User Manual PH 9210 / 20 / 30 / 60

image

Contents

1. poss vel eleger entre essas duas op es ENA Modo ECO activado DIS Modo ECO desactivado Par metros 2 e 3 Definir os limites aceit veis de alta e baixa tens o em modo ECO pressionando Down key ou Up key HLS Alta perda de tens o no modo ECO no par metro 2 Para modelos 208 220 230 240 Vac a gama de ajuste no par metro 3 7V a 24V da tens o nominal LLS Baixa perda de tens o no modo ECO no par metro 2 Para modelos 208 220 230 240 Vac a gama de ajuste no par metro 3 de 7V a 24V da tens o nominal Par metro 3 Activar ou desactivar a fun o do bypass Pode se eleger entre as duas op es seguintes ENA Bypass activado DIS Bypass desactivado Par metros 2 e 3 Ajuste os limites aceit veis de alta e baixa tens o para operar no modo bypass pressionando a tecla Up ou Down HLS Bypass limite de alta tens o Modelos 208 220 230 240 VAC 230 264 O limite de alta tens o no par metro 3 230Vac a 264Vac LLS Bypass limite de baixa tens o Modelos 208 220 230 240 VAC 170 220 O limite de baixa tens o no par metro 3 170Vac a 220Vac PHASAM PH 9210 PH 9220 PH 9230 PH 9260 ININTERRUMPIDA Sistema de Alimenta o Ininterrupta 3 Opera es 08 Sa das program veis activadas desactivadas Par metro 3 Sa das program veis activadas ou desactivadas ENA Sa das program veis activadas DIS Sa das program veis desactivadas Par metro 3 Fixa os limites d
2. 4 Conector da baterias externas varia mediante o modelo 5 Protec o contra sobrecargas em rede fax modem 6 Slot inteligente de porta RS 232 SNMP ou USB opcionais 7 Terminais de sa da 8 Disjuntor de sa da 2 2 Configura o da UPS Passo 1 Liga o a entrada da UPS e Ligue a UPS a uma tomada da parede de dois p los e tr s fios terra Evite usar cabos de extens o e Para os modelos de 208 220 230 240VAC o cabo fornecido com a UPS Nota Para os modelos de baixa tens o Verifique se o painel de LCD iluminado ou n o ou se indica uma falta de conex o Acende se quando o aparelho est conectado a uma tomada inadequada Consulte a tabela de solu o de problemas Passo 2 Liga o de sa da da UPS e As tomadas de sa da s o de dois tipos gerais e program veis Conectar as cargas n o cr ticas as sa das program veis e os dispositivos cr ticos s sa das gerais Em caso de falha de energia a UPS pode ser programada para aumentar o tempo de backup para cargas cr ticas e para reduzir as cargas nao criticas e Para as UPS 6K siga os passos seguintes para aceder configura o dos terminais de entrada e sa da a Retire a tampa do bloco de terminais na parte traseira da UPS b Recomenda se o uso de cabos tipo AWG14 ou 2 1mm2 c Ap s a conclus o das liga es verifique se os cabos est o firmes d Recoloque a tampa do bloco de terminais PH 9210 PH 9220 PH 9230 PH 9260 ININTERRUMPIDA
3. PH 9260 ININTERRUMPIDA Sistema de Alimenta o Ininterrupta Seguridad y armonia 1 Aviso de seguran a importante Siga rigorosamente todos os avisos e instru es deste manual Guarde este livro e leia atentamente as seguintes instru es antes de instalar a unidade N o utilize este aparelho sem ler atentamente todas as informa es e instru es de seguran a 1 1 Transporte e Por favor transporte a UPS na caixa original para a proteger contra poss veis choques e pancadas 1 2 Prepara o e Quando a UPS passa de um ambiente quente a um ambiente frio pode criar condensa o O equipamento deve estar completamente seco antes da instala o Por favor deixe a UPS pelo menos duas horas em ambiente quente e N o instale a UPS perto de gua ou em ambientes h midos e N o instale a UPS exposta a luz