Home
Pronto® M51™ Base with SureStep®
Contents
1. Ensure seat is secured to wheelchair frame Ensure seat release latch is functional Replace if necessary Ensure wheel mounting nuts are secure on drive wheels D OO DU DL OU Ensure no excessive side movement or binding occurs when drive wheels are lifted and spun when disengaged freewheeling D Inspect caster assembly has proper tension when caster is spun Caster should come to a gradual stop Loosen tighten caster locknut if wheel wobbles noticeably or binds to a stop Ensure all caster wheel fork headtube fasteners are secure Inspect tires for flat spots and wear Cov Ensure casters are free of debris Pronto M51 Base with SureStep 22 Part No 1148076 SECTION 4 SAFETY INSPECTION TROUBLESHOOTING Inspect Adjust Weekly Q Q Q Seat is secured to wheelchair frame Inspect tires for flat spots and wear Ensure casters are free of debris Inspect Adjust Monthly d d D Cov Ensure wheel mounting nuts are secure on drive wheels Ensure no excessive side movement or binding occurs when drive wheels are lifted and spun when disengaged freewheeling Inspect caster assembly has proper tension when caster is spun Caster should come to a gradual stop Loosen tighten caster locknut if wheel wobbles noticeably or binds to a stop Ensure all caster wheel fork headtube fasteners are secure Inspect for any loose hardware on the wheelchair Ensure casters are free of debris I
2. 3 Install the vehicle anchored upper torso belt onto the pin on the male end of the pelvic belt DETAIL A Back Angle Bracket Belt Mounting Bracket Used to secure the vehicle anchored m upper torso belt Large End of Slot Small End of Slot FIGURE 10 2 Wheelchair Anchored Belts Pronto M51 Base with SureStep 66 Part No 1148076 SECTION 10 TRANSPORT READY PACKAGE Vehicle Anchored Belts NOTE For this procedure refer to FIGURE 10 3 This wheelchair has an overall rating of A with regard to accommodating the use and fit of vehicle anchored belts This rating is scored as follows DESCRIPTION Excellent Good Fair Poor The test for Lateral Stability Displacement for Point P is shown in FIGURE 10 3 The average test result for point P is 0 33 inches 8 4 mm NOTE Rear view of the wheelchair and human surrogate secured on test platform and tilted to 45 FIGURE 10 3 Vehicle Anchored Belts Seating System WARNING This wheelchair has been tested for seating in a motor vehicle with the factory installed seating system ONLY Ensure that the factory installed seating system is secured to the wheelchair frame before operation Refer to the seating system owner s manual Part No 1148076 67 Pronto M51 Base with SureStep SECTION 10 TRANSPORT READY PACKAGE Positioning Belts WARNING The angle of the
3. Battery Battery bus insultar abe Catig Terminal Nut Baite Battery DO NOT atter aller CM Cable 75AMP REMOVE o u Mounting FS HVBF Fuse Screw REAR BATTERY BAIT AWARNING DO NOT operate wheelchair on an incline while in an elevated position Otherwise the wheelchair may tip over and injury or damage may occur 1130210 Rev A 01 05 Part No 1148076 LABEL LOCATION Wheelchairs With TRRO NOTE Also on opposite side TIE DOWN THIS WHEELCHAIR COMPLIES ANSI RESNA WC 19 POINT A WARNING 1083199 Refer to attached TRANSPORT READY OPTION Instruction Card and wheelchair Owner s Manual before use PIN 1082692 REV B 08 05 NOTE Also on opposite side TIE DOWN POINT 1083199 NOTE Also on opposite side TIE DOWN POINT 1083199 4 MISE EN GARDE WARNING SURELOIC Cette ceinture sous abdominale de retenue de l occupant est conforme la norme ANSVRESNA This Occupant restraint pelvic belt conforms with PELVIC BELT TYPE 1 WC 19 ANSURESNA WC 19 Pour obtenir les instructions d utilisation consulter le guide d utilisateur ou s il y a lieu la plaquette For operating instructions refer to owners manual or FE200974 105INV d information murale dans le v hicule Cette ceinture sous abdominale doit tre utilis e avec un equipped wall mounted vehicle placard This pelvic belt is XXX fauteuil roulant positionn vers l AV
4. Do not return products to our factory without our prior consent LIMITATIONS AND EXCLUSIONS THE FOREGOING WARRANTY SHALL NOT APPLY TO SERIAL NUMBERED PRODUCTS IF THE SERIAL NUMBER HAS BEEN REMOVED OR DEFACED PRODUCTS SUBJECT TO NEGLIGENCE ACCIDENT IMPROPER OPERATION MAINTENANCE OR STORAGE COMMERCIAL OR INSTITUTIONAL USE PRODUCTS MODIFIED WITHOUT INVACARE S EXPRESS WRITTEN CONSENT INCLUDING BUT NOT LIMITED TO MODIFICATION THROUGH THE USE OF UNAUTHORIZED PARTS OR ATTACHMENTS PRODUCTS DAMAGED BY REASON OF REPAIRS MADE TO ANY COMPONENT WITHOUT THE SPECIFIC CONSENT OF INVACARE OR TOA PRODUCT DAMAGED BY CIRCUMSTANCES BEYOND INVACARE S CONTROL AND SUCH EVALUATION WILL BE SOLELY DETERMINED BY INVACARE THE WARRANTY SHALL NOT APPLY TO PROBLEMS ARISING FROM NORMAL WEAR AND TEAR OR FAILURE TO ADHERE TO THE PRODUCT INSTRUCTIONS A CHANGE IN OPERATING NOISE PARTICULARLY RELATIVE TO MOTORS AND GEARBOXES DOES NOT CONSTITUTE A FAILURE OR DEFECT AND WILL NOT BE REPAIRED ALL DEVICES WILL EXHIBIT CHANGES IN OPERATING NOISE DUE TO AGING THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IN LIEU OF ANY OTHER WARRANTIES WHATSOEVER WHETHER EXPRESS OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND THE SOLE REMEDY FOR VIOLATIONS OF ANY WARRANTY WHATSOEVER SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT PURSUANT TO THE TERMS CONTAINED HEREIN THE APPLICATION OF ANY IMPLIED WARRANTY WHATSO
5. It is not designed for use as a safety device withstanding high stress loads such as auto or aircraft safety belts If signs of wear appear belt MUST be replaced immediately Before performing any maintenance adjustment or service verify that On Off switch on the joystick is in the Off position Avoid storing or using the wheelchair near open flame or combustible products Serious injury or damage to property may result ALWAYS keep hands and fingers clear of moving parts to avoid injury NEVER leave an unoccupied wheelchair on an incline DO NOT attempt to lift the wheelchair by any removable detachable parts Lifting by means of any removable detachable parts of the wheelchair may result in injury to the user or damage to the wheelchair Make sure the detent balls of the quick release pin are fully released beyond the outer edge of the tube before operating the wheelchair Otherwise injury and or damage may result Keep detent balls clean Accessories Extreme care should be exercised when using oxygen in close proximity to electric circuits and other combustible materials Contact your oxygen supplier for instruction in the use of oxygen Invacare products are specifically designed and manufactured for use in conjunction with Invacare accessories Accessories designed by other manufacturers have not been tested by Invacare and are not recommended for use with Invacare products Part No 1148076 lI Pronto M51 Base with Sure
6. It is possible to unintentionally bring high levels of EM energy very close to the powered wheelchair s control system while using these devices This can affect powered wheelchair movement and braking Therefore the warnings listed below are recommended to prevent possible interference with the control system of the powered wheelchair Electromagnetic interference EMI from sources such as radio and TV stations amateur radio HAM transmitters two way radios and cellular phones can affect powered wheelchairs and motorized scooters FOLLOWING THE WARNINGS LISTED BELOW SHOULD REDUCE THE CHANCE OF UNINTENDED BRAKE RELEASE OR POWERED WHEELCHAIR MOVEMENT WHICH COULD RESULT IN SERIOUS INJURY 1 Do not operate hand held transceivers transmitters receivers such as citizens band CB radios or turn ON personal communication devices such as cellular phones while the powered wheelchair is turned ON 2 Be aware of nearby transmitters such as radio or TV stations and try to avoid coming close to them 3 If unintended movement or brake release occurs turn the powered wheelchair OFF as soon as it is safe 4 Be aware that adding accessories or components or modifying the powered wheelchair may make it more susceptible to EMI NOTE There is no easy way to evaluate their effect on the overall immunity of the powered wheelchair and 5 Report all incidents of unintended movement or brake release to the powered wheelchair manufacturer a
7. charger and an independent battery charger plugged into the joystick charger port at the same time Doing so will reduce the life of the batteries CAUTION Only use a charger approved by Invacare when charging through the joystick on this wheelchair model DO NOT use an independent charger with an output rating of over 8A Amps Otherwise damage may occur NOTE For this procedure refer to FIGURE 9 7 NOTE The charger port located on the front of the joystick requires the use of an independent charger The independent charger is NOT supplied with the wheelchair 1 Attach the battery charger connector to the charger port on the front of the joystick Plug the charger s AC power cord or extension into the grounded 110 volt wall outlet When charging is complete turn charger Off gt m Disconnect output cable from joystick charger port SPJ Joysticks MPJ Joystick Charger Programming Port On Front of Joystick Charger Programming Port FIGURE 9 7 Charging Using An Independent Charger Plugged Into The Joystick Part No 1148076 61 Pronto M51 Base with 5 SECTION 10 TRANSPORT READY PACKAGE SECTION 10 TRANSPORT READY PACKAGE NOTE The information in this section is for wheelchairs ordered with the transport ready package ONLY WARNING Contact Invacare Corporation 800 333 6900 with any que
8. Control The speed control knob is located on the side of the joystick housing 1 Rotate the knob clockwise forward to increase the speed of the wheelchair to the programmed max speed 2 Rotate the knob counterclockwise backward to decrease the speed of the wheelchair to the programmed max speed Joystick The joystick has proportional drive control meaning that the further the joystick is pushed from the upright neutral position the faster the wheelchair or seat moves Your top speed however is limited by the programmed settings To slow the wheelchair to a stop simply release the joystick The wheelchair has automatic speed and direction compensation to minimize corrections Charger Programming Input The charger programming input is located at the front of the joystick housing This provides easy access for charging the wheelchair batteries This port also serves as the Remote Programmer Communication connection Driving is prevented while the system is charging LCD Display Screens The LCD Display is located in front of the joystick and provides information on the status of the wheelchair through a backlit display The LCD display is readable in both bright sunlight and complete darkness Pronto M51 Base with SureStep 34 Part No 1148076 SECTION 5 WHEELCHAIR OPERATION Splash Screen NOTE For this procedure refer to FIGURE 5 5 This screen is displayed at startup of the joystick for about 2 seconds
9. Invacare Dealer SOLUTIONS Engage motor lock levers Refer to Disengaging Engaging Motor Lock Levers on page 48 CHARGER PLUGGED IN displays Battery charger connected Error code E28 Unplug battery charger from the wheelchair Refer to Charging Batteries on page 62 sPM Battery Fault displays and the wheelchair does not drive Batteries need to be charged Error code El4 Charge batteries Refer to Charging Batteries on page 62 If batteries fail to charge properly check battery charger or replace batteries Refer to Replacing Batteries on page 55 JOYSTICK TIMEOUT displays and the wheelchair does not drive Joystick or input device is disconnected Error code 32 Turn off power reconnect the joystick of input device and turn power on JS REV TOO LARGE Q JS FWD TOO LARGE Q JS LFT TOO LARGE or JS RGT TOO LARGE displays and the wheelchair does not The joystick or input device is sending a value outside of the reverse forward left or right limits Error codes E01 E02 E03 or E04 Replace joystick or input device drive Pronto M51 Base with SureStep 26 Part No 1148076 SYMPTOM NEUTRAL TESTING displays SECTION 4 SAFETY INSPECTION TROUBLESHOOTING PROBABLE CAUSE The joystick neutral test has failed Error code E18 SOLUTIONS Release the joystick and try to get the joystick back into the center most position BAD JOYSTIC
10. NOT shift your weight in the opposite direction of the turn Shifting your weight in the opposite direction of the turn may cause the inside drive wheel to lose traction and the wheelchair to tip over DO NOT shift your weight or sitting position toward the direction you are reaching as the wheelchair may tip over DO NOT engage or disengage the motor release levers until the power is in the Off position DO NOT operate on roads streets or highways Pronto M51 Base with SureStep 10 Part No 1148076 SECTION GENERAL GUIDELINES DO NOT climb go up or down ramps or traverse slopes greater than 9 DO NOT attempt to move up or down an incline with a water ice or oil film DO NOT attempt to drive over curbs or obstacles Doing so may cause your wheelchair to turn over and cause bodily harm or damage to the chair DO NOT leave the power button in the On position when entering or exiting your wheelchair DO NOT stand on the frame of the wheelchair DO NOT stand on the flip up footboard otherwise damage may occur When getting in or out of the wheelchair make sure that the flip up footboard is in the upward position DO NOT stand on the front riggings otherwise damage may occur When getting in or out of the wheelchair make sure that the footplates on the front riggings are in the upward position or moved out of the way ALWAYS wear your seat positioning strap The seat positioning strap is a positioning belt only
