1. REDIT PULSE SERIAL PULSE F SERIAL DATA OUT INHIBIT LINE CG MICROCONTROLLER MICROCONTROLLER FROM We PAGE 1 26 Part 1 Operation Manual Rev 03 2004 eh CashCod MSM BackLoad Bill Validator Operation and Service Manual SWITCH SETTINGS The switches are located at the CPU board The MSM bill validator operates in two basic modes Validation Mode and Service Mode Validation Mode This is the mode for normal operation If a red status light is illuminated it indicates that the validator is not ready to accept currency Service Mode This is the mode for programming and testing the CashCode Bill Validator A set of 8 DIP switches SW1 defines the settings and programs the Bill Validator to recognize and validate different denominations But for some interface types MDB CCS two last positions define type and parameter of interface A set of 4 DIP switches SW1 defines the settings of interface type For a complete explanation of switch description please see the software User s Guide enclosed to each bill validator and available at www cashcode com Rev 03 2004 Part 1 Operation Manual PAGE 1 27 D CashCod MSM BackLoad Bill Validator Operation and Service Manual MAINTENANCE AND SERVICE Ca
2. During normal operation some dirt from bills can be transferred to the walls of the bill path and to the sensors This may be a reason for reducing acceptance rate It is recommended to clean the surface of the sensors with a soft cloth Isopropyl alcohol may be used to remove the dirt PAGE 1 30 Part 1 Operation Manual Rev 03 2004 eh CashCod MSM BackLoad Bill Validator Operation and Service Manual Access to the switches and to the Memory stick 1 Lift the cover from the CPU board Switches and Memory stick are placed on the CPU board to install the cover CashCode Memory stick The location of switches and Memory stick on CPU board may vary Rev 03 2004 Part 1 Operation Manual PAGE 1 31 D CashCod MSM BackLoad Bill Validator Operation and Service Manual SOFTWARE UPDATES To ensure the proper operation of the MSM Bill Validator software updates can be ordered according to the original MSM part number The MSM Bill Validator is shipped with pre installed software according to a user s ordered specifications Download procedure for a single download Memory Card Step 1 Turn Power OFF Step 2 Remove Cassette and open CPU cover Step 3 Remove the Dummy Card or Memory stick from the Memory stick slot of the CPU Board Step 4 Insert the new CashCode Memory stick into the Memory stick slot of the CPU Board Step 5 Close cover and insert cassette Step 6 Turn Power ON and wait until the d
3. SOLOW Laos 2107070 2210000 31843 avoa 137238 DE para HS 144 H 6v0S0r0 avo AdUNIN ENEE 91140 295 SNF INT 10 0210060 31473 LE0e070 avoa JILA LAN293S99 JIVISJINI asides cx S DSN3S 271 NOV L3N99 83S 1Nd8SI3 Se01070 O VDE Ndo 0210050 S200E070 Gavod OIL ANSVW 9900020 ao low HOI Part 1 Operation Manual PAGE 1 11 Rev 03 2004 eh CashCod MSM BackLoad Bill Validator Operation and Service Manual CHOOSING MSM FEATURES AND PART NUMBERS Bill Validator Following data is required to make a correct choice of the bill validator currency country protocol type interface bezel style style of the cassette regular or high security locks on the cassette indoor or outdoor application coated boards are used for outdoor application left side interface connector this option is available for MDB protocol only There is a special software program for choosing part numbers This program can be found at www cashcode com program name is CONFIGURATOR exe Currency Please refer to the chart below to find your country Only countries with single width currencies are included in the list However for some countries with multi width currencies the MSM can be used
