt Use or W to scroll point list Press C to continue Returns to GROUP SHUNT menu Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F DEFINE HS SHUNT A High Security Shunt allows a group of points to be shunted with the cooperation of two users The first user must enable the shunt for a number of days The second user can then turn the shunt on and off until either the first user disables the shunt or the time specified by the first user expires CONFIG MENU System MODIFY SYSTEM e Misc Sys Param MISC SYS PARA 1 Shunt Lists POINT LIST High Security ADD HSS LIST H Enter descriptor ADD HSS LIST H hhhhhhhhhhhhhhhh Add point ADD HSS LIST H hhhhhhhhhhhhhhhh Enter Point xxx Select System Select Misc Sys Param Select Shunt Lists Select High Security HS SHUNT Add Select Add Specify descriptor Select characters see USING THE KEYPAD Select Add point Specify
7. Point Input Driven Up to 8 point inputs may control the point output Multiple inputs are ORed to provide the point input control signal and this is ANDed with the zone state and system state if these are selected Zone state gated Up to 4 states of the zone may control the point output Multiple zone conditions are ORed to provide the zone condition control signal and this is ANDed with the point input control signal if any System state gated The system condition if any is ANDed with the zone and point input conditions CONFIG MENU System Select System SYSTEM Point O P Select Point O P POINT OUTPUT Add POINT O P Add Select Add ADD POINT O P Specify point output number Enter point Enter 3 digit number Press number xxx ADD PT O P OOO Specify address of point output Physical address Enter 2 digit number conc Press Enter 2 digit number point Press CONFIGURE POINT OUTPUT Add continued overleaf Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 39 CONFIGURE POINT OUTPUT Add continued ADD PT O P OOO Enter descriptor O complete ADD PT O P OOO The point state is normally st Change YES or NO O P OOO menu menu menu point menu Momentary Monitor Latched ADD PT O P OOO Pulse delay h mm Sg x xx xx ADD PT O P OOO Pulse duration h mm ss 0 00 00 ADD PT O P link line link line Change YES link line 1
8. Select System SYSTEM Misc Sys Param Select Misc Sys Param MISC SYS PARA 1 More Params Select More Params MISC SYS PARA 2 Limit Time Adj Select Limit Time Adj LIMIT TIME ADJ Specify restriction on Time Adjust command to twice in 24H Press X to retain displayed status status Press V to change displayed status Change YES or NO status Disabled Enabled Returns to the MISC SYS PARA 2 menu Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 97 DEFINE LINE FAULT OVERRIDE This facility configures whether the Line Fault status of the communicator will affect the setting of the system The effect of Line Fault is stored by this method in the configuration data and will therefore not be lost on power interruption An alternative method of line fault override which does not affect the configuration 1s available see SET LINE FAULT OVERRIDE CONFIG MENU System SYSTEM Misc Sys Param MISC SYS PARA 1 Line Fault O R MISC SYS PARAM Line Fault status Change YES or NO status Ignored on Set Prevents Set 98 Select System Select Misc Sys Param Select Line Fault O R Specify line fault action Press X to retain displayed status Press V to change displayed status Returns to the MISC SYS PARA 1 menu Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F DEFINE LOG IN METHOD This facility is used to determine th
9. VIEW ZONE ZZ Display of number of shuntable points Max shunts nnn Display of number of isolatable points Max isolates nnn Press to continue VIEW ZONE ZZ Display of point inputs in zone Pt III in zone Use or W to scroll 1111111111111111 CONFIGURE ZONE View continued overleaf Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 71 CONFIGURE ZONE View continued VIEW ZONE ZZ Display whether this scheduled zone can be line 2 manually set or unset outside the schedule Auto Set Unset Press to continue line 2 Manual and NOT Manual and VIEW ZONE ZZ Display of Unset function Unset fct Display of Set function Set fct Press to continue on Sched expiry Unset fct 1 Set fct 1 Auto Unset Automatic Set NOT Auto Unset NOT Set VIEW ZONE ZZ Display of whether zone may only be unset once line 2 within an open window line 3 Press V to continue line 2 line 3 NOT Restricted Unset Restricted Unset in open window VIEW ZONE Display of whether zone will be displayed in the line 2 Set Unset menu Set Unset Press vV to continue line 2 Show Zone on Hide Zone on Only displayed for a Normal zone VIEW ZONE ZZ Display of whether zone is an ATM control zone line 2 Press V to continue controller line 2 NOT ATM VIEW ZONE ZZ Display whether zone is a secure zone line 2 Press V to continue line 2
10. WINDSOR 700 SERVICE MANUAL Version 8 4 GUARDALL LTD Systems Development Group PO Box 233 Chubb House Staines Road West Sunbury on Thames Middlesex TW16 7XY Manual No 320534 UNITED KINGDOM CONTENTS jn P 4 dnnnn 5 ABBREVIATIONS ia as 7 MENU TREE 2 1 2 221 sns sins sete seta 8 MENU TREE 040 10 4 1 tnn tnnt notatus tasas saneta sens 9 FUNCTIONS CLOCK SET erento e ER PF RE 10 CONFIGURE 11 CONFIGURE COPY 14 CONFIGURE 16 CONFIGURE EMERGENCY CONFIGURE eee 19 CONFIGURE ENTRY EXIT ROUTE eere 20 CONFIGURE HOLIDAY ge pee eodein 24 CONFIGURE LOBBY ACCESS treten eire etel 26 CONFIGURE OUTPUT DRIVERS eee 30 CONFIGURE POINT INPUT 5 rrt PR nro e rh tenen 32 CONFIGURE POINT OU TPUT erento ton exe teorie 39 CONFIGURE REMOTE COMMS COMMUNICATIONS TYPE 45 CONFIGURE REMOTE COMMS EVENT
11. Add continued HOLIDAY APPLIES Specify zone s to which holiday is to apply to zone ZZ Press if displayed zone required 2222222222222222 Press X if displayed zone not required Press YES or NO Returns to FUNCTION SELECT menu if successful NOTES invalid date The date entered is out of range or is already allocated as a holiday HOLIDAY Remove HOLIDAYS Remove Select Remove REMOVE HOLIDAY Confirm removal of holiday start DD mmm YY Press V to remove holiday end DD mmm YY Press X to view next holiday Press YES or NO Press C to quit without removing any holiday Returns to FUNCTION SELECT menu if successful HOLIDAY View HOLIDAYS View Select View VIEW HOLIDAY e Specify holiday starts DD mmm YY Use or W to scroll required holiday ends DD mmm YY to lines 2 and 3 Press Vv HOLIDAY APPLIES Display of zone list to zone ZZ Use or to scroll zone list ZZZZZZZZ7ZZ77Z7ZZZZ Press to continue Returns to menu Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 25 CONFIGURE LOBBY ACCESS This facility is used to configure card access through a door Typically this is for allowing access to the ATM lobby of a bank The length of data read from a card is configurable This allows a family of cards which share a common data prefix to operate the access The data prefix length may be between 1 and 19 digits The maximum of 19 digits will normally mean
12. PREWARN DURATION XXXX seconds MAINS FAIL DELAY XX minutes 56 Select System Select Responses Specify sounder delay Enter 2 digit number mins Press Specify sounder duration Enter 2 digit number mins Press 00 Continuous Specify strobe delay Enter 2 digit number mins Press Specify strobe duration Enter 2 digit number mins Press 00 Continuous Specify latent period Enter 2 digit number mins Press Specify prewarning duration Enter 4 digit number secs Press Specify period before Mains Fail alarm Enter 2 digit number mins Press Returns to MODIFY SYSTEM menu Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F CONFIGURE SCHEDULE Schedules control when zones may be unset and when they must be set Each zone may be controlled by one or more schedules If a zone is not controlled by any schedules it may be set and unset at any time Otherwise the zone may only become unset while at least one of its controlling schedules are in an open window While at least one of its controlling schedules are open but none are in an open window the zone may remain set or unset it may become set but once it is set the zone cannot become unset While all of a zone s controlling schedules are closed the zone must become or remain set it may not become or remain unset Normally the open window of a schedule starts at the earliest normal opening and ends at the l
13. System Select System SYSTEM Def Time Param Select Def Time Param DEF TIME PARAMse ATM Times Select ATM Times DEFINE ATM TIMES Specify time for PIN validation PIN entry wait Enter 2 digit number 00 to 99 Press V period xx mins Only displayed if PIN entry wait period gt 0 DEFINE ATM TIMES Specify time out for PIN re entry PIN entry period Enter 3 digit number 010 to 120 Press V XXX Seconds DEFINE ATM TIMES Specify ATM zone access time Access period Enter 2 digit number 12 to 60 Press V xx minutes DEFINE ATM TIMES Specify number of times extended time Access period may be requested repeat no xx Enter 2 digit number 01 t0 10 Press V Returns to DEF TIME PARAMS menu NOTES invalid number The selected number is out of range Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 75 DEFINE AUTO BATTERY TEST This option allows the configuration of an automatic battery test which 1s to occur at configurable times The test is then performed automatically at these times regardless of the set unset status of the system If the test fails it will not be possible to set the system configurable remote comms event will be reported Any zones which are unset unsetting or setting will be put into prewarning The test times can be configured in one of two ways Daily The test will run at the configured time on the specified day Periodically The test will run
14. T day every h mm Change YES or NO TIMED FUNCT T day every hh mm TIMED FUNCT T stat zone ZZ status Change YES or NO stat 1 in NOT in 80 If change requested from test Specify days and times for test Press A to display hours and minutes Enter 2 digit number hour Press 4 Enter 2 digit number min Press If displayed time for the day Press to change from no test Press X to retain no test If change requested from displayed time Specify days and times for test Press A if no test required Press Enter 2 digit number hour Press V Enter 2 digit number min Press Specify zones where the test will run Press X to retain displayed status Press V to change displayed status Returns to DEF TIME PARAMS menu AUTO DETECTOR TEST Periodically Select Periodically Specify days and period interval for test Press to change the displayed period Press X to retain the displayed period Repeat for all days If change requested Specify days and times for test Enter 2 digit number hour Press Enter 2 digit number min Press Specify zones where the test will run Press X to retain displayed status Press V to change displayed status Returns to DEF TIME PARAMS menu Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F DEFINE AUTO LOG OFF Define the time after which if no keys have been used on a keypad the user is autom
15. 1 verifiable not verifiable ADD PT III Specify attribute of point input ttribute Use or W to scroll required attribute ttribute to line 2 Press ttribute attribute menu 1 normal point buffer point double buffer safe shunt sla ve safe shunt mas ter Break Glass Pt If double buffer or safe shunt slave ADD PT III Specify number of control linked points Enter number of Enter 1 digit number Press control points x ADD PT III Specify control point number s Enter control Enter 3 digit number Press point number xxx Repeat for the all control points ADD PT I P III Specify if point is to be in detector test status This implies the point input is testable Detector test via a point output i e vibration detector Change YES or NO Press to change specified status Press X to retain specified status status in not in If point in detector test ADD PT III Specify point output providing stimulus Det Test driving Enter 3 digit number Press point o p xxx CONFIGURE POINT INPUT Add continued overleaf 34 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F CONFIGURE POINT INPUT Add continued ADD PT I P III Physical address cc pp ADD PT I P III Wiring type wiring menu wiring menu wiring menu UK double loop UK single loop CDN dble loop High Security ADD PT I P III zone stat ZZ 2222222222222222 Change YES or NO zone sta
16. 4 Iss 0F Guardall Ltd 27 CONFIGURE LOBBY ACCESS continued CARDS Modify LOBBY ACCESS Cards Select Cards LOBBY CARDS Modify Select Modify for CARDS Add CARDS Remove LOBBY ACCESS Cards Select Cards LOBBY CARDS Remove Select Remove REMOVE LOBBY CAR Specify card number This may apply to a family Card number xx Enter 2 digit number Press V Returns to LOBBY CARDS menu CARDS View LOBBY ACCESS Cards Select Cards LOBBY CARDS View Select View VIEW LOBBY CARD Specify lobby card number Card number xx Enter 2 digit number for card Press CONFIGURE LOBBY ACCESS continued overleaf 28 Guardall Ltd Windsor 700 Service Manual V8 4 155 0 CONFIGURE LOBBY ACCESS continued VIEW LOBBY CARD Digits in prefix Digits 1 NN Press to continue of card prefix NNNNNNNNNNNNNNNN If number of digits is 17 or more LOBBY CARD NN Digits in prefix Digits 17 NN Press to continue of card prefix NNN VIEW LOBBY CARD Keypad s which are to recognize the card UI status Press to continue at UI N Returns to LOBBY CARDS menu UI status Can be used Cannot be used Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 29 CONFIGURE OUTPUT DRIVERS Configure sounders and strobes The Mk1A hardware has the following configurable drivers Prewarning driver Closed circuit driver Open circuit driver 1 Open circuit driver 2 prewarning prewarning sounder or st
17. GROUPS 48 CONFIGURE REMOTE COMMS SERIAL EQUIPMENT 53 CONFIGURE RESPONSES 56 CONFIGURE SCHEDULE 2 rrr eth pee 57 CONFIGURE START END CONFIGURATION eee 60 CONFIGURE irat re Pri Yee Per bend ens 62 CONFIGURE eite teret etri Pee n Re Pee EHE INE URSI Re eerie steers 67 DEEINE ACPO MODBE edat ene t repete tts 74 DEFINE ATNETIMES peter P tenete erp REM ER nee E TR 75 DEFINE AUTO BATTERY 5 76 DEFINE AUTO BELE MUNTE rrr emere 78 DEFINE AUTO DETECTOR TEST erret metes 79 DEEINE 2 rm Pr Pi e dee 81 DEFINE AUTOMATIC SHUNT henan ar n E enne E E ER 82 DEFINE AUXILIARY POINT LOGGINQG eee eene 83 DEFINE BANK COMMERCIAL seen nennen 84 DEFINE BATTERY TEST ON SET rnt eet tee ener tm 85 DEFINE BELL TEST TIMEOUT cirina nennen tento tinte 86 DEFINE DURESS ALARM etre eene 87 DEFINE GROUP SHUNT roro eerte 88 DEFINE HS SHUNT encomienda an S uenn 91 DEFINE INOVA MPC CARD 5 94 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F FUNCTIONS contd DEFINE INVALID PIN eene ene nenne 95 DEFINE IP PORTS s eiecti 96 DEFINE LIMIT TIME ADJUST eere nee tnit
18. Latched type For momentary point VIEW PT O P OOO Display of delay before active Pulse delay Press to continue h mm ss n nn nrn CONFIGURE POINT OUTPUT View continued overleaf Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 43 CONFIGURE POINT OUTPUT View continued VIEW PT O P OOO Pulse duration h mm ss VIEW PT OOO Point controlled VIEW PT O P OOO Linked to Point Input III 1111111111111111 VIEW PT Zone state controlled VIEW PT O P OOO Linked to zone state function link function link see POINT OUTPUT Add VIEW PT O P OOO Depends on state of zone ZZ 2222222222222222 VIEW PT System state controlled VIEW PT O P OOO Linked to system state system state system state see POINT OUTPUT Add 44 Display of time active Press to continue If point input controlled Display of point input controlled status Press to continue Display of controlling points Use or W to scroll points list Press to continue If zone state controlled Display of zone state control status Press to continue Display of zone states linked Use or W to scroll zone states Press to continue Display of zones Use or W to scroll zone list Press to continue If system state controlled Display of system state link status Press to continue Display of system states lin
19. NOT secure zone Secure zone CONFIGURE ZONE View continued overleaf 72 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F CONFIGURE ZONE View continued Only displayed if slave zones are defined VIEW ZONE ZZ Display zones linked to this zone for set Linked zone ZZ Use or W to scroll 2222222222222222 Press V to continue VIEW ZONE ZZ Display whether selected commands are to have no line 2 1 access to this zone cmd restricted Press V to continue line 2 Zone is NOT Zone is VIEW ZONE ZZ Display whether zone is to be unset by line 2 dual PIN access dual PIN access Press V to continue line 2 Zone is NOT Zone is VIEW ZONE ZZ Display of rearm delay Rearm delay in Press to continue seconds If Autorearm configured VIEW ZONE ZZ Display whether autounshunt defined AutoUnshunt Press to continue unshunt status Returns to ZONE menu unshunt status 1 Enabled Disabled Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 73 DEFINE ACPO MODE This facility is used to clear a remote communications activation if the user logs on and unsets those zones in alarm The Central Station will for ACPO requirements ignore alarms if they are cleared within x minutes CONFIG MENU System SYSTEM Misc Sys Param MISC SYS PARA 1 More Params MISC SYS PARA 2 ACPO Tx reset ACPO TX RESET ACPO status compliant Change YES
