1. DO NOT operate fan in the presence of explosive and or flammable fumes DO NOT place fan or any parts near an open flame cooking or other heating appliances DO NOT operate any appliance with a damaged cord or plug after the appliance malfunctions or has been dropped or damaged in any manner 10 To disconnect grip the plug and pull from wall outlet Never pull on the cord 11 To protect against electrical shock do not immerse the fan plug or cord in water or spray with liquids 12 DO NOT put fan in a damp place or where humidity is high such as a bathroom 13 DO NOT use near curtains plants window treatments et cetera 14 This appliance has a grounded three prong plug and is suitable for grounded receptacle use only An adaptor is available from your local hardware store for connecting three prong grounding type plugs to two slot receptacles The adapter must be properly grounded DO NOT attempt to defeat the purpose of this safety feature 15 Improper installation may result in a risk of fire electrical shock or personal injury 16 ALWAYS use on a dry surface 17 Use fan only for intended use 18 This product is intended for household use only and not for commercial or industrial use ASSEMBLY INSTRUCTIONS CON OOS aN Table amp Desk Fan No assembly required Please skip to the Important Saftey Instructions below Floor Fan 1 Make sure you are familiar with the 3 components Motor Cage Assembly
2. CS 9 d FAN COMP ANY ep hair Oscillating Floor Model Fan Service Manual Section VI Owner s Manual gf a ig ag ga j Fi e a age i By dh oglau AD pA vs IX 6 0 761 Corporate Center Dr Pomona CA 91746 909 689 1477 800 498 8482 FILE NAME SM_ZEPHAIR FLOOR FAN RAS 4 13 04 e Oscillating Floor TABLEModel Fan OwNeER S MANUAL IX 6 1 761 Corporate Center Dr e Pomona CA 91746 909 689 1477 800 498 8482 FILE NAME SM ZEPHAIR FLOOR FAN RAS 4 13 04 Eege FACTORY SERVICE TECHNICAL LIBRARY Leg AS FAN COMPANY KN SERVICE MANUAL CAUTION Read and follow all instructions before WARNING To reduce the risk of fire or electric shock operating the fan Do not use the fan if any part is do not use this fan with any solid state speed control damaged or missing device READ amp SAVE THESE INSTRUCTIONS SAFETY FIRST IMPORTANT SAFETY INSTRUCTIONS Never insert fingers or any other objects through the cage guard when the fan is in operation Close supervision is necessary when any appliance is used by or near children Disconnect the fan when moving from one location to another Disconnect the fan when removing grill guard for cleaning servicing maintenance and before moving to another location Be sure the fan is on a stable flat surface when in operation DO NOT use the table fan in windows Rain and moisture may create an electrical hazard
3. Pipe Assembly and Base Assembly ei a 2 Lay the Motor Cage Assembly on a flat protected surface NWN y face down i 3 Take the Pipe Assembly and make sure that the collars on Eer I WAY both ends are pulled in enough to expose the notch in the Sm pipe 4 Take the cord from the Motor Cage Assembly and feed it through the pipe both ends are the same Make sure the plug clears the end of the pipe 5 Align the pipe collar onto the neck post of the Motor Cage Assembly sliding the tab of the motor cage into the notch of Us the pipe 6 Thread the collar and turn the until it is snug d NOTCH 7 Lay the base of the fan on it s side close to the pipe The x Step 5 IX 6 2 Assembly instructions Continued 761 Corporate Center Dr Pomona CA 91746 909 689 1477 800 498 8482 FILE NAME SM_ZEPHAIR FLOOR FAN RAS 4 13 04 Ze 3 FACTORY SERVICE TECHNICAL LIBRARY GPa FAN COMPANY Lephair SERVICE MANUAL Assembly instructions Continued male pin connector is on the neck of the base note that one side has a locking tooth 8 Assure that the latch and locking tooth are matched up and plug the wire from the pipe into the fan base Move the collar away from the end and slide the pipe onto the fan base but do not tighten the collar yet 9 With one hand hold the handle of the motor cage and with the other hold the neck of the base and tilt the fan up to a standing position 10 Align the tab from th
4. the Casablanca logo is not rotated then place washer over screw and tighten nut as shown above Do not plug fan into an electrical outlet until it has been fully reassembled PRODUCT SPECIFICATIONS Table Fan Floor Fan Desk Fan Table Fan Floor Fan Desk Fan Overall Height 21 54 16 5 Oscillating Sweep Angle 902 90 55 Overall Width 17 18 12 5 Overall Depth 11 hie LL Sa 8 Horizontal Angle 20 20 20 Safety Cage Diameter 15 ze Ki Blade Diameter 14 Tei 14 1 10 44 Electrical Cord 9 9 cloth covered 9 9 cloth covered 7 cloth covered Weight 24 lbs 50 lbs 20 Ibs grounded plug grounded plug grounded plug Motor RPM Low 600 600 710 Motor RPM Medium 800 800 1010 Warranty Lifetime Motor Lifetime Motor Lifetime Motor Motor RPM High 1200 1200 1310 1 year parts amp labor 1 year parts amp labor 1 year parts amp labor WARRANTY STAPLE PROOF OF PURCHASE TO THIS PAGE KEEP FOR FUTURE REFERENCE If purchased from our authorized dealer this portable fan is warranted to the original purchaser by Casablanca Fan Company against defects in materials and workmanship for the following Lifetime motor warranty 1 year Parts and Labor During the warranty period we repair or at our option replace at no charge a defective product HOW TO OBTAIN SERVICE CONTACT YOUR DEALER FOR THE NAME OF THE NEAREST SERVICE CENTER or CALL TOLL FREE 1 888 227 2178 Do not return this portable fan without ap