4. typically for minor denominations For the multi width currencies please refer to CashCode MSM BackLoad bill validator If you currency is not presented on the chart do not hesitate to contact CashCode Customer Service Please remember the path width for the bill validator of your selection when choosing the cassette the path width must be equal PAGE 1 12 Part 1 Operation Manual Rev 03 2004 QD CashCod MSM BackLoad Bill Validator Operation and Service Manual Protocol Choice of 5 interfaces is available For more detailed description see chart Interface Connection Bezel style Three different styles of bezel are currently available Standard plastic bezel This bezel can be used for both the installations of STACKER UP and STACKER DOWN positions The bezel has an inlet for the bill and the status light red for BUSY and green for READY The status light also provides a diagnostic for service personnel The bezel has 2 designated places where customized stickers gt can be applied Sticker sizes are WxH 35x12 mm and Ad 76x48 mm SS Plastic Bezel shown as STACKER UP The Metal bezel was developed for vandal proof applications It is not sensitive to external impacts It also has the path of special shape to be coin protected insertion of coin cannot block the path and make bill validator disabled The metal bezel has an additional transport motor inside that needs more pow
5. the Bill Validator is powered on The Memory stick must be present at all times for the Bill Validator to operate 2 New software can be ordered with a multi download Memory stick The multi download Memory stick allows the operation of the MSM bill validator without the Memory Card Thus the Memory stick can be used for updating the next Bill Validator depending on the number of licenses ordered Typically a multi download Memory stick is issued for a limited number of downloads and therefore the number of licenses required must be defined in the user s order 3 A special Memory stick can be ordered which allows the download of new software through the interface connector After the download the Memory stick must be present in the Bill Validator at all times If the host controller supports the CCNET interface then the download can be done via the host controller and local network Other interfaces do not support this download feature Downloads in this case can be completed with any personal computer PC or laptop and a CashCode adapter The Validator must be temporarily disconnected from the host controller Instructions for Memory stick replacement and software updates can be found in the chapter named SOFTWARE UPDATES Rev 03 2004 Part 1 Operation Manual PAGE 1 17 D CashCod MSM BackLoad Bill Validator Operation and Service Manual Final part numbers for the MSM bill validator consist of two parts a hardware p
6. the software is suitable ON RED Memory stick to the Bill Validator type 2 Insert correct type of CashCode Memory stick 4 GREEN FLASHES Memory stick is not Properly insert the Memory stick ON RED inserted 5 GREEN FLASHES Wrong type of Memory Insert correct type of CashCode ON RED stick Memory stick 6 GREEN FLASHES ON RED Failure during download 1 Turn POWER OFF remove and insert the Memory stick again turn POWER ON 2 7 GREEN FLASHES Operation ERROR of 1 Turn POWER OFF remove and ON RED Memory stick Interface insert the Memory stick again turn POWER ON 2 Replace Memory stick with new one Rev 03 2004 Part 1 Operation Manual PAGE 1 33 D CashCod MSM BackLoad Bill Validator Operation and Service Manual TROUBLESHOOTING CashCode MSM Bill Validator is equipped with a self diagnostic feature to ad in repair and maintenance When the power to the Bill Validator is turned ON the Bill Validator begins its self diagnostic operation If the self diagnostic test is passed then the status light will turn green If an error is detected then the status light on the front of the Bill Validator will blink red The number of times the red light flashes on the Bill Validator is an indication of a specific problem or malfunction A detailed list of these errors and corrective action is provided in the Diagnostics section to follow OPERATION MODE DIAGNOSTICS Number
