User Manual PH 9310 15 / 20 / 30
Contents
1. Step 2 UPS input connection Plug the UPS into a two pole three wire grounded receptacle only Avoid using extension cords For 208 220 230 240VAC models The power cord is supplied in the UPS package Note For Low voltage models Check if the site wiring fault indicator lights up in LCD panel It will be illuminated when the UPS is plugged into an improperly wired utility power outlet Refer to Troubleshooting section Step 3 UPS output connection For socket type outputs there two kinds of outputs programmable outlets and general outlets Please connect noncritical devices to the programmable outlets and critical devices to the general outlets During power failure you may extend the backup time to critical devices by setting shorter backup time for non critical devices For terminal type input or outputs on the 3K UPS please follow below steps for the wiring configuration a Remove the small cover of the terminal block b Suggest using AWG14 or 2 1mm2 power cords c Upon completion of the wiring configuration please check whether the wires are securely affixed d Put the small cover back to the rear panel PH 9310 PH 9315 PH 9320 PH 9330 ININTERRUPTA Uninterruptible Power Supply 2 Installation and setup Step 3 Communication connection varies depending on the model Communication port USB Port RS 232 Port Intelligent Slot SJ Ae To allow for unattended UPS shutdown start up and st
2. 2 3 4 Indica o do display LCD 27 3 5 Configura o da UPS 28 3 6 Descri o do modo operativo IS 3 7 C digo de ero IB 3 8 Indicadores de alerta D d Solu o de problemas A3 o Armazenamento e manuten o Ab 6 Especifica es a CG PH 9310 PH 9315 PH 9320 PH 9330 ININTERRUMPIDA Sistema de Alimenta o Ininterrupta Seguridad y armon a 1 Aviso de seguran a importante Siga rigorosamente todos os avisos e instru es deste manual Guarde este livro e leia atentamente as seguintes instru es antes de instalar a unidade N o utilize este aparelho sem ler atentamente todas as informa es e instru es de seguran a 1 1 Transporte Por favor transporte a UPS na caixa original para a proteger contra poss veis choques e pancadas 1 2 Prepara o Quando a UPS passa de um ambiente quente a um ambiente frio pode criar condensa o O equipamento deve estar completamente seco antes da instala o Por favor deixe a UPS pelo menos duas horas em ambiente quente N o instale a UPS perto de gua ou em ambientes h midos N o instale a UPS exposto luz solar directa ou fontes de calor N o cubra as sa das de refrigera o da UPS 1 3 Instala o N o ligue a sa da da UPS aos dispositivos que podem sobrecarregar impressoras a laser por exemplo Coloque os cabos de forma a que n o possa trope ar ou serem pisados N o ligue s tomadas da UPS equipamentos como secad
3. Seguridad y armonia ININTERRUMPIDA 1000 1500 2000 3000 Manual de uso Manual de utiliza o User Manual RACK SAI ONLINE UPS ONLINE ONLINE UPS Sistema de Alimentaci n Ininterrumpida Sistema de Alimenta o Ininterrupta Uninterruptible Power Supply PH 9310 PH 9315 PH 9320 PH 9330 O 2013 PHASAK PHASAI Seguridad y armon a ININTERRUMPIDA o ESPANOL as PORTUGU S INGLES PH 9310 PH 9315 PH 9320 PH 9330 Sistema de Alimentaci n Ininterrumpida ININTERRUMPIDA INDICE ee 1 Aviso importante sobre seguridad 2 1 1 Transporte 2 1 2 Preparaci n 2 1 3 Instalaci n 2 1 4 Funcionamiento 2 1 5 Mantenimiento y reparaci n 2 2 Instalaci n y configuraci n 3 2 1 Vista panel posterior 3 2 2 Montaje en rack del SAI 3 2 3 Configuraci n del SAI 3 2 4 Substituici n de bater as 5 2 5 Kit de bater as 6 3 Operaciones 7 3 1 Botones de funcionamiento 7 3 2 Panel LCD 8 3 3 Alarma ac stica 9 3 4 Indicaci n del display LCD 9 3 5 Configuraci n SAI 10 3 6 Descripci n del modo operativo 13 3 7 C digo de fallo 14 3 8 Indicadores de advertencia 14 4 Soluci n de problemas 15 5 Almacenamiento y mantenimiento 17 6 Especificaciones 18 PHASE PH 9310 PH 9315 PH 9320 PH 9330 Seguridad y armon a ININTERRUMPIDA Sistema de Alimentaci n Ininterrumpida 1 Aviso importante sobre seguridad Siga estrictamente todas las advertencias e instrucciones de
4. 1 5K PH 9320 2K PH 9330 3K 1 Salidas programables conexi n a cargas no cr ticas 2 Conectores de salida conectar a las cargas cr ticas 3 Entrada de red AC corriente alterna 4 Disyuntor de entrada 5 Protecci n contra sobretensi n de red fax m dem 6 Conector con funci n de apagado de emergencia EPO Emergency Power Off 7 Puerto de comunicaci n USB 8 Puerto de comunicaci n RS 232 9 Slot inteligente SNMP 10 Conector de bater a externa var a en funci n del modelo 2 2 Montaje en Rack del SAI El SAl puede colocarse en un armario rack 19 Por favor siga las siguientes instrucciones para colocar el SAl en rack Paso 2 2 3 Configuraci n del SAI Paso 1 Conexi n de las bater as Por razones de seguridad el SAI viene embalado de fabrica con las baterias desconectadas Antes de conectar el SAI por favor siga los siguientes pasos para conectar las bater as Paso 1 Paso 2 Paso 3 Quite el panel frontal Conecte la entrada AC y reconecte Coloque nuevamente el las conexiones de las bater as panel frontal Paso 2 Conexi n de entrada al SAI Conecte el SAI nicamente a una toma de dos polos tres cables con toma a tierra Evite el uso de cables de extensi n Para los modelos de 208 220 230 240VAC el cable se suministra con el SAI Nota Para los modelos de baja tensi n Compruebe si el indicador de fallo de conexi n del panel LCD est encendido Se ilumina cuando el SAl e
5. Click ViewPower software icon and then choose your required OS to download the software 3 Follow the on screen instructions to install the software 4 When your computer restarts the monitoring software will appear as an orange plug icon located in the system tray near the clock Step 8 External battery connection Follow below chart to make external battery connection e PH 9310 PH 9315 PH 9320 PH 9330 RE Uninterruptable Power Supply ININTERRUPTA 2 Installation and setup ER 2 4 Battery replacement Notice This UPS is equipped with internal batteries and user can replace the batteries without shutting down the UPS or connected loads hot swappable battery design Replacement is a safe procedure isolated from electrical hazards CAUTION Consider all warnings cautions and notes before replacing batteries Note Upon battery disconnection equipment is not protected from power outages Remove front panel Remove the top cover of battery box and replace the inside batteries Step 7 Step 2 Disconnect battery wires Step 5 After replacing the batteries put the battery box back to original location and screw it tightly Put the front panel back to the unit Seguranca e harmonia ININTERRUPTA Step 3 Pull out the battery box by removing two screws on the front panel Step 6 be EE a RK e Ces Re connect the battery wires PH 9310 PH 9315 PH 9320 PH
6. La bater a no est aislada del circuito de la tensi n de entrada Puede haber voltajes peligrosos entre los terminales de la bater a y de la tierra Antes de tocar nada por favor compruebe que no haya tensi n e Las bater as pueden causar descargas el ctricas y cortocircuitos Por favor tome las precauciones abajo detalladas y cualquier otra medida necesaria cuando se trabaja con las bater as gt Eliminar los relojes anillos y otros objetos met licos gt Utilice s lo herramientas con asas y mangos aislados Cuando cambie las bater as instale la misma cantidad y el mismo tipo de bater as No intente tirar a la basura o quemar las bater as porque podr an explotar No abra o destruya las bater as El electrolito que se desprende puede da ar la piel y los ojos La bater a es t xica Por favor reemplace el fusible nicamente por otro del mismo tipo y amperaje para evitar riesgo de incendio No desmonte el SAI bajo ning n concepto NOTA Antes de la instalaci n por favor compruebe la unidad Aseg rese de que nada en el interior del embalaje est da ado Por favor mantenga el embalaje original en un lugar seguro para un futuro uso 2 PH 9310 PH 9315 PH 9320 PH 9330 PHASAM Seguridad y armon a Sistema de Alimentaci n Ininterrumpida ININTERRUMPIDA 2 Instalaci n y configuraci n 2 1 Vista panel posterior 1 NOD lt A daa PH 9310 1K PH 9315
7. o inersorbaa 18 x Tens o Entrada ata 02 x Curosaidainversor 14 GJ Teno Entrada bala 08 x gt gt Tenstobatenaata 27 GO Entrada nao balanceada 04 x Tens obatoratana 26 SS Erro arranque Inversor mn x Sobre aquecimento a x Tens o iwversorata 12 x Sens 4 a 3 8 Indicadores de alerta fe Tal lt i e A er y gt iG His Es Ari AU FAI Al Vii T UPS sobrecarregada Soando cada segundo A VP EPO activado Soando cada segundo Erro de ventila o Soando cada segundo Erro da carga da bateria 8 H N Soando cada segundo tens o PH 9310 PH 9315 PH 9320 PH 9330 Sistema de Alimenta o Ininterrupta ININTERRUMPIDA 4 Solu o de problemas Se o aparelho n o est a funcionar correctamente por favor tente resolver o problema usando a tabela abaixo Sintoma Sem indica o nem alarme mesmo se a energia est normal O cone e o c digo indica EP piscam no display LCD e o alarme soa cada segundo O cone A e Y piscam no display LCD e o alarme soa cada segundo O cone A e amp piscam no display LCD e o alarme soa cada segundo O erro indica o c digo 27 o cone pisca no display LCD e o alarme soa continuamente O erro indica o c digo 28 o cone pisca no display LCD e o alarme soa continuamente O cone e piscam no display LCD e o alarme soa duas vezes cada segundo O erro indica o c digo 43 o cone O