11. SureStep 16 Part No 1148076 SECTION 3 SAFETY HANDLING OF WHEELCHAIRS Coping With Everyday Obstacles WARNING DO NOT attempt to reach objects if you have to move forward in the seat or pick them up from the floor by reaching down between your knees Proper positioning is essential for your safety When reaching leaning bending or bending forward it is important to use the casters as a tool to maintain stability and balance Many activities require the wheelchair user to reach bend and transfer in and out of the wheelchair These movements will cause a change to the normal balance cen ter of gravity and weight distribution of the wheelchair To determine and establish your particular safety limits practice bending reaching and transferring activities in several combinations in the presence of a qualified healthcare professional before attempting active use of the wheelchair NOTE For this information refer to FIGURE 3 1 Coping with the irritation of everyday obstacles can be alleviated somewhat by learning how to manage your wheelchair Keep in mind your center of gravity to maintain stability and balance While the walking beam allows to traverse up to a 2 inch bump or threshold stopping after the wheels cross the bump poses a problem The chair cannot reverse over the bump at this point Continue forward and then turn around While the wheelchair is designed for use primarily in and around the home the
12. TYPICAL PRODUCT PARAMETERS FORMULA CG ASBA VAN SEAT SEAT WIDTH RANGE 16 to 20 inches SEAT DEPTH 16 to 20 inches BACK HEIGHT 16 to 20 inches BACK ANGLE RANGE 85 to 105 in 5 increments UPHOLSTERY Black Nylon Back with Seat Pan Gray Vinyl SEAT TO FLOOR 17 to 19 inches 18 to 20 inches 19 to 21 inches Solid Wood Base without Cushion OVERALL WIDTH 24 inches Without Joystick OVERALL HEIGHT 41 inches OVERALL LENGTH 34 inches With Footboard Folded 39 2 inches With Footboard Extended DRIVE WHEELS TIRES 10 x 3 inch Flat Free inserts CASTER 6 x 2 inch Front Rear w Precision Sealed Bearings FOOTRESTS Flip Up Depth and Height Adjustable Footboard LEGRESTS Swingaway Front Rigging Elevating Legrest WEIGHT W O BATTERIES 145 to 170 lbs W BATTERIES U1 192 to 217 lbs SHIPPING BASE W O BATTERIES 107 Ibs BASE WITH BATTERIES 154 Ibs ADJUSTABLE ASBA 20 X 20 X 20 48 lbs ARMRESTS Adjustable Width Angle Heights and Depth BATTERIES WEIGHT LIMITATION 300 Ibs PERFORMANCE SPEED 0 to 4 3 m p h TURNING RADIUS 19 inches FRANGE VARIABLE up to 12 miles Includes seating systems and accessories Values for range are calculated for maximum chair weight rating using largest batteries applicable U1 per test procedures described in ANSI RESNA WC VOL2 1998 Section 4 and meet federal reimbursement requirements for this p
13. be minimized The sources of radiated EMI can be broadly classified into three types 1 Hand held Portable transceivers transmitters receivers with the antenna mounted directly on the transmitting unit Examples include citizens band CB radios walkie talkie security fire and police transceivers cellular telephones and other personal communication devices NOTE Some cellular telephones and similar devices transmit signals while they are ON even when not being used 2 Medium range mobile transceivers such as those used in police cars fire trucks ambulances and taxis These usually have the antenna mounted on the outside of the vehicle and 3 Long range transmitters and transceivers such as commercial broadcast transmitters radio and TV broadcast antenna towers and amateur HAM radios NOTE Other types of hand held devices such as cordless phones laptop computers AMIFM radios TV sets CD players cassette players and small appliances such as elec tric shavers and hair dryers so far as we know are not likely to cause EMI problems to your powered wheelchair Pronto M51 Base with SureStep 14 Part 1148076 SECTION 2 EMI INFORMATION WARNING Powered Wheelchair Electromagnetic Interference EMI Because EM energy rapidly becomes more intense as one moves closer to the transmitting antenna source the EM fields from hand held radio wave sources transceivers are of special concern
14. brackets are engaged with seat clevis pins Rear Pivot Brackets Seat Clevis Pins Latch Bar is located under the front of the seat FIGURE 6 2 Removing Installing the Seat Assembly Part 1148076 43 Pronto M51 Base with SureStep SECTION 7 FOOTBOARD ASSEMBLY SECTION 7 FOOTBOARD ASSEMBLY WARNING After any adjustments repair or service and before use make sure that all attaching hardware is tightened securely otherwise injury or damage may result Before performing any maintenance adjustment or service verify that On Off switch on the joystick is in the Off position DO NOT stand on the flip up footboard When getting in or out of the wheelchair make sure that the flip up footboard is in the upward position Limited Clearance Between Footboard and Caster The user s feet MUST remain on the footboard while operating the chair If the user s feet are allowed to rest off the side of the footboard they may come in contact with the caster possibly result ing in injury Removing Installing the Footboard Assembly WARNING Pinch point may occur when rotating the footboard assembly NOTE For this procedure refer to FIGURE 7 1 on page 45 Removing 1 Remove the quick release pin that secures the footboard assembly to the wheelchair frame by depressing the button while sliding the pin out 2 Remove the footboard assembly from the wheelchair frame Pronto M51 Base wi
15. controller BLACK connector 6 Disconnect the rear battery from the front battery RED and BLACK connectors 7 Lift rear and front battery out of the battery tray using the battery handles Installing 1 Verify the joystick On Off switch is in the Off position and disconnect joystick cable Refer to Disconnecting Connecting the Joystick on page 121 Part No 1148076 53 Pronto M51 Base with SureStep SECTION 9 BATTERIES 2 Position the front battery in the front of the battery tray 3 Position rear battery in rear of battery tray NOTE Ensure that both batteries are properly seated and resting on the battery tray 4 Connect the rear battery to the front battery RED and BLACK connectors 5 Connect the front battery to the controller BLACK connector 6 Reinstall the top shroud Refer to Removing Installing the Top Shroud on page 85 7 Perform one of the following Lower the seat assembly to the up position Refer to Tilting the Seat Assembly Formula CG Only on page 41 Install the seat assembly from the wheelchair Refer to Removing Installing the Seat Assembly on page 43 8 Lower the seat assembly to the down position Refer to Tilting the Seat Assembly Formula CG Only on page 41 9 Remove the battery shroud Refer to Removing Installing the Battery Shroud on page 47 10 Connect joystick cable not shown Refer to Disconnecting Connecting the Joystick on page 121 Battery Handle Batte
16. healthcare professional dealer or technical personnel before attempting to use this equipment otherwise injury or damage may occur Controller Settings Repair or Service Set up of the Electronic Control Unit is to be performed only by a qualified technician The final adjustments of the controller may affect other activities of the wheelchair Damage to the equipment could occur if improperly set up or adjusted Wheelchairs should be examined during maintenance for signs of corrosion water exposure incontinence etc Electrical components damaged by corrosion should be replaced IMMEDIATELY Wheelchairs that are used by incontinent users and or are frequently exposed to water may require replacement of electrical components more frequently Operation Information Performance adjustments should only be made by professionals of the healthcare field or persons fully conversant with this process and the driver s capabilities Incorrect settings could cause injury to the driver bystanders damage to the chair and to surrounding property After the wheelchair has been set up check to make sure that the wheelchair performs to the specifications entered during the set up procedure If the wheelchair does not perform to specifications turn the wheelchair Off immediately and reenter set up specifications Repeat this procedure until the wheelchair performs to specifications ALWAYS shift your weight in the direction you are turning DO
17. procedure refer to i E FIGURE 3 3 nu p 1 Position the wheelchair as close as possible along side the seat to which you are transferring with the rear casters pointing away from it Distance 2 After the wheelchair is positioned properly for transfer verify that the motor release levers are engaged Refer to Engaging Disengaging Motor FIGURE 3 3 Transferring To and From Release Lever on page 49 Other Seats 3 Flip back or remove arm on side of wheelchair you are transferring from 4 Shift body weight into seat with transfer During independent transfer little or no seat platform will be beneath you Use a transfer board if at all possible Pronto M51 Base with SureStep 20 Part No 1148076 SECTION 3 SAFETY HANDLING OF WHEELCHAIRS Reaching Leaning and Bending Forward NOTE For this procedure refer to FIGURE 3 4 Position the front and rear casters so that they are extended as far forward as possible and engage motor release levers WARNING DO NOT attempt to reach objects if you have to move forward in the seat or pick them up from the floor by reaching down between your knees FIGURE 3 4 Reaching Leaning and Bending Forward Reaching and Bending Backward WARNING DO NOT lean over the top of the back upholstery This will change your center of gravity and may cause you to tip over NOTE For this procedure refer to For this procedure refer to FIGURE 3 5 Positio
18. provider should determine whether this chair is suitable for the actual environment the chair will be used in DO NOT go down ramp at full speed FIGURE 3 1 Coping With Everyday Some seat back positions will cause Obstacles wheelchair to feel unstable 2 inch Bump or Threshold CAUTION Be aware of condition of ramp Traction will be diminished nonexistent on a slip pery surface Proceed with caution Part No 1148076 17 Pronto M51 Base with SureStep SECTION 3 SAFETY HANDLING OF WHEELCHAIRS A Note to Wheelchair Assistants When assistance to the wheelchair user is required remember to use good body mechanics Keep your back straight and bend your knees whenever tilting wheelchair or traversing curbs or other impediments Also be aware of detachable parts such as arms or legrests These must NEVER be used to move the wheelchair or as lifting supports as they may be inadvertently released resulting in possible injury to the user and or assistant s When learning a new assistance technique have an experienced assistant help you before attempting it alone Lifting Stairways WARNING DO NOT attempt to move an occupied power wheelchair between floors using a stairway Use an elevator to move an occupied power wheelchair between floors If moving a power wheelchair between floors by means of a stairway the occupant MUST be removed and transported independently of the power wheelchair Extreme caution is a
19. require activation of the switch immediately after the power switch is turned On in order to enter the drive mode The second line of the LCD will display PRESS RESET NOTE In these modes Standby Select allows the reset switch to be bypassed for users unable to activate the switch Memory Card Slot The memory card slot is used with the basic or professional memory card for saving or reading wheelchair parameters Pronto M51 Base with SureStep 38 Part No 1148076 Repositioning Joystick NOTE For this procedure refer to FIGURE 5 9 1 Turn the adjustment lock lever to release the joystick mounting tube from the mounting bracket 2 Remove the joystick from the wheelchair 3 Remove the three hex screws that secure both halves of the mounting bracket to the arm tube Reposition mounting bracket on opposite arm tube ensuring the threaded plate of the mounting bracket is on the inside of the arm tube as shown in FIGURE 5 9 SECTION 5 WHEELCHAIR OPERATION Mounting Bracket Mounting Threaded Plate Bracket Adjustment NOTE Lock Lever Joystick not shown Hex Mounting S oor Joystick Mounting Tube FIGURE 5 9 Repositioning Joystick Using the three hex mounting screws and washers secure both halves of the mounting bracket to the arm tube Slide the joystick mounting tube through the mounting bracket to the desired position Turn the adjustment lock lever to secure the joystick mo
20. 148076 45 Pronto M51 Base with SureStep SECTION 7 FOOTBOARD ASSEMBLY Bottom View of Set Screw Washer Footboard and Jam Nut Footboard Assembly 78 FIGURE 7 2 Adjusting the Footboard Assembly Angle o Depth NOTE For this procedure refer to FIGURE 7 3 1 Remove the quick release pin that secures the footboard assembly to the wheelchair frame WARNING Make sure the detent balls of the quick release pin are fully released and beyond the outer edge of the tube before operating the wheelchair Otherwise injury and or damage may result Keep detent balls clean 2 Adjust footboard to one of three mounting positions 3 Install the quick release pin Make sure the detent balls of the quick release pin are fully released and beyond the outer edge of the tube Detail A DETAIL A BOTTOM VIEW OF FOOTBOARD Three Depth Adjustment Holes Quick Release Pin Footboard D Mounting Hole Quick Detent Balls Release Pin Outer Edge of Tube FIGURE 7 3 Adjusting the Footboard Assembly Depth Pronto M51 Base with SureStep 46 Part No 1148076 SECTION 8 TOP SHROUD AND WHEELS SECTION 8 TOP SHROUD AND WHEELS WARNING After any adjustments repair or service and before use make sure that all attaching hardware is tightened securely otherwise injury o
21. ANT seulement for use with wheelchair in FORWARD facing direction only REQUIREMENTS OF SAE J2249 ADA P N 1134840 REV B P N 1134840 REV B FAVES ISO Op4 AND 205 Wheelchairs Without TRRO NOTE Auto style seat positioning strap shown This This seat chest positioning strap is NOT Cette ceinture de positionnement au niveau l b 1 l th 1 intended for occupant restraint in a du siege ou du den NEST PAS congue i vehicle and DOES NOT pour retenir l occupant dans un v hicule 15 also tne airline Conform with ANSV RESNA WG 19 If moteur en mouvement at NEST oye signs of wear appear positioning strap conforme la norme ceinture DOIT AUSSITOT style seat positioning strap MUST be replaced IMMEDIATELY stole prerie doe P N 1134811 REV B Part No 1148076 9 Pronto M51 Base with SureStep SECTION I GENERAL GUIDELINES SECTION 1 GENERAL GUIDELINES WARNING SECTION GENERAL GUIDELINES contains important information for the safe operation and use of this product DO NOT use this product or any available optional equipment without first completely reading and understanding these instructions and any additional instructional material such as Owner s Manuals Service Manuals or Instruction Sheets supplied with this product or optional equipment If you are unable to understand the Warnings Cautions or Instructions contact a
