Home

Service Manual

image

Contents

1. IMPORTANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment Model 1 Serial Service Manual Solstice 112 Cooking Computer Covering Single Vat P N 60126801 and Dual Vat P N 60126802 ENGLISH OPI o L 1 e 4 i 6 ig 8 9 4 This manual details the operation and adjustment of the Solstice 112 Cooking Computer control developed for Pitco fryer products This microprocessor control offers the latest cooking technology including temperature and time compensation that requires no user adjustments for consistently cooked product Other features include drain valve interlock faulty probe detection selectable melt cycles beeper volume and cook temperature Each product key may be programmed with cook shake and hold times to keep pace with changing menus over time This manual reveals all adjustments that are possible by keyboard entry including passwords The target audience for this manual is the Service Technician L22 278 Rev 1 06 11 Solstice 112 Cooking Computer Service Single Vat 60126801 and Dual Vat 60126802 Table of Contents 1 Key Locations and Functions 5 ocaeca tamea ao raa kara tuu toad aka auda 3 1 1 To turn the appliance ON oo iai Etre hanes ERUpa MER Era Ro meb BS Un ES RE beaus ERUER DE ERR RES 4
2. Turn controller off and refill the vat Continue with normal operations at section 1 HEAT FAILURE OR IGNITION FAILURE This message indicates that the heating system failed to respond Typically the high temperature limit switch has tripped and is in need of resetting In the case on gas fired appliances this message will display if the pilot fails to light or is detected marginal by the ignition module SYSTEM FAILURE This message indicates a shorted probe If probe is detected as a short circuit normal heating and cooking activities are suspended 16 L22 278 Rev 1 06 11 7 Mechanical Dimensions Solstice 112 Cooking Computer Service Single Vat 60126801 and Dual Vat 60126802 En ch dc ch LJ oO Prrco O P bl OA WM i A L 1 2 3 4 5 L t 6 7 8 9 0 R Fog S a Ht Hr c I zl HANTOM KE dus ETE ur E i M Tei oy M 8 i j S i p a fi an 9 EAR VIE Q pu Lo GO m l Popi SI LE LAd 22 278 Rev 1 06 11 Solstice 112 Cooking Computer Service 2 683 Single Vat 60126801 and Dual Vat 60126802 8 Ele
3. Heat will maintain vat temperature at 185 F 85 C for cleaning as long as the control remains on To exit boil mode control must be turned off Warning Pressing any other key at the PRESS 0 TO BOIL prompt is regarded by the control as a NO response With this response the control will apply heat to the vat as if oil were present in the vat With water in the vat a rolling boil will result This will cause undesirable foam over conditions and steam burn hazards to operators performing cleaning operations L22 278 Rev 1 06 11 5 Solstice 112 Cooking Computer Service 2 683 Single Vat 60126801 and Dual Vat 60126802 1 7 2 Manual Boil Entry After filling an empty vat with water turn the appliance on Press the thermometer key and enter key sequence 2 1 2 f control is set Manual Boil Out Entry to display in the Celsius scale press 1 0 O keys to manually vs enter boil mode The display will show BOIL to indicate entry into LB a a boil mode To exit boil mode control must be turned off Enter 100 for Celcius Displays 1 10 0 2 To Enter Programming Level 1 for the Store Manager Note The factory default setting for this control does not require an operator password to be entered However the operator password requirement and value may be changed in section 3 2 This text assumes the operator pas
4. 4 8 8 Factory Reset Factory Reset provides a quick way to erase all setup changes and restore control to factory settings Warning Any settings made prior to a factory reset will be lost This includes customer specific downloads performed at Pitco Frialator With display showing MORE SERVICE press 8 product key After a few moments the display will show P Press the P display will return to MORE SERVICE 4 8 9 Standing Pilot Toggle For some applications it is desirable to maintain the gas pilot flame when the appliance is OFF Heat from the pilot keeps solid shortening in the liquid state for quicker warm ups in the morning Default setting for standing pilot is off Note Heat Demand Profile section 4 8 3 must be set to Generic 1 or T stat Standing Pilot toggle has no effect in with any other setting With display showing MORE SERVICE press product key 9 Display will show STANDING PILOT n where n is ON or OFF Use product key 0 change value then press the P to save choice Display returns to MORE SERVICE L22 278 Rev 1 06 11 13 Solstice 112 Cooking Computer Service 2 683 Single Vat 60126801 and Dual Vat 60126802 4 8 10 To Exit More Service Menu With display showing MORE SERVICE press the P key Display returns to SERVICE Continue with Level 2 programming in section 4 display showing SERVICE or continue 4 9 To Exit Programming Level 3 e With display showing