8. 5 145 VAC 5 0 290 VAC 5 SALIDA Rango sincronizado Rango frecuencia Modo bateria 50 Hz 0 2 Hz o 60 Hz 0 3 Hz Valor de corriente de cresta Distorsi n harm nica de ak 2 THD carga lineal 8 THD Modo bateria antes del apagado Tiempo Modo AC a bateria Cero trasfer Inverter a Bypass 4 ms Tipico EFICIENCIA BATERIA 12 V 9 AH 12 V 9 AH 12 V 9 AH Numero Tiempo recarga 4 horas para cargar al 90 de capacidad T pico Corriente de carga 1 0 A max Volt de carga 27 4 VDC 1 54 8 VDC 1 82 1 VDC 1 CARACTERISTICAS FISICAS Tipo bater a i Modelo Standard Torre CONDICIONES AMBIENTALES GESTI N Reducir la capacidad del SAI al 60 en la explotaci n de un convertidor de frecuencia y el 80 cuando el voltaje de salida se ha fijado en 200 208VAC PH 9310 PH 9315 PH 9320 PH 9330 PHASAN Sistema de Alimentaci n Ininterrumpida ININTERRUMPIDA INDICE 1 Aviso importante de seguran a lU 1 1 Transporte QD 1 2 Prepara o A 20 1 3 Instala o A 20 1 4 Funcionamento 20 1 5 Manuten o erepara o 20 2 Instala o e configura o di 2 1 Vista painel traseiro IIA 2 2 Instala o da UPS em Rack gt gt gt 2 2 1 Configura o da UPS e o 2 2 2 Substitui o das baterias 28 2 1 Kit de baterias opcional 24 3 Opera es 85 3 1 Bot es de funcionamento 25 3 2 Painel LCD D 3 3 Alarme ac stico
9. 9310 PH 9315 PH 9320 PH 9330 PHASAM Uninterruptable Power Supply Seguran a e harmonia ININTERRUPTA 3 Operations 04 ECO enable disable Parameter 3 Enable or disable ECO function You may choose the following two options ENA ECO mode enable DIS ECO mode disable 05 ECO voltage range setting Parameter 2 amp 3 Set the acceptable high voltage point and low voltage point for ECO mode by pressing Down key or Up key HI 5 d 5 Ver HLS High loss voltage in ECO mode in parameter 2 L LI For 208 220 230 240 VAC models the setting range in parameter 3 is from 7V to 24V of the nominal voltage LLS Low loss voltage in ECO mode in parameter 2 For 208 220 230 240 VAC models the setting range in parameter 3 is from 7V to 24V of the nominal voltage 06 Bypass enable disable when UPS is OFF Parameter 3 Enable or disable Bypass function You may choose the following two options ENA Bypass enable DIS Bypass disable 07 Bypass voltage range setting Parameter 2 amp 3 Set the acceptable high voltage point and acceptable low voltage point for Bypass mode by pressing the Down key or Up key HLS Bypass high voltage point For 208 220 230 240 VAC models 230 264 setting the high voltage point in parameter 3 from 230Vac to 264Vac LLS Bypass low voltage point For 208 220 230 240 VAC models 170 220 setting the low voltage point in parameter 3 from 170Vac to 220Vac PHASAIZ PH 9310 PH
10. 9315 PH 9320 PH 9330 Seguran a e harmonia ININTERRUPTA Uninterruptible Power Supply 3 Operations 08 Programmable outlets enable disable Parameter 3 Enable or disable programmable outlets ENA Programmable outlets enable DIS Programmable outlets disable 09 Programmable outlets setting Parameter 3 Set up backup time limits for programmable outlets 0 999 setting the backup time limits in minutes from 0 999 for programmable outlets which connect to non critical devices on battery mode 00 Exit setting PH 9310 PH 9315 PH 9320 PH 9330 PHASAN Uninterruptable Power Supply ININTERRUPTA 3 Operations 3 6 Operating Mode Description When the input voltage is within acceptable range UPS will d 3 9 we d 3 9 Online mode provide pure and stable AC power to output The UPS will e eur oureur also charge the battery at online mode O Ln E SN Energy saving mode CH vee pa ve ECO mode When the input voltage is within voltage regulation range E g3 eu i UPS will bypass voltage to output for energy saving O mo SS ra When input frequency is within 40 Hz to 70 Hz the UPS can d 3 o vac pa 30 Vac be set at a constant output frequency 50 Hz or 60 Hz The pa fpeur SE UPS will still charge battery under this mode When the input voltage is beyond the acceptable range or Battery mode power failure and alarm is sounding every 4 second UPS will backup power from battery When input
11. 9330 Uninterruptible Power Supply EN 2 Installation and setup 2 5 Battery kit assembly optional Notice Please assemble battery kit first before installing it inside of UPS Please select correct battery kit procedure below to assemble it 2 battery kit Step 1 Step 2 Step 3 Step 4 Remove adhesive tapes Connect all battery Put assembled battery packs Cover the other side of terminals by following on one side of plastic shells plastic shell as below upper chart and insert one more defect chart Then battery kit is battery on the space assembly well 4 battery kit Step 1 Step 2 Step 3 Tape Tape Remove adhesive tapes Connect all battery Put assembled battery packs Cover the other side of terminals by following on one side of plastic shells plastic shell as below upper chart chart Then battery kit is assembly well 6 battery kit Step 1 Step 2 Step 3 Tape ME Remove adhesive tapes Connect all battery Put assembled battery packs Cover the other side of terminals by following on one side of plastic shells plastic shell as below upper chart chart Then battery kitis assembly well PH 9310 PH 9315 PH 9320 PH 9330 Uninterruptable Power Supply ININTERRUPTA Seguran a e harmonia 3 Operations 3 1 Button operation e Turn on the UPS Press and hold ON Mute button for at least 2 seconds to turn on the UPS Mute the alarm When the UPS is on battery mode press and hold t
12. A A r s Fc Vac tensi n salida Vdc tensi n bater a Hz frecuencia Indica el nivel de carga 0 25 26 50 51 75 y 76 100 ses OVER LOAD Indica sobrecarga SHORT Indica un cortocircuito en la salida del SAI o en la carga conectada Indica que las tomas programables estan funcionando PH 9310 PH 9315 PH 9320 PH 9330 PHASAN Sistema de Alimentaci n Ininterrumpida ININTERRUMPIDA 3 Operaciones ES msmo OOOO y Indica que el circuito inverter est activo My mm am Indica las tomas de salida est n activas OP Indica el nivel de bater a 0 25 26 50 51 75 y 76 100 LOW BATT BATT Indica bajo nivel de bater a y baja tensi n de bater a Y aa vas Indica la tension de entrada frecuencia o tension de la bateria Vac tension de entrada impair ia He Vdc tension bateria Hz frecuencia de entrada 3 3 Alarma acustica 3 4 Indicacion del display LCD ss Soo Peshabilitado E o ooo MB ns ps En E a FA Reena i PH 9310 PH 9315 PH 9320 PH 9330 ININTERRUMPIDA Sistema de Alimentaci n Ininterrumpida 3 Operaciones 3 5 Configuraci n del SAI Par metro 1 Hay tres par metros de ajuste del SAI Par metro 1 opciones de programas Hay 9 programas a configurar Consulte la siguiente tabla El Par metro 2 y el Par metro 3 son las opciones de configuraci n o valores establecidos para cada programa Par metro 2 Par metro 3 01 Ajuste de la tensi n de s
13. Ininterrupta ININTERRUMPIDA 5 Armazenamento e manuten o Interven o A UPS cont m partes n o reutiliz veis A bateria tem uma vida de 3 a 5 anos a 25 C de temperatura ambiente Quando necessitar de substituir a bateria por favor contacte o Servi o de Assist ncia Armazenamento Se poss vel e por seguran a antes de armazenar a bateria carregue a por 5 horas Mantenha a UPS protegida e vertical num local seco e fresco Durante o armazenamento recarregue a bateria de acordo com a tabela seguinte Temperatura armazenamento Frequ ncia de recarregamento Dura o do carregamento 25 C 40 C 40 C 45 C PHASAM i PH 9310 PH 9315 PH 9320 PH 9330 ININTERRUMPIDA Sistema de Alimenta o Ininterrupta 6 Especifica es MODELO PH9310 PHo315 PH9320 PH9330 CAPACIDADE 1000 VA 800W 1500 VA 1200 W 2000 VA 1600 W 3000 VA 2400 W ENTRADA 160 VAC 140 VAC 120 VAC 110 VAC 5 o Tens o transier ncia baixo base em carga 100 80 80 70 70 60 60 0 Gama de tens o 170 VAC 150 VAC 130 VAC 120 VAC 5 150 VAC 5 ou 300 VAC 5 145 VAC 5 ou 290 VAC 5 Ae qUenda 48 Hz 52 Hz ou 58 Hz 62 Hz Gama sincronizada 50 Hz 0 2 Hz ou 60 Hz 0 3 Hz LA A Gama de pico actual 2 THD carga linear Distor o harmonica 8 THD Modo bateria antes de desligar Zero transfer ncia 4 ms T pico EFICI N
14. To oem inda 10 Amax PHYSICAL ENVIRONMENT MANAGEMENT Derate capacity to 60 of capacity in Frequency converter mode and to 80 when the output voltage is adjusted to 200 208VAC PH 9310 PH 9315 PH 9320 PH 9330 PHASAN Uninterruptable Power Supply ININTERRUPTA NOTAS NOTAS NOTES ns PH 9210 PH 9220 PH 9230 PH 9260 Seguran a e harmonia ININTERRUPTA PHASAM Seguridad y armon a ININTERRUMPIDA O 2013 PHASAK
15. essas duas op es CF ENA modo Converter ativado DIS CF modo Converter desativado 03 Configura o frequ ncia de sa da Par metros 2 e 3 configurar frequ ncia de sa da g 3 lt lt Pode se configurar a frequ ncia inicial no modo bateria BAT 50 Frequ ncia de sa da 50Hz fF Su BAT 60 Frequ ncia de saida 60Hz Se estiver no modo Converter pode se eleger entre as seguintes frequ ncias de saida CF 50 Frequ ncia de saida 50Hz CF 60 Frequ ncia de saida 60Hz O PH 9310 PH 9315 PH 9320 PH 9330 PHASAM Seguridad y armon a Sistema de Alimentac o Ininterrupta ININTERRUMPIDA 3 Opera es 04 ECO ativado desativado Par metro 3 Ativa ou desativa a fun o ECO poss vel eleger entre essas duas op es ENA Modo ECO ativado DIS Modo ECO desativado 05 ECO Ajuste do intervalo de tens o Par metros 2 e 3 Definir os limites aceit veis de alta e baixa tens o em modo ECO pressionando Down key ou Up key Hi 5 d 5 Var HLS Alta perda de tens o no modo ECO no par metro 2 ie LI Para modelos 208 220 230 240 Vac a gama de ajuste no par metro 3 7V a 24V da tens o nominal LLS Baixa perda de tens o no modo ECO no par metro 2 Para modelos 208 220 230 240 Vac a gama de ajuste no par metro 3 de 7V a 24V da tens o nominal 06 Bypass ativado desativado quando a UPS est desligada Par metro 3 Ativar ou desativar a fun o do bypass Pode se eleger