7. 25 Case 5201009 from previous assembly Gap 5207006 lt from previous assembly Cam Lock 5110008 from previous assembly Locking mechanism installation 1 Disassemble the metal lock and install it on the Locking Device Assembly as shown The cam of the lock is shown in LOCKED position Perform this step if the lock is not installed on the locking device 1 IS parts of Lock 043 Racking Device Assembly 0100336 Lock 043 8206926 PAGE 1 20 Part 1 Operation Manual Rev 03 2004 QD CashCod MSM BackLoad Bill Validator Operation and Service Manual 2 Insert the key into the lock and turn it to the OPENED position Insert two tabs of the locking device into the slots in the cassette Rotate the locking mechanism and insert two other tabs of the locking device into the corresponding slots in the cassette Turn the key to the LOCKED position Nylon Push Rivet SR 3055B 8102003 Step 2 Step 3 3 Secure the locking mechanism with 4 plastic push rivets Rev 03 2004 Part 1 Operation Manual PAGE 1 21 D CashCod MSM BackLoad Bill Validator Operation and Service Manual INTERFACE CONNECTION The BackLoad Bill Validator MSM has the flexibility to offer five different hardware interface options Type 1 Opto lsolated 24 Volt DC AC MDB Interface Using Adapters Single Price Interface and Host Intelligence Interface Type 2 Opto lsolate
8. Interface Connectors left side optional MDB interface only Rev 03 2004 Part 1 Operation Manual PAGE 1 9 D CashCod MSM BackLoad Bill Validator Operation and Service Manual Metal Up Bezel Metal Down Bezel 38 8 1528 T CASSETTE PAGE 1 10 Part 1 Operation Manual Rev 03 2004 Manual ice lidator Operation and Servi ill Va MSM BackLoad B JCashCod lt oc O lt a O oc sl lt oc LI Z LLI O BG0S070 Daag SAIS 62100 0 SOLOW 2332139158 KEN 3189 BX SOLOW dINVLS le EIER SN LSDdSNVEL TK esosovo avoga Aida 4210080 37499 1x Da 33NYXLNI cavod AJLI SHDSN3S ILL3NIWWA Ave dS RITHSATN 9201070 Swai NdI 21060p0 1x d0LVANLE SOLOWI 2G000 0 8UASNVAl 210050 ECK Ix
9. M with the left side connector This option is available for MDB interface only Following customer s needs CashCode developed several styles of the front bezel The customer may choose from standard plastic bezel or the metal bezel with vandal proof features Operating mode can be chosen with DIP switches located on CPU board Rev 03 2004 Part 1 Operation Manual PAGE 1 5 D CashCod MSM BackLoad Bill Validator Operation and Service Manual STACKER UP SK STACKER DOWN The MSM bill validator operates with the Lockable Removable cassette These cassettes are not exactly the same that were used with the previous CashCode ST and SM bill validators All accepted bills are stored in the cassette as a stack The cassette cover can be locked with locks of different styles limiting access to the stored bills Cassettes are not differ in the width of the bill path Widths are available 62 77mm The maximum length of the bill that can be stored into the cassette is 160 mm Depending of available space in the machine the cassette of proper size can be chosen The cassettes are available in following sizes 300 500 1000 bills Please keep in mind than when the cassette capacity is mentioned it means the space inside the cassette and how many brand new bills can be stores in this space Street grade bills require more space and as a result fewer bills may be stored For additional security the casset
10. QD CashCod MSM BackLoad Bill Validator Operation and Service Manual CashCode MSM BackLoad Bill Validator Operation and Service Manual Part 1 Operation Manual Rev 03 2004 Part 1 Operation Manual PAGE 1 1 D CashCod MSM BackLoad Bill Validator Operation and Service Manual CONTENTS INTRODUCTION sess eect ca act cece us iae waana dakika e Ea suku Haka Eaire E pean ses 3 PRODUCT Ee teeta eee tate EEN 4 R Ee 9 GENERAL WIRING DIR GRANT ed dd na at 11 CHOOSING MSM FEATURES AND PART NUMBERS ceceeeeeeeeeeeeeeeeeeeeeeeeteees 12 ot I Na E 12 SSSR a E e ASAS Su UE 12 enke 13 Bi ii iwa 13 Style of Cassette aa 14 Indoor or outdoor application iia 14 Left side interface connector ss 14 MM SUN a E AA 15 Sec rity feat reS SE eege 15 Memory Stick and software update options 17 INSTALLATION e e E 19 Bill validator installation BE 19 ai AA Eegenen 20 Metal lock installation SE 20 Locking mechanism ITS AMADEUS suet lt ebcaeesiccdtbeacoceedhdine ycedustecases 20 INTERFACE CONNECTION EEN 22 IERT 25 SWITCH SETTINGS cd to ue 27 MAINTENANCE AND SERVICE 5 85 ein Airness te en ade 28 Cassette removal and MAS LAM iOnLss se een nn mes done 28 ACCESS to the Dill PA EE 30 Access to the switches and to the Memory stick 31 SOFTWARE BR KE 32 Download procedure for a single download Memory Card 32 Download procedure for the multi download Smart Stick 32 Download procedure via interface Connector ue 32