solar directa ou fontes de calor e N o cubra as sa das de refrigera o da UPS 1 3 Instala o e N o ligue a sa da da UPS a dispositivos que a podem sobrecarregar impressoras a laser por exemplo e Coloque os cabos de forma a que n o possa trope ar ou serem pisados e N o ligue as tomadas da UPS equipamentos como secadores de cabelo e A UPS pode ser gerida por qualquer pessoa mesmo sem experi ncia e Conecte a UPS a uma tomada com terra de f cil acesso e pr ximo a UPS de modo a n o pisar o cabo e Por favor utilize unicamente cabos de alimenta o com homologa o VDE e CE para ligar a UPS a rede
4. Seguridad y armonia ININTERRUMPIDA 1000 2000 SAI ONLINE 3000 UPS ONLINE 6000 ONLINE UPS Manual de uso Manual de utiliza o User Manual Sistema de Alimentaci n Ininterrumpida Sistema de Alimentac o Ininterrupta Uninterruptible Power Supply PH 9210 PH 9220 PH 9230 PH 9260 2013 PHASAK PHASAM Seguridad y armon a ININTERRUMPIDA o ESPANOL PORTUGU S ES INGL S PH 9210 PH 9220 PH 9230 PH 9260 Hat Sistema de Alimentaci n Ininterrumpida ININTERRUMPIDA INDICE EM 1 Aviso importante sobre seguridad 2 1 1 Transporte 2 1 2 Preparaci n 2 1 3 Instalaci n D 1 4 Funcionamiento 2 1 5 Mantenimiento y reparaci n 2 2 Instalaci n y configuraci n 3 2 1 Vista panel posterior 3 2 2 Configuraci n del SAI 3 3 Operaciones 5 3 1 Botones de funcionamiento 5 3 2 Panel LCD 6 3 3 Alarma ac stica 7 3 4 Indicaci n del display LCD 7 3 5 Configuraci n SAI 8 3 6 Descripci n del modo operativo 11 3 7 C digo de fallo 12 3 8 Indicadores de advertencia 12 4 Soluci n de problemas 13 5 Almacenamiento y mantenimiento 15 6 Especificaciones 16 PHASAIZ PH 9210 PH 9220 PH 9230 PH 9260 Seguridad y armonia ININTERRUMPIDA Sistema de Alimentaci n Ininterrumpida 1 Aviso importante sobre seguridad Siga estrictamente todas las advertencias e instrucciones de este manual Guarde este manual y lea atentamente las siguientes instrucciones antes de instala
5. PH 9260 ININTERRUMPIDA Sistema de Alimentaci n Ininterrumpida 2 Instalaci n y configuraci n Paso 3 Conectores de comunicaci n puede variar en funci n del modelo Puertos de comunicaci n Puerto USB Puerto RS 232 Slot Inteligente EFTTA Jo Para controlar el SAI por medio del PC conecte el cable de comunicaci n desde el PC a un puerto USB RS 232 del SAI Con el software de control instalado en su PC puede programar el encendido apagado del SAI y controlar su estado a trav s del PC El SAl est equipado con una ranura slot para tarjetas inteligentes AS400 o SNMP para tener una comunicaci n avanzada o una mejor opci n de controlar el SAI Paso 4 Conectar red puede var ar en funci n del modelo Puertos de protecci n Red Fax M dem n alo our Paso 5 Habilitar y deshabilitar la funci n EPO puede variar en funci n del modelo Para el funcionamiento normal del SAI mantener cerrado los pines 1 y 2 Para activar la funcion EPO mantener abiertos los pines 1 y 2 Habitualmente apagado para el funcionamiento normal del SAI Paso 6 Encender el SAI Pulse el interruptor ON Mute de la parte frontal durante 2 segundos para encender SAI Nota La bater a se carga por completo en 5 horas de funcionamiento normal del SAl No realice experimentos de descargas de la bater a durante el periodo de la carga ni espere tener la bater a a pleno rendimiento durante el periodo de carga inicial Paso 7 In
