Home

Instruction Manual

image

Contents

1. Channel Function Time and Value DMX HEX 1 PAN coarse 0 100 2 PAN fine__ Low Pos High Pos 2 1 16 Bi 0 255 00 FF 0 100 3 Tilt coarse 0 100 4 Tilt fine Low Pos High Pos 11 16Bi 10 255 00 FF 0 100 5 Color open fast Chaser from color to 00 03 0 2 color 1 Brilliant Blue fast color max 140 BPM 1 8 color 2 Blue fast gt 0 43s 3 3 color 3 Blue Purple fast 4 9 color 4 Magenta fast 6 5 color 5 Pink fast 8 0 color 6 Orange fast 9 6 color 7 Canary fast 11 2 color 8 Italian Blue fast 12 7 color 9 Turquoise fast 14 3 color 10 Jade fast 15 9 color 11 Red fast 17 5 open fast 19 0 open slow Chaser from color to 25 3 color 1 Brilliant Blue slow color max 70 BPM 26 9 color 2 Blue slow 2 0 86 s 28 4 color 3 Blue Purple slow 30 0 color 4 Magenta slow 31 6 color 5 Pink slow 33 1 color 6 Orange slow 34 7 color 7 Canary slow 36 3 color 8 Italian Blue slow 37 8 color 9 Turquoise slow 39 4 color 10 Jade slow 41 0 color 11 Red slow 42 5 open slow 44 1 color rotation slow fast CW min 1 4 turns h 50 75 color rotation fast slow CCW max 2 9 turns sec 76 98 Audio color chaser slow each 4 sound impulse 99 gt new color Audio color chaser fast each sound impulse 100 gt new color 6 Shutter Shutter closed 0 15 0 6 Random Strobe different pattern 1
2. This function allows you to read out the actual temperature of the YPOC COLOR Basic Press Enter to confirm or Mode to cancel Inside tempera tures below 80 C are not critical 80 C and more lead the lamp being switched off at a critical point Please note for a save operation that the outside temperature should not exceed 45 C 3 10 7 Fan Control FANS FANS By using this function you can choose between 4 types of fan speed operations Use the Up Down keys to select desired function and press Enter to confirm or Mode to cancel and return to the menu HIGH The cooling fan works continuously at max speed REG The fan automatically raises its speed in order to control inside temperature of the fixture LOGF The fan keeps the adjusted low speed until the temperature exceeds max inside temperature then the YPOC COLOR Basic automatically switch off the lamp LOHI The fan keeps the adjusted low speed until the temperature exceeds max inside temperature then the YPOC COLOR Basic automatically switch from low to high fan speed GLP German Light Production V1 0 15 ARGU 3 10 8 Adjustments and Calibrations ABUL YPOG SS By this function you can adjust and calibrate the positions of the different wheels and other motors This can be necessary after a service or repair work For this function you have to entry the fixture code This work should be
3. BASIC COLOR Instruction Manual from software version 1 0 instruction version 1 0 GERMAN LIGHT PRODUCTS e mail service glp de Internet http www GLP de eh YPOG s This side is intentionally unlabelled GLP German Light Production v1 0 2 1 sp POG Table of contents Description of Device mum uh isismuus nmegneiinimsnsoejeeedpunsendapbkeenanenannendnndeer 5 EE Aeg ERE 6 Preparation and Installation ssssrrnnnnnnennnnnnnnnnnnnnnnnnvnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnnn 7 2 1 GE EE N N EN RE OE EE 7 ER AN A E EE E 7 2 1 2 Mounting plate iss e Gani Seen a GR ES 8 2 2 Secure the YPOC 250 COLOR ne EE SE EE REED RED EE De EE Ee Ee Gee ee be ENE Ee 8 Bad GENESINGS aid SG AG EG Sa ke ee KG GR 9 2 3 1 Power Dose 9 2 3 2 DMX ME cele EE EE EEEE 9 24 FUSE Aa a ER SE E EG Ge aE DE N EE ee E ER 9 The Menu Field OE EE EE Eaa 10 3 1 Adjust the DMX Address DUO Dee ee ee ee ee ee ee ee 11 3 2 The Test Program EE ee EE ee ee a 11 3 3 The Audio Program RUDI ee ee ee ee ee ee ee ee ee ee ee ee ee 11 34 Lamp On Off EP EERS EE EER ER ES ee Reg Bee ee ds ee de ge ee de ed 12 35 Reset FESE eo ee se De Ee Ee ee Ge eie ie Ge ee Ge EG 12 3 6 Running time of lamp and unit TIME ee ee ee ee ee ee ee ee 12 3 7 Continuous Color Wheel EO iss sd se de Se se ds ee es be Ee Ee Ee GE 12 3 8 Invert Pan Movement RPR rnnnnnrvrnrvrnrvrn ee ee ee ee ee ee ee ee ee ee ee 12 3
