Installation and Service Manual 501 - 2071
Contents
1. 1 HOLO3NNOO 2 avaa BONVNAINIVW S938 yee fon i Ave Ave i Av3H 318VN3 38 0 i waviv i wa 1 nu 20 se ias 9 Fl 0 n
2. FIELD LOCATED MONITORED MONITORED IN POOL PIPING CONTINUOUSLY INTERMITTENTLY NOTE SHOWN WITH SHORTING BARS REMOVED AND ATTACHED DEVICES IN NON ALARM STATE EXAMPLE DEVICES HIGH LOW GAS AUX HI LIMIT AUX LIMITS EXT FLOW SWITCH c OPTIONAL PRESSUR RUN TIME PV E SWITCH FLAME PRESENCE MV R y VALVE S R Li PURGE SW PUMP ON OFF RELAY OFF 8L 0 O oN PR FIELD SUPPLIED LOUVER POWER VENTER CONNECTIONS COM CLOSED TEMPERATURE CONTROL MOTOR 1 PROVING contacts swircH REMOVE JUMPER 1 y 2 BL 2 24v AC 3 WIR 3 CLOSE 4SAMPS 5 5 5 5 4 4 OPEN Y LBRIW 4 1 4 4X4 eri _ 3 3 3Y3 3 WAY VALVE ACTUATOR 22 242 ITEM INDICATES is i ci 1 1 BKW 5 BRIW se RW 04 eR JUNCTION POINT NO1 PRIBK BRW ELECTRICALLY 3 i dd d CLOSED END SPLICE O PR PROUD Outlet Sensor DOTTED L
3. f 1 2 3 5 1 2 4 5 5 4 4 5 4 s NE NES 45 Commercial Pool Heaters OPERATION Continued Circulating Pump 1 This pool heater is factory supplied with a properly sized pump that circulates water between the pool heater and system The pump is sized to pool heater input and water hardness See Water Chemistry on page 44 Lubricate the pump to the manufacturer s recommendations Pump damage due to inadequate lubrication is non warrantable Use SAE 30 non detergent oil or lubricant specified by the pump manufacturer Standard pool heaters are furnished with the following circulating pump mounted in the factory supplied pool loop 500 000 750 000 Btu hr Models 1 4 HP 120 VAC 5 8 Amp 1 800 000 2 070 000 Btu hr Models 3 4 HP 120 VAC 8 8 Amp 990 000 1 440 000 Btu hr Models 1 2 HP 120 VAC 7 4 Amp This pump is sized based on installation of a single pool heater in close proximity with the system If the number of fittings and straight pipe exceeds the quantities shown in this section a larger pump will be required As an alternative to changing the pump in these circumstances the piping can be changed to a sub loop Check pump for correct pump rotation The standard pump selection is based on the following pipe and fittings from the pool heater to the system 6 90 elbows 2 unions 2 ball valves 1 cold water tee Not more than 45 feet of straight p
4. The display indicators on the Operating Temperature Control point to text on the overlay Figure 46 They indicate the following Damage to the pool heater including the pumped bypass Open Close These indicators appear when the Operating due to improper chemical water balance is non warrantable Temperature Control adjusts the position of the 3 way valve Proper chemical water balance as indicated by use of the calcium saturation and Ryznar indexes is required to maintain warranty status of the pool heater and its components These indexes are designed to help prevent scaling and corrosive damage to the pool and all associated equipment We recommend the use of a commercial or professional grade test kit to maintain chemical water balance See your local pool professional for assistance Active This indicator appears when the pool heater supplies heat to the pool 44 Installation and Service Manual Refer to Circulating Pump on page 46 for information relating Pipe Size Requirements to pump wiring The pipe sizing chart provides the minimum pipe size for common manifold piping to ensure adequate flow TABLE P AMP Draw Data Btu Hr Approximate TABLE Q Pipe Sizing Chart 500 000 750 000 Btu hr Models Common Pipe Number of Units Size Min 2 31 2 990 000 7 3 1 260 000 7 9 1 440 000 7 3 1 800 000 7 3 2 070 000 7 3 990 000 2 070 000 Btu hr Models Common Pipe Number of Units Size Min
5. 203 A22 3 501 2071 STAGE 1 1 imi BURNER i 2 P 501 2071 501 2071 LBL2296 Rev A 55 Commercial Pool Heaters LADDER DIAGRAM OPTIONAL PR MAN RESET ADJ HI LIMIT BL BR toot f T TEST SWITCH PROBE OPTIONAL HIGH LOW GAS LINE 120 VAC 15AMPS NEUTRAL doiz GROUND ON OFF 1 WARNING THIS HEATER MAY BE G POWER 2 CONNECTED TO ONE MORE BRANCH CIRCUIT BREAKER SWITCH CIRCUITS TO PREVENT ELECTRICAL SHOCK GROUND Y CRECEN Y TEIN OPTIONAL ALARI R P ALARM H Alarm Delay Connection oto H c Res R p CONTACTS PR PR PR A1 A2 B1 B2 OR FLOW l SWITCH FIELD INSTALLED SAFETY DEVICES B K ENSURE ALL BRANCH CIRCUITS ARE DE CHASSIS ENERGIZED BEFORE ATTEMPTING TO SERVICE 24 VAC 120 VAC BK THIS EQUIPMENT GROUND BL CHASSIS 2 Y S E SILENCE BELL24V OUTPU S OPTIONAL FLAME ALARM DELAY 991 2071 CURRENT BLOWER 2 TEST PINS IGNITER BURNER IGNITION MODULE HE ev Y
6. 3 VENT VALVE LOUVER OR VENTER DASHED LINE INDICATES OPTIONAL EQUIPMENT 24VAC PUMP RELAY CHASSIS GROUND CONNECTION DIAGRAM B 54 k sic MEET OPTIONAL R ek ALARM 1 2 2 2 PR BL T LIV ALARM BELL geeecssccccccecccceseccsccos OPTIONAL LOUVER VENTER OPTIONAL ALARM TIME DELAY TIME DELAY RELAY ON OFF POWER SWITCH Installation and Service Manual WIRING BOX CONNECTIONS MAIN UNIT CONNECTIONS oo S3 33 3 MAIN UNIT CONNECTOR 999 IGNITER i CONNECTOR Lwco 155 GYG GY D 0o00 PR 3 1 0 3 89 42 m P ww 188888 3 Bl CHASSIS CHASSIS H GROUND GROUND _ pe 9209 HIGH ii Gas NO COM NC SEE BLOWER BLOWER 2 1 991 2071
7. Use an accurate pool thermometer to monitor water temperature Use a time clock to start filter pump no earlier than 6 a m during pool season This is the time when nightly heat loss stabilizes Turn the pool heater OFF and drain during long periods when the pool will not be used winter vacations etc Follow a regular program of preventative maintenance for your pool heater each new swimming season Check heat exchanger controls burners and operation of the pool heater For pools used only on weekends the thermostat may be set lower than 78 F during the week Lower setting to a range that can be easily achieved in one day s operation of the pool heater SEQUENCE OF OPERATION OVERVIEW This sequence of operation can be considered the order of events in sequential order that occur after the pool heater has received a call for heat The process begins with 120 power entering the pool heater and ends with the pool heater going into an idle state after completion of a successful call for heat Note The following descriptions do not include remotely connected devices that may be connected to the pool heater Refer to the wiring diagram for actual point to point wiring connections that show power delivery 1 Place the POWER switch in the ON position 120VAC power is supplied to the control transformer along with L1 and F1 on the ignition module 24VAC is supplied to the adjustable high limit con
8. Specifications Set Point Adjustment Range OFF 55 F up to 105 F 13 C up to 41 C Differential Adjustment Range 1 F up to 20 F 1 C 11 C Temperature Accuracy 1 F Display Resolution 1 F via Liquid Crystal Display LCD Sensor NTC Thermistor 10k ohms 77 F 25 Operating Humidity 90 RH Non condensing Operating Ambient Temperature 20 to 140 F 30 to 60 The programming keys are as follows Select Allows the user to select the reading or parameter being displayed Each time the key is pressed a different indicator will appear which describes the value being shown These are detailed as follows Up and Down Arrows While in the Adjust mode the user can increase or decrease the parameter being shown The default display mode is the View mode indicated in the upper right hand corner of the display The default value shown is the Pool Temperature indicated by the arrow pointing to the POOL text on the overlay If the pool return sensor has been installed and connected this will be the temperature of the water coming from the pool Installation and Service Manual By pressing the Select key the Pool Target is shown and the text TARGET on the display This is the pool temperature set point By pressing the Select key again the Boiler Inlet Temperature is shown indicated by the text Boil In This is the temperature of the water going into the pool heater Not
9. 1 260 000 SVK3054 100 ft 1 440 000 SVK3054 100 ft N A 1 800 000 SVK3055 100 ft N A 2 070 000 SVK3055 100 ft N A These kits include a sidewall venter assembly vent termination and barometric damper 990 000 2 070 000 Btu hr models only 4 Horizontal DirectAire Venting IMPORTANT Before installing a venting system follow all venting clearances and requirements found in the Venting General Information section page 10 The Horizontal DirectAire vent system is the same as the Sidewall Venting system except it pulls combustion air from the outdoors through a sidewall air inlet Follow all requirements in Sidewall Venting page 17 The Horizontal DirectAire vent system requires you to install two vent pipes directly to the pool heater one pipe for flue products and one for combustion air Install both vent pipes horizontally with a sidewall termination point For this venting option you must purchase the DV box accessory from the pool heater manufacturer The DV box attaches to the air inlet of the pool heater The pipe for combustion air attaches to the DV box Make vent connection directly to the top of the pool heater No additional draft diverter or barometric damper is required on single unit installations with a dedicated stack and a negative draft maintained between 0 04 to 0 08 inches w c The Horizontal DirectAire combustion air supply system has specific vent
10. All dimensions are based on net free area in square inches Metal louvers or screens reduce the free area of a combustion air opening a minimum of approximately 2596 Check with louver manufacturers for exact net free area of louvers Where two openings are provided one must be within 12 30 cm of the ceiling and one must be within 12 30 cm of the floor of the equipment room Each opening must have a minimum net free area as specified in TABLE C page 12 Single openings shall be installed within 12 30 cm of the ceiling The combustion air supply must be completely free of any flammable vapors that may ignite or chemical fumes which may be corrosive to the pool heater Common corrosive chemical fumes which must be avoided are fluorocarbons and other halogenated compounds most commonly present as refrigerants or solvents such as Freon trichlorethylene perchlorethylene chlorine etc These chemicals when burned form acids which quickly attack the heat exchanger finned tubes headers flue collectors and the vent system The result is improper combustion and a non warrantable premature pool heater failure Exhaust Fans Any fan or equipment which exhausts air from the equipment room may deplete the combustion air supply and or cause a downdraft in the venting system Spillage of flue products from the venting system into an occupied living space can cause a very hazardous condition that must be immediately corrected If a fan is
11. A clay tile lined chimney must be structurally sound straight and free of misaligned tile gaps between liner sections missing sections of liner or any signs of condensate drainage at the breaching or clean out If there is any doubt about the condition of a masonry chimney it must be relined with a properly sized and approved chimney liner system An unlined masonry chimney must not be used to vent flue products from this high efficiency pool heater An unlined chimney must be relined with an approved chimney liner system when a new pool heater is being attached to it Metallic liner systems Type B doublewall or flexible or rigid metallic liners are recommended Consult with local code officials to determine code requirements or the advisability of using or relining a masonry chimney Vertical Vent Termination Clearances and Location Follow all vertical venting termination information for clearances and location under Vertical Vent Termination Clearances and Location page 10 2 Vertical DirectAire Venting IMPORTANT Before installing a venting system follow all venting clearances and requirements found in the Venting General Information section page 10 The Vertical DirectAire vent system is the same as the Conventional Negative Draft vent system except it pulls combustion air from the outdoors through a sidewall or vertical air inlet Follow all requirements in Conventional Negative Draft Venting page 14 The Ver
12. COPPER OR CPVC SEE TABLE 20 MAXIMUM MINIMUM TO POOL ALTERNATE POOL RETURN SENSOR LOCATION Figure 34 Heater is Within 15 Feet of Pool Piping MODELNO BYPASS PIPE SIZE CP N L 501 751 2 MINIMUM CP N L 991 2071 2 1 2 MINIMUM FACTORY POOL RETURN SENSOR LOCATION AUTOMATIC BYPASS VALVE PVC SEE TABLE RECOMMENDED ISOLATION VALVE FROM FILTER OR FOUR PIPE DIAMETERS MAXIMUM 20 MAXIMUM SEE TABLE TO POOL ALTERNATE POOL RETURN SENSOR LOCATION Figure 35 Heater is Beyond 15 Feet of Pool Piping 33 Commercial Pool Heaters INSTALLATION Continued MODEL NO BYPASS PIPE SIZE CP N L 501 751 2 MINIMUM ORY POOL CP N L 991 2071 2 1 2 MINIMUM RETURN SENSOR LOCATION AUTOMATIC BYPASS VALVE PVC SEE TABLE Lt GS FROM FILTER A BOO Ot Qu s D RPL y COPPER OR CPVC ES SEE TABLE RECOMMENDED ISOLATION VALVE COPPER OR CPVC SEE TABLE 110 LIMIT MINIMUM ALTERNATE POOL RETURN SENSOR LOCATION A TO POOL Figure 36 Heaters are within 15 feet Perpendicular of Pool Piping MODEL NO BYPASS PIPE SIZE ge re FROM FILTER NOS ALTERNATE POOL _ RETURN SENSOR CP N L 501 751 2 MINIMUM LOCATION CP N L 991 2071 2 1 2 MINIMUM 3 MINIMUM TO POOL RECOMMENDED ISOLATION VALVE FACTORY POOL RE
13. 04 to 0 08 inches w c while the pool heater is operating Flue Outlet Piping With this venting option you must use Type B doublewall or equivalent vent materials Vent materials must be listed by a nationally recognized test agency for use as vent materials Make the connections from the pool heater vent to the sidewall fan cap as direct as possible with no reduction in diameter Use the National Fuel Gas Code venting tables for doublewall vent to properly size all vent connectors and stacks Follow the vent manufacturer s instructions when installing Type B vents and accessories such as firestop spacers vent connectors thimbles caps etc When planning the venting system avoid possible contact with plumbing or electrical wiring inside walls The maximum installed length of sidewall vent pipe with an induced draft fan must not exceed 100 feet 30 5m on the 500 000 2 070 000 Btu hr models Note Models 990 000 2 070 000 are not approved for sidewall venting without a fan The maximum installed length of sidewall vent pipe without an induced draft fan must not exceed 50 feet 15 2m on the 500 000 750 000 Btu hr models Subtract 5 feet 1 5m for each 90 elbow Subtract 2 5 feet 0 7m for each 45 elbow Sidewall Venting Termination The sidewall vent cap must be installed on an exterior sidewall The sidewall fan powered sidewall vent cap and accessories are included in a venting kit which is furnished by the pool hea
14. 10 feet 3 05m of the flue outlet from the powered vent cap Make sure to properly install the air inlet cap assembly on the air inlet pipe You must install the combustion air inlet cap and the powered vent cap on the same wall and in the same pressure zone Do not install the combustion air inlet cap closer than 10 feet 3 05m from an inside corner of an L shaped structure 13 Vertical Rooftop Air Inlet Use the vertical air inlet terminations available from the pool heater manufacturer recommended and or supplied by the vent manufacturer or use two 90 elbows as described on page 24 3 aa al Figure 16 Roof Top Combustion Air Inlet Clearances You must locate the air inlet termination elbow at least 12 30cm above the roof or above normal snow levels If the air inlet cap is within a 10 foot 3 05m radius of the flue outlet the point of termination for the combustion air inlet cap must be at least 3 feet 0 91m below the point of flue gas termination vent cap Do not install the combustion air inlet cap closer than 10 feet 3 05m from an inside corner of an L shaped structure Combined Air Inlet Points The air inlet pipes from multiple pool heaters can be combined to a single common connection if the common air inlet pipe has a cross sectional area equal to or larger than the total area of all air inlet pipes connected
15. barbed fitting on the deck of the pool heater see Figure 31 Remove the flexible cap from the barbed fitting on the tee located in this line and hook one side of the manometer or side of a magnahelic gauge to this tee Retain this cap for future use MANIFOLD PRESSURE PRESSURE REGULATOR ADJUSTMENT UNDER CAP SCREW BARBED CHAMBER PRESSURE FITTING GAS VALVE CONTROL KNOB 1 8 HEX MANIFOLD PRESSURE OUTLET Figure 31 Measuring Net Manifold Gas Pressure 30 6 Remove the 1 8 hex plug from the manifold pressure tap on the gas valve see Figure 31 Retain plug for future use Install a fitting in this tap that is suitable for connection of a hose to a manometer or side of a magnahelic gauge see Figure 31 Turn the power switch to the I or ON position Push the reset button s for the ignition control s if necessary 10 Set the temperature control to call for heat see Programming Temperature Control page 41 11 Once the pool heater is firing the manometer magnahelic will reflect the Manifold Gas Pressure Compare this reading to the respective value in TABLE L page 31 for Natural or Propane Gas 12 If adjustment is necessary remove the regulator cover screw on the gas valve Note If the gas valve under adjustment is located on a manifold assembly monitored by an igniter the poo
16. combustion process Check this filter every month and replace The filter size on the 500 000 750 000 Btu hr models is 12 x 12 x 1 30 5cm x 30 5cm x 2 5cm and 16 x 16 x 1 40 6cm x 40 6cm x 2 5cm on the 990 000 2 070 000 Btu hr models You can find these commercially available filters at any home center or HVAC supply store Venting System Examine the venting system at least once a year Check more often in the first year to determine inspection interval Check all joints and pipe connections for tightness corrosion or deterioration Clean screens in the venting air intake system as required Have the entire system including the venting system periodically inspected by a qualified service agency Air Flow Check frequently to be sure the flow of combustion and ventilation air to the pool heater is not obstructed Installation and Service Manual Combustion Air Fans Both the 500 000 750 000 Btu hr models and the 990 000 2 070 000 Btu hr models use a fan assisted combustion process The 500 000 750 000 Btu hr models have one fan and the 990 000 2 070 000 Btu hr models use two fans to supply combustion air to the burners Fan Cleaning Check each combustion air fan every six months Clean the fan as required when installed in a dusty or dirty location Oiling is not required Combustion Air Fan Adjustment The combustion air fans are factory pre set and should not need adjustment in most cases Fol
17. corrected the ignition module will continue in the soft lockout condition If the thermostat opens during the soft lockout period the ignition module will exit soft lockout and wait for a new call for heat from the thermostat A soft lockout condition may also be reset by manually cycling the thermostat or turning the main power switch OFF and then ON after the control sensed fault has been corrected Figure 47 Hot Surface Igniter 54 ew 8 S 9 Diagnostic Status Indication L J J The ignition module has an LED which indicates the status of Figure 48 Hot Surface Ignition Control Module the safety circuits A remote Ignition Module Status indicating light is wired from the ignition module Status LED and mounted on the front control panel The flashing operation of this light LED indicates the diagnostic status of the ignition control module The status LED mounted on the ignition module flashes a code sequence from the Ignition Module to indicate the status of the ignition process See TABLE N on page 43 for the flashing diagnostic status codes as signaled by the ignition module 42 Installation and Service Manual TABLE N Ignition Control Diagnostic Codes Code Sequence Condition Constant ON Constant OFF System OK no faults present Possible c
18. exchanger can be removed by sliding towards the front of the pool heater Once the heat exchanger is removed from the pool heater a garden hose can be used to wash the tubes to ensure that all soot is removed from the heat exchanger surfaces 48 Note Do not wet the pool heater s refractory 8 Ensure that all burner ports are cleaned to remove any soot See Burner Removal and Cleaning this page 9 Carefully reinstall the heat exchanger V baffles and frame runners if removed from the pool heater Note Make sure frame runners seal securely where they contact the front and rear compartment refractory 10 Carefully reinstall inner jacket panels burners manifolds wires and hoses Use new gasket material to ensure a proper air seal 11 Reassemble all gas and water piping Test for gas leaks 12 Reassemble outer jacket panels 13 Cycle the pool heater and check for proper operation Electrical This pool heater uses a transformer to supply a low voltage control circuit The voltage on the secondary side should be 24 to 28VAC when measured with a voltmeter This unit has a 7 AMP circuit breaker provided on the secondary side of the transformer A tripped circuit breaker indicates a short in the 24VAC controls that must be corrected Combustion and Ventilation Air Combustion Air Filter This unit has a standard air filter located at the combustion air inlet This filter helps ensure clean air is used for the