22. Batteries not charged Weak batteries Have charger checked Replace batteries if necessary Refer to Replacing Batteries on page 55 Motor chatters or runs irregular Electrical malfunction Contact Dealer Invacare for Service Joystick erratic or does not respond as desired Damaged motor coupling Electrical malfunction Controller programmed improperly Contact Dealer Invacare for Service Contact Dealer Invacare for Service Contact Dealer Invacare to have controller reprogrammed Wheelchair does not respond to commands Poor battery terminal connection Have terminals cleaned Power indicator off even after recharging Electrical malfunction Contact Dealer Invacare for Service Part No 1148076 27 Pronto M51 Base with SureStep SECTION 4 SAFETY INSPECTION TROUBLESHOOTING Checking Battery Charge Level The following Do s and Don ts are provided for your convenience and safety DON T Don t perform any installation or maintenance without first reading this manual DO Read and understand this manual and any service information that accompanies a battery and charger before operating the wheelchair Don t perform installation or maintenance of batteries in an area that could be damaged by battery spills Move the wheelchair to a work area before cleaning terminals or opening battery box Don t make it a habit to discharge b
23. EVER SHALL NOT EXTEND BEYOND THE DURATION OF THE EXPRESS WARRANTY PROVIDED HEREIN AND INVACARE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES WHATSOEVER SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGE OR LIMITATION OF HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE EXCLUSION AND LIMITATION MAY NOT BE APPLICABLE THIS WARRANTY SHALL BE EXTENDED TO COMPLY WITH STATE PROVINCIAL LAWS AND REQUIREMENTS Invacare Corporation www invacare com USA Canada One Invacare Way 570 Matheson Blvd E Unit 8 All rights reserved Trademarks are Elyria Ohio USA Mississauga Ontario identified by the symbols and All 44036 2125 L4Z 4G4 Canada trademarks are owned by or licensed to 800 333 6900 800 668 5324 Invacare Corporation unless otherwise noted Yes you can 9 2008 Invacare Corporation Part No 1148076 Rev C 3 08
24. K CAL VALUES displays and the wheelchair does not drive The joystick calibration values are outside of the expected range Error code E19 Recalibrate the joystick joystick throw procedure SPM NOT CONNECTED The MPJ or Display module is not communicating with the control module Error code E200 Check the connections between the joystick or display and the controller Turn the power off and then back on Replace the controller if necessary AN SPM Communications Fault displays and the wheelchair drives slowly The controller has determined a fault during a previous turn off process Error code E41 Turn the wheelchair off and back on ATTENDANT ACTIVE and jaw displays The Proportional or Digital Attendant control is active and can be used to drive the chair Error code W05 This is normal behavior Batteries draw excessive current when charging Battery failure Electrical malfunction Have batteries checked for shorted cell Replace if necessary Contact Dealer Invacare for service Battery indicator flashes the charge level is low immediately after recharge Battery failure Malfunctioning battery charger Electrical malfunction Check batteries for shorted cell Replace if necessary Contact Dealer Invacare for Service Contact Dealer Invacare for Service Battery indicator flashes the charge level is low too soon after being recharged
25. Owner s Operator and Maintenance Manual Pronto M51 Base with SureStep Formula CG Tilt Rehab Seating DEALER This manual MUST be given to the user of the product USER BEFORE using this product read this manual and save for future reference For more information regarding Invacare products parts and services please visit www invacare com Yes you can REFERENCE DOCUMENTS A WARNING A QUALIFIED TECHNICIAN MUST PERFORM THE INITIAL SET UP OF THIS WHEELCHAIR ALSO A QUALIFIED TECHNICIAN MUST PERFORM ALL PROCEDURES IN THE SERVICE MANUAL WHEELCHAIR USERS DO NOT SERVICE OR OPERATE THIS EQUIPMENT WITHOUT FIRST READING AND UNDERSTANDING 1 THE OWNER S OPERATOR AND MAINTENANCE MANUAL AND 2 THE SEATING SYSTEM S MANUAL IF APPLICABLE IF YOU ARE UNABLE TO UNDERSTAND THE WARNINGS CAUTIONS AND INSTRUCTIONS CONTACT INVACARE TECHNICAL SUPPORT BEFORE ATTEMPTING TO SERVICE OR OPERATE THIS EQUIPMENT OTHERWISE INJURY OR DAMAGE MAY RESULT DEALERS AND QUALIFIED TECHNICIANS DO NOT SERVICE OR OPERATE THIS EQUIPMENT WITHOUT FIRST READING AND UNDERSTANDING 1 THE OWNER S OPERATOR AND MAINTENANCE MANUAL 2 THE SERVICE MANUAL IF APPLICABLE AND 3 THE SEATING SYSTEM S MANUAL IF APPLICABLE IF YOU ARE UNABLE TO UNDERSTAND THE WARNINGS CAUTIONS AND INSTRUCTIONS CONTACT INVACARE TECHNICAL SUPPORT BEFORE ATTEMPTING TO SERVICE OR OPERATE THIS EQUIPMENT OTHERWISE INJURY OR DAMAGE MAY RESUL
26. STICK ACTION MPJ Move the On Off switch Forward to the On position SPJ Press the On Off button 2 Turning the power Off can be achieved by performing one of the following steps JOYSTICK ACTION MPJ Move the On Off switch Back to the Off position SPJ Press the On Off button SPJ Joysticks MPJ Joystick CG ONLY On Off On Off Button Switch FIGURE 5 1 Turning the Power On Off Part No 1148076 29 Pronto M51 Base with SureStep SECTION 5 WHEELCHAIR OPERATION Using the Joystick to Drive the Wheelchair NOTE For this procedure refer to FIGURE 5 2 The joystick is located on the joystick housing and provides smooth control of speed and direction It is equipped with 360 degrees of mobility for ease of operation The joystick is spring loaded and automatically returns to the upright neutral position when released Pushing the joystick in a given direction causes the wheelchair to move in that direction The joystick has proportional drive control meaning that the further it is pushed from the upright neutral position the faster the wheelchair moves The maximum speed however is limited by the setting of the speed control knob To slow the wheelchair to a stop simply release the joystick The wheelchair has automatic speed and direction compensation to minimize corrections When first learning to drive select a slow speed and try to drive the wheelchair as slowly as possible
27. Step SECTION GENERAL GUIDELINES Batteries The warranty and performance specifications contained in this manual are based on the use of deep cycle gel cell or sealed lead acid batteries Invacare strongly recommends their use as the power source for this unit Carefully read battery battery charger information prior to installing servicing or operating your wheelchair Charging Batteries A DANGER When using an extension cord use only a three wire extension cord having at least 16 AWG American Wire Gauge wire and the same or higher electrical rating as the device being connected Use of improper extension cord could result in risk of fire and electric shock Three prong to two prong adapters should not be used Use of three prong adapters can result in improper grounding and present a shock hazard to the user NEVER attempt to recharge the batteries by attaching cables directly to the battery terminals DO NOT attempt to recharge the batteries and operate the wheelchair at the same time DO NOT operate wheelchair with extension cord attached to the AC cable DO NOT attempt to recharge the batteries when the wheelchair has been exposed to any type of moisture DO NOT attempt to recharge the batteries when the wheelchair is outside DO NOT sit in the wheelchair while charging the batteries DO NOT attempt to recharge batteries using both the on board battery charger and an independent battery charger plugged int
28. T REFERENCE DOCUMENTS M50 51 61 Service Manual 1125075 Formula CG Powered Seating Owner s Manual 1143155 Adjustable ASBA Seats Owner s Manual 1143192 Adjustable ASBA Seat Service Manual 1143238 Van Seat Owner s Manual 1143195 MK6i Electronics Field Reference Guide 1141471 NOTE Updated versions of this manual are available on www invacare com Pronto M51 Base with SureStep 2 Part No 1148076 TABLE OF CONTENTS TABLE OF CONTENTS REFERENCE DOCUMENTS 66 REGISTER YOUR PRODUCT cccccccccccccccccccccccccccccssccccccccccccccccccccccccccs SPECIAL NOTES D TYPICAL PRODUCT PARAMETERS 66 7 LABEL LOCATION 6 6 Wheelchairs etin decus Meinen 9 Wheelchairs Without TRRO tient t tanie 9 SECTION 1 GENERAL GUIDELINES 666 10 Controller Settings Repair Service 10 Operation Information sese ast nn ne Turenne ini na test 10 ACCESSOrISS oem mine E Batteries sense anna nine ieissa 12 GEOBRGIDe InsEFD CHIOTS reddit 13 R
29. TANT THAT YOU READ THIS INFORMATION REGARDING THE POSSIBLE EFFECTS OF ELECTROMAGNETIC INTERFERENCE ON YOUR POWERED WHEELCHAIR Electromagnetic Interference EMI From Radio Wave Sources Powered wheelchairs and motorized scooters in this text both will be referred to as powered wheelchairs may be susceptible to electromagnetic interference EMI which is interfering electromagnetic energy EM emitted from sources such as radio stations TV stations amateur radio HAM transmitters two way radios and cellular phones The interference from radio wave sources can cause the powered wheelchair to release its brakes move by itself or move in unintended directions It can also permanently damage the powered wheelchair s control system The intensity of the interfering EM energy can be measured in volts per meter V m Each powered wheelchair can resist EMI up to a certain intensity This is called its immunity level The higher the immunity level the greater the protection At this time current technology is capable of achieving at least a 20 V m immunity level which would provide useful protection from the more common sources of radiated EMI There are a number of sources of relatively intense electromagnetic fields in the everyday environment Some of these sources are obvious and easy to avoid Others are not apparent and exposure is unavoidable However we believe that by following the warnings listed below your risk to EMI will
30. This screen displays the software version and date information After this screen the joystick displays the Main Screen FIGURE 5 5 LCD Display Screens Splash Screen Main Screen NOTE For this information refer to FIGURE 5 6 on page 36 During normal operation the active drive is displayed in the upper half of the LCD display Battery charge level is shown in the Battery Gauge Display BGD located on the right side of the LCD display At full charge solid blocks fill in all ten segments between E Empty and F Full As the battery becomes discharged the top most segments will progressively disappear until no segments appear between E and F At this level the user should charge the batteries as soon as possible The lower half of the LCD display is the Information Center The Information Center displays current data on the wheelchair Refer to LCD Display table on page 35 for descriptions of information shown LCD DISPLAY ITEM DESCRIPTION DRIVE NAME This field shows the currently selected Drive s Name Available choices are as follows Drive 1 Drive 2 Drive 3 Drive 4 X Drive selected via the programmer NOTE Drive names can be customized Actual drive names may display differently BATTERY LEVEL This symbol shows the Battery Level and will change depending on the available INDICATOR battery power This indicator is shown on every screen STATUS MESSAGE This area displays status or ins
31. acid will not spill It also helps to prolong the life of the battery DO NOT tip the batteries Keep the batteries in an upright position NOTE For this procedure refer to FIGURE 9 2 on page 54 NOTE If there is battery acid in the bottom of the battery tray or on the sides of the battery apply baking soda to these areas to neutralize the battery acid Before reinstalling the existing or new battery clean the baking soda from the battery tray or battery being sure to avoid contact with skin and eyes Determine source of contamination NEVER install reinstall a battery with a cracked or otherwise damaged case NOTE Have the following tools available TOOL ar conan 7 16 INCH 6PT BOX WRENCH Not Supplied DIAGONAL CUTTERS Not Supplied Removing 1 Place the wheelchair in a well ventilated area where work can be performed without risking damage to carpeting or floor covering 2 Verify the joystick On Off switch is in the Off position and disconnect joystick cable not shown Refer to Disconnecting Connecting the Joystick on page 121 3 Perform one of the following e Tilt the seat assembly to the up position Refer to Tilting the Seat Assembly Formula CG Only on page 41 Remove the seat assembly from the wheelchair Refer to Removing Installing the Seat Assembly on page 43 4 Remove the battery shroud Refer to Removing Installing the Battery Shroud on page 47 5 Disconnect the front battery from the
32. ain Fest iuueni PT RS D A Le tau ct IE PU 13 VVeisht Tita INAS ede ST De ee 13 hai aci E 13 SECTION 2 EMI INFORMATION 00000000000000000000000000000000000000000000000000000 14 SECTION 3 SAFETY HANDLING OF WHEELCHAIRS 16 Stability and Balance 16 Coping With Everyday ObStacles o ce torte 17 Note to Wheelchair Assistants e cute Lies ti nn 18 Lifting Stall WAYS nn melon lanta en EEA EEEN 18 Transferring and From Other Seats menant aie 20 Reaching Leaning and Bending Forward ss 21 Reaching and Bending BackWald Ves Ie iple 21 SECTION 4 SAFETY INSPECTION TROUBLESHOOTING 22 Safety Inspection Checklists ne betta vehi otov ne T eode i reis 22 Troubleshooting Guide anodin sine 23 Checking Battery Charge Level rte ritiro aini a nana de 28 SECTION 5 WHEELCHAIR OPERATION 66 29 Operating the Wheelchait itinere nn nent tn estelle 29 MKei SPJ w PSS and MK6i SPJ w ACC Joystick Switches and Indicators 3l Joystick Switches and Indicators aan Reg cubi 33 dei ee 39 Disconnecting Connecting the Joysticks 1 1 oen inner 40 SECTION 6 SEAT 666 FI Tilting the Seat Assemb
