1. NC switch Switches on for the set period min 1 min for time settings less than 1 min exception short time pulse JL Switches on for the set period min 1 min for time settings less than 1 min exception short time pulse IL 6800 xxx 104 M 6800 3x 102C 6813 101 NO switch Switches on for 80 s independently of ambient brightness 6805 U 160 s as addition of main and slave units NO switch Switches on for the set period min 1 min for time settings less than 1 min exception short time pulse JL 6805 U Setting of short time pulse IL NO switch Switches on for the set period exception short time pulse IL 6805 U Setting of short time pulse JL and daytime operation NO switch Switches on for 80 s independently of ambient brightness 6805 U 160 s as addition of main and slave units NO switch Switches on for the set period min 1 min for time settings less than 1 min exception short time pulse IL 6805 U Setting of short time pulse JL NO switch Switches on for the set period min 1 min for time settings less than 1 min exception short time pulse IL NO switch Switches on for the set period exception short time pulse 4L 6805 U Setting of short time pulse Land daytime operation 6402 U 6810 21 x 101 NO switch Switches on for 80 s independently of ambient brightness 6805 U 160 s as addition of main and slave units NO switch Swi
2. test operation and set ting of the activation can be conveniently operated remotely or adjusted SENSITIVITY ai BUSCH JAEGER 4 Via infrared manual transmitter A Pr This function activates the test operation for an unlimited period independently of the parameters set at the Busch Watchdog Continuous light and simulated presence are terminated The test mode is exited via the TEST OFF Dutton In the T S operating mode standard mode or alarm mode is imme diately activated only Busch Watchdog 220 AlarmLINE Note Activation of the contin uous light and simulat ed presence also termi nates the test opera tion Compulsory cutout After 90 mins the Watchdog switches the light off for approx 2 s in order to determine the current ambient brightness in this peri od The light is then switched back on de pending on the detect ed movement and the set brightness switch threshold Factory setting always deactivated D only Busch Watchdog 220 AlarmLINE Activating deactivating the 2nd switch output for detecting in the security zone Factory setting always activated This is a particular advantage with units mounted high Continuous light 4 hrs On Off see P 16 Acti vation of this function ends the test opera tion Sensitivity is selectable In house operation normal N or busy environment trees bushes in surveillance zone
3. Corner adapter for Infrared manual Infrared service Busch Watchdog transmitter manual transmitter ProfessionalLINE Flush mounted devices presence indicators Busch Watchdog Busch Watchdog Busch Watchdog RC element 180 UP Comfort Il 180 UP Standard Allwetter 44 Request separate user manual 0001 0 0222 Busch Watchdog Surface mounted housing Infrared manual Prasenz tech for Busch Watchdog transmitter for Prasenz tech Busch Watchdog Presence tech 20 Busch Watchdog flush mounted range The table shows the flush mounted range including the presence indicator in overview Busch Watchdog flush mounted range Standard Comfort Il 6810 212 214 101 6800 21X 104 6800 2X 104 6800 8X 104 6800 7X 104 N c a 7 S a V _ _ 6813 xxx 101 6800 21X 104M 6800 2X 104M 6800 8X 104M 6800 7X 104M N c a P Relay unit MOSFET unit 700 WAA 60 420 W VA 3 wire technology 2 wire technology 2 wire technology I Ile ut Le ut Ve Detection levels ca 3 4 ca 2 t Select lens 0 8m 1 2m Multi lens 0 8 m 2 5 m Combination lens Universal central dimmer Universal serial unit Slave unit 60 420 W VA 2 300 W VA 3 wire technology 3 wire technology IT gt IB 78 U We Surveillance zone Mounting height Front Side 0 3 1 2m 12m 8m 8m 8m Mounting height Front Side 1 2 m 10m 2 5 m 20M
4. Light continually switches on and off automatically Sunlight or heat reflection readjust Surveillance zone or insert masking strips Sudden heat change storm rain snow ventilators etc In detection zone readjust detection zone or if necessary select a more pro tected installation site Animals in detection area Watchdog does not react to changes at dusk sensor Possible cause remedy e Unit bridged with switch or similar switch off e Heat source detec tion range realign Watchdog or cover with masking strip e Unit in continuous light mode switch off continuous light or simulated pres ence via infrared manual transmitter e Voltage pulse from switched transtorm ers relays contacts without overvoltage filters connect RC element parallel to connected load e Distance to activated light too small increase distance or cover angle of incidence with masking strip e Watchdog is working in dazzle proof mode normal PR O Busch Jaeger em Elektro GmbH V A member of the ABB Group Busch Jaeger Elektro GmbH P O Box 58505 L denscheid Freisenbergstra e 2 58513 L denscheid Germany www Busch Jaeger com info bje de abb com Central sales service Phone 49 2351 956 0 Fax 49 2351 956 1380 Product brochure BJE 0001 0 1041 03 06 0502 D dpi 402167 Busch Jaeger products are available from your electrical specialist