6. com tomada de terra e Utilize apenas os cabos de alimenta o com a marca CE e com testes VDE para conectar os equipamentos a UPS e Durante a instala o deve garantir que a soma da corrente de fuga da UPS e dos equipamentos conectados n o excede 3 5mA 1 4 Funcionamento e N o desligue o cabo de alimenta o da UPS sob pena de cancelar a massa de terra que fornece o equipamento e todos os equipamentos ligados e A UPS tem a sua pr pria fonte de energia interna bateria Podem haver tens es na sa da da UPS ou nos terminais de tens o de sa da mesmo que a UPS n o esteja conectada rede e Para desligar completamente a UPS pressione o bot o OFF Enter e Evite a entrada de l quidos ou objectos estranhos dentro da UPS 1 5 Manuten o e repara o e A UPS opera com voltagens perigosas As repara es devem ser realizadas por pessoal qualificado e Cuidado Risco de choque el ctrico Mesmo depois de se desligar da rede os cabos internos permanecem conectados bateria e a tens o perigosa e Antes de qualquer tipo de servi o e ou manuten o desligue a bateria e verifique se h qualquer risco de tens o de corrente cont nua incluindo aqueles criados por capacitadores de alta capacidade e Somente pessoas autorizadas dever o lidar com as baterias e devem faz lo com cuidado e precau o podem substituir as baterias e controlar as opera es Pessoas n o autorizadas n o devem ter contacto com as baterias
7. e Cuidado Risco de choque el ctrico A bateria n o est isolada do circuito da tens o de entrada Podem existir tens es perigosas entre os terminais da bateria e da terra Antes de tocar em qualquer coisa certifique se que n o existe tens o e As baterias podem causar choque el ctrico e curto circuitos Por favor tome todas as precau es e quaisquer outras medidas necess rias quando trabalhar com as baterias gt Remova rel gios an is e outros objectos de metal gt Use somente ferramentas com cabos isolantes e Ao mudar as baterias utilize o mesmo n mero e tipo de baterias e N o deite fora ou queime as baterias Estas podem explodir e N o abra nem manipule a bateria O eletrolito que liberta prejudicial para a pele e para os olhos N o destrua as baterias A bateria pode ser t xica e Por favor substitua o fus vel somente com o mesmo tipo e amperagem para preven o de inc ndios e N o desmonte a UPS em qualquer circunst ncia NOTA Antes da instala o por favor revise a unidade Assegure se de que n o existe nenhum item danificado no interior da embalagem Por favor mantenha a embalagem original em um lugar seguro para uso futuro PH 9210 PH 9220 PH 9230 PH 9260 PHASAN Sistema de Alimentac o Ininterrupta ININTERRUMPIDA 2 Instala o e configura o 2 1 Vista traseira PH 9210 1K PH 9220 2K PH 9230 3K PH 9260 6K 1 Tomadas de sa da 2 EntradaAC 3 Disjuntor
8. n es normal El icono el c digo indica EP parpadenado en el display LCD y la alarma suena cada segundo EL icono y Y parpadean en el display LCD y la alarma suena cada segundo EL icono y Blparpadean en el display LCD y la alarma suena cada segundo El error indica el c digo 27 el icono parpadea en el display LCD y la alarma suena continuamente El error indica el c digo 28 el icono parpadea en el display LCD y la alarma suena continuamente El icono y parpadean en el display LCD y la alarma suena dos veces cada segundo El error indica el codigo 43 el icono parpadea en el display LCD y la alarma suena continuamente El error indica el codigo 17 el icono parpadea en el display LCD y la alarma suena continuamente PHASAM 4 Soluci n de problemas La entrada de red CA no est bien conectada La entrada de red CA est conectada a la salida del SAI La funci n EPO est activada Los cables de l nea y neutro de la entrada del SAl est n invertidos Las bater as internas o externas no est n bien conectadas El voltaje de la bater a es demasiado alto o el cargador falla El voltaje de la bater a es demasiado bajo o falla el cargador El SAI est sobrecargado Los dispositivos conectados en SAI son alimentados directamente de la red a trav s de bypass Despu s de repetidas sobrecargas el SAI est bloqueado en modo bypass Los dispositivos conectados al