19. heater to the vent cap Horizontal Vent Termination Clearances and Location Follow all sidewall venting termination information for clearances and location under Sidewall Vent Termination Clearances and Location page 11 TABLE G DirectAire Kits Btu hr Kit Kit The DVK kit includes a DV box adapter air inlet cap and a sidewall vent termination The VDK kit includes a DV box adapter and an air inlet cap See note on page 12 concerning DV box adapter Flue Pipe Materials The following manufacturers supply flue materials suitable for these models All materials are made with AL29 4C stainless steel Call the numbers below for the nearest distributor Heat Fab Inc Saf T CI Vent 1 800 772 0739 Protech Systems Inc Fas N Seal Vent 1 800 766 3473 Metal Fab Inc Corr Guard Vent 1 800 835 2830 Combustion Air Inlet Piping The Direct Vent system requires the installation of a pipe to supply combustion air from the outdoors directly to the pool heater The air inlet piping can either be brought in horizontally from a sidewall or vertically from the rooftop Make sure the combustion air inlet is in the same pressure zone as the vent terminal Installation and Service Manual In cold climates use a Type B doublewall vent pipe or an insulated single wall pipe for combustion air This will help prevent moisture in the cool incoming air from condensing and leaking from the inlet pipe A CAUTION Pool heaters t
20. instructions when installing Type B vents and accessories such as firestop spacers vent connectors thimbles caps etc Provide adequate clearance to combustibles for the vent connector and firestop When planning the venting system avoid possible contact with plumbing or electrical wiring inside walls ceilings and floors Locate the pool heater as close as possible to a chimney or gas vent Avoid long horizontal runs of the vent pipe 90 elbows reductions and restrictions No additional draft diverter or barometric damper is required on single unit installations with a dedicated stack and a negative draft maintained between 0 02 to 0 08 inches w c Common Venting Systems You can combine the flue with the vent from any other negative draft Category I appliance Using common venting for multiple negative draft appliances requires you to install a barometric damper with each pool heater This will regulate draft within the proper range You must size the common vent and connectors from multiple pool heaters per the venting tables for Type B doublewall vents in the latest edition of the National Fuel Gas Code ANSI 7223 1 and or CAN CGA B149 Installation Code Common venting systems may be too large when an existing pool heater is removed At the time of removal of an existing pool heater the following steps shall be followed with each pool heater remaining connected to the common venting system placed in operation while ot
21. key in the Adjust mode while viewing the Pool DIFF setting the Boiler Inlet Minimum setting will be displayed indicated by the text BOIL IN MIN in the display The control will adjust the position of the 3 way automatic bypass valve in order to maintain the inlet temperature at this setting The default is 130 F By pressing the Select key again the Boiler Maximum setting will be displayed indicated by the text BOIL MAX in the display The control will shut off the heater whenever the outlet temperature from the heater exceeds this setting The default value is 200 F If a Pool Supply sensor is connected then by pressing the Select key again the Supply Target setting will be displayed 59 Accumulated runtime hours indicated by the text SUP TARGET in the display The control will shut off the heater whenever the pool supply temperature exceeds this setting The default value is 100 F If a Pool Supply sensor is connected then by pressing the Select key again the Supply Differential setting will be displayed indicated by the text SUP DIFF in the display After the control has turned off the heater because the pool supply temperature exceeded the Pool Supply setting the pool supply temperature must drop by this amount before the control will allow the heater to start up again The default value is 20 F By pressing the Select key again the Valve Speed setting will be displayed indicated by the arrow pointing to the text SPEED
22. may occur 36 Installation and Service Manual ALARM ENABLE RELAY OPT FLAME FAILURE ENABLE WIRE HARNESS CONNECTIONS A FIN eS 1 BREAKER La s l DIAGNOSTIC STD 8 3 14 7 DISPLAY STD 9 lo e 1e TRANSFORMER STD lo e STD Lue arts CONTROLLER STD RUNTIME RELAY OPT LWCO WIRE HARNESS CONNECTIONS OPT L HIGH LIMIT IGNITION MODULE STD STD Figure 39 Control Panel Component Location Drawing TABLE M Remote Wire Connection Gauge Allowable Length Terminal Strip Connection Options The scenarios shown in Figures 40 A C represent typical terminal strip connection requirements The terminal strips are located on the left side of the pool heater under the electrical access panel Other applications may be accommodated but must be addressed individually 16 GA 18 GA Figure 40 A shows the position of the jumpers as shipped from the factory for stand alone operation of the pool heater Figure 40 B shows connections to the terminal strip for Remote ON OFF control of the pool heater The 1C 1NO jumper must be removed when making these wiring connections This remote ON OFF control will provide an Enable Disable signal to the pool heater and allow the
23. of BTU s per hour for gas pressures of 14 Inches Water Column 0 5 PSIG or less and a total system pressure drop of 0 5 Inch Water Column Based on NAT GAS 1025 BTU s per Cubic Foot of Gas and 0 60 Specific Gravity N o 29 Commercial Pool Heaters INSTALLATION Continued Gas Manifold Pressure Adjustment IMPORTANT The gas valves are referenced to the fan pressurized chamber by a hose connected from the vent of the gas valve regulator to the chamber pressure tap located on the front inside portion of the jacket Reference the drawings in this section for component and connection points for pressure measurement The procedure for connecting a manometer or magnahelic must be followed to obtain actual net manifold pressure for normal operation A manometer or magnahelic gauge legible in 0 1 increments up to 10 inches w c is required to check and adjust the manifold pressure The regulator cover screw on the gas valve must be in place and tight at all times for the pool heater to operate properly 1 Remove the thumbscrew that fastens the control panel access door and pull out the control panel Turn the power switch located in the lower left corner behind the control panel access door to the O or OFF position Remove the top front jacket access panels to access the gas valves Locate the reference hose on the second gas valve which goes from the vent fitting on the gas valve to a
24. pool heater to operate based on the set point until the remote ON OFF signal is cancelled If the remote ON OFF control is also an external pool temperature control adjust the pool heater s pool return set point a few degrees higher than the external pool temperature control s set point The pool heater temperature control will then act as a backup to the external pool temperature control 37 Figure 40 C shows the Continuous and Intermittent terminals External safety devices connected to these terminals will function to protect the pool heater Devices connected to the Intermittent terminals 1 and B2 are monitored only when there is an active Call for Heat Devices connected to the Continuous terminals A1 and A2 are monitored continuously and will activate and alarm if the pool heater is equipped with the alarm option anytime the safety device senses an abnormal condition An additional wire may be field installed from these safety devices to terminals A3 or B3 as appropriate to activate an audible alarm if the pool heater is equipped with the alarm option HEATDEM1 HEATDEM2 STAGE1 STAGE2 srAGE3 STAGE4 1 1 2 2NO 3 3NO 4 4NO CONTINUOUS INTERMITTENT hecaeorl E E KA CC ih a eB SS e A1 A2 A3 B1 B2 B3 e Commercial Pool Heaters INSTALLATION Continued NOT USED ON 2 POOL HEATER 5 REMOTE O
25. proper gas supply and ensure adequate supply of combustion and ventilation air Flue Gas Passageways Cleaning Procedures Any sign of soot around the refractory at the burners or in the areas between the fins on the copper heat exchanger indicates a need for cleaning The following cleaning procedures must only be performed by a qualified serviceman or installer Proper service is required to maintain safe operation Properly installed and adjusted pool heaters seldom need flue cleaning IMPORTANT gaskets on disassembled components must be replaced with new gaskets on reassembly Gasket kits are available from your distributor Commercial Pool Heaters CLEANING AND MAINTENANCE Continued Burner Removal and Cleaning 1 2 3 4 Turn OFF the main power to the pool heater Turn OFF the main manual gas shutoff to the pool heater Remove the front outer jacket panels Disconnect the manifold from the gas train using the union s just below each gas valve s Remove the mounting nuts from the manifold mounting brackets Pull the manifold orifice assembly away from the burners Repeat for each manifold assembly Remove two mounting screws from the burner and slide the burner out toward the front of the pool heater Use caution to prevent damage to burners refractory hot surface igniter or wiring Remove soot from the burners with a stiff bristle brush Dirt may be removed from
26. proper pipe size for your pool heater A list of sealed AL29 4C flue pipe manufacturers is located on page 22 Seal all vent joints and seams gas tight Drain Tee Installation A drain tee must be installed in the vent pipe to collect and dispose of any condensate that may occur in the vent system The drain tee must be installed as the first fitting after the horizontal ell on the top of the unit see Figure 22 Plastic drain tubing sized per the vent manufacturer s instructions shall be provided as a drain line from the tee The drain tubing must have a trap provided by a 3 7 6cm diameter circular trap loop in the drain tubing Prime the trap loop by pouring a small quantity of water into the drain hose before assembly to the vent Secure the trap loop in position with nylon wire ties Use caution not to collapse or restrict the condensate drain line with the nylon wire ties The condensate drain must be routed to a suitable drain for disposal of condensate that may occur in the direct vent system Refer to the condensate drain installation instructions as supplied by the manufacturer of the vent material Installation and Service Manual 4 MIN Figure 22 Sidewall Venting WARNING Do not combine the flue from this unit with the vent from any other appliance Do not combine flues from multiple appliances into a common vent The flue from this unit must
27. range by pressing the Up or Down Arrow key The default display shows the Pool Target temperature indicated by the arrow pointing to the text POOL on the overlay and the text TARGET on the display This is the temperature of the water from the pool at which the pool heater will turn off The default is 85 F 27 C By pressing the Select key again the Pool Differential temperature is shown indicated by the arrow pointing to the text POOL on the overlay and the text DIFF on the display This is the number of degrees below the Pool Target temperature that the pool temperature must drop before the pool heater will turn on The default is 4 F 2 C By pressing the Select key again the Temperature Units will be displayed indicated by the text F or C This is the units in which the temperatures are shown The default is F 41 By pressing the Select key again the Pool Target will be shown once more To return to the View mode simply stop pressing any buttons for 25 seconds Note The control values programmed into memory will not be lost because of a power failure Error Messages Displayed by the Temperature Controller There are six error messages that can be displayed in response to software or hardware problems with the pool heater s internal temperature control The error codes that may be seen on the display are E01 The internal memory of the microprocessor in the temperature control has a read error at power up T
28. to the common air inlet pipe Example Two 10 air inlet pipes 78 5 in area each have a total area of 157 in and will require a 15 176 7 in area common air inlet pipe The air inlet point for multiple pool heater air inlets must be provided with an exterior opening which has a free area equal to or greater than the total area of all air inlet pipes connected to the common air inlet This exterior opening for combustion air must connect directly to the outdoors The total length of the combined air inlet pipe must not exceed a maximum of 50 15 2m equivalent feet Subtract 5 feet 1 5m for each 90 elbow in the air inlet pipe You must deduct the restriction in the area provided by any screens grills or louvers installed in the common air inlet point These are common on the sidewall air inlet openings Screens grills or louvers installed in the common air inlet can reduce the free area of the opening from 2596 to 7596 based on the materials used Commercial Pool Heaters INSTALLATION Continued Vent System Options This pool heater has six venting options 1 Conventional Negative Draft Venting This option uses a vertical rooftop flue termination Combustion air is supplied from the equipment room Vertical DirectAire Venting This option uses a vertical conventional vent for flue products Combustion air is supplied by a pipe from the sidewall or rooftop See page 16 for venting details Sidewall Venting This optio
29. using the regulator located on the valve A manifold gas pressure tap for each burner stick is located on the discharge side of the valve aters The manifold pressure is preset at the factory and adjustment is not usually required If you must adjust regulator pressure follow the instructions under Gas Manifold Pressure Adjustment page 30 Venting of Combination Gas Valves The combination gas valve regulator used on these pool heaters is equipped with an integral vent limiting orifice per ANSI Z21 78 The vent limiter ensures that the volume of gas emitted from the valve in the event of a failed gas diaphragm does not exceed the maximum safe leakage rate allowed by agency requirements Combination gas valve regulators equipped with integral vent limiters are not required to have vent or relief lines piped to the outdoors Checking Gas Supply Pressure Use the following procedure to check gas supply pressure Turn the main power switch to the OFF position Turn gas valve knobs to the OFF position Shut off gas supply at the field installed manual gas cock in the gas piping to the pool heater If fuel supply is L P gas shut off gas supply at the tank Remove the 1 8 hex plug located on the inlet side of any gas valve You may also use a tapping on the field installed main manual gas cock or gas piping Install a fitting in the inlet pressure tapping suitable to connect to a manometer or magnahel
30. 14 cm 2070 in 13 356 cm Outside air openings shall directly communicate with the outdoors When combustion air is drawn from the outside through a duct the net free area of each of the two openings must have twice 2 times the free area required for Outside Air 2 Openings The above requirements are for the boiler only additional gas fired units in the boiler room will require an increase in the net free area to supply adequate combustion air for all units Combustion air requirements are based on the latest edition of the National Fuel Gas Code ANSI Z223 1 in Canada refer to CAN CGA B149 Installation Code Check all local code requirements for combustion air 12 Installation and Service Manual poe su Figure 14 Sidewall Combustion Air Inlet Figure 15 Air Inlet Cap for Sidewall Termination To prevent recirculation of flue products from an adjacent vent cap into the combustion air inlet follow all applicable clearance requirements in the latest edition of the National Fuel Gas Code and or CAN CGA B149 Installation Code and instructions in the Installation and Service Manual You must install the combustion air inlet cap at least one foot 0 30m above ground level and above normal snow levels The point of termination for the combustion air inlet cap must be at least 3 feet 0 91m below the point of flue gas termination powered vent cap if it is located within
31. A WARNING Do not attempt to repair a faulty hot surface igniter or ignition module Any modification or repairs may create hazardous conditions that result in property damage personal injury fire explosion and or toxic gases A faulty hot surface igniter or ignition module must be replaced with an identical part A specification igniter and ignition control module for this specific pool heater is available from your local distributor Do not use general purpose field replacement ignition modules or igniters Ignition System Checkout 1 Turn OFF the gas supply to the pool heater 2 Turn the electric power ON 3 Program the temperature control to settings above water temperature or to the highest safe setting 4 The igniter will cycle on trial for ignition 5 The ignition module will lock out and turn the alarm light on 6 Program the temperature control to the desired temperature set point 7 Turn ON the gas supply 8 Press the module reset button located on the front of the unit to reset the module 9 If ignition system fails to operate properly repair work must be performed by a qualified serviceperson or installer 50 Installation and Service Manual ENERGY SAVING RECOMMENDATIONS 1 Keep the pool covered when not in use This will cut heating cost reduce water evaporation conserve chemicals and reduce load on the filtering system Reduce pool thermostat to 78 F or lower
32. CPE I S 14 INSTALLATION AND SERVICE MANUAL GAS HEATERS FOR COMMERCIAL POOL APPLICATIONS 500 000 2 070 000 Btu hr MODELS CERTIFIED Starting Serial 2F0600187510 WARNING Do not use this pool heater if any part has been under water The possible damage to a flooded pool heater can be extensive and present numerous safety hazards Any pool heater that has been under water must be replaced WARNING Improper installation adjustment alteration service or maintenance can cause property damage personal injury exposure to hazardous materials or loss of life Refer to this manual Installation and service must be performed by a qualified installer service agency or the gas supplier This pool heater contains materials that have been identified as carcinogenic or possibly carcinogenic to humans A WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life This appliance MUST NOT be installed in any location where gasoline or flammable vapors are likely to be present unless the installation is such to eliminate the probable ignition of gasoline or flammable vapors WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbors phone Follow the gas sup
33. Direct Vent installation requirements including the components used and vent kit part numbers Flue Outlet Piping Venting Guidelines If using this venting option a sealed AL29 4C venting system for flue products is required on all models of this pool heater This venting system operates with a positive pressure in the vent The internal combustion air blowers generate this positive pressure which operates the combustion process and also exhausts the flue products from the building This vent system has specific vent material and installation requirements Only use listed sealed AL29 4C vent system materials Follow all installation requirements See TABLE B page 11 for proper pipe size for your pool heater A list of sealed AL29 4C flue pipe manufacturers is located on page 22 Seal all vent joints and seams gas tight 21 Drain Tee Installation A drain tee must be installed in the vent pipe to collect and dispose of any condensate that may occur in the vent system The drain tee must be installed as the first fitting after the horizontal ell on the top of the unit see Figure 23B Plastic drain tubing sized per the vent manufacturer s instructions shall be provided as a drain line from the tee The drain tubing must have a trap provided by a 3 7 6cm diameter circular trap loop in the drain tubing Prime the trap loop by pouring a small quantity of water into the drain hose before assembly to the vent Secure the trap loop in