5. detection zone The masking strips With the masking strips areas that are not to be monitored can be specifically excluded trom the surveillance zone The masking strips can also be used to adjust the surveil lance range for distinct surveillance zones Tip With the corner adapter order no 6887 the unit can be fitted to a house corner or down pipes Connection and settings The watchdog is con nected with the wall mounted socket The Watchdog is simply clipped into place bayonet catch To match the Busch Watchdog Profes sionalLINE 220 280 and AlarmLINE units perfectly to the ambient conditions the follow ing variables are exter nally adjustable Test Standard operation T S In this operating mode the shortest time set ting of two seconds always applies in the daytime to define the surveillance zone irre spective of the set delay time After the test phase of 10 mins the Watchdog automatically changes back to the Standard operating mode Time setting It specifies the delay time activated after the surveillance zone Is vacated Beside exact time settings a short time pulse is provided 1 min 10s Sensitivity The Busch Watchdog works in 3 sensitivity level settings Level N Normal is standard Greater sensitivity Is e g intended for interi or applications In the operating mode the Alarm mode only 220 AlarmLINE With the Busch Watch
6. 12m 4m 15m 5m 2 5m Mounting height Front Side 1 2m o nnn 9m 4m 20m e 12m 8m 25m 15m 10m Allwetter 44 6800 3X 102C Em 2 E IP 44 Frost proof to 25 C Important Outdoors use only with 6401 U 102 Switch off behaviour In combination with 6593 U soft Off function the Comfort Il sensor dims down and switches off within 60 seconds 2020 US NO switch Universal relay unit 3 wire technology Narrowing the detection zone Horizontal Fit masking strips on sides Fit masking strips on sides Fit masking strips on sides Vertical No narrowing possible since there is only one detection level By covering the wide range detec tion can be limited to the close range Mounting Remote Near height 1 2m 2 0m 2 5m By covering the wide or medium range detection can be limited to the medium or close range Mounting height 1 2m 2 0m 2 5m Remote Middle Near 21 Possible combinations and functions of flush mounted devices for slave unit operation The flush mounted devices can be func tionally extended with a slave unit The table shows an overview 6812 U 101 6810 21 x 101 NC switch Switches on for 80 s independently of ambient brightness 6800 xxx 104 M 6813 101 6804 U 101 6810 21 x 101 6800 xxx 104 M 6813 101 6401 U 102 6810 21 x 101 NC switch
7. D only Busch Watchdog 220 AlarmLINE Activate deactivate day operation brightness sensor switched off for evaluation of the security zone Factory setting always deactivated oy ito only Busch Watchdog 220 AlarmLINE Activates deactivates the warning lamp de tection in the security zone Can be cut in in comfort mode and deselected in alarm mode in only Busch Watchdog 220 AlarmLINE Activate deactivate direction recognition during alarm operation When the Watchdog is approached previous penetration of detec tion levels 1 or 2 see P 6 and subsequent entry of the security zone the 2nd switch output and the warning lamp are switched on But not when the per son moves away from the Watchdog or is present in the security zone Factory setting deactivated in com fort mode activated in alarm mode A EN only Busch Watchdog 220 AlarmLINE Activate deactivate synchronous operation The two relays switch synchronously with the Busch Watchdog AlarmLINE The detec tion levels 1 4 see P 6 are evaluated here Detection in the securi ty zone is only indicat ed via the warning lamp if activated Factory setting always deactivated Simulated presence On Off see Page 16 Activation of this func tion ends the test oper ation E Resetting to factory settings or values set at the device for sensi tivity and operating mode All parameters
8. This is the optimum installation height The readings given here see P 10 were taken at an ambi ent temperature of 20 C with an approach from the side range fluctuations e g on account of weather conditions see Page 8 The minimum dis tance between the Busch Watchdog and the switched lights is 1 5 m The tempera ture change of a light installed near the sen sor could otherwise cause the sensor to reactivate after it has been switched off Spotlights should not be aimed directly at the Busch Watchdog Installation The new Professional class has new possi bilities for setting the Busch Watchdog The head of the Busch Watchdog can now be adjusted on 3 axes The range to the front can be adjusted by turn ing and tilting the sensor component and to the side by partial covering of the lens masking strip see Page 14 Inclined locations can be compensated by lateral turning 30 of the Busch Watchdog on the wall connection boxes If parallel inductances such as relays fluores cent lamps or transform ers are switched with the Busch Watchdog we recommend the use of an RC suppressor order no 6899 parallel to the consumer Because the Busch Watchdog is an elec tronic device the instal lation of a surge arrester parallel to the power Supply Is advisable since parallel induc tances can cause over voltages in the range of 3 000 4 000 volts The adjusters must a