5. 42 To turn the appliance OFF ieseet eto titt a arta aad rh maa Elke ta emen dann 4 E GER A 1 4 Toca cel a ET 4 1 5 To check Actual and Set temperatures cee ceeeceeseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeteeneeees 4 1 6 To View Current Settings for cook shake and hold times 5 1 7 To perform a Boll Out operatlon oe c eer En rb Rt n ES eu Ru E POUR P PE EE RES 5 1 7 1 Automatic Boil Entry Water Detection sssssseseeeeneeneens 5 1 7 2 Manual Boil Emtee 6 2 To Enter Programming Level 1 for the Store Manager 6 2 1 To Set Cook Temperature oee entrar ud edes Po UE ER LA RAS EREXREA FERREA FR EEN FREDU NEE 6 2 2 To Change a Product Key Cook Shake Hold and Hold Pre Alarm Times 6 2 2 1 OOK TG 6 222 Shake ME 7 2 2 3 Elie Wi 7 2 2 4 Hold PresAIArm nectit trenta kani post ara aa AEE N AAE A EN 7 2 3 To Exit Level 1 programming m cm 7 3 To Enter Programming Level 2 for the Store Manager 7 3 1 Fahrenheit or Celsius Eeleren ieggsdegsegeere eu Seege Eege tact dee eise 8 3 2 Password Change or Required vicscccisccsicicsesscorttesavaanertuessivecs Ron por eo E en EE SUE Deng 8 3 3 Beeper Volume and TONG tr ret nnda rhe Ehre terms xcii rio pH 8 CU MEME e e EE 8 3 5 Melt Cycle Type ee eege ege 9 SE Io CAELI rr M 9 3 7
6. Clock key Display will show SELECT PRODUCT Press the desired product key to change AUN The display is now showing nCK mm ss TIME where n is the key number CK means Cook and mm ss is minutes and seconds Use the product keys for numeric entry to adjust the current setting Press the Clock key to save cook time and continue setup for this product key CA 6 22 278 Rev 1 06 11 Solstice 112 Cooking Computer Service Single Vat 60126801 and Dual Vat 60126802 2 2 2 Shake Time Shake time is an alarm that sounds during Cook Time to prompt operators to shake the basket Default for this value is zero meaning the Shake Time is inactive To use Shake Time time value must be a non zero value and must be set to a value less than cook time Display shows nSH mm ss TIME where n is the key number SH means Shake and mm ss is time in minutes and seconds CH w Use the product keys for numeric entry to adjust the current setting Press the Clock key to save shake time and continue setup for this product key Note Cook Time minus DisplayShake Time Shake Value Entry Example 3 00 cook time with a 2 00 shake time the value you enter would be 1 00 minute 2 2 3 Hold Time Cooked product may stand in holding bins for a period of time This timer produces an alarm to inform operators to discard old product and start a new cook Default for this value
7. 6 Lamp Test Press the product key 6 All display indicators will be forced on The purpose is to reveal non functional indicators or displays 4 5 7 Heat Feedback Input Press the product key 7 Display will show state of the Heat Feedback input FB xxx where xxx is ON or OFF Product key 7 indicator shows the ON or OFF state of the input 4 5 8 Left or Right Side Select Dual Vat only Press the product key 0 Display will show DIAG LEFT Press key 0 again to select the right side for diagnostic keys in this section 4 5 9 Exit Diagnostic Menu To exit diagnostic menu Press the P key Display will return to SERVICE Other service menu items may be selected for changes L22 278 Rev 1 06 11 11 Solstice 112 Cooking Computer Service 2 683 Single Vat 60126801 and Dual Vat 60126802 4 6 Ready Level With display showing SERVICE press product key 6 Display shows READY nn where nn is the value in degrees below set temperature that the READY message is displayed To change this value use the product keys for To return to programming press the P key again Display will show D PROGRAM Other settings can be made in section 2 gt To return to normal operations press the P key again Display will show one of the normal displays HEATING MELT LIQUID or SOLID or READY numeric entry of a new value Press the P key Display now shows SERVIC
8. 9812 350 1767 942 00 25 3 9 360589 190 87 8 8995 355 179 4 889 67 30 1 1 312474 195 90 6 8255 360 182 2 840 78 35 1 7 271446 200 93 3 7586 365 185 0 795 10 40 4 4 236370 205 96 1 6979 370 187 8 752 38 45 7 2 206311 210 98 9 6427 375 190 6 712 41 50 10 0 180491 215 101 7 5926 380 193 3 674 95 55 12 8 158252 220 104 4 5470 385 196 1 639 87 60 15 6 139055 225 107 2 5055 390 198 9 606 96 65 18 3 122489 230 110 0 4675 395 201 7 576 09 70 21 1 108051 235 112 8 4329 400 204 4 547 09 75 23 9 95539 240 115 6 4013 405 207 2 519 86 80 26 7 84644 245 118 3 3723 410 210 0 494 24 85 29 4 75136 250 121 1 3458 415 212 8 470 16 90 32 2 66823 255 123 9 3214 420 215 6 447 49 95 35 0 59540 260 126 7 2991 425 218 3 426 13 100 37 8 53146 265 129 4 2785 430 221 1 406 02 105 40 6 47523 270 132 2 2597 435 223 9 387 04 110 43 3 42569 275 135 0 2422 440 226 7 369 14 115 46 1 38195 280 137 8 2262 445 229 4 352 24 120 48 9 34328 285 140 6 2113 9 450 232 2 336 29 125 51 7 30902 290 143 3 1977 3 455 235 0 321 21 130 54 4 27862 295 146 1 1851 0 460 237 8 306 94 135 57 2 25161 300 148 9 1734 3 465 240 6 293 46 140 60 0 22755 305 151 7 1626 1 470 243 3 280 69 145 62 8 20610 310 154 4 1525 9 475 246 1 268 61 150 65 6 18695 315 157 2 1433 0 480 248 9 257 15 155 68 3 16981 320 160 0 1346 7 485 251 7 246 30 160 71 1 15446 325 162 8 1266 6 490 254 4 236 00 165 73 9 14069 330 165 6 1192 1 495 257 2 226 24 170 76 7 12823 335 168 3 1122 8 500 260 0 216 96 Notes Resistance of