16. este manual Guarde este manual y lea atentamente las siguientes instrucciones antes de instalar la unidad No utilice este aparato sin antes leer con atenci n toda la informaci n sobre seguridad e instrucciones 1 1 Transporte Por favor transporte el SAl en la caja original para protegerlo de los posibles choques y golpes 1 2 Preparaci n Cuando el SAI pasa de un ambiente caliente a otro frio se puede crear condensaci n El equipo debe estar completamente seco antes de su instalaci n Por favor deje el SAI por lo menos dos horas para climatizarlo No instale el SAl cerca del agua o en ambientes h medos No instale el SAI expuesto a la luz solar directa o cerca de fuentes de calor No bloquee los orificios de ventilaci n del SAI 1 3 Instalaci n No conecte la toma de salida del SAI a dispositivos dispositivos que puedan sobrecargarlos por ejemplo impresoras l ser Coloque los cables de modo que no se puedan pisar o tropezar con ellos No conecte a la toma del SAI aparatos como secadores de pelo El SAI puede ser manejado por cualquier persona incluso sin experiencia Conecte el SAI nicamente a un enchufe con toma de tierra que sea f cilmente accesible y cercano al SAI de manera que no se pisotee el cable Por favor use s lo cables de alimentaci n con homologaci n VDE y CE para conectar el SAI a la toma de red con toma de tierra Use s lo cables de alimentaci n con homologaci n VDE y CE
17. para conectar las cargas al SAI Al instalar el SAI debe asegurarse de que la suma de la corriente de fuga del SAI y del equipo conectado no sea superior a 3 5mA 1 4 Funcionamiento No desconecte el cable de alimentaci n de SAI de lo contrario se anular la protecci n que la masa de tierra proporciona al SAl y a todas sus cargas El SAI tiene su propia de fuente de alimentaci n interna bater as En la toma de salida del SAI o terminales de voltaje de salida puede haber tensiones incluso si el SAl no est conectado a la red Para desconectar completamente el SAI presione el interruptor OFF Enter Impida la entrada de l quidos u objetos extra os al interior del SAI 1 5 Mantenimiento y reparaci n El SAI funciona con voltajes peligrosos Cualquier reparaci n debe ser realizada exclusivamente por personal cualificado e Precauci n Riesgo de descarga el ctrica Incluso despu s de desconectarse de la red el cableado interno contin a conectado a la bater a y la tensi n es peligrosa Antes de realizar cualquier tipo de servicio y o mantenimiento desconecte las bater as verificando que no haya corriente ni exista riesgo de voltaje incluidas las creadas por los condensadores de alta capacidad S lo las personas habilitadas para tratar con bater as y que lo hagan con las medidas y precauciones necesarias pueden sustituir las bater as y controlar las operaciones Precauci n Riesgo de descarga el ctrica
18. usar cabos de extens o Para os modelos de 208 220 230 240VAC o cabo fornecido com a UPS Nota Para os modelos de baixa tens o Verifique se o painel de LCD iluminado ou n o ou se indica uma falta de conex o Acende se quando o aparelho est conectado a uma tomada inadequada Consulte a tabela de solu o de problemas Passo 3 Liga o de sa da da UPS As tomadas de sa da s o de dois tipos gerais e program veis Conectar as cargas n o cr ticas s sa das program veis e os dispositivos cr ticos s sa das gerais Em caso de falha de energia a UPS pode ser programada para aumentar o tempo de backup para cargas cr ticas e para reduzir as cargas n o cr ticas e Para as UPS 3K siga os passos seguintes para aceder configura o dos terminais de entrada e sa da a Retire a tampa do bloco de terminais na parte traseira da UPS b Recomenda se o uso de cabos tipo AWG14 ou 2 1mm2 c Ap s a conclus o das liga es verifique se os cabos est o firmes d Recoloque a tampa do bloco de terminais PH 9310 PH 9315 PH 9320 PH 9330 ININTERRUMPIDA Sistema de Alimenta o Ininterrupta 2 Instala o e configura o Passo 3 Conectores de comunica o pode variar consoante o modelo Portas de comunica o Porta USB Porta RS 232 Slot Inteligente f G GG sl E la e on Para controlar a UPS atrav s do PC conecte o cabo de comunica o do PC a uma porta USB RS 232 da UPS Com o softwa
19. voltage is within acceptable range but UPS is F a Bypass mode overload UPS will enter bypass mode or bypass mode can CH La ger a be set by front panel Alarm is sounding every 10 second E T A 230 UPS is powered off and no output supply power but still can LI LI Standby mode INPUT outeur charge batteries Frequency Converter mode O PHASAM PH 9310 PH 9315 PH 9320 PH 9330 ININTERRUPTA Uninterruptible Power Supply 3 Operations 3 7 Faults Reference Code Fataen Faultcode icon Faultevent Faultcode icon Date Lan x invenervaltage tow Im x DO Bis 02 x _Irverteroutput short 14 DO sueros x Batey votaye too igh 2 ISS Bus unbalance oa x Battoryvotage toolow 28 SS inverter stan nm x Overtemperatare a xo verter votage gh 12 x Overload a O 3 8 Warning indicator Alarm Warning Icon flashing larm Low Battery Sounding every second Battery is not connected N Sounding every second SS Over Charge Sounding every second A Charger failure CH N Sounding every second range PH 9310 PH 9315 PH 9320 PH 9330 Uninterruptable Power Supply EE ra 4 Troubleshooting If the UPS system does not operate correctly please solve the problem by using the table below Symptom gt ossible cause Remedy The AC input power is not connected Check if input power cord firmly di well connected to the mains No i
20. 9315 PH 9320 PH 9330 Seguran a e harmonia ININTERRUPTA Uninterruptible Power Supply 3 Operations 3 2 LCD Panel Backup Fault Time Info Info Mute Input amp Battery Voltage Info Output amp Battery Voltage Info gt Load Info Wees ke Node Programmable Operation Info Outlet Info Indicates the backup time in pie chart H g Indicates the backup time in numbers S A H hours M minute S second lt lt A Indicates that the warning and fault occurs H H Indicates the warning and fault codes and the codes are listed in details in 3 5 a section Indicates that the UPS alarm is disabled H H H vac Indicates the output voltage frequency or battery voltage ane Vac output voltage Vdc battery voltage Hz frequency Q Indicates the load level by 0 25 26 50 51 75 and 76 100 OVER LOAD Indicates overload SHORT Indicates the load or the UPS output is short circuit Indicates that programmable management outlets are working PH 9310 PH 9315 PH 9320 PH 9330 Uninterruptable Power Supply ININTERRUPTA Seguran a e harmonia 3 Operations reee EE Indicates the Inverter circuit is working My Indicates the Battery level by 0 25 26 50 51 75 and 76 100 BATT FAULT FAULT Indicates the battery is fault LOW BATT BATT Indicates low battery level and low battery voltage Vac o g D Vide indicates the input voltage or frequency or battery
21. CIA BATERIA 12V 9AH 12V 9AH 12V 9AH N mero Tempo recarregamento 4 horas para carregar at 90 da capacidade T pico Corrente de carga 1 0 A max Tens o de carga 27 4 VDC 1 54 8 VDC 1 82 1 VDC 1 CARACTER STICAS F SICAS 410 x 437 x 84 mm 630 x 437 x 84 mm Medidas PXL XA Peso neto kg 16 31 CONDI ES AMBIENTAIS Humidade relativa sem condensa o 20 90 RH 0 40 C N vel de ru do lt 50dBA O 1 metro Tipo bateria i Modelo Standard Torre GEST O Smart RS 232 ou USB Suporta Windows 98 2000 2003 XP Vista 2008 7 Linux Unix e MAC SNMP Opcional Power management from SNMP manager and web browser Reduzir a capacidade da UPS a 60 em opera o de um conversor de frequ ncia e 80 quando a tens o de sa da fixado em 200 208VA PH 9310 PH 9315 PH 9320 PH 9330 PHASAN Sistema de Alimentac o Ininterrupta ININTERRUMPIDA TABLE OF CONTENTS ER 1 Important Safety Warning A 1 1 Transportation e AE 1 2 Preparation tC BB 1 3 Installation ISS 1 4 Operations A 1 5 Maintenance service and faults CCSS 2 Installation and setup CY 2 1 Rear panel view CY 2 2 Rack mounted the UPS CY 2 1 Setup the UPS AH 2 2 Battery replacement Ai 2 1 Battery kit assembly option 42 3 Operations AA 3 1 Button operation A 3 2 LCD Panel A 3 3 Audible Alarm SS 3 4 LCD display wordings index AN 3 5 UPS Setting GH 3 6 Operating Mo
22. H 9310 PH 9315 PH 9320 PH 9330 ININTERRUMPIDA Sistema de Alimenta o Ininterrupta Seguridad y armon a 2 Instala o e configura o 2 5 Kit de baterias adicional opcional AVISO Por favor monte o kit de baterias primeiro antes de o colocar na UPS Escolha o procedimento correcto dependendo do tipo de kit para colocar as baterias Kit de 2 baterias Passo 1 Passo 2 Passo 3 Passo 4 Remova as cintas adesivas Ligue todos os Coloque as baterias sobre Cubra o outro lado terminais das baterias um dos laterais da com a tampa do kit de tal como representado carca a de pl stico baterias no desenho Kit de 4 baterias Passo 1 Passo 2 Passo 3 Adesivos Adesivos Remova as cintas adesivas Ligue todos os Coloque as baterias sobre Cubra o outro lado terminais das baterias um dos laterais da com a tampa do kit de tal como representado carca a de pl stico baterias no desenho Kit de 6 baterias Passo 1 Passo 2 Passo 3 Passo 4 Adesivos Wa O Ka O lt Remova as cintas adesivas Ligue todos os Coloque as baterias sobre Cubra o outro lado terminais das baterias um dos laterais da com a tampa do kit de tal como representado carca a de pl stico baterias no desenho PH 9310 PH 9315 PH 9320 PH 9330 Sistema de Alimenta o Ininterrupta ININTERRUMPIDA Seguridad y armon a 3 Opera es 3 1 Bot es de funcionamento Liga a UPS Mantenha pressionada a