9. U in combination with Busch Watchdog Slave Units 6805 U and NO switches Tip The following ABB i bus EIB KNX binary inputs can be used 6156 EB 6188 13 6188 16 6197 11 102 6172 AG 101 or 6173 AG 101 e Activation of a stair case light timer switch e Increase of switching power to more than 3 680 W VA Note For illuminated switch es a separate N is required Neutral conductor is required for 6401 U 102 Busch Universal Relay Unit and 6593 U Busch Universal Central Dimmer Note With the Busch Watchdog in combi nation with a staircase light timer switch the short time pulse setting 1 s must be selected Note In combination with the Busch Universal Central Dimmer 6593 U in operating mode 4 Soft OFF the light is dimmed within 60 s and then switches off 25 Examples of typical circuits for flush mounted units switch 6812 U 101 6804 U 101 6804 U 101 switch 6805 U 6804 U 101 6401 U 102 6805 U 6805 U 26 Activating the Busch Watchdog 180 UP Standard or Comfort with relay unit 6812 U 101 via NC switch When the power to the Busch Watchdog is briefly interrupted by the switch it is automati cally activated for the specified time Extension of surveil lance zone by parallel switching of several MOS Fet units 6804 U 101 Activating the Busch Watchdog 180 UP with 6401 U 102 6804 U 101 or 6593 U via NO switch When
10. dog 220 AlarmLINE d in this operating mode the warning light and the direction dependent switching of the 2nd detection zone security zone are activated After the value drops below the set bright ness threshold when the security zone Is Test function To simplify adjustment during installation the delay time is set to two seconds in the Test posi tion The dusk sensor is then disabled Once the desired setting has been found after testing the settings in the surveil lance zone select the desired delay time and the dusk value to com plete the installation Short time pulse IL e g for activating bell systems Every 10 s a pulse lasting 1 s is generated With the Busch Watchdog 220 AlarmLINE the short time pulse only affects switch output 1 sensitivity for a busy environment trees or bushes is reduced entered from outside the 2nd switch output is acti vated for max 3 mins and the warning lamp for 30 s In event of addition al detection the delay time restarts When the person moves away from the Watchdog there is no reaction from the warning light and switch output of the security zone Only the switch output of the Standard operation The delay time 3 mins and the dusk value 4 Lux are specified Dusk setting Specifying unit activity according to ambient brightness 0 5 300 Lux daytime operation Note only 220 AlarmLINE The delay time of the 2nd Switch outp
11. for physical reasons it cannot guarantee a complete elimination of all unwanted switching operations under all conditions Function overview Busch Watchdog 90 ProfessionalLINE surface mounted Detection angle 90 Surveillance levels 4 Close range detection Rearfield detection e 1st detection zone e Range frontal max 12m Range lateral max 6m 2nd detection zone Range frontal max Range lateral max Direction independent detection Sensitivity adjustable Microprocessor Autom range stabilisation Autom interference suppression Dazzle proof Integrated test function e High capacity relay 16 AX Additional switch output Potential free switch contact Temperature range 25 55 C Dusk sensor e Off delay en Compulsory cutout after 90 mins Short time pulse 1 s Suitable for incandescent lamps e Suitable for fluorescent lamps e Suitable for low voltage halogen lamps e Water protection 2255 Wall mounting Ceiling mounting e Corner mounting e Masking strips cover foil e Remote control anthracite 6853 AGM 35 brown 6853 AGM 201 white 6853 AGM 204 silver metallic 6853 AGM 208 X designation relay can also switch capacitive loads For detection in the security zone Combined adjustment for dusk sensor and off delay With corner adapter 6887 xxx 10 Can be deactivated via infrared service manual transmitter 6842 220 ProfessionalLINE 220 SelectLINE 280 ProfessionalLIN