11. SOFTWARE UPDATE DIAGNOSTICS ege ann attenante 33 TROUBLESHOOTING sirridir ea ges eased cet ed eta ede a den dan 34 OPERATION MODE DIAGNOST ICS rac 2 nina eddy 34 PAGE 1 2 Part 1 Operation Manual Rev 03 2004 eh CashCod MSM BackLoad Bill Validator Operation and Service Manual INTRODUCTION The scope of this document is to provide full and clear information about the MSM series the next generation of CashCode backload bill validators This document will be useful for those whose needs are Development of new equipment with the MSM bill validator Choice of the MSM bill validator part number Installation of the MSM bill validator Maintenance and service for the MSM bill validator Repair of the MSM bill validator The Manual consists of two parts part 1 Operation and Service Manual and part 2 Repair Manual Rev 03 2004 Part 1 Operation Manual PAGE 1 3 D CashCod MSM BackLoad Bill Validator Operation and Service Manual PRODUCT OVERVIEW The CashCode MSM bill validator was designed for on door installation It means that typically the MSM bill validator is installed on the front door or the front panel of the machine from inside Access to the cassette is from the rear side of the validator service personnel has to open the front door to be able to replace the cassette and to collect money The MSM bill validator consists of two main parts the bill validator itself and the lockab
12. art number and software part number Example MSM 2005 US7712 l Software part number Hardware part number The Hardware part number reflects the contents of the Bill Validator The Software part number reflects country currency and communication protocol The cassette part number can be picked at the page 17 Typically customer needs to order more cassettes than bill validators empty cassettes may be required for replacement during money collection PAGE 1 18 Part 1 Operation Manual Rev 03 2004 QD CashCod MSM BackLoad Bill Validator Operation and Service Manual INSTALLATION Bill validator installation The MSM bill validator is placed on the front door or panel of the machine from inside The front door must have a rectangular cutout and four threaded studs as per picture below _y cut out area Zz Ve i 4 threaded studs 8 32 hight 0 5 N Fr Du A gt location of treaded studs f COLE Cr CITT Es L d For harness connection please refer to the next part Rev 03 2004 Part 1 Operation Manual PAGE 1 19 D CashCod MSM BackLoad Bill Validator Operation and Service Manual Cassettes Metal lock installation 1 Open the cassette cover Remove screw from the plastic handle at the cassette cover 2 Disassemble the metal lock and install it on the cassette cover as shown below Lock 042 82069
13. d 12 Volt DC Isolated Pulse Interface Type 3 TTL level 12 Volt DC CCS Interface Type 4 RS232 levels 12 Volt DC CCNET single slave mode or ID 003 Type 5 TTL level 12 Volt DC CCNET single slave mode or ID 003 For detailed interface descriptions please refer to the corresponding Interface Description Manual The manual may be downloaded from the CashCode website at www cashcode com The type of interface hardware depends on CPU board Opto isolated version Type1 CPU Board 0401018 Pin Assignment cable connector 1357 ap 2468 Molex Part 15 04 5084 1 psc 50 57 9304 2 psc 16 02 0086 8 psc Signal descriptions TERMINAL SIGNAL FUNCTION ACTIVITY 1 DC AC POWER RET POWER 2 34V DC 24V AC POWER 3 GROUND GROUND 4 ADDITIONAL OUTPUT AUXILIARY OUTPUT LOW 5 MASTER RECEIVE Ga ue HIGH LOW 6 ADDITIONAL INPUT AUXILIARY INPUT HIGH COMMUNICATIONS 7 COMMON r MASTER TRANSMIT 8 MASTER TRANSMIT ee HIGH LOW The additional circuits ADDITIONAL OUTPUT ADDITIONAL INPUT are used for control of adapters When used in the external equipment supporting the Single Price Interface the Back Load Bill Validator must be connected with Single Price Interface Adapter OPT AD SP PAGE 1 22 Part 1 Operation Manual Rev 03 2004 D CashCod MSM BackLoad Bill Validator Operation and Service Manual When used in the external