20. Point is La Specify descriptor Select characters see USING THE KEYPAD Specify normal state of point output Press to change specified state Press X to retain state Specify type of point output Use or W to scroll required type to line 2 Press If momentary Specify delay before active Enter 1 digit number hours Press Enter 2 digit number minutes Press Enter 2 digit number seconds Press Specify active duration Enter 1 digit number hours Press Enter 2 digit number minutes Press Enter 2 digit number seconds Press Specify if point output is controlled by point input status Press to change the specified mode Press X to retain the specified mode link line 2 POINT I P DRIVEN Point IS NOT POINT I P DRIVEN CONFIGURE POINT OUTPUT Add continued overleaf 40 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F CONFIGURE POINT OUTPUT Add continued LINKED PT INPUTS Add ADD PT O P OOO Number of point inputs xxx ADD PT O P OOO Enter next point input xxx LINKED PT INPUTe Complete ADD PT O P link line link line Change YES link line 1 zone state gated NOT zone state ADD PT O P OOO function link function state Change YES or NO function link ATM Bypass walk test detector test PA test Detr test fail set zone unset zone exiting zone entering zone zone compromise pre
21. Press YES or NO Returns to TIMED FUNCTIONS menu Monday Tuesday Wednesday Thursday Friday Saturday Sunday 10 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F CONFIGURE CONCENTRATOR This facility is used to configure the concentrators which are connected to the Data Gathering Network DGN 8 Way 8 point inputs used on Concentrator which therefore uses 2 address slots 4 Way 4 point inputs used on Concentrator which therefore uses 1 address slot Monarch Guardall product a wireless Concentrator Daughter board Increases configurable outputs from 1 to 3 on a 4 way Concentrator and from 1 to 8 on an 8 way Concentrator For the configuration of the Concentrator wiring type i e End of Line etc see CONFIGURE POINT INPUT FUNCTION SELECTe Configuration Select Configuration CONFIG MENU System Select System SYSTEM Concentrator Select Concentrator CONCENTRATOR Add CONCENTRATOR Add Select Add CONCENTRATOR Specify concentrator address Enter physical Enter 2 digit number Press address xx CONCENTRATOR C Specify type of concentrator line 2 Use or W to scroll required type conc type menu to line 3 Press conc type menu line 2 conc type menu 8 way type 8 Way 4 way type 4 Way Monarch type Monarch CONFIGURE CONCENTRATOR Add continued overleaf Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 11 CONFI
22. SOAK NO POINTS AVAILABLE SOAK End Select Remove point Display of point s in soak Press V to remove soak Press X to retain soak Press C to return to menu Returns to SOAK TEST menu automatically if all Soak points are removed There are no points in soak test Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F TEST UI This facility allows the UI to be tested while the system 1s operational While in this mode the viewing angle of the LCD may be adjusted for optimum display clarity For this the keypad must be removed from the case base Note that this will not cause a tamper this is inhibited while the keypad is in self test After detaching the keypad from its base locate the potentiometer Use a small screwdriver to adjust VR1 The extremes of the display are a blank display and a display comprising black rectangles the background The optimum position of will give a display in which the displayed characters are clearly visible and the rectangles of the background have virtually disappeared When carrying out the adjustment hold the keypad in a position as near as possible to its normal operating position to ensure that the ambient lighting conditions and viewing angle are realistic lt Press 2 5 8 Q simultaneously Check display For 5 secs Display of pixel pattern 1 For 2 secs Buzzer sounds amp all LEDs light Check display For 5 secs Display of
23. User menu Select PIN User menu PIN USER MENU Comms encrypt Select Comms encrypt REMOTE SITE Select whether encrption is applicable rrrrrrrrrrrrrrrr Use or to scroll required Remote Site Encrypt status to line 2 Change YES or NO Press V to change displayed encryption status Press X to retain displayed encryption status status Press C to return to PIN USER menu disabled enabled Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 121 SERVICEMAN REMOTE CONFIGURATION A GuardStation may be used to modify the Windsor 700 configuration The existing configuration indicates which GuardStations if any may do this Remote configuration may be permitted not permitted or permitted with local permission If this last option is used the serviceman must grant permission using the procedure described here Once the procedure is complete the serviceman is logged off The GuardStation then has 30 minutes in which to commence the download Permission is rescinded following the download or after a service reset The GuardStation will be unable to perform a download if any local user is logged on or if any zone is set Note that the GuardStation may upload the configuration without local permission Configuration download Act of sending a new configuration to the Windsor 700 Configuration upload Act of reading the configuration from the Windsor 700 possibly for modification and future down
24. on the specified day at times separated by the configured period with the first test at the specified period after 00 00 midnight For example if the configured period is 07 00 the test will run at 07 00 14 00 and 21 00 CONFIG MENU System lt Select System SYSTEM Def Time Param Select Def Sys Param DEF TIME PARAMse Timed function Select Timed function TIMED FUNCTION Enter number x Specify number of timed function Enter 1 digit number 1 to 4 Press TIMED FUNCT T e Battery test Select Battery test AUTO BATTERY TEST Daily TIMED FUNCT T e Daily Select Daily TIMED FUNCT T If no test for the day day Press to change from no test no test Press X to retain no test Change YES or NO day Monday Sunday DEFINE AUTO BATTERY TEST continued overleaf 76 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F DEFINE AUTO BATTERY TEST continued TIMED FUNCT T day at hh mm TIMED FUNCT T day at hh mm Change YES or NO TIMED FUNCT T day at hh mm TIMED FUNCT T e Periodically TIMED FUNCT T day every h mm Change YES or NO TIMED FUNCT T day every hh mm Windsor 700 Service Manual V8 4 Iss 0F If change requested from no test Specify days and times for test Press A to display hours and minutes Enter 2 digit number hour Press Enter 2 digit number min Press If dis
25. or NO ACPO status Panel is ACPO Panel not ACPO 74 Select Select Select Select System Misc Sys Param More Params ACPO Mode Specify requirement for ACPO Mode Press Press to change the displayed status X to retain the displayed status Returns to MISC SYS PARAMS menu Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F DEFINE ATM TIMES The ATM bypass facility allows a zone to be temporarily unset to allow the replenishment of an ATM Each zone which protects such an ATM must be configured as an ATM bypass zone see CONFIGURE ZONES The ATM bypass is controlled either from a dedicated keypad which is only in the ATM zone or from a non dedicated keypad that has access to one or more ATM zones when any ATM control zone is set At a dedicated ATM keypad the user will enter a PIN If the PIN entry wait period is non zero the PIN has to be re entered after waiting for the specified time After replenishing the ATM the PIN is entered and Bypass Remove selected If the bypass is not removed within the access period the bypass will automatically be removed if the user is still present an alarm will be cause If the user runs out of time the bypass can be renewed up to access period repeat times by re entering the PIN and selecting Extend Bypass At a non dedicated keypad with ATM Bypass capability only the access period and access period repeat fields are used CONFIG MENU
26. or NO The Remote Site s configured are displayed Use or W to scroll the required site to line 3 Press Please telephone PPPPPPPPPPPPPPPP nnnnnnnnnnnnnnnn YES when ready Contact the Remote Site operator in order to establish that you require the commissioning When the Remote Site operator is ready Press before the remote site operator initiates the process SERVICEMAN COMMISSION REMOTE COMMS continued overleaf 116 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F SERVICEMAN COMMISSION REMOTE COMMS continued COMMISSION RC Please wait for rrrrrrrrrrrrrrrr to commission COMMISSION RC rrrrrrrrrrrrrrrr SUCCESS Press CLEAR NOTES There are no uncommissioned sites available Press CLEAR COMMISSION RC Irrrrrrrrrrrrrrr FAILED Press CLEAR FUNCTION SELECTe PIN User menu PIN USER MENU Decommission DECOMMISSION Site selected rrrrrrrrrrrrrrrr Press YES or NO The system is ready for commissioning During commissioning this will be displayed Press C if abort required The commission will also be aborted if the Serviceman is automatically logged off If the panel cover has not been removed press a numeric key occasionally to avoid being logged off The commissioning has been successful Press C to return to menu There are no Remote Sites configured or all the Remote Sites configured have already been commissioned Press C to return to menu C w
27. pixel pattern 2 Test keypad 0000000000000000 Key press should change 0 to 1 corresponding to the order 123456789 0 tamper UI VERSION Vx xx Pressing 0 should also light all LEDs and buzzer sounds for 2 secs 0000000000000000 UI VERSION Vx xx Press 2 5 8 Q simultaneously Returns to operational mode Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 135 NOTES 136 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F
28. point number Enter 3 digit number Press DEFINE HS SHUNT Add continued overleaf Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 91 DEFINE HS SHUNT Add continued ADD HSS LIST H hhhhhhhhhhhhhhhh Add point ADD HS SHUNT H hhhhhhhhhhhhhhhh Remove point ADD HS SHUNT H Remove Point III 11711113111111111 Delete YES or NO ADD HSS LIST H hhhhhhhhhhhhhhhh Quit NOTES invalid number invalid point HS SHUNT Remove Shunt REMOVE HS SHUNT hhhhhhhhhhhhhhhh Press YES or NO If HS Shunt to include more than one point Select Add point Repeat process as above If an added point requires removal Select Remove point Specify point number s Press to delete Press X to retain Press C to quit If all required points added lt Select Quit Returns to menu Number selected is out of range The point number selected is not configured or the number has already been selected HS SHUNT Remove Select Remove Shunt Specify shunt number Press to remove shunt Press X to retain shunt Returns to HS Shunt menu if successful HS SHUNT Modify Select Modify Vae SQUE actin 3 continue as for HS SHUNT Add DEFINE HS SHUNT continued overleaf 92 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F DEFINE HS SHUNT continued HS SHUNT View lt Select View VIEW PT LIST H Display of points in HS Shunt hhhhhhhhhhh
29. premises type Press to change the displayed status installation Press X to retain the displayed status Change YES or NO Returns to MISC SYS PARAMS menu premises type Commercial Bank 84 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F DEFINE BATTERY TEST ON SET This facility enables a battery test to be performed on each occassion that the system 15 set When battery test on set is configured a test will be performed whenever a user performs a set at a keypad This includes full and partial set extended and temporary set but excludes the resecuring of ATM bypass zones The test will also be performed if a remote set is performed If the test fails then the user setting or remote setting 1s prohibited The test will be performed when an automatic set on schedule expiry occurs In this case a failed test will not prevent the setting The process of battery testing causes a delay of approx 25 seconds Battery failure is declared when the measured battery voltage is below 11 7V A remote comms event can be configured to signal battery fail on set CONFIG MENU System Select System SYSTEM Misc Sys Param Select Misc Sys Param MISC SYS PARA 1 More Params Select More Params MISC SYS PARA 2 More Params Select More Params MISC SYS PARA 3 Test on set Select Test on set TEST ON SET Specify if battery test is performed on setting Battery test Pres
30. service PIN of the day is normally supplied by the Central Station This follows USER log on FUNCTION SELECTe PIN User menu Select PIN Codes PIN USER MENU Enable service Select Enable service ENTER SERVICE Select your PIN number then press V AUTHORISING CODE For security each digit will appear as an sE asterisk Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 119 SERVICEMAN PANEL ACCESS If the user who is logged on does not press any key for a configured time see CONFIGURE AUTO LOG OFF that user is logged off The serviceman may gain extra time by selecting panel access this increases the log off period by a configured multiple If even more time is needed the panel cover can be removed Provided the serviceman is logged on when the cover is removed no tamper will occur Once the cover is removed the seviceman will not be automatically logged off until it is replaced FUNCTION SELECTe PIN User menu Select PIN User menu PIN USER MENU Panel access Select Panel access Remains at the PIN USER menu 120 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F SERVICEMAN REMOTE COMMS ENCRYPTION This facility configures the system whether to encrypt the data communication with a Remote Site The encryption keys are supplied at the time of commissioning but whether the encryption is used or not depends on the configuration FUNCTION SELECTe PIN
31. than one verifiable points remains off normal when performing Clear Alarms then a verified alarm will be generated because the points are re asserted Unsetting the system will clear any existing or potential verified alarms Note The Verified Alarm Duration is accurate to the minute Therefore for example a duration of 1 minute will mean a verified alarm may be generated if the interval between verified alarms is 1 min 59 seconds CONFIG MENU System Select System SYSTEM Misc Sys Param Select Misc Sys Param MISC SYS PARA 1 More Params Select More Params MISC SYS PARA 2 More Params Select More Params DEFINE VERIFY ALARM continued overleaf Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 109 DEFINE VERIFY ALARM continued MISC SYS PARA 3 Verify Alarm VERIFY ALARM Duration xxx minutes VERIFY ALARM suppress origin status Change YES or NO status Disabld Enabled VERIFY ALARM verify bell status tamper Change YES or NO status Disabld Enabled 110 lt Select Verify Alarm Specify duration Enter 3 digit number Press Duration is in the range 001 to 255 or 000 Duration is until zone system is unset Specify whether the originating alarm events are to be communicated Press to change the displayed status Press X to retain the displayed status Specify whether bell tamper is to be a verifiab
32. type Comms type Primary Secondary CONFIGURE COMMUNICATIONS TYPE Add continued overleaf Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 45 CONFIGURE COMMUNICATIONS TYPE Add continued comm type Specify type of reporting report type Use or W to scroll required type report type to line 2 Press report type comm type report type PRIMARY Parallel SECONDARY Ademco Emul Serial For Parallel PARALLEL Specify type of communicator Communicator Use or to scroll required communicator Comm type to line 3 Press Comm type Comm type not used General o p Internet I Interdial II ADEMCO Plug on Telecom CARE Internet II NOTES No Add in COMMS TYPE menu Primary amp Secondary communications are already configured ADEMCO EMUL The ADEMCO EMULATION mode and SERIAL mode SERIAL reporting are not configurable at the keypad in the NOT available software version installed Press CLEAR COMMUNICATIONS TYPE Modify COMMS TYPE Modify Select Modify ICD continue as for COMMUNICATIONS TYPE Add CONFIGURE COMMUNICATIONS TYPE continued overleaf 46 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F CONFIGURE COMMUNICATIONS TYPE continued COMMUNICATIONS TYPE Remove COMMS TYPE Remove Select Remove REMOVE Select Primary or secondary COMMS TYPE Use or W to scroll required typ
33. warning sounder strobe zone in alarm zone in PA tamper in zone armed for entry Schedule closing settable zone If point output is linked to point input Specify linked point inputs Select Add Specify number of point inputs Enter 3 digit number Press Specify point input number Enter 3 digit number Press Repeat for all linked points Specify if point input link is complete If so Select Complete Specify if point output is controlled by zone s condition Press to change the specified mode Press X to retain the specified mode link line 2 gated If zone state gated Specify the zone states to control the point output function Press to change the specified mode Press X to retain the specified mode function state linked NOT linked CONFIGURE POINT OUTPUT Add continued overleaf Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 41 CONFIGURE POINT OUTPUT Add continued ADD PT O P OOO Specify zone s whose condition affects the zone stat ZZ point output 2222222222222222 Press to change the displayed status Change YES or NO Press X to retain the displayed status zone stat in zone NOT in zone ADD PT O P OOO Specify whether system state affects the system link point output gated Press to change the displayed status Change YES or NO Press X to change the displayed status system link system state not system