9. LCD Informaci n Informaci n de autonomia de error Informaci n del alarma Informaci n tensi n de entrada y bater a Informaci n tensi n de salida y bater a Informaci n de bater a gt Informaci n de carga Informaci n Informaci n del modo operativo de las salidas programables _ e Indica el tiempo de autonom a con reloj anal gico OE Indica el tiempo de autonomia con reloj digital S ufa H horas M minutos S segundos Indica una alarma de aviso y de error Indica el c digo del aviso y del error detallados en la secci n 3 5 A Indica que la alarma sonora est deshabilitada g i Indica la tensi n de salida frecuencia o tensi n bater a AE Vac tensi n salida Vdc tensi n bater a Hz frecuencia Indica el nivel de carga 0 25 26 50 51 75 y 76 100 oer Low LOAD Indica sobrecarga SHORT Indica un cortocircuito en la salida del SAI o en la carga conectada Indica que las tomas programables estan funcionando PH 9210 PH 9220 PH 9230 PH 9260 PHASAN Sistema de Alimentaci n Ininterrumpida ININTERRUMPIDA 3 Operaciones ZA Indica que el circuito inverter est activo mm a Indica las tomas de salida est n activas Indica el nivel de bater a 0 25 26 50 51 75 y 76 100 BATT FAULT FAULT Indica un error en la bateria LOW BATT BATT Indica bajo nivel de bater a y baja tensi n de bater a Va s sr i 7 7 o E vue Indica la tensi n de e
10. LCD display and alarm is sounding every second Check fans and notify dealer PH 9210 PH 9220 PH 9230 PH 9260 Uninterruptable Power Supply ININTERRUPTA Seguran a e harmonia 5 Storage and Maintenance Operation The UPS system contains no user serviceable paris If the battery service life 3 5 years at 25 C ambient temperature has been exceeded the batteries must be replaced In this case please contact your dealer Storage Before storing charge the UPS 5 hours Store the UPS covered and upright in a cool dry location During storage recharge the battery in accordance with the following table Storage Temperature Recharge Frequency Charging Duration PH 9210 PH 9220 PH 9230 PH 9260 ININTERRUPTA Uninterruptible Power Supply Seguran a e harmonia 6 Specifications MODEL pHo Prozo PHo20 PHozso CAPACITY 1000 VA 800W 2000 VA 1600 W 3000 VA 2400 W 6000 VA 4200 W 160VAC 140VAC 120VAC 110VAC 5 based on load 100 80 80 70 70 60 60 0 Low Line Transfer Voltage Range Low Line Comeback High Line Transfer High Line Comeback 175 VAC 5 or 85 VAC 5 300 VAC 5 or 150 VAC 5 290 VAC 5 or 145 VAC 5 Frequency Range 40Hz 70 Hz Single phase with ground 0 99 220 230 VAC or 110 120 VAC Output voltage 208 220 230 240VAC AC Voltage Regulation Batt Mode 3 Frequency Range Synchronized
11. SAI se alimentan directamente de la red El SAI se ha apagado autom ticamente debido a la sobrecarga de salida del SAI El SAI se ha apagado autom ticamente como resultado de corto circuito a la salida del SAI Compruebe si el cable de alimentaci n de entrada est conectado a la red Conecte el cable de alimentaci n de entrada a la entrada AC del SAI Ajuste el cierre del circuito por desactivar la funci n EPO Rotar la toma el ctrica 180 y conectar al SAI Compruebe si todas las baterias est n bien conectadas P ngase en contacto con su servicio asistencia P ngase en contacto