23. PS desligou se automaticamente devido sobrecarga da sa da da UPS Retire o excesso de carga ligada UPS e de seguida desligue e reinicie a UPS A UPS desligou se automaticamente devido a um curto circuito na sa da da UPS Verifique os cabos e se os dispositivos conectados sa da da UPS est o em curto circuito PHASAM Seguridad y armon a ININTERRUMPIDA PH 9310 PH 9315 PH 9320 PH 9330 Sistema de Alimentac o Ininterrupta 4 Solu o de problemas Houve uma falha interna do SAO Existem duas causas poss veis O erro indica o c digo 1 2 3 4 11 1 A carga est ligada mas 12 13 e 41 no display LCD e o directamente atrav s da rede utilizando alarme soa continuamente o bypass 2 Nenhuma electricidade fornecida carga Contacte o seu servi o de assist ncia Carregue a bateria durante pelo menos cinco horas e em seguida verifique a capacidade Se o problema persistir contacte o seu servi o de assist ncia ce Contacte o seu servico de assist ncia Bateria danificada ae para substituir a bateria O ventilador est bloqueado ou Verifique o ventilador e informe o seu danificado revendedor A bateria n o est completamente O tempo de autonomia inferior ao carregada valor nominal O cone e a advert ncia FA piscam no display LCD e o alarme soa cada segundo O PH 9310 PH 9315 PH 9320 PH 9330 PHASAM Seguridad y armon a Sistema de Alimentac o
24. VER LOAD pisca no display LCD e o alarme soa continuamente O erro indica o c digo 14 o cone SHORT pisca no display LCD e o alarme soa continuamente Canada DAR ara e causas FossivelS PRO E gf Calima s 3JOlUCAO A entrada de alimentac o AC n o est bem conectada Verifique se o cabo de alimentac o est conectado a rede A entrada AC de alimentac o est ligada a sa da da UPS Conecte o cabo de alimenta o a entrada AC da UPS Ajuste o encerramento do circuito A fun o EPO est activada para desactivar o EPO Os cabos de linha e neutro da entrada da UPS est o invertidos Rode a tomada 180 e ligue a UPS As baterias internas ou externas n o est o bem conectadas Verifique se todas as baterias est o correctamente conectadas A tens o da bateria muito baixa ou falha do carregador Contacte o seu servico de assist ncia A tens o da bateria muito baixa ou falha do carregador Contacte o seu servico de assist ncia A UPS est sobrecarregada Ge o excesso de carga ligada A UPS est sobrecarregada Os dispositivos conectados UPS s o alimentados directamente da rede atrav s do bypass Retire o excesso de carga ligada UPS Ap s sobrecarga repetida a UPS est bloqueada no modo bypass Os dispositivos ligados UPS alimentam se directamente na rede Retire o excesso de carga ligada UPS e de seguida desligue e reinicie a UPS A U
25. a alarma suena continuamente El icono y parpadean en el display LCD y la alarma suena dos veces cada segundo El error indica el c digo 43 el icono parpadea en el display LCD y la alarma suena continuamente El error indica el c digo 14 el icono parpadea en el display LCD y la alarma suena continuamente La entrada de red CA no est bien conectada La entrada de red CA est conectada a la salida del SAI La funci n EPO est activada Los cables de l nea y neutro de la entrada del SAI est n invertidos Las bater as internas o externas no est n bien conectadas El voltaje de la bater a es demasiado alto o el cargador falla El voltaje de la bater a es demasiado bajo o falla el cargador SAI est sobre cargado El SAl est sobrecargado Los dispositivos conectados en SAI son alimentados directamente de la red a trav s de bypass Despu s de repetidas sobrecargas el SAI est bloqueado en modo bypass Los dispositivos conectados al SAI se alimentan directamente de la red El SAl se ha apagado autom ticamente debido a la sobrecarga de salida del SAI El SAI se ha apagado autom ticamente como resultado de corto circuito a la salida del SAI Compruebe si el cable de alimentaci n de entrada est conectado a la red Conecte el cable de alimentaci n de entrada a la entrada AC del SAI Ajuste el cierre del circuito por desactivar la funci n EPO Ro
26. a alimenta o normal no modo AC pressione Bot es ON Mute simultaneamente os bot es ON Mute e Select por 5 segundos e a UPS mudar para Select modo bypass Esta fun o n o poss vel quando a tens o de entrada est fora da faixa aceit vel PHASAM PH 9310 PH 9315 PH 9320 PH 9330 ININTERRUMPIDA Sistema de Alimentac o Ininterrupta 3 Opera es 3 2 Painel LCD Informa o Informa o de autonomia de erro Informa o de alarme Informa o tens o de entrada e bateria Informa o tens o de sa da e bateria Informa o da bateria encenar ana gt Informa o de carga Informa o Informa o do modo operativo das sa das program veis 8 Indica o tempo de autonomia com rel gio anal gico Indica o tempo de autonomia com rel gio digital H horas M minutos S segundos Indica um alarme de aten o e de erro Indica o c digo de aviso e de erro conforme detalhado na sec o 3 5 Indica que o alarme sonoro est desactivado H H Vde Indica a tens o de sa da frequ ncia ou voltagem da bateria a Nz Vac tens o sa da Vdc tens o bateria Hz frequ ncia Indica o n vel de carga 0 25 26 50 51 75 e 76 100 ses OVER LOAD Indica sobrecarga SHORT Indica um curto circuito na saida da UPS ou no equipamento conectado Indica que as tomadas programaveis estao a trabalhar PH 9310 PH 9315 PH 9320 PH 9330 PHASAN Sistema de Alimen
27. a para las tomas programables 0 999 ajusta el tiempo de autonom a durante el modo bater a de O a 999 minutos para las salidas programables conectadas a dispositivos no cr ticos 00 Ajustes de salida PHASAM PH 9310 PH 9315 PH 9320 PH 9330 Sistema de Alimentaci n Ininterrumpida ININTERRUMPIDA 3 Operaciones 3 6 Descripci n del modo operativo Cuando el voltaje de entrada est dentro del rango bs ii aceptable el SAl proporcionar una corriente alterna CA a e 3 LI o 3 Ls Modo Online Ee INPUT oureur de salida limpia y estable Al mismo tiempo el SAI carga la bater a en modo online Eh LU E Modo de ahorro energ a E W Cuando el voltaje de entrada est dentro del rango d HH d 3 O Modo ECO INPUT OUTPUT aceptable el SAI funciona en bypass sacando el mismo E voltaje de entrada para ahorrar energ a OB Hai Cuando la frecuencia de entrada est entre 40 Hz y 70 Hz vac ee el SAI puede ser programado con una frecuencia de salida g J HH c3 LI constante a 50 Hz o 60 Hz En este modo el SAI contin a cargando la bateria Cuando la tensi n de entrada est fuera del rango aceptable Voda batera o hay un fallo de alimentaci n el SAI emite un sonido de alarma cada 4 segundos El SAI se mantendr activo hasta que termina la autonom a de la bater a Cuando el voltaje de entrada es aceptable pero el SAI est Modo Bypass sobrecargado el SAI entrar en modo bypass o se puede
28. alar o software 4 Quando reiniciar o PC o software apresentado como um cone laranja no canto inferior de ecr no tabuleiro do sistema perto do rel gio Passo 8 Conex o da bateria externa Para a conex o de bateria externa veja a figura seguinte A PH 9310 PH 9315 PH 9320 PH 9330 PHASAN Sistema de Alimentac o Ininterrupta ININTERRUMPIDA 2 Instala o e configura o 2 4 Substitui o das baterias Nota A UPS est equipada com bateria internas e o utilizador pode substitui las sem ser necess rio desligar os equipamentos ligados extra o das baterias a quente ATENC O A substitui o um procedimento seguro e livre de perigos no entanto tenha em aten o todas as advert ncias precau es e notas antes de substituir as baterias Nota Ao desligar a bateria o equipamento ficar desprotegido contra cortes de energia Passo 1 Passo 2 Passo 3 Remova o painel frontal Desligue os cabos de Remova os dois parafusos bateria colocados no chassi do painel frontal e retire a caixa das baterias Passo 4 Passo 5 Passo 6 EE b a LE q ELEH SE gegen Remova a tampa superior da Ap s substituir as baterias Volte a ligar os cabos caixa de baterias e substitua coloque a caixa de baterias de bateria as baterias que se encontram no seu lugar e volte a dentro da caixa apertar os parafusos removidos no passo 3 Passo 7 Coloque novamente o painel frontal P
29. alida Voltaje de salida Par metro 3 Para los modelos 208 220 230 240 VAC se puede elegir el voltaje de salida siguiente 208 la tensi n de salida es de 208Vac 220 la tensi n de salida es de 220Vac 230 la tensi n de salida es de 230Vac 240 la tensi n de salida es de 240Vac 02 Convertidor de Frecuencia habilitado desactivado Par metros 2 y 3 Activa o desactiva el modo convertidor Es posible elegir entre las dos opciones siguientes CF ENA modo convertidor activado DIS CF modo de convertidor desactivado 03 Configuraci n frecuencia de salida 03 ee Par metro 2 y 3 configurar frecuencia de salida Puede configurar la frecuencia inicial en modo bateria rm E 5 BAT 50 Frecuencia de salida a 50Hz L BAT 60 Frecuencia de salida a 60Hz Si est en modo convertidor puede elegir entre las siguientes frecuencias de salida CF 50 Frecuencia de salida a 50Hz CF 60 Frecuencia de salida a 60Hz PH 9310 PH 9315 PH 9320 PH 9330 PHASAN Sistema de Alimentaci n Ininterrumpida ININTERRUMPIDA 3 Operaciones 04 ECO habilitado desactivado Par metro 3 Activa o desactiva la funci n de la ECO Puede elegir entre las siguientes dos opciones ENA Modo ECO activado DIS Modo ECO desactivado 05 ECO Ajuste del rango de voltaje Par metros 2 y 3 Ajuste los l mites aceptables de alta y baja tensi n en modo ECO pulsando Down key o Up key HI 5 db Var HLS Alta p rdida de tensi