34. INE W m BR Inlet Sensor INDICATES OPTIONAL EQUIPMENT LOUVER VENTER H W WHITE T TAN BK BLACK Y YELLOW A NABLE CONTACT RELAY OPTIONAL RELAYS LOCATED IN WIRING BOX OPTIONAL DIN RAIL CONNECTORS a m r gt lt o r o o 2 A a r v z m LEDS LOCATED ON DISPLAY BOARD PR PURPLE BL BLUE P PINK O ORANGE VENT VALVE Y G YELLOW WITH GREEN STRIPE BR BROWN G GREEN GY GRAY R RED NOTES 1 WHERE POSSIBLE ALL SWITCHES AND CIRCUITRY ARE SHOWN IN THEIR AT REST STATES 2 ADDITION OF ENERGY MANAGEMENT SYSTEMS OR OPTIONAL LIMIT SWITCHES TO THE TERMINAL STRIP REQUIRE THE REMOVAL OF SOME OF THE SHORTING BARS FROM THE TERMINAL STRIP 3 REFER TO ACTUAL COMPONENTS FOR EXACT TERMINAL LOCATIONS LOCATED IN ELECTRICAL WIRING BOX 4 WHEN REPLACING DAMAGED WIRING USE EQUIVALENT TYPE AND GAUGE CP LBL20010 REVA 56 Installation and Service Manual CONTROL BOX CONNECTIONS A38 110027197 V NOLLO3NNOO H YOLOANNOD O LIMS LASIX INIVWHOIWHSS LINN 4
35. N OFF 2 a o o 1 B kc E 1C 1NO 2C 2NO 3C 3NO 4C 4NO CONTINUOUS INTERMITTENT r d m o B3 e e HEATDEM1 HEATDEM2 e STAGE1 STAGE2 STAGE3 STAGE4 opel ol p pc tae p NV MS ae Sie a aS ee IV 1C 1NO 2C 2NO 3C 4C 4NO CONTINUOUS INTERMITTENT a A1 A2 B1 B2 B3 e CONTINUOUSLY INTERMITTENTLY MONITORED MONITORED EXAMPLE DEVICES HIGH LOW GAS AUX HI LIMIT AUX LIMITS EXT FLOW SWITCH Figure 40 A C Terminal Strip Connection OPERATION FOR YOUR SAFETY READ BEFORE OPERATING AN WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life WHAT TO DO IF YOU SMELL GAS Do to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions f you cannot reach your gas supplier call the fire department C Useonly your hand to turn the gas control lever Never use tools If the lever will not turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use this pool heater if any part has been under water Immediately call a qualified service technician to replace the pool heater The possible damag
36. OG 1 i F ya ud A d d OL ya b Aud 1 a mx esi Bl 6 OH i 2827 i H 1 mei Pu i no NOWWOO OW j I E i 1 lo lo 1 sion Avz gt i A i gt u MINJX OVAVZ S ssvH9 wos sg ss 2 Ek AV ldSId Ce iw 4 3ALLOV T E T 588 sal 19 Aaea Im m Sd t NE MHO193NNOO Hnnmnmmmmmm E E Hn AW Av 130 ovaz 9 waviv 19899 2 18 s 5 a DO else PODE TIR oe T xs na HL or Tis 4 D B QTO 4 TILES 9 4 A n LL ST m 35012 alo oola NOE me wn EE 1 vie p Oow 01010100 OL Bi ouvWoinv 88 V Ly 60 O OO Gey M 23 isle edo c uy vlt H M ld 007 ONIdid NI 12 1 GALVIOTAATIVA 99vZ B aps SHOLO3NNOO HOSN3S E HOLO3NNOOD 9NIHIM SNOILOANNODO XO 57 Commercial Pool Heaters Appendix A Unit Start Up Checklist Ensure that the location a
37. TURN SENSOR LOCATION AUTOMATIC L BYPASS VALVE 7 COPPER OR CPVC 7 SEE TABLE Figure 37 Heaters Beyond 15 feet of Pool Piping 34 Installation and Service Manual MODEL NO BYPASS PIPE SIZE ALTERNATE POOL RETURN SENSOR CP N L 501 751 2 MINIMUM CP N L 991 2071 2 1 2 MINIMUM OPTIONAL POOL SUPPLY SENSOR LOCATION MINIMUM 110 LIMIT TO POOL LOCATION FACTORY POOL RETURN SENSOR LOCATION Pd RECOMMENDED ISOLATION VALVE COPPER OR CPVC SEE TABLE Figure 38 Multi Stack Frame Heaters are Beyond 15 feet from Pool Piping Relief Valve This pool heater is supplied with a relief valve s sized in accordance with ASME Boiler and Pressure Vessel Code Section IV The relief valve s is installed in the vertical position and mounted in the hot water outlet Place no other valve between the relief valve and the pool heater To prevent water damage pipe the discharge from the relief valve to a suitable floor drain for disposal when relief occurs Do not install any reducing couplings or other restrictions in the discharge line The discharge line will allow complete drainage ofthe valve and line Manually operate the relief valves at least once a year A CAUTION Avoid contact with hot discharge water Automatic Chlorinator and Chemical Feeders All chemical
38. all tubing bends smooth and without deformation Avoid flexible gas connections Internal diameter of flexible lines may not provide the pool heater with the proper volume of gas For ease of service install a union Install a manual main gas shutoff valve at the pool heater s gas inlet outside of the pool heater in accordance with the National Fuel Gas Code ANSI Z223 1 this must be installed within 6 feet of the pool heater GROUND JOINT UNION MANUAL MAIN SHUT OFFVALVE USE WRENCH TO HOLD PIPING SEDIMENT TRAP Figure 28 Gas Line Connection 5 10 11 Run pipe or tubing to the pool heater s gas inlet If you use tubing obtain a tube to pipe coupling to connect the tubing to the pool heater s gas inlet Install a sediment trap in the supply line to the pool heater s gas inlet see Figure 28 Apply a moderate amount of good quality pipe compound do not use Teflon tape to pipe only leaving two end threads bare Remove the seal over the gas inlet to the pool heater Connect the gas pipe to the inlet of the pool heater Use a wrench to support the gas manifold on the pool heater For L P gas consult your L P gas supplier for expert installation Ensure that all air is completely bled from the gas line before starting the ignition sequence Start up without properly bleeding air from the gas line may require multiple reset functions of the ignition control module t
39. be a dedicated stack Connect the flue vent directly to the flue outlet opening on the top of the pool heater Make the connections from the pool heater vent to the outside stack as direct as possible with no reduction in diameter Provide adequate clearance to combustibles for the vent connector and firestop Follow the vent manufacturer s instructions when installing sealed AL29 4C vents and accessories such as firestop spacers vent connectors thimbles caps etc Provide adequate clearance to combustibles for the vent connector and firestop When planning the venting system avoid possible contact with plumbing or electrical wiring inside walls ceilings and floors Locate the pool heater as close as possible to the chimney or gas vent When a vent system is disconnected for any reason the flue must be reassembled and resealed according to the vent manufacturer s instructions The installed length of flue from the pool heater to the outside point of termination must not exceed 50 equivalent feet 15 2m Subtract 5 feet 1 5m of equivalent length for each 90 elbow Subtract 2 5 feet 0 7m of equivalent length for each 45 elbow 19 Masonry Chimney Installation Do not use a standard masonry chimney to directly vent the combustion products from this pool heater To use a masonry chimney the chimney must use a sealed corrosion resistant liner system Sealed corrosion resistant liner systems singlewall doublewall flexi
40. ble or rigid must be rated for use with a high efficiency positive pressure vent system Corrosion resistant chimney liner systems are typically made from a high grade stainless steel such as AL29 4C The liner must be properly sized and fully sealed throughout the entire length Both the top and bottom of the masonry chimney must be capped and sealed to provide a dead air space around the liner A WARNING Do not vent this pool heater into a masonry chimney without a sealed stainless steel liner system Any breaks leaks or damage to the masonry flue tile will allow the positive pressure flue products to leak from the chimney and into occupied living spaces This could cause serious injury or death due to carbon monoxide poisoning and other harmful flue products IMPORTANT Check with local code officials to determine code requirements or the advisability of using a masonry chimney with a sealed corrosion resistant liner system Sidewall Vent Termination Clearances and Location Follow all sidewall venting termination information for clearances and location under Sidewall Vent Termination Clearances and Location page 11 Commercial Pool Heaters INSTALLATION Continued TABLE E Sidewall Vent Kits Vent Termination Only 500 000 750 000 Btu hr N A Kit w Power Fan Assy Input Btu hr 500 000 SVK3006 100 ft 100 ft 650 000 SVK3008 750 000 SVK3008 100 ft 990 000 SVK3053 100 ft
41. bon monoxide poisoning and other harmful flue products IMPORTANT Check with local code officials to determine code requirements or the advisability of using a masonry chimney with a sealed corrosion resistant liner system Vertical DV Venting Termination You must use the vent termination recommended by the vent manufacturer for vertical direct vent terminations Follow all vertical venting termination information for clearances and location under Vertical Vent Termination Clearances and Location page 10 Horizontal DV Venting Termination Horizontal venting air inlet and flue outlet on the same wall uses the pool heater s internal combustion air blowers to force the flue products out of the horizontally terminated flue You must purchase a horizontal direct vent kit from the pool heater manufacturer to ensure proper operation See TABLE G this page to determine which horizontal direct vent kit you need When installing the vent cap the wall opening must provide an air space clearance of 2 inches 5 1cm around the flue pipe The diameter of the opening for installation of the sidewall cap will be 4 inches 10 2cm larger minimum than the nominal diameter of the installed vent pipe to the horizontal vent cap 22 Install the horizontal vent cap from the outside Mount the vent cap to the wall using four screws or wall anchors Seal under the screw heads with caulking Install the sealed AL29 4C vent pipe from the pool
42. ch per 4000 Btu hr input 5 5cm per kW You must locate this opening within 12 30cm ofthe bottom of the enclosure The ventilation air opening must have a minimum free area of one square inch per 4000 Btu hr input 5 5cm per kW You must locate this opening within 12 30cm of the top of the enclosure Figure 7 Outside Combustion Air Two Openings Installation and Service Manual Outside Combustion Air Using Ducts You can direct outside combustion air to this pool heater using two air ducts to deliver the air to the equipment room Each of the two openings must have a minimum free area of one square inch per 2000 Btu input 11cm i 9 Figure 8 Outside Combustion Air Through Ducts 3 Outside Combustion Air Using Direct Venting With this option you can connect combustion air vent piping directly to the pool heater See the information under Direct Venting starting on page 21 for specific information regarding this option Combustion Air from Interior Space You can direct combustion air to this pool heater using air from an adjoining interior space You must provide two openings from the equipment room to the adjoining room Each of the two openings must have a net free area of one square inch per 1000 Btu input 22cm per kW but not less than 100 square inches 645cm Figure 9 Combustion Air from Interior Space
43. cial location and clearance requirements See Outdoor Installation Venting page 25 A wind proof cabinet protects the pool heater from weather Clearances from Combustible Construction Maintain minimum specified clearances for adequate opera tion Allow sufficient space for servicing pipe connections pump and other auxiliary equipment as well as the pool heater See rating plate for specific service clearance require ments Right Side 3 7 5 cm Rear 3 7 5 cm 3 min from any surface Left Side 6 15cm 24 0 61m suggested for service Front Alcove 30 0 76m suggested for service Top 3 7 5cm Flue 1 25 4mm Hot Water Pipes 1 25 4mm An Alcove is a closet without a door Note No additional clearance is needed on the right side of the pool heater for the observation port An observation port is located on both the right and left side of the pool heater Note No additional clearances from combustibles are needed for use of the Direct Vent DV air inlet assembly 3 INCH MINIMUM FROM UNIT TO WALL Figure 2 Clearances from Combustible Construction Base for Combustible Floors There are no manufactured combustible floor base kits available for 990 000 2 070 000 Btu models See Table A for floor base kits that are available If a manufactured combustible floor base kit is not used you must construct a base for combustible floor installation Install the pool heater over a base of hollow c
44. completion of the post purge cycle the pool heater will go into an idle state whereby the temperature controller continuously monitors the water temperature until the water temperature drops to levels that require additional heat Commercial Pool Heaters WIRING BOX CONNECTIONS SENSOR CONNECTOR Outlet Inlet SensorSensor THs BL B 25 X2 18AWG BLBL 110 F REMOTE POOL HI LIMIT FIELD INSTALLED LWCO PROBE POOL RETURN SENSOR m x ONNECTIONS FOR PUMP M 20VAC FIELD 1 120 CONNECTIONS FOR UNIT WIRING BOX CONNECTIONS B WIRING BOX EACTOR CONNECTOR FLOW SWITCH AC POWER 2 2 CONNECTOR Ne SET 2 5 8 11 14 NC L RR 1 4 10 13 FLOW amp PRESS 3 4 G 8 BR T Ow TI Ww Y 4 A PP nes BR 1 2 all 01 NC C NO c E 4 MANUAL RESET 55 HI LIMIT zu 1 wo Eso o T PR BL gu E Li Y 2 rom B T W 2 A3 Big no i RY WwT PR O BK RL E PAX T 2990 HI LIMIT i SHUTOFF SOLENOID REMOVE FACTORY TEST OPTIONALE H VENTISOLENOID H H amp NORMALLY OPEN JUMPER WHEN INSTALLING Mur
45. e hot surface igniter Once this voltage has been sent to the valves the hot surface igniter is turned OFF The ignition module then monitors and proves the presence of the flame and will either allow operation to continue or shut down the gas valves should flame not be proven and proceed to a Flame Failure condition If flame was proven briefly during the ignition period the module may not proceed to Flame Failure but rather post purge and then go into another trial for ignition SOFT START MODELS 990 000 2 070 000 BTU HR ONLY Controlled by Temperature Controller A small time delay is provided to delay the opening of approximately half of the valves until the first half of the valves have opened and the gas has successfully ignited and established flame on the burners 53 HEAT TRANSFER PROCESS Gas Valves Burner and Heat Exchanger Once flame has been proven the ignition module will hold the gas valves open as long as there is proof of flame and a call for heat is present When the temperature of the water reaches that of the programmed set point the pool heater will be shut down POST PURGE Ignition Module Function When 24VAC is removed from the ignition module s thermostat input the module turns OFF the gas valves and maintains the blowers for approximately 25 seconds in order to allow the combustion chamber to be purged of all combustion by products IDLE Temperature Controller Function After
46. e that it is different than the temperature of the water coming from the pool By pressing the Select key again the Boiler Outlet Temperature is shown indicated by the text Boil Out This is the temperature of the water coming out of the pool heater before it is mixed with the water from the pool By pressing the key Select again the Boiler Rise is shown indicated by the text Boil AT This is the difference between the inlet and outlet temperatures at the pool heater If the pool supply sensor has been installed and connected by pressing the Select key the Pool Supply Temperature is shown indicated by the text SUP This will show the actual temperature of the water returning to the pool If in the Advance mode rear dip switch set to 0 position the Boiler On hours will be displayed indicated by the text BOIL ON in the display This is the total number of hours the pool heater has been heating the pool To clear the Boiler On hours press the Up and Down Arrow keys simultaneously For a detailed explanation of the advance settings see Appendix B on page 59 of this manual By pressing the Select key again the display returns to the Pool Temperature display Programming Mode In order to adjust any of the settings it is necessary to enter the Adjust mode This is done by pressing all three buttons simultaneously for one second and it will change from View to Adjust The setting shown can be adjusted within it s acceptable
47. e to a flooded pool heater can be extensive and present numerous safety hazards Any appliance that has been under water must be replaced Lighting Instructions 1 STOP Read the safety information 2 Program the temperature control to the desired settings see Operating Temperature Control page 40 3 Loosen knurled screw at the bottom of control panel cover see Figure 41 4 Grasp the bottom of the control panel cover and pull out 5 Locate the ON OFF switch inside control area Switch is located to the left of the pull out control circuitry tray see Figure 42 6 Turn the power switch to the OFF position 7 This pool heater is equipped with an ignition device which automatically lights the burners Do not try to light the burners by hand A This pool heater does not have a pilot It is equipped with an ignition device which automatically lights the burner Do not try to light the burner by hand B BEFORE OPERATING smell around the pool heater area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle to the floor Figure 41 Control Panel Cover 38 Installation ON OFF SWITCH Figure 42 ON OFF Switch 8 Turn the manual gas cock clockwise to the OFF position 9 Wait five 5 minutes to clear out any gas If you smell gas STOP Follow What To Do If You Smell Gas in the safety information If you don t smell gas go on
48. ed Bypass Outdoor Operation Outdoor 3 Way Valve Cover Manual Operation of the 3 Way Valve Actuator Table of Contents Relief Valve Water Flow Switch Pump Purge Delay Option Service Indicator Option Connecting to Electrical Supply 3 Way Valve Wiring Terminal Strip Connection Options Operation Lighting Instructions To Turn Off Gas To Pool Heater Pre Start Checklist Starting the Filter System Operating Temperature Control Programming Mode Error Messages Temperature Control Hot Surface Ignition System Operation and Diagnostic Lights Water Chemistry Pipe Size Requirements Circulating Pump Minimum Pump Performance Heat Exchanger High Water Temperature Limit Control Cleaning and Maintenance Heat Exchanger Cleaning Combustion and Ventilation Air Adjusting Differential Air Pressure Set Up Procedure Adjustment Procedure Servicing Hot Surface Igniter and Ignition Module Ignition System Checkout Energy Saving Recommendations Sequence of Operation Glossary Wiring Box Connections Ladder Diagram Control Box Connections Appendix A_Unit Start Up Checklist Appendix B_Adjust Menu Settings for Operating Modes 59 Revision Notes Back Cover Installation and Service Manual GENERAL PRODUCT INFORMATION Special Instructions This manual supplies information for the installation operation and servicing of this pool heater Read and understand this manual completely before installing the pool heater Installation and service mu
49. ed at 130 reference pages 33 34 and 46 of this manual to ensure that the pipe size and piping arrangements are correct If problems arise during the start up reference the Installation and Service Manual and or consult the factory Installation and Service Manual Appendix B Adjust Menu Settings for Operating Modes User advanced mem Description Defaut Range X BOILINMIN Minimuminletwater temperature 130F 130to150F __ X BOIL Maximum outlet temperature 200 F 120 0200 SUPTARGET Supply water temperature 100 _ OFF 70 to 110 F SUPDIFF Differential setting for supply 20 F 2 to 20 F MOTOR SPHED Setting other than 20 may void warranty __ 20sec I5to30sec _ PX DLY Time at which purging stops_ a en C or F User Settings Rear dip switch set to 1 position Advanced Settings Rear dip switch set to 0 position If equipped with optional pool supply sensor View Menu information BOIL ON Advanced switch set to 0 Advanced settings By pressing the Select key in the View mode while viewing the Boiler AT reading or the Supply Sensor temperature if the Pool Supply sensor is connected the Boiler On hours will be displayed indicated by the text BOIL ON in the display This is the total number of hours the pool heater has been heating the pool By pressing the Select
50. encer Remote Aquastat terminals located within the electrical wiring box Two types of connections are offered Continuous terminals provide for connection of safety devices that are desired to be constantly monitored Intermittent terminals are provided for devices that are only monitored during a call for heat cycle Connection to either of these terminals requires the removal of a factory installed jumper located on the terminal strip TEMPERATURE CONTROLLER Operator A single stage temperature controller is provided on the pool heater and it serves to maintain a user selectable temperature set point In addition to maintaining a set point it can provide for desired differential setting Ultimately the temperature controller delivers 24VAC to the ignition module and pressure switch when it senses heat mode is desired IGNITION MODULE Controlled by Temperature Controller One ignition module is provided on the pool heater Upon sensing the 24VAC delivered to it by the temperature controller the ignition module checks for a shorted pressure switch and then provided the air switch isn t shorted supplies 120VAC to its blower output relay and waits for a pressure switch signal BLOWERS Controlled by Ignition Module and Relay Board Two blowers serve to provide combustion air to the pool heater Both blowers operate in tandem anytime the ignition module is given a call for heat signal PRESSURE SWITCH Activated by Blow