14. equipment supporting the Host Intelligence Interface the Bill Acceptor must be connected with Host Intelligence Interface Adapter OPT AD EX Isolated Pulse Interface Type2 CPU Board 0401017 Assignment cable connector 1 5 2 6 Molex Part 15 04 5064 1 psc 50 57 9303 2 psc 16 02 0096 6 psc Signal descriptions TERMINAL SIGNAL FUNCTION ACTIVITY 1 12 V DC Power Power Supply 2 Ground Power Supply 3 Pulse Output 1 Pulse Signal 4 Pulse Output 2 Pulse Signal Wa esenee 5 Inhibit Line Enable Disable Current Presence is 6 Inhibit Line Accept Bill Enable Accept Bill CCS CCNET and ID 003 Interfaces Type3 Type5 CPU Board 0401017 Assignment cable connector 9 18 10 AMP Part 102398 7 1 psc 102536 7 1 psc 102681 4 1 psc Rev 03 2004 Part 1 Operation Manual PAGE 1 23 S CashCod Signal descriptions MSM BackLoad Bill Validator Operation and Service Manual TERMINAL SIGNAL FUNCTION ACTIVITY 1 Credit Pulse Pulse Signal NIP Interface output Low Availability to transfer a status 2 Interrupt message Ginet Low 3 Serial Pulse Select Interface type input High Low 4 Ground Signal Ground V 5 Serial Data Output An eight bit status message output High Low 6 No
15. er consumption The metal bezel has one status light that can be red or green Customized sticker 76x48 mm can be applied on the bezel Two different bezel configurations are available for STACKER UP and for STACKER DOWN installation Metal Bezel STACKER UP Metal Bezel STACKER DOWN Rev 03 2004 Part 1 Operation Manual PAGE 1 13 D CashCod MSM BackLoad Bill Validator Operation and Service Manual Style of Cassette The MSM bill validator can operate with the cassette that is equipped with the high security locks The MSM bill validator must have an additional bracket gaming bracket to be able to lock this cassette gaming Rat Indoor or outdoor application The MSM bill validator can be ordered with all boards coated for outdoor applications Left side interface connector The MSM bill validator with MDB interface 24 V can be ordered with the interface connector at the left side This option requires an alternative CPU board m Connector at the left side PAGE 1 14 Part 1 Operation Manual Rev 03 2004 eh CashCod MSM BackLoad Bill Validator Operation and Service Manual Cassette Cassettes for MSM bill validator have the following options capacity of the cassette There are 3 sizes 300 500 1000 bills security features Up to 2 security locks are available The chart of possible cassettes is available at the end of this part Security features The cassette co
16. er outlet AC 100 250V Step 4 From the computer run the latest software version of the MSM exe program Step 5 Follow the instructions displayed on the computer screen PAGE 1 32 Part 1 Operation Manual Rev 03 2004 S CashCod MSM BackLoad Bill Validator Operation and Service Manual Step 6 After completing step 5 disconnect the CashCode Adaptor a from the power outlet b from the Bill Validator and c from the Computer Step 7 Connect the interface connector to the Bill Validator Step 8 Turn power ON SOFTWARE UPDATE DIAGNOSTICS Normally the download process will be accompanied by a blinking red green status light for about 1 minute If the download has competed successfully the status light will turn green Should the download be unsuccessful the status light will turn red but short green flashes of light will alternate with a long red light green flashes on red The following table lists possible errors which may take place during a download STATUS OF DIAGNOSTIC LIGHT ERROR DESCRIPTION FAULT HANDLING 1 GREEN FLASHES ON RED External interface ERROR in CCNET Verify that software is suitable for CCNET download Download mode 2 Repeat procedure 2 GREEN FLASHES Memory stick CRC 1 Turn POWER OFF remove and ON RED ERROR insert the Memory stick again turn POWER ON 2 Replace Memory stick with the new one 3 GREEN FLASHES Incorrect data in 1 Verify that