30. ater as coloque la caja de cables de bater a las bater as que se encuentran bater as en su lugar de dentro de la caja origen yatornille los 2 tornillos que quit en el paso 3 Paso 7 Coloque nuevamente el panel frontal A gl PH 9310 PH 9315 PH 9320 PH 9330 ININTERRUMPIDA Sistema de Alimentaci n Ininterrumpida Es 2 Instalaci n y configuraci n 2 5 Kit de bater as adicional opcional AVISO Por favor ensamble el kit de bater as primero antes de colocarlo en el SAI Seleccione el procedimiento correcto dependiendo del tipo de kit para colocar las bater as Kit de 2 bater as Paso 1 Paso 2 Paso 3 Paso 4 Quite las cintas adhesivas Conecte todos los Coloque las bater as sobre Cubra el otro lado terminales de las bater as uno de los laterales de la con la tapa del kit de tal como se muestra carcasa de pl stico bater as en el gr fico Kit de 4 bater as Paso 1 Paso 2 Paso 3 Paso 4 Adhesivos Ka e O lt Quite las cintas adhesivas Conecte todos los Coloque las bater as sobre Cubra el otro lado terminales de las bater as uno de los laterales de la con la tapa del kit de tal como se muestra carcasa de pl stico bater as en el gr fico Kit de 6 bater as Paso 1 Paso 2 Paso 3 Adhesivos E Ka 2 jo lt Quite las cintas adhesivas Conecte todos los Coloque las bater as sobre Cubra el otro lado terminales de las bater as uno de los laterales de la con la tapa del
31. atus monitoring connect the communication cable one end to the USB RS 232 port and the other to the communication port of your PC With the monitoring software installed you can schedule UPS shutdown start up and monitor UPS status through PC The UPS is equipped with intelligent slot perfect for either SNMP or AS400 card When installing either SNMP or AS400 card in the UPS it will provide advanced communication and monitoring options Note USB port and RS 232 port can t work at the same time Step 4 Network connection varies depending on the model Network Fax Phone surge ports Step 5 Disable and enable EPO function varies depending on the model Keep the pin 1 and pin 2 closed for UPS normal operation To activate EPO function cut the wire between pin 1 and pin 2 It s in closed status for UPS normal operation Step 6 Turn on the UPS Press the ON Mute button on the front panel for two seconds to power on the UPS Note The battery charges fully during the first five hours of normal operation Do not expect full battery run capability during this initial charge period Step 7 Install software For optimal computer system protection install UPS monitoring software to fully configure UPS shutdown You may insert provided CD into CD ROM to install the monitoring software If not please follow steps below to download and install monitoring software from the internet 1 Go to the website http www phasak com descargas 2
32. cia La bateria no est completamente El tiempo de autonom a es m s cargada breve del valor nominal El icono y el aviso FA parpadean en el display LCD y la alarma suena cada segundo O PH 9310 PH 9315 PH 9320 PH 9330 PHASAM Seguridad y armon a Sistema de Alimentaci n Ininterrumpida ININTERRUMPIDA 5 Almacenamiento y mantenimiento Mantenimiento El SAI contine partes no reutilizables La bater a tiene una vida de 3 5 a os a 25 C de temperatura ambiente Cuando tengan que ser sustituidos por favor p ngase en contacto con su servicio asistencia Almacenamiento Si es posible y por seguridad antes de almacenarla cargue la bater a durante 5 horas Mantenga el SAI protegido y en posici n vertical en un lugar seco y fresco Durante el almacenamiento recargue la bater a de acuerdo con el siguiente cuadro Temperatura almacenaje Frecuencia de recarga Duraci n de la carga 25 C 40 C 40 C 45 C PHASE PH 9310 PH 9315 PH 9320 PH 9330 ININTERRUMPIDA Sistema de Alimentaci n Ininterrumpida 6 Especificaciones MODELO PHesto PH9315 nam PH9330 CAPACIDAD 1000 VA 800W 1500 VA 1200W 2000 VA 1600 W 3000 VA 2400 W ENTRADA 160 VAC 140 VAC 120 VAC 110 VAC 5 O base en carga 100 80 80 70 70 60 60 0 Volt transferencia baja Rango Volt 170 VAC 150 VAC 130 VAC 120 VAC 5 150 VAC 5 o 300 VAC
33. configurar este modo bypass desde el panel frontal Cada 10 segundos el SAI emite una alarma Cuando el SAI se apaga no alimenta la salida pero tambi n carga la bater a Modo de conversi n de frecuencia PHASAM PH 9310 PH 9315 PH 9320 PH 9330 ININTERRUMPIDA Sistema de Alimentaci n Ininterrumpida O CET 3 7 C digo de fallo Volt Entrada alto Corto inverter salida Volt Entrada bajo Volt bater aalto Entrada no balanceada Volt Bater a bajo Error arranque Inverter Sobrecalentamiento 3 8 Indicadores de advertencia SAI sobrecargado Sonido cada segundo A Error de carga de bateria 8 H N Sonido cada segundo Bypass ere Batangas Sonido cada segundo de voltaje PH 9310 PH 9315 PH 9320 PH 9330 Sistema de Alimentaci n Ininterrumpida ININTERRUMPIDA 4 Soluci n de problemas Si el SAI no funciona correctamente por favor resuelva utilizando el cuadro siguiente Sin indicaci n ni alarma incluso si la alimentaci n es normal El icono el c digo indica EP parpadenado en el display LCD y la alarma suena cada segundo EL icono y Y parpadean en el display LCD y la alarma suena cada segundo EL icono y El parpadean en el display LCD y la alarma suena cada segundo El error indica el c digo 27 el icono parpadea en el display LCD y la alarma suena continuamente El error indica el c digo 28 el icono parpadea en el display LCD y l
34. ct pausa de 10 segundos Modo de configuraci n Pulse el bot n durante 5 segundos para entrar en modo de ajustes con el SAl en modo espera o bypass Down key presione este bot n para seleccionar la siguiente opci n de configuraci n de SAI Cambia a modo bypass Cuando la alimentaci n es normal modo AC pulse Botones simult neamente los botones ON Mute y Select durante 5 segundos y el SAl entrar ON Mute Select en modo bypass Esta funci n no ser posible cuando el voltaje de entrada est fuera un rango aceptable Bot n OFF Enter PHASE PH 9310 PH 9315 PH 9320 PH 9330 Seguridad y armon a ININTERRUMPIDA Sistema de Alimentaci n Ininterrumpida 3 Operaciones 3 2 Panel LCD Informaci n Informaci n de autonomia de error Informaci n del alarma Informaci n tensi n d Informaci n tensi n de entrada y bateria de salida y bater a eee vac Informaci n O E D Hz de bater a OUTPUT gt Informaci n de carga Informaci n Informaci n del modo operativo de las salidas programables 8 Indica el tiempo de autonom a con reloj anal gico Indica el tiempo de autonom a con reloj digital H horas M minutos S segundos Indica una alarma de aviso y de error Indica el c digo del aviso y del error detallados en la secci n 3 5 Indica que la alarma sonora est deshabilitada H H e Indica la tensi n de salida frecuencia o tensi n bater a Hz
35. de Description CY 3 7 Faults Reference Code D 3 8 Warning indicator CSD 4 Troubleshooting gt o S O Oad 9 Storage and Maintenance DA 6 Specifications O PH 9310 PH 9315 PH 9320 PH 9330 ININTERRUMPIDA Uninterruptible Power Supply Seguridad y armon 1 Important Safety Warning Please comply with all warnings and operating instructions in this manual strictly Save this manual properly and read carefully the following instructions before installing the unit Do not operate this unit before reading through all safety information and operating instructions carefully 1 1 Transportation Please transport the UPS system only in the original package to protect against shock and impact 1 2 Preparation Condensation may occur if the UPS system is moved directly from cold to warm environment The UPS system must be absolutely dry before being installed Please allow at least two hours for the UPS system to acclimate the environment Do not install the UPS system near water or in moist environments Do not install the UPS system where it would be exposed to direct sunlight or near heater Do not block ventilation holes in the UPS housing 1 3 Installation Do not connect appliances or devices which would overload the UPS system e g laser printers to the UPS output sockets Place cables in such a way that no one can step on or trip over them Do not connect domestic appliances such as hair drye
36. ed in the Bypass mode Connected output first Then shut down the UPS devices are fed directly by the mains and restart it Fault code is shown as 43 and the The UPS shut down automatically icon is lighting on LCD display because of overload at the UPS output and alarm is continuously sounding Remove excess loads from UPS output and restart it The UPS shut down automatically because short circuit occurs on the Check output wiring and if connected UPS output devices are in short circuit status Fault code is shown as 14 and the icon is lighting on LCD display and alarm is continuously sounding PHASAN PH 9310 PH 9315 PH 9320 PH 9330 ININTERRUPTA Uninterruptible Power Supply 4 Troubleshooting A UPS internal fault has occurred There are two possible results 1 The load is still supplied but directly from AC power via bypass 2 The load is no longer supplied by power Fault code is shown as 1 2 3 4 11 12 13 and 41 on LCD display and alarm is continuously sounding Contact your dealer Charge the batteries for at least 5 hours and then check capacity If the Battery backup time is shorter than problem still persists consult your nominal value dealer Batteries defect Contact your dealer to replace the battery Fan is locked or not working Batteries are not fully charged The iconA and the warning codeF A flashing on LCD display and alarm is sounding every second Check fans and noti