51. er Turning On One pressure switch is provided to monitor its On Off operation Upon a call for heat 24VAC is delivered to the pressure switch If the blower generates adequate air pressure the pressure switch closes to deliver 24VAC to the ignition module s pressure switch monitoring input terminal Installation and Service Manual PREPURGE Ignition Module Function Once the ignition module sees a 24VAC input from its pressure switch it runs the blowers for approximately 15 seconds in order to purge the combustion chamber of any unburned fuel air mixture IGNITER WARM UP AND PROVING Ignition Module Function Once the ignition module has completed its prepurge period it turns on the hot surface igniter Once the hot surface igniter s current draw reaches a proper level the ignition module begins an additional period of approximately 25 seconds for the igniter to ensure the ignition temperature is attained to ignite the fuel air mixture IGNITER Controlled by Ignition Module One igniter is provided in order to ignite the fuel air mixture and its operation and timings are controlled by the ignition module IGNITION AND FLAME PROVING Ignition Module Function Once the warm up and proving period has been completed the ignition module sends 24VAC to the gas valves on approximately half of the pool heater These gas valves should open and allow gas to flow to the burners The fuel air mixture should ignite from th
52. er image and images on pages 5 33 35 amp 40 to illustrate the change in CPVC Pool Loops Revision 14 ECO C06951 reflects the correction of description and temperatures regarding the high temperature limit control on page 46 A note was added to Table E on page 20 and Table F on page 21 that barometric dampers are only included in kits for 990 000 to 2 070 000 models CPE I S 14 CP 5M 12 10
53. ers Combustion Air Inlet Piping WARNING Locate and install the combustion air inlet cap correctly Failure to do so can allow the discharge of flue products to be drawn into the combustion process This can result in incomplete combustion and potentially hazardous levels of carbon monoxide in the flue products This will cause operational problems and the spillage of flue products Spillage of flue products can cause personal injury or death due to carbon monoxide poisoning The sidewall or vertical rooftop DirectAire combustion air supply system has specific vent material and installation requirements The air inlet pipe connects directly to the pool heater to supply combustion air In most installations the combustion air inlet pipe will be a dedicated system with one air inlet pipe per pool heater You can combine multiple air inlets if the guidelines in Combined Air Inlet Points page 13 are followed The air inlet pipe will be connected to a combustion air inlet cap as specified in this section For normal installations this system uses a single wall pipe to supply combustion air from outdoors directly to the pool heater Where overnight temperatures reach 40 F use a Type B double wall vent pipe or an insulated single wall pipe for combustion air This will help prevent moisture in the cool incoming air from condensing and leaking from the inlet pipe Note When the use of the DV box adapter in the following vent
54. et the point of termination for the combustion air inlet cap must be at least 3 feet 0 91m below the point of flue gas termination vent cap Do not install the combustion air inlet cap closer than 10 feet 3 05m from an inside corner of an L shaped structure Horizontal Combustion Air Inlet Clearances You must locate the horizontal air inlet termination point at least 12 30cm above grade and above normal snow levels If the air inlet cap is within a 10 foot 3 05m radius of the flue outlet the point of termination for the combustion air inlet cap must be at least 3 feet 0 91m horizontally and 12 inches 30cm below the point of flue gas termination vent cap Do not install the horizontal combustion air inlet cap above the flue outlet Do not install the combustion air inlet cap closer than 10 feet 3 05m from an inside corner of an L shaped structure Multiple Sidewall Direct Vent Installations The combustion air inlet caps for multiple pool heater installations must maintain the same minimum clearance from the closest flue vent cap as specified in single pool heater installations You may install multiple flue outlet caps side by side and multiple combustion air inlet caps side by side but the air inlet must always be at least 3 feet 0 91m horizontally and 12 inches 30cm below the closest flue outlet Do not install combustion air inlet caps above the flue outlets Maintain all clearances and installation require
55. fault is a flame failure condition An ignition module that is in a hard lockout condition may only CAUTION The igniter is extremely fragile be reset by pushing the reset button for the ignition control very careful when removing A faulty or damaged hot The reset button is located on the front of the control panel surface igniter MUST BE replaced with a Lochinvar Upon a flame failure the reset button is only active after the PLT3400 igniter DO NOT use general purpose field control module has completed its post purge cycle Turning replacement igniters main power OFF and then ON or cycling the thermostat will not reset a hard lockout condition Wait five seconds after turning on the main power before pushing the reset button when the ignition module is in a hard lockout The ignition module will go into a soft lockout in conditions of low air low voltage or low hot surface igniter current A soft lockout condition will operate the combustion air fans for the post purge cycle and then the ignition module will pause for approximately five minutes At the end of this timed pause the ignition module will attempt a new trial f for ignition sequence If the soft lockout fault condition has subsided or has been corrected at the end of the timed pause main burner ignition should be achieved with the resumption of the normal trial for ignition sequence If the control sensed fault is not
56. g controls Wiring errors can cause improper and dangerous operation Appliance Area Keep appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids Water Circulating Pump Inspect the pump every six months and oil as necessary Use SAE 30 non detergent oil or lubricant specified by the pump manufacturer Burner Flames Visually check the main burner flames at each start up after long shutdown periods or at least every six months Burner view ports are located on the right and left sides of the pool heater WARNING The areas around the burner view ports are hot Direct contact with the pool heater could result in burns Normal Flame Yellow Tips Yellow Flames Lifting Flames Figure 51 Flame Pattern Illustration 47 Normal Flame A normal flame is blue with slight yellow tips has a well defined inner cone and displays no lifting flames Yellow Tips The usual causes for yellow tips on the burner flame are burner air flow blockage or partial obstruction Yellow Flames The usual causes for yellow flames are primary air flow blockage to the burner s or excessive gas input Correct this condition immediately Lifting Flames The usual causes for lifting flames are over firing the burner s excessive primary air or high draft If you observe improper flame patterns examine the venting system ensure
57. hat are shut down or will not operate may experience freezing due to convective airflow in the air inlet pipe Length of Air Inlet Pipe The installed length of air inlet pipe from the pool heater to the outside air inlet cap must not exceed 50 equivalent feet 15 2m Subtract 5 feet 1 5m of equivalent length for each 90 elbow Subtract 2 5 feet 0 7m of equivalent length for each 45 elbow Do not exceed the limits for the combustion air inlet piping lengths Connecting the Air Inlet Pipe to the Pool Heater Connect the air inlet piping directly to the pool heater by attaching it to the DV box adapter The DV box adapter is included in the direct vent kits for horizontal direct vent For vertical direct vent order the DVK3003 kit from the pool heater manufacturer The combustion air inlet area of the pool heater is located at the right rear corner of the pool heater This pool heater uses a simple air filter to ensure clean air is used for the combustion process Attach the DV box adapter over the air filter see Figure 24 Align the screw holes on the DV box adapter with the screw holes surrounding the air filter hanger Insert the sheet metal screws and tighten firmly Figure 24 Attaching DV Box Adapter to Unit For venting versatility you can move the air filter assembly and DV box adapter to the right side of the pool heater Remove the metal panel on the pool heater s right side see Figure 25 Remove the fi
58. he switch The left pressure tapping connection on the manometer connects to the tee in the tubing from the pool heater front chamber and the right pressure tapping connection on the manometer connects to the tee in the small tubing from the burner Commercial Pool Heaters CLEANING AND MAINTENANCE Continued If the air pressure switch does not make within 60 seconds from the time the fans turn ON the ignition module will go into a soft lockout period approximately 5 minutes in duration during which time the fans are turned off and the module shows the Low Air flash code If necessary soft lockout can be circumvented by cycling power using the ON OFF switch to cycle power to the unit Note If the pool heater has been firing recently allow the pool heater to cool for five minutes with the fans running before beginning the adjustment procedure Retain the plastic caps removed from the tees for reinstallation when complete Adjustment Procedure 1 4 Remove the upper front jacket panels from the unit to access the upper chamber Slightly loosen screws that attach fan transition box to metal base see Figure 53 Depending on model the air shutter s may be located either on the side or the rear of the fan duct Locate the air shutter at the side rear of the fan duct see Figure 52 and 54 Move the air shutter towards the rear or left side of the unit to increase air pressure Move the air shutter towards the fr
59. her appliances remaining connected to the common venting system are not in operation l 2 Seal any unused opening in the common venting system Visually inspect the venting system for proper size and horizontal pitch Make sure there is no blockage or restriction leakage corrosion and other unsafe conditions If possible close all building doors and windows Close all doors between the space in which the appliances remaining connected to the common venting system are located and other building spaces Turn on clothes dryers and any other appliances not connected to the common venting system Turn on any exhaust fans such as range hoods and bathroom exhausts so they will operate at maximum speed Do not operate a summer exhaust fan 5 Close fireplace dampers 15 Place in operation the unit being inspected Follow the lighting instructions Adjust thermostat so pool heater will operate continuously Test for spillage of flue gases at the draft hood relief openings of all appliances connected to the venting system after five minutes of main burner operation After making sure that each appliance remaining connected to the common venting system properly vents when tested as above return doors windows exhaust fans fireplace dampers and other gas burning appliances to their previous conditions of use Correct any improper operation of the common venting system so that the installation conforms
60. his error cannot be field repaired Replace the pool heater s temperature control if the error persists SHr There is a short in the temperature sensor Make sure sensors are properly installed wired and connected to the control Correct sensor installation or replace sensor OPn There is a break in the wiring to the temperature sensor Make sure sensors are properly installed wired and connected to the control Correct sensor installation or replace sensor FP The burner is not running 2 minutes after the start of the call for heat Check ignition control codes E02 The outlet temperature from the pool heater reached its maximum setting Check the bypass pump and mixing valve E03 The inlet temperature into the pool heater was below its target temperature for more than 15 minutes Check the mixing valve Commercial Pool Heaters OPERATION Continued Hot Surface Ignition Control Module Ignition Module Lockout Functions HOT SURFACE IGNITION SYSTEM The ignition module may lockout in either a hard lockout condition requiring pushing of the reset button to recycle Hot Surface Igniter and Ignition Control the control or a soft lockout condition which may recycle Module after an approximate five minute waiting period This soft lockout condition is intended to allow self correcting faults This unit has one ignition module and one hot surface igniter to correct themselves and permit normal operation A typical hard lockout
61. ial Pool Heaters GLOSSARY POWER SUPPLY 120VAC 60Hz 1PH power connects to black line and white neutral wires located within an electrical wiring box located on the left side of the pool heater A green chassis grounding wire is also provided for connection to earth ground ON OFF ROCKER SWITCH The black line voltage wire runs directly to a single pole single throw On Off rocker switch located behind the front cover accessible by a knurled knob Turning ON the rocker switch delivers line voltage to the low voltage transformer and ignition module Note The On Off switch does not provide for disconnection of power being supplied to any remotely connected devices that may be connected to the pool heater i e pumps louvers power venters etc As such it may be necessary to locate and turn OFF power to these items before attempting to service the pool heater LOW VOLTAGE SUPPLY TRANSFORMER A 120VAC to 24VAC transformer located within the control panel provides 24VAC 60Hz to many of the components located on the pool heater One of its 24VAC outputs blue is connected to a circuit breaker and the other yellow is connected to chassis ground 24VAC CIRCUIT BREAKER A circuit breaker is provided for protection of the low voltage supply transformer from overloads and short circuits The breaker is located inside the pool heater on the right rear of the control panel Power from this breaker goes to the temperature control
62. ic bypass valve Install the end caps JKD6653 and JKD6654 using the four screws provided in the kit BLT7901 as shown in Figure 32 11 Turn the power on to the unit and resume operation Note The actuator handle is not used when the outdoor cover is installed The handle is attached to the underside of the actuator for storage END CAP JKD6653 VA COVER CONDUIT FITTING Figure 32 3 Way Valve Cover Manual Operation of the 3 Way Automatic Bypass Valve Actuator To manually operate the 3 way automatic bypass valve actuator 1 Power must be removed from the unit 2 Once power is removed the de clutch button located on the side of the valve actuator body can be pressed CAUTION Failure to remove power from the actuator prior to attempting to manually operate the valve can result in irreparable damage to the actuator mechanism PLASTIC ACTUATOR VALVE COVER JKD6652 END CAP JKD6654 E NOTE REFER TO THE NUMBERS LOCATED NEXT TO THE TERMINALS WHEN MAKING WIRING CONNECTIONS 3 WAY VALVE CIRCUIT BOARD Figure 33 3 Way Valve Cover Connection Diagram 32 Installation and Service Manual MODEL NO BYPASS PIPE SIZE CP N L 501 751 2 MINIMUM CP N L 991 2071 2 1 2 MINIMUM r AUTOMATIC BYPASS VALVE FACTORY POOL RETURN SENSOR LOCATION PVC MINIMUM SEE TABLE RECOMMENDED ISOLATION VALVE FROM FILTER
63. ic gauge Range of scale should be 14 w c or greater to check inlet pressure Turn on gas supply at the manual gas cock turn on L P gas at the tank if required Turn the power switch to the ON position Turn the gas valve knobs to the ON position Set the temperature control to call for heat See Operating Temperature Control on page 40 for programming instructions Observe the gas supply pressure as all burners are firing Ensure that inlet pressure is within the specified range See Connecting To Gas Supply page 26 for minimum and maximum gas supply pressures If gas pressure is out of range contact gas utility gas supplier qualified installer or service agency to determine necessary steps to provide proper gas pressure to the pool heater 10 If gas supply pressure is within normal range turn the power switch to the OFF position 11 Turn gas valve knobs to the OFF position 12 Shut off gas supply at the manual gas cock in the gas piping to the pool heater If fuel supply is L P gas shut off gas supply at the tank 28 Installation and Service Manual 13 Remove the manometer and related fitting from the inlet side of the gas valve replace 1 8 hex plug in the gas valve and tighten 14 Turn on the gas supply at the manual valve turn on L P gas at the tank if required 15 Turn the power switch to the ON position 16 Turn the gas valve knob
64. in a tee or collar installed in the vertical pipe rising from the pool heater s flue outlet The barometric damper MUST NOT be installed in a bull head tee installed on the pool heater s flue outlet The tee or collar containing the barometric damper should be approximately three feet vertically above the connection to the pool heater s flue outlet This location ensures that any positive velocity pressure from the pool heater s internal combustion fan is dissipated and the flue products are rising due to buoyancy generated from the temperature of the flue products Adjust weights on the damper to ensure that draft is maintained within the specified range 1 Conventional Negative Draft Venting IMPORTANT Before installing the venting system follow all venting clearances and requirements found in the Venting General Information section page 10 Figure 17 Conventional Negative Draft Vertical Venting with Combustion Air Louvers This option uses Type B doublewall flue outlet piping The blower brings in combustion air The buoyancy of the heated flue products cause them to rise up through the flue pipe The flue outlet terminates at the rooftop Negative Draft The negative draft in a conventional vent installation must be within the range of 0 02 to 0 08 inches w c to ensure proper operation Make all draft readings while the pool heater is in stable operation approximately 2 to 5 minutes Installation a
65. ing systems is not practical contact the manufacturer for an in line filter to address problems Length of Air Inlet Pipe The installed length of air inlet pipe from the pool heater to the outside air inlet cap must not exceed 50 equivalent feet 15 2m Upsizing air inlet pipe diameters is permitted to meet increased length requirements Subtract 5 feet 1 5m of equivalent length for each 90 elbow Subtract 2 5 feet 0 7m of equivalent length for each 45 elbow Do not exceed the limits for the combustion air inlet piping lengths Sidewall Air Inlet The sidewall air inlet cap is supplied in the Horizontal DirectAire Vent Kit Order the kit from the appliance manufacturer This sidewall cap supplies combustion air for a single pool heater only See TABLE D page 17 for kit numbers Locate the pool heater as close as possible to the sidewall where you will install the combustion air supply system TABLE C Minimum Recommended Combustion Air Supply to Equipment Room Combustion Air Source Boiler Input Outside Air 2 Openings Outside Air 1 Opening 500 000 125 in 806 cm 167 in 1 077 cm 650 000 163 in 1 052 cm 750 000 188 in 1 213 cm 990 000 248 in 1 600cm2 Inside Air 2 Openings 500 in 3 226 cm 217 in 1 400 650 in 4 194 cm 250 in 1 613 cm 750 in 4 839 cm 330 in 2 129 cm 990 in 6 388 cm 1260 in 8 130 cm 1440 in 9 291 cm 1800 in 11 6
66. ipe IMPORTANT For every elbow and tee in excess of those shown above deduct 5 feet from the maximum allowable straight pipe in the pool heater to the system circulating loop TABLE R Minimum Pump Performance o 46 Minimum Pump Performance Pump performance is based on providing adequate flow and temperature rise to prevent scale accumulation in the heat exchanger See Water Chemistry on page 44 Heat Exchanger This is a highly sophisticated heat exchanger designed to carry water in such a way that it generates a scouring action which keeps all interior surfaces free from build up of impurities The straight line two pass design of the tubes sends water into the headers at a properly rated velocity The configuration of the headers in turn creates a high degree of turbulence which is sufficient to keep all contaminants in suspension This scouring action provides greater cost savings for owners Tubes are always able to transfer heat at peak efficiency Every surface within this water containing section is of a non ferrous material providing clear clean rust free water Straight copper tubes finned on the outside for maximum heat transfer coated cast iron one piece cored headers make up an entirely rust proof pool heater A Cupro Nickel heat exchanger is standard on 1 800 000 2 070 000 Btu hr models On all models header inspection plugs can be removed for field inspection and cleaning of copper tubes The ent