9. Control or Timer Left side of Dual or Single Va 9 3 8 Control or Timer Right side of Dual Va 9 4 To Enter Programming Level 3 for the Technician 10 4 1 Offset Temperature Display 10 4 2 Melt Cycle ON ME m 10 4 3 Min Gyele TIME eenaa a a ea EA E 10 4 4 Recovery THING sect ctdancnsiech ncaa ssatevesaindeabsndes toancbannes cteassidared oacepnnaneigunsdenstecarsiecscs 10 4 5 Diagnostic Menu Entry ccc midis ene cca tities eae 11 4 5 1 Left Basket Lift Output 11 4 5 2 Right Basket Lift Oufmput eene nennen enne nnns 11 4 5 3 Heat Demand Output seii ea rd noe ENEE CHE Sena dna SEENEN 11 4 5 4 Side alle lr EE 11 45 5 Drain Switch Input ad Gittins endl dire CERS 11 45 0 Lamp Test eed ade ar eie eoe eoe wid ERR SCR ne Cre edna 11 4 5 7 Heat Feedback InpUt ue eret iere bedenken dee 11 L22 278 Rev 1 06 11 Solstice 112 Cooking Computer Service Single Vat 60126801 and Dual Vat 60126802 4 5 8 Left or Right Side Select Dual Vat oni 11 4 5 9 Exit Diagnostic Men 11 46 Ready E 12 4 7 Temperature Operating Range scccsicscsctacdecntdeartseencavivciortaesastianiatiGaneion don eiadsas 12 4 8 Mor Service Menu Entry etre n ER EUER REN RXI NERA eee 12 4 8 1 GOOK NOW 12 4 8 2 Turbo Select Single Onhy nennen 12 4 8 8 Heat Demand Profile 12 4 8 A Shake Alarm Duration 13 4 85 Hold Alarm Duratton ener entretenir sen nennen 13 48 6 Can
10. SERVICE press the P key Display will show PROGRAM Continue with changes in section 2 or continue D e To return to normal operations press the P key again Display will show one of the normal displays HEATING MELT LIQUID or SOLID or READY 5 Factory Menu Level 4 for the Technician With no cook timers running displays will show one of the following displays D HEATING MELT LIQUID or SOLID or READY Press the P program key Left display will show PROGRAM Right display will be blank Factory Password Enter password 1993 using the product keys as numeric keypad for entry SHEE Display will show FACTORY Product key indicators will illuminate to prompt operator to select a key This section details parameters that may be changed in Factory programming rm LESS 5 1 Offset Temperature Display This adjustment allows the displayed temperature value to be offset to reflect the true center vat temperature while reading the probe tip temperature Default value is zero With zero value set displayed values are the probe temperature With display showing FACTORY press product key 1 Display shows OFF nn F DEGREES where nn is the value of the adjustment Negative values are preceded with a minus sign To change this value use the product keys for numeric entry of a ne
11. be acknowledged All other product indicators are off With a set value of OFF no other cooks can start until product key 2 is pressed to acknowledge and clear the cook done alarm With a value of ON set a cook on the right side of the control keys 6 H may be started before operator clears the cook done alarm for product key 2 on the left side 4 8 2 Turbo Select Single Only With display showing MORE SERVICE press product key 2 Display will show TRBO OFF TURBO This setting is for use on Pitco s Turbo Fry appliance It should remain OFF for all other applications Use product key 0 change value then press the P to save choice Display returns to MORE SERVICE 4 8 3 Heat Demand Profile With display showing MORE SERVICE press product key 3 Display will show xxxxxxx HEAT DEM where xxxxxxx may be one of 5 heat control profiles listed below 1 GENERIC 1 for gas fired fryer appliance This is the factory default L22 278 Rev 1 06 11 Solstice 112 Cooking Computer Service Single Vat 60126801 and Dual Vat 60126802 GENERIC 2 for electric fryer appliances and model SGH50 T STAT control operates as a mechanical thermostat for general purpose applications on gas or electric fryers This setting offers the quickest possible recovery times at the expense of temperature overshoot suppression 4 HE RPB for use with High Efficiency RPB models only 5 HE ADV for use with High Efficiency Adva