37. entre as seguintes duas op es ENA Bypass ativado DIS Bypass desativado 07 Configura o da gama de tens o do Bypass Fr Vee 4 Par metros 2 e 3 Ajuste os limites aceit veis de alta e baixa tens o para operar no modo bypass pressionando a tecla Up ou Down HLS Bypass limite de alta tens o Modelos 208 220 230 240 VAC 230 264 O limite de alta tens o no par metro 3 230Vac a 264Vac LLS Bypass limite de baixa tens o Modelos 208 220 230 240 VAC 170 220 O limite de baixa tens o no par metro 3 170Vac a 220Vac PH 9310 PH 9315 PH 9320 PH 9330 ININTERRUMPIDA Sistema de Alimenta o Ininterrupta Seguridad y armon a 3 Opera es 08 Sa das program veis ativadas desativadas Par metro 3 Sa das program veis ativadas ou desativadas ENA Sa das program veis ativadas DIS Sa das program veis desativadas 09 Configura o das sa das program veis Par metro 3 Fixa os limites do tempo de autonomia das tomadas program veis 0 999 ajusta o tempo de autonomia durante o modo bateria de O a 999 minutos para as sa das program veis conectadas aos dispositivos n o cr ticos 00 Ajustes de sa da O PH 9310 PH 9315 PH 9320 PH 9330 PHASAI Sistema de Alimenta o Ininterrupta ININTERRUMPIDA 3 Opera es 3 6 Descri o do modo de opera o Quando a tens o de entrada est dentro do intervalo Ste pe aceit vel a UPS fornece uma corrente a
38. fy dealer PH 9310 PH 9315 PH 9320 PH 9330 Uninterruptable Power Supply ININTERRUPTA Seguran a e harmonia 5 Storage and Maintenance Operation The UPS system contains no user serviceable parts If the battery service life 3 5 years at 25 C ambient temperature has been exceeded the batteries must be replaced In this case please contact your dealer Storage Before storing charge the UPS 5 hours Store the UPS covered and upright in a cool dry location During storage recharge the battery in accordance with the following table Storage Temperature Recharge Frequency Charging Duration 40 C 45 C Every 2 months PH 9310 PH 9315 PH 9320 PH 9330 ININTERRUPTA Uninterruptible Power Supply Seguran a e harmonia 6 Specifications MODEL PH9310 PHo315 PH9320 PH9330 CAPACITY 1000 VA 800W 1500 VA 1200 W 2000 VA 1600 W 3000 VA 2400 W INPUT 160 VAC 140 VAC 120 VAC 110 VACz 5 based on load carga 100 80 80 70 TO 60 60 0 Low Line Transfer Voltage Range 170 VAC 150 VAC 130 VAC 120 VAC 5 150 VAC 5 or 300 VAC 5 145 VAC 5 or 290 VAC 5 OUTPUT Synchronized Range 50 Hz 0 2 Hz or 60 Hz 0 3 Hz LA eh Current Crest Ratio 2 THD linear load Harmonic Distortion 8 THD Bat mode before shut down Zero rasto ms Typical EFFICIENCY BATTERY 12 V 9 AH Numbers 2 o 4
39. his button for at least 5 seconds to disable or enable the alarm system But it s not applied to the situations when warnings or errors occur Up key Press this button to display previous selection in UPS setting mode e Switch to UPS self test mode Press ON Mute buttons simultaneously for 5 seconds to enter UPS self testing while in AC mode ECO mode or converter mode ON Mute Button Turn off the UPS Press and hold this button at least 2 seconds to turn off the UPS in battery mode UPS will be in standby mode under power normal or transfer to OFF Enter Button Bypass mode if the Bypass enable setting by pressing this button Confirm selection key Press this button to confirm selection in UPS setting mode e Switch LCD message Press this button to change the LCD message for input voltage input frequency battery voltage output voltage and output frequency It will return back to default display when pausing for 10 seconds Setting mode Press and hold this button for 5 seconds to enter UPS setting mode when UPS is in standby mode or bypass mode Down key Press this button to display next selection in UPS setting mode Select Button e Switch to bypass mode When the main power is normal press ON Mute and Select ON Mute Select l E Button buttons simultaneously for 5 seconds Then UPS will enter to bypass mode This action will be ineffective when the input voltage is out of acceptable range PHASAIZ PH 9310 PH
40. kit de tal como se muestra carcasa de pl stico bater as en el gr fico PH 9310 PH 9315 PH 9320 PH 9330 Sistema de Alimentaci n Ininterrumpida ININTERRUMPIDA Seguridad y armon a 3 Operaciones 3 1 Botones de funcionamiento Enciende el SAI Mantenga pulsada la tecla ON Mute durante 2 segundos para encender el SAI Silenciar la alarma Cuando el SAl entra en modo de bater a mantenga pulsada la tecla durante al menos 5 segundos para activar o desactivar el sistema de alarma No es aplicable en caso de error o advertencias Up key pulse este bot n para mostrar la selecci n anterior en el modo configuraci n del SAI Cambio a modo de auto prueba Estando en modo AC modo ECO o modo convertidor mantenga pulsado el bot n de ON Mute durante 5 segundos para entrar en auto prueba Bot n ON Mute Apagar el SAI Pulse el bot n durante 2 segundos para desactivar el SAI en modo bater a Presionando este bot n el SAl se pone en modo de espera estando con alimentaci n normal o cambia a modo bypass si el bypass lo permite Bot n de confirmaci n de la selecci n presione este bot n para confirmar un ajuste en el modo configuraci n del SAI Cambio de mensaje en LCD Pulse este bot n para cambiar el mensaje del LCD para el voltaje de entrada la frecuencia de entrada el voltaje de la bater a el voltaje de salida y la frecuencia de salida El LCD vuelve a la vista por defecto tras una Bot n Sele
41. l sistema operativo OS para transferir el software a su PC 3 Siga las instrucciones en la pantalla del monitor para instalar el software 4 Cuando reinicie su PC ver un icono de color naranja en el rea de notificaciones cerca del reloj de su PC abajo a la derecha Paso 9 Conexi n de la bater a externa Para la conexi n de bater a externa v ase la siguiente figura PH 9310 PH 9315 PH 9320 PH 9330 PHASE Seguridad y armon a Sistema de Alimentaci n Ininterrumpida ININTERRUMPIDA 2 Instalaci n y configuraci n 2 4 Substituici n de bater as Nota El SAl est equipado con bater as internas y el usuario puede reemplazarlas sin necesidad de desconectar las cargas conectadas al SAI extracci n de bater as en caliente PRECAUCI N La sustituci n es un procedimiento seguro y desprovisto de peligros electricos a n as tome en consideraci n todas las advertencias precauciones y notas antes de reemplazar las baterias Nota Al desconectar la bater a el equipo queda desprotegido contra cortes de energ a Paso 1 Paso 2 Paso 3 Quite el panel frontal Desconecte los cables de Quite los 2 tornillos colocados bater a en el chasis del panel frontal y saque lacaja de bater as hacia fuera Paso 5 Paso 6 EN Liik a ll K LE mf Cf gegen Quite la tampa superior de la Despu s de reemplazar las Conecte nuevamente los caja de bater as y reemplace b
42. lternada CA a e 3 LI o 3 Ls Modo Online E INPUT OUTPUT sa da limpa e est vel Ao mesmo tempo a UPS carrega a bateria em modo online A LU E Modo poupan a de energia 30 230 Quando a tens o de entrada est dentro do intervalo LI L Modo ECO o Ze INPUT OUTPUT aceit vel a UPS opera em bypass tirando a mesma tens o E de entrada para economizar energia ODE a Quando a frequ ncia de entrada est entre 40 Hz e 70 Hz a vec va Modo de convers o de UPS pode ser programada com uma frequ ncia de sa da E g J HH c3 Ls frequ ncia constante de 50 Hz ou 60 Hz Neste modo a UPS continua a carregar a bateria Quando a tens o de entrada est fora do intervalo aceit vel ou se houver uma falha de energia o aparelho emite um Modo bateria Ei i alarme a cada 4 segundos A UPS permanecer activa at ao final da vida til da bateria Quando a tens o de entrada aceit vel mas a UPS est Vodo Bynas sobrecarregada entra em modo bypass ou esse modo yP bypass pode ser definido a partir do painel frontal A cada 10 segundos o aparelho emite um alarme A UPS est desligada e n o fornece alimenta o no Modo Espera entanto carrega as baterias PHASAI PH 9310 PH 9315 PH 9320 PH 9330 ININTERRUMPIDA Sistema de Alimenta o Ininterrupta 3 Opera es 3 7 C digo de erro causa datana N ero cone Causadafalha Nero leone Mao m energia o1 x Tens
43. n en modo ECO en el par metro 2 ie LI Para modelos 208 220 230 240 Vac el rango de ajuste en el par metro 3 es 7V a 24V la tensi n nominal LLS Baja p rdia de tensi n en modo ECO en el par metro 2 Para modelos 208 220 230 240 Vac el rango de ajuste en el par metro 3 es de 7V a 24V voltaje nominal 06 Bypass activado desactivado cuando el SAI est OFF Par metro 3 Activar o desactivar la funci n del bypass Puede elegir entre las siguientes dos opciones ENA Bypass activado DIS Bypass desactivado 07 Configuraci n del rango de voltaje del Bypass Fr Vee 4 Parametros 2 y 3 Ajuste los limites aceptables de alto y bajo voltaje para funcionar en modo de bypass pulsando las teclas Down key o Up key HLS Bypass limite de alta tension Modelos 208 220 230 240 VAC 230 264 el limite de alta tension en el parametro 3 es de 230Vac a 264Vac LLS By pass limite de baja tension Modelos 208 220 230 240 VAC 170 220 el limite de baja tension en el parametro 3 es de 170Vac a 220Vac PH 9310 PH 9315 PH 9320 PH 9330 ININTERRUMPIDA Sistema de Alimentaci n Ininterrumpida Seguridad y armon a 3 Operaciones 08 Salidas programables activadas desactivadas Par metro 3 Salidas programables activadas o desactivadas ENA Salidas programadas activadas DIS Salida previstas son desactivadas 09 Configuraci n de salidas programables Par metro 3 Fija los l mites del tiempo de autonom