67. iple pool heater air inlets must be provided with an exterior opening which has a free area equal to or greater than the total area of all air inlet pipes connected to the common air inlet This exterior opening for combustion air must connect directly to the outdoors The total length of the combined air inlet pipe must not exceed a maximum of 50 15 2m equivalent feet You must deduct the restriction in area provided by any screens grills or louvers installed in the common air inlet openings and some rooftop terminations Screens grills or louvers installed in the common air inlet can reduce the free area of the opening from 25 to 7596 based on the materials used Vertical and Sidewall Combustion Air Inlet IMPORTANT To prevent recirculation of flue products into the combustion air inlet follow all instructions in this section AN WARNING Locate and install the combustion air inlet termination correctly Failure to do so can allow the discharge of flue products to be drawn into the combustion process This can result in incomplete combustion and potentially hazardous levels of carbon monoxide in the flue products This will cause operational problems and the spillage of flue products Spillage of flue products can cause personal injury or death due to carbon monoxide poisoning You must locate the combustion air cap and the flue gas outlet on the same rooftop surface vertical direct vent system or sidewall surface h
68. ire heat exchanger may be easily removed from the pool heater WARNING Should overheating occur or the gas supply fail to shut off do not turn off or disconnect the electrical supply to the pump Instead shut off the gas supply at a location external to the pool heater High Water Temperature Limit Control This pool heater is equipped with an auto reset auxiliary mixed water limit control that is to be installed in the filter system piping This temperature limit control has a maximum limit setting of 110 F 43 C It is also equipped with an adjustable setting manual reset high water temperature limit control This temperature limit control has a maximum limit setting of 200 F 93 C for 500 000 75 000 Btu models and 210 F 99 C for 990 000 2 070 000 Btu models If water temperature exceeds the set point the limits will break the control circuit and shut down the pool heater The auto reset auxiliary mixed water limit control can only be reset after the water temperature has cooled below the set point of the limit The manual reset limit control will require an operator to push the reset button located immediately below the high limit dial if this limit has tripped Installation and Service Manual CLEANING AND MAINTENANCE Listed below are items that must be checked to ensure safe reliable operations Verify proper operation after servicing AN CAUTION Label all wires prior to disconnection when servicin
69. l heater may shut down and recycle when the regulator cover screw is removed This is normal 13 Turn the regulator adjustment screw clockwise to raise the regulator gas pressure Turn the regulator adjustment screw counterclockwise to lower the regulator gas pressure 14 Replace the regulator cover screw and make sure it is tight for proper operation 15 Read the value on the manometer magnahelic and compare it to the values in TABLE L 16 Repeat this adjustment procedure for each gas valve as necessary to adjust to the proper manifold gas pressure 17 Remove hoses replace and tighten plugs and caps when complete 18 Replace top front upper jacket access panels and control panel door in reverse order 19 If proper ignition and burner operation is not achieved after checking gas supply pressure see Cleaning and Maintenance page 49 for Combustion Air Fan Adjustment Follow the procedure to adjust the combustion air fans as necessary Installation and Service Manual TABLE L Net Manifold Pressure 500 000 750 000 Natural Gas Net Manifold Pressure equals the measured manifold pressure minus the chamber pressure See Figure 31 to measure the Net Manifold Pressure POOL HEATER PIPING INSTALLATION Install piping from the filter system to the pool heater as shown in the pool heater piping diagrams See Figures 34 38 Minimum pipe diameter to and from the installed pool heater to the filter system pi
70. lame Establishing Period 4 Seconds Failure Response Time 0 8 Seconds at less than 0 5 pA flame current Flame Current 5 15 pA Post purge 30 Seconds Optional Pump Delay Timing 30 Seconds after burner shutdown Commercial Pool Heaters OPERATION Continued Water Chemistry OPERATION AND DIAGNOSTIC pud which affect pool water and more importantly the efficiency of your new pool heater are INDICATORS 1 Proper Filtration The control panel has up to six indicating and diagnostic lights to 2 Proper Circulation show all major steps of operation and control sensed malfunctions 3 Disinfection and Oxidation There are display indicators on the Operating Temperature Control 4 pH Control and Total Alkalinity that give status information as well 5 Algae Control 6 Water Balance CAUTION Salt levels above 5000 ppm can cause corrosion damage to heat exchangers The water chemistry of your pool changes daily due to natural evaporation of the water and the addition of chemicals Chemicals are used to sanitize and control algae growth in the pool Their addition must be carefully monitored The accumulation of minerals or scale in the pool heater due to a chemical imbalance will cause a non warrantable failure of the heat exchanger and its components pH is an important factor in maintaining proper balance in your pool water pH is the measurement of the acidity or alkalinity of water The following chart shows the recommended
71. lay tiles or concrete blocks from 8 to 12 thick extending at least 24 beyond the pool heater sides Place tiles or blocks so that the holes line up horizontally to provide a clear passage through the tiles or blocks Place a 1 2 fireproof millboard over the top of the tile or block base Place a 20 gauge sheet metal cover over the fireproof millboard Center the pool heater on the base Also follow this procedure if electrical conduit runs through the floor beneath the pool heater This base must meet all local fire and safety codes Installation and Service Manual TABLE Combustible Floor Kits Input Btu hr Kit Number 500 000 CFK3302 650 000 CFK3303 750 000 CFK3304 FREEZE PROTECTION Although this pool heater is CSA design certified for outdoor installations such installations are not recommended in areas where the pool heater will be operated in the winter months and the danger of freezing exists Proper freeze protection must be provided for outdoor installations pool heaters installed in unheated equipment rooms or where temperatures may drop to the freezing point or lower If freeze protection is not provided for the system a low ambient temperature alarm is recommended for the equipment room Damage to the pool heater by freezing is non warrantable 1 Pump Operation MOST IMPORTANT This pool heater is designed for continuous operation of the filter system pump when the burners are firing If the system pump doe
72. ler ignition module and various other components and or options on the pool heater When tripped all factory installed 24VAC components will lose their 24VAC power MANUAL RESET HIGH LIMIT THERMOSTAT A manual reset high limit thermostat is provided as backup for the auto reset high limit This is an adjustable dial bulb capillary style thermostat that will trip and require resetting should water temperature exceed its settings When tripped all controls remain powered but 24VAC is prevented from being delivered to the ignition module s thermostat input EMS SEQUENCER REMOTE AQUASTAT TERMINALS The EMS sequencer remote aquastat terminals are provided for connection of the pool heater to an external energy management system or sequencer and are located along the top edge of the terminal strip located within the electrical wiring box In addition to providing a means to externally fire the pool heater these terminals also provide for remote shutdown by routing through dry contacts from external devices Connection of the external dry contacts to these terminals requires the removal of one or more factory installed jumpers located on the terminal strip 52 SAFETY DEVICE TERMINALS The safety device terminals ensure that no power can be delivered to the ignition module unless factory field installed safety devices such as flow switches and gas pressure switches are closed These safety device terminals are located below the EMS Sequ
73. lies gas to the orifice inlet to pre mix The gas air mixture is forced into the burner and out of the burner ports under pressure The hot surface igniter lights the gas air mixture and then serves as a flame sensor to prove main burner flame by rectification Burners for all stages are now firing at rated input on the 500 000 through 750 000 Btu hr models On the 990 000 through 2 070 000 Btu hr models approximately 5096 of the input is now energized 24V AC is supplied to a digital temperature control which times out and then energizes the next 5096 of the gas valves The remaining gas valves open and supply gas to the orifice inlet to pre mix The gas air mixture is forced out of the burner ports and light by carry over from the burners currently firing The heater is now firing at full rated input HEAT TRANSFER PROCESS 26 27 28 Heated products of combustion pass over the heat exchanger transferring heat to the water The rate of flue product movement is controlled by V baffles on the heat exchanger to maximize heat transfer Flue products pass into the flue collector and are exhausted from the unit END OF SEQUENCE 29 30 31 32 Set point temperature for the pool water is satisfied Power to the gas valves is turned OFF The combustion air fan runs for a 30 second post purge timing and turns OFF The unit is now in a Standby Mode waiting for the next Call for Heat Commerc
74. low the steps below to adjust the fan if a continuous Low Air status code occurs Note On the 500 000 750 000 Btu hr models the air shutter is adjusted on the side of the fan duct as depicted in Figure 52 On the 990 000 2 070 000 Btu hr models the air shutter is adjusted on the rear of the fan duct as depicted in Figure 54 1 Check for proper installation and draft in the venting system Correct as required 2 The following pressure settings are for installations up to 4000 feet altitude Contact the factory for high altitude air pressure settings Adjusting Differential Air Pressure The following is a recommended method for setting the differential air pressure AP for each fan Figure 52 Adjusting Air Shutter 500 000 750 000 Btu hr 49 lt gt gt S ms L7 E LBS XY AIR SHUTTER Figure 54 Adjusting Air Shutter 990 000 2 070 000 Btu hr Models Set Up Procedure Beside the fan duct is an air pressure switch with a large and a small tube delivering pressure from points inside the pool heater see Figure 55 The pressure in the large tube is the chamber pressure The pressure in the small tube is the burner pressure They act together to make the pressure switch By disconnecting the caps from the tees in the pressure switch hoses and connecting them to either side of a manometer you can read the differential pressure to t
75. lter bracket assembly from the rear of the pool heater Note Modifications to the DV box adapter will be necessary to allow installation on the right side of the pool heater Follow the instructions shipped with the vent kit 23 Attach the filter bracket assembly and DV box adapter to the right side opening using the pre drilled screw holes Make sure you attach the metal panel to the rear combustion air opening of the pool heater The DV box adapter has an air inlet pipe mounting ring Connect combustion air inlet piping to the direct vent box mounting ring Figure 25 Moving Air Filter Assembly and DV Box Adapter Air Inlet Piping Materials The air inlet pipe s must be sealed Select the air inlet pipe material from the following specified materials PVC CPVC or ABS 6 7 or 8 LD Galvanized steel vent pipe with joints and seams sealed as specified below doublewall vent with joints and seams sealed as specified below Check local codes for possible restrictions WARNING Use only vent or air intake materials specified in this manual Follow vent pipe manufacturer s instructions Failure to do so can result in property damage personal injury or death Mixing of venting materials will void the warranty and certification of this pool heater Sealing Type B Doublewall Vent Pipe or Galvanized Vent Pipe Follow the steps below to properly seal Type B doublewall vent pipe or galva
76. lude a DV box adapter and a rooftop air inlet cap See note on page 12 concerning DV box adapter 3 Sidewall Venting IMPORTANT Before installing a venting system follow all venting clearances and requirements found in the Venting General Information section page 10 This option uses a powered vent assembly which pulls the flue products out of the stack This fan generates a negative draft at the pool heater Combustion air is drawn from the equipment room see Combustion and Ventilation Air page 7 Figure 21 Sidewall Venting Installation with an Induced Draft Fan and Sidewall Vent Cap Commercial Pool Heaters INSTALLATION Continued Sidewall Fan The sidewall fan can be mounted on the inside outside depending upon model with a sidewall vent hood installed on the exterior wall The sidewall fan and accessories are included in a venting kit provided by the appliance manufacturer See TABLE E for kit numbers The venting kit includes the sidewall fan vent hood tapered vent adapter barometric damper proving switch and all necessary relays to interlock with the heaters control system The tapered vent adapter reduces the vent size at the inlet to the fan There should be no reduction in vent diameter from the pool heater s flue outlet to the sidewall fan The barometric damper must be installed on the flue and adjusted to supply a negative draft within the range of 0
77. material and installation requirements The air inlet pipe connects directly to the pool heater to supply combustion air The combustion air inlet pipe is a dedicated system with one air inlet pipe per pool heater You must connect the air inlet pipe to a combustion air inlet cap as specified in this section su Figure 23A Horizontal DirectAire Installation Illustration with Sidewall Venter and Sidewall Combustion Air Combustion air supplied from outdoors must be free of contaminants see Combustion and Ventilation Air page 7 Vent Kits You must order the Horizontal DirectAire Vent Kit for sidewall installation See TABLE F for kit numbers Each kit includes a sidewall powered vent cap proving switch controls combustion air inlet cap to supply air to a single pool heater the transition adapter to attach the field supplied single wall air inlet pipe to the pool heater and installation instructions Purchase flue pipe and air inlet pipe locally The sidewall air inlet cap supplied in the Horizontal DirectAire Vent Kit is used to supply combustion air to a single pool heater Combustion air supply pipes from multiple pool heaters can not be combined into a single air inlet pipe and inlet point WARNING Only use the sidewall air inlet cap recommended by the appliance manufacturer Using another sidewall air inlet cap may result in operati
78. ments for multiple pool heater installations 6 Outdoor Installation Venting IMPORTANT Before installing a venting system follow all venting clearances and requirements found in the Venting General Information section page 10 These pool heaters are self venting and can be used outdoors when installed with the optional outdoor cap This cap mounts directly to the top of the pool heater and covers the flue outlet and combustion air inlet openings No additional vent piping is required WARNING Only install outdoor models outdoors and only use the vent cap supplied by the pool heater manufacturer Personal injury or product damage may result if any other cap is used or if an outdoor model is used indoors Properly install all covers doors and jacket panels to ensure proper operation and to prevent a hazardous condition 25 Combustion air supply must be free of contaminants see Combustion and Ventilation Air page 7 To prevent recirculation of the flue products into the combustion air inlet follow all instructions in this section Outdoor Vent Air Inlet Location Keep venting areas free of obstructions Keep area clean and free of combustible and flammable materials Maintain a minimum clearance of 3 76mm to combustible surfaces and a minimum of 3 76mm clearance to the air inlet To avoid a blocked air inlet or blocked flue condition keep the outdoor cap air inlet flue outlet and drain slot clear of sno
79. must conform to the CAE C22 1 Canadian Electrical Code Part 1 and or local Electrical Codes 1 Use only Type T wire 63 F 35 C rise on all wiring between the pool heater and field installed devices 2 Enclose line voltage wire exterior to the pool heater in approved conduit or approved metal clad cable 3 The pump must run continuously when the pool heater is being fired 4 To avoid serious damage do not energize the pool heater until the system is filled with water 5 Provide the pool heater with the proper overload protection IMPORTANT Do not block access to the electrical cover plate when installing electrical conduit 3 Way Automatic Bypass Valve Wiring If the piping loop was disassembled for shipping or needs to be fitted with an outdoor enclosure connection or disconnection of the 3 way automatic bypass valve will be required Wiring connections should be made to the appropriately numbered terminals on the 3 way automatic bypass valve as follows Yellow to terminal 1 Blue to terminal 2 White with a red stripe to terminal 3 Pink to terminal 4 Note Orientation of the valve connections may vary from what is shown Care should be taken to ensure wires are connected to the appropriate terminals see Figure 33 on page 32 of this manual WARNING Power must be removed and the clutch button must be depressed before attempting to manually operate the valve or damage to the 3 way valve
80. n uses a powered vent assembly to exhaust the flue products out a sidewall vent termination Combustion air is supplied from the equipment room See page 17 for venting details Horizontal DirectAire Venting This option uses a powered vent assembly to exhaust the flue products out a sidewall Combustion air is supplied by a pipe from the sidewall See page 20 for venting details Direct Venting This option uses a sealed AL29 4C flue and a separate combustion air pipe to the outdoors This system terminates both the flue and combustion air inlet in the same pressure zone The flue outlet and combustion air intake may terminate at either a sidewall horizontal or the rooftop vertical See page 21 for venting details Outdoor Installation Venting This option uses the installation of a special air inlet vent cap on top of the pool heater See page 25 for venting details All pool heaters are shipped from the factory equipped for conventional negative draft venting All other optional vent systems require the installation of specific vent kits and venting materials The following is a detailed explanation of the installation requirements for each venting system components used and part numbers of vent kits for each model 14 Barometric Damper Location Any venting system option that requires a barometric damper must adhere to the following directions for optimum performance The preferred location for the barometric damper is
81. nd Service Manual Connect the flue vent directly to the flue outlet opening on the top of the pool heater No additional draft diverter or barometric damper is needed on single unit installations with a dedicated stack and a negative draft within the specified range of 0 02 to 0 08 inches w c If the draft in a dedicated stack for a single pool heater installation exceeds the maximum specified draft you must install a barometric damper to control draft Multiple pool heater installations with combined venting or common venting with other Category I negative draft appliances require each pool heater to have a barometric damper installed to regulate draft within the proper range Do Not connect vent connectors serving appliances vented by natural draft negative draft to any portion of a mechanical draft system operating under positive pressure Connecting to a positive pressure stack may cause flue products to be discharged into the living space causing serious health injury Flue Outlet Piping With this venting option you must use Type B doublewall or equivalent vent materials Vent materials must be listed by a nationally recognized test agency for use as vent materials Make the connections from the pool heater vent to the outside stack as direct as possible with no reduction in diameter Use the National Fuel Gas Code venting tables for doublewall vent to properly size all vent connectors and stacks Follow the vent manufacturer s