4. Position Interval In this way Outside optic weekly soft cloth and glass cleaning fluid Color filter monthly soft cloth and glass cleaning fluid Dimmer Shutter yearly vacuum cleaner airbrush etc Fan and air channel monthly vacuum cleaner airbrush etc Reflector yearly soft cloth and glass cleaning fluid Lampe never Moveable parts yearly suitable fatty oil Attention e Never let optical parts come into contact with oil or fat e Before running the fixture wait until all parts are dried up GLP German Light Production v1 0 21 sp POG 6 3 Cleaning the Optical System 1 Pull out the main plug 2 Wait min 20 minutes after the last operation to cool down the fixture 3 Open the upper shell of the head casing by loosening the 4 Phillips screws Two on the front side and 2 on the back side of the head 4 Do the work as explained in the list above 5 Before you put the YPOC COLOR Basic into operation close the casing otherwise your retina can be hurt Va EE EE O O mm ig italian i Blue Orange GLP German Light Production V1 0 22 ep YPOG s 7 Technical Specification Power supply Power consumption 500 Watt blind current compensated EU model AC 230V 50 Hz Fuse protection T3 15A 250V 5x20 mm fine wire fuse US model AC 115V 60 Hz Fuse protection T6 3A 115V 5x20 mm fine wire fuse Lamp Types 1 MSD HSD CSD 230V 250W socket GY 9 5 Type 2
5. bare fingers 6 Put the lamp sheet back into the unit 7 Close the three screws 8 Adjust the optimum light output with the tree adjustment screws on the backside 9 The running time of the lamp LA can be reseed in the TIME Menu 6 Maintenance and Cleaning the YPOC COLOR Basic It is absolutely essential that the fixture is kept clean and that dust dirt and smoke fluid residues must not built up on or within the fixture Otherwise the fixture s light output will be significantly reduced Regular cleaning will not only ensure the maximum light output but will also allow the fixture to function reliable throughout its life GLP German Light Production v1 0 20 sp YPOG s A soft lint free cloth moistened with any good glass cleaning fluid is recom mended under no circumstances should alcohol or solvents be used The inside optical system should be maintained only by authorized persons Please contact your local dealer 6 1 Safety Regulations e Pull out the main plug e Wait min 20 minutes after the last operation to cool down the fixture e Before you put the YPOC COLOR Basic into operation close the casing otherwise your retina can be hurt 6 2 Circumference and Interval rule of thumb The contamination of the fixture depends on the environment details Therefore no general guidelines can be given From this it follows that the intervals are only suggestions from our practice experience
6. only working when no DMX is connected This function can work e g on small events or as an emergency program Lamp On Off LAMP LAMP Use the Up Down keys to select lamp Gf or lamp OFF Press Enter to confirm or Mode to cancel and return to the main menu The lamp GFF command is only working if the shutter is closed at the same time Use an external controller or the manual drive mode see 3 10 1 on page 13 Reset RESE RESE Press the Enter key to run a reset of all fixture functions RST is shown in the display Running time of lamp and unit TIME TIME By this option can read out three different running times of the fixture PONR Running time of the fixture no destructible LA I Running time of the lamp erasable Push the Up Down keys at one time to delete this running time LA 2 Running time of the lamp no destructible Continuous Color Wheel FEOL FLOL This function allows you to control the color wheel continuously If it is switched off the color wheel is stepping directly from one to another color Invert Pan Movement RPA RPAN GLP German Light Production v1 0 12 eP YPOG COLOR This function allows you to invert the Pan movement Use the Up Down keys to select invert BN or OFF Press Enter to confirm or Mode to cancel and return to the main menu 3