33. aps up onto the battery cables FIGURE 9 3 4 Disconnect POSITIVE battery cable from the POSITIVE battery terminal FIGURE 9 3 5 Disconnect NEGATIVE battery cable from NEGATIVE battery terminal FIGURE 9 3 When to Charge Batteries SPJ w PSS and SPJ w ACC Joysticks NOTE For this procedure refer to FIGURE 9 4 The Information Gauge Display located on the front of the joystick housing it provides the state of battery charge including notification of when the battery requires charging It also provides the following information to the user on the status of the wheelchair A GREEN LEDs are lit indicating well Information Gauge Display charged batteries B AMBER LEDs are lit indicating batteries are moderately charged Recharge batteries before taking a Empty a Batteries Full RED LEDs are indicating Battery Charger batteries are running out of charge PE Programming Port FIGURE 9 4 SPJ w PSS and SPJ w ACC possible Joysticks Part No 1148076 57 Pronto M51 Base with SureStep SECTION 9 BATTERIES MPJ Joystick NOTE For this procedure refer to FIGURE 9 5 The far right side of the display screen is the Battery Gauge Display BGD It provides information on the remaining charge in the batteries At full charge solid blocks fill in all ten segments between E Empty and F Full OUTDOOR
34. atteries to the lowest level Recharge as frequently as possible to maintain a high charge level and extend battery life Don t use randomly chosen batteries or chargers Follow recommendations in this manual when selecting a battery or charger Don t put new batteries into service before charging Fully charge a new battery before using Don t tip or tilt batteries Use a carrying strap to remove move or install a battery Don t tap on clamps and terminals with tools Push battery clamps on the terminals Spread clamps wider if necessary Don t mismatch your battery and chargers Use ONLY a GEL charger for a GEL battery Pronto M51 Base with SureStep 28 Part No 1148076 SECTION 5 WHEELCHAIR OPERATION SECTION 5 WHEELCHAIR OPERATION WARNING After ANY adjustments repair or service and before use make sure that all attaching hardware is tightened securely otherwise injury or damage may result Set up of the Electronic Control Unit is to be performed only by a qualified techni cian The final adjustments of the controller may affect other activities of the wheel chair Damage to the equipment could occur under these circumstances Operating the Wheelchair Turning the Power On Off NOTE For this procedure refer to FIGURE 5 1 NOTE MP Joystick available on Formula CG seating system only 1 To turn the power On perform one of the following steps JOY
35. attery Terminal Cap RED Connectors Mounting Screw NEGATIVE Battery Terminal Cap NEGATIVE Battery Cable NEGATIVE Battery terminal BLACK Connectors POSITIVE Battery Cable L Bracket with Mounting Screw Locknuts POSITIVE Battery termina NOTE Handles on batteries removed for clarity UI Battery DETAIL B RED Connectors POSITIVE NEGATIVE Battery E Battery Terminal BLACK Termina Connector to Controller Plug into Tie wraps BLACK UI Battery Connectors LH 3 UI Batteries NOTE Handles on batteries removed for clarity FIGURE 9 3 Connecting Disconnecting Battery Cables 56 Part No 1148076 Pronto M51 Base with SureStep SECTION 9 BATTERIES Disconnecting Battery Cables WARNING The use of rubber gloves is recommended when working with batteries NEVER allow any of your tools and or battery cables to contact both battery terminals at the same time An electrical short may occur and serious personal injury or damage may occur NOTE For this procedure refer to FIGURE 9 3 on page 56 1 Remove the batteries Refer to Removing Installing Batteries from into Battery Tray on page 53 2 Cut the tie wrap that secures the battery terminal cap in place Detail B of FIGURE 9 3 3 Slide terminal c
36. by pushing the joystick slightly forward This exercise will help you learn to utilize the full potential of the proportional control and allow you to start and stop smoothly To drive the wheelchair perform the following 1 Adjust speed control knob to the appropriate setting 2 Turn the power On Refer to Turning the Power On Off on page 29 3 Maneuver the joystick in the following manner MOVEMENT ACTION To Move To Move Push joystick forward towards Left Forward the front of the wheelchair F t of Pull joystick back towards the rear of the wheelchair To Move Turn RIGHT Move joystick toward the right To Move Right side of the wheelchair Backward Turn LEFT Move joystick toward the left side of the wheelchair Rear of Joystick STOP Release the joystick and the Wheelchair IE ae Nees FIGURE 5 2 Using the Joystick to Drive the Wheelchair NOTE For specific information about the joystick installed on the wheelchair refer to one of these procedures e SPJ w PSS and MK6i SPJ w ACC Joystick Switches and Indicators on page 31 e MPJ Joystick Switches and Indicators on page 33 Pronto M51 Base with SureStep 30 Part No 1148076 SECTION 5 WHEELCHAIR OPERATION MK i SPJ w PSS and SPJ w ACC Joystick Switches and Indicators NOTE For this procedure refer to FIGURE 5 3 Information Gauge Display On Off Button Mode Butto
37. cure the joystick connector to the other connectors FIGURE 5 11 Disconnecting Connecting the Joysticks MPJ Joysticks Pronto M51 Base with SureStep 40 Part No 1148076 SECTION 6 SEAT SECTION 6 SEAT WARNING After ANY adjustments repair or service and BEFORE use make sure that all attaching hardware is tightened securely otherwise injury or damage may result Before performing any maintenance adjustment or service verify that ON OFF switch on the joystick is in the OFF position Tilting the Seat Assembly Formula CG Only WARNING Make sure power to the wheelchair is OFF before performing this procedure Never leave the seat assembly in the UP OPEN position unless necessary to perform a a procedure on the wheelchair otherwise injury or damage may result After ANY adjustments repair or service and before use make sure all attaching hardware is tightened securely otherwise injury or damage may result NOTE For this procedure refer to FIGURE 6 1 on page 42 NOTE Removing the seat is not necessary to access the battery compartment on wheelchairs equipped with a Formula CG seating system The seat assembly tilts back and props into place to provide access to the batteries and the underside of the seat Tilting the Seat Assembly Back 1 Place the wheelchair in a well ventilated area where work can be performed without risking damage to carpeting or floor covering N Ensure the s
38. curing the Wheelchair the Vehicle 64 Securing the EEE 66 NOTES 0000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 69 LIMITED WARRANTY 000000000000000000000000000000000000000000000000000000000000000000000 72 REGISTER YOUR PRODUCT The benefits of registering include Safeguarding your investment 2 Ensuring long term maintenance and servicing of your product 3 Receiving updates with product information maintenance tips and industry news Register ONLINE at warranty invacare com Please have your model number and purchase date available to complete your registration Any registration information you submit will only be used by Invacare Corporation and protected as required by applicable laws and regulations Pronto M51 Base with 4 Part No 1148076 SPECIAL NOTES SPECIAL NOTES Signal words are used in this manual and apply to hazards or unsafe practices which could result in personal injury or property damage Refer to the table below for definitions of the signal words SIGNAL WORD MEANING Danger indicates an imminently hazardous situation which if not DANGER avoided will result in death or serious injury Warning indicates a potentially hazardous situation which if not WARNING avoided could result in death or serious injury Caution indicates a potentially hazardous situation which if not CAUTION avoided may r
39. d As the battery becomes discharged the E segments will progressively disappear a LL A Battery Gage bar at a time until no segments appear TILT WARNING Display between E and F At this level the user should charge the batteries as soon as possible FIGURE 9 5 MPJ Joystick Charging Batteries WARNING NEVER attempt to recharge the batteries by attaching cables directly to the battery terminals DO NOT attempt to recharge the batteries and operate the wheelchair at the same time DO NOT attempt to recharge the batteries when the wheelchair has been exposed to any type of moisture DO NOT attempt to recharge the batteries when the wheelchair is outside DO NOT sit in the wheelchair while recharging the batteries DO NOT attempt to recharge the batteries using both the on board battery charger and an independent battery charger plugged into the joystick charger port at the same time Doing so will reduce the life of the batteries Read and carefully follow the individual instructions for each charger supplied or purchased If charging instructions are not supplied consult a qualified technician for proper procedures CAUTION New batteries MUST be fully charged prior to initial use of the wheelchair ALWAYS charge new batteries before initial use or battery life will be reduced As a general rule you should recharge your batteries as frequently as possible to assure the longest possible life and to mini
40. dvised when it is necessary to move an unoccupied power wheelchair up or down the stairs Invacare recommends using two assistants and making thorough preparations Use only secure nondetachable parts for hand hold supports It is strongly recommended to lift the wheelchair only by the rear frame and the front forks otherwise injury or damage may occur DO NOT attempt to lift the wheelchair by any removable detachable parts Lifting by means of any removable detachable parts of a wheelchair may result in injury to the user or damage to the wheelchair The weight of the wheelchair with batteries and without the user is 212 Ibs Use proper lifting techniques lift with your legs to avoid injury NOTE For this procedure refer to FIGURE 3 2 on page 19 Follow this procedure for moving the wheelchair between floors when an elevator is not available or lifting the wheelchair is necessary Pronto M51 Base with SureStep 18 Part No 1148076 SECTION 3 SAFETY HANDLING OF WHEELCHAIRS NOTE When using a stairway to move the wheelchair seat and any accessories move all wheelchair components away from the stairway prior to reassembly NOTE This procedure needs two assistants to lift the wheelchair to transport it Remove the occupant from the wheelchair Remove the seat Refer to Tilting the Seat Assembly Formula CG Only on page 42 Remove any accessories on the wheelchair Bend your knees and keep your back straight Ensu
41. e the Department of Transportation has not approved any tie down systems for transportation of a user while in a wheelchair in a moving vehicle of any type It is Invacare s position that users of wheelchairs should be transferred into appropriate seating in vehicles for transportation and use be made of the restraints made available by the auto industry Invacare cannot and does not recommend any wheelchair transportation systems Compliance Information This wheelchair conforms with the requirements of the ANSI RESNA WC Vol 1 Section 19 NOTE ANSI American National Standards Institute RESNA Rehabilitation Engineering and Assistive Technology Society of North America This wheelchair has been dynamically tested in a forward facing mode with the specified crash test dummy which corresponds to a person with a weight of 114 209 pounds restrained by BOTH pelvic and upper torso belts in accordance with ANSI RESNA WC Vol 1 Section 19 BOTH pelvic and upper torso belts should be used to reduce the possibility of head and chest impacts with vehicle components Specifications MODEL WHEELCHAIR WEIGHT LIMIT Part No 1148076 63 Pronto M51 Base with SureStep SECTION 10 TRANSPORT READY PACKAGE Securing the Wheelchair to the Vehicle Positioning the Wheelchair in the Vehicle WARNING This wheelchair must be in a forward facing position during travel in a motor vehicle The recommended clear zones for wheelchair sea
42. e obtained from SAE International 400 Commonwealth Drive Warrendale PA 15096 0001 877 606 7232 or 724 776 4970 Attach WTORS to the tie down brackets in accordance with the manufacturer s instructions and SAE J2249 Part No 1148076 65 Pronto M51 Base with SureStep SECTION 10 TRANSPORT READY PACKAGE Securing the Occupant Wheelchair Anchored Belts WARNING The pelvic belt that is provided by Invacare has been tested for use in a motor vehi cle on this wheelchair ONLY DO NOT replace the pelvic belt with a different style pelvic belt NOTE For this procedure refer to FIGURE 10 2 The wheelchair has been provided with a pelvic belt which meets the requirements of ANSI RESNA W C 19 The pelvic belt provided by Invacare has been designed to accommodate use on either side of the vehicle If necessary follow the instructions below to reverse the orientation of the pelvic belt to accommodate the vehicle anchored upper torso belt 1 Install the pelvic belt pin Detail A into the large end of the slot in the belt mounting bracket Rotate downward and forward until it snaps into place into the small end of the slot NOTE Note the position of the male end of the belt when installing the pelvic belt onto the belt mounting brackets The male end of the pelvic belt Detail A has a pin which is used to secure the vehicle anchored upper torso belt 2 Repeat STEP 1 for the opposite belt mounting bracket
43. eating system is in the fully upright position See Formula CG seating system manual shipped with wheel chair 3 Verify the joystick On Off switch is in the Off position and disconnect joystick cable 4 Engage the motor release levers Refer to Engaging Disengaging Motor Release Lever on page 80 Remove front rigging See Formula CG seating system manual shipped with wheelchair D Remove the two screws and locknuts securing the seating assembly to the front seat posts N Firmly grasp the front edge of the seat assembly slowly tilt the seat assembly back into the Up Open position Remove prop rod from the clip located on the seating assembly and engage the prop rod end into the front seat post as shown in FIGURE 6 1 Part No 1148076 41 Pronto M51 Base with 5 SECTION 6 SEAT 9 Gently allow weight of seat assembly to be supported by the prop rod NOTE Only leave the seat assembly in the Up Open position while performing any necessary procedures Always lower the seat assembly to the Down Closed position when not servicing the wheelchair Ensure the seat is locked in place before using Tilting the Seat Assembly Forward 1 Using one hand firmly grasp the front edge of the seat assembly and lift until seat assembly is no longer supported by the prop rod N Disengage the prop rod from the front seat post and secure into clip M Using both hands slowly tilt the seat assembly Forward