34. zone ISOLATE FUNCTION SELECTe Point control Select Point Control POINT CONTROL e Isolate point Select Isolate point ISOLATE POINT Specify point number to be isolated Enter point Enter 3 digit number Press number xxx ISOLATE PT III Display of point number for confirmation lIlITIIIIlIl1iI11111 Press to isolate Press YES or NO Press X to abort Returns to FUNCTION SELECT menu NOTES Isolate point not in menu There are no isolatable points invalid number The number selected is out of range invalid point The point number selected can not be isolated Pt is isolated The point selected is already isolated Cannot modify pt The point is configured to be not isolatable limit exceeded The zone already has the maximum permitted number of isolated points Pt is in soak A point which is already in soak test cannot be isolated POINT INPUT ISOLATE DEISOLATE continued overleaf 112 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F POINT INPUT ISOLATE DEISOLATE continued DEISOLATE FUNCTION SELECT Point Control Select Point Control POINT CONTROL e Deisolate pt Select Deisolate pt DEISOL PT III Display of isolated point s iiiiiiiiiiiiiiii Press for deisolate Press YES or NO Press X to scroll Returns to FUNCTION SELECT menu NOTES Deisolate pt not in menu There are no points isolated DEISOL PT III Deisolating the point will cause the ii
35. 0 5 81451 9 5 ol 313 Eg 21 T o lt S zlo 3 5 E 3 8 815 2 olal a a 0 2 5 9 5181 E 9 e siS 5 3 5 z amp je 5 8 o g 3 4 Quit 4 Quit 5 Quit 3 Quit Nos of days for closure Point Monitor Test NL N gt N gt FLOPS Es 2 lt 7 lt 9 7 v w oio o z io 212 21 5 21 cja T lt lt lt a s 2 s o 2 Z 5 ole o z e o z e gt gt z 3 S13 941510219 15 15 2 01 912515 4 o 2 19 DJON ol N 3 o o 9 s5 35 4 QIN oO olzlol ojo ric o oO c gt clots clots Glolelelels o a a 2 3 2 2 9 24 5 o o o 5 5 8 8 Quit First day Last day Zones Windsor 700 Service Manual V8 4 Iss 0F MENU TREE CONFIGURATION 1 System 2 Zone 3 Dormitory 4 UI Port 5 Point I P 6 Schedule 7 Emerg Reconfig 8 Copy Config 9 End Config A Add M Modify R Remove V View C Change D Delete lt gt aoo OOo CLUP Def Time Param O P drives Responses Concentrator Remote Comms Point O P Misc Sys Params E E Route Lobby Access e ol lolo 5s o wm 2 Zone number Descriptor Type route No of Isolated points No of Shunted points Auto Set
36. D Door xx HeldOp Door xx ForcOp Door xx LnFaul Door xx Tamper EVENT GROUPS Modify EVENT GROUPS Modify Select Modify ob pesti continue as for EVENT GROUPS Add EVENT GROUPS Remove EVENT GROUPS Remove Select Remove ADD GROUP Select primary or secondary 1 Primary Use or W to scroll required type 2 Secondary to line 2 Press For Parallel ADEMCO emulation REMOVE type Select group number Event Group Enter 2 digit number Press Enter No xx CONFIGURE EVENT GROUPS Remove continued overleaf Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 51 CONFIGURE EVENT GROUPS Remove continued For Serial Event Reporting REMOVE type Select group number Event Group Enter 4 digit number Press Enter No REMOVE type Display of group number for confirmation Event Group nnnn Press to remove Press YES or NO Press X to retain Returns to menu if successful EVENT GROUPS View EVENT GROUPS View Select View VIEW GROUP Select primary or secondary 1 Primary Use or W to scroll required type 2 Secondary to line 2 Press For Parallel ADEMCO emulation VIEW type Select group number Event Group Enter 2 digit number Press V Enter No xx For Serial Event Reporting VIEW type Select group number Event Group Enter 4 digit number Press V Enter No VIEW type Display of priority Group No nnnn Press to continue pr
37. ERIAL EQUIPMENT Modify continued overleaf Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 53 CONFIGURE SERIAL EQUIPMENT Modify continued If protocol is variable SERIAL PORT x Select data protocol Protocol Use or W to scroll required protocol prot menu line to line 3 Press V prot menu line prot menu line PS 006 PS 018 PS 024 SERIAL PORT x Select data rate Data rate Use or to scroll required baud rate rate menu line to line 3 Press rate menu line rate menu line 1200 2400 4800 9600 19200 38400 If not INOVA SERIAL PORT x Specify Monitor Line facility Monitor Line is Press V to change displayed status status Press X to retain displayed status Change YES or NO status ENABLED DISABLED SERIAL PORT x Specify Session time out period Session Timeout Select 2 digit hour Press xx xx hh mm Select 2 digit minute Press v If zero the session does not time out For IP network applications SERIAL PORT x Specify the Port IP address Port address Enter 4 3 digit numbers Press v 000 000 000 000 SERIAL PORT x Specify the Router IP address Router address Enter 4 3 digit numbers Press v 000 000 000 000 SERIAL PORT x Specify the subnet mask Subnet mask Enter 4 3 digit numbers Press v 000 000 000 000 Returns to menu if successful CONFIGURE SERIAL EQUIPMENT View overleaf 54 Guardall Ltd Windsor 700 Serv
38. GURE CONCENTRATOR Add continued If 8 Way or 4 Way CONCENTRATOR C Specify whether a daughter board is fitted daughter board Press to change displayed status Change YES or NO Press X to retain displayed status daughter board Extra O P UNUSED Extra O P USED Returns to CONCENTRATOR menu NOTES Add new ones not in menu The system already has a full complement of concentrators invalid number The number selected is out of range invalid address The address selected is already configured CONCENTRATOR Modify CONCENTRATOR Modify Select Modify Age ded ced continue as for CONCENTRATOR Add CONCENTRATOR Remove CONCENTRATOR Remove Select Remove REMOVE CONC Specify concentrator address Enter physical Enter 2 digit number Press address xx Returns to CONCENTRATOR menu if successful CONFIGURE CONCENTRATOR continued overleaf 12 Guardall Ltd Windsor 700 Service Manual V8 4 155 0 CONFIGURE CONCENTRATOR continued CONCENTRATOR View CONCENTRATOR View Select View CONCENTRATOR Specify concentrator address Enter physical Enter 2 digit number Press address xx VIEW CONC CC type Display of concentrator type daughter board Display of output capability Press V to continue type daughter board Type 8 Way Standard O Ps Type 4 Way Extra O P fitted Monarch Returns to CONCENTRATOR menu W
39. Group Shunt GROUP SHUNT Add ADD GS LIST G Enter Descriptor ADD GS LIST G 9999999999999999 Add point ADD GS LIST G 9999999999999999 Enter Point Select Select Select Select Select System Misc Sys Param Shunt Lists Group shunt GROUP SHUNT Add Add Specify descriptor Select characters see USING THE KEYPAD Select Add point Specify point number Enter 3 digit number Press DEFINE GROUP SHUNT Add continued overleaf 88 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F DEFINE GROUP SHUNT Add continued If Group Shunt to include more than one point ADD GS LIST G 9999999999999999 Add point 2 5 Select Add point Repeat process as above If an added point requires removal ADD GS LIST G 9999999999999999 Remove point I Select Remove point ADD GS LIST G Specify point number s Remove Point III Press to delete 1111111111111111 Press X to retain Delete YES or NO Press C to quit If all required points added ADD GS LIST G 9999999999999999 Quit lt Select Quit Returns to menu NOTES invalid number Number selected is out of range invalid point The point number selected is not configured or the number has already been selected GROUP SHUNT Remove GROUP SHUNT Remove lt Select Remove REMOVE GS LIST G gggggggggggggggg Press to remove list Press YES or NO Press X to retain list
40. HUNT UNSHUNT in the User Manual FUNCTION SELECTe View status Select View status VIEW STATUS Shunt Isolates Select Shunt Isolates SHUNT ISOLATES e Isolate list Select Isolate list ISOLATE LIST Display of isolate list Pt III isolated Use A or W to scroll 1 172 1221 bgp 1 Press C to return to menu NOTES Shunt Isolates not in menu No isolatable points 126 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F STATUS POINT INPUT CALIBRATE This facility displays the current state of a point input and allows the point to be calibrated The point input circuitry in a concentrator and the connected detector form a resistor network The state of the point input depends upon the voltage across this network The point status facility displays the deviation of the present voltage from normal Typical deviations for each of the three basic concentrators are No End of Line Normal 0 Alarm 32 Tamper device 22 End of Line Normal 0 Alarm 19 Tamper device 38 High Security Normal 0 Alarm 22 Tamper device 44 If the status display is showing a small deviation when the point input is normal it is possible to recalibrate the point This may be required if contacts are dirty the circuit wiring has a small resistance or to accommodate end of line resistor tolerances Calibration is particularly impo
41. If setting of any of these zones would cause an alarm then none of the zones are set including this one CONFIG MENU Zone Select Zone ZONE Add Select Add zone ADD ZONE Specify zone number Enter number xx Enter 2 digit number Press ADD ZONE ZZ Specify zone descriptor Enter descriptor Select characters see USING THE KEYPAD O complete ADD ZONE ZZ Specify zone type Define type Use or W to scroll required type zone type menu to line 3 Press zone type menu zone type menu Normal Special secure ATM Bypass CONFIGURE ZONE Add continued overleaf Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 67 CONFIGURE ZONE Add continued ADD ZONE ZZ Specify Entry Exit route Specify entry Enter 2 digit number Press exit route xx 0 no route MAX NUMBER OF Specify maximum number of isolatable points isolated points Enter 3 digit number Press XXX MAX NUMBER OF Specify maximum number of shuntable points shunted points Enter 3 digit number Press XXX ADD ZONE ZZ Specify if this scheduled zone can be manually line 2 set or unset outside the schedule Auto Set Unset Press X to retain displayed status Change YES or NO Press V to change displayed status line 2 Manual and NOT Manual and ADD ZONE ZZ Specify if zone is to be automatically set line 2 when a schedule expires Schedule expiry Press X to retain di
42. Normal Point State Input Driven Zone State Gated System State Gated Duress Alarm Work Late Type Reset Authority Bank Commercial Shunt List Line Fault Override Auto Bell Mute Login Method More Parameters E E Route number Descriptor Points on E E E E Times Timed set Verifiable lt gt UK double loop UK single loop CDN double loop High security 1 Mod Schedule 2 Delete Schedule Keep old user table Guardall Ltd lt gt Auto Logoff time PIN lockout time L PIN change time Schedule timer Bell test timeout PIN entry wait period Access period Access period repeat Port number Communicator Baud Rate Monitor Line Session Timeout Port Address Router Address Subnet Mask Not used Detector Test Battery Test 1 2 3 4 Comms Test Not used ChubbCOM V 25bis Hayes HDX Windsor Modem WModem HDX Direct General O P Internet 1 1 Parallel 2 Ademco Emul Interdial 2 Ademco Plug On Primary nz Secondary MasterCard Enter ID Duress type Duress confirmation Duress text Unset Zone Duress Fixed Increment Full User Reset Bank Commercial Telecom ABC Internet 2 Event Group number
43. OGGING Defines the logging of Auxiliary Point activation to be when the system is set when unset or for when both set and unset Logging can be further controlled on a per point basis see POINT INPUT ADD Log entries are limited to once a minute CONFIG MENU System Select System SYSTEM Misc Sys Param Select Misc Sys Param MISC SYS PARA 1 More Params Select More Params MISC SYS PARA 2 Aux Pt Logging Select Aux Pt Logging AUX PT LOGGING Specify system wide the behaviour of auxiliary 1 When Set point logging 2 When Unset 3 Always Returns to the MISC SYS PARAMS menu Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 83 DEFINE BANK COMMERCIAL There are differences in alarm clearing in the bank and commercial sectors This option allows the system to be tailored for use in these two sectors If the system is configured as a commercial system performing the Clear Alarms function also unsets the affected zones If the system is configured as a bank system any prewarning conditions will automatically be cleared when the master logs on and all clears and mutes apply to the zones to which the user has access irrespective of the keypad access CONFIG MENU System Select System SYSTEM Misc Sys Param Select Misc Sys Param MISC SYS PARA 1 Bank Commerce Select Bank Commerce MISC SYS PARAM Specify type of installation
44. Point ADD PT I P III Specify function of Control Point Ctl Pt action Use or W to scroll required function function to line 3 Press YES to accept function Clear Alarms Partial Set Partial Unset If not a PA point ADD PT I P III Specify if point is to be shuntable shunt state Press to change displayed status Change YES or NO Press X to retain displayed status shunt state shuntable not shuntable ADD PT I P III Specify if point is to be isolatable isolate state Press to change displayed status Change YES or NO Press X to retain displayed status isolate state isolatable not isolatable ADD PT I P III Specify if point is to be exemptable exempt state Press to change displayed status Change YES or NO Press X to retain displayed status exempt state exemptable not exemptable CONFIGURE POINT INPUT Add continued overleaf Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 33 CONFIGURE POINT INPUT Add continued ADD PT I P III Specify if point is to be displayable display state Press to change displayed status Change YES or NO Press X to retain displayed status display state displayable not displayable For NA and 24HR points only ADD PT I P III Specify if point is to be verifiable verify state Press to change displayed status Change YES or NO Press X to retain displayed status verify state
45. RINT CONFIG e Stop printout 128 Select View status Select Historic log Select Print config PRINT CONFIGURATION Start Select Start printout The configuration printout will commence PRINT CONFIGURATION Stop Select Stop printout The configuration printout will halt Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F PRINT CONFIGURATION ABBREVIATIONS FORM A POINT INPUTS FLAGS S Shuntable I Isolatable E Exemptable L Log Signal Point Activations V Verifiable A Auto shuntable ATTRIBUTE BUF Buffer point DBF Double Buffer point SSM Safe Shunt Master SSS Safe Shunt Slave BGP Break Glass Point Call Point LOGICAL FUNCTION ANDO Outputs anded ANDI Inputs anded ORO Outputs ored ORI Inputs ored FORM B ZONES TYPE NORM Normal zone ATM ATM zone FLAGS ST Zone is set TA Timer Alarm on schedule expiry AS Auto set on schedule expiry EU Emergency Unset applicable AU Auto unset on schedule open window MS Monitor shunt facility RU Restricted unset during schedule open window MC Manaul operation plus automatic set unset AT ATM Control zone SU Shown on set unset menu 2U Dual PIN access SE Secure zone RC Restricted Command access FORM E ENTRY EXIT ROUTES ATTRIBUTES ENT Entry point EXT Exit point IN Entry route point OUT Exit route point IBF Entry route buffer point OBF Exit route buffer point FORM F KEYPADS T
46. System messages Zone messages Point messages 5 Not used 1 High Security 2 Group Shunt Aux Pt Logging zx Keypad Alarm BS4737 Mode PIN Commands ACPO TX Reset Managed Reset Auto Shunt Limit Time Adjust More Parameters On entry is point On exit is point H Descriptor Add Point Remove Point Descriptor Add Point Remove Point 1 Verify Alarm 2 Test on set 3 Tamper reset Not used Route Point Entry Exit Point Buffer Point Night Alarm 1 Night Alarm 2 Night Alarm 3 Earliest Early Opening Earliest Norm Opening Latest Normal Opening Latest Normal Closing Latest Late Working Descriptor 24 Hour PA Silent PA Day Silent Battery Monitor Signalling Control Point 24 Hour Warning 24 Hour Alarm CLOCK SET This facility is used to set the date and time FUNCTION SELECTe Time functions Select Time functions TIME FUNCTIONS Set clock Select Set clock SET CLOCK Specify date Date Enter 2 digits day Press dd mm yyyy Enter 2 digits month Press Enter 4 digits year Press SET CLOCK Specify time Time Enter 2 digits hour Press hh mm Enter 2 digits minute Press SET CLOCK Display of date and time for confirmation day Press to update the clock DD MMM YY HH MM Press X to abort