12. max 1 A Coupling the Busch Watchdog AlarmLINE to ABB Powernet EIB E g for further process ing detection signals at the room control panel ia Actuate the button on the infrared service manual transmitter Tip The two switch outputs can be coupled via the infrared service manual transmitter synchro nous operation Tip The following ABB Powernet EIB binary inputs can be used 6963 U 6967 60 or 6956 EB Important For reasons of stan dards electronic switches must only switch one phase i a EN Actuate the button on the infrared service manual transmitter Examples of typical circuits for surface mounted flush mounted units EIB Bus Busch Watchdog Lamp Installation AlarmLINE bus EIB binary input Busch Watchdog RC element ae relay Two way Busch Watchdog circuit switch Busch Watchdog Coupling the Busch Watchdog AlarmLINE to ABB i bus EIB KNX E g for further pro cessing detection signals at the room control panel Connection of an external relay contactor e Extension of the Off delay e Activation of a pulse relay e g for flash ing lights Combination of an existing two way circuit with Busch Watchdog Busch Watchdog 180 UP Two way circuit and movement detector have the same priority Activation of lighting with Busch Watchdog 180 UP Standard or Comfort Il with 6401 U 102 6804 U 101 or 6593
13. Continuous light L of outdoor lighting 2 Light switched off N The following functions 3 Movement detector can be selected via the operation 3 st ge _ 2 13 U switch Lam or 6a Lamp Busch Watchdog LS16A nee switch for Tip L switching over to e toggle contro N a PERMANENTLY ON switch insert In Busch Watchdog 2000 6 USK can operation the control be used so that lamp signals that the the control lamp connected light has can be connected been switched on to the neutral wire Control status signal Off switch Busch Watchdog Parallel operation LS 16A of several Busch aa Watchdogs E g combined with a continuous light switch for several house sides Off switch Busch Watchdog 23 Examples of typical circuits of Busch Watchdog AlarmLINE 24 Busch Watchdog AlarmLINE Busch Watchdog AlarmLINE Busch Watchdog AlarmLINE Busch Watchdog AlarmLINE Lamp 1 Comfort mode of Busch Watchdog AlarmLINE 2 independent light circuits are switched depending on the dis tance to the movement detector e g path and house door lighting Increase of total switching capacity to 2x 2 300 W VA Note The two switch out puts can be coupled via the infrared service manual transmitter synchronous opera tion Switching low voltage signals with the Busch Watchdog AlarmLINE Note The voltage range for the potential free switch output is between 12V to 48 V at min 10 mA to
14. E 25 55 C 6845 AGM 35 6845 AGM 201 6845 AGM 204 6845 AGM 208 2202 16m 16 m 25 55 C 6845 AGS 35 6845 AGS 204 25 55 C 6848 AGM 35 6848 AGM 201 6848 AGM 208 220 AlarmLINE 10 AX 10 AX 25 55 C 6849 AGM 35 6849 AGM 201 6849 AGM 204 6849 AGM 208 For the 2nd detection zone 6 m Simultaneous switching with 1st detection zone 16 m can be activated via infrared service manual transmitter 6842 Range Surveillance range A high surveillance density is crucial to guarantee the detection quality of amovement detector In the Busch Watchdog up to 416 closely packed large Busch Watchdog 90 ProfessionalLINE Busch Watchdog 220 AlarmLINE Busch Watchdog 220 ProfessionalLINE Busch Watchdog 220 SelectLINE Busch Watchdog 280 ProfessionalLINE area switching seg ments monitor the sur veillance zone in up to 104 sectors This large number of operating points guarantees reli able switching even for small movements Its wide range of up to 16 m at the front and to both sides is unique The detection range is affected by the follow ing factors Rearfield detection Rearfield detection Ta Security nm Rearfield detection Rearfield detection e Local weather condi tions e Installation site and height e Horizontal and vertical alignment e Direction of movement in the detection zone Range up to 16 m Install
15. NE 3 highly sensitive sen sors In combination with a mirror system and the perfectly matched lens result in a detection angle of 220 degrees The lens and the mirror system receive and bundle the infrared radiation and project it onto the sen sor The sensitivity to movement within the detection zone Is deter mined mainly by the number of lens seg The microprocessor The use of a micro processor to control the Busch Watchdog provides a series of valuable features e Range stabilisation in a variety of weather conditions e Suppression of inad vertent wrong opera tions to ensure that undesirable inadver tent operations due for example to mov ing trees wind etc are largely filtered out e Dazzleproot e g against car headlights and torches ments and their optical design The available range depends on the size of the lens seg ments optical magnifi cation and the electri cal amplification factor The lens system of the Busch Watchdog which is permanently connected to the sen sor housing to provide a good seal for the unit has an exceptionally high resolution for movement detectors The possibility of moni toring backwards beyond the trame without loss of frontal range for installation directly above doors or windows is also unique This is especial ly convenient when leaving the house e Short time pulse e g for staircase timer switches e Precise digital time and dusk se