con su servicio asistencia Eliminar el exceso de carga SAI est sobre cargado iecada A Eliminar el exceso de carga conectado al SAI Eliminar el exceso de carga conectado al SAI Despu s apague y reinicie el SAI Eliminar el exceso de carga conectado al SAI Despu s apague y reinicie el SAI Comprobar el cableado y si los dispositivos conectados a la salida del SAI estan en cortocircuito PH 9210 PH 9220 PH 9230 PH 9260 Sistema de Alimentacion Ininterrumpida Seguridad y armonia ININTERRUMPIDA 4 Soluci n de problemas Ha ocurrido un fallo interno de SAI Hay dos posibles causas El c digo de error indica 1 2 3 4 1 La carga esta en funcionamiento 11 12 13 y 41 en el display LCD y pero directamente a traves de la red la alarma suena continuamente mediante el bypass 2 No se
12. Sistema de Alimenta o Ininterrupta 2 Instala o e configura o Passo 3 Conectores de comunica o pode variar consoante o modelo Portas de comunica o Porta USB Porta RS 232 Slot Inteligente E F E AS yO Para controlar a UPS atrav s do PC conecte o cabo de comunica o do PC a uma porta USB RS 232 da UPS Com o software de controlo instalado no seu PC voc pode definir de ligar desligar a UPS e monitorizar o estado atrav s do PC A UPS est equipada com uma ranhura slot para placas inteligentes AS400 ou SNMP para uma comunicac o avan ada ou melhor op o de controlo da UPS Nota As portas USB e RS 232 n o podem trabalhar em simult neo Passo 4 Ligar a rede pode variar consoante o modelo Portas de protecc o Rede Modem Telefone cd a Passo 5 Activar e desactivar a fun o EPO pode variar consoante o modelo Para o funcionamento normal da UPS mantenha fechados os pinos 1 e 2 Para activar o EPO manter abertos os pinos tez Normalmente fechado para o funcionamento normal da UPS Passo 6 Ligar a UPS Pressione o bot o ON Mute na frente por 2 segundos para ligar a UPS Nota A bateria est completamente carregada em 5 horas de funcionamento normal da UPS N o fa a experi ncias de descarregar a bateria durante a carga N o espere que a bateria esteja na plena capacidade durante a carga inicial Passo 7 Instalar o software Para uma ptima protec o do sistema insta
13. de carga Informa o Informa o do modo operativo das sa das program veis _ O Indica o tempo de autonomia com rel gio anal gico OE Indica o tempo de autonomia com rel gio digital S ufa H horas M minutos S segundos Indica um alarme de aten o e de erro Indica o c digo de aviso e de erro conforme detalhado na sec o 3 5 A Indica que o alarme sonoro est desactivado g i Indica a tens o de sa da frequ ncia ou voltagem da bateria hpt iep Vac tens o sa da Vdc tens o bateria Hz frequ ncia Indica o n vel de carga 0 25 26 50 51 75 e 76 100 oer Low LOAD Indica sobrecarga SHORT Indica um curto circuito na saida da UPS ou no equipamento conectado Indica que as tomadas programaveis estao a trabalhar PH 9210 PH 9220 PH 9230 PH 9260 PHASAN Sistema de Alimentac o Ininterrupta ININTERRUMPIDA 3 Opera es ZA Indica que a invers o do circuito est activa mm a Indica que as tomadas de sa da est o activas Indica o n vel da bateria 0 25 26 50 51 75 e 76 100 na LOW BATT Indica bateria baixa e baixa tens o da bateria Var A i a E Vdc Indica entrada de tens o frequ ncia ou tens o da bateria E a HE Vac tens o de entrada Vdc tens o bateria Hz frequ ncia de entrada 3 3 Alarme ac stico 3 4 Indica o do display LCD Dem 0 ERRO O aco Do d o O edo De o ES O es 3 PH 9210 PH 9220 PH 9230 PH 9260 INI