44. ery cables to the battery the battery cables MUST be connected to the battery terminals as shown in Detail of FIGURE 9 3 depending on battery type otherwise damage to the battery cable may result when installing battery terminal caps NOTE For this procedure refer to FIGURE 9 3 on page 56 1 Secure the battery cables to the battery terminals as described below Securely tighten Refer to Detail A of FIGURE 9 3 A Secure NEGATIVE battery cable to the NEGATIVE battery terminal using the mounting screw and the locknut B Secure the POSITIVE battery cable to the POSITIVE battery terminal using the L bracket with mounting screw and the locknut N Verify all battery cables are correctly installed and securely tightened 3 Slide terminal caps down battery cables and onto battery terminals m Secure each terminal cap in place with a tie wrap use tie wraps 11 1 2 inches long Detail of FIGURE 9 3 Position the batteries into the wheelchair Refer to Removing Installing Batteries from into Battery Tray on page 53 g Part No 1148076 55 Pronto M51 Base with SureStep SECTION 9 BATTERIES NOTE New batteries MUST be fully charged before using otherwise the life of the batteries will be reduced 6 If necessary charge the battery Refer to Charging Batteries on page 58 DETAIL A NOTE Battery terminal caps not shown on front battery for clarity POSITIVE B
45. esult in property damage minor injury or both NOTICE THE INFORMATION CONTAINED IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE WHEELCHAIR USER As a manufacturer of wheelchairs Invacare endeavors to supply a wide variety of wheelchairs to meet many needs of the end user However final selection of the type of wheelchair to be used by an individual rests solely with the user and his her healthcare professional capable of making such a selection WHEELCHAIR TIE DOWN RESTRAINTS AND SEAT RESTRAINTS TRRO OR TRBKTS TRRO includes four factory installed transport brackets and a wheelchair anchored pelvic belt TRRO has been crash tested in accordance with ANSI RESNA WC Vol Section 19 Frontal Impact Test requirements for wheelchairs with a 168 Ib crash dummy which corresponds to a person with a weight of 114 to 209 Ibs TRBKTS includes four factory installed wheelchair transport brackets TRBKTS has not been crash tested in accordance with WC 19 Use these transport brackets only to secure an unoccupied wheelchair during transport As of this date the U S Department of Transportation has not approved any tie down systems for transportation of a user while in a wheelchair in a moving vehicle of any type It is Invacare s position that users of wheelchairs should be transferred into appropriate seating in vehicles for transportation and use be made of the restraints made available by the auto industry Invacare cannot and d
46. g devices and or strap s should not be relied on for occupant restraint These items may be used IN ADDITION TO the wheelchair anchored or vehicle anchored belts Wheelchairs with adjustable seat angles MUST be set to 10 DO NOT alter or substitute wheelchair frame parts components or seating systems A sudden stop and or collision may structurally damage your wheelchair Wheelchairs involved in such incidents should be replaced Spill proof batteries such as gel cells should be installed on wheelchairs to be used during travel in a motor vehicle TRANSPORT READY PACKAGES ARE NOT RETROFITTABLE TO EXISTING MODELS AND ARE NOT FIELD SERVICEABLE Pronto M51 Base with SureStep 62 Part No 1148076 SECTION 10 TRANSPORT READY PACKAGE A WARNING Only use the transport brackets included with TRRO and TRBKTS for the purposes described in this manual About Transport Ready Packages TRRO includes four factory installed transport brackets and a wheelchair anchored pelvic belt TRRO has been crash tested in accordance with ANSI RESNA WC Vol 1 Section 19 Frontal Impact Test requirements for wheelchairs with a 168 lb crash dummy which corresponds to a person with a weight of 114 to 209 Ibs TRBKTS includes four factory installed wheelchair transport brackets TRBKTS has not been crash tested in accordance with WC 19 Use these transport brackets only to secure an unoccupied wheelchair during transport As of this dat
47. g of the flash codes and what they indicate Pronto M51 Base with SureStep 32 Part No 1148076 SECTION 5 WHEELCHAIR OPERATION Information Gauge Display The information gauge display is located on the front of the joystick housing and provides the following information to the user on the status of the wheelchair 1 Power is On 2 True state of battery charge including notification of when the battery requires charging A GREEN LEDs are lit indicating well charged batteries B AMBER LEDs are lit indicating batteries are moderately charged Recharge batteries before taking a long trip RED LEDs are lit indicating batteries are running out of charge Recharge batteries as soon as possible The Information Gauge display also serves as a system diagnostic device when a fault is detected by the control module A specific number of flashes of the LEDs indicate the type of fault detected Refer to Service Indicator Light Diagnostics on page 30 for the diagnostic indications of the wheelchair status MPJ Joystick Switches and Indicators NOTE For this procedure refer to FIGURE 5 4 on page 34 NOTE MP Joystick available on Formula CG seating system only Drive Select Toggle Switch The drive select toggle switch is located on the left side below the LCD The drive select position is momentary meaning that it will return to the neutral position after a selection is made This switch allows the operator to selec
48. ge wire and the same or higher electrical rating as the device being connected Use of improper extension cord could result in risk of fire and electric shock Three prong to two prong adapters should not be used Use of three prong adapters can result in improper grounding and present a shock hazard to the user WARNING Ensure the pins of the extension cord plug are the same number size and shape as those on the charger DO NOT under any circumstances cut or remove the round grounding plug from the charger AC cable plug or the extension cord plug NOTE For this procedure refer to FIGURE 9 6 on page 60 NOTE The On Off LED indicator light and the charger LED indicator light are located on the top of the charger on the rear of the wheelchair Open rear shroud to view indicator lights NOTE If the batteries are completely discharged the charger will not charge them Replace the batteries Refer to Removing Installing Batteries from into Battery Tray on page 53 Part No 1148076 59 Pronto M51 Base with SureStep SECTION 9 BATTERIES Plug the female connector of the AC power cord supplied to the AC receptacle on the charger and plug in the male connector on the AC power cord into the wall outlet N The On Off LED indicator is blinking RED this is abnormal Unplug AC power cord from the on board battery charger and wall outlet Charger may need to be replaced Contact an Invacare dealer or qualified technic
49. ian 3 When the On Off LED indicator light is Off charger is Off 4 When the Charge LED indicator light is YELLOW the batteries are charging 5 When the Charge LED indicator light is solid GREEN the batteries are fully charged as their condition will allow D When charging is complete unplug the male connector of the AC power cord from the wall outlet and then unplug the female connector of the AC power cord from the AC receptacle on the charger A WARNING DO NOT operate wheelchair with AC power cord attached to the wheelchair AC Receptacle Charger on Charger Female Connector on Hidden from Vi AC Power Cord en ower Connects to Cord Connects to Receptacle on Charger Wall Outlet To Wall Outlet Male Connector ON OFF INDICATOR STATUS SOLID RED Charger On BLINKING RED Abnormal LED OFF Charger Off CHARGING INDICATOR STATUS YELLOW Charging SOLID GREEN Fully charged FIGURE 9 6 On Board Battery Charger Pronto M51 Base with SureStep 60 Part No 1148076 SECTION 9 BATTERIES Charging Using An Independent Charger Plugged Into The Joystick WARNING Read and carefully follow the individual instructions for each charger supplied or purchased If charging instructions are not supplied consult a qualified technician for proper procedures DO NOT attempt to recharge the batteries using both the on board battery
50. ienced by the user may be different from other chairs previously used This power wheelchair has Invacare s SureStep technology a feature that provides the chair with optimum traction and stability when driving forward over transitions and thresholds of up to 2 inches The following warnings apply specifically to the SureStep Feature DO NOT use on inclines greater than 9 DO NOT use on inclines with wet slippery icy or oily surfaces This may include certain painted or otherwise treated wood surfaces DO NOT traverse down ramps at high speed Doing so will reduce traction and increase stopping distance The end user s weight can materially affect traction on sloped surfaces Great care should be taken when traversing such slopes To determine and establish your particular safety limits practice use of this product on various sloping surfaces in the presence of a qualified healthcare provider before attempting active use of this wheelchair Other general warnings listed within this document also apply Wheelchairs should be examined during maintenance for signs of corrosion water exposure incontinence etc Electrical components damaged by corrosion should be replaced IMMEDIATELY Wheelchairs that are used by incontinent users and or are frequently exposed to water may require replacement of electrical components more frequently Pronto M51 Base with SureStep 6 Part No 1148076 TYPICAL PRODUCT PARAMETERS
51. into the Down Closed position WARNING Ensure the two screws are fully engaged and the seat assembly is securely locked in place before use otherwise injury or damage may result 4 Using the two screws and locknuts secure the seat assembly to the two front seat posts Seat Assembly Screw Locknut ee FIGURE 6 1 Tilting the Seat Assembly Formula CG Only Pronto M51 Base with SureStep 42 Part No 1148076 SECTION 6 SEAT Removing Installing the Seat Assembly NOTE For this procedure refer to FIGURE 6 2 NOTE This procedure is for wheelchairs WITHOUT the Formula PTO Plus seating system installed ONLY For wheelchairs with the Formula PTO Plus seating system refer to Tilting the Seat Assembly Formula CG Only on page 41 Removing 1 Disconnect the joystick cable at rear of seat Refer to Disconnecting Connecting the loysticks on page 44 Push down on the latch bar underneath front of seat N 3 Rotate seat assembly backward 4 Slide the seat assembly forward to disengage seat from pivot brackets located in the rear Installing 1 Position the seat in the rear pivot brackets as shown in FIGURE 6 2 2 Rotate seat assembly forward 3 When seat is lowered engage seat brackets into seat clevis pins A WARNING When reinstalling the seat verify that the seat brackets are engaged with the seat clevis pins by pulling up on the latch bar 4 Pull up on latch bar to verify that
52. ize and or voltage may cause damage to your wheelchair and give you unsatisfactory performance ALWAYS use a battery handle lifting strap when lifting a battery It is the most convenient method and assures that the battery acid will not spill It also helps to prolong the life of the battery DO NOT tip the batteries Keep the batteries in an upright position NEVER allow any of your tools and or battery cables to contact both battery posts at the same time An electrical short may occur and serious personal injury or damage may occur The POSITIVE battery cable MUST connect to the POSITIVE battery terminal otherwise serious damage will occur to the electrical system Connect same color connectors to each other RED to RED BLACK to BLACK DO NOT remove fuse or mounting hardware from POSITIVE battery cable mounting screw To replace the fuse obtain and replace battery harness with fuse Wheelchairs should be examined during maintenance for signs of corrosion water exposure incontinence etc Electrical components damaged by corrosion should be replaced IMMEDIATELY Wheelchairs that are used by incontinent users and or are frequently exposed to water may require replacement of electrical components more frequently NOTE If there is battery acid in the bottom of the battery tray or on the sides of the battery apply baking soda to these areas to neutralize the battery acid Before reinstalling the existing or new batter
53. ly Formula CG Only rennes 4 Removing Installing the Seat Assembly nn 43 SECTION 7 FOOTBOARD ASSEMBLY cccccccccccccccccccccccccccccsccocccccccces 44 Removing Installing the Footboard Assembly 44 Adjusting the Footboard Assembly nn Ut dette epe etse bn 45 Part No 1148076 3 Pronto M51 Base with SureStep TABLE OF CONTENTS TABLE OF CONTENTS SECTION 8 TOP SHROUD AND WHEELS 00000000000000000000000000000000000000000 47 Replacing the Flat Free Tires on the Wheel Rim ss 47 Removing Installing the Battery Shroud sn 47 Engaging Disengaging Motor Release Lever sn 49 Replacing Front Rear Caster Assemblies nn 50 Adjusting FOP A NA 50 SECTION 9 BATTERIES 666 DI Warnings For Handling and Replacing Batteries 5 Using the Proper Batteries tte etienne 52 Removing Installing Batteries from into Battery Tray ss 53 Connecting Disconnecting Battery Cables 55 When to Charge Batteries mme 57 Charging Batteries ad dud io pa den dedere eee eet 58 Battery nan side bn pato 59 SECTION 10 TRANSPORT READY PACKAGE 62 About Transport Ready Packages anses 63 Compliance Informations es 63 Se
54. mize required charging time Plan to recharge them when you do not anticipate using the wheelchair Basic concepts which will help you understand this automatic process are Pronto M51 Base with SureStep 58 Part No 1148076 SECTION 9 BATTERIES The amount of electrical current drawn within a given time to charge a battery is called charge rate If due to usage the charge stored in the battery is low the charge rate is high As a charge builds up the charge rate is reduced and the battery charger rate decreases to a trickle charge NOTE If the batteries need to be charged more often or take longer to charge than normal they may need to be replaced Contact a qualified technician NOTE The batteries can be charged using the on board battery charger or by plugging an independent battery charger into the port located on the front of the joystick Battery Charger Operation DANGER Use of improper extension cord could result in risk of fire and electric shock WARNING Read and carefully follow the manufacturer s instructions for each charger supplied or purchased If charging instructions are not supplied consult a qualified technician for proper procedures NEVER leave the charger unattended when the charger circuit breaker is tripping On Board Battery Charger DANGER When using an extension cord use only a three wire extension cord having at least 16 AWG American Wire Gau