17. ev 03 2004 Part 1 Operation Manual PAGE 1 35 D CashCod MSM BackLoad Bill Validator Operation and Service Manual TECHNICAL SUPPORT CashCode Corporate Headquarters CashCode Company Inc 553 Basaltic Road Concord Ontario Canada L4K 4W8 Phone 1 800 584 2633 1 905 303 8874 Fax 1 800 593 2633 1 905 303 8875 E mail support cashcode com Website www cashcode com PAGE 1 36 Part 1 Operation Manual Rev 03 2004
18. host controller available in CCNET only Power supply voltage 12VDC 1V 24 V AC or 15 42 5 V DC Current consumption 12 V DC operating mode E 2A 12 EI e 0 2 A 24 V AC or 15 42 5 V DC operating mode max 1A 24 V AC or 15 42 5 V DC Sandy menant 0 1 A Power consumption W fe Ee EEN 2 Rev 03 2004 Part 1 Operation Manual PAGE 1 7 D CashCod MSM BackLoad Bill Validator Operation and Service Manual Validation mode Environmental Operating temperature 12 V DC 0 C to 50 C 24 V AC or 15 42 5 V DC 18 C to 60 C Storage temperature 30 C to 60 C Humidity non condensing 30 90 RH Validation he ae EE 750 000 cycles Weight Of Ee E EEN 1 7 kg with plastic bezel Weight of Cassette empty 300 0 96 kg PAGE 1 8 Part 1 Operation Manual Rev 03 2004 eh CashCod MSM BackLoad Bill Validator Operation and Service Manual DIMENSIONS 271 7 10 70 118 046 1151069 no 2 S 2 EI o E E E o 9 o S E S E Interface Connectors cable portion left side optional MDB interface only Interface Connectors cable portion right side
19. le removable cassette The MSM bill validator has a centering mechanism with a self adjustable bill hath The width of the path is automatically adjusted to accommodate each bill The MSM is used for currencies where the width of the bill changes with the denomination The highest acceptance rate is available due to a set of advanced sensors and smart software that can precisely separate authentic bills from all known counterfeits gt VE Six multi colour optical sensors collect images lt a J le Bill validator from both sides of the bill Patented inductive sensors evaluate magnetic properties of specialized ink at the bill Patented dielectric sensors detect authenticity of bill paper and some special protective features of the bill All sensors have auto calibration and do not require any manual adjustment As a result the validator keeps the same high acceptance level during its lifetime The MSM bill validator can accept bills inserted in any of four directions any side forward face up or face down An additional sensor allows reading of bar coded coupons widely used in gaming applications The highest security level is provided by an anti stringing sensor that can detect any sort of string thread or film attached to the bill The highest efficiency is provided in the following features Beltless roller design minimizes maintenance of bill transport mechanism Clamshell design provides fast and easy acce
20. of status light Error description Fault handling flashes 1 Cassette is removed from the bill Check if cassette is installed validator correctly 2 Wrong type of sensors or no Check reliability of electrical communication with sensors connection to processor board transport motor stacking motor check connection PAGE 1 34 Part 1 Operation Manual Rev 03 2004 D CashCod MSM BackLoad Bill Validator Operation and Service Manual Number of Error description Fault handling status light flashes 3 Cassette is full Replace the cassette with empty one 4 Mechanical jam in Cassette or 1 Remove the cassette from the bill stacker motor failure validator and remove jammed bill 2 Turn power on and check stacking motor operation 5 Failure of dielectric sensors Open the guides and clean dielectric sensors 6 Failure of optical sensors Open the guides and clean optical sensors 7 Failure of inductive sensors Open the guides and clean inductive sensors 8 Failure of transport motor 1 Open the guides and clean the bill path 2 Remove the cassette from the bill validator and open the cover Check mechanical and electrical connections 11 Bill pathway is not empty Open the guides and check the condition of the bill path 12 Bill jam in entry slot of the Remove the cassette from the bill cassette No credit issued validator and clean the bill path R