7. 0V T 3 15A EU model or 115V T 6 3A US model Please see the printing on the YPOC COLOR Basic for more details Attention e Disconnect AC outlet before changing a fuse e Use only the original declared fuse type GLP German Light Production V1 0 9 eh YPOG s 3 The Menu Field You find the control board on the side part of the base It allows you LED DepIGy to make all necessary adjustments of the YPOC COLOR Basic With the Mode key you get into the main menu Afterwards you can navi gate through the menu with the Up Down keys Push the Enter key to get in the next menu level or to confirm your settings Make them and set functions ON OFF with the Up Down keys Confirm and save it with the Enter key the display shows OK Push the Mode key to cancel the entry and go back to the main menu Mode key Enter key Down key Up key Level 1 Level 2 Level 3 Remark DOC I Define the DMX start address TEST Test program of all functions RUDI ASLW Self running audio program slow AFST Self running audio program fast MSTR Master for the audio program SVPT Basic position for the audio program SIZE Size for the audio program NORM BIG MIDL SMAL LAMP Switch on of the lamp direct at the YPOC COLOR Basic RESE Reset TIME PONR Running time of the fixtur
8. 6 31 7 11 9 Strobe Pulse effect slow fast min frequency 0 7 Hz 32 47 12 12 9 Strobe effect slow fast max frequency 10 Hz 48 239 13 93 Shutter open 240 255 94 100 Lamp ON ignition 254 255 99 100 7 Dimmer Dimmer closed 0 0 3 0 3 0 1 Dimmer 1 99 movement time 0 3 Sek 4 251 4 FB 2 98 Dimmer open 100 252 255 FC FF 99 100 8 Special No function 0 15 00 0F 0 6 Rotating color chaser 32 63 20 3F 13 24 Color chaser C C 1 64 79 40 4F 25 31 slow fast Color chaser C C 2 80 95 50 5F 32 37 slow fast PAN Tilt chaser slow 96 111 60 6F 38 43 GLP German Light Production V1 0 18 fP YPOG COLOR Channel Function Time and Value DMX HEX PAN Tilt chaser fast 112 127 70 7F 44 50 Lamp OFF 230 249 E6 F9 92 97 only if shutter is closed Reset 250 255 FA FF 98 100 9 Movement No movement 0 Movement Size PAN 1 0 5 1 1 0 1 1 7 1 2 5 2 3 3 2 4 1 2 4 9 2 5 7 3 6 5 3 7 3 3 8 0 3 8 8 4 9 6 4 10 4 4 11 2 4 12 TILT size phase see also PAN 13 25 PAN TILT size phase see also PAN 26 37 PAN TILT inverse size phase see also PAN 38 50 Circle size phase see also PAN 51 62 Circle inverse size phase see also PAN 63 75 lying eight size phase see also PAN 76 87 random movement size see a
9. 9 Invert Tilt Movement FTLTJ ee ee ee ee ee ee ee ee ee ee ee ee ee ee 13 3 10 Special Functions SPEL ee ees ee ee ee ee ee ee ee ee ee ee ee ee ee ee 13 3 10 1 Manual Drive MAN ee ee ee ee ee ee Re ee ee ee ee ee 13 3 10 2 Lamp On automatically LAAI ee ee ee ee ee ee ee ee ee 12 3 10 3 Lamp Off via DMX EEUE re sees ese ee ee EE Se Ge 14 3 10 4 DMX Input MK ee ee ee ee ee ee ee ee ee ee ee ee 14 3 10 5 Display DISP EEE EE Ge ee 15 3 10 6 Fixture Temperature IEMP ee ee ee ee ee ee ee ee ee ee ee 15 3 10 7 Fan Control FRAS EE EE EE N 15 3 10 8 Adjustments and Calibrations RR ee ee ee ee ee 16 3 10 9 Default Settings IFSE eeee ee ee ee Re Re Re Re Re ee ee ee 16 31010 FaadbacklFEER sis eDee DEE eEe BEN Ee BE ee ed Ge GE GE Dk oe EE Ee GE 17 3 10 11 Correction Of faults EFL D Luesesesanenandnapndsndtpddnne 17 3 11 Error and Information Message SESSE rer SE GES rnnr rnrn rrr r ennnen nnen 17 GLP German Light Production V1 0 3 sp POG DMX Channel Selection DMX Protocol rnnnvvvnnnnnnnnnnnnnnnnnvnnnnnnnnnnnnnnnnnnvnnnnnnnr 18 Change the Lamp EE EE N IE E aan 20 5 1 Safety Regulations ee ER RR ER ER DE GE Rd EG De EERS 20 5 2 Realize the Lamp Change EE SERE SE ESE SE RE ee ER Ee Ee Ee EE 20 6 Maintenance and Cleaning the YPOC COLOR Basic rnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 20 6 1 Safety Reoulalens es EE EG RE GE RR EE vste 21 6 2 Circumference and Interval rule of thu