55. n Decrease Speed Button Tortoise Speedometer Active Increase Speed Button Hare Additional Input for Powered Seating Switch DETAIL A FRONT VIEW Service Indicator Charger Programming Input NOTE The mode button is only present on SPJ w ACC joystick FIGURE 5 3 MK6i w PSS and MK6i SPJ w ACC Joystick Switches and Indicators On Off Button This button is located at the front of the joystick housing It is used to turn the wheelchair On and Off to remove the joystick from sleep mode if programmed and to lock or unlock the joystick if programmed Speedometer The speedometer is used to show the maximum speed The right most LED indicates current maximum speed setting The bottom left GREEN LED flashes to indicate that the joystick is in speed limit mode Speed limit mode limits the drive speed to a pre programmed value typically when the seat has been elevated and the wheelchair is required to drive at 20 speed Part No 1148076 31 Pronto M51 Base with SureStep SECTION 5 WHEELCHAIR OPERATION Speed Control Buttons The speed control buttons tortoise button and hare button are used to set and adjust the maximum speed 1 To adjust the speed perform one of the following e Adjust Speed in 20 Increments 5 Speed Mode Press the tortoise button gt or hare button ey to decrease increa
56. n wheelchair as close as possible to the desired object Point the front AND rear casters rearward to create the longest possible wheelbase Reach back only as far as your arm will extend without changing your sitting position FIGURE 3 5 Reaching and Bending Backward Part No 1148076 21 Pronto M51 Base with SureStep SECTION 4 SAFETY INSPECTION TROUBLESHOOTING SECTION 4 SAFETY INSPECTION TROUBLESHOOTING NOTE Every six months or as necessary take your wheelchair to a qualified dealer for a thorough inspection and servicing Regular cleaning will reveal loose or worn parts and enhance the smooth operation of your wheelchair To operate properly and safely your wheelchair must be cared for just like any other vehicle Routine maintenance will extend the life and efficiency of your wheelchair Safety Inspection Checklists CAUTION As with any vehicle wheels and tires should be checked periodically for cracks and wear and should be replaced as necessary Initial adjustments should be made to suit your personal body structure needs and preference Thereafter follow these maintenance procedures All Wheelchairs Inspect Adjust Initially Q Ensure that the wheelchair rolls straight no excessive drag or pull to one side Q Ensure that the arms are secure but easy to release and adjustment levers engage properly Ensure that adjustable height arms operate and lock securely Ensure armrest pads sit flush against arm
57. nd note whether there is a source of EMI nearby Important Information 1 20 volts per meter V m is a generally achievable and useful immunity level against EMI as of May 1994 the higher the level the greater the protection 2 This device has been tested to a radiated immunity level of 20 volts per meter 3 The immunity level of the product is unknown Modification of any kind to the electronics of this wheelchair as manufactured by Invacare may adversely affect the EMI immunity levels Part No 1148076 15 Pronto M51 Base with SureStep SECTION 3 SAFETY HANDLING OF WHEELCHAIRS SECTION 3 SAFETY HANDLING OF WHEELCHAIRS Safety and Handling of the wheelchair requires the close attention of the wheelchair user as well as the assistant This manual points out the most common procedures and techniques involved in the safe operation and maintenance of the wheelchair It is important to practice and master these safe techniques until you are comfortable in maneuvering around the frequently encountered architectural barriers Use this information only as a basic guide The techniques that are discussed on the following pages have been used successfully by many Individual wheelchair users often develop skills to deal with daily living activities that may differ from those described in this manual Invacare recognizes and encourages each individual to try what works best for him her in overcoming architectural ob
58. nspect Adjust Periodically OU DU Ensure seat release latch is functional Replace if necessary Ensure wheelchair rolls straight no excessive drag or pull to one side Inspect charger AC power cord for damage Replace if necessary Ensure casters are free of debris Inspect electrical components for signs of corrosion Replace if corroded or damaged Check that all labels are present and legible Replace if necessary Troubleshooting Guide NOTE For additional troubleshooting information and explanation of error codes refer to the Electronics Manual supplied with each wheelchair Part No 1148076 23 Pronto M51 Base with SureStep SECTION 4 SAFETY INSPECTION TROUBLESHOOTING All Wheelchairs General Troubleshooting SYMPTOM Limited driving distance PROBABLE CAUSE Batteries not charged long enough Batteries weak wont hold charge SOLUTIONS Charge batteries overnight or ensure 8 hours of charge time between use Ensure correct setting on charger Replace Batteries Batteries not charging Batteries draw excessive current when charging Charger indicator shows low charge level immediately after charging Charger not working Battery connections loose No current at wall outlet Bad connection on charger charger cable plug or internal wiring problem Battery failure Batteries weak wont hold charge Electrical malfunction Charger malfunction Have charger re
59. nual supplied with wheelchair Wheelchair does not respond to commands Power indicator off even after recharging Poor battery terminal connection Electrical malfunction Pronto M51 Base with SureStep 24 Have terminals cleaned Contact Dealer Invacare for service Part No 1148076 SECTION 4 SAFETY INSPECTION TROUBLESHOOTING SPJ w PSS or SPJ w ACC Joysticks The joystick information gauge and the service indicator give indications of the type of fault or error detected by the control module When a fault is detected the wheelchair may stop and not drive The LEDs on the information gauge may flash in a particular pattern or the service indicator light will flash The number or type of flashes indicates the nature of the error If multiple errors are found only the first error encountered by the control module will be displayed Information Gauge Display Diagnostics DISPLAY DESCRIPTION DEFINITION COMMENTS Information Gauge Display All LEDs are off Power is off All LEDs are on Power is on Fewer than three LEDs on implies reduced battery charge Left RED LED is flashing Battery charge is low The batteries should be charged as soon as possi ble Left to Right chase Joystick is in The steady LEDs indicate alternating with steady programming inhibit and the current state of the display or charging mode battery charge All LEDs are flashing slowly Joy
60. o the joystick charger port at the same time Doing so will reduce the life of the batteries Read and carefully follow the manufacturer s instructions for each charger supplied or purchased If charging instructions are not supplied consult a qualified technician for proper procedures Ensure the pins of the extension cord plug are the same number size and shape as those on the charger DO NOT under any circumstances cut or remove the round grounding plug from the charger AC cable plug or the extension cord plug Pronto M51 Base with SureStep 12 Part No 1148076 SECTION GENERAL GUIDELINES Grounding Instructions DO NOT under any circumstances cut or remove the round grounding prong from any plug used with or for Invacare products Some devices are equipped with three prong grounding plugs for protection against possible shock hazards and fire Where a two prong wall receptacle is encountered it is the personal responsibility and obligation of the customer to contact a qualified electrician and have the two prong receptacle replaced with a properly grounded three prong wall receptacle in accordance with the National Electrical Code If you must use an extension cord use only a three wire extension cord having the same or higher electrical rating as the device being connected In addition Invacare has placed RED ORANGE warning tags on some equipment DO NOT remove these tags Rain Test Invacare has tested its powe
61. oes not recommend any wheelchair transportation systems Refer to Transport Ready Package on page 62 for more information about trans porting the wheelchair Part No 1148076 5 Pronto M51 Base with SureStep SPECIAL NOTES TRRO AND TRBKTS WARNINGS Only use the transport brackets included with TRRO and TRBKTS for the purposes described in this manual WARNING ALWAYS wear your seat positioning strap The seat positioning strap is a positioning belt only It is not designed for use as a safety device withstanding high stress loads such as auto or aircraft safety belts If signs of wear appear the belt MUST be replaced IMMEDIATELY Invacare products are specifically designed and manufactured for use in conjunction with Invacare accessories Accessories designed by other manufacturers have not been tested by Invacare and are not recommended for use with Invacare products POWERED SEATING SYSTEMS ONLY This seating system has been customer designed and will be assembled to the wheelchair base before delivery to the user The information contained in this manual is for maintaining and adjusting the seating system There are very few adjustments that can safely be made by the user If there is a procedure or adjustment that needs to be performed on the seating system that is not in this manual DO NOT perform that procedure Have the seating system serviced by a qualified technician The drive behavior initially exper
62. ok and loop straps Perform one of the following Lower the seat assembly to the up position Refer to Tilting the Seat Assembly Formula CG Only on page 41 Install the seat assembly from the wheelchair Refer to Removing Installing the Seat Assembly on page 43 4 Connect the joystick Refer to Disconnecting Connecting the Joysticks on page 40 5 Connect the powered seating system NOTE Batteries and seating system not Battery shown for clarity Shroud Hook and Loop Straps FIGURE 8 1 Removing Installing the Battery Shroud Pronto M51 Base with SureStep 48 Part No 1148076 SECTION 8 TOP SHROUD AND WHEELS Engaging Disengaging Motor Release Lever WARNING DO NOT engage or disengage the motor release lever until the On Off switch on the joystick is in the Off position CAUTION Ensure both motor release levers are fully engaged before driving the wheelchair NOTE For this procedure refer to FIGURE 8 2 NOTE The motor lock disengagement engagement allows freewheeling or joystick controlled operation Freewheeling allows an attendant to maneuver the wheelchair without power 1 Locate the motor release handles on the motors protruding through the top shroud on the rear of the wheelchair N Perform one of the following e To Disengage the Motor Release Levers Pull the motor lock lever towards the rear of the wheelchair freewheel position NOTE This allows the chair to f
63. or a dealer with a copy of the seller s invoice required for coverage under this warranty Invacare warrants all batteries to be free from defects in materials and workmanship for a period of six 6 months from the date of purchase from Invacare or a dealer with a copy of the seller s invoice required for coverage under this warranty Invacare warrants all remaining components excluding all upholstered materials padded materials tires and wheels to be free from defects in materials and workmanship for a period of one 1 year from the date of purchase from Invacare or a dealer with a copy of the seller s invoice required for coverage under this warranty If within such warranty periods any such product component shall be proven to be defective the product component shall be repaired or replaced at Invacare s option This warranty does not include any labor or shipping charges incurred in replacement part installation or repair of any such product Invacare s sole obligation and your exclusive remedy under this warranty shall be limited to such repair and or replacement For warranty service please contact the dealer from whom you purchased your Invacare product In the event you do not receive satisfactory warranty service please write directly to Invacare at the address on the bottom of the back cover Provide dealer s name address date of purchase indicate nature of the defect and if the product is serialized indicate the serial number
64. pelvic belt should be within the preferred zone of 45 to 75 side New degrees to the horizontal OR within the optional zone of 30 to 45 degrees to the Preferred Zone horizontal Optional Zone Steeper side view pelvic belt angles are especially important if the pelvic belt is intended to be used for postural support in addition to occupant restraint in a frontal crash Steeper angles will reduce the tendency for a vertical gap to develop between the user and the belt due to compliance of seat cushions and belt movement thereby reducing the tendency for the user to slip under the belt and for the belt to ride up on the soft abdomen during normal use Steeper belt angles also reduce the tendency for upper torso belts to pull the pelvic belt onto the abdomen during frontal impact loading NOTE For this procedure refer to FIGURE 10 4 1 The pelvic belt should be worn low across the front of the pelvis 2 Position the upper torso belt s over the shoulders 3 The belt s should not be held away from the body by wheelchair components or parts including but not limited to wheelchair armrests or wheels Refer to FIGURE 10 4 for proper and improper positioning of the belts 4 Ensure the belt s are not twisted 5 Adjust belts as firmly as possible being mindful of user comfort DO POSITION BELT INSIDE OF DO NOT POSITION BELT OUTSIDE OF ARMRESTS WHEELS ETC ARMRESTS WHEELS ETC FIGURE 10 4 Positioning Belts P