14. direct sunlight or near heater e Do not block ventilation holes in the UPS housing 1 3 Installation e Do not connect appliances or devices which would overload the UPS system e g laser printers to the UPS output sockets e Place cables in such a way that no one can step on or trip over them e Do not connect domestic appliances such as hair dryers to UPS output sockets e The UPS can be operated by any individuals with no previous experience e Connect the UPS system only to an earthed shockproof outlet which must be easily accessible and close to the UPS system e Please use only VDE tested CE marked mains cable e g the mains cable of your computer to connect the UPS system to the building wiring outlet shockproof outlet e Please use only VDE tested CE marked power cables to connect the loads to the UPS system e When installing the equipment it should ensure that the sum of the leakage current of the UPS and the connected devices does not exceed 3 5mA 1 4 Operation e Do not disconnect the mains cable on the UPS system or the building wiring outlet shockproof socket outlet during operations since this would cancel the protective earthing of the UPS system and of all connected loads e The UPS system features its own internal current source batteries The UPS output sockets or output terminals block may be electrically live even if the UPS system is not connected to the building wiring outlet e In order to fully disconne
15. directamente na rede Retire o excesso de carga ligada UPS e de seguida desligue e reinicie a UPS A UPS desligou se automaticamente devido sobrecarga de sa da da UPS Retire o excesso de carga ligada UPS e de seguida desligue e reinicie a UPS A UPS desligou se automaticamente devido a um curto circuito na sa da da UPS Verifique os cabos e se os dispositivos conectados sa da da UPS est o em curto circuito PHASAM Seguridad y armon a ININTERRUMPIDA PH 9210 PH 9220 PH 9230 PH 9260 Sistema de Alimenta o Ininterrupta 4 Solu o de problemas Houve uma falha interna do SAO Existem duas causas poss veis O erro indica o c digo 1 2 3 4 11 1 A carga est ligada mas 12 13 e 41 no display LCD eo directamente atrav s da rede utilizando alarme soa continuamente o bypass 2 Nenhuma electricidade fornecida carga Contacte o seu servi o de assist ncia Carregue a bateria durante pelo menos cinco horas e em seguida verifique a capacidade Se o problema persistir contacte o seu servi o de assist ncia e Contacte o seu servi o de assist ncia Bateria danificada e para substituir a bateria O ventilador est bloqueado ou Verifique o ventilador e informe o seu danificado revendedor A bateria n o est completamente O tempo de autonomia inferior ao carregada valor nominal O cone e a advert ncia FR piscam no display LCD e o alarme soa cad
16. modelo 5 Protecci n contra sobretensi n de red fax m dem 6 Slot inteligente de puerto RS 232 SNMP o USB opcional 7 Terminales de salida 8 Disyuntor de salida 2 2 Configuraci n del SAI Paso 1 Conexi n de entrada al SAI e Conecte el SAI nicamente a una toma de dos polos tres cables con toma a tierra Evite el uso de cables de extensi n e Para los modelos de 208 220 230 240VAC el cable se suministra con el SAI Nota Para los modelos de baja tensi n Compruebe si el panel LCD se ilumina o no o si indica la falta de conexi n Se ilumina cuando el SAI est conectado a una toma no apropiada Consulte el servicio asistencia Paso 2 Conexi n de salida del SAI e Las tomas de salida son de dos tipos tomas de corriente generales y enchufes programables Conecte las cargas no cr ticas a las salidas programables y los dispositivos cr ticos a las