82. nd installation of the equipment is in accordance with the installation manual all local installation requirements and with the latest edition of the National Fuel Gas Code ANSI 223 1 and or CAN CGA B149 Installation Code 1 Measure the supply gas pressure For natural gas models the supply gas pressure should be between 4 5 w c to 10 5 w c For LP gas models the supply gas pressure should be between 8 w c to 13 w c For a detailed procedure on measuring the supply gas pressure reference page 28 of this manual Measure the differential air pressure The differential air pressure for the 500 000 750 000 Btu hr models should be between 1 5 w c to 1 65 w c The differential air pressure for 990 000 2 070 000 Btu hr models should be between 1 1 w c to 1 3 w c Reference pages 49 and 50 of this manual for the proper procedure for measuring the differential air pressure If an adjustment is necessary follow the procedure on page 50 of this manual Note The combustion air fan s is factory preset and should not need adjustment However due to installation and environmental conditions adjustment of the air fan shutter s may be necessary at start up 3 Measure the net manifold gas pressure For 500 000 750 000 Btu hr models the net manifold gas pressure for natural gas models should be 1 8 w c For LP gas models the net manifold gas pressure should be 4 6 w c For 990 000 2 070 000 Btu hr models the net manifold gas
83. nel Operation is based on temperature inputs from immersion sensors and if desired an external thermostat The temperature control will turn on and off based upon the temperature measured by the pool return sensor This sensor is factory installed in a bulbwell located in the inlet piping to the pool heater upstream of the 3 way automatic bypass valve The temperature control will turn on and off based upon an external thermostat connected between terminals R1 and W1 on the terminal board The temperature control will also turn off if the temperature measured by the pool heater output sensor exceeds a limit default 200 F or if the temperature measured by the optional pool supply sensor exceeds another limit default 100 F In addition the temperature control will operate a factory installed 3 way automatic bypass valve This is done to maintain a minimum temperature at the inlet to the pool heater default 130 F automatically protecting the pool heater from condensation of the 40 flue products If the boiler inlet temperature is not satisfied within 15 minutes the controller will shut the unit down To reset the unit press any key No manual valve adjustments are required An LCD is provided to display various readings and operating parameters Three 3 pushbuttons are available to change the display and to program parameters Figure 46 Figure 46 Temperature Control Display and Programming Keys
84. nized vent pipe 1 Seal all joints and seams of the air inlet pipe using either aluminum foil duct tape meeting UL Standard 723 or 181 A P or a high quality UL Listed silicon sealant such as those manufactured by Dow Corning or General Electric 2 On horizontal runs do not install vent pipe with seams pointing down Position vent pipe so that the seams are on the top side of the vent pipe Commercial Pool Heaters INSTALLATION Continued 3 Secure all joints with a minimum of three sheet metal screws or pop rivets Apply aluminum foil duct tape or silicone sealant to all screws or rivets installed in the vent pipe 4 Ensure that the air inlet pipes are properly supported WARNING Properly seal all joints and seams in the inlet vent piping system Failure to do so may result in flue gas recirculation spillage of flue products and carbon monoxide emissions Carbon monoxide poisoning can cause severe personal injury or death Combined Combustion Air Inlet Points You can combine the air inlet pipes from multiple pool heaters to a single common connection if the common air inlet pipe has a cross sectional area equal to or larger than the total area of all air inlet pipes connected to the common air inlet pipe Example Two 8 20 3cm air inlet pipes 50 3 in 324 5cm area each have a total area of 100 6 in 645 2cm requiring a 12 30 5cm 113 1 in 729 7cm common air inlet pipe The air inlet point for mult
85. nt freezing of pool heater water Provide Figure 12 Vent Termination from Flat Roof 10 or Less from Parapet Wall proper freeze protection See Freeze Protection page 7 TABLE NOTE NO HEIGHT Flue and Air Inlet Pipe Sizes ABOVE PARAPET REQUIRED WHEN Input Air Inlet 4 DISTANCE FROM Btu hr Size WALLS OR PARAPET WALLS OR CHIMNEY Figure 13 Vent Termination from Flat Roof More Than 10 750 000 ET GN from Parapet Wall 990 000 10 10 Sidewall Vent Termination Clearances 1 260 000 12 12 and Location 1 440 000 m 12 Locate the bottom of the vent terminal at least 12 inches 30cm above grade and above normal snow levels Locate the bottom of the vent terminal at least 7 feet 2 13m above grade 2 070 000 14 12 when located adjacent to public walkways Do not terminate 1 800 000 14 12 directly above a public walkway Minimum diameter for air inlet pipe Installer may increase diameter one pipe size for ease of installation if needed Refer to the National Do not terminate the venting system in a window well Fuel Gas Code ANSI Z223 1 Vent Tables for additional guidance on stairwell alcove courtyard or other recessed area Do not vent sizing of fan assisted appliances terminate the venting system below grade Locate vent termination at least 3 feet 0 91m from an inside corner of an L shaped structure 11 Commercial Pool Heat
86. nterconnection of the pool heater controls bypass pump and filter pump to ensure continuous circulation Proper venting Water chemistry Follow all clearances from combustibles contained in this manual Appliance surfaces become hot during operation Be careful not to touch hot surfaces Keep all adults children and animals away from an operating pool heater Severe burns can occur This pool heater must have an adequate supply of fresh air during operation for proper gas combustion and venting 10 Make sure all exhaust venting is properly installed and maintained Improper venting of this pool heater could lead to increased levels of carbon monoxide 11 Do not use this pool heater if any part has been under water Immediately call a qualified service technician to replace the pool heater The possible damage to a flooded pool heater can be extensive and present numerous safety hazards Any appliance that has been under water must be replaced 12 Do not alter this pool heater in any way Any change to this pool heater or its controls can be dangerous Installation and Service Manual PRODUCT IDENTIFICATION Figure 1B Optional Vertical Piping Loop Commercial Pool Heaters INSTALLATION This pool heater meets the safe lighting performance criteria with the gas manifold and control assembly provided as specified in the ANSI Z21 10 3 CSA 4 3 standard for gas fired water heate
87. o achieve proper ignition WARNING Do not have any open flame in proximity to the gas line when bleeding air from the 27 G gas line Gas may be present as Train and Controls Note The gas train and controls assembly provided on this pool he ater have been tested under the applicable American National Standard to meet minimum safety and performance criteria such as safe lighting combustion and safety shutdown operation Commercial Pool He INSTALLATION Continued Figure 29 shows a typical pool heater gas train COMBINATION VALVE e i TO BURNERS ADDITIONAL VALVES BASED ON UNIT INPUTS Figure 29 Typical Pool Heater Gas Train Drawing TABLE J Suggested Gas Pipe Size for Single Unit Installations Btu hr Distance From Meter in feet nie Combination Gas Valves These pool heaters fire in a single stage of operation Note This pool heater incorporates a soft start feature which lights approximately half of the burners before lighting the remaining burners Each combination valve consists of a gas regulator and two valve seats to meet the requirements for redundant gas valves The valve has a gas control knob that must remain in the open position at all times when the pool heater is in service The gas control valve has pressure taps located on the inlet and discharge sides of the valve Manifold pressure is adjusted
88. ocked flue condition Some discoloration to exterior building or pool heater surfaces can be expected Adjacent brick or masonry surfaces should be protected with a rust resistant sheet metal plate The Outdoor Vent Cap Kit The optional outdoor vent cap kit is available from the pool heater manufacturer The outdoor cap part numbers are listed by input size See TABLE H for kit numbers Install the outdoor vent cap on the rear of the pool heater see Figure 27 The air filter bracket will need to be rotated as shown in Figure 27 to allow proper access to the filters with the outdoor vent cap in place The 3 Way Valve Cover Insiallation The 3 way bypass valve requires a cover for outdoor use This cover is provided with the outdoor vent kits listed in Table H See page 31 for 3 way valve cover installation instructions Combustion Air Fan Adjustment for startup For startup the combustion air fan shutter may require adjustment Should the combustion air fan shutter need adjusting refer to the Adjusting Differential Air Pressure instructions located under the Cleaning and Maintenance section on page 49 of this manual Note The manifold gas pressure can affect the differential air pressure Once the combustion air fan shutter has been adjusted confirm manifold gas pressure as described in the Gas Manifold Pressure Adjustment section on page 30 of this manual 26 Figure 27 Outdoor Vent Cap Installed on Rear of Pool Hea
89. oducts can cause personal injury or death due to carbon monoxide poisoning For single pool heater installations with sidewall air inlet see Figure 18 you must order the sidewall air inlet kit The part number for each SVK kit is listed by input size in TABLE D For single pool heater installations with rooftop air inlet see Figure 20 you must order the rooftop air inlet kit The part number for each VDK kit is listed by input size in TABLE D Purchase the flue pipe rooftop flue termination and air inlet pipe locally There is no vent kit for combined air supply systems for multiple pool heaters Make sure the air inlet cap is properly sized You must purchase this cap locally Venting of Flue Products For venting flue products vertically to the outdoors follow all requirements in the installation instructions for conventional venting in this manual Follow all clearance requirements in Vertical Vent Termination Clearances and Location page 10 barometric damper is not required in the flue on Vertical DirectAire installations if the draft is within the negative 0 04 to 0 08 inches w c required for proper operation If the draft exceeds this range install a barometric damper 17 TABLE D DirectAire Kits Input Horizontal Vertical Btu hr Kit Kit 500 000 SVK3047 VDK3026 650 000 SVK3048 VDK3027 750 000 SVK3048 VDK3027 The SVK kits include a DV box adapter and sidewall air inlet cap The VDK kits inc
90. of the pool heater s indicating lights and a clear window to view the digital temperature display from the temperature control The thermostat and diagnostic light board are mounted to the back of the control panel door The control panel assembly is mounted on a slide out chassis to allow easy access to the components on the panel The control panel contains the ignition module transformer for the 24 VAC control circuit circuit breaker for the control circuit switching relays for component operation and wiring harness connections to the pool heater s components 43 The control panels are common and may be switched between pool heaters for troubleshooting Removing the Control Panel 1 Pull the control panel out as far as it will go 2 Remove the multi pin connector blocks from the top and right side of the control panel 3 Use 1 2 box wrench or socket wrench to remove the bolt on the right side of the control panel 4 Remove the entire control panel 5 Reinstall the control panel in the reverse order CAUTION Control panel is heavy and awkward to handle when removed Carefully support the control panel when removing Ignition and Control Timings Proven Pilot Hot Surface Ignition System F 9 on 500 000 through 2 070 000 Btu hr models with One Hot Surface Ignition Module Hot Surface Ignition Module Timings Nominal Prepurge 15 Seconds Hot Surface Igniter Heat up Time 25 35 seconds Main Burner F
91. ollowing safety rules 1 Pool heaters are heat producing appliances To avoid damage or injury do not store materials against the pool heater or the vent air intake system Use proper care to avoid unnecessary contact especially children with the pool heater and vent air intake components 2 Never cover your pool heater lean anything against it store trash or debris near it stand on it or in any way block the flow of fresh air to your pool heater 3 UNDER NO CIRCUMSTANCES must flammable materials such as gasoline or paint thinner be used or stored in the vicinity of this pool heater vent air intake system or any location from which fumes could reach the pool heater or vent air intake system 4 This pool heater is only for use with the type of gas indicated on the rating plate Commercial Pool Heaters 5 If you smell gas shut off the gas supply Do not try to light any appliance Do not touch any electrical switch do not use any telephone in your building Immediately call your gas supplier from a neighbor s telephone Follow the gas supplier s instructions Ifyou cannot reach your gas supplier call the fire department 6 This appliance is a high efficiency pool heater which has been designed to operate scale free and trouble free for many years Particular attention should be directed to the following items Correct piping to the pool filter system with specified pipe materials and size Electrical i
92. on the overlay This setting is used to control the responsiveness of the 3 way automatic bypass valve and should only be adjusted under the direction of Lochinvar s Technical Services personnel The default setting is 20 seconds By pressing the Select key again the pump Delay setting is displayed indicated by the DLY on the display This is the time that the heater pump will continue to run after the control turns the heater off The default value is 20 minutes amp Lochinvar High Efficiency Water Heaters Boilers and Pool Heaters Lochinvar Corporation 300 Maddox Simpson Pkwy Lebanon TN 37090 615 889 8900 Fax 615 547 1000 www Lochinvar com Revision Notes Hevision 6 CPE i amp s 06 reflects changes made to LBL2296 Revision 7 CPE i amp s 07 reflects changes made to the pressure switch page 50 Revision 8 CPE i amp s 08 reflects deletion of Table P and changes to associated paragraph on pages 44 amp 45 Revision 9 ECO C02822 reflects moving FIG 22A page 19 to page 21 and adding Aire Lock to the title Revision 10 ECO C03002 updated images to reflect the CPVC bypass pgs 1 5 33 35 and 40 along with updating the Ladder and Connection Box diagrams LBL20010 and 2001 1 Revision 11 ECO C04538 reflects the addition of salt levels on page 44 Revision 12 ECO C05507 reflects the correction of water flow direction FIG 37 and 38 Revision 13 ECO C06381 reflects the update of cov
93. onal problems and the spillage of flue products Spillage of flue products can cause personal injury or death due to carbon monoxide poisoning Venting of Flue Products Termination point for the flue products must follow the clearance requirements in Sidewall Vent Termination Clearances and Location page 11 For proper operation a barometric damper is provided for Horizontal DirectAire installations The damper will help to ensure a draft between negative 0 04 to 0 08 inches w c 20 Installation and Service Manual TABLE F Horizontal DirectAire Kits Input uem 2 070 000 HDK3039 These kits include a sidewall venter assembly vent termination DV box adapter sidewall air inlet cap and a barometric damper 990 000 2 070 000 Btu hr models only See note on page 12 concerning DV box adapter 5 Direct Venting IMPORTANT Before installing a venting system follow all venting clearances and requirements found in the Venting General Information section page 10 This option uses sealed AL29 4C vent materials for the flue outlet piping and separate combustion air inlet piping This system terminates both the flue and combustion air inlet in the same pressure zone The flue outlet and combustion air intake may terminate at either a sidewall or the rooftop To use the optional Direct Vent system you must install specific vent kits and venting materials The following is a detailed explanation of
94. ont or right side of the unit to decrease air pressure The 500 000 750 000 Btu hr models have one fan with a side mounted air shutter The differential for these models is nominally 1 5 1 65 inches water column 4b On the 990 000 2 070 000 Btu hr models adjust the air shutter 5 6 on the left fan until the differential pressure is nominally 1 1 1 3 inches water column Note The air chamber pressure is 1 2 inches water column for liquefied petroleum L P and 1 4 inches water column for natural Attach one manometer hose to the barb located on the back of the pressure switch Attach the other manometer hose to the capped tee barb spliced into the rubber hose running into the combustion chamber see Figure 55 Adjust the air shutter on the right fan until the differential pressure is nominally 1 1 1 3 inches water column Once the adjustment procedure is complete reattach the cap to the tee in the hose and the pressure switch and check all tubing and wire connections for snug fit Test fire the unit Install upper panels Figure55 Combustion Air Adjustment with a Manometer to Set Differential Pressures Servicing Hot Surface Igniter and Ignition Module This pool heater uses a proven hot surface ignition control module and a hot surface igniter The hot surface ignition module is not repairable Any modification or repairs will invalidate the warranty
95. ontrol fault check power LED may be effective do not replace control if all operational sequences function properly see TroubleShooting Guide One Flash Low Air check air pressure switch and hoses to pressure sensing points fan venting and sealing of pressurized chamber Note Brief flashing normal on fan start up proving Two Flashes Flame without call for heat check for a gas valve stuck in the open position air venting burners and the combustion process Fan will remain on Three Flashes Lockout due to flame failure push reset button on outer control panel after correcting ignition problem Initial heater start up without properly bleeding from the gas line may require multiple reset functions to achieve proper ignition Four Flashes Igniter failure igniter will not maintain minimum 2 75 amp current draw caused by low voltage bad wiring continuity high resistance or igniter failure Five Flashes Power supply problem check for low supply voltage or transformer output less than 18VAC Six Flashes Replace ignition module internal fault Access to Internal Control Panel The control panel is accessed by turning the knurled knob located at the bottom center of the exterior control panel Pull the panel out at the bottom The door will tilt into unit until it comes free from the outer top The outer control panel has an overlay attached to the exterior surface which indicates the function of each
96. oor 3 Way Automatic Bypass Valve Cover The pump supplied on the pool heater bypass has a sealed motor suitable for outdoor installations When installing the 3 way automatic bypass valve outdoors an outdoor valve cover is required An outdoor valve cover is supplied with an optional outdoor vent kit see Table H page 26 of this manual To install the outdoor valve cover follow the steps below 1 Turn off power to the unit 2 Remove the plastic actuator cover from the 3 way automatic bypass valve by loosening the screw above the conduit fitting Figure 32 3 Grasp the cover on the screw side and lift the cover up and away from the valve 4 Disconnect the wires at the terminal block if connected 5 Unscrew the plastic conduit cap from the conduit fitting Figure 32 and pull the plastic conduit hose and wires from the valve 6 Feed the plastic conduit hose through the opening of the valve cover end cap JKD6654 see FIG 32 and slide the end cap approximately one foot up the conduit 7 Reconnect the wires to the 3 way valve circuit board as shown in Figure 33 8 Feed the conduit hose into the conduit fitting and reinstall the conduit cap Commercial Pool Heaters INSTALLATION Continued Note If the wing nut underneath the valve actuator body is loose retighten 9 Reinstall the plastic actuator cover and secure with the screw loosened in Step 2 10 Place the valve cover JKD6653 over the 3 way automat