65. placed Contact Dealer Invacare Check all connections Secure connections Switch to another wall outlet Replace charger or internal repairs may be required Contact Dealer Invacare Have batteries checked for shorted cell Replace if necessary Replace Batteries Contact Dealer Invacare Replace charger Contact Dealer Invacare Battery indicator flashes the charge level is low immediately after recharging Weak Batteries Charger malfunction Electrical malfunction Replace batteries Replace charger Contact Dealer Invacare Contact Dealer Invacare Wheelchair will not drive Motor release levers are disengaged Batteries require charging Charger plugged in Circuit breaker tripped Engage motor release levers Charge batteries Make sure the setting on the charger is correct Unplug charger from wall outlet before operating the wheelchair Reset circuit breaker If breaker trips again it may indicate need for internal repair Contact Dealer Invacare Motor chatters or runs irregularly Electrical malfunction Contact Dealer Invacare Only one drive wheel turns Electrical malfunction One motor lock is disengaged Contact Dealer Invacare for service Engage motor lock Joystick erratic or does not respond as desired Electrical malfunction Controller programmed improperly Contact Dealer Invacare for service Reprogram controller Refer to electronics ma
66. r damage may result Before performing any maintenance adjustment or service verify that On Off switch on the joystick is in the Off position Replacing the Flat Free Tires on the Wheel Rim WARNING DO NOT attempt to replace flat free tires This procedure MUST be performed by a qualified technician NOTE During initial use of the wheelchair the user may experience flat spots on the wheels Flat spots will vanish with continued use of the wheelchair Removing Installing the Battery Shroud NOTE For this procedure refer to FIGURE 8 1 on page 48 Removing 1 Disconnect the joystick Refer to Disconnecting Connecting the Joysticks on page 40 2 Perform one of the following e Tilt the seat assembly to the up position Refer to Tilting the Seat Assembly Formula CG Only on page 41 Remove the seat assembly from the wheelchair Refer to Removing Installing the Seat Assembly on page 43 3 If Installed disconnect the powered seating system B Lifting up to release the hook and loop straps remove the battery shroud from the base frame Part No 1148076 47 Pronto M51 Base with SureStep SECTION 8 TOP SHROUD AND WHEELS Installing 1 Ensure the seat is tilted back to the up position or removed Refer to Tilting the Seat Assembly Formula CG Only on page 41 or Refer to Removing Installing the Seat Assembly on page 43 Place the battery shroud on the base frame and push downward to engage the ho
67. r wheelchairs in accordance with ISO 7176 Rain Test This provides the end user or his her assistant sufficient time to remove his her power wheelchair from a rain storm and retain wheelchair operation DO NOT leave power wheelchair in a rain storm of any kind DO NOT use power wheelchair in a shower DO NOT store power wheelchair in a damp area for an extended period of time Direct exposure to excessive rain or dampness may cause the chair to malfunction electrically and mechanically may cause the chair to prematurely rust or may damage the upholstery Check to ensure that the RED and GREY battery terminal caps are secured in place joystick boot is not torn or cracked where water can enter and that all electrical connections are secure at all times DO NOT use the wheelchair if the joystick boot is torn or cracked If the joystick boot becomes torn or cracked replace immediately Weight Training Invacare does not recommend the use of its wheelchairs as a weight training apparatus Invacare wheelchairs have not been designed or tested as a seat for any kind of weight training If occupant uses said wheelchair as a weight training apparatus Invacare shall not be liable for bodily injury and the warranty is void Weight Limitation The wheelchair has a weight limitation of 300 Ibs Part No 1148076 13 Pronto M51 Base with SureStep SECTION 2 EMI INFORMATION SECTION 2 EMI INFORMATION WARNING CAUTION IT IS VERY IMPOR
68. re that the casters are oriented as shown in FIGURE 3 2 Qs OL jg ee Using the rear and front forks as hand hold supports transfer the wheelchair base to desired location Refer to FIGURE 3 2 7 Using non removable nondetachable parts transfer the seat and any accessories to desired location 8 Reinstall any accessories that were removed in STEP 3 9 Reinstall the seat Refer to Tilting the Seat Assembly Formula CG Only on page 41 Front Fork Front Edge Rear Frame WARNING ESCALATORS DO NOT use an escalator to move a wheelchair between floors Serious bodily injury may occur Part No 1148076 19 Pronto M51 Base with SureStep SECTION 3 SAFETY HANDLING OF WHEELCHAIRS Transferring To and From Other Seats WARNING ALWAYS turn the wheelchair power Off and engage the Motor Release Levers to prevent the wheels from moving before attempting to transfer in or out of the wheelchair Also make sure every precaution is taken to reduce the gap distance by aligning both the front and rear casters parallel with the object you are transferring onto CAUTION When transferring position yourself as far back as possible in the seat This will pre vent broken screws damaged upholstery and the possibility of the wheelchair tip ping forward NOTE This activity may be performed independently provided you have adequate mobility and upper body strength NOTE For this
69. reewheel for pushing if necessary NOTE It may be necessary to rock the wheels slightly until the motor release lever disengages To Engage the Motor Release Levers Push the motor lock handles towards the front of the wheelchair drive position NOTE This allows the motors to drive the wheels NOTE It may be necessary to rock the wheels slightly until the motor release lever engages Right Motor Release Lever Shown Disengaged Engaged FIGURE 8 2 Engaging Disengaging Motor Release Lever Part 1148076 49 Pronto M51 Base with SureStep SECTION 8 TOP SHROUD AND WHEELS Replacing Front Rear Caster Assemblies NOTE For this procedure refer to FIGURE 8 3 NOTE Front and rear caster assemblies are replaced in the same manner NOTE When replacing the front rear caster assemblies it is necessary to brace the caster assemblies to prevent the wheel from spinning Locknut 1 Remove the mounting screw two washers and locknut that secures the caster to the fork 2 Remove the caster and discard 3 Secure new caster to fork with existing mounting screw two washers and FIGURE 8 3 Replacing Front Rear Caster locknut FIGURE 8 3 Securely tighten Assemblies Adjusting Forks NOTE For this procedure refer to FIGURE 8 4 1 Remove the dust cover 2 To properly tighten caster journal system and guard against flutter perform the following check A Tip back the wheelchair B Pivo
70. roduct While considered typical they are derived based on certain ideal conditions Variances in battery condition user weight usage pattern or overall terrain conditions will result in actual values for range that differ from these stated values Users should become accustomed to how their unique conditions impact their individual results Users should become familiar with the battery discharge indicator on the joystick to determine the range of their wheelchair Refer to Battery Charger Operation on page 59 for more information about the battery discharge indicator Part No 1148076 7 Pronto M51 Base with SureStep LABEL LOCATION Pinch Point 1079203 Pronto M51 Base with SureStep LABEL LOCATION The POSITIVE RED Battery Cable MUST connect to the POSITIVE Battery Terminal s Post s The NEGATIVE BLACK Battery Cable MUST connect to the NEGATIVE Battery Terminal s Post s DO NOT allow Battery Cable s to contact the opposite Battery Terminal s Post s Install protective caps on POSITIVE and NEGATIVE battery terminals Replace cable s immediately if cable s insulation becomes damaged Failure to observe these warnings may result in an electrical short with serious personal injury and or damage to the electrical system See Owner s Manual DO NOT remove fuse or mounting hardware from POSITIVE RED battery cable mounting screw DO NOT REMOVE THIS LABEL Washer BAIT FUSE L Bracket RED
71. ronto M51 Base with SureStep 68 Part No 1148076 5 5 Part No 1148076 69 Pronto M51 Base with SureStep 5 5 Pronto M51 Base with SureStep 70 Part No 1148076 5 5 Part No 1148076 71 Pronto M51 Base with SureStep LIMITED WARRANTY PLEASE NOTE THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW APPLICABLE TO PRODUCTS MANUFACTURED AFTER JULY 4 1975 This warranty is extended only to the original purchaser who purchases this product when new and unused from Invacare or a dealer This warranty is not extended to any other person or entity and is not transferable or assignable to any subsequent purchaser or owner Coverage under this warranty will end upon any such subsequent sale or other transfer of title to any other person This warranty gives you specific legal rights and you may also have other legal rights which vary from state to state Invacare warrants the base frame to be free from defects in materials and workmanship for a period of five 5 years from the date of purchase from Invacare or a dealer with a copy of the seller s invoice required for coverage under this warranty Invacare warrants all electronics and electrical components excluding batteries 2 pole and 4 pole motors powered seating actuators and gearboxes to be free from defects in materials and workmanship for a period of one 1 year from the date of purchase from Invacare
72. ry Shroud BLACK Battery Connectors RED Battery Connectors BLACK Controller Rear Battery Connector Plug into Controller Joystick Cable Front Battery Rear of Wheelchair Front of Wheelchair Wheelchair Base Frame Pronto M51 Base with 54 Part No 1148076 SECTION 9 BATTERIES Connecting Disconnecting Battery Cables Connecting Battery Cables WARNING NEVER allow any of your tools and or battery cables to contact both battery terminals at the same time An electrical short may occur and serious personal injury or damage may occur Connect same color connectors to each other RED to RED BLACK to BLACK DO NOT remove fuse or mounting hardware from POSITIVE battery cable mounting screw To replace the fuse obtain and replace battery harness with fuse The POSITIVE battery cable MUST connect to the POSITIVE battery terminal otherwise serious damage will occur to the electrical system The use of rubber gloves is recommended when working with batteries Battery terminal configuration as shown in Detail A of FIGURE 9 3 MUST be used Batteries that have the terminal configuration reversed MUST NOT be used otherwise serious injury or damage may occur Install protective caps on POSITIVE and NEGATIVE terminals All battery terminal covers two on the front battery and two on the rear battery MUST be installed prior to use CAUTION When connecting the batt
73. se the speed in 20 increments The larger bars in the speedometer will light e Adjust Speed in Smaller Increments VSP Mode Perform the following steps i Press and hold both the tortoise button and hare button until the joystick beeps ii Perform one of the following e Press the tortoise button or hare button to decrease increase the speed in 2076 increments The larger bars in the speedometer will light e Press and hold the tortoise button s or hare button ey to decrease increase the speed in smaller increments The smaller bars in the speedometer will light Joystick The joystick has proportional drive control meaning that the further the joystick is pushed from the upright neutral position the faster the wheelchair or seat moves Your top speed however is limited by the programmed settings To slow the wheelchair to a stop simply release the joystick The wheelchair has automatic speed and direction compensation to minimize corrections Charger Programming Input The charger programming input is located at the front of the joystick housing This provides easy access for charging the wheelchair batteries This port also serves as the Remote Programmer Communication connection Driving is prevented while the system is charging Service Indicator The AMBER service indicator will light when an error or fault occurs Refer to Service Indicator Light Diagnostics on page 30 for a listin
74. stacles that they may encounter however all WARNINGS and CAUTIONS given in this manual MUST be followed Techniques in this manual are a starting point for the new wheelchair user and assistant with safety as the most important consideration for all Stability and Balance WARNING ALWAYS wear your seat positioning strap The seat positioning strap is a positioning belt only It is not designed for use as a safety device withstanding high stress loads such as auto or aircraft safety belts If signs of wear appear belt MUST be replaced immediately Be aware that carrying heavy objects on your lap while occupying the wheelchair may adversely affect the stability of the wheelchair resulting in serious bodily injury to the user damage to the wheelchair and surrounding property This wheelchair has been designed to accommodate one individual If more than one individual occupies the wheelchair this may adversely affect the stability of the wheelchair resulting in serious bodily injury to the user and passenger and damage to the wheelchair and surrounding property To assure stability and proper operation of your wheelchair you must at all times maintain proper balance Your wheelchair has been designed to remain upright and stable during normal daily activities as long as you do not move beyond the center of gravity DO NOT lean forward out of the wheelchair any further than the length of the armrests Pronto M51 Base with