16. Tomorrow s aspirations Busch Watchdog Manual for Electrical Specialists More security www Busch Jaeger com Del ivered today Contents Technology Applications Operational safety Interference factors Function overview Range Surveillance range Installation Connection and settings Remote control Applications for special devices Busch Watchdog range Busch Watchdog flush mounted range Possible combinations of functions of flush mounted devices for slave unit operation Examples of typical circuits Troubleshooting Technology The new professional class of Busch Watch dogs is an assortment of outdoor movement detectors Optimum detection and the pro fessional lens have long been the trademark of Busch Watchdogs The innovations include features that allow better adjustment improved operation and easier installation Basic principles The Busch Watchdog iS a passive infrared movement detector It registers invisible infrared heat radiation If the registered energy pattern changes as the result of movement a pulse is activated The range depends on the intensity of the infrared radiation and on Its direction of movement The Busch Watchdog is purely a receiver and transmits no signals itself The connection between The detection principle All bodies with internal heat emit infrared radia tion The sensors used in the Busch Watchdogs can detect this infrared radiat
17. and via the parallel ABB Powernet EIB or ABB i bus EIB KNX binary input corresponding mes sages are issued to the room and control panel If the house is left or only a move ment detected in the security zone without previous detection in the remote level only person moves away from the house the two light sources switch in the reverse order At dusk in the direct vicinity of the Watch dog e g when some body goes to the letter box or dustbin only the door entrance lighting Is activated to the control panel in the Interior the outside lighting is switched on Upon request see P 17 remote control the monitoring camera can be activated and signals sent to the room and control panel also in the daytime For additional connec tion images see P 24 25 Busch Watchdog range The entire Busch interior and outside Watchdog range areas as well as vari includes movement ous accessories detectors for outdoor areas and the flush mounted devices for Movement detector Flush mounted devices Busch Watchdog Busch Watchdog Busch Watchdog Busch Watchdog Busch Watchdog 220 AlarmLINE 220 ProfessionalLINE 280 ProfessionalLINE 90 ProfessionalLINE 220 SelectLINE The security The universal The professional The professional Won t be disturbed professional professional for house corners for terraced houses by small animals Movement detector Surface mounted devices accessories
18. ation To ensure that the Busch Watchdog func tions optimally the fol lowing information and installation preconditions or minimum distances must be observed 12 Installation instructions The Busch Watchdog must be mounted on a solid wall since each detector movement has the same effect as a movement of a heat source In the surveil lance zone To optimise detection install the device at an angle to the detection levels A directly ap proaching heat source is not detected as reli ably as one moving across the detection zone Since infrared waves cannot pene trate solid objects make sure that nothing obstructs the line of vision of the Busch Watchdog When specifying the mounting location and height take into ac count the distances to the road and to neigh bouring properties etc to avoid unwanted triggering Every passive infrared movement detector responds to a fast change in local heat radiation For example raindrops on the lens may deflect the heat radiation disturb the local conditions and trigger switching To prevent Inadvertent switching operations the Busch Watchdog should therefore be installed so that It Is protected from rain wind and direct sun light as far as possible The housing of the Busch Watchdog is adequately protected against water spray allowing an outdoor installation without additional water pro tection Installation at a height of 2 5 m
19. h Watchdog is exceeded operation is triggered Sunlight has a high percentage of natural infrared radiation If the sun shines for example onto a bush or a tree in Range fluctuations In extreme weather conditions the size of the detection zone may change High out side temperatures and poor visual conditions due to fog rain or snow can temporarily reduce the range Excessively long ranges are caused by close by sources of extreme heat such as lorries or buses and at very low outside temperatures and good visual conditions It is important here to set the detection range to the required distance during installation by adjusting the angle of the Busch Watchdog the detection zone and this bush or tree moves in the wind this may cause a movement detector to trigger Sunlight reflecting off glass or water a heat ment detector This can be prevented by using surge voltage protectors or a special RC element For further information about this see the trou bleshooting section source cooling down e g a lamp mounted nearby or animals in the detection zone can also trigger detection Mains voltage peaks caused for example by switching inductances such as relays and con tactors on and off can also activate a move sensor and If neces sary by using Busch Watchdog masking strips The automatic range stabilisation of the Busch Watchdog counteracts the effects described above but