47. Test Select Test TEST MENU Other tests Select Other tests MONITOR Start POINT MON TESTe Start test Select Start test The detector states will now be recorded The test may be run for as long as required Returns to POINT MON TEST full menu MONITOR View POINT MON 5 View test Select View test POINT MON TEST Specify detector point number Select point for Enter 3 digit number Press view xxx VIEW POINT III Display of detector status iiiiiiiiiiiiiiii Use or W to scroll list point status Press C to return to menu test log point status 1 test log point normal no changes point off normal was normal point in tamper was off normal was in tamper all states used TEST MONITOR continued overleaf Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 131 132 TEST MONITOR continued NOTES invalid number The number selected is out of range invalid point The number selected is not configured or the point may not be placed in monitor MONITOR Stop POINT MON 5 Stop test Select Stop test Returns to POINT MON TEST menu Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F TEST SOAK The soak test facility 1s used to assess the performance of detectors following repair or installation A detector under soak test does not participate in the alarm system so off normal and tamper conditio
48. There are a large number of error messages associated with this display The error must be corrected Press C to return to menu The configuration is too large for the storage device which is fitted on the Control Unit PCB The device will require substitution or the configuration must be reduced Press C to return to menu The configuration data has filled the storage device to the extent that the space remaining to hold user data is restricted and the number of users will hence be limited as displayed Guardall Ltd 61 CONFIGURE UI This facility enables the programming of devices which connect to the User Interface Network UIN Disabled in a set zone The display will be blank Pressing a key will un blank the display and the user may log in Disabled in an unset zone The display will be blank but in this instance attempted use by pressing a key will have no effect This facility 1s primarily intended for ATM bypass A card reader can be attached to one or more keypads This can be used to grant access to an ATM lobby when a valid card is swiped see CONFIGURE LOBBY ACCESS for how to set up valid cards or alternatively to provide access card log on see the User Manual for how to setup valid user cards When configuring a keypad you must specify whether a lobby card reader is attached If so you must specify which point output is linked to the lobby door strike and for how long the door must be opened when a card is swip
49. XYZabcdefghijklmnopqrstuvwxyz 0123456789 Press V to select the character and the cursor moves to the right for the next selection If a mistake is made in the selection then press C to move the cursor back The process is completed when 16 characters have been entered or alternatively when all the required characters have been entered then pressing 0 on the keypad will store the descriptor and complete the descriptor entry In modifying an existing descriptor the process 1s similar Each character will blink in turn to show that character may be changed 6 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F ABBREVIATIONS CCCCCCCCCCCCCCCC E G 9999999999999999 H hhhhhhhhhhhhhhhh Deh eT IG 0111111 K kkkkkkkkkkkkkkkk OOOOOOOOOOOOOOOO R rrrrrrrrrrrrrrrr SS SSSSSSSSSSSSSSSS T UU uuuuuuuuuuuuuuuu ZZ 2222222222222222 DD mmm YY DD MM HH MM 55 5 UI Windsor 700 Service Manual V8 4 Iss 0F Concentrator address Concentrator descriptor Entry Exit route number Entry Exit route descriptor Shunt group number Shunt Group descriptor High Security Shunt group number High Security Shunt group descriptor Point Input number Point Input descriptor Keypad number Keypad descriptor Point Output number Point Output descriptor Remote Site number Remote Site descriptor Schedule number Schedule descripto
50. YPE UIC Normal MIM Mimic PNT Printer Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 129 PRINT CONFIGURATION ABBREVIATIONS continued FLAGS KSW Keyswitch ENS Enabled when controllable zones set DSU Disabled if controllable zone s unset ATM HNG Removable DAT EKY CHK LOB Card reader attached for ATM lobby access CRD Card reader attached for login SUN Display set unset menu FORM G CONCENTRATORS TYPE CDN Canadian EOL End of line HSC High security MON Monarch NEOL end of line FORM H POINT OUTPUTS CONTROL FLAGS MOM Momentary LTH Latched NOF Mormally off TRG Triggered PNT Point gated AND Point inputs anded CNT Linked point input to be counted OU Un ATM ATM zone bypassed WTS Walk test DTS Detector test PTS PA test SET Set zones UNS Unset zones EXT Exiting zones ENT Entering zones CMP Compromised zones PWD Prewarning SND Sounders STB Strobes ALM Alarms PAA PA alarms TAM Tampers ARM Armed zones SDC Schedule closing LNF Line Fault MNF Mains Fail ADF Auto Detector test fail ZIS Zone is settable 130 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F TEST MONITOR The monitor test when started records henceforth any changes of state that the detector makes The changes may then be reviewed by using the view facility in the test Monitor test does not affect the operation of the detector in the alarm system FUNCTION SELECTe
51. as pressed to abort commissioning Press C to return to menu DECOMMISSION REMOTE COMMS Select PIN User menu Select Decommission The Remote Site s commissioned are displayed Use or W to scroll the required site to line 3 Press SERVICEMAN COMMISSION REMOTE COMMS continued overleaf Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 117 SERVICEMAN COMMISSION REMOTE COMMS continued NOTES Remote There are no Remote Sites commissioned communications not commissioned Press CLEAR Press C to return to menu 118 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F SERVICEMAN LOG ON To log on as a serviceman your access must first be established by a user log on This will be a customer s representative with an authority level of Master Manager or User 1 During initial commissioning or when a system fault has ocurred there are no user PINs defined To allow access a default user PIN 1111 is enabled Use the default user PIN to log on select the Enable Service option as shown below and then use the default service PIN 974072 to gain access in the service role NOTE The service PIN changes with the date The default service Pin is based on the default date Therefore setting the date to the current date will disable the default service PIN After a configuration has been downloaded from the PROM Pack the default service PIN will change in accordance with the configuration details The
52. atest normal opening the schedule is then open until the latest normal closing it is then closed until the following earliest normal opening The early open feature may be used to bring the start of the open window forward see User Manual The start of the open window cannot be bought forward any further than the earliest early opening Similarly late working delays the when the schedule becomes shut This can not be delayed any further that the latest late working If all five times above are set to zero the schedule is closed all day SCHEDULE Add CONFIG MENU Schedule Select Schedule SCHEDULE S Specify schedule number SSSSSSSSSSSSSSSS Use A or W to scroll number Press v Press YES to select SCHEDULE S Specify zone s to be controlled by Controls zone ZZ the schedule 2222227222222222 Press V to select zone Press YES or NO Press X to reject zone Repeat for all zones Repeat for each day SCHEDULE 5 Specify Earliest early opening day Enter 2 digit number hour Press Earliest early Enter 2 digit number min Press Opening If not required the time must be set to the same as normal opening day Monday Tuesday Wednesday Thursday Friday Saturday Sunday CONFIGURE SCHEDULE Add continued overleaf Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 57 CONFIGURE SCHEDULE Add continued SCHEDULE S day Earliest normal opening SCHEDULE S d
53. atically logged off and any incomplete operation aborted CONFIG MENU System Select System SYSTEM Def Time Param Select Def Time Param DEF TIME PARAMse Auto logoff Select Auto logoff DEF TIME PARAMS Specify automatic log off period Auto log off Enter 3 digit number secs Press 4 after secs Returns to DEF TIME PARAMS menu Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 81 DEFINE AUTOMATIC SHUNT This facility will present the user with the Clear Alarms command following log on if the users area is in alarm condition Three attempts at Clear Alarms may then be made whereupon if point s are still off normal shunts will be automatically applied The shunts are conditional viz the points are configured as shuntable the shunt total is within limit the user has zone access for the applicable zones CONFIG MENU System lt Select System SYSTEM Misc Sys Param Select Misc Sys Param MISC SYS PARA 1 More Params Select More Params MISC SYS PARA 2 Auto Shunt Select Auto Shunt AUTOMATIC SHUNT Specify requirement for Automatic Shunt status Press to change the displayed status Change YES or NO Press X to retain the displayed status Returns to MISC SYS PARAMS menu status Enabled Disabld 82 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F DEFINE AUXILIARY POINT L
54. ay Latest normal opening SCHEDULE S day Latest normal closing xx xx SCHEDULE S day Latest late working SCHEDULE S Enter descriptor NOTES SCHEDULE ERROR Overlapping time settings Specify Earliest normal opening Enter 2 digit number hour Press 4 Enter 2 digit number min Press Specify Latest normal opening Enter 2 digit number hour Press 4 Enter 2 digit number min Press 4 Specify Latest normal closing Enter 2 digit number hour Press 4 Enter 2 digit number min Press Specify Latest late working Enter 2 digit number hour Press 4 Enter 2 digit number min Press 4 If not required the time must be set to the same as normal closing The above repeats for each day to be specified Specify schedule descriptor Select characters see USING THE KEYPAD Returns to Log On A mistake in data entry For example Latest Normal Opening is before Earliest Normal Opening CONFIGURE SCHEDULE continued overleaf 58 Guardall Ltd Windsor 700 Service Manual V8 4 155 0 CONFIGURE SCHEDULE continued CONFIG MENU Schedule SCHEDULE 5 SSSSSSSSSSSSSSSS Press YES to select SCHEDULE Modify CONFIG MENU Schedule SCHEDULE S SSSSSSSSSSSSSSSS Press YES to select SCHEDULE Remove Windsor 700 Service Manual V8 4 Iss 0F SCHEDULE Modify Select Schedule Specify schedule Use
55. be blanked In this state in unset zone pressing a key will have no effect Change YES or NO Press to change displayed status Press X to retain displayed status unset line 1 UI Enabled when UI Disabled when UI PORT K Specify whether UI has set unset menu line 2 Press to change displayed status Press X to retain displayed status Change YES or NO line 2 No Set Uns Menu Set Unset Menu UI PORT K Specify whether UI has keyswitch key message Press to change displayed status Change YES or NO Press X to retain displayed status key message UI with key no keyswitch UI PORT K Specify whether UI has card reader for log on Card Login Press to change displayed status line 3 Press X to retain displayed status Change YES or NO line 3 Disabled Enabled CONFIGURE UI Add continued overleaf Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 63 CONFIGURE UI Add continued UI PORT K Specify whether UI has lobby access Lobby access Press to change displayed status access status Press X to retain displayed status Change YES or NO If you select this then card reader log on is disabled access status Disabled Enabled If lobby access enabled UI PORT K Specify point output controlling lobby door Door strike on Enter 3 digit number Press point xxx UI PORT K Specify duration of point output 0 to 998 Door open for Ente
56. d 99 DEFINE MANAGED RESET This facility is used in a system where full user reset is disabled By configuring Managed Reset the user may reset alarms following confirmation from the Central Station When the user logs on following an alarm the alarm log is presented followed by the Managed Reset display This presents the user with a contact number for the Central Station and a code number The user should contact the Central Station and quote the code number In response the user will be given a 5 digit PIN code and should log on with this PIN This will reset the system CONFIG MENU System Select System SYSTEM Misc Sys Param Select Misc Sys Param MISC SYS PARA 1 More Params Select More Params MISC SYS PARA 2 Managed Reset Select Managed Reset MANAGED RESET Specify if Managed Reset facility should be status available Change YES or NO Press X to retain displayed status Press V to change displayed status status Disabled Enabled MANAGED RESET If Managed Reset facility enabled Contact info Select up to 16 characters see USING THE KEYPAD Numbers may be entered directly Configurable text may be used to store for example a telephone number to contact Returns to MISC SYS PARAMS menu 100 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F DEFINE NEW PIN LOCKOUT Once a PIN has been changed it may not be changed again for a per
57. dsor 700 Service Manual V8 4 Iss 0F DEFINE VERIFY ALARM Define the verified alarm function This function will cause a special Verified Alarm event to be reported only when two verifiable alarm states occur within a configured time of each other This is designed to reduce false alarms Verified alarms are restricted to Night Alarm points 24 hour points Bell tamper and Entry Route Timeout The configured time between states for a verified event known as the Verified Alarm Duration is from 1 to 255 minutes A duration of zero is used to configure a duration until the system or zone is next unset When using verified alarms the individual alarm events of the involved points may be suppressed This applies to the following events 24H 24Hr Alarm in any zone 24H1 24H8 24Hr Alarm in Zone Z NA Night Alarm in any zone NAI NA8 Night Alarm in Zone Z P001 P250 Alarm on point I The following events are used to report the verified alarm VAS Verified Alarm system VALI VALS8 Verified Alarm in Zone Z The VAS event is caused by two verifiable sensors in any part of the system going into alarm within the Verified Alarm Duration of each other The VALn event is caused by two verifiable sensors which are both in zone n going into alarm within the Verified Alarm Duration of each other The Bell tamper is considered to be in all zones The Clear Alarms command will clear any existing or potential verified alarms Note however that 1f more
58. e 1 Primary to line 3 Press 4 2 Secondary comm type Request for confirmation to remove Remove all Press if removal required type events Press X if removal not required Press YES or NO comm type type PRIMARY Primary SECONDARY Secondary COMMUNICATIONS TYPE View COMMS TYPE View Select View VIEW Select Primary or secondary COMMS TYPE Use or W to scroll required type 1 Primary to line 3 Press 2 Secondary For Primary PRIMARY Display of Communicator type PARALLEL EVENTS Use A or W to scroll Press communicator comm type For Secondary SECONDARY Display of Communicator type PARALLEL EVENTS Use A or W to scroll Press communicator comm type Returns to menu Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 47 CONFIGURE REMOTE COMMS EVENT GROUPS Configure remote comms event groups Events are the zone point system messages which are sent to a Remote Site Events are collected together to form an Event Group The group 18 assigned a number which has a significance based on the type of communications Parallel The Event Group number represents the parallel port pin which will be activated ADEMCO emulation The Event Group number represents the channel number Serial The Event Group number represents the channel number Priority Events For ADEMCO emulation and Serial the priority of Event Reporting over Management functions
59. e activated legitimately during the entry exit procedure Buffer point A point which generates a prewarning if activated during the entry exit procedure by the user mistakenly deviating from the entry exit route This prewarning is canceled by returning the point to normal and logging on at a keypad Exit Delay Time Specifies the time within which the exit procedure must be completed Entry Delay Time Specifies the time within which the entry procedure must be completed Timed setting Specifies whether the system is to be set following expiry of the exit time An exit point Is not required in systems with timed setting Verifiable Specifies whether Entry Timeout is to be a verifiable alarm see VERIFY ALARM CONFIG MENU System Select System MODIFY SYSTEM E E Route lt Select E E Route ENTRY EXIT ROUTE Add E E ROUTE Add lt Select Add ADD E E ROUTE Specify E E route number Enter route Enter 1 digit number Press number x ADD EE RTE E Specify E E route descriptor Enter Descriptor Select characters see USING THE KEYPAD ADD E E ROUTE E Specify point to be used for entry exit route Add point Select Add point Menu may also contain change and remove CONFIGURE ENTRY EXIT ROUTE Add continued overleaf 20 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F CONFIGURE ENTRY EXIT ROUTE Add continued ADD E E ROUTE E Specify point on E E route Enter Point Enter 3 digit