12. displays D HEATING MELT LIQUID or SOLID or READY Press the P program key Left display will show PROGRAM Right display will be blank HAE Enter password 6685 using the product keys as numeric keypad for entry Display will show SERVICE Product key indicators will illuminate to ea E prompt operator to select a key This section details parameters that GJE Mr ILE may be changed in Level 2 programming 4 1 Offset Temperature Display This adjustment allows the displayed temperature value to be offset to reflect the true center vat temperature while reading the probe tip temperature Default value is zero With zero value set displayed values are the probe temperature With display showing SERVICE press product key 1 Display shows OFF nn F DEGREES where nn is the value of the adjustment Negative values are preceded with a minus sign To change this value use the product keys for numeric entry of a new value Press the P key Display will show POSITIVE DEGREES Use the product key 0 to scroll choices Positive or Negative value After selection press the P key Display shows SERVICE Note Computer Display Temp Center Oil Temp Offset Example Computer Display shows 350F while Center Oil Temp measures at 352F 350F 352F 2F neg
13. either probe lead to the frame of the appliance should read as open on the meter Typically this is 1Meg ohms or more L22 278 Rev 1 06 11 19 In the event of problems with or questions about your order please contact the Pitco Frialator factory at 603 225 6684 World Wide www pitco com In the event of problems with or questions about your equipment please contact the Pitco Frialator Authorized Service and Parts representative ASAP covering your area or contact Pitco at the numbers listed to the left MAILING ADDRESS P O BOX 501 CONCORD NH 03302 0501 SHIPPING ADDRESS 10 FERRY ST CONCORD NH 03301 L22 278 Rev 1 06 11
14. is zero meaning the Hold Time is inactive Display is showing nHD mm ss TIME where n is the key number HD means HOLD and mm ss is minutes and seconds Use the product keys for numeric entry to adjust the current setting Press the Clock key to save hold time and continue setup for this product key 2 2 4 Hold Pre Alarm Hold Pre Alarm is a timer setting that is used to warn operators that the Hold Time is about to expire To use Hold Pre Alarm time value must be a non zero value and must be set to a value less than Hold Time Default value is zero meaning the Hold Pre Alarm is inactive Display is showing NPA mm ss TIME where n is the key number PA means Pre Alarm and mm ss is minutes and seconds Use the product keys for numeric entry to adjust the current setting Press the Clock key to save cook time and continue setup for this product key Note Value entered for Hold pre alarm time is the hold time minus the pre alarm time Example 15 00 hold time with a 5 00 prealarm time the value you enter would be 10 00 minutes Display will again return to SELECT TIME Repeat steps from section 2 3 1 to make changes to any other product keys or continue 2 3 To Exit Level 1 programming Display shows SELECT TIME Press the P key Display shows PROGRAM Continue to section 3 to change options or exit here in the next step To exit Level 1 progr
15. E 4 7 Temperature Operating Range Forces the control to display the range on temperatures that may be set by operators 7 With display showing SERVICE press product key 7 Display shows RANGE 1 200 380 No adjustments are permitted here This is an information display only Press the P key Display returns to SERVICE 4 8 More Service Menu Entry With display showing SERVICE press product key 8 Display now shows MORE 8 SERVICE Product keys will illuminate where adjustments are permitted all other keys are inactive The following section details each product key function in the More Service Menu 12 4 8 1 Cook Now Should operators be forced to acknowledge a Cook Done Alarm before starting another cook This setting forces that requirement Factory default value is OFF With display showing MORE SERVICE press product key 1 Display will show NOW xxx COOK NOW where xxx is ON or OFF Use product key 0 change value then press the P to save choice Display returns to MORE SERVICE Note With OFF value selection operators must acknowledge a done cook DONE n display before starting any another cooks With an ON value operators are permitted to start a cook on the opposite side before acknowledging a cook done alarm Example The left display is showing DONE 2 with the beeper alarm sounding Indicator 2 is flashing needing to
16. age Selection With display showing PROGRAM press the product key 0 Display shows SELECT OPTIONS Press product key 4 display shows ENGLISH LANGUAGE A Use the product key 0 to scroll through choices ENGLISH ESPANOL FRANCAIS HM DEUTSCH HOLLAND Press P key to save choice Display shows PROGRAM 8 L22 278 Rev 1 06 11 Solstice 112 Cooking Computer Service Single Vat 60126801 and Dual Vat 60126802 3 5 Melt Cycle Type This adjustment allows selection of the melt cycle type or disabling the melt cycle requirement when starting the appliance from a cold start With display showing PROGRAM press the product key 0 Display will show SELECT OPTIONS Press product key 5 display shows LIQUID the default setting H Use the product key 0 to scroll through choices liquid solid no melt Press P key to save choice Display will again return to PROGRAM 3 6 X Recovery Test Value This controller maintains a record of heat up times for the appliance A poorly running appliance will have increased recovery times stored in this display There is no selection done here just the display of recovery time values With display showing PROGRAM press the product key 0 E Display shows SELECT OPTIONS Press product key 6 display will show RECOVERY TEST Press the product key 0 Display will show FnnnLyyy where nnn is the fa