20. ion The more dis tinct the radiation in rela tion to the surrounding area i e the colder the outside temperature and the more intensive the radiation of the de tected body the larger the sensor signal the heat source and the Busch Watchdog is the ambient air Under certain circumstances the reception condi tions are influenced by the prevailing weather conditions As a result of the highly intelligent electronics the Busch Watchdog can recog nise this and largely compensates for range fluctuations Detection through obstacles such as glass or vegetation is not possible The Busch Watchdog reacts to large rapid changes in tempera ture Slow temperature changes and constant temperatures such as the cooling of a car engine do not activate the device If a person moves directly towards the sensor the increase in heat intensity is slow and the unit is not therefore activated immediately Where possible the device should therefore be fitted at a right angle to the likely direction of movement to ensure re liable activation Humid air for example fog can reflect the infrared radiation resulting in reduced device sen sitivity Technology a i wiji gt S The optical system The range and detection angle of a movement sensor are determined mainly by its optics i e the arrangement and design of the sensors used and of the lens In the Busch Watchdog 220 ProfessionalLI
21. l auxiliary relay and the out additional contactor relays these relays guarantee high service life of the device Automatic range stabilisation The range normally fluc tuates between 50 and 100 depending on the prevailing ambient conditions The Busch Watchdog recognises the ambient conditions Automatic interfer ence suppression This is another feature made possible by the built in microprocessor of the Busch Watch dog If for example the detector switches on due to sunlight External light protection With the dusk sensor set to dark the Busch Watchdog could be deactivated by a light source torch or car headlights To avoid this situation and therefore increase security the Busch Watchdog leaves its current monitoring function unchanged tor 90 seconds if the light conditions sud denly change A built in microproces sor with intelligent software then controls the internal electronic amplification to reduce weather induced range fluctuations to a mini mum wind and moving bush es the detection logic recognises this and sup presses many of the unwanted operations by adjusting the operating mode Operational safety interference factors Wrong operation The principle of opera tion of a passive infrared movement detector means that its function depends on the physical conditions in the detec tion zone When heat sources move and the response threshold of the Busc
22. lways point down wards after installation otherwise the direction of detection is upwards Movement detectors are not suitable as spe cial burglar alarm sys tems as they do not have the tamper protec tion required for this function Ceiling mounting For installation e g under roof projections canopies and balconies the Busch Watchdogs ProfessionalLINE and AlarmLINE are optimal ly designed The devices can be pre pared for the respec tive mounting position by simply rotating the sensor housing Again the adjustment screws must point downwards after installation Important Observe correct installation height approx 2 5 m Installation in lighting control systems For installation e g in hallways and corridors of administrative build ings it is essential to adapt the surveillance zone to the local condi tions For installation for example in entrance halls and corridors of office buildings note that the best results are obtained with movements across the surveillance zone To bridge downtimes the time should be set as high as possible Installation In principle all Busch Watchdogs can be mounted on ceilings walls or even in corners Wall mounting Busch Watchdog ProtessionalLINE Busch Watchdog 220 AlarmLINE Ceiling mounting Busch Watchdog ProfessionalLINE Busch Watchdog 220 AlarmLINE Corner mounting Busch Watchdog 280 ProfessionalLINE Restricting the
23. range of the security zone Is about six metres to the front and to both sides If someone enters this inner zone from out side the red warning light is activated and a signal applied to an additional potential free output The two signals Alarm mode The alarm mode is intended for monitoring a security zone ata distance of 6 m to the Busch Watchdog 220 AlarmLINE The potential free switch output of the security zone can be combined e g with a monitoring camera The parallel transfer of information and alarm signals to the room and control panel is possible When the house is approached at dusk the lighting is first switched on If the Comfort mode 2 zone operation The Busch Watchdog 220 AlarmLINE per forms in this function like 2 independent movement detectors Depending on the dis tance from the moni tored house 2 differ ent surveillance zones can be evaluated sepa rately For example at a distance of 6 16 m the path lighting Is switched on and if the person further approaches the house lt 6 m the door entrance lighting is activated When the can be cut out sepa rately via the optional infrared service manual transmitter At this 2nd output an additional light can be connected or a signal can be sent area of the security zone is then entered the 2nd switch output and the warning lamp are activated A con nected monitoring camera delivers the video information to the house
