1. Enable Set a status message to be transmitted in the Send Status Number item E Sounding a Horn The automatic honking function can be used when a horn is connected to the transceiver through the optional ACC cable OPC 1939 D Sub 15 pin or OPC 2078 D Sub 25 pin When a status message is received the transceiver sounds the vehicle s horn for the specified time period to inform you that a status message has being received This function is convenient when the operator is away from the transceiver Ask your dealer or system operator or refer to the IC F5120D F6120D series service manual for connection and setting details E Connecting a Printer When the printer is connected to the transceiver through the OPC 2078 the received SDM content and the called station ID can be printed out Ask your dealer or system operator for connection details E Using Voice Encryption The encryption function enables voice encrypting which pro vides private digital communication between stations D Push Encryption to turn ON the encryption function e QD appears 2 Push Encryption again to turn OFF the encryption func tion e QD disappears IDAS OPERATION 3 Count on us Icom Inc A 6903 2EX 0a 1 1 32 Kamiminami Hirano ku Osaka 547 0003 Japan 2011 Icom Inc
2. 0 enanar aranana nane 15 E Sounding a HON EE 15 M Connecting a Printer rrrnrnrnnnnrvnnrnnnnnnnevnvennnnnnernennnnen 16 WE Using Voice Encryption uunessmmmmidenennnerdrentenn 16 I PREPARATION E Programmable function keys The following functions can be assigned to the UP DOWN PO P1 P2 and P3 programmable function keys Consult your Icom dealer or system operator for details con cerning your transceivers preprogramming For only IDAS operation DIGITAL BUTTON KEY Push Digital Button to enter the application selection mode Hold down for 1 second to toggle the call type between Individual and Talkgroup and then automatically enter the application selection mode e Push the CH Up or CH Down key to select the VOICE CALLALRT STATUS MSG or CALL LOG application While in the application selection mode push to enter the Individual or Talkgroup ID selection mode e If STATUS or MSG is selected as the application the message selection mode appears Push the CH Up or CH Down key to select the desired message then push Digital Button again to enter the Individual or Talkgroup ID selection mode pp 12 13 While in the application selection mode hold down Digital Button for 1 second to return to the normal operating mode STATUS UP DOWN KEYS When a Short Data Message SDM is displayed push to cancel the automatic scroll and manually scroll
3. IDAS OPERATION 3 IMPORTANT Setting an individual emergency channel is ecommended for dependable emergency call operation ga NN 4 r OTE When the Digital Request Ack function is activated the transceiver transmits an emergency call with a request to send back an acknowledgment TLL 14 15 3 IDAS OPERATION E Transmitting Position data When a GPS receiver is connected to the transceiver the position longitude and latitude data can be automatically transmitted e When the GPS request status message is received After sending a voice message Set the Send with Voice Call item to Enable e After sending a status message Set the Send with Status Call item to Enable e After sending a message Set the Send with SDM Call item to Enable e After sending a Call Alert Set the Send with Call Alert item to Enable e After sending an Emergency call Set the Send with Emergency item to Enable Ask your dealer or system operator for connection details E Transmitting Status messages A status message can be automatically transmitted A status message is transmitted e When the transceiver is turned ON or turned OFF Set a status message to be transmitted in Power ON Status or Power OFF Status item respectively Set the target station ID in Power Status ID e After sending a voice message Set the Send with Voice Call item to
4. 6 Release PTT e After receiving an acknowledgement from the targeted station CA OK is displayed e If the targeted station does not receive the signal or send back an acknowledgement CA FAIL is displayed D After a specified time period has passed the transceiver will return to receive Transmitting a Status Message The transceiver has the ability to send a preprogrammed sta tus message There are up to 100 status messages that can be sent D Push Digital Button to enter the application selection mode e VOICE appears e To change to the desired call type hold down Digital Button for 1 second while in standby After changing the transceiver auto matically enters the application selection mode 2 Push CH Up or CH Down to select STATUS 3 Push Digital Button again to enter the status message selection mode e A preprogrammed status message is displayed 4 Push CH Up or CH Down to select the desired mes sage Preprogrammed status message is displayed IDAS OPERATION 3 5 Push Digital Button again to enter the Individual or Talk group ID selection mode e The preprogrammed ID name is displayed e When an ID name is not programmed the ID code is displayed e The primary ID can be preset to display first 6 Push CH Up or CH Down to select the desired ID name or ID code Individual or Talkgroup ID name is displayed 7 Push PTT to transmit the st