60. e log in method to be used on the system When a method is specified as required this means that the method is essential for a user to log in For example if the system has required then users must use a PIN or if the system has PIN required and Card required then users must use a Card and also a PIN in order to log in When a card is specified as required but the keypad is not configured to have a card reader then the PIN will be used to log in at that keypad FUNCTION SELECTe Configuration Select Configuration CONFIG MENU System Select System SYSTEM Misc Sys Param Select Misc Sys Param MISC SYS PARA 1 Login Method Select Log in Method LOGIN METHOD Select whether PIN entry is required PIN status Press X to retain displayed status Change YES or NO Press to change displayed status PIN status PIN required PIN not required LOGIN METHOD Select whether Electronic key is required Electronic Key Press X to retain displayed status El key status Press to change displayed status Change YES or NO El key status 1 required not required LOGIN METHOD Select whether Card is required Card Press X to retain displayed status Card status Press to change displayed status Change YES or NO Card status required not required Returns to MISC SYS PARAMS menu if successful Windsor 700 Service Manual V8 4 Iss 0F Guardall Lt
61. ed The point output must be configured to react to some point zone or system condition Usually it will be configured as a monitor point linked to a signalling point input this point input is then wired to a request to exit button CONFIG MENU UI Port Select UI Port UI Add Select Add UI PORT Specify address of UI Enter address x Enter 1 digit number Press UI PORT K Specify descriptor of UI Enter descriptor Select characters see USING THE KEYPAD UI PORT K Specify type of UI Select type Use or to scroll required UI type UI type menu to line 3 Press V UI type menu normal CONFIGURE UI Add continued overleaf 62 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F CONFIGURE UI Add continued UI PORT K Specify zone s to be controlled by UI zone state ZZ Press to change displayed status 2222222222222227 Press X to retain displayed status Change YES or NO Repeats for all zones zone state Controls zone NOT for zone UI PORT K If the UI is disabled when all its zones are set set line 1 the display will be blanked In this state in set zone pressing a key unblanks the display and the user Change YES or NO may log in Press to change displayed status set line 1 Press X to retain displayed status UI Disabled when UI Enabled when UI PORT K If the UI is disabled when all its zones are unset line 1 unset the display will
62. et D1 xxx Repeat for number of points DORMITORY D Specify number of point inputs in set Number of points Enter 3 digit number Press in set D2 xxx CONFIGURE DORMITORY Add continued overleaf 16 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F CONFIGURE DORMITORY Add continued DORMITORY D Enter point for set D2 Xxx DORMITORY D First Delay t1 seconds DORMITORY D Second Delay t2 xx minutes NOTES invalid number Used by Dl retry DORMITORY Remove DORMITORY Enter dormitory number xx DORMITORY View DORMITORY Enter dormitory number xx Specify point input number Enter 3 digit number Press Repeat for number of points Specify first delay time 0 to 60secs Enter 2 digit number 00 to 60 Press Specify second delay time 0 to 60mins Enter 2 digit number 00 to 60 Press Returns to DORMITORY menu The number selected is out of range or the number is a value already selected The point is already in set D1 and may not be in D2 DORMITORY Remove Select Remove Specify set number Enter 2 digit number Press Returns to CONFIG MENU if successful DORMITORY View Select View Specify set number Enter 2 digit number Press CONFIGURE DORMITORY View continued overleaf Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 17 CONFIGURE DORMITORY View continued VIEW DORM D Dis
63. eturns to CONFIG MENU NOTES COPY CONFIG The configuration data in the PROM Pack From pack FAILED is corrupted and invalid Transfer of this checksum error data is therefore prevented CONFIGURE COPY CONFIGURATION continued overleaf 14 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F CONFIGURE COPY CONFIGURATION continued CONFIG MENU Copy Config COPY CONFIG To prom pack INSTALLATION Pack x Vigil x YES to continue COPY CONFIG Pack Vn x x Vigil Vn x x YES to continue COPY CONFIG Copying please wait NOTES Copy has failed Try new pack Inform Technical Support Select Copy Config Select To prom pack If the PROM Pack installation number is not the same as the Control Unit data The installation data is displayed Press to continue Press X to abort If the PROM Pack software version is not the same as the Control Unit The software version numbers are displayed Press to continue Press X to abort Wait for data to be transferred Returns to CONFIG The configuration data transfer has failed due to the PROM Pack Press C to return to menu Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 15 CONFIGURE DORMITORY This facility enables the configuration of the two dormitory areas Dormitories are interrelated points intended to provide false alarm immunity from accidental activations This works by allowing a limited amou
64. figuration System set or examination modification partially set The zones must be unset to continue Press C Configuration Other users are logged on disable or a remote user is logged on Other users This prevents configuration examination logged on Press C Configuration The comms link is in use disable This prevents configuration examination Comms in use Press C Press CLEAR CONFIGURE START END CONFIGURATION continued overleaf 60 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F CONFIGURE START END CONFIGURATION continued CONFIG MENU END Config END CONFIGURATION checking config please wait CONFIG NUMBER XXXXXX y YES key to continue Re initialising System Please WAIT NOTES CONFIGURATION ERROR error line 1 error line 2 CONFIGURATION IS TOO LARGE Press CLEAR to return Limited maximum no of users xx INFORM MASTER Press CLEAR Windsor 700 Service Manual V8 4 Iss 0F CONFIGURATION End Select END Config The configuration is checked for anomalies For small configurations this may be displayed only for a short time If configuration is acceptable Display of updated version number XXXXXX is the site i d and may be changed y is the config version and may not be changed Press V to continue Wait for the system to re initialise with the new configuration The display will clear and then return to FUNCTION SELECT menu if successful
65. hhhhh Use or W to scroll point list Pt III in list Press C to continue pa sb Liga Dg gu Ea Ua Lig Returns to HS SHUNT menu Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 93 DEFINE INOVA MPC CARD IDs The INOVA MPC card IDs enable the Windsor 700 to communicate with an INOVA PrintServer The INOVA PrintServer is supplied with two Master Programming Cards MPCs each of which has an embossed 4 digit number These two numbers are configured on the Windsor 700 using this option CONFIG MENU System lt Select System MODIFY SYSTEM e Remote Comms Select Remote Comms REMOTE COMMS INOVA MPC Select INOVA MPC INOVA MPC Specify 1st or 2nd card id to modify Master card x Enter 1 digit number Press INOVA MPC n Specify MPC card id Enter id 0000 Enter 4 digit number Press v Returns to the REMOTE COMMS menu 94 Guardall Ltd Windsor 700 Service Manual V8 4 155 0 DEFINE INVALID PIN RESPONSE The Invalid PIN Response allows the users to unset a specified zone s regardless of schedule restrictions by entering four consecutive invalid PINs You should further specify which zones can be unset using this method see ZONES ADD CONFIG MENU System Select System SYSTEM Misc Sys Param Select Misc Sys Param MISC SYS PARA 1 More Params Select More Params MISC SYS PARA 2 Ke
66. ibute verifiable NOT verifiable See POINT INPUT Add For double buffer and Safe Shunt Slave Display of controlling point inputs Use A or W to scroll Press to continue Display of concentrator type Press to continue Display of thresholds Press to continue Display of Automatic Shunt delay Press to continue Display of alarm delay type Press to continue If alarm delay Display of alarm delay period t1 Press to continue Display of alarm delay period t2 Press to continue Returns to CONFIG PT I P menu Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F CONFIGURE POINT OUTPUT Point Outputs are the output connections on a concentrator and daughter board if fitted by which external devices i e indicators are driven by the system Point Outputs are assigned an address which incorporates the concentrator address and the address of the point on that concentrator The first two Point Output addresses on a concentrator are used to provide Walk Test indications and therefore the first configurable point address 15 03 Point Outputs may be programmed to react to the state of Point Inputs zones and or the system Monitor The point output follows the normal off normal state of the event Latched The point output latches into an off normal state following the trigger of the event Momentary The point output goes momentarily off normal following the trigger of the event
67. ice Manual V8 4 Iss 0F CONFIGURE SERIAL EQUIPMENT continued SERIAL EQUIPMENT View SERIAL EQUIPMENT View Select View VIEW Select serial port EQUIPMENT Select number Press v Port number x SERIAL PORT N Display of communicator type comm type Display of serial port baud rate protocol Display of line monitor facility baud rate Press V to continue comm type protocol baud rate not used not used 0 bps ChubbCOM PS 006 1200 bps PAD PS 018 2400 bps V 25bis PS 024 4800 bps Hayes 9600 bps Hayes HDX 19200 bps WindsorModem 38400 bps WModem HDX INOVA Direct SERIAL PORT N Display of session time out facility 1 Press V to continue Session Timeout H MM hh mm non facility 1 Monitor Line No Monitor Line Returns to menu Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 55 CONFIGURE RESPONSES Configure sounders strobes delays and duration Some point types such as NA2 and only activate the local sounder if a line fault is detected when the alarm occurs or if a communication failure is detected within the latent period following the alarm Configure the period over which mains fail should be detected before a Mains Fail alarm is generated CONFIG MENU System SYSTEM Responses SOUNDER DELAY XX minutes SOUNDER DURATION XX minutes STROBE DELAY XX minutes STROBE DURATION XX minutes LATENT PERIOD XX minutes
68. id number The number selected is out of range invalid point The number selected is not configured or it is already assigned ENTRY EXIT ROUTE Modify E E ROUTE Modify Select Modify for ENTRY EXIT ROUTE Add ENTRY EXIT ROUTE Remove E E ROUTE Remove Select Remove REMOVE E E ROUTE Specify E E route number Enter route Enter 1 digit number Press number x REMOVE E E ROUTE Display of E E Route descriptor Remove route E for confirmation eeeeeeeeeeeeeeee Press to remove Press YES or NO Press X to abort Returns to E E ROUTE menu ENTRY EXIT ROUTE View E E ROUTE View Select View CONFIGURE ENTRY EXIT ROUTE View continued overleaf 22 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F CONFIGURE ENTRY EXIT ROUTE View continued VIEW E E ROUTE Specify E E route number Enter route Enter 1 digit number Press number x E E E PT III e Display of point input s on route iiiiiiiiiiiiiiii Display of point function point use Use or to scroll point details point use Press to continue point use Entry pt Exit pt Entry route pt Exit route pt Entry Not used Exit Not used VIEW E E ROUTE E Display of entry time period Entry delay xxxx Display of exit time period Exit delay xxxx Press to continue seconds VIEW E E ROUTE E Display of set function on route expiry set fct Press to continue route expiry ve
69. iiiiiiiiiiiiii displayed effect Press YES or NO Press to deisolate warning message Press X to scroll warning message Alarm cond Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 113 RESET NET RESTART This facility restarts the Data Gathering and User Interface Networks RESET AND MUTE e Net restart Select Net restart Returns to the FUNCTION SELECT menu 114 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F RESET SERVICE This facility performs the following 1 Remove all shunts and isolates 2 Clear all latched point inputs and outputs 3 Restart the Data Gathering network and the User Interface network On completion the system is left unset RESET AND MUTE Service Reset Select Service Reset Returns to the FUNCTION SELECT menu NOTES RESET FAILED Check the system status to see what is still SYSTEM STILL in alarm IN ALARM Press CLEAR Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 115 SERVICEMAN COMMISSION REMOTE COMMS Windsor 700 is able to talk to the GuardStation remote controller This allows a central user to monitor and manage many systems Windsor 700 can also be configured to report alarms to the GuardStation Having configured the system and set up GuardStation the remote link must be commissioned This allows the GuardStation to pass essential information to the Windsor 700 which will be required for future conversat
70. individual cards may be identified if required The prefix may contain wildcard digits which match any digit Each card prefix is configured to be associated with specific readers The card access is enabled for a configured period The open period is applicable to all the readers in the system It will be repeated for each day of the week and will be unaffected by holidays Open time The start of the period during which a valid card read will be acted upon Close time The end of the period during which a valid card read will be acted upon When a card is swiped the following sequence of checks occurs If any check fails the operation is aborted The card prefix 18 checked The card expiry date is checked The lobby access period is checked for open period If the above checks are passed then the associated point output is activated This is usually used to activate a door strike which will allow the lobby door to open To configure this point output see CONFIGURE UI CONFIG MENU System lt Select System MODIFY SYSTEM e Lobby access Select Lobby access TIMES LOBBY ACCESS Times Select Times LOBBY TIMES Specify lobby open time start Open time hh mm Enter 2 digit number for hour Press Enter 2 digit number for minute Press CONFIGURE LOBBY ACCESS continued overleaf 26 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F CONFIGURE LOBBY ACCESS continued LOBBY TIMES Close
71. indsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 13 CONFIGURE COPY CONFIGURATION The PROM Pack allows configurations to be transferred between the Windsor 700 and the Windsor 700 Configuration Editor PC software or between Windsor 700s Power should be removed before the PROM Pack is plugged into or removed from the Control Unit board Note that 1f a configuration 1s transferred from one Windsor 700 to another and remote communications is in use all remote sites should be decommissioned on the new Windsor 700 before using the remote communications facility See SERVICEMAN COMMISSION REMOTE COMMS COPY CONFIG From PROM PACK CONFIG MENU Copy Config Select Copy Config COPY CONFIG From prom pack Select From prom pack If the PROM Pack installation number is not the INSTALLATION same as the Control Unit data Pack x The installation data is displayed Vigil x Press V to continue YES to continue Press X to abort If the PROM Pack software version is not the COPY CONFIG same as the Control Unit Pack Vn x x The software version numbers are displayed Vigil Vn x x Press V to continue YES to continue Press X to abort COPY CONFIG Specify whether the user data in the configuration Keep old user on the Control Unit is to be retained or whether table the user data in the PROM Pack is to be imposed Press YES or NO Press V to retain the users Press X to impose PROM Pack user data R
72. iod of time known as the new PIN lockout period This facility is provided to prevent PIN changing being used as a means to discover other PINs CONFIG MENU System SYSTEM Def Time Param DEF TIME PARAMse New PIN lockou DEF TIME PARAMS New PIN change lockout xx days Select System Select Def Time Param Select New PIN lockou Specify the period during which a PIN may not be changed Enter 2 digit number days Press Returns to DEF TIME PARAMS menu Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 101 DEFINE PIN COMMAND FACILITY The PIN Command facility allows the user to quickly set or unset a specified zone by entering the PIN followed by the Clear key They are then prompted for the number of the zone to set unset CONFIG MENU System Select System SYSTEM Misc Sys Param Select Misc Sys Param MISC SYS PARA 1 More Params Select More Params MISC SYS PARA 2 PIN commands lt Select PIN commands PIN COMMANDS Specify if PIN commands are allowed line 2 Press X to retain displayed status Facility Press to change displayed status Change YES or NO line 2 No PIN Command PIN Command Returns to the MISC SYS PARAMS menu 102 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F DEFINE PIN EXPIRY To reduce the likelyhood of PINs being discovered each PIN must be changed every so often This period is know