24. reactivated Simulated presence This operating mode combines the functions of a movement detector with those of a tradition al dusk switch The connected lighting Is switched on at dusk by approx 22 30 07 23 30 summer time At the end of this permanent light phase the device reverts to normal detec tion Note only 220 AlarmLINE Operation via NC switch only acts on switch out put 1 detection levels 1 4 see P 6 Deactivation Early termination of the 4 hours continuous light and return to oper ating mode that was active before the ON button was pressed Operation The movement detec tor measures the out side light parameters and learns in which season It IS working The internal time basis is then adjusted accord ingly e g extended in autumn winter Note When the short time pulse is set the switch output is cycled 1 s ON and 55 s OFF to control time switches The continuous light has no effect on the 2nd switch contact and the warning lamp only 220 AlarmLINE Note When the short time pulse is set during the continuous light phase the switch output is cycled 1 s ON and 55 s OFF to control time switches The continuous light phase does not act on the 2nd switch contact and the warning lamp only 220 AlarmLINE Remote control The infrared service manual transmitter has been developed espe cially for operation at the customer Additional monitor functions
25. set via the infrared service manual trans mitter are cancelled Applications for special devices In addition to the basic functions the Busch Watchdog Professional offers numerous advan tages in day to day operation Busch Watchdog 220 SelectLINE Ceiling mounted Busch Watchdog 220 SelectLINE Wall mounted Busch Watchdog 220 SelectLINE The particularly narrow On account of its spe disc shaped monitor cial function and area ing zone of the of application the Busch Watchdog Busch Watchdog 220 SelectLINE makes 220 SelectLINE is it attractive for various not equipped with applications in industri rearfield monitoring al and private use Horizontally aligned detection covering a large flat area can pro vide the desired effect of precise spatially lim ited monitoring of prop erties or car parks In contrast a vertical surveillance zone Is suitable with appropri ate installation e g for warehouse aisles at large industrial sites With an installation height of e g 1 5 m horizontally aligned there is an approx 1 metre high area outside the detection zone So small an mals are not detected but humans are Applications for special devices The security provided by the Busch Watchdog 220 AlarmLINE is unsurpassed The light gives anyone approach ing the house the impression that they have been seen This is made possible with the additional security zone The
26. tches on for the set period min 1 min for time settings 6800 xxx 104 M less than 1 min exception short time pulse IL 6805 U Setting of short time pulse IL 6813 101 NO switch Switches on for the set period exception short time pulse M and heating air conditioning and ventilation control 6805 U Setting of short time pulseTLand daytime operation 4 6593 U 6810 21x 101 NO switch Switches on for 80 s independently of ambient brightness 6550 U 101 6805 U 160 s as addition of main and slave units 6800 xxx 104 M NO switch Switching for the set period In the operating mode Soft off at the end of the switch off delay time of 60 s the light is dimmed and switched off 6805 U Setting of short time pulse IL 6813 101 NO switch Constant light control for the set time Exception short time pulse IL 6805 U Setting of short time pulse IL and daytime operation 4 6805 U 6810 21x 101 6800 xxx 104 M 6813 101 Retriggering respective main unit to extend surveillance zone Slave unit function via interruption of operational voltage gt 2 s 2 With longer operation gt 1 s 22 Examples of typical circuits for surface mounted units Busch Watchdog switched on through NC switch If the power supply of the Busch Watchdog is intermittently interrupt ed in standby mode and then reconnected the lights are switched Busch Watchdog on automatically for the set delay time switch LS16A Function selection 1