44. ndication and alarm even though the mains is normal SEN The AC input is connected to the UPS Plug AC input power cord to AC input output correctly The icon and the warning EP code flashing on LCD display and EPO function is activated alarm is sounding every second Set the circuit in closed position to disable EPO function The icon A and Y flashing on LCD display and alarm is sounding every second Line and neutral conductors of UPS Rotate mains power socket by 180 input are reversed and then connect to UPS system The icon and flashing on LCD display and alarm is sounding every second The external or internal battery is Check if all batteries are connected incorrectly connected well Fault code is shown as 27 and the icon is lighting on LCD display and alarm is continuously sounding Battery voltage is too high or the charger is fault Contact your dealer Fault code is shown as 28 and the icon is lighting on LCD display and alarm is continuously sounding Battery voltage is too low or the charger is fault UPS is overload Remove excess loads from UPS output UPS is overloaded Devices connected to the UPS are fed directly by the The icon and is flashing electrical network via the Bypass on LCD display and alarm is sounding twice every second Contact your dealer Remove excess loads from UPS output After repetitive overloads the UPS is Remove excess loads from UPS lock
45. ndido apagado del SAI y controlar su estado a trav s del PC El SAI est equipado con una ranura slot para tarjetas inteligentes AS400 o SNMP para tener una comunicaci n avanzada o una mejor opci n de controlar el SAl USB y RS 232 no pueden funcionar simult neamente Paso 5 Conectar red puede var ar en funci n del modelo Puertos de protecci n Red Fax M dem vele Paso 6 Habilitar y deshabilitar la funci n EPO puede variar en funci n del modelo Para el funcionamiento normal del SAl mantener cerrado los pines 1 y 2 Para activar la funci n EPO mantener abiertos los pines 1 y 2 Habitualmente apagado para el funcionamiento normal del SA Paso 7 Encender el SAI Pulse el interruptor ON Mute de la parte frontal durante 2 segundos para encender SAI Nota La bater a se carga por completo en 5 horas de funcionamiento normal del SAl No realice experimentos de descargas de la bater a durante el periodo de la carga ni espere tener la bater a a pleno rendimiento durante el periodo de carga inicial Paso 8 Instalar el software Para una protecci n ptima del sistema instale el software de control del SAl en su PC para configurar el apagado del SAI Inserte el CD suministrado en la unidad CD Rom para instalar el software de control Si no siga los siguientes pasos para descargar el software de internet 1 Introducci n de la p gina web http www phasak com descargas 2 Haga clic en ViewPower y elija e
46. nua incluindo aqueles criados por capacitadores de alta capacidade Somente pessoas autorizadas dever o lidar com as baterias e devem faz lo com cuidado e precau o podem substituir as baterias e controlar as opera es Pessoas n o autorizadas n o devem ter contacto com as baterias Cuidado Risco de choque el ctrico A bateria n o est isolada do circuito da tens o de entrada Podem existir tens es perigosas entre os terminais da bateria e da terra Antes de tocar em qualquer coisa certifique se que n o existe tens o As baterias podem causar choque el ctrico e curtos circuitos Por favor tome todas as precau es e quaisquer outras medidas necess rias quando trabalhar com as baterias gt Remova rel gios an is e outros objectos de metal gt Use somente ferramentas com cabos isolantes Ao mudar as baterias utilize o mesmo n mero e tipo de baterias N o deite fora ou queime as baterias Estas podem explodir N o abra nem manipule a bateria O eletr lito que liberta prejudicial para a pele e para os olhos N o destrua as baterias A bateria pode ser t xica Por favor substitua o fus vel somente com o mesmo tipo e amperagem para preven o de inc ndios N o desmonte a UPS em qualquer circunst ncia NOTA Antes da instala o por favor revise a unidade Assegure se de que n o existe nenhum item danificado no interior da embalagem Por favor mantenha a embalagem original em um lugar segu
47. ores de cabelo A UPS pode ser gerida por qualquer pessoa mesmo sem experi ncia Conecte a UPS a uma tomada com terra de f cil acesso e pr ximo UPS de modo a n o pisar o cabo Por favor utilize unicamente cabos de alimenta o com homologa o VDE e CE para ligar a UPS a rede com tomada de terra Utilize apenas os cabos de alimenta o com a marca CE e com testes VDE para conectar os equipamentos a UPS Durante a instala o deve garantir que a soma da corrente de fuga da UPS e dos equipamentos conectados n o excede 3 5mA 1 4 Funcionamento N o desligue o cabo de alimenta o da UPS sob pena de cancelar a massa de terra que fornece o equipamento e todos os equipamentos ligados e A UPS tem a sua pr pria fonte de energia interna bateria Pode haver tens es na sa da da UPS ou nos terminais de tens o de sa da mesmo que a UPS n o esteja conectada rede Para desligar completamente a UPS pressione o bot o OFF Enter Evite a entrada de l quidos ou objectos estranhos dentro da UPS 1 5 Manuten o e repara o A UPS opera com voltagens perigosas As repara es devem ser realizadas por pessoal qualificado Cuidado Risco de choque el ctrico Mesmo depois de se desligar da rede os cabos internos permanecem conectados bateria e a tens o perigosa Antes de qualquer tipo de servi o e ou manuten o desligue a bateria e verifique se h qualquer risco de tens o de corrente cont
48. pe and amperage in order to avoid fire hazards Do not dismantle the UPS system NOTE Before installation please inspect the unit Be sure that nothing inside the package is damaged Please keep the original package in a safe place for future use 38 PH 9310 PH 9315 PH 9320 PH 9330 PHASAIK Seguran a e harmonia Uninterruptable Power Supply ININTERRUPTA 2 Installation and setup 2 1 Rear panel view 1 e _ _ __ gt o daa PH 9310 1K PH 9315 1 5K PH 9320 2K PH 9330 3K 1 Programmable outlets connect to non critical loads 2 Output receptacles connect to mission critical loads 3 AC input 4 Input circuit breaker 5 Network Fax Modem surge protection 6 Emergency power off function connector EPO 7 USB communication port 8 RS 232 communication port 9 SNMP intelligent slot 10 External battery connection depends on the model 2 2 Rack Mounted the UPS This UPS can be mounted in the 19 rack chassis Please follow below steps to position this UPS Step 2 2 3 Setup the UPS Step 1 Connect battery wires For safety consideration the UPS is shipped out from factory without connecting battery wires Before install the UPS please follow below steps to re connect battery wires first Step 1 Step 2 Step 3 ES pe Ee Remove front panel Connect the AC input and Put the front panel back re connect battery wires to the unit
49. re de controlo instalado no seu PC voc pode definir de ligar desligar a UPS e monitorizar a estado atrav s do PC A UPS est equipada com uma ranhura slot para placas inteligentes AS400 ou SNMP para uma comunica o avan ada ou melhor op o de controlo da UPS Nota As portas USB e RS 232 n o podem trabalhar em simult neo Passo 4 Ligar a rede pode variar consoante o modelo Portas de protec o Rede Modem Telefone Passo 5 Activar e desactivar a fun o EPO pode variar consoante o modelo Para o funcionamento normal da UPS mantenha fechados os pinos 1 e 2 Para activar o EPO manter abertos os pinos tez Normalmente fechado para o funcionamento normal do UPS Passo 6 Ligar a UPS Pressione o bot o ON Mute na frente por 2 segundos para ligar a UPS Nota A bateria est completamente carregada em 5 horas de funcionamento normal da UPS N o fa a experi ncias de descarregar a bateria durante a carga N o espere que a bateria esteja na plena capacidade durante a carga inicial Passo 7 Instalar o software Para uma ptima protec o do sistema instale o software de monitoriza o no seu PC para configurar a UPS Insira o CD no CD ROM para instalar o software de controlo Se n o siga estes passos para fazer o download do software da internet 1 Visite o site Web http www phasak com descargas 2 Clique no ViewPower e seleccione o seu sistema operativo OS 3 Siga as instru es no ecr para inst
50. ro para uso futuro PH 9310 PH 9315 PH 9320 PH 9330 PHASE Sistema de Alimenta o Ininterrupta ININTERRUMPIDA 2 Instala o e configura o 2 1 Vista traseira 1 Tee em _ daa PH 9310 1K PH 9315 1 5K PH 9320 2K PH 9330 3K 1 Terminais de sa da program vel conectar a cargas n o cr ticas 2 Conectores de sa da conectar a cargas cr ticas 3 Tomada de entrada de electricidade 4 Disjuntor de entrada 5 Protec o contra sobrecargas em rede fax modem 6 Conector para a fun o de fecho de emerg ncia EPO Desligar de emerg ncia 7 Porta de comunica o USB 8 Porta de comunica o RS 232 9 Slot Inteligente placas SNMP Web e AS400 10 Conector de bateria externa varia consoante o modelo 2 2 Instala o da UPS em Rack A UPS pode ser colocada num Arm rio Rack de 19 Por favor siga as seguintes instru es para colocar a UPS num Rack Passo 1 Passo 2 2 3 Configurac o da UPS Passo 1 Conex o das baterias Por raz es de seguran a a UPS vem embalada de f brica com as baterias desconectadas Antes de ligar a UPS por favor siga os passos seguintes para conectar as baterias Passo 1 Passo 2 Passo 3 Desmonte o painel frontal Conecte a entrada AC e reconecte Coloque novamente o as conex es das baterias painel frontal Passo 2 Liga o a entrada da UPS Ligue a UPS a uma tomada da parede de dois p los e tr s fios terra Evite