17. amming press the P key again Displays will show HEATING MELT LIQUID or SOLID or READY 3 ToEnter Programming Level 2 for the Store Manager The display must show PROGRAM from section 2 to change these options When the product key 0 is pressed the display will show SELECT OPTIONS Indicator lights above product keys will illuminate to represent options that may be changed Each option listed below uses the product key 0 to toggle or scroll through available choices L22 278 Rev 1 06 11 Solstice 112 Cooking Computer Service 2 683 Single Vat 60126801 and Dual Vat 60126802 in the display When the correct value is displayed press the P key to save choice The display will again return to PROGRAM for another option selection 3 4 Fahrenheit or Celsius Display The Controller will display temperatures in the Fahrenheit or Celsius scales The default scale is F With display showing PROGRAM press the product key 0 Display shows SELECT OPTIONS 1 Press product key 1 display shows DEGREE n F OR C where n is the current setting Use the product key 0 to scroll through choices F or C Press P key to save choice Display shows PROGRAM 3 2 Password Change or Required With factory settings an operator password is not required to enter programming Levels 1 and 2 The password may be activated or changed in this sec
18. cel Durali e serr tito tetro RERNA ENNEN RAKEAN EAREN ERARA RAKAR ANEN 13 4 8 7 Configuration Value sss enne nnne nnn nnns inten en nnns sn nn nsn 13 4 8 8 gene LET 13 4 8 9 Standing Pilot Toggle un 13 4 8 10 To Exit More Service Menu ccccccceccescecesseceeeeseeeeeecsneeeesseesseeesseesaeessensaeenseenaees 14 4 9 To Exit Programming EE D 14 5 Factory Menu Level 4 for the Technician sees 14 5 1 Offset Temperature Display AEN 14 5 2 Melt Cycle On Time uscecessecte Go irren geed Eeer hinges 14 53 Minimum Cycle in 14 5 4 Recovery Run 15 5 5 Diagnostic Menu DEE EE 15 5 6 0 0 qE u EN 15 5 7 Operating Temperature Range nn 15 5 8 e e Limit 7er 15 5 9 Basket Lift dual control Only uuo pies iata vage Se ta REEF eer Ro ege EE 15 xm ree e ay 15 541 To Exit Factory Menu Level denges eege eege ed ee rrr ee Uie cernat 15 6 Other RUE 16 7 Mechanical DImenslOnS cen eres treno Fen ek en paa eon Feo EY PR EY ay ER R3 Y aa EX PR Yay C Ras Res ege 17 8 Electrical Connections at J1 eeeeeeeeeeeeeeeseeeeeeeeeeeennnn 18 9 Electrical Connections at J2 Dual Vat Only 18 10 Probe Resistance ier Pe 19 1 Key Locations and Functions L22 278 Rev 1 06 11 3 Solstice 112 Cooking Computer Service 2 683 Single Vat 60126801 and Dual Vat 60126802 12 Product 12 Product On Off Program Thermometer Clock On Off Keys Key I
19. ctory recovery value and yyy is the last warm up recovery value After recording these values press the P key Display returns to PROGRAM 3 7 Control or Timer Left side of Dual or Single Vat With display showing PROGRAM press the product key 0 Display shows SELECT OPTIONS Press product key 7 display will show CONTROL Use the product key 0 to scroll through choices Control Timer Press P key to save choice Display shows PROGRAM Note If timer is selected heat control outputs are disabled leaving only the timer functions active Do not make this selection on Solstice fryer models 3 8 Control or Timer Right side of Dual Vat Note This key has no function of single vat controls With display showing PROGRAM press the product key 0 Display shows SELECT OPTIONS Press product key 8 display will show CONTROL Use the product key 0 to scroll through choices Control Timer Press P key to save choice Display shows PROGRAM Note If timer is selected heat control outputs are disabled leaving only the timer functions active Do not make this selection on Solstice fryer models L22 278 Rev 1 06 11 9 Solstice 112 Cooking Computer Service 2 683 Single Vat 60126801 and Dual Vat 60126802 4 ToEnter Programming Level 3 for the Technician With no cook timers running displays will show one of the following
20. ctrical Connections at J1 91 inputs Type Nomina Note 2AVAC 2AVAC 20 15 50 60Hz 24VACN__ 24VAC Return Proble eut 6 IER N DOG HeatFeedBack 8 D OUT avDC HeatDemand 9 soren our VDC SideONorXFER r3 Case 5 ANZ 99 Tip Use the diagnostic menu to check outputs and verify d b inputs H H J1 AO OOS QOG UE 9 Electrical Connections at J2 Dual Vat Onl 31 Inputs Type Nominal Notes PRE varies with vat temperature 942 ER PROBE Proble 9 350 F 5 DVI IN 24VAC Drain Valve Interlock 6 j HFB IW a4VAC Heat Feed Back 8 HD OUT 4VDC eat Demand 9 SOXFER OUT 24VDC SideONorXFER 18 L22 278 Rev 1 06 11 Solstice 112 Cooking Computer Service Single Vat 60126801 and Dual Vat 60126802 10 Probe Resistance Chart Probe Resistance in 5 F Increments Probe Probe Probe Probe Probe Probe Temp Temp Resistance Temp Temp Resistance Temp Temp Resistance F C Ohms F C Ohms F C Ohms 10 12 2 562734 175 79 4 11719 340 171 1 1058 23 15 9 4 483875 180 82 2 10716 345 173 9 998 09 20 6 7 417167 185 85 0