10. 9 Invert Tilt Movement RTLT RILT This function allows you to invert the Tilt movement Use the Up Down keys to select invert Off or GFF Press Enter to confirm or Mode to cancel 3 10 Special Functions SPEC SPEC This menu allows you to enter further special functions of the YPOC COLOR Basic In detail they are 3 10 1 Manual Drive MANU MANU This function allows you to drive all the fixture functions manually Select the desired function with the Up Down keys and confirm with Enter Now choose the desired value with the Up Down keys and confirm again with Enter or cancel and return to the menu with the Mode key Function Value Remark PAN 500 255 Pan Position TILT 555 255 Tilt Position COLO 000 255 Color wheel fixed colors SHUT 000 255 Shutter Strobe function the lamp strikes at DMX 255 if dimmer is open DMX 255 DIMR 000 255 Dimmer SPEC 0500 255 Lamp Off Reset 3 10 2 Lamp On automatically LARU LARU GLP German Light Production V1 0 13 sp POG This function enables to switch On the lamp automatically after switching On the fixture Use the Up Down keys to select OM if you want to switch on the lamp automatically after switching on the fixture or GFF if you don t want this function Press Enter to confirm or Mode to cancel and return to the men
11. MSD 230V 200W socket GY 9 5 Optical system Aluminum reflector Fresnell lens 150mm Color 11 dichroic filter plus white Mechanically adjustable Beam angel 8 22 Shutter Strobe Dimmer Strobe effect variable in speed 1 10 flashes per second Continuously mechanical dimmer 0 100 Controlling Standard DMX 512 3 pole XLR Pin 3 Pin2 Ground Pin 1 The DMX addressing starts at the DMX address 001 Pan Tilt Pan Movement 530 in max 2 65 seconds 16 Bit resolution Tilt Movement 280 in max 1 68 seconds 16 Bit resolution Weights and measures Width of the base 380 mm Length of the base 315 mm 390 mm incl handles height head vertical 510 mm Weight net 18 kg GLP German Light Production v1 0 23 eP 8 Index A Audio Program escorriu 11 B BOV C RT EE N 7 Blind current compensatiON ee se ee 9 Cc Calibrations ee se ee ee ER AA Ge ee ee 16 CircumferenCe ee ee ee ee ee Ee AA Ee ee ee ee 21 Te EE OE 7 Connected load ee ee ee ee 9 D Bles oi N 7 Default Settings ee ee ee ee ee ee 16 Description of Device ie ee RA ee 5 DIN VDE 0711 217 sees ee ee ese see ee ee ee ee naa 7 DISP ER aia T 15 DMX EE iaa aaie 9 DMX AddresS iese ee ee ee ee AR Re ee rnrn ee ee 11 DMX dT EE OR OE andrea 14 DMX Protocol ic Essie EE Ge de Me EE Gee 18 E Error MessageS iii sees see kes
12. N VDE 0711 217 The installation should be done by qualified staff only 2 1 1 Clamps Use two clamps on the backside of the YPOC COLOR Basic to mount the unit on a truss each two opposite threads max M10x20 See also printing on the backside of the case GLP German Light Production V1 0 7 sp POG 2 1 2 Mounting plate For a permanent installation of the YPOC COLOR Basic you can use a optional mounting plate to fix the unit on a wall The plate uses 4x screws M6x20 2 2 Secure the YPOC COLOR Basic Regardless of the rigging of the YPOC COLOR Basic you have to use a stipula ted safety wire Therefore you have to thread to safety wire through to two provided holes on the backside of the fixture and connect it with the truss support Pay attention to a safe and proper fastening 16 00 EE o A A U g 33 00 GLP German Light Production v1 0 8 eh YPOG s 2 3 Connections 2 3 1 Power supply 230 Volt 50 Hz Connected load 500W lt gt 2 2 A blind current compensation or 115V 60 Hz Connected load 500W lt gt 4 4 A blind current compensation Please see printing on the case for the right Power supply 2 3 2 DMX DMX 512 Standard input output See also printing on the case for the right pin assignment Pin 3 Pin 2 Ground Pin 1 The DMX Addressing starts at the DMX Address 001 2 4 Fuse The YPOC COLOR Basic electronic system is protected by a 5x20 mm fuse 23