21. ownload process is completed During the download a red green status light will blink Once the download is completed the diagnostic light will turn green Should the light stay red this means there is no communication between the MSM Bill Validator and the host controller A single download Memory stick must be present in the Bill Validator at all times Download procedure for the multi download Smart Stick Please refer to the instructions concerning the single download Memory stick Follow steps 1 2 4 5 and 6 After the successful completion of step 6 follow steps 1 2 3 and 5 The Memory Card can be used to update more units until the number of licenses is reached Download procedure via interface connector In order to properly complete an interface download the Memory stick must be present in the Memory stick slot at all times before and during the download 1 When the SM Bill Validator has a CCNET protocol the software download can be completed via the host controller refer to CCNET Protocol Description 2 For a direct download via the interface connector please follow the instructions below Step 1 Turn power OFF Step 2 Disconnect the interface connector from the Bill Validator Step 3 Connect the CashCode Adaptor For CPU Board 0401017 use adaptor OPT PS2 VU CCNET for Processor Board adapter 0401018 OPT AD MDB PC a to the Computer b to the interface connector of the Bill Validator and c to the pow
22. ss to all portions of the bill path PAGE 1 4 Part 1 Operation Manual Rev 03 2004 D CashCod MSM BackLoad Bill Validator Operation and Service Manual When new bills are issued in circulation or when new counterfeits are found the MSM bill validator has a possibility of a fast and easy software update with the CashCode Memory stick The update can be performed in seconds in the location where the validator is installed The procedure does not require high qualified personnel validator disconnection or any tool or equipment The MSM bill validator operates at a twice faster speed than the previous ST S Interface connectors NS right side SS ee Se 7 Place for customer s sticker lt gt Place for customer s sticker e Bill entrance_ The MSM bill validator has all the required features that allow it to be used in any application It can be installed in the STACKER UP or the STACKER DOWN position It means that the cassette is located above the bill entrance which is more common for vending equipment or below the bill entrance which often used in amusement machines The MSM fits into the most common cutout dimensions at the front door The MSM supports wide variety of interfaces MDB CC serial CCNET IDO03 Typically all connectors are situated at one side of the validator right side In case when the space in the machine at this side is limited the customer may order the MS
23. ssette removal and installation 1 To install the cassette into the bill validator direct two bosses of the cassette to corresponding slots in the validator housing 2 Rotate the cassette in the direction of arrow till fasteners of the cassette hook the latches at the validator housing This action can be done for all types of cassettes whether they are equipped with second metal lock or not as well as for the gaming cassette EN PAGE 1 28 Part 1 Operation Manual Rev 03 2004 eh CashCod MSM BackLoad Bill Validator Operation and Service Manual 3 To remove the cassette squeeze the two fasteners at the rear side of the cassette and pull the cassette If the cassette carries additional locks unlock them first 4 To collect bills from the cassette open the lock or locks at the cassette cover and open the cover Remove bills Close the cover A tee ya no lock variant positions of plastic handle unlocked position locked position Rev 03 2004 Part 1 Operation Manual PAGE 1 29 D CashCod MSM BackLoad Bill Validator Operation and Service Manual Access to the bill path The access to the bill path is possible when the cassette is removed Push the Open the button guides The guides can be closed in any sequence