21. lowed by the desired product key The display will show CKn mm ss followed by SHn mm ss then HDn mm ss Where n is the key number and mm ss are the current settings for time After a few moments the display will return to READY MELT or HEATING or CKn mm ss for a cook still running Typical displays using key 4 as an example Key 4 set for 3 minutes and 28 seconds cook time Key 4 Shake Time is set for 2 minutes and 00 seconds before L L4 L4 the end of the Cook EN Key 4 Hold Time in set for 10 00 minutes II i 1 RN In a few moments the display will return to READY 1 7 To perform a Boil Out operation Normal maintenance of a fryer requires regular tank cleaning This process involves draining the vat of oil and filling with water Cleaning solution is added and the control is set to the boil out mode by one of the following methods 1 7 1 Automatic Boil Entry Water Detection After filling an empty vat with water turn the appliance On Heat will be applied to the vat warming the water This control will detect the presence of water by temperatures not rising above the boiling point of water 212 F 100 C After a time at this temperature displays will show Heat will be disabled until the operator responds to this prompt Pressing the 0 key is a YES response to the boil prompt If pressed display will show
22. mperatures displayed by the controller are probe tip temperatures unaltered by values set in section 4 1 or 5 1 For normal operations this setting should remain OFF To change this value use product key 0 to toggle choice ON or OFF Press the P key Display now shows FACTORY 5 11 To Exit Factory Menu Level 4 To exit Factory Programming Press the P key D Display will show PROGRAM Continue with settings in section 2 or continue To return to normal operations press the P key again Display will show one of the normal displays HEATING MELT LIQUID or SOLID or D READY ZS L22 278 Rev 1 06 11 15 Solstice 112 Cooking Computer Service 2 683 Single Vat 60126801 and Dual Vat 60126802 6 Other Displays PROBE OP OPEN Open probe detection is standard on all Pitco controls If probe is detected open normal heating and cooking activities are suspended HIGH TMP HIGH TMP This display warns operators that the vat temperature has exceeded set temperature by 40 F 22 C or an absolute maximum of 410 F 210 C This display does not show the status of the mechanical high limit switch DRAINING TURN OFF This message indicates that the drain valve has been opened the vat is assumed to be empty by the controller Normal heat control activities are suspended To restore to normal operation close the drain value Display will show TURN OFF TURN OFF
23. nce models only Use product key 0 change value then press the P to save choice Display returns to MORE SERVICE 4 8 4 Shake Alarm Duration With display showing MORE SERVICE press product key 4 Display will show SH DUR nn DURATION where nn is the time in seconds the shake alarm will sound Use product keys for numeric entry of desired value then press the P to save choice Display returns to MORE SERVICE 4 8 5 Hold Alarm Duration With display showing MORE SERVICE press product key 5 Display will show HD DUR nn DURATION where nn is the time in seconds the hold alarm will sound Use product keys for numeric entry of desired value then press the P to save choice Display returns to MORE SERVICE 4 8 6 Cancel Duration With display showing MORE SERVICE press product key 6 Display will show CANCEL nn DELAY where nn is the time in seconds the operators must press a basket key to cancel a cook Use product keys for numeric entry of desired value then press the P to save choice Display returns to MORE SERVICE Default value is 2 seconds 4 8 7 Configuration Value With display showing MORE SERVICE press product key 7 Display will show CFG hhhh where hhhh is a hexadecimal check sum of the program contained in the controller Modifications to any part of the setup of this control will change the check sum value Press the P display will return to MORE SERVICE
24. ndicators Key Key Key Key Key Doron g CITA f dun OICHT Heat Demand CEO mu Indicators Displays show current operation Throughout this text a left only display will be printed as CK4 2 28 When both left and right displays should be interpreted together this text will show them as CK4 2 28 READY 1 1 Toturn the appliance ON If power is applied to the appliance the displays will show OFF Press the I O key fec Displays will show one of the normal displays HEATING MELTING SOLID LIQUID or READY Some messages may show in both left and right V displays Wait for the appliance to heat up to the READY condition before cooking 1 2 Toturn the appliance OFF Press the I O key Display will momentarily show the software version number and then OFF OFF Use the Left I O key for left side and Right I O key for the right of dual vat control 60126802 Either key may be used on the single vat controller 1 3 Tostart a cook When displays are showing READY the appliance has reached set temperature and is ready to cook Press the desired product key and place product into the vat The indicator above the product key will flash to indicate the cook timer is running In the example above product 4 is cooking with 2 mi