97. oration If you find any problems correct them at once IMPORTANT Vent terminations are not shown in Figures 10 11 12 and 13 Make sure all vertical vents are installed with vent terminations recommended by the vent manufacturer Venting Support Support horizontal portions of the venting system to prevent MORE THAN 10 sagging Provide an upward slope of at least 1 4 inch per foot B 21mm m on all horizontal runs from the pool heater to the 10 vertical flue run or to vent terminal sidewall venting RIDGE 2 MIN installations 3 MIN Do not use an existing chimney as a raceway if another appliance or fireplace is vented through the chimney The weight of the venting system must not rest on the pool heater Provide adequate support of the venting system Follow all local and applicable codes Secure and seal all vent connections Follow the installation instructions from the vent material manufacturer Pas CHIMNEY Vertical Vent Termination Clearances and Location Figurell Vent Termination from Peaked Roof More Than 10 From Ridge The vent terminal should be vertical and exhaust outside the building at least 2 feet 0 61m above the highest point of the roof within a 10 foot 3 05m radius of the termination The vertical termination must be a minimum of 3 feet 0 91m above the point of exit A vertical termination less than 10 feet 3 05m from a parapet wall mus
98. orizontal direct vent system and in the same pressure zone as the vent termination Follow all clearance requirements listed on pages 8 and 9 Purchase and assemble the combustion air inlet cap to protect the air inlet from wind and weather Alternatively assemble the combustion air inlet cap for the vertical rooftop air inlet from items purchased locally The air inlet cap consists of two 90 elbows installed to the air inlet pipe see Figure 26 Install the first 90 elbow on the rooftop at the highest vertical point of the air inlet pipe Install the second 90 elbow on the horizontal outlet of the first elbow The outlet of the second 90 elbow will be pointing down You may use a 90 elbow and a 90 street elbow to make this assembly If you use a straight piece of pipe between the two 90 elbows it should not exceed 6 51mm in length 6 MAXIMUM Figure 26 Vertical Rooftop Air Inlet For horizontal direct vent termination of combustion air you must use the termination cap from the pool heater manufacturer The sidewall air inlet cap is available as part ofa direct vent kit See TABLE G for Horizontal Direct Vent Kits Installation and Service Manual Vertical Combustion Air Inlet Clearances You must locate the air inlet termination elbow at least 12 30cm above the roof or above normal snow levels If the air inlet cap is within a 10 foot 3 05m radius of the flue outl
99. pH range and what Figure 49 Exterior Control Panel with Operation Diagnostic happen when the pH increases or decreases from the ideal Lights and LCD Display of 7 2 to 7 8 pH Scale TABLE O Status LED Diagnostic Codes THE Prepurge Operation of combustion air COFROSON SCALNG oni HEAT HEAT AREA fans before ignition EXCHANGERS R EXCHANGERS E DESTROYED d qp qe pp qe DESTROYED Trial for Ignition Hot surface igniter 1 preparing ae a to light burners LOW pH HIGH pH ACID ALKALINE Heating Burners operating NUR Service Indicator when option FIG 48 Service if equipped puchased Figure 50 pH Scale Indicates flame failure on If the pH becomes too high it lowers the ability of chlorine either ignition module and will to destroy bacteria and algae water can become cloudy filter indicate additional alarms if the elements may become blocked and scale formation will occur alarm of any failure option is in the pool and heat exchanger If the pH becomes too low purchased the water becomes acidic You can have eye burn and skin irritation etching of the plaster corrosion of metal fixtures and the resulting stains on the plaster degradation of sand and gravel filters and corrosion of the copper tubes in the heat Speed This indicates that the speed setting is being displayed The exchanger speed setting controls the responsiveness of the 3 way valve
100. ping on models 500 000 750 000 Btu hr is 2 and on models 990 000 2 070 000 Btu hr the minimum is 2 1 2 The piping from the filter system to the pool heater may be PVC CPVC or Copper Pipe The piping from the pool heater back to the filter system will carry water with temperatures in excess of 110 F and must be CPVC or Copper Pipe The temperature of the heated water from the pool heater will be substantially cooled as it is mixed back into the pool water from the filter system and returned to the pool The mix of heated water and pool water from the filtration system should only be slightly warmer than the pool water before the connections from the pool heater Auxiliary Mixed Water Limit Control Ensure that the auxiliary 110 F mixed water limit control and optional pool supply sensor if used are installed in the filter system piping Install the auxiliary limit a minimum of three feet downstream from the point where the heated water from the pool heater is added to the filtration system See Figures 34 38 The limit and sensor may be mounted in 3 8 NPT tapped fittings installed in the filtration system piping or they may be installed directly into tapped openings in the PVC filter system piping Turn off the filter system pump when installing the auxiliary limit and sensor in the filtration system piping Tapped openings can be added to the PVC pipe by first drilling 9 16 pilot holes in the PVC pipe at least three feet downst
101. plier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Save this manual for future reference Commercial Pool Heaters Table of Contents General Product Information Special Instructions Unpacking Warranty Safety Information Product Identification Installation Locating Pool Heater Clearances from Combustible Construction Base for Combustible Floors Freeze Protection Combustion and Ventilation Air Combustion Air Filter Combustion Air Options Exhaust Fans Venting General Information Venting Support Vertical Vent Termination Clearances and Location Sidewall Vent Termination Clearances and Location Combustion Air Inlet Piping Length of Air Inlet Piping Sidewall Air Inlet Vertical Rooftop Air Inlet Combined Air Inlet Points Vent System Options Barometric Damper Location 1 Conventional Negative Draft Venting 2 Vertical DirectAire Venting 3 Sidewall Venting 4 Horizontal DirectAire Venting 5 Direct Venting 6 Outdoor Installation Venting Connecting to Gas Supply Gas Pressure Test Gas Piping Connecting Gas Piping to the Pool Heater Gas Train and Controls Combination Gas Valves Venting of Combination Gas Valves Checking Gas Supply Pressure Gas Manifold Pressure Adjustment Pool Heater Piping Installation Auxiliary Mixed Water Limit Control Pump
102. position with nylon wire ties Use caution not to collapse or restrict the condensate drain line with the nylon wire ties The condensate drain must be routed to a suitable drain for disposal of condensate that may occur in the direct vent system Refer to the condensate drain installation instructions as supplied by the manufacturer of the vent material Figure 23B Aire Lock Direct Vent Illustration with Sidewall Vent and Sidewall Combustion Air A WARNING Do not combine the flue from this unit with the vent from any other appliance Do not combine flues from multiple appliances into a common vent The flue from this unit must be a dedicated stack Connect the flue vent directly to the flue outlet opening on the top of the pool heater Make the connections from the pool heater vent to the outside stack as direct as possible with no reduction in diameter Provide adequate clearance to combustibles for the vent connector and firestop Follow the vent manufacturer s instructions when installing sealed AL29 4C vents and accessories such as firestop spacers vent connectors thimbles caps etc Provide adequate clearance to combustibles for the vent connector and firestop When planning the venting system avoid possible contact with plumbing or electrical wiring inside walls ceilings and floors Locate the pool heater as close as possible to the chimney or gas vent When a vent
103. pressure for natural gas models should be 1 2 w c For LP gas models the net manifold gas pressure should be 4 6 w c For the proper procedure for measuring net manifold gas pressure reference page 30 of this manual If an adjustment of the net manifold gas pressure is necessary follow the procedure on page 30 of this manual Note The gas valves are factory preset and should not need adjustment However due to installation and environmental conditions adjustment of the gas valves may be necessary for start up 58 4 For negative draft vent systems measure the draft in the vent stack The negative draft should be between 02 w c to 08 w c Reference pages 10 26 of this manual to determine which venting system is in use Note For positive pressure venting systems a draft measurement is not required Ensure that the vent length does not exceed the maximum lengths listed in the Installation and Service Manual 5 Adjust the temperature set point on the digital temperature control to the desired pool temperature Reference pages 40 and 41 of this manual for information regarding the operation and adjustment of the digital temperature control 6 A 3 way automatic bypass valve is factory installed to maintain a minimum temperature of 130 to the inlet of the pool heater to protect against flue gas condensation Manual adjustment of the valve is not required Note Ifthe inlet temperature of the pool heater can not be maintain
104. problems Commercial Pool Heaters INSTALLATION Continued For convenience and flexibility you can direct the combustion air inlet from either the back or right side of the pool heater To arrange the combustion air inlet for side entry follow the steps below 1 Remove the metal panel from the pool heater s side wall see Figure 4 2 Remove screws from the air filter bracket assembly 3 Move the filter bracket assembly from the rear of the pool heater to the side opening see Figure 5 4 Attach the filter bracket assembly to the pool heater s side using the pre drilled screw holes 5 Attach the metal panel to the rear combustion air opening to seal it off SES lt lt 5 o Mem SOI Figure 4 Metal Panel Covering Side Combustion Air Inlet Figure 5 Moving Air Filter Bracket Assembly from Rear of Pool Heater to Side Combustion Air Options This pool heater has four combustion air options 1 Outside Combustion Air No Ducts You can direct outside combustion air to this pool heater using either one or two permanent openings One Opening The opening must have a minimum free area of one square inch per 3000 Btu input 7cm per kW You must locate this opening within 12 30cm of the top of the enclosure Figure 6 Outside Combustion Air Single Opening Two Openings The combustion air opening must have a minimum free area of one square in
105. ration Installation and Service Manual Gas Piping To safely operate this pool heater you must properly size the gas supply piping See Tables J and K for piping and fitting requirements Gas pipe size may be larger than pool heater connection On models 500 000 750 000 Btu hr the gas connection to the pool heaters are 1 1 4 NPT and on models 990 000 2 070 000 Btu hr the gas connections to the pool heaters are 2 NPT IMPORTANT Do not block access to the electrical cover plate when installing the sediment trap The sediment trap must be a minimum of 12 inches from the pool heater Optional gas controls may require routing of bleeds and vents to the atmosphere outside the building when required by local codes Note All secondary regulators MUST BE of the lock up type and spaced a minimum of 6 from the appliance Connecting Gas Piping to the Pool Heater All gas connections must be made with pipe joint compound resistant to the action of liquefied petroleum L P and natural gases All piping must comply with local codes and ordinances Piping installations must comply with approved standards and practices 1 Make sure the gas line is a separate line direct from the meter unless the existing gas line is of sufficient capacity Verify pipe size with your gas supplier Use new properly threaded black iron pipe free from chips If you use tubing make sure the ends are cut square deburred and clean Make
106. ream of the point where the heated water from the pool heater is added to the filter piping The drilled pilot holes can now be carefully threaded with a 3 8 NPT taper tap After the pipe threads have been cut into the PVC pipe wall the limit and bulbwell can be inserted into 31 the tapped openings Apply a small amount of a high quality RTV silicone sealant to the threads to prevent leaks and install the limit and bulbwell into the threaded openings in the pipe Install the limit control and bulbwell and tighten to seal Do not over tighten either part into the threaded openings in the PVC pipe Over tightening can damage the parts and or strip the threads cut into the plastic pipe Install the pool supply sensor into the bulbwell and connect it to the pool heater circuit as shown in the wiring diagram for your model Wire the limit into the pool heater control circuit as shown in the wiring diagram If additional wire length is needed use 18 GA wire for distances up to 30 ft For longer distances size the wire per Table M page 37 Use weatherproof connections for outdoor installation Pumped Automatic Bypass This is a high efficiency pool heater which requires a special pumped bypass for proper operation The bypass assembly supplied with the pool heater includes a pump and a 3 way mixing valve All piping to connect the filter system to the pool heater is made directly to the bypass piping on the pool heater Outdoor Operation Outd
107. rge option is available for this pool heater During extended periods of inactivity during which pumping may have been turned off to conserve energy air can become entrapped in the piping The pump purge option delays pool heater operation until the pump has been on for sufficient time to remove air from piping Both the inactivity time and pump purging time are adjustable The inactive timer is adjustable from 1 99 hours Selection of a time between 4 8 hours is recommended The purge timer is adjustable from 1 60 minutes Selection of a time between 10 to 30 minutes is recommended An override toggle switch is provided to turn off the pump purge feature for testing or should the option no longer be desired When turned off the call for heat will not be delayed Service Indicator Option A service indicator option is available for this pool heater The Service Indicator light on the Diagnostic Information Panel will light up indicating that the pre programmed hours cycles have elapsed Contact a qualified serviceperson to perform service on the pool heater CONNECTING TO ELECTRICAL SUPPLY This pool heater is wired for 120 VAC service The pool heater when installed must be electrically grounded in accordance with the requirements of the authority having jurisdiction or in the absence of such requirements with the latest edition of the National Electrical Code ANSI NFPA No 70 When the pool heater is installed in Canada it
108. rosion on the inside of the copper tube may be caused by too much water velocity through the tubes and is not covered by the appliance manufacturer s warranty Oo Corrosion due to water chemistry imbalance is not the fault of the equipment and is not covered by the appliance manufacturer s warranty see Water Chemistry page 44 SAFETY INFORMATION The information contained in this manual is intended for use by qualified professional installers service technicians or gas suppliers Consult your local expert for proper installation or service procedures IMPORTANT Read this owner s manual carefully and completely before trying to install operate or service this pool heater Improper use of this pool heater can cause serious injury or death from burns fire explosion electrical shock and carbon monoxide poisoning DANGER Carbon Monoxide poisoning may lead to death IMPORTANT Consult and follow local building and fire regulations and other safety codes that apply to this installation Consult your local gas utility company to authorize and inspect all gas and flue connections AN WARNING Should overheating occur or the gas supply fail to shut off do not turn off or disconnect the electrical supply to the pump Instead shut off the gas supply at a location external to the pool heater WARNING To minimize the possibility of serious personal injury fire or damage to your pool heater never violate the f
109. rs LOCATING POOL HEATER 1 Maintain all clearances from combustible construction when locating pool heater See Clearances from Combustible Construction this page Locate the pool heater so that if water connections should leak water damage will not occur When such locations cannot be avoided install a suitable drain pan that is well drained under the pool heater The pan must not restrict combustion air flow The pool heater manufacturer is not responsible for water damage in connection with this pool heater or any of its components Install the indoor pool heaters so that the ignition system components are protected from any water while operating or during service You must install the pool heater on a level non combustible floor Do not install pool heater directly on carpet or other combustible material A concrete over wood floor is not considered non combustible Maintain required clearances from combustible surfaces If installing the pool heater in an area with a combustible floor you must construct a special combustible floor base See Base for Combustible Floors this page For outdoor models you must install an optional vent cap Instructions for mounting the vent cap are included in the venting section Do not install outdoor models directly on the ground You must install the outdoor pool heater on a concrete brick block or other non combustible pad Outdoor models have additional spe
110. s must be diluted into the pool water being circulated through the pool heater Any concentration of chlorine in the pool heater can cause damage to the pool heater Do not place chlorine tablets or bromine sticks in the skimmer High chemical concentrations will result when the pump is not running Chlorinator must feed downstream of the pool heater and have an anti siphoning device to prevent chemical back up in the pool heater when the pump is shut off IMPORTANT High chemical concentrations from improperly adjusted feeders and Chlorinator can cause rapid corrosion to the heat exchanger This damage is non warrantable 35 Water Flow Switch A water flow switch is standard equipment The wiring connection installs the flow switch in the 24 VAC safety circuit to prove water flow before main burner ignition The standard flow switch is installed in the outlet side of the piping loop when shipped from the factory These pool heaters require a sufficient flow of 26 GPM to make the flow switch and start burner operation Commercial Pool Heaters INSTALLATION Continued Ensure that the pump installed on the pool heater will supply adequate flow to make the flow switch contacts and operate the pool heater A water flow switch meets most code requirements for a low water cut off device on appliances requiring forced circulation for operation PUMP PURGE MAINTENANCE TIMER OPTION Pump Purge Delay Option An electronic pump pu
111. s not run continuously an additional pump must be installed to provide constant circulation through the pool heater The constant flow of warm pool water can help prevent freezing 2 Anytime the temperature measured at the sensor drops below 45 F the temperature control turns on the pump to circulate the water if the pump option is installed Q2 Location Indoor pool heaters must be located in a room having a temperature safely above freezing 32 F 0 C 4 Outdoor Pool Heater Installation Use extreme caution to prevent freezing snow screen should be installed to prevent snow and ice accumulation around the pool heater or its venting system Shut Down and Draining If for any reason the pool heater is to be shut off the following precautionary measures must be taken a Shut off gas supply b Shut off water supply c Shut off electrical supply d Drain the pool heater completely Remove the threaded drain plugs from the inlet and outlet sides of the front header on the heat exchanger see Figure 3 Blow all water out of the heat exchanger Leave drains open until Spring oO Drain pump and piping DRAIN PLUG pA PLUG d Figure 3 Draining Pool Heater Me CAUTION Under no circumstances should the equipment room ever be under a negative pressure Particular care should be taken where exha