13. done only by authorized persons Use the Up Down keys to select desired function and press Enter to confirm or Mode to cancel and return to the menu Use now the Up Down keys to set the adjustment values and confirm once more with the Enter key or cancel with the Mode key Function Value Remark COLO 99 99 Color wheel CLRE Adjustments in the internal circuit For authorized FACE Must read ON persons only ARES Adjust Reset gt Service manual 3 10 9 Default Settings DFSE DFSE Press Enter to reset all fixture personalities not the adjusted functions to the default values On the display will appear DK to indicate that the defaults are set GLP German Light Production Function Display Default Settings DMX Address BOG 200 I Pan reverse RPAN on OFF v Tilt reverse RILT on OFF v Automatic lamp on LAAU on OFF v Lamp on via DMX BLOF ON v OFF Display DISP VRLIKA Cooling fan FANS HIGH REGY LOOF LOHI Feedback FEED ON v OFF V1 0 16 eP YPOG 3 10 10 Feedback FEED FEED SIC COLOR The YPOC COLOR Basic is provided with a automatic position correction feedback for the Pan and Tilt movement Use the Up Down keys to select ON if you want to enable the feedback function or GFF if you don t want this function Press Enter to confirm or Mode to cancel and return to the m
14. e no destructible L I Running time of the lamp erasable LAE Running time of the lamp no destructible FCOL Continuously movement of the color wheel N RPAN Reverse Pan direction a RILT Reverse Tilt direction 2 SPEC MANU Manual drive of all device functions z LAAU Automatic lamp start BLOF Switch off lamp via DMX 2 DMX Reed out actual DMX values Y DISP Jo Display On Off REN Twist the display TEMP Reed out internal temperature FANS HIGH Maximum cooling fan velocity REG Automatic cooling fan control LOOF Low cooling fan speed gt lamp off LOHI Low cooling fan speed gt automatic ADJU CODE Use the code for entering the calibration menu for XXXX authorized person only COLO Calibration of the color wheel CLRE Settings in the internal memory superuser only FACT Must read ON Protected by a code ARES Adjust Rest DFSE Call on the default function values FEED Pan Tilt feedback error correction On Off EFLG Correction of faults GLP German Light Production V1 0 10 3 1 3 2 3 3 sp VPOG Adjust the DMX Address JOD 1 Right after turning on the YPOC COLOR Basic you can see the current DMX Address If there is no DMX Signal the display flashes JOG I For the address setting please follow this procedure 1 Switch On the YPOC COLOR Basic and wait until the fixture reset has finished RESE is flashing in the display 2 Press the Mode key in order to access the main men
15. enu 3 10 11 Correction of faults EFL TD EFLG Function available for authorized persons only 3 11 Error and Information Messages HEAT This message appears if you try to switch on the lamp within 5 minutes after having switched off lamp too hot The message will appear on the display if the lamp doesn t ignite within 20 seconds The fixture will store this command and automatically ignite the lamp after 5 minutes LAER After the ignition of the lamp was two times not successful the display will show LAER That means the lamp could be damaged or even missed the fixture is overheating or there could be a failure on the igniter or ballast Switch off the power supply and solve the possible problem OTMP This error message informs you that the fixture was overheating and that the relay switches off the lamp Pleas look for possible reasons fan faulty air in outlets blocked or very dirty lamp broken or very old too high ambient temperature Switch off the power supply and solve the possible problem RSER This message informs you that one of the fixture function wasn t able to do its reset correct magnetic sensor stepping motor driver on the PCB cables etc Repair the defect and start the fixture again GLP German Light Production V1 0 17 eP YPOG 4 DMX Channel Selection DMX Protocol BASIC COLOR