73. ions Having commissioned remote communications the information passed to the Windsor 700 is stored in the same memory as the configuration The act of decommissioning deletes this information There are several reasons for wanting to do this 1 the GuardStation is being taken out of service and the Windsor 700 must no longer communicate with it ii the network address or telephone number of the GuardStation has changed so the remote communiations must be recommissioned iii the GuardStation has been replaced by another without copying the database from the old to the new iv the configuration has been copied from another Windsor 700 in this case all sites must be decommissioned before any is recommisioned failure to do this will result in the Windsor 700s having the same identity and v remote communications was configured with encryption disabled but encryption is now required the encryption keys form part of the information passed during commisioning Note that decommissioning does not communicate with the GuardStation therefore a similar procedure called deinitialising must be carried out there Note also that encryption for a given site may be enabled or disabled using the Remote Comms option Encryption COMMISSION REMOTE COMMS FUNCTION SELECTe PIN User menu lt Select PIN User menu PIN USER MENU Commission RC Select Commission RC COMMISSION RC Site selected rrrrrrrrrfrrrrrrr Press YES
74. iority Events priority Low priority High priority VIEW type Display of group events Group nnnn Press to continue message message nessage As in CONFIGURE EVENT GROUPS Add and including Hist log events 52 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F CONFIGURE REMOTE COMMS SERIAL EQUIPMENT Configure type of serial equipment and mode of operation Monitor Line facility The health of the telephone line connection is periodically checked Session Time out The maximum time for which an idle connection is retained since the last communication CONFIG MENU System Select System SYSTEM Remote Comms Select Remote Comms REMOTE COMMS Serial Equip lt Select Serial Equip SERIAL EQUIPMENT Modify SERIAL EQUIPMENT Modify Select Modify MODIFY Select serial port EQUIPMENT Enter 1 digit number Press V Port number x The range is 1 to 2 unless a four serial port mezzanine board is present when it is 1 to 6 SERIAL PORT N Select communicator type or none Communicator Use or to scroll required communicator type menu line to line 3 Press type menu line type menu line not used ChubbCOM PAD V 25bis Note For Hayes and V 25bis the device Hayes connected must be Hayes HDX 8 data bits No parity 1 stop bit WindsorModem Wmodem HDX HDX Half Duplex INOVA Direct CONFIGURE S
75. ithin which it is to be performed The test times can be configured in one of two ways Daily The test will run at the configured time on the specified day Periodically The test will run on the specified day at times separated by the configured period with the first test at the specified period after 00 00 midnight For example if the configured period is 07 00 the test will run at 07 00 14 00 and 21 00 CONFIG MENU System Select System SYSTEM Def Time Param Select Def Sys Param DEF TIME PARAMse Timed function Select Timed function TIMED FUNCTION Enter number x Specify number of timed function Enter 1 digit number 1 to 4 Press V TIMED FUNCT T e Detector test Select Detector test AUTO DETECTOR TEST Daily TIMED FUNCT T e Daily Select Daily Specify days and times for test TIMED FUNCT T If no test for the day day Press to change from no test no test Press X to retain no test Change YES or NO day Monday Sunday DEFINE AUTO DETECTOR TEST Add continued overleaf Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 79 DEFINE AUTO DETECTOR TEST Add continued TIMED FUNCT T day at hh mm TIMED FUNCT T day at hh mm Change YES or NO TIMED FUNCT T day at hh mm TIMED FUNCT T stat zone ZZ status Change YES or NO stat 1 in NOT in TIMED FUNCT T Periodically TIMED FUNCT
76. ked Use or W to scroll system states Press to continue Returns to POINT O P menu Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F CONFIGURE REMOTE COMMS COMMUNICATIONS TYPE Alarms may be reported to the central station by three means 1 a parallel communicator such as a Redcare STU or digidialer 1 ChubbCOM emulating Ademco dialler 11 a serial communicator such as ChubbCOM modem or a PAD Primary Secondary The definition depends on the mode Parallel Port Communicators Applies to the Control Unit Thus one communicator is designated the primary communicator and transmits the event messages unless a fault arises Then the events are transmitted by the secondary communicator Serial Port Communicators Applies to the Remote Site Thus one remote site is designated the primary site and one is designated the secondary site Note that this may simply refer to different hardware in the same place or be geographically separate ADEMCO Emulation The ChubbCOM communicator may be used as a dialler performing the same functions as an ADEMCO dialler CONFIG MENU System Select System SYSTEM Remote Comms Select Remote Comms REMOTE COMMS Comms Type Select Comms Type COMMUNICATIONS TYPE Add COMMS TYPE Add Select Add ADD Select Primary or secondary COMMS TYPE Use or W to scroll required type Comms type to line 3 Press Comms
77. lay t1 in secs or mins as above Delay tl xxx Enter 3 digit number Press ADD PT I P III Specify delay t2 units Delay t2 in Use or W to scroll required delay units t2 units menu to line 3 Press t2 units menu t2 units menu Seconds Minutes ADD PT I P III Specify delay t2 in secs or mins as above Delay t2 xxx Enter 3 digit number Press Returns to CONFIG PT I P menu NOTES Add point not in menu The max number of points already configured invalid number Number is out of range or the number has already been allocated not avail retry The number is allocated to a double buffer point or a safe shunt slave POINT INPUT Modify POINT I P Modify lt Select Modify ed ess does n s continue as for POINT INPUT Add CONFIGURE POINT INPUT continued overleaf 36 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F CONFIGURE POINT INPUT continued POINT INPUT Remove POINT I P Remove Select Remove REMOVE PT I P Specify point input number Enter point Enter 3 digit number Press number xxx Returns to CONFIG MENU if successful POINT INPUT View POINT I P View Select View VIEW PT I P Specify point input number Enter point Enter 3 digit number Press number xxx VIEW PT I P III Display of point descriptor iiiiiiiiiiiiiiii Display of point type point type Display of point address address cc pp Press t
78. le alarm Press to change the displayed status Press X to retain the displayed status Returns to MISC SYS PARA 3 menu Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F DEFINE WORK LATE TYPE Define if Late Working is to be fixed increment or a variable increment For the fixed increment the extension time is defined Note This defines whether the Early Opening type is fixed or variable as well CONFIG MENU System SYSTEM Misc Sys Param MISC SYS PARA 1 Work Late Type MISC SYS PARAM Fixed increment work late stat Change YES or NO work late stat Work Late USED Work Late UNUSED MISC SYS PARAM Work Late Delay increment minutes Windsor 700 Service Manual V8 4 Iss 0F Select System Select Misc Sys Param Select Work Late Type Specify whether a fixed or variable increment is to be used for late working Press to change the displayed status Press X to retain the displayed status If fixed increment used Specify increment Enter 3 digit number Press Returns to MISC SYS PARAMS menu Guardall Ltd 111 POINT INPUT ISOLATE DEISOLATE Isolating a detector causes off normal and tamper states to be ignored This is useful when you require a system to set despite point s being in tamper or at fault The point must be configured as isolatable for this procedure and there is a configured limit to the number of isolated or soaked points in a
79. load FUNCTION SELECTe PIN User menu Select PIN User menu PIN USER MENU Remote Config Select Remote Config SUPERVISE CONFIG The download period is ready to start Start download Press C to grant permission and start the within 30 min timeout Press Clear If abort is required perform a Service Reset 122 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F SET FORCE This facility allows setting when points are off normal or a system defect is present by presenting the off normal points to be shunted the shunt limits still apply SET FAILED Force set FORCE SET SHUNT Press YES or NO III 111111111111 off normal FORCE SET ALLOW Press YES or NO defect defect Battery Low NOTES CALL SECURITY Shunt limit exceeded Follows failure of conventional set operation Select Force set If points off normal Press to shunt point If system defect Press V to override The set operation is re tried automatically The point is configured as non shuntable or the total shunt limit is exceeded Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 123 SET LINE FAULT OVERRIDE This facility configures the Line Fault Override status of the system When Line Fault Override is in operation then a user may set the system irrespective of the Line Fault status of the communicator The Line Fault Override status established by the method below is not retai
80. must is selectable If High Priority Events are selected then management function in progress when event information requires transmission is suspended and the events information will be sent Note that if both the primary and secondary communicators are serial then the event group will go on either depending on the status of the receiver CONFIG MENU System Select System SYSTEM Remote Comms Select Remote Comms REMOTE COMMS Event Groups Select Event Group EVENT GROUPS Add EVENT GROUPS Add Select Add ADD GROUP Select primary or secondary 1 Primary Use A or W to scroll required type 2 Secondary to line 2 Press For Parallel ADEMCO emulation ADD PRIMARY Select group number Event Group Enter 2 digit number Press Enter No xx CONFIGURE EVENT GROUPS Add continued overleaf 48 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F CONFIGURE EVENT GROUPS Add continued ADD PRIMARY Event Group Enter No Xxxx group type No 1 priority Priority Events Change YES or NO For Serial Event Reporting Select group number Enter 4 digit number Press For Serial Event Reporting ADEMCO Emulation Select priority Press to change displayed status Press X to retain displayed status group type priority PRIMARY Low SECONDARY High PRIMARY MESSAGEe type menu type menu type menu type menu Group Complete System mes
81. n as the PIN expiry time After a PIN has expired the user is allowed to log on one final time If the warning message is ignored and the PIN not changed the PIN is deleted and the user is not allowed to log on again If this happens the master can allocate a new PIN using the enable user facility CONFIG MENU System Select System SYSTEM Def Time Param Select Def Time Param DEF TIME PARAMse PIN expiry tim PIN expiry tim DEF TIME PARAMS Specify PIN validity period PIN must change Enter 4 digit number Press after xxxx days Returns to DEF TIME PARAMS menu Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 103 DEFINE PREVENT AUTO SET ALARMS The Prevent Auto Set Alarms facility controls whether an automatic set 1s performed 1f this would cause an alarm This is required in order to satisfy the requirements of BS4737 CONFIG MENU System SYSTEM Misc Sys Param MISC SYS PARA 1 More Params MISC SYS PARA 2 BS4737 Mode BS4737 MODE Auto Set may cause alarms Change YES or NO 104 Select System Select Misc Sys Param Select More Params Select BS4737 Mode Specify whether an automatic set is performed if this would cause an alarm Press X to retain displayed status Press V to change displayed status Returns to the MISC SYS PARA 2 menu Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F DEFINE RESET AUTHORITY
82. n unset zones Press to continue Display of zones controlled by UI Use or W to scroll zone list Press to continue CONFIGURE UI View continued overleaf Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 65 66 CONFIGURE UI View continued VIEW UI PORT Card login card status card status Enabled Disabled VIEW UI access access access access line 1 Lobby access No Lobby access Display of swipe card login facility Press to continue Display of zones controlled by UI Press to continue Returns to menu access line 2 access line 3 Door point Open NN secs Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F CONFIGURE ZONE This facility enables the creation or modification of a zone the removal of a zone from the configuration or provides information on the zone s already configured Normal The default zone type Secure A zone which is always set and cannot be unset Special secure This zone type is obsolete and should not be used ATM Bypass A zone with one or more ATMs which may be accessed using the ATM Bypass feature Max number of isolated points This number must be less by at least one than the number of isolatable points in the zone Max number of shunted points This number must be less by at least one than the number of shuntable points in the zone Linked for set Zones which will be set when this one is set
83. ned in the non volatile configuration memory and will therefore be lost if the Control Unit is de powered Also the existing Line Fault Override will be cleared if a configuration is entered If it is required to place the Line Fault Override status in the non volatile configuration memory see DEFINE LINE FAULT OVERRIDE LINE FAULT OVERRIDE Enable FUNCTION SELECTe Set Options Select Set Options SET MENU LF override Select LF override Returns to SET MENU NOTES LF override not in menu Line Fault Override is already configured LINE FAULT OVERRIDE Disable FUNCTION SELECTe Set Options Select Set Options SET MENU Clear LF O R Select Clear LF O R Returns to SET MENU NOTES Clear O R not in menu Line Fault Override is not configured 124 Guardall Ltd Windsor 700 Service Manual V8 4 155 0 STATUS DIAGNOSTIC LOG Display the Diagnostic Log This is intended for diagnostic purposes by Guardall No explanation of this log 1s given in this manual FUNCTION SELECTe View Status Select View Status VIEW STATUS Historic log Select Historic log HISTORIC LOG Diagnostic log Select Diagnostic log Press C to return to menu Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 125 STATUS ISOLATE LIST Display list of isolated points see POINT INPUT ISOLATE DEISOLATE in this document and POINT INPUT S
84. ns do not generate alarms However in order to provide diagnostic information every change of state is entered in the historic log The log entries are Point going normal status 0 Point going off normal status 1 Point going into tamper status 3 There is a configured limit to the number of isolated or soaked points in a zone The soak test may be started at any time in an unset zone A detector cannot be removed from soak if so doing would cause an alarm FUNCTION SELECTe Test Select Test TEST MENU Soak test Select Soak test SOAK Start SOAK TEST Soak point Select Soak point SOAK POINT Specify detector point number required Enter point Enter 3 digit number Press number xxx SOAK PT III Confirm selection 1111111111111111 Press V to continue Press YES or NO Press C to abort Press X to select a different point Returns to FUNCTION SELECT menu if successful NOTES invalid number The number is out of range invalid point The point number is not configured or the point may not be placed in soak test is in soak The selected point is already in soak test limit exceeded The zone isolate limit is exceeded TEST SOAK continued overleaf Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 133 TEST SOAK continued SOAK TEST Remove point REMOVE PT III TIITIITITIILIIIIIIIl Press YES or NO NOTES 134 REMOVE
85. nt of sensor activity in a set system without causing an alarm This activity is allowed for say 8 seconds and no alarm is given provided that the sensors return to normal within those 8 seconds and there is no further activity for say 20 minutes To increase the security each dormitory is divided into 2 groups of detectors and once the 8 seconds or another specified time of tolerance has started in one of the groups no activity is permitted in the other group without an alarm being generated Set D1 The first group of points sharing the dormitory function Set D2 The second group of points sharing the dormitory function First delay The period starting with the activation of a point in the dormitory during which that point may remain off normal without causing an alarm Other points in the same set may also go off normal but points in the other set must remain normal to avoid causing an alarm Second delay period starting after the first delay during which all points in the dormitory must remain normal to avoid causing an alarm CONFIG MENU Dormitory Select Dormitory DORMITORY Add DORMITORY Add Select Add DORMITORY Specify set number Enter dormitory Enter 1 digit number Press number x DORMITORY D Specify number of point inputs in set Number of points Enter 3 digit number Press in set D1 xxx DORMITORY D Specify point input number Enter point for Enter 3 digit number Press s