24. t connected zeeneneee renee YA Not connected Seenen 8 Not connected Seenen 9 Not connected renee 10 Out of Service Any failure Low 11 TXD TTL Transmitted data TTL level High Low 12 Accept Enable Enable accept bill input Low 13 LED Power Source 200 ohm to 5 VDC output High Control system signal initiatin Ge Send transfer a Sistas oceans input 9 Low 15 RXD RS232 Received Data RS232 level High Low 16 RXD TTL Received Data TTL level High Low 17 TXD RS232 Transmitted data RS232 level High Low 18 Not connected IT leen PAGE 1 24 Part 1 Operation Manual Rev 03 2004 QD CashCod MSM BackLoad Bill Validator Operation and Service Manual Input Output circuits For CPU board 0401018 with MDB interface 34V DC P4V AC ADDITIONAL OUTPUT ADDITIONAL INPUT MASTER TRANSMIT MBRS110073 DC AC POWER RE MASTER RECEIVE GROUND MMBT440IL TI BASISLTI BASIGLT1 VD3 MC74HC144D MMBT4401L 71 MC74HCI4AD DDIC al is MC74HCI4AD lt OLLER DLLER FROM MICROCONTR TO MICROCONTR Rev 03 2004 Part 1 Operation Manual PAGE 1 25 D CashCod MSM BackLoad Bill Validator Operation and Service Manual For CPU board 0401017 with CCS IPI CCNET BDS interfaces OUT OF SERVISE ACCEPT ENABLE LED POWER SOURCE INHIBIT LINE
25. te cover can be equipped with the tab for applying a seal PAGE 1 6 Part 1 Operation Manual Rev 03 2004 D CashCod MSM BackLoad Bill Validator Operation and Service Manual Acceptance Eege ee a EE lengthwise 4 ways Barcoded COUPONS items two ways face up for stacker down installation Validating WML sss sre ebe dee SEENEN eee 96 or higher on first insertion Width of bills IM EE 62 77 Maximum length of bill IN ns es mimi han nine 160 Minimum length of bill MMM sienne smart satin idetebeen 120 BH SS CROW RS Kaa io dr cc one bill Barcoded Coupon Specifications Encoding standard SNSI AIM BC2 1995 Uniform Symbology Specification Interleaved 2 of 5 Narrow bar ttc fi Bn EE 0 5 to 0 6 Wide Narrow Bar E EE 3 1 Number Of Charambe 6 to 18 PGS Value Print Contrast Signal ssssssssenemeeniameespslieannnemeterveee 0 6 min Complete transport cycle in seconds 1 7 External Interface Single Price with adapter Host Intelligence Interface HII with adapter UW ii ad de a die ni MDB Pulse opto isolated IPI CCS serial TTL CCNET single slave mode RS232 ID 003 TTL Maximum stacking capacity of new bills in Cassette 300 550 Memory programming download from CashCode Memory Stick or from
26. ver can be used without locks plastic lock gives free access to bills Plastic lock The Cassette can also carry metal lock at its cover providing the next level of security Every cassette can be equipped with the lock that locks the cassette to the bill validator This optional locking mechanism is placed at the rear side of the cassette and prevents the removal of the cassette from the bill validator The locking mechanism can be ordered separately under part number OPT MKLC USX CC1 with the lock installed Rev 03 2004 Part 1 Operation Manual PAGE 1 15 D CashCod MSM BackLoad Bill Validator Operation and Service Manual Every cassette except gaming can have additional tab to apply a seal on the locked cover PAGE 1 16 Part 1 Operation Manual Rev 03 2004 eh CashCod MSM BackLoad Bill Validator Operation and Service Manual Memory Stick and software update options CashCode MSM Bill Validators are supplied with pre installed software according to user s order A Dummy Card is normally placed in the slot instead of a Memory stick Software updates are recommended whenever new currency is issued or whenever a new series of counterfeit bills appear on the market Software updates are offered in three options 1 New software can be ordered with a single download Memory stick The software from the new Memory stick is downloaded as soon as it is inserted into the slot and