25. nutes and 28 seconds remaining The right side display has no running cook timers and shows READY Multiple cooks may run together While cooks are running the displays will always show the cook with the least time remaining Longer running cooks will flash their indicators at a slower rate Cook time remaining on these keys may be checked by momentarily pressing the product key 1 4 To cancel a cook Press and hold the product key to cancel a running cook If no other cooks are pending controller displays will return to READY 1 5 To check Actual and Set temperatures To view the actual vat temperature press the thermometer key The display will show ACT nnnF or ACT nnnC where nnn is the current vat temperature After a few moments the display will return to READY MELT or HEATING when no cooks are running or CKn mm ss for any cooks still running 4 L22 278 Rev 1 06 11 Solstice 112 Cooking Computer Service Single Vat 60126801 and Dual Vat 60126802 To view the set temperature press the thermometer key twice The display will show SET nnnF or SET nnnC where nnn is the current set temperature UM After a few moments the display will return to READY MELT or ua HEATING or CKn mm ss for a cook still running 1 06 To View Current Settings for cook shake and hold times f rs To view the current settings for any product key press the clock key fol
26. oblem is controller related In the diagnostic menu product keys are assigned specific inputs or outputs All outputs in the ON state should produce 24VDC at the appropriate pins on the controller connector Controller inputs can be verified by the on or off state of the indicator above the product key This section details the process of checking each input and output With display showing SERVICE press product key 5 H Display will show DIAGNOST DIAGNOST Note For dual vat controls use key 0 sect 4 5 8 to select left of right side for the following diagnostics Key 0 has no function of single vat controls 4 5 1 Left Basket Lift Output Press the product key 1 to toggle the left basket lift output ON Display will show L BASKET Press again to toggle output OFF 4 5 2 Right Basket Lift Output Press the product key 2 to toggle the right basket lift output ON Display will show R BASKET Press again to toggle output OFF 4 5 3 Heat Demand Output Press and hold the product key 3 to force Heat Demand output ON Display will show HEAT DEM Releasing the key will force output OFF 4 5 4 Side On Output Press the product key 4 to toggle the Side ON output ON Display will show SIDE ON Press again to toggle output OFF 4 5 5 Drain Switch Input Press the product key 5 Display will show state of the Drain Valve input Display will show DRN ON or OFF Product key 5 indicator shows the ON or OFF state of the input 4 5
27. offset value Warning Proper equipment and expertise is required to properly adjust this value Even small changes may negatively effect cooking performance 4 2 Melt Cycle ON Time With display showing SERVICE press product key 2 Display shows MLTON nn MELT ON where nn is the value in seconds of time for a melt cycle heat pulse To change this value use the product keys for numeric entry of a new value Press the P key Display now shows SERVICE 4 3 Min Cycle Time 3 With display showing SERVICE press product key 3 Display shows MIN ON nn MIN ON where nn is the value in seconds of time for minimum heat pulse period To change this value use the product keys for numeric entry of a new value Press the P key Display now shows SERVICE 4 4 Recovery Time E With display showing SERVICE press product key 4 10 L22 278 Rev 1 06 11 Solstice 112 Cooking Computer Service Single Vat 60126801 and Dual Vat 60126802 Display shows RECY nnn RECOVERY where nnn is the last cold start recovery time No adjustments are permitted here This is an information display only Press the P key Display returns to SERVICE 4 5 Diagnostic Menu Entry The diagnostic menu is used to determine the functionality of controller outputs and inputs By exercising each output and examining inputs a determination can be made if an appliance pr