86. number Press Number xxx ADD E E ROUTE E Specify point input type for entry On Entry is PT e Use or W to scroll required type point menu to line 3 Press point menu point menu Not used Route pt Entry point Buffer pt ADD E E ROUTE E Specify point input type for exit On Exit is PT Use or W to scroll required type point menu to line 3 Press point menu point menu Not used Route pt Exit point Buffer pt ADD E E ROUTE Ee Route complete Select Route complete ADD E E ROUTE E Specify exit time Exit delay time Enter 4 digit number 0000 to 3000 Press XXXX Seconds ADD E E ROUTE E Specify entry time Entry delay time Enter 4 digit number 0000 to 3000 Press 4 XXXX Seconds ADD E E ROUTE E Specify if timed setting is required timed set fct Press to change displayed status route expiry Press X to retain displayed status Change YES or NO timed set fct Timed Set on NOT Timed Set on CONFIGURE ENTRY EXIT ROUTE Add continued overleaf Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 21 CONFIGURE ENTRY EXIT ROUTE Add continued ADD E E ROUTE E Specify if entry timeout in alarm verify Entry timeout is required verify status Press to change displayed status Change YES or NO Press X to retain displayed status status verifiable NOT verifiable Returns to E E ROUTE menu NOTES inval
87. o continue point type See POINT INPUT Add For Control Point VIEW PT I P III Display of Control Point function Control point Press to continue function function see POINT INPUT Add VIEW PT I P III Display of shuntable state shunt state Display of isolatable state isolate state Display of displayable state display state Press to continue shunt state isolate state display state is shuntable is isolatable is displayable NOT shuntable NOT isolatable NOT displayable CONFIGURE POINT INPUT View continued overleaf Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 37 CONFIGURE POINT INPUT View continued VIEW PT I P III exempt state verify state attribute exempt state 1 exemptable NOT exemptable VIEW PT I P III Controlled by III JOIXIJSEZIlllll VIEW PT I P III Wiring type wiring type wiring type See POINT INPUT Add VIEW PT I P Threshold 1 Threshold 2 Threshold 3 VIEW PT I P III Auto shunt delay in seconds nnn VIEW PT I P III Alarm delay delay type delay type 1 see POINT INPUT Add VIEW PT I P III Delay t1 xxx in ti units t1 units seconds minutes VIEW PT I P III Delay t2 xxx in t2 units t2 units seconds minutes 38 verify state 1 Display of exemptable state Display of point attribute Display of verifiable condition Press to continue attr
88. one Press and W to move through the message types while leaving the zone unaltered Entering a zone number and pressing v goes to that zone number without changing the current displayed status zone message 1 status Zone ZZ Alarm Zone ZZ USED Zone ZZ Tamper Zone ZZ UNUSED Zone ZZ SET Zone ZZ UNSET Zone ZZ expiry Zone ZZ PA alarm Zone ZZ 24 hour Zone ZZ night Zone ZZ battery Zone ZZ max isol ates Zone ZZ max shun ts Zone ZZ em unse t Zone ZZ Entry Du ress Zone ZZ has shun t Zone ZZ has isol ate Zone ZZ byps s ZZ Autoset Fail Keypad U Locked UI U USED UI U UNUSED Zone ZZ Verify A larm CONFIGURE EVENT GROUPS Add continued overleaf 50 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F CONFIGURE EVENT GROUPS Add continued If Point messages are required POINT MESSAGES Select point messages Report point xxx Press V to change displayed status Point xxx stat Press X retain displayed status Change YES or NO Entering a point number and pressing V goes to that point without changing the current stat status USED Press A and W to move 8 points at a time UNUSED If Door Messages are required DOOR MESSAGES Select door function messages door function Press V to change displayed status Door x status Press X to retain displayed status Change YES or NO door function 1 status 1 Door InvAcc USED Door xx DurAcc UNUSE
89. onsist of a title followed by a numbered list The composition of a menu will vary depending on the system configuration system status and the user The numbers of the items in a menu will vary Hence in this manual the option numbers are not shown only the menu title and the text of the option to select is illustrated For example FUNCTION SELECT Set Options Select Set Options VARIABLE TEXT A text message on the keypad display may often have a number of alternatives Where this is the case a line title is put in square brackets on the display symbol and the lines that will actually appear where appropriate are itemised below For example There are 3 possible text messages in line 3 of the display below POINT STATUS point status 1 point status 1 normal off normal tamper 4 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F USING THE KEYPAD DISPLAY The keypad has a 4 line 16 character LCD display When the keypad is not being used the display will present the appropriate prompt for the user to log on see USER LOG ON in the User Manual or when the keypad is inside a set zone the display may be blank The keys will then be unusable and if anyone tried to use the keys it would cause an alarm KEYS The keypad has 15 keys that are marked with symbols 0 9 Numeric keys AY Keys used to scroll menus and lists v and Enter key X No key C Clear key INDICATOR LIGHTS The ke
90. or W to scroll required schedule to line 2 Press Select Modify for SCHEDULE Add SCHEDULE Remove Select Schedule Specify schedule Use or V to scroll required schedule to line 2 Press Select Remove Returns to Log On if successful Guardall Ltd 59 CONFIGURE START END CONFIGURATION The behaviour of the Windsor 700 is largely controlled by its configuration The configuration will usually be created using the Windsor 700 Configuration Editor PC software The configuration is then transferred to the Windsor 700 either using a PROM Pack See CONFIGURE COPY CONFIGURATION or a GuardStation See CONFIGURE REMOTE CONFIGURATION The configuration may be altered or in an emergency created at the keypad Before altering the configuration the Windsor 700 must be put into configuration mode using the following procedure Note that while the Windsor 700 is in configuration mode it is unable to monitor alarms and all other keypads are disabled CONFIGURATION Start FUNCTION SELECTe Configuration Select Configuration Command Disables Note that the system is no longer able to Panel monitor alarms if the function is continued Press NO Quit Press V to continue YES Continue Press X to abort If successful the CONFIG MENU is presented Continue according to requirement then perform End as described overleaf NOTES CONFIG FAIL Set zones will prevent the con
91. play first delay and second delay Delay t1 N secs Press V to continue Delay t2 N mins VIEW DORM D Display points in Set 1 Point III in Use or W to scroll through list Press V to continue IGIIIIILIIlllidai VIEW DORM D Display points in Set 2 Point III in Use or W to scroll through list Press to continue IIIIIIIIIIILIIlilill Returns to DORMITORY menu 18 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F CONFIGURE EMERGENCY CONFIGURE This facility is not available with Version 8 4 CONFIG MENU Emerg Reconfig Select Emerg Reconfig OPTION Warning that the emergency configuration NOT AVAILABLE facility is not available Press CLEAR Press C to continue Returns to CONFIG MENU Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 19 CONFIGURE ENTRY EXIT ROUTE This facility is used to configure Entry Exit routes Where there are no external means of unsetting a system it is necessary to establish an Entry route to allow the user to traverse a defined route within the premises without causing an alarm in order to reach a keypad and unset the system Similarly an Exit route may be necessary to allow the user to leave the premises after setting the system The Entry and Exit routes may be the same or different Entry point A point which when tripped will start the entry procedure Exit point A point which completes the exit procedure Route point A point which may b
92. played time for the day Press to change from no test Press X to retain no test If change requested from displayed time Specify days and times for test Press A if no test required Press Enter 2 digit number hour Press Enter 2 digit number min Press V DEF TIME PARAMs Returns to menu AUTO BATTERY TEST Periodically Select Periodically Specify days and period interval for test Press to change the displayed period Press X to retain the displayed period Repeat for all days If change requested Specify days and times for test Enter 2 digit number hour Press V Enter 2 digit number min Press Returns to DEF TIME PARAMs menu Guardall Ltd 77 DEFINE AUTO BELL MUTE This facility enables a user to mute the system bells when logging on CONFIG MENU System Select System SYSTEM Misc Sys Param Select Misc Sys Param MISC SYS PARA 1 Auto Bell Mute Select Auto Bell Mute MISC SYS PARAM Specify requirement for Auto Bell Mute Auto Bell Mute Press to change the displayed status status Press X to retain the displayed status Change YES or NO Returns to MISC SYS PARAMS menu status Enabled Disabld 78 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F DEFINE AUTO DETECTOR TEST Those detectors which have a self test capability can be automatically tested This option specifies time s for the test and the zone s w
93. r Timed function number User number User descriptor usually the name Zone number Zone descriptor Date day in numerals month in letters year in numerals Date day month in numerals Time hours minutes in numerals Time hours minutes seconds in numerals Number displayed Number to be entered Concentrator High Security Pre Warning User Interface Keypad Guardall Ltd 7 MENU TREE ENGINEERING 1 Reset or Mute 2 Unset Options 3 Set Options 4 Test 5 View status 6 Point Control 7 PIN User menu 8 Time functions 9 Configuration 0 Quit Guardall Ltd 1 Reset or Mute 4 Quit 1 Full Unset 6 Quit 1 Full Set 3 Test Set 7 Quit 1 Walk test 2 Bell test 7 Quit 4 Historic Log 8 Quit 4 Group Shunt 5 Quit 1 View users 8 Quit 1 Set clock 4 Holidays 5 Quit 7 Teo o 5T o w o wm 2 wf o o o o alafon 0 ofr ofr NJ lt 3 o o aT RP or ort r d 5 2 gez alze lele g e z 2 2lv olz S 3 31813 218 5 5 21212 DE ES Ei 5 1215 2181 3 aI oe 215 91313 13 019 gt 18 o o 3 zlalsls8 slale o gt 9 aja oja o 8 o z 2 910 olz o olc 210 2 2 3 5 2 518 a os g o 5 c S a a 1312185 91 le 2121515 ER olo 6
94. r 2 digit number 01 to 99 Press XX Seconds Returns to UI NETWORK DEF menu NOTES invalid number The number selected is out of range or the number has already been allocated UI Modify Select Modify PT PN continue as for UI Add UI Remove UI PORT Remove Select Remove UI PORT Specify UI Address Enter address x Enter 1 digit number Press CONFIGURE UI Remove continued overleaf 64 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F CONFIGURE UI Remove continued REMOVE UI K kkkkkkkkkkkkkkkk Press YES or NO UI PORT Enter address x VIEW UI PORT K kkkkkkkkkkkkkkkk key status set unset menu key status keyswitch fitted No keyswitch VIEW UI PORT K set status controllable zones are set set status Enabled when Disabled when VIEW UI PORT K unset status controllable zones are unset unset status Enabled when Disabled when VIEW UI PORT Controllable zone ZZ 2222222222222222 Display of descriptor for confirmation Press to remove Press X to abort Returns to CONFIG MENU if successful UI View Select View Specify UI Address Enter 1 digit number Press Display of UI descriptor Display of keyswitch status Press to continue set unset menu No Set Uns menu Set Unset menu Display of activity in set zones Press to continue Display of activity i
95. rify status Returns to E E ROUTE menu set fct 1 Timed Set NOT Timed Set on verify status verifiable NOT verifiable Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 23 CONFIGURE HOLIDAY This facility enables the programming of specified days as holidays which override the schedule for those days The holidays act as a schedule closed window and as such inhibit the zone s associated with the schedule from being unset FUNCTION SELECTe Time functions Select Time functions TIME FUNCTIONS Holidays Select Holidays HOLIDAY Add HOLIDAYS Add Select Add SELECT FIRST DAY Specify first day of holiday of holiday Enter 2 digit number day Press DD MM YYYY Enter 2 digit number month Press Enter 4 digit number year Press HOLIDAY STARTS Confirmation of first day of holiday on day Press if correct DD mmm YY Press YES or NO day 1 Sunday Monday Tuesday Wednesday Thursday Friday Saturday SELECT LAST DAY Specify last day of holiday of holiday Enter 2 digit number day Press v DD MM YYYY Enter 2 digit number month Press Enter 4 digit number year Press HOLIDAY ENDS Confirmation of last day of holiday on day Press if correct DD mmm YY Press YES or NO CONFIGURE HOLIDAY Add continued overleaf 24 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F CONFIGURE HOLIDAY
96. robe prewarning sounder or strobe prewarning sounder or strobe The Windsor 700 hardware has the following configurable drivers Warn 1 Warn 2 CONFIG MENU System lt MODIFY SYSTEM e Mod O P drives MOD O P DRIVERS Prewarn sounder connect state Change YES or NO connect state connected not connected OPEN CIRCUIT 1 e menu menu menu menu Not connected Prewarning Sounder Strobe prewarning sounder or strobe prewarning sounder or strobe Select System Select Mod O P drives Applies to Mk1A hardware only Specify if pre warning used Press to change displayed status Press X to retain displayed status This menu is present on the Windsor 700 but has no effect Specify use for Open Circuit 1 Warn 1 Note Top line of menu shows current status Use or W to scroll required use to line 2 Press CONFIGURE OUTPUT DRIVERS continued overleaf 30 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F CONFIGURE OUTPUT DRIVERS continued OPEN CIRCUIT 2 Specify use for Open Circuit 2 Warn 2 menu Note Top line of menu shows current status Use or to scroll required use to line 2 Press menu menu menu Not connected Prewarning Sounder Strobe Applies to Mk1A hardware only CLOSED CIRCUIT Specify use for Closed Circuit menu Note Top line of menu shows current status Use or W to sc
97. roll required use to line 2 Press This menu is present on the Windsor 700 but has menu no effect Not connected Prewarning Sounder Strobe menu 1 menu Returns to MODIFY SYSTEM menu Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 31 CONFIGURE POINT INPUT Configure point input Point type The point response depends on the type see Surveyors Guide Shuntable The point may be shunted alarm response inhibited tamper response monitored Isolatable The point may be isolated alarm and tamper responses inhibited Exemptable The point may be exempted if off normal the zone containing it may still be set Subsequently the point will become part of the alarm system from the time it goes normal Displayable The point may be displayed Verifiable The point is in a verified alarm function see CONFIGURE VERIFY ALARM Wiring type Depends on the Concentrator to which the point connects Thresholds The boundaries for determining the pulse width signal on the DGN corresponding with the point condition see Hardware Guide Auto shunt When a point goes into alarm the Auto Shunt timer for that point is started When the timer expires then that point is shunted if it is still in alarm subject to the shunt limit in the zone This facility is used in conjunction with Auto Rearm Note that Auto shunt is not a recommended practice in some countries Delayed Alarm Alarms can be delayed to enhance false alarm immuni
98. rtant for the High Security Concentrator where the state thresholds are close together Calibration is not allowed if the present voltage deviates from the nominal normal voltage by more than 6 the point status is not normal or marginal this prevents faulty equipment being calibrated to appear normal FUNCTION SELECT View status lt Select View status VIEW STATUS Point status Select Point status POINT xxx STATUS Press V to view next point l1111111111111111 Use or to scroll point status Press X if the calibration is NOT correct Calibrate OK Enter a three digit number and press to view any point point status 1 normal nn off normal tamper NOTES Calibration is not possible if the point is POINT STATUS not normal or if the point is marginal Calib error close to the thresholds error status error status Point NOT NORMAL Point MARGINAL Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 127 STATUS PRINT CONFIGURATION This facility prints the configuration data of the Windsor 700 system The printout 1s in a compact format employing abbreviations to describe various functions The abbreviations are in most cases self explanatory The meaning of some of the abbreviations is given opposite FUNCTION SELECTe View status VIEW STATUS Historic log HISTORIC LOG Print config PRINT CONFIG e Start printout P