tomas generales En caso de fallo el ctrico puede programar el SAl para aumentar el tiempo de autonom a a las cargas cr ticas y reducirlo para las cargas no cr ticas e Para los SAI 6K siga los pasos abajo detallados para acceder a la configuraci n de los terminales de entrada y salida a Quitar la tapita del bloque de terminales en la parte trasera del SAI b Se recomienda el uso de cableado tipo AWG14 o 2 1mm2 c Al concluir las conexiones compruebe que los cables est n bien sujetos d Vuelva a colocar la tapita del bloque de terminales PH 9210 PH 9220 PH 9230
17. ncia Gama sincronizada 47 53 Hz o 57 63 Hz Gama Frequ ncia Modo bateria 50 Hz 0 25 Hz o 60Hz 0 3 Hz 100 110 aviso acustico 110 130 UPS desliga se em 30 segundos em modo de bateria ou muda a modo Sobrecarga bypass quando ha rede el ctrica normal gt 130 UPS desliga se de imediato em modo de bateria ou muda a modo bypass quando ha rede el ctrica normal Gama de pico actual 3 1 3 THD carga linear 4 THD carga linear 6 THD nao linear 7 THD carga nao linear Tempo Modo AC a bateria Zero transfer ncia Inverter a Bypass 4 ms Tipico Distor o harmonica Forma de onda Modo bateria Sinusoidal pura Modo AC 90 85 Tipo bateria pelo So lodo ld 8 horas para carregar 90 da capacidade T pico 1 0 A max moro Medidas PXAXA pe Humidade relativa sem condensa o 20 90 RH 0 40 C 20 90 RH 0 40 C N vel de ru do lt 45dBA O 1 metro lt 55dBA 1 metro Smart RS 232 ou USB Suporta Windows 98 2000 2003 XP Vista 2008 7 Linux Unix e MAC SNMP Opcional Gestao de energia atraves do SNMP e via web browser Reduzir a capacidade da UPS a 60 em opera o de um conversor de frequ ncia e 80 quando a tens o de sa da fixado em 208VA 12 V 10 AH Modelo Standard O PH 9210 PH 9220 PH 9230 PH 9260 PHASAI Sistema de Alimenta o Ininterrupta ININTERRUMPIDA TABLE OF CONTENTS ER 1 Importa
18. NTERRUMPIDA Sistema de Alimenta o Ininterrupta 3 Opera es 3 5 Configura o da UPS Par metro 1 H tr s par metros ajust veis da UPS Par metro 1 As op es de programa 888 888 H 9 programas para configurar Veja a tabela Os par metros 2 e 3 s o as defini es ou valores estabelecidos para cada programa Par metro 2 Par metro 3 01 Ajuste da tens o de sa da Tens o de sa da Par metro 3 Para os modelos 208 220 230 240 VAC pode se escolher a tensao de sa da seguinte 208 a tens o de sa da 208Vac 220 a tens o de sa da s o 220Vac 230 a tens o de sa da s o 230Vac 240 a tens o de sa da s o 240Vac Par metros 2 e 3 Activa ou desactiva o modo Converter poss vel eleger entre essas duas op es CF ENA modo Converter activado DIS CF modo Converter desactivado Par metros 2 e 3 configurar frequ ncia de sa da g J Pode se configurar a frequ ncia inicial no modo bateria BAT 50 Frequ ncia de sa da 50Hz r mr o A L E SOU a BAT 60 Frequ ncia de sa da 60Hz Se estiver no modo Converter pode se eleger entre as seguintes frequ ncias de sa da CF 50 Frequ ncia de sa da 50Hz CF 60 Frequ ncia de sa da 60Hz O PH 9210 PH 9220 PH 9230 PH 9260 PHASAM Seguridad y armon a Sistema de Alimentac o Ininterrupta ININTERRUMPIDA 3 Opera es E PT 04 ECO activado desactivado Par metro 3 Activa ou desactiva a fun o ECO