5. COM pid Limited functions only E an a ud a ICOM DIGITAL ADVANCED SYSTEM Limited functions only OPERATING GUIDE FOR IC F5120D F6120D SERIES MDC 1200 SYSTEM IDAS OPERATION Icom Inc IMPORTANT Thank you for purchasing this Icom transceiver The MDC 1200 system and IDAS Icom Digital Advanced System functions are built into your IC F5120D F6120D se ries transceiver READ ALL INSTRUCTIONS carefully and completely before using the transceiver SAVE THIS OPERATING GUIDE This operating guide contains important operating instructions for e IC F5121D IC F5122D IC F5123D and IC F5128D VHF MOBILE TRANSCEIVERS e IC F6121D IC F6122D IC F6123D and IC F6128D UHF MOBILE TRANSCEIVERS Y INFORMATION The 10 keypad of the optional HM 152T Z DTMF microphone has only DIMF code transmitting ca Y pability Therefore IDs and messages cannot be input Z using the microphone Icom Icom Inc and the Icom logo are registered trademarks of Icom Incor porated Japan in Japan the United States the United Kingdom Germany France Spain Russia and or other countries IDAS and the IDAS logo are trademarks of Icom Incorporated Japan All other products or brands are registered trademarks or trademarks of their respective holders VOICE CODING TECHNOLOGY The AMBE 2 voice coding Technology embodied in this product is protected by intellectual property rights including patent rights copyrights and trade sec
6. display the call log informa tion When log information is displayed ID name When there is no log information Val N T INE 4 Push CH Up or CH Down to select the desired call 5 Hold down PTT to send a voice call voice call can be made with the logged station 3 IDAS OPERATION E Receiving a call continued Talk Back function The talk back function allows you to select the same call mode Analog or Digital and or call type Individual or Talk group as the received call When the talk back timer is set to 0 seconds this function is not activated Ask your dealer for setting details If this function is cancelled by pushing Digital Button or any other keys or after the talk back timer period has passed the transceiver automatically returns to the default call mode and type If the received call is a digital signal the talk back function is activated only for Voice Call Call Alert Status Message and Message Depending on the preprogramming the talk back function may be activated for only Voice Call When the channel type is Mixed Analog After receiving a digital signal you can select the digital call mode by pushing PTT before or during the talk back timer period When the channel type is Mixed Digital After receiving an analog signal that can release the mute you can select the analog call mode by pushing PTT before or during the talk back tim
7. or Status Down to manually scroll the mes sage W A Wn 2 To clear the ID and message display push PTT turn power OFF or change the channel IDAS OPERATION 3 Receiving a Stun Kill or Revive If an Individual call with a Stun or Kill command is received the transceiver will display SORRY and you can not receive or transmit RAN code matching may not be necessary de pending on the preprogramming Depending on the received Stun command setting Revive signals can always be received When a Stun command is received e The transceiver cannot be operated until an Individual call a Re vive command is received or you enter a password RAN code matching may not be necessary depending on the preprogram ming w When a Kill command is received e The transceiver cannot be operated until data cloning is per formed Ask your dealer for details NOTE Depending on the preprogramming the transceiver can ignore the Stun Revive and Kill commands that are from a non specified station MA 3 IDAS OPERATION E Receiving a call continued Receiving a Remote Monitor Radio Check or Status Polling Call If an Individual call with a Remote monitor Radio Check or Status polling command is received the transceiver will au tomatically transmit RAN code matching may not be neces sary depending on the preprogramming When a Remote monitor command is received e The microphone audi