99. s V to change displayed status If a Normal zone Specify if zone is an ATM control zone Press X to retain displayed status Press V to change displayed status Specify if zone is to be a secure zone Press X to retain displayed status Press V to change displayed status If Keypad Alarm configured Specify if zone is to be Invalid PIN unset Press X to retain displayed status Press V to change displayed status Specify if zone has any linked for set zones Press X to retain displayed status Press V to change displayed status If linked zones specified above Specify which zones are to be linked to this zone for set Press X to retain displayed status Press V to change displayed status CONFIGURE ZONE Add continued overleaf Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 69 CONFIGURE ZONE Add continued ADD ZONE ZZ Specify whether selected commands are to have no line 2 access to this zone cmd restricted Press X to retain displayed status Change YES or NO Press V to change displayed status line 2 Zone is NOT Zone is ADD ZONE ZZ Specify whether zone is to be unset using line 2 dual PIN entry dual PIN access Press X to retain displayed status Change YES or NO Press V to change displayed status line 2 Zone is NOT Zone is ADD ZONE ZZ Specify rearm delay time Rearm delay in Enter 3 digit number 000 to 255 Press Seconds x
100. s X to retain displayed status status Press V to change displayed status Change YES or status Disabld Enabled Returns to the MISC SYS PARA 3 menu Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 85 DEFINE BELL TEST TIMEOUT Configure time out for Bell Test This determines when the Bell Test will terminate if the user fails to manually terminate the test CONFIG MENU System SYSTEM Def Time Param lt DEF TIME PARAMse Bell test t o DEF TIME PARAMS Bell tst timeout after xx mins 86 Select System Select Def Time Param Select Bell test t o Specify timeout for bell test Enter 2 digit number Press Returns to DEF TIME PARAMS menu Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F DEFINE DURESS ALARM Duress is the means by which a user can raise an alarm through the keypad when he logs on Therefore if he is forced to provide entry for unauthorized personnel he can raise an alarm without causing suspicion The duress type may be configured as shown below In addition the user may be required to confirm the duress alarm by pressing V to the configured duress confirmation prompt The meaning of each duress type is described elsewhere and is not given here for security reasons CONFIG MENU System Select System SYSTEM Misc Sys Param Select Misc Sys Param MISC SYS PARA 1 Duress Alarm Select Dures
101. s Alarm DURESS TYPE Specify duress type type menu Select required option Press V type menu type menu type menu Type 1 Type 2 Type 3 Type 4 not used Only displayed if a duress type is used DURESS TYPE Specify whether duress confirmation is line 2 required confirmation Press V to change the displayed status Change YES or NO Press X to retain the displayed status line 2 NO duress Use duress Only displayed if duress confirmation is used DURESS CONF TEXT Specify prompt for duress confirmation Select characters see USING THE KEYPAD Only displayed if a duress type is used line 1 Specify whether zone is to be unset on on zone ZZ confirmed duress 2222222222222222 Press V to change the displayed status Change YES or NO Press X to retain the displayed status line 1 1 NOT unset duress Unset on duress Returns to MISC SYS PARAM menu Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 87 DEFINE GROUP SHUNT A Group Shunt allows a group of points to be shunted or unshunted in a single operation If any of the points in the list fail to shunt unshunt then none of the points in the list will be shunted unshunted Such failures can be caused if the user has no access to the zone in which a point lies or if the operation would cause an alarm CONFIG MENU System SYSTEM Misc Sys Param MISC SYS PARA 1 Shunt Lists POINT LIST
102. sage Zone messages Point messages Door messages SYSTEM MESSAGES System message status Change YES or NO system message ALL Alarm Tamper Any Alarm Any Tamper Night Alarm only 24hr Point only PA Alarms only Battery Low Comms Fail Comms Test Tamper on Bell Tamper on Panel DG Network Fail UI Network Fail Mains Fail Autoset Demand System SET System UNSET Clock Changed Service log Max shunts Max isolates Processor Reset System Error Select message type Use or W to scroll required type to line 2 Press If system messages required Select system messages Press to change displayed status Press X to retain displayed status status USED UNUSED CONFIGURE EVENT GROUPS Add continued overleaf Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 49 CONFIGURE EVENT GROUPS Add continued Late Work Active Work Early Activ e Any Zone SET Service access Any schd expiry Tamper set zone Duress PIN Incident Any INOVA InvAcc Any INOVA DurAcc Any INOVA HeldOp Any INOVA ForcOp Any INOVA LnFaul Any INOVA Tamper INOVA Comms Fail ISB failure Battery failure Pri Comms Fail Sec Comms Fail Test Message Verified Alarm Bat test failed If zone messages are required ZONE MESSAGES Select zone messages zone message Press V to change displayed status and move status to next zone Change YES or NO Press X to retain displayed status and move to next z
103. splayed status Change YES or NO Press V to change displayed status line 2 Automatic Set on NOT Set on ADD ZONE ZZ Specify if zone is to be automatically unset line 2 when a schedule opens line 3 Press X to retain displayed status Change YES or NO Press V to change displayed status line 2 line 3 Automatic Unset at open time NOT automatic unset ADD ZONE ZZ Specify if zone may only be unset once within an line 2 open window line 3 Press X to retain displayed status Change YES or NO Press V to change displayed status line 2 line 3 NOT Restricted Unset Restricted Unset in open window CONFIGURE ZONE Add continued overleaf 68 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F CONFIGURE ZONE Add continued ADD ZONE ZZ line 2 Set Unset Menu Change YES or NO line 2 Show zone on Hide zone on ADD ZONE ZZ line 2 controller Change YES or NO line 2 NOT ATM ADD ZONE ZZ line 2 Change YES or NO line 2 NOT secure zone Secure zone ADD ZONE ZZ line 2 PIN Response Change YES or NO line 2 No Invalid Invalid ADD ZONE ZZ line 2 Change YES or NO line 2 No linked zones Linked zones ADD ZONE ZZ Link to Zone ZZ ZZZZZZZZZZZZZZZZ Press YES or NO Specify if zone will be displayed in the Set Unset menu Press X to retain displayed status Pres
104. state If system state linked ADD PT O P OOO Specify the system state s to control the system state point output function 1 Press to change the displayed status Change YES or NO Press X to retain the displayed status system state link line fault linked mains fail NOT linked Detr test fail Returns to POINT O P menu POINT OUTPUT Modify POINT O P Modify lt Select Modify MOD PT O P Specify point output number Enter point Enter 3 digit number Press number xxx DE continue as for POINT OUTPUT Add CONFIGURE POINT OUTPUT continued overleaf 42 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F CONFIGURE POINT OUTPUT continued POINT OUTPUT Remove POINT O P Remove Select Remove REMOVE PT Specify point output s to removed Press YES or NO Press to remove point Press X to retain point POINT OUTPUT View POINT O P View Select View VIEW PT O P Specify point output number Enter point Enter 3 digit number Press number xxx VIEW PT O P OOO Display of descriptor Display of address Address cc pp Display of normal state normal state Press to continue normal state Normally OFF Normally ON VIEW PT O P OOO Display of point output type type Press to continue type 1 Monitor type Momentary type
105. t in zone NOT in zone ADD PT I P III Thresholds XX yy ZZ Change YES or NO ADD PT I P III Thresholds in XXX YYY ZZZ ADD PT I P III Auto shunt delay in seconds XXX ADD PT I P III Alarm Delay delay menu delay menu delay menu None When Set When Unset Always Specify address of point input Enter 2 digit number conc Press Enter 2 digit number input Press Specify concentrator type Use or W to scroll required wiring type to line 3 Press Specify zone s Press to change displayed status Press X to retain displayed status Repeat for all zones Specify thresholds for tamper and alarm Press to change displayed thresholds Press X to retain displayed thresholds If thresholds change selected Specify thresholds Enter 3 digit number Press Enter 3 digit number Press Enter 3 digit number Press Specify automatic shunt delay Enter 3 digit number 000 to 255 Press 000 facility disabled Specify alarm delay type Use or W to scroll required delay type to line 3 Press CONFIGURE POINT INPUT continued overleaf Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 35 CONFIGURE POINT INPUT continued ADD PT I P III Specify delay t1 units Delay t1 in Use or W to scroll required delay units t1 units menu to line 3 Press t1 units menu t1 units menu Seconds Minutes ADD PT I P III Specify de
106. time hh mm LOBBY ACCESS Cards LOBBY CARDS Add ADD LOBBY CARD Card number xx ADD LOBBY CARD Prefix length xx digits ADD LOBBY CARD Digits 1 NN of card prefix ADD LOBBY CARD Digits 17 NN of card prefix ADD LOBBY CARD Cannot be used at UI N Change YES or NO Specify lobby open time end Enter 2 digit number for hour Press 4 Enter 2 digit number for minute Press 4 Returns to LOBBY ACCESS menu if successful If open time and close time are the same the lobby access will be untimed ie 24 hours a day If the close time is earlier than the open time the access will close the day after the open time CARDS Add Select Cards Select Add Specify card number This may apply to a family of cards sharing the same data prefix Enter 2 digit number 01 to 20 Press v Specify length of card prefix 1 to 19 digits Enter 2 digit number 01 to 19 Press Specify digits Select digit numbers 0 to 9 for prefix Use or V for a wildcard this is displayed as If number of digits is 17 or more Specify digits Select digit numbers 0 to 9 for prefix Use or W for a wildcard this is displayed as Specify keypad s which are to recognize the card Press X to retain displayed status Press to change displayed status Repeat for all UI numbers Returns to LOBBY CARDS menu CONFIGURE LOBBY ACCESS continued overleaf Windsor 700 Service Manual V8
107. ty The operating mode of the delayed alarm depends on the configured value of delay period t2 If delay t2 is zero The point must be constantly off normal for the period t1 in order to cause an alarm If delay t2 is non zero The point going off normal starts period t1 During period t1 alarms are not generated by this point remaining off normal or by this point returning to normal and going off normal again At the end of period t1 the period t2 starts If the point is still off normal or goes off normal during period t2 thenan alarm is caused At the end of t2 the sequence may re start with tl being triggered again CONFIG MENU Point I P Select Point I P POINT INPUT Add POINT I P Add lt Select Add ADD PT I P Specify point number Enter point Enter 3 digit number Press number xxx ADD PT I P III Specify point descriptor Enter descriptor Select characters see USING THE KEYPAD 0 complete CONFIGURE POINT INPUT Add continued overleaf 32 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F CONFIGURE POINT INPUT Add continued ADD PT I P III Specify point type Select type Use or W to scroll required point type point type to line 3 Press YES to accept point type 1 Night Alarm 1 Night Alarm 2 Night Alarm 3 24 Hour PA PA day PA silent PA day silent Battery Monitor Signalling Control point 24 Hour Warning 24 Hour Alarm If Control
108. ty configures whether users are restricted in that they are not able to reset a system after a tamper The reset which is restricted is either a manual or an automatic reset function If the Tamper reset is disabled then the restriction applies CONFIG MENU System lt Select System SYSTEM Misc Sys Param Select Misc sys Param MISC SYS PARA 1 More Params Select More Params MISC SYS PARA 2 More Params Select More Params MISC SYS PARA 3 Tamper reset Select Tamper reset TAMPER RESET Specify tamper reset status Press to change displayed status Change YES or NO Press X to retain displayed status Returns to MISC SYS PARA 3 menu status Disabld Enabled Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 107 DEFINE UI LOCKOUT Define the number of consecutive failed PIN entries that are allowed before the keypad is rendered unusable and the period of time that the keypad will remain unusable CONFIG MENU System SYSTEM Def Time Param DEF TIME PARAMse UI lockout tim SYS TIME PARAMS Max number of failed PINS x SYS TIME PARAMS UI lock out time seconds 108 Select System Select Def Time Param Select UI lockout tim Specify the number of failed PINs Enter 1 digit number Press 4 Specify the lockout time Enter 3 digit number secs Press Returns to DEF TIME PARAMs menu Guardall Ltd Win
109. xx 000 for rearm disabled If Autorearm configured ADD ZONE ZZ Specify if autounshunt required AutoUnshunt Press X to retain displayed status unshunt status Press to change displayed status Change YES or NO Returns to ZONE menu unshunt status 1 Enabled Disabled NOTES zone not in menu Maximum number of zones already configured invalid number The number is out of range or the number has already been assigned For isolated and shunt limits see INTRODUCTION ZONE Modify lt Select Modify P EP continue as for ZONE Add NOTES Change zone not in menu No zones are currently configured CONFIGURE ZONE continued overleaf 70 Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F CONFIGURE ZONE continued ZONE Remove ZONE Remove Select Remove REMOVE ZONE Specify zone number Enter number xx Enter 2 digit number Press 74 Returns to ZONE menu if successful NOTES Remove zone not in menu No zones already configured invalid number The number is out of range or the number has not been assigned ZONE View lt Select View VIEW ZONE xx Specify zone number ZZZZZZZZZZZZZZZZ or scroll to required zone Press 2222222222222222 2222222222222222 VIEW ZONE ZZ Display of zone descriptor 2222222222222222 Display of zone type zone type Display of Entry Exit Route E E route E Press to continue zone type See ZONE Add
110. ypad Alarm Select Keypad Alarm KEYPAD ALARM Specify if an invalid PIN response should be Keypad Alarm recognised status Press X to retain displayed status Change YES or NO Press V to change displayed status status Disabled Enabled Returns to the MISC SYS PARA 2 menu Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 95 DEFINE IP PORTS When the Windsor 700 is to be connected to an IP network the well known ports require specification Ports are used in the TCP to name the ends of logical connections which carry long term conversations The well known port is used by the server process as the contact port The two numbers required for the ACU Windsor 700 and the host ie Guardstation are configurable using this option CONFIG MENU System SYSTEM Remote Comms REMOTE COMMS 2 IP Ports IP PORTS ACU XXXXX IP PORTS Host 96 Select System Select Remote Comms Select IP Ports Specify ACU Windsor 700 Port number Enter 5 digit number Press Specify Host Port number Enter 5 digit number Press Returns to the REMOTE COMMS menu Guardall Ltd Windsor 700 Service Manual V8 4 Iss 0F DEFINE LIMIT TIME ADJUST This facility allows the limit on the use of the Time Adjust command to be changed from the default which is 1 adjustment every 28 days to a limit of 2 adjustments in 24 hours CONFIG MENU System
111. ypad has 8 lights to alert you to the following when they are lit Note that with the exception of the Power light the lights will be held off until you log on POWER Mains supply is healthy BATTERY LOW The battery back up capacity is low SHUNT ON A detector has been shunted manually or automatically INVESTIGATE The system is in a condition where a full set is not possible CALL ENGINEER A serviceman is required to reset or rectify the system LINE FAULT The communication to and from the Central Monitoring Station is faulty TAMPER A detector keypad or other component has been in tamper ALARM A detector or other component has been in alarm TONES The keypad contains a sounder to emit tones There are various tones which may emanate a A beep when a key is pressed b A continuous tone for entry exit procedure An intermittent tone for prewarning d A sequence of tones for schedule expiry TO SELECT FROM A MENU The options in a menu take the form of a numbered list To select an option it must be placed at the top line of the menu Use the cursor keys a and 4 to scroll the menu The ability to scroll is shown by a blinking symbol to the right of the menu title To emphasise which is the top line of the menu the number associated with the option is made to blink When the required option in the top line the selection is completed by pressing the V key Windsor 700 Service Manual V8 4 Iss 0F Guardall Ltd 5