27. the switch is operated the Watchdog is auto matically switched on for the specified time for example for stair case time switches Extension of surveil lance zone via several slave units 6805 U in combination with main unit 6401 U 102 Busch Universal Relay Unit 6804 U 101 MOS Fet Unit or 6593 U Busch Univer sal Central Dimmer Note Actuate NC switch min 2 Note The minimum load is added if several units are switched parallel e g 120 W VA for 2 units Note For illuminated switch es a separate N is required Neutral conductor is required for 6401 U 102 Busch Universal Relay Unit Note In combination with the Busch Universal Central Dimmer 6593 U in operating mode 4 Soft OFF the light is dimmed within 60 s and then switches off In combination with the Busch Universal Central Dimmer 6593 U in operating mode 4 Soft OFF the light is dimmed within 60 s and then switches off Troubleshooting In event of failure this table shows where the problem might be if something malfunc tions Fault Light does not come on Automatic undesired switching Possible cause Fault remedy Switch on supply voltage check supply voltage Light is always on Lens obscured clean lens or remove masking strip No detection adjust detection zone e Too bright readjust dusk sensor Replace faulty lamp Switching on after mains failure wait
28. tion for windows and doors up to the wall of the house even in case of installation directly above doors and win dows is provided by the integrated rearfield detection With its many mounting and alignment options the Busch Watchdog can be optimally adapted to the local conditions Levels 1 and 2 cover remote surveillance and ensure seamless detection when the surveillance zone Is entered from the outside Level 4 covers the rearfield detection which is activated when the front door is opened from the inside Applications This table lists only You will also find the some of the many appropriate version possible applications for your specific ap plication Application Corridors hallways Animal path in Outdoor areas Hallways corridors areas cellars changing outdoor areas terraces cellars libraries rooms rest rooms storage rooms loading ramps offices loading bays showrooms outdoor areas sale terraces Private house Hotels Sports facilities Multi storey car parks basement garages Transportation companies Hospitals old people s homes Trade fairs exhibitions High shelf warehouses Operational safety interference factors connected installation work only tested high capacity relays are used Beside the high switching capacity of up to 3 680 W VA with The high capacity relay To allow the connection of high loads without needing an additiona
29. tting e Selectable simulated presence e Continuous light through NC switch e Intelligent alarm func tion separate surveil lance zone The following factors should be taken into account at the planning stage The most frequent direction of movement of an object with respect to the mount ing optimally move ment at an angle to the detection levels see Fig P 4 Mounting height 2 5 m this height ensures an optimum monitoring function and forms the basis of the range specifications Self test A further advantage of the microprocessor used in the Busch Watchdog 220 280 ProfessionalLINE and Busch Watchdog 220 AlarmLINE is its built in test function Every time the supply voltage is connected or a restart occurs an inter nal test program carries out a complete self test If this test is positive the Busch Watchdog switches itself on for at least approx one minute or the set delay time This confirms that the device is fully opera tional Technology Each Busch Watchdog The diagrams show the of the new Professional various areas of use class has been devel oped for a particular area of use The various detection levels To fully cover the sur veillance zone the Fresnel lens splits the zone into several overlapping levels Level 3 covers close range detection to pre vent undetected entry of the surveillance zone close to the wall Rearfield detection Additional protec
30. ut is limited to max 3 mins The warning lamp if activated via infrared service Manual trans mitter has a fixed delay time of 30 s Comfort mode only 220 AlarmLINE In all sensitivity level set tings the Busch Watch dog 220 AlarmLINE works in comfort mode and serves to switch 2 different illumination Zones normal detection levels 1 4 see P 6 is switch ed depending on bright ness Tip By activating the func tion Day operation for alarm evaluation via the infrared service manual transmitter see P 17 the security zone can also be monitored during the day Remote control With the two infrared manual transmitters or an additional button the most important functions of the Busch Watchdog can be acti This also applies for the simulation of presence in which the Busch Watchdog switches to continuous light at dusk and later to normal vated 7 BUSCH JAEGER BUSCH JAEGER operation Via NC switch manual operation By means of an NC switch in the supply line of the movement detector the light can be switched on for the duration of the delay time set at the unit If during this time the movement detector detects movement the connected lamp remains switched on Via infrared manual transmitter Continuous light If this function is acti vated the relay output switches permanently for 4 hours After this period the previous operating mode is auto matically