8. the mes sage When an SDM that contains more than 8 characters is dis played push to manually scroll the message E MDC 1200 system operation The MDC 1200 signaling system enhances your transceiv ers Capabilities It allows PTTID Emergency signaling and receiving a Radio Check Also the dispatcher can stun and revive transceivers on the system An additional feature of the MDC 1200 system in Icom trans ceivers is called aliasing Each transceiver on the system has a unique ID number Aliasing allows substituting an alphanu meric name for the ID number When transmitting you can use this alias to select a transceiver to call When a call is received the alias of the calling station is displayed instead of the ID When PTT is pushed or released the transceiver transmits your station ID Y NOTE During MDC 1200 system operation IDAS opera 7 tion capability is disabled MDC 1200 OPERATION 2 E Receiving a call Receiving an Emergency Call 1 When an emergency call is received e Beeps sound e The calling station ID or alias and EMG EMG are alternately displayed N Val 11 104 Je jih N Val END EINA Ludt Eli pl Q To stop the beep and display indication turn OFF the power change the channel or push PTT Receiving a Stun and Revive The dispatcher can send MDC 1200 system signals that will stun or revive your transceiver If a Stun command that matches your station ID is receiv
9. atus message e STAT TK is displayed Release PTT e STAT OK is displayed after receiving an acknowledgement from the base station e STA FAIL is displayed if there is no acknowledgment from the base station 9 After a specified time period has passed the transceiver will return to standby 12 13 3 IDAS OPERATION E Transmitting a call continued Transmitting a Message The transceiver has the ability to send a preprogrammed message There are 10 messages that can be sent D Push Digital Button to enter the application selection mode e VOICE appears e To change to the desired call type hold down Digital Button for 1 second while in standby After changing the transceiver auto matically enters the application selection mode 2 Push CH Up or CH Down to select MSG 3 Push Digital Button again to enter the message selection mode e The preprogrammed message is displayed 4 Push CH Up or CH Down to select the desired message Preprogrammed message is displayed 5 Push Digital Button again to enter the Individual or Talk group ID selection mode e The preprogrammed ID name is displayed e When an ID name is not programmed the ID code is displayed e The primarily ID can be preset to display first 6 Push CH Up or CH Down to select the desired ID name or ID code Individual or Talkgroup ID name is displayed 7 Push PTT to trans
10. ed the transceiver will dis play SORRY default and you cannot receive or transmit When a Revive command that matches your station ID is received normal operation is restored and SORRY disap pears Except Revive command signals 2 MDC 1200 OPERATION E Transmitting a call PTTID Calls The transceiver can send an MDC 1200 system signal that includes PTTID when PTT is pushed begin transmitting and released stop transmitting If a PTTID call is received the transceiver will display the calling station s ID or alias and sound a beep Depending on the preprogramming Transmitting an Emergency Call When Emergency described in the instruction manual is held down for a specified time period the emergency signal is once or repeatedly transmitted on the specified emergency channel When no emergency channel is specified the call is transmitted on the operating channel The repeat emergency signal is automatically transmitted until you turn OFF the power Depending on the preprogramming receiving an acknowledgement may cancel the transmission If you want to cancel the Emergency function hold down Emergency for the preprogrammed time period again before transmitting the call If your transceiver is programmed for Silent operation you can transmit emergency calls without the beep sounding and the LCD display changing Z IMPORTANT Setting an individual emergency channel is Z recommend