28. sword is disabled Entry of a password when NOT required will not interfere with the programming process With no cook timers running displays will show one of the following displays HEATING MELT LIQUID or SOLID or READY Press the P program key Left display will show a PROGRAM Right display will be blank D Enter password 6684 using the product keys as numeric keypad for entry Level 1 amp 2 Password IA Display still shows PROGRAM EE From the PROGRAM display continue with this section or go to section 3 E 2 1 ToSet Cook Temperature Press the thermometer key once for Single Vat left side of Dual Vat or press key twice for Dual Vat right side of Dual Vat The display will show SET xxxF TEMP or SET xxxC TEMP where xxx is the temperature setting Use the product keys for numeric entry to adjust the current setting Press the P en key to save setting Display now shows PROGRAM To exit here press P again or D continue 2 2 To Change a Product Key Cook Shake Hold and Hold Pre Alarm Times For each product key Cook Shake Hold and Hold Pre alarm times are set in this section With display showing PROGRAM continue with the following section for each product key to change 2 2 4 Cook Time Cook Time may be set for each product key To deactivate any product key enter a zero value for cook time Press the
29. tart recovery time EE No adjustments are permitted here This is an information display only Press the P key Display returns to FACTORY 5 5 Diagnostic Menu Entry Same as section 4 5 except FACTORY is displayed instead of SERVICE 5 6 Ready Level With display showing FACTORY press product key 6 G Display shows READY nn where nn is the value in degrees below set temperature that the READY message is displayed To change this value use the product keys for numeric entry of a new value Press the P key Display now shows FACTORY 5 7 Operating Temperature Range With display showing FACTORY press product key 7 This forces the control to display the range of temperatures that may be set by operators is Display shows RANGE 1 200 380 No adjustments are permitted here This is an information display only Press the P key Display returns to FACTORY 5 8 High Limit Value Pressing product key 8 forces the control to display the temperature above set temperature the high limit alarm will sound Changes may be made buy using the product keys for numeric entry Press the P key Display now shows FACTORY 5 9 Basket Lift dual control onl Key 9 has no function on single vat fryers 5 10 Test On Off With display showing FACTORY press product key 0 H Display shows TEST xx where xx is ON or OFF If ON is selected te
30. tion With display showing PROGRAM press the product key 0 Display will show SELECT OPTIONS Press product key 2 display shows SET PASS NEW PASS Use the product key 0 to 2 scroll through choices NO PASS or PASS REQ Press P key to save choice If NO PASS is selected Display returns to PROGRAM If PASS REQ is selected display will show PASSnnnn NEW PASS to prompt for new password Displayed value nnnn is the current password Use the product keys for numeric entry to change password Press P key to save choice Display shows PROGRAM Note The factory default password 6684 will always work even if a different password is selected above 3 8 Beeper Volume and Tone Volume and Tone of the beeper alarm may be changed in this section Volume ranges are 1 2 and 3 where 3 is the loudest setting Later model controls have an additional selection for tones With display showing PROGRAM press the product key 0 Display will show SELECT OPTIONS Press product key 3 display shows VOLUME n BEEPER Use the product key 0 to scroll through choices n 1 2 3 or T Beeper B volume will change as each selection is made If T is selected an additional display is shown TONE n BEEPER Use the product key 0 to scroll through choices n 1 2 3 Beeper tone will change as each selection is made Press P key to save choice Display shows PROGRAM 3 4 Langu
31. w value Press the P key Display will show POSITIVE DEGREES Use the product key 0 to scroll choices Positive or Negative value After selection press the P key Display shows FACTORY Note Computer Display Temp Center Oil Temp Offset Example Computer Display shows 350F while Center Oil Temp measures at 352F 350F 352F 2F neg offset value Warning Proper equipment and expertise is required to properly adjust this value Even small changes may negatively effect cooking performance 5 2 Melt Cycle On Time With display showing FACTORY press product key 2 Display shows MLTON nn MELT ON where nn is the value in seconds of time for a melt cycle heat pulse To change this value use the product keys for numeric entry of a new value Press the P key Display now shows FACTORY 5 38 Minimum Cycle Time With display showing FACTORY press product key 3 14 L22 278 Rev 1 06 11 Solstice 112 Cooking Computer Service Single Vat 60126801 and Dual Vat 60126802 Display shows MIN ON nn MIN ON where nn is the value in seconds of time for minimum heat pulse period To change this value use the product keys for numeric entry of a new value Press the P key Display now shows FACTORY 5 4 Recovery Time With display showing FACTORY press product key 4 Display shows RECY nnn RECOVERY where nnn is the last cold s