16. lso PAN 88 100 10 Speed Pan Tilt relative movement 0 6 Pan Tilt Pan Tilt slow fast Pan Min 530 200 s 7 100 Use this channel 14 also for the Pan Max 530 2 65 s speed of the movements channel Tilt Min 285 110 s 13 Tilt Max 285 1 8 s Lamp ON Shutter open 254 255 FE FF 99 100 Lamp OFF Channel 8 min 3 sec only if 230 249 E6 F9 92 97 shutter is closed channel 6 0 15 Set the function FCQL OM if you want to control the color wheel continuously GLP German Light Production V1 0 19 sp VPOG 5 Change the Lamp For a frictionless operation pleas read this chapter carefully and follow all instructions 5 1 Safety Regulations e Pull out the main plug e Wait min 20 minutes after the last operation to cool down the fixture e Don t touch the bulb of the lamp with bare fingers this can cause damages e Before you put the YPOC COLOR Basic into operation close the casing otherwise your retina can be hurt 5 2 Realize the Lamp Change 1 Pull out the main plug 2 Open the three screws on the backside of the unit 3 Pull out the lamp sheet together with the lamp holder securely 4 Remove the old or broken lamp out of the socket Attention The glass bulb of the lamp can splinter For that reason remove the lamp with safety gloves or some cloth 5 Put in the new lamp securely into the socket Attention Use only the original lamp type and do not touch the lamp with
17. mb eerennnrrnnnnnrrrrrnnnnnnnrrrrnnnnnnnnnn 21 6 3 Cleaning the Optical SY SUSI EER REEDE KEER SN KERR GE RR SE SG ERGE EWER EER EWE EEDEN E EDE 22 Technical SPS Cian aca ss EE REAGEER RE ER Ek Ri nele RA AN Re ees EE EE RE id 23 Vie AA RE EE rene E oe ee eee oe 24 GLP German Light Production v1 0 4 eh YPOG s 1 Description of Device Moving Head Arm Base Carrying handles Up button Down button Enter button Mode button LED Display 10 Software Update connector OMAN Oo a 11 Microphone Intensity 12 DMX Input 13 DMX Output 14 Power On Off 15 Fuse F3 15A 16 Fan air inlet GLP German Light Production V1 0 5 YPOG S 1 1 Safety Instructions The YPOC COLOR Basic is a High Tech Product To guaran tee a smooth operation it is necessary to keep following rules The manufacturer of this device will not take responsibility of damages through disregard of the information in this manual Warranty adjustments will be canceled 1 Make sure before putting into operation that the fan and the air inlets are clean and not blocked by anything 2 Attention Don t touch the device during the operation This can cause injuries or damages 3 Unplug the YPOC COLOR Basic from the AC outlet before any service 4 Itis necessary to wait at least 30 minutes after disconnecting the AC before you o
18. pen the YPOC COLOR Basic Please do not touch the bulb of the lamp if you are not absolutely sure it is cold DANGER OF BURNING 5 Never look directly into the beam of the lamp You risk injury of your retina and blindness 6 Pay attention of the maximum lamp operation time You have to change it if the lamp shows any deformations or damages The same is with all glass components color filters lenses and mirrors 7 To allow a secure operation follow also the Installation guide described in chapter 2 Operating the YPOC COLOR Basic without suited safety aids like Safety cables or clamps hooks can increase the risk of an accident 8 The installation should be done by qualified staff only You need to pay attention to the common rules of technology that are not explicit mentioned in this manual 9 Use only original spare parts Any structural modification will cancel all warranty adjustments GLP German Light Production V1 0 6 P YPOG s As 2 Preparation and Installation 2 1 Mounting The YPOC COLOR Basic is fully operational whether it hangs or is mounted to the wall It can also be operated while standing on the floor Keep a safety distance of 0 5 m towards any easy inflammable materials decoration etc Install a safety wire that can hold at least 10 times the weight of the fixture Never use the carrying handles for secondary attachment Pay attention to the regulations of BGV C1 former VBG 70 and DI