11. ed for dependable emergency call operation Depending on the preprogramming the following functions can be automatically activated Ask your dealer for details NOTES e Auto TX function After an emergency call transmission audio from the microphone is automatically transmitted for a specified time period e The HM 148G or HM 152 HAND MICROPHONE is required e Auto RX function After an emergency call transmission the transceiver stands by in the audible mode for a specified time period E IDAS operation The IC F5120D and IC F6120D series use the Icom Digital Advanced System IDAS that meets the 6 25 kHz emission mask requirements for narrow banding IDAS increases ef ficiency of channel allocation and use of the RF spectrum 7 NOTE During IDAS operation MDC 1200 system opera Z tion capability is disabled E IDAS Trunk operation The IDAS Trunk system enables further effective channel management by sharing a minimum of channels with a large number of users Push Zone then push CH Up or CH Down to select the IDAS Trunk zone The method to select the desired zones may differ depending on your system set up Y NOTE During IDAS Trunk operation you can receive and Y transmit digital calls in the same way as IDAS operation I as described in M Receiving a call Transmitting a call NK IDAS OPERATION 3 WH E Receiving a call Receiving a Voice Call A DM When a Voice call is recei
12. er period When the channel type is Mixed Digital or Digital After receiving a digital signal you can select the same call type for the received call Individual or Talkgroup by pushing PTT before or during the talk back timer period 77 NOTE When the Talk Back function is not activated the trans ceiver transmits an analog signal on a Mixed Analog channel and transmits a digital signal on a Mixed Digital channel e The transceiver receives both analog and digital signals on the Mixed Analog and Mixed Digital channels regardless of this function MMM QAA MW E Transmitting a call IDAS operation allows you to make a call to a specific station Individual call or to a specific group Talkgroup call Other digital mode transceivers on the channel will not hear a call that does not match their Individual or Talkgroup ID and or RAN Radio Access Number code Transmitting a Voice Call D Push Digital Button to enter the application selection mode e VOICE appears e To change to the desired call type hold down Digital Button for 1 second while in standby After changing the transceiver auto matically enters the application selection mode This illustration shows an Individual type call IDAS OPERATION 3 2 Push Digital Button again to enter the Individual or Talk group ID selection mode e The preprogrammed ID name is displayed e When an ID name is not p
13. mit the message e MSG TK is displayed Release PTT e MSG Ok is displayed after receiving an acknowledgement from a base station e MSG FAIL is displayed if there is no acknowledgment from the base station 9 After a specified time period has passed the transceiver will return to standby Transmitting an Emergency Call When Emergency described in the instruction manual is held down for the specified time period the emergency signal is trans mitted once or repeatedly on the emergency channel When no emergency channel is specified the signal is transmitted on the operating channel When the Repeat Cancel function is ON the transceiver cancels repeat calling after receiving an acknowledgement When the Repeat Cancel function is OFF the transceiver continues to call according to the number of repeat cycles even after receiv ing an acknowledgement Individual or Talkgroup call types of emergency calls can be preset If the call type is not preset the default or selected call type is used If you want to cancel the emergency call hold down Emergency again before transmitting the call The emergency call can be transmitted without sounding beeps or changing the LCD display depending on the pre programming Silent operation The transceiver can also be programmed to keep the micro phone open during an emergency call allowing other stations to monitor the situation Ask your dealer for details
14. o is automatically transmitted for the set time period When a Radio Check command is received An acknowledgement call is automatically transmitted When a Status polling command is received e A status call is automatically transmitted Receiving an Emergency call 1 When an emergency call is received e Beeps sound e STAT EMR and the calling station ID name or code alternately appear e The state of the backlight depends on the Backlight setting in the User Set mode When LIGT AUT is selected the backlight turns ON for the preprogrammed time period Auto Backlight Timer ID name 2 To clear the beep ID and message display turn OFF the power or change the channel Displaying the received call log If activated the log stores received calls into the transceiver s memory Up to 10 calls can be stored and the oldest call record is erased when an 11th call is received However once the trans ceiver is turned OFF the log is erased The Individual voice call Call alert Status call and Message call are stored D Push Digital Button to enter the application selection mode e VOICE appears e To change to the desired call type hold down Digital Button for 1 second while in standby After changing the transceiver auto matically enters the application selection mode 2 Push CH Up or CH Down to select CALL LOG IDAS OPERATION 3 3 Push Digital Button again to