5. e base to the notch in the pipe Thread and tighten the collar for the base of the fan tighten completely 11 Set the floor fan up where the cord will not be in a traffic area or tripped on Also make sure the oscillation movement of the cage is not impeded in any way Step 9 Step 10 Step 8 OPERATING INSTRUCTIONS 1 Place the fan on a safe flat surface where it cannot fall or be pulled by the cord 2 Plug the fan into a grounded outlet 3 To set the horizontal direction of airflow hold the fan housing neck in one hand make sure the oscillating Knob is in the up position and then turn the cage left or right 4 To control the vertical direction of airflow grip the handle on top of the fan tightly and loosen the wing nut on the side of the fan housing neck Adjust to the desired angle and tighten the wing nut 5 Tomake the fan oscillate push down on the oscillating knob located on the top of the fan housing near the handle To stop the fan from oscillating pull up on the oscillating knob IX 6 3 Operationg Instructions Continued 761 Corporate Center Dr Pomona CA 91746 909 689 1477 800 498 8482 FILE NAME SM ZEPHAIR FLOOR FAN RAS 4 13 04 FACTORY SERVICE TECHNICAL LIBRARY KT SERVICE MANUAL Operationg Instructions Continued FOR TABLE amp DESK FOR FLOOR FAN 6a To sleect a speed on the table model move the switch lever located on the base of the fan from OFF to the d
6. esired speed setting of 1 low 2 medium or 3 high 6b To select a speed on the floor model move the switch knob located on the back of the motor housing from OFF to the desired speed setting of 1 low 2 medium or 3 high Table amp Floor Fan Only 7 OPTIONAL To store the excess cord unplug the fan from the wall socket and gently lay the fan on its side making sure that the cage and motor are properly supported To remove the base bottom unscrew all of the screws Remove the cord restraint screw Gently pull the cord through the bottom rubber bushing assuring it remains in place and through the cord restraint until you have the desired RUBBER length If the rubber bushing in the base has BUSHING CORD come loose reinstall it into the base of the RESTRAINT fan Re align the cord restraint to the proper position to reattach it to the base with the screw Feed the excess cord into the neck of the base For the table fan keep it away from the speed switch assembly Replace the base bottom aligning the screw holes and reinstall the screws assuring that no wires or cord are pinched CORD oe RESTRAINT SWITCH ASSEMBLY SCREW USER MAINTENANCE amp CLEANING This fan is permanently lubricated and will not require additional lubrication oil for the life of the fan This appliance requires little maintenance and contains no user serviceable parts Do not try to fix it yourself Call toll free 1 888 227 2178 a
7. nd ask a technician for the closest Authorized Casablanca Service Center or visit our web site at www CasablancaFanCo com click on Dealers then follow the directions making sure to select Service Center in option 3 TO CLEAN Before cleaning turn off the fan and unplug from electrical outlet Wipe off excess dust with a lint free cloth To ensure adequate air circulation to the motor keep vents located at the rear of the motor housing free from dust accumulation A vacuum cleaner hose can be used to clear these vents Do not immerse the fan in water or any other liquid WARNING DO NOT OPERATE FAN WHILE CAGE IS REMOVED FOR CLEANING IX 6 4 User Maintenance amp Cleaning Continued 761 Corporate Center Dr e Pomona CA 91746 909 689 1477 800 498 8482 FILE NAME SM_ZEPHAIR FLOOR FAN RAS 4 13 04 FACTORY SERVICE TECHNICAL LIBRARY Zephair SERVICE MANUAL User Maintenance amp Cleaning Continued CLEANING GRILL AND BLADES Turn the fan off and unplug from the wall socket Carefully remove the 8 nuts and washers from the back of the grille and set aside in a safe place The cage and blades may be cleaned with mild soap and water Use a soft slightly damp cloth to wipe the remaining fan parts Do not allow water or any other liquid to get into the motor housing or base Reassemble the fan after the cage and blades have dried completely To do So align the screws to the holes in the back assuring
8. o state IX 6 5 761 Corporate Center Dr e Pomona CA 91746 909 689 1477 800 498 8482 FILE NAME SM ZEPHAIR FLOOR FAN RAS 4 13 04
9. proval from Casablanca Fan Company Should it become necessary to return your fan to an authorized Casablanca Service Center make sure it is properly packaged to avoid in transit damage which is not covered by this warranty This warranty does not apply if the product has been damaged by improper installation neglect accident misuse exposure to extremes of heat of humidity or as a result of service or modification by other than an authorized Casablanca service center All costs of installing removing and reinstalling the product are the responsibility of the owner Warranty motor repairs must come back to the factory for replacement Casablanca will not pay for shipping charges incurred in sending the defective product from the customer to Casablanca Fan Co but will pay for return UPS shipment No other expressed warranty is given The repair or replacement of a product is your exclusive remedy Any implied warranty of merchantability or fitness is limited to the duration of this written warranty Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you In no event shall Casablanca be liable for consequential or incidental damages Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state t

Download Pdf Manuals

image

Related Search

Related Contents

Share the experience  MESSENGER-SOC-PIPE End  User`s manual  Gigabyte GA-890XA-UD3 motherboard  MANEJO DE GPS 1. Acorde a la explicación, realizar lo siguiente: a  EVGA 02G-P4-2680-KR NVIDIA GeForce GTX 680 2GB graphics card  Sonic Farm Creamer/Creamer Plus USER MANUAL  CNC 800M -OEM - (eng)  Whirlpool LE8650XW User's Manual  Rexel Joy  