19. se ee ee Se Me ee Ge ge 17 F SE RE OE N 15 dT ER ER EE NA 9 I Injury of the retina n 6 Invert Pan TiE iese ee ee ee se RA Ge Ee Re Re ee 12 L Lamp Change se RASSE EE RE EER N Ee See N 20 GLP German Light Production V1 0 I COLOR Lamp ON ese SE AR GER GE EE REG RE Se 19 M Maintenance ee ee ee Re Re Ee ee ee ee 20 Manual Drive ees ee se ee ee ee RR Re Re Ee ee ee ee ee 13 MeasureS ses RE ie ee Ge ee 23 Te EE EE 10 MOUNUING EE EE OE EE OE 7 Mounting plate ees ee ee ee AR ee ee ee ee 8 P Pan Movement ee ee ee ee ee ee ee ee ee 23 Pow r SuUpplY iese see Ee Ee ee sk ee de ie 9 R Reset RE EE side a 12 S Safety Instructions ee es ee ee ee ee 6 Safety WIE s d es Eg Ge GE de ae ge De ed de 8 ete AR N EE 8 Software version ie see ee ee ee ee ee Ge ee ee ee es 1 Special FunctiONS ee ese ee ee Re Re ee ee 13 T Technical Specification ese se ee ee 23 Temperature iese esse se se Re Re ee ee ee ee ee ee 15 Test Program EE ES ERENS GEK ERGE EE Ee 11 Tilt Movement ee ee ee ee 23 V VBG 70 prie EE helet enine 7 W Weight se ee se ee ek Re Ge AA Ge ee 23 24 sp YPOG s GLP German Light Production v1 0 25
20. u Browse through the menu by pressing the Up Down keys until the display shows JOD I Confirm by pressing the Enter key the decimal point is flashing 3 Use the Up Down keys to select the desired address Confirm the setting by pressing the Enter key the display shows Gk or press the Mode key to cancel The DMX Address is stored also while switching off the YPOC COLOR Basic The Test Program TEST TEST The Test Program allows you to run a complete self test procedure of all functions Press Enter to confirm or Mode to cancel The Audio Program RUDI The Audio menu allows you to run a stand alone audio program This chaser can run either fast or slow AFST Every sound impulse on step of the chaser ASLH Every second sound impulse one step of the chaser Additional you can choose a basic position for this audio chaser Use therefore either the internal manual mode or an external controller to set the desired Pan Tilt position Confirm this setting in the SPLT menu by pressing the Enter key You can also set the size of the audio chaser in the SIZE menu You have the choice between NORM no basic position has to bee chosen BIG MIDL and SMAL If you want to run the systems simultaneously one of the YPOCs must be GLP German Light Production v1 0 11 3 4 3 5 3 6 3 7 3 8 sp VPOG switched as the master All others must be Slave Master OFF Notice The Audio function is
21. u If you have chosen OFF you have the possibility to start the lamp either via DMX or direct at the YPOC COLOR Basic in the Lamp menu 3 10 3 Lamp Off via DMX LOF BLOF This function enables to switch off the lamp via DMX or not Use the Up Down keys to select Gf if you want to switch off the lamp via DMX or GFF if you don t want this function Press Enter to confirm or Mode to cancel and return to the menu 3 10 4 DMX Input BMX 1 BMX Readout DMX values of each channel received by the fixture Use the Up Down keys to select desired channel and press Enter to read its value Function Value Remark PAN D 255 Pan Position TILT D 255 Tilt Position COLO D 255 Color wheel fixed colors SHUT 0 255 Shutter Strobe function SPEC O 255 Lamp OFF Reset MONE D 255 Movement SPED D 255 Speed Pan Tilt GLP German Light Production V1 0 14 sp VPOG 3 10 5 Display DISP JISP Use this function to choose between different display indications Use the Up Down keys to select desired function and press Enter to confirm or Mode to cancel and return to the menu J ON Display On Off If you ve chosen OFF the display will go out within 15 seconds after the last input The next key touch will reactivate the display REV Turn around the display 3 10 6 Fixture Temperature TEMP TEMP

Download Pdf Manuals