15. rets of Digital Voice Systems Inc This voice coding Technology is licensed solely for use within this Communications Equipment The user of this Technology is explicitly prohibited from attempting to extract remove decompile reverse engineer or disassemble the Object Code or in any other way convert the Object Code into a human readable form U S Patent Nos 5 870 405 5 826 222 5 754 974 5 701 390 5 715 365 5 649 050 5 630 011 5 581 656 5 517 511 5 491 772 5 247 579 5 226 084 and 5 195 166 TABLE OF CONTENTS IMPORTANT sic ceeecnstcexnectetcenedenentectetiertentticbteedneincoadceseiccutecoutede VOICE CODING TECHNOLOGY aana aaae nan na nana anana TABLE OF CONTENTS 0nenena renane naen anana anana anane anana aee ji T PREPARATION seerne 1 E Programmable function Keys rrrrrrrrrnnnrrvnnnnnrennnnnnnen 1 2 MDC 1200 OPERATION 2 universe 2 3 M MDC 1200 system operation rrrrrrurerrrnrerranrrrrnnnrernn 2 E Receiving a Cuur 2 E Transmitting a call asane eeee eee eee ene nane a ene e nane aane 3 3 IDAS OPERATION sesiis 4 16 E IDAS operation vene 4 E IDAS Trunk operation cccccsseeeeeeeeeeeeeeeeeeeeeeeeeeeeens 4 WE Receiving a call csiwisivosineniaanrnessetinartecatorinnetniasaeoedes 4 E Transmitting a CON EE ateatorsecaraetiorans 10 E Transmitting Position data errnnrnnrnrnnrrnnnnnnrnnnnnnnnr 15 E Transmitting Status message
16. rogrammed ID code is displayed e The primary ID can be preset to display first e When you want to make a voice call to all transceivers within the communication range use the All Call function select the Talkgroup ID code 65535 3 Push CH Up or CH Down to select a desired an ID name or ID code ID name is displayed 4 Hold down PTT then speak into the microphone 5 Release PTT to receive 10 11 3 IDAS OPERATION E Transmitting a call continued Transmitting a Call Alert Call Alert allows you to alert another user who may be away from their transceiver whom you want to talk to D Push Digital Button to enter the application selection mode e VOICE appears e To change to the desired call type hold down Digital Button for 1 second while in standby After changing the transceiver auto matically enters the application selection mode 2 Push CH Up or CH Down to select CALLALRT 3 Push Digital Button again to enter the Individual or Talk group ID selection mode e The preprogrammed ID name is displayed e When an ID name is not programmed the ID code is displayed e The primary ID can be preset to display first 4 Push CH Up or CH Down to select the desired ID name or ID code Individual or Talkgroup ID name is displayed 5 Hold down PTT to transmit the Call Alert to the selected station or Talkgroup e CA CALL is displayed
17. ved FE e Mute is released e While receiving the signal either the calling station or Talkgroup ID name or code can be displayed depending on the prepro gramming e When an All Call signal is received ALL CALL is displayed The calling station or gt Talkgroup ID name 2 Hold down PTT then speak into the microphone 3 Release PTT to receive 3 IDAS OPERATION E Receiving a call continued Receiving a Call Alert D When a Call Alert signal is received e Beeps sound e amp blinks The calling station or Talkgroup ID name or code and CALLALRT alternately appear Blinks The calling station or Ta Talkgroup ID name 2 Hold down PTT then speak into the microphone 3 Release PTT to receive Receiving a Status Message 1 When a Status Message is received e Beeps sound e The calling station or Talkgroup ID name or code and the sta tus message alternately appear vil The status message Talkgroup ID name 2 To clear the ID and message display push PTT turn OFF the power or change the channel Receiving a Message 1 When a Message is received Beeps sound e The calling station ID name or code and the message alter nately appear Talkgroup ID name NOTE When the message includes more than 8 characters and the automatic scroll function is activated the message automatically scrolls e Push Status Up