51. rs to UPS output sockets The UPS can be operated by any individuals with no previous experience Connect the UPS system only to an earthed shockproof outlet which must be easily accessible and close to the UPS system Please use only VDE tested CE marked mains cable e g the mains cable of your computer to connect the UPS system to the building wiring outlet shockproof outlet Please use only VDE tested CE marked power cables to connect the loads to the UPS system When installing the equipment it should ensure that the sum of the leakage current of the UPS and the connected devices does not exceed 3 5mA 1 4 Operation Do not disconnect the mains cable on the UPS system or the building wiring outlet shockproof socket outlet during operations since this would cancel the protective earthing of the UPS system and of all connected loads The UPS system features its own internal current source batteries The UPS output sockets or output terminals block may be electrically live even if the UPS system is not connected to the building wiring outlet In order to fully disconnect the UPS system first press the OFF Enter button to disconnect the mains Prevent no fluids or other foreign objects from inside of the UPS system 1 5 Maintenance service and faults The UPS system operates with hazardous voltages Repairs may be carried out only by qualified maintenance personnel Caution risk of electric shock Even after
52. st enchufado a una toma de red inapropiada Consulte la resoluci n de problemas Instale tambi n por favor un disyuntor 40A entre la red y la entrada AC en los modelos de 3K para un uso seguro Paso 3 Conexi n de salida del SAI e Las tomas de salida son de dos tipos tomas de corriente generales y enchufes programables Conecte las cargas no cr ticas a las salidas programables y los dispositivos cr ticos a las tomas generales En caso de fallo el ctrico puede programar el SAl para aumentar el tiempo de autonom a a las cargas cr ticas y reducirlo para las cargas no cr ticas Para los SAI 3K siga los pasos abajo detallados para acceder a la configuraci n de los terminales de entrada y salida a Quitar la tapita del bloque de terminales en la parte trasera del SAI b Se recomienda el uso de cableado tipo AWG14 o 2 1mmz2 c Al concluir las conexiones compruebe que los cables est n bien sujetos d Vuelva a colocar la tapita del bloque de terminales PH 9310 PH 9315 PH 9320 PH 9330 ININTERRUMPIDA Sistema de Alimentaci n Ininterrumpida 2 Instalaci n y configuraci n Paso 4 Conectores de comunicaci n puede variar en funci n del modelo Puertos de comunicaci n Puerto USB Puerto RS 232 Slot Inteligente f G GG e 1 Para controlar el SAI por medio del PC conecte el cable de comunicaci n desde el PC a un puerto USB RS 232 del SAI Con el software de control instalado en su PC puede programar el ence
53. tac o Ininterrupta ININTERRUMPIDA 3 Opera es IEA ass nm A Indica que a invers o do circuito est activa Ny Di Wi Indica que as tomadas de sa da est o activas SP Indica o n vel da bateria 0 25 26 50 51 75 e 76 100 LOW BATT BATT Indica bateria baixa e baixa tens o da bateria ai ide aria OE vdc Indica entrada de tens o frequ ncia ou tens o da bateria impair ai He Vac tens o de entrada Vdc tens o bateria Hz frequ ncia de entrada 3 3 Alarme ac stico 3 4 Indica o do display LCD Do o dE edo T se A E Zi TE Baixa perda EE DORA o FR O ear i PH 9310 PH 9315 PH 9320 PH 9330 ININTERRUMPIDA Sistema de Alimenta o Ininterrupta 3 Opera es 3 5 Configura o da UPS Par metro 1 H tr s par metros ajust veis da UPS Par metro 1 As op es de programa H 9 programas para configurar Veja a tabela Os par metros 2 e 3 s o as defini es ou valores estabelecidos para cada programa Par metro 2 Par metro 3 01 Ajuste da tens o de sa da Tens o de sa da Par metro 3 Para os modelos 208 220 230 240 VAC pode se escolher a tens o de sa da seguinte 208 a tens o de sa da 208Vac 220 a tens o de sa da 220Vac 230 a tens o de sa da 230Vac 240 a tens o de sa da 240Vac 02 Conversor de Frequ ncia ativado desativado Par metros 2 e 3 Ativa ou desativa o modo Converter poss vel eleger entre
54. tar la toma el ctrica 180 y conectar al SAI Compruebe si todas las baterias est n bien conectadas P ngase en contacto con su servicio asistencia P ngase en contacto con su servicio asistencia Eliminar el exceso de carga conectado al SAI Eliminar el exceso de carga conectado al SAI Eliminar el exceso de carga conectado al SAI Despu s apague y reinicie el SAI Eliminar el exceso de carga conectado al SAI Despu s apague y reinicie el SAI Comprobar el cableado y silos dispositivos conectados a la salida del SAI est n en cortocircuito PH 9310 PH 9315 PH 9320 PH 9330 Sistema de Alimentaci n Ininterrumpida Seguridad y armon a ININTERRUMPIDA 4 Soluci n de problemas Ha ocurrido un fallo interno de SAI Hay dos posibles causas El c digo de error indica 1 2 3 4 1 La carga est en funcionamiento 11 12 13 y 41 en el display LCD y pero directamente a trav s de la red la alarma suena continuamente mediante el bypass 2 No se suministra electricidad a la carga P ngase en contacto con su servicio asistencia Cargar la bater a durante al menos 5 horas y luego comprobar la capacidad Si el problema persiste p ngase en contacto con el servicio de asistencia P P ngase en contacto con su servicio Bater a da ada l e asistencia para sustituir la bater a El voltaje de la bater a es demasiado P ngase en contacto con su servicio alto o el cargador falla asisten
55. tecla de ON Mute por 2 segundos para ligar a UPS Para silenciar o alarme quando a UPS entra em modo de bateria pressione por pelo menos 5 segundos para activar ou desactivar o sistema de alarme N o se Bot o ON Mute aplica em caso de erro ou avisos i Up key pressionar este bot o para mostrar a selec o pr via no modo de configura o da UPS Mudan a no modo de auto teste simultaneamente pressione o bot o ON Mute por 5 segundos para entrar no auto teste enquanto no modo AC modo ECO ou conversor de modo Desligar a UPS Mantenha pressionada a tecla de ON Mute por 2 segundos para desactivar a UPS em modo bateria Ao pressionar este bot o o aparelho colocado em modo de espera se houver alimenta o ou muda a modo bypass se o bypass Bot o OFF Enter permitir Bot o de confirma o de selec o pressione este bot o para confirmar um ajuste do modo de configura o da UPS Mudan a LCD Mensagem Clique neste bot o para alterar a mensagem do LCD para a tens o de entrada frequ ncia de entrada tens o de bateria tens o de sa da e frequ ncia de sa da O LCD retorna visualiza o inicial ap s uma pausa de 10 Bot o Select get S Modo configura o Pressione o bot o por 5 segundos para entrar no modo de configura o com a UPS em modo de espera ou bypass Down key pressione este bot o para seleccionar a pr xima op o de configura o da UPS Muda para modo bypass Quando
56. the unit is disconnected from the mains building wiring outlet components inside the UPS system are still connected to the battery and electrically live and dangerous Before carrying out any kind of service and or maintenance disconnect the batteries and verify that no current is present and no hazardous voltage exists in the terminals of high capability capacitor such as BUS capacitors e Only persons are adequately familiar with batteries and with the required precautionary measures may replace batteries and supervise operations Unauthorized persons must be kept well away from the batteries e Caution risk of electric shock The battery circuit is not isolated from the input voltage Hazardous voltages may occur between the battery terminals and the ground Before touching please verify that no voltage is present Batteries may cause electric shock and have a high short circuit current Please take the precautionary measures specified below and any other measures necessary when working with batteries gt remove wristwatches rings and other metal objects gt use only tools with insulated grips and handles When changing batteries install the same number and same type of batteries Do not attempt to dispose of batteries by burning them This could cause battery explosion Do not open or destroy batteries Escaping electrolyte can cause injury to the skin and eyes It may be toxic Please replace the fuse only with the same ty
57. voltage meee va aud Vac Input voltage Vdc battery voltage Hz input frequency 3 3 Audible Alarm ran Contimuousipsoundna O 3 4 LCD display wordings index Abbreviation Display content Wem Do dE ae IN E rem oe A es Da oo HO o rg PH 9310 PH 9315 PH 9320 PH 9330 ININTERRUPTA Uninterruptible Power Supply 3 Operations 3 5 UPS Setting Parameter 1 Parameter 2 Parameter 3 01 Output voltage setting There are three parameters to set up the UPS Parameter 1 It s for program alternatives There are 9 programs to set up Refer to the table Parameter 2 and parameter 3 are the setting options or values for each program Parameter 3 Output voltage For 208 220 230 240 VAC models you may choose the following output voltage 208 present output voltage is 208Vac 220 present output voltage is 220Vac 230 present output voltage is 230Vac 240 present output voltage is 240Vac Parameter 2 amp 3 Enable or disable converter mode You may choose the following two options CF ENA converter mode enable CF DIS converter mode disable Parameter 2 amp 3 Output frequency setting You may set the initial frequency on battery mode BAT 50 present output frequency is 50Hz BAT 60 present output frequency is 60Hz If converter mode is enabled you may choose the following output frequency CF 50 present output frequency is 50Hz CF 60 present output frequency is 60Hz O PH