112. s to the ON position 1 8 HEX INLET 17 Set the temperature control to call for heat PRESSURE TAP A WARNING After completing any testing on the gas system leak test all gas connections Apply a soap water solution to all gas connections while main burners are operating Bubbles forming indicate a leak Repair all leaks MANOMETER at once Do not operate this pool heater with a leak in the gas train valves or related piping GAS VALVE LS CONTROL KNOB Check burner performance by cycling system while you OUTLET observe burner response Burners should ignite promptly Flame pattern should be stable see Burner Flames page 47 Turn system off and allow burners to cool then cycle burners again to ensure proper ignition and flame characteristics Figure 30 Measuring Gas Supply Pressure at Combination Gas Valve TABLE K Multiple Unit Installations Gas Supply Pipe Sizing Nominal Length of Pipe in Straight Feet Iron Pipe Size N o NN N Os W E ion Uu N A Inches idi 636 1 560 1 440 1 330 1 250 1 180 1 100 CET 4 100 2 260 1 950 1 720 6 460 3 610 3 100 2 720 2 460 2 100 2 000 1 900 1 700 DIES 1 540 1 300 EN 11 200 8 900 6 400 4 870 4 410 3 800 3 000 2 720 2 340 o p uu E 9 000 7 690 7 380 6 150 5 640 Maximum capacity of pipe in thousands
113. st be performed by a qualified service installer service agency or the gas supplier Unpacking Upon receiving equipment check for signs of shipping damage Pay particular attention to parts accompanying the pool heater which may show signs of being hit or otherwise being mishandled Verify total number of pieces shown on the packing slip with those actually received In case there is damage or a shortage immediately notify the carrier Codes The equipment shall be installed in accordance with those installation regulations in force in the local area where the installation is to be made These shall be carefully followed in all cases Authorities having jurisdiction shall be consulted before installations are made In the absence of such requirements the installation shall conform to the latest edition of the National Fuel Gas Code ANSI Z223 1 and or CAN CGA B149 Installation Code All pool heater heat exchanger construction conforms to the latest edition of the ASME Boiler and Pressure Vessel Code Section IV Part HLW Warranty Factory warranty shipped with pool heater does not apply to pool heaters installed or operated improperly Improper installation or system design causes most operating problems 1 Excessive water hardness causing a lime build up in the copper tube is not the fault of the equipment and is not covered under the appliance manufacturer s warranty see Water Chemistry page 44 2 Excessive pitting and e
114. system is disconnected for any reason the flue must be reassembled and resealed according to the vent manufacturer s instructions The installed length of flue from the pool heater to the outside point of termination must not exceed 50 equivalent feet 15 2m Subtract 5 feet 1 5m of equivalent length for each 90 elbow Subtract 2 5 feet 0 7m of equivalent length for each 45 elbow Commercial Pool Heaters INSTALLATION Continued Masonry Chimney Installation Do not use a standard masonry chimney to directly vent the combustion products from this pool heater To use a masonry chimney the chimney must use a sealed corrosion resistant liner system Sealed corrosion resistant liner systems singlewall doublewall flexible or rigid must be rated for use with a high efficiency positive pressure vent system Corrosion resistant chimney liner systems are typically made from a high grade stainless steel such as AL29 4C The liner must be properly sized and fully sealed throughout the entire length Both the top and bottom of the masonry chimney must be capped and sealed to provide a dead air space around the liner A WARNING Do not vent this pool heater into a masonry chimney without a sealed stainless steel liner system Any breaks leaks or damage to the masonry flue tile will allow the positive pressure flue products to leak from the chimney and into occupied living spaces This could cause serious injury or death due to car
115. t be a minimum of 2 feet 0 61m higher than the parapet wall You must locate the air inlet termination elbow at least 12 30cm above the roof or above normal snow levels Keep the vent cap clear of snow ice leaves and debris to avoid blocking the flue Installation and Service Manual 10 OR LESS Provide a minimum clearance of 4 feet 1 2m horizontally from electric meters gas meters regulators and relief equipment Never locate the vent cap above or below electric meters gas meters regulators and relief equipment unless a 4 foot 1 2m horizontal clearance is maintained 2 MIN 2 MIN Terminate venting system at least 3 feet 0 9m above 3 MIN forced air inlet within 10 feet 3 05m Terminate the venting system at least 4 feet 1 2m below 4 feet 1 2m beside or 1 foot 30cm above any door window or gravity air inlet into any building Locate vent termination at least 8 feet 2 4m horizontally from any combustion air intake located above the sidewall termination cap A Pe CHIMNEY WALL OR CHIMNEY PARAPET A CAUTION Pool heaters which are shut down or will not operate may experience freezing due to convective air flow in the flue pipe through the air inlet or from negative pressure in the equipment 10 ORLESS room In cold climates operate pump continuously to help preve
116. ter CONNECTING TO GAS SUPPLY Only supply gas type specified on the pool heater s rating plate This pool heater is orificed for operation up to 2000 feet altitude If installing above 2000 feet elevation consult the pool heater manufacturer INLET PRESSURE Measure inlet pressure at the inlet pressure tap located upstream of the combination gas valve s See TABLE I for maximum and minimum inlet pressures Do not exceed the maximum Minimum inlet pressure is for the purposes of input adjustment TABLE I Inlet Pressure MANIFOLD PRESSURE Measure manifold pressure at the pressure tap on the downstream side of the combination gas valves The gas regulator on the pool heater s combination gas valves is preset at the factory to supply proper manifold pressure for normal operation See TABLE L page 31 for net manifold pressure settings If you must adjust regulator pressure follow the instructions under Gas Manifold Pressure Adjustment page 30 Do not increase regulator pressure beyond specified pressure setting Gas Pressure Test 1 Disconnect the unit from the gas supply piping system during any piping system pressure testing greater than 1 2 PSIG 3 5kPa 2 Isolate the pool heater from the gas supply piping system by closing a manual shutoff valve during any piping system pressure testing that is equal to or less than 1 2 PSIG 3 5kPa 3 Test all gas connections for gas leaks before placing the pool heater in ope
117. ter manufacturer in accordance with CSA International requirements This venting kit includes the powered sidewall fan cap proving switch and all necessary relays to interlock with the pool heater s control system The sidewall fan powered vent cap must be interlocked with the pool heater s control system to start the fan on a call for heat and prove fan operation before the pool heater fires Plug in and terminal strip connections are provided on the pool heater for easy connection of the factory supplied vent kit and control package for the sidewall vent fan 18 Sidewall Venting Without Fan For 500 000 750 000 Btu hr models approved for sidewall venting without an external power vent fan you must install specific vent kits and venting materials The following is a detailed explanation of Sidewall Venting Without an External Fan installation requirements Flue Outlet Piping Venting Guidelines If using this venting option a sealed AL29 4C venting system for flue products is required on all models of this pool heater This venting system operates with a positive pressure in the vent The internal combustion air blowers generate this positive pressure which operates the combustion process and also exhausts the flue products from the building This vent system has specific vent material and installation requirements Only use listed sealed AL29 4C vent system materials Follow all installation requirements See TABLE B page 11 for
118. the burner ports by rinsing the burner thoroughly with water Drain and dry burners before re installing Damaged burners must be replaced When installed in a dusty and dirty location the burners may require cleaning on a 3 to 6 month schedule or as needed based on severity of contamination Contaminants can be drawn in with the combustion air Non combustible particulate matter such as dust dirt concrete dust or dry wall dust can block burner ports and cause non warrantable failure The standard inlet air filter will help eliminate dust and dirt from entering the pool heater Heat Exchanger Cleaning 1 While burners are removed check the heat exchanger surface for sooting If present the heat exchanger must be cleaned and the problem corrected Proceed as follows Remove gas manifold s orifice assemblies as described in steps 1 through 5 in Burner Removal and Cleaning this page Disconnect the wiring from the hot surface igniter and the hoses from the burner pressure tap Remove inner jacket panel mounting screws and slide the door assembly out toward the front of the pool heater Use caution to prevent damage to the refractory and hot surface igniter Check V baffles along the front and back edges of the heat exchanger Remove and clean if necessary Remove soot from the heat exchanger with a stiff bristle brush Use a vacuum to remove loose soot from the surfaces and inner chamber The heat
119. tical DirectAire vent system requires you to install two vent pipes directly to the pool heater one vertical pipe with a rooftop termination for the flue products and one pipe for combustion air For this venting option you must purchase the DV box adapter The DV box attaches to the air inlet of the pool heater The pipe for combustion air attaches to the DV box 16 You can terminate the combustion air pipe either horizontally with a sidewall air inlet or vertically with a rooftop air inlet The installed length of air inlet pipe from the pool heater to the outside air inlet cap must not exceed 50 equivalent feet 15 2m ge c __ Figure 18 Vertical DirectAire Installation with Sidewall Combustion Air Inlet Figure 19 Air Inlet Cap for Sidewall Termination Installation and Service Manual Y T Figure 20 Vertical DirectAire Installation with Rooftop Combustion Air Inlet Vent Kits WARNING Only use a sidewall air inlet cap supplied by the appliance manufacturer or a rooftop air inlet cap supplied by the vent manufacturer Using any other air inlet cap for single unit installations or using a common air inlet cap for multiple units with insufficient free area and or protections from wind and weather may result in operational problems and the spillage of flue products Spillage of flue pr
120. tions are tight 6 Relief valve has been piped to a suitable floor drain 7 Combustion air openings are not obstructed in any way Starting the Filter System Verify proper installation of the pool heater temperature controls and the installation of the 110 F auxiliary limit and pool supply sensor in the mixed discharge water from the filter piping to the pool Clean the filter Start the filter pump Be sure all air is out of all the lines including the pressure connection Ensure that the pool heater is not air bound by manually opening the temperature and pressure relief valve Leave the valve open until a steady flow of water is observed at the discharge from the valve Close the valve and complete filling the system Note Backwash the filter when the G P M filtration rates are too low to meet local codes or state code A high temperature rise across the pool heater is also an indication oflow flow in the filter system Sustained low flow to the pool heater will result in cycling of the heater on the limit controls and possible opening ofthe relief valve Commercial Pool Heaters OPERATION Continued Figure 44 Vertical Pool Heater Piping Figure 45 Horizontal Pool Heater Piping OPERATING TEMPERATURE CONTROL The pool heater is equipped with a microprocessor based adjustable digital temperature control to provide ON OFF operation The temperature control is located behind the overlay on the front of the control pa
121. to the latest edition of the National Fuel Gas Code ANSI Z223 1 in Canada the latest edition of CAN CGA B149 Installation Code for Gas Burning Appliances and Equipment When resizing any portion of the common venting system resize to approach the minimum size as determined using the appropriate tables of the latest edition of the National Fuel Gas Code ANSI Z223 1 in Canada the latest edition of CAN CGA B149 Installation Code for Gas Burning Appliances and Equipment Commercial Pool Heaters INSTALLATION Continued Masonry Chimney Installations A masonry chimney must be properly sized for the installation of a high efficiency gas fired pool heater Venting of a high efficiency pool heater into a cold or oversized masonry chimney can result in operational and safety problems Exterior masonry chimneys with one or more sides exposed to cold outdoor temperatures are more likely to have venting problems The temperature of the flue products from a high efficiency pool heater may not be able to sufficiently heat the masonry structure of the chimney to generate proper draft This will result in condensing of flue products damage to the masonry flue tile insufficient draft and possible spillage of flue products into an occupied living space Carefully inspect all chimney systems before installation Inspection of a Masonry Chimney A masonry chimney must be carefully inspected to determine its suitability for the venting of flue products
122. to the next step 10 Turn the manual gas cock counterclockwise to the ON position 11 Turn the power switch to the ON position 12 Slide the control panel assembly back into the pool heater Tighten the knurled screw at the bottom of the control panel cover 13 If the pool heater will not operate follow the instructions To Turn Off Gas To Appliance and call your service technician or gas supplier To Turn Off Gas To Pool Heater 1 Open the front access panel to access the control panel 2 Turn the power switch to the OFF position 3 Turn manual gas cock clockwise to the OFF position WARNING Should overheating occur or the gas fail to shut off turn off the manual gas control valve to the pool heater PRESSURE REGULATOR 1 8 HEX INLET ADJUSTMENT PRESSURE TAP UNDER CAP SCREW GAS VALVE CONTROL KNOB REFERENCE HOSE CONNECTION WIRING 1 8 HEX INLET TERMINALS PRESSURE TAP OUTLET Figure 43 Combination Gas Valve 39 and Service Manual Pre Start Checklist Before attempting to start the pool heater verify that the following items have been checked 1 Verify proper location and installation of the pool heater 2 Check gas piping and ensure the gas line is purged of all air 3 Ensure that the pool is properly filled 4 DO NOT operate pool heater if improperly filled 5 Check to ensure that all water connec
123. trol 4 24V AC is then supplied to the 110 F mixed water limit control and onto the 200 F fixed limit control Ifequipped 24VAC is supplied to a low water cut off and then to the optional high and low gas pressure switches 24VAC is supplied to the terminal strip and onto the switching contacts of the digital temperature control The digital temperature control will then call for heat 24VAC is then supplied to the water pressure switch and the flow switch if equipped 24V AC is then supplied to the TH terminals on the ignition module 51 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 As power is applied to the TH terminals on the ignition module 120VAC is switched from the F2 terminal to start the combustion air fan s 24V AC is supplied to the C terminal of the air pressure switch As the low air switch makes power is supplied to the optional louver venter enable contact relay 24V AC is then supplied to the PS terminals on the ignition module The combustion air fan operates for the pre purge period At the end of the pre purge period 120VAC is applied to the hot surface igniter and the trial for ignition light The hot surface igniter proves 1800 F 982 C ignition temperature by the current draw through the ignition module The ignition module supplies voltage to the MV terminals onto the gas valve s The first stage gas valve opens and supp
124. used to supply combustion air to the equipment room the installer must make sure that it does not cause drafts which could lead to nuisance operational problems with the pool heater Vertical DirectAire and Horizontal DirectAire venting systems have specific requirements for combustion air ducts from the outside which are directly connected to the pool heater See the requirements for combustion air duct in the venting section starting on page 12 Commercial Pool Heaters INSTALLATION Continued VENTING General Information 10 OR LESS i 2 MIN You must supply adequate combustion and ventilation air to this pool heater You must provide minimum clearances for the vent 3 MIN terminal from adjacent buildings windows that open and building RIDGE openings Follow all requirements set forth in the latest edition of the National Fuel Gas Code ANSI Z223 1 in Canada the latest edition of CAN CGA Standard B149 Installation Code for Gas Burning Appliances and Equipment or applicable local building codes Vent installations for connection to gas vents or chimneys must be in accordance with Part 7 Venting of Equipment of the CHIMNEY above mentioned standards IMPORTANT Examine the venting system at least Figure 10 Vent Termination from Peaked Roof 10 once each year Check all joints and vent pipe Less From Ridge connections for tightness Also check for corrosion or deteri
125. ust fans attic fans clothes dryers compressors air handling units etc may take away air from the pool heater COMBUSTION AND VENTILATION AIR Provisions for combustion and ventilation air must be in accordance with Section 5 3 Air for Combustion and Ventilation of the latest edition of the National Fuel Gas Code ANSI Z223 1 in Canada the latest edition of CAN CGA B149 Installation Code for Gas Burning Appliances and Equipment or applicable provisions of the local building codes Provide properly sized openings to the equipment room to assure adequate combustion air and proper ventilation when the pool heater is installed with conventional venting or sidewall venting Combustion Air Filter This pool heater has a standard air filter located at the combustion air inlet This filter helps ensure clean air is used for the combustion process Check this filter every month and replace when it becomes dirty The filter size on the 500 000 750 000 units is 12 x 12 x 1 30 5cm x 30 5cm x 2 5cm and 16 x 16 x 1 40 6cm x 40 6cm x 2 5 cm on the 990 000 2 070 000 units You can find these commercially available filters at any home center or HVAC supply store Use filters rated for a maximum face velocity of 300 ft min at a maximum pressure drop of 0 5 water column w c Pleated filters may be used provided they meet these specifications CAUTION Some pleated filters are too restrictive and could cause air flow
126. w ice leaves debris etc Do not install outdoor models directly on the ground You must install the outdoor pool heater on a concrete brick block or other non combustible pad Do not locate the pool heater so that high winds can deflect off of adjacent walls buildings or shrubbery causing recirculation Recirculation of flue products may cause operational problems bad combustion or damage to controls Locate unit at least 3 feet 0 91m from any wall or vertical surface to prevent wind conditions from affecting performance Multiple pool heater outdoor installations require 48 1 22m clearance between each vent cap Locate the outdoor cap at least 48 1 22m below and 48 1 22m horizontally from any window door walkway or gravity air intake Locate the pool heater at least 10 feet 3 05m away from any forced air inlet Locate pool heater at least 3 feet 0 91 m outside any overhang Clearances around outdoor installations can change with time Do not allow the growth of trees shrubs or other plants to obstruct the proper operation of the outdoor vent system Do not install in locations where rain from building runoff drains will spill onto the pool heater Commercial Pool Heaters INSTALLATION Continued TABLE H Outdoor Vent Cap Kits These kits include an outdoor vent cap and gasket Flue gas condensate can freeze on exterior walls or on the vent cap Frozen condensate on the vent cap can result in a bl
Download Pdf Manuals
Related Search
Related Contents
Philips DLA4203 VE 750 - Domyos 065 32 00 Rev1 Folheto de Instruções Lq Diamante Filtro.cdr Paracol Strati/F LIEGE – 13 Décembre 2013 « Lille 2004, Mons 2015, outils graph and fit coefficient Quark CopyDesk 7.0 Passport Upgrade Service Manual - Amalgamated Pumping Supplies Progress Lighting P3715-31 Installation Guide Copyright © All rights reserved.