75. stick has detected Out Release the joystick back of Neutral at Power Up to Neutral mode Part No 1148076 25 Pronto M51 Base with SureStep SECTION 4 SAFETY INSPECTION TROUBLESHOOTING Service Indicator Light Diagnostics NUMBER OF FLASHES ERROR CODE DESCRIPTION POSSIBLE SOLUTION User Fault Release joystick to neutral and try again Battery Fault Charge the batteries Refer to Charging Batteries on page 62 Check that battery cables are connected properly If necessary replace batteries Refer to Replacing Batteries on page 55 Left Motor Fault Contact Invacare Dealer for service Right Motor Fault Contact Invacare Dealer for service Left Park Brake Fault Contact Invacare Dealer for service Right Park Brake Fault Remote Fault Contact Invacare Dealer for service Check to make sure joystick is connected properly Contact Invacare Dealer for service Controller Fault Contact Invacare Dealer for service Communications Fault Contact Invacare Dealer for service General Fault Contact Invacare Dealer for service Remote Incompatible or incorrect for service PSR PSF Joysticks or Displays SYMPTOM A SPM L Park Brake Fault or SPM R Park Brake Fault displays and wheelchair does not drive PROBABLE CAUSE Motor lock levers disengaged Error code 9 or E10 Wrong type of remote connected Contact
76. stions about using this wheelchair for seating in a motor vehicle When feasible wheelchair occupants should transfer into the vehicle seat and use the OEM Original Equipment Manufacturer vehicle installed restraint system This wheelchair has been dynamically tested in a forward facing mode with the specified crash test dummy restrained by BOTH pelvic and upper torso belt s shoulder belts and that BOTH pelvic and upper torso belt s should be used to reduce the possibility of head and chest impacts with vehicle components Use ONLY Wheelchair Tie down and Occupant Restraint Systems WTORS which meet the requirements of the SAE Society of Automotive Engineers J2249 Recommended Practice during travel in a motor vehicle This wheelchair has been tested for seating in a motor vehicle with the factory installed seating system ONLY This wheelchair MUST be in a forward facing position during travel in a motor vehicle This wheelchair is equipped and has been dynamically tested to rely on WHEELCHAIR ANCHORED pelvic belts If desired VEHICLE ANCHORED pelvic belts may be used IT IS STRONGLY RECOMMENDED THAT BOTH PELVIC AND UPPER TORSO BELT S BE USED TO REDUCE THE RISK OF INJURY To reduce the potential of injury to vehicle occupants wheelchair mounted accessories including but not limited to IV poles trays respiratory equipment backpacks and other personal items should be removed and secured separately Postural supports positionin
77. switch functions operate through mono port 1 An optional y cable allows a second programmable function through mono port 2 Remote Stop Switch The remote stop switch is used to stop the wheelchair Remote Mode Reset Switch The remote mode reset switch functions the same way as the mode switch Refer to Mode Switch on page 38 Part No 1148076 37 Pronto M51 Base with SureStep SECTION 5 WHEELCHAIR OPERATION Remote On Off Switch The remote On Off switch input is located at the rear of the joystick on the right side and allows the power switch to be operated by an ability switch normally open momentary switch with mono plug To use the remote On Off feature the Drive Select On Off switch must be in the On position Each activation of the ability switch will alternately turn the joystick On or Off Mode Switch NOTE For this procedure refer to FIGURE 5 4 on page 34 The mode switch is used to select the operating mode for the wheelchair The mode switch is located on the joystick A mode switch is needed whenever any of the following operating modes are programmed e Environmental Controls ECU 1 ECU 2 ECU 3 ECU 4 e 3 Speed Mode in Digital 3 Speed Slow Medium Full e Latched Modes Sleep Mode RIM Mode e Remote Drive Selection Mode e Tilt Recline Mode e Information Center Display Selection does not require Reset activation at power up If any of the above modes are selected the control will
78. t both forks and casters to top of their arc simultaneously C Let casters drop to bottom of arc Tabs wheels should swing once to one Suspe sud side then immediately rest in a straight downward position lobe D Adjust locknut according to Wachee freedom of caster swing Side tas Shroud 3 Test wheelchair for maneuverability Caster 4 Readjust locknut if necessary and Headtube repeat STEPS 2 3 until correct 9 5 Snap dust cover into the caster Base Frame Washer headtube ensuring that the tabs are under the plastic side shrouds Fork NOTE Components exploded for clarity There is no need to remove the fork from the base FIGURE 8 4 Adjusting Forks frame Pronto M51 Base with SureStep 50 Part No 1148076 SECTION 9 BATTERIES SECTION 9 BATTERIES Warnings For Handling and Replacing Batteries WARNING After any adjustments repair or service and before use make sure that all attaching hardware is tightened securely otherwise injury or damage may result Make sure power to the wheelchair is Off before performing this section The use of rubber gloves is recommended when working with batteries Invacare strongly recommends that battery installation and battery replacement ALWAYS be done by a qualified technician UI batteries weigh 24 pounds each Use proper lifting techniques lift with your legs to avoid injury Use U I batteries only Failure to use the correct battery s
79. t the type of operation or performance which best suits a particular control need or situation The DRIVE 1 program uses performance values which are independent of those used for the DRIVE 2 or 3 or 4 program As an example an operator may have a control need for spasticity in the morning and a very different need in the afternoon DRIVE 1 can be programmed for higher speeds and quicker response while DRIVE 2 can be programmed for slower speeds and less responsiveness or vise versa The other two drive programs could be indoor and outdoor versions of DRIVE 1 and DRIVE 2 Selecting the Drive Mode 1 Move the toggle up and release DRIVE 1 51 will appear on LCD Move the toggle up and release again DRIVE 2 03 will appear on LCD Move the toggle up and release again DRIVE 3 53 will appear on LCD Move the toggle up and release again DRIVE 4 p4 will appear on LCD g F N Move the toggle up and release one more time to select DRIVE 1 1 Part No 1148076 33 Pronto M51 Base with SureStep SECTION 5 WHEELCHAIR OPERATION Memory Card Slot Charger Programming Input Front of Joystick LCD Display Mode Switch W Drive Select Toggle Switch Speed Control Knob AB LUI Programmable ono Port 1 2 or External Mode Remote On Off Input Switch To Controller FIGURE 5 4 MPJ Joystick Switches and Indicators Joystick Speed
80. ted occupants restrained by BOTH pelvic and upper torso belt s and ONLY by a pelvic belt are shown in the diagrams and described below Frontal Clear Zones FCZ need to be LARGER when upper torso belt s are NOT used The rear clear zone of 6 inches is measured from the rearmost point on an occupant s head The frontal clear zone is measured from the frontmost point on an occupant s head and is 26 inches with pelvic and upper torso belt s and 37 inches with ONLY a pelvic belt The frontal clear zone may not be achievable for wheelchair seated drivers The estimated seated height HHT from the ground or floor to the top of the wheelchair seated occupant s head ranges from approximately 47 inches for a small adult female to about 61 inches for a tall adult male Side View Frontal Clear l6 in pe E RN Loc buone een cce Frontal Clear Zone Pronto M51 Base with SureStep Part No 1148076 SECTION 10 TRANSPORT READY PACKAGE Securement Points Tie Down Bracket hidden from view Tie Down Brackets Bracket FIGURE 10 1 Securement Points Securing the Wheelchair This wheelchair is to be used only with Wheelchair Tie down and Occupant Restraint Systems WTORS that have been installed in accordance with the manufacturer s instructions and SAE J2249 NOTE A copy of SAE J2249 Wheelchair Tie down and Occupant Restraint Systems WTORS for use in Motor Vehicles can b
81. th SureStep 44 Part No 1148076 SECTION 7 FOOTBOARD ASSEMBLY Installing WARNING Make sure the detent balls of the quick release pin are fully released beyond the outer edge of the tube before operating the wheelchair Otherwise injury and or damage may result Keep detent balls clean 1 Position the footboard assembly onto the wheelchair frame so that the mounting hole in the wheelchair frame aligns with the desired mounting hole in the footboard assembly 2 Install the quick release pin by depressing the button while sliding the pin in Ensure that the detent balls of the quick release pin are fully released beyond the outer edge of the tube Detail A of FIGURE 7 1 DETAIL A BOTTOM VIEW OF FOOTBOARD Three Depth Adjustment Holes Quick Release Pin ME TEN Footboard Assembly im Mounting Hole Quick Detent Detent Balls Release Pin Ball Outer Edge of Tube FIGURE 7 1 Removing Installing the Footboard Assembly Adjusting the Footboard Assembly Angle NOTE For this procedure refer to FIGURE 7 2 on page 46 1 Loosen the jam nut and set screw located underneath on the backside of the footplate 2 Adjust the set screw in or out to obtain the desired footboard assembly angle 3 Thread the jam nut and washer inward until it is flush with the footboard bracket 4 Securely tighten the jam nut and washer to secure the mounting screw in place Part No 1
82. tructions Part No 1148076 35 Pronto M51 Base with SureStep SECTION 5 WHEELCHAIR OPERATION ITEM DESCRIPTION STATUS INDICATOR The status indicator will show a Warning exclamation point inside a triangle indicator when the chair has a condition that requires attention The status indicator will show a STOP sign when a serious condition exists The chair will not be allowed to operate The status indicator shows an Attendant Icon if the attendant s override switch is active The dotted box shows the area that contains the available modes in the cur rently selected drive The modes are programmed for each drive and are based upon the configuration of the chair These modes are highlighted when the Mode is active The operator changes modes by pressing the Mode Select Switch The available modes are as follows Drive Mode I through 4 Automatic Positioning Actuator Control Switch Mode 4 switch 4 switch 2 levels etc ECU Output Activated I through 4 RIM Mode Activated Drive Select Mode Activated No Driving Drive Profile Name Available Modes in Drive Indicator Battery Gauge Display this Drive Must be Programmed CH UTDOOR Nr Eu Icon appears when a 1 joystick command a 4 drive the wheelchair TILT WARNING E Status Info Message Area ECU Stat
83. unting tube into the mounting bracket Part No 1148076 39 Pronto M51 Base with SureStep SECTION 5 WHEELCHAIR OPERATION Disconnecting Connecting the Joysticks NOTE For this procedure refer to FIGURE 5 10 on page 40 NOTE The joystick connector is located at the rear of the seat frame SPJ Joysticks Disconnecting 1 Hold the light GREY collar portion of the joystick connector with one hand and the controller connector on the wheelchair in the other and disconnect them by pulling them apart Connecting WARNING The joystick connector and controller connector fit together in one way only DO NOT force them together 1 Hold the light GREY collar portion of the joystick connector with one hand Light Grey Collar and the controller connector on the wheelchair in the other and align them Joystick Connector Controller Connector 2 Lightly push to engage the joystick connector and the controller connector FIGURE 5 10 Disconnecting Connecting the Joysticks SP Joysticks MPJ Joysticks NOTE For this procedure refer to FIGURE 5 11 Disconnecting 1 Pull the latch away from the joystick connector 2 Disconnect the joystick connector from Joystick the remaining connectors Connector Connecting TEM 1 Ensure the latch is pulled away from the joystick connector 2 Connect the joystick connector to the Other Connectors other connectors 3 Push the latch in to se
84. us Indicator FIGURE 5 6 LCD Display Screens Main Screen Driving Screen NOTE For this procedure refer to OUTOOOR FIGURE 5 7 p This screen is shown when the operator issues a drive command and the Drive Icon on the main screen was highlighted NOTE The Drive s name warning info message status icon and battery indicator are displayed on this screen FIGURE 5 7 LCD Display Screens Driving Screen Pronto M51 Base with SureStep 36 Part No 1148076 SECTION 5 WHEELCHAIR OPERATION Connected Devices Screen NOTE For this procedure refer to FIGURE 5 8 This screen is displayed if the Mode Select switch is held active for about 10 seconds This screen shows an icon that represents any additional devices that are connected to the chair ICON DESCRIPTION 4 Switch Attendant Control CONNECTED DEVICES RIM Control Proportional Attendant Control RELEASE MODE SWITCH Compact Joystick Sip and Puff Control ASL Digital Control ASL Analog Control Shark Power Module Actuator FIGURE 5 8 LCD Display Screens Connected Devices Screen Programmable Mono Port 1 2 or External Mode Switch The programmable mono port or external mode switch input is located at the rear of the joystick on the left side The programmable mono port input offers the choice of three options e Remote drive select Remote stop mode reset input e Single actuator input The single
85. y clean the baking soda from the battery tray or battery being sure to avoid contact with skin and eyes Determine source of contamination NEVER install reinstall a battery with a cracked or otherwise damaged case Part No 1148076 51 Pronto M51 Base with SureStep SECTION 9 BATTERIES Using the Proper Batteries NOTE For this procedure refer to FIGURE 9 1 1 2 Place battery ground flat surface Visually draw a horizontal and vertical centerline through the middle of battery FIGURE 9 1 3 Position the battery so that the terminals are above the horizontal centerline 4 Visually inspect the battery to ensure the correct position of the POSITIVE and NEGATIVE terminals FIGURE 9 1 WARNING Batteries with terminal configuration as shown below MUST be used Batteries that have the reverse terminal configuration MUST NOT be used otherwise injury and damage may occur Use This Configuration DO NOT Use NEGATIVE POSITIVE Battery Terminal Battery Terminal NEGATIVE Battery Terminal UI Battery POSITIVE Battery Terminal UI Battery FIGURE 9 1 Using the Proper Batteries Pronto M51 Base with SureStep 52 Part No 1148076 SECTION 9 BATTERIES Removing Installing Batteries from into Battery Tray WARNING ALWAYS use the battery handle when lifting the battery It is the most convenient method and assures that the battery