19. PH 9260 Uninterruptable Power Supply IA 3 Operations ZA Indicates the Inverter circuit is working Indicates the output is working Indicates the Battery level by 0 25 26 50 51 75 and 76 100 BATT FAULT FAULT Indicates the battery is fault LOW BATT LOW BATT BATT al Indicates low battery level and low battery voltage Vac E E 5 E Vde Indicates the input voltage or frequency or battery voltage fire ics He Vac Input voltage Vdc battery voltage Hz input frequency 3 3 Audible Alarm Dto Coissin 3 4 LCD display wordings index Abbreviation Display contet Menino Dom o EMO mb Dos T A o e eso A PH 9210 PH 9220 PH 9230 PH 9260 ININTERRUPTA Uninterruptible Power Supply 3 Operations 3 5 UPS Setting Parameter 1 888 888 Parameter 2 Parameter 3 01 Output voltage setting There are three parameters to set up the UPS Parameter 1 It s for program alternatives There are 9 programs to set up Refer to the table Parameter 2 and parameter 3 are the setting options or values for each program Parameter 3 Output voltage For 208 220 230 240 VAC models you may choose the following output voltage 208 present output voltage is 208Vac 220 present output voltage is 220Vac 230 present output voltage is 230Vac 240 present output voltage is 240Vac 02 Frequency Converter enable disable Parameter 2 amp 3 Enable or disable con
20. Range Frequency Range Batt Mode 50 Hz 0 25 Hz or 60Hz 0 3 Hz 100 110 audible warning 110 130 UPS shuts down in 30 seconds at battery mode or transfers to bypass mode when the utility is normal 47 53 Hz o 57 63 Hz Overload gt 130 UPS shuts down immediately at battery mode or transfer to bypass mode when the utility is normal Current Crest Ratio 3 1 Harmonic Distortion SU nanda 4 THD linear load 6 THD nonlinear load 7 THD nonlinear load Tempo AC Mode to Batt Mode Zero trasfer Inverter to Bypass 4 ms Typical Pure Sinewave Waveform Batt Mode AC Mode 90 Battery Mode 85 Battery Type 12V 7 AH 12V 9AH 12V 9AH Numbers As 48 q S 6 Recharge Time 8 hours recover to 90 capacity Typical Charging Current 1 0 A max Charging Voltage 41 0 VDC 1 52 0 VDC 1 82 1 VDC 1 109 4 VDC 1 ower enon E Net Weight kg Operation Humidity non condensing 20 90 RH 0 40 C 20 90 RH 0 40 C lt 45dBA 1 meter lt 55dBA 1 meter Smart RS 232 or USB Supports Windows 98 2000 2003 XP Vista 2008 7 Linux Unix and MAC Optional SNMP Power management from SNMP manager and web browser Derate capacity to 60 of capacity in Frequency converter mode and to 80 when the output voltage is adjusted to 208VAC 12 V 10 AH Standard Model G PH 9210 PH 9220 PH 9230 PH 9260 PHASAM Uninterruptable Power Sup
21. a segundo O PH 9210 PH 9220 PH 9230 PH 9260 PHASAM Seguridad y armon a Sistema de Alimentac o Ininterrupta ININTERRUMPIDA 5 Armazenamento e manuten o Interven o A UPS cont m partes n o reutiliz veis A bateria tem uma vida de 3 a 5 anos a 25 C de temperatura ambiente Quando necessitar de substituir a bateria por favor contacte o Servi o de Assist ncia Armazenamento Se poss vel e por seguran a antes de armazenar a bateria carregue a por 5 horas Mantenha a UPS protegida e vertical num local seco e fresco Durante o armazenamento recarregue a bateria de acordo com a tabela seguinte Temperatura armazenamento Frequ ncia de recarregamento Dura o do carregamento PHASAM PH 9210 PH 9220 PH 9230 PH 9260 ININTERRUMPIDA Sistema de Alimenta o Ininterrupta 6 Especifica es MODELO pHo Prozo PHo20 PHozso CAPACIDADE 1000 VA 800W 2000 VA 1600 W 3000 VA 2400 W 6000 VA 4200 W Tens gtransteiencia bae 160VAC 140VAC 120VACA10VAC 5 base em da carga 100 80 80 70 70 60 60 0 Gama de tensao Tens o voltagem baixo 175 VAC 5 ou 85 VAC 5 Tens o transfer ncia alto 300 VAC 5 ou 150 VAC 5 Tens o voltagem alto 290 VAC 5 ou 145 VAC 5 40Hz 70 Hz Factor de Pot ncia 0 99 220 230 VAC ou 110 120 VAC 208 220 230 240VAC Regula o Tens o AC Modo bateria 3 ia Gama Frequ
22. ada segundo O erro indica o c digo 43 o cone pisca no display LCD e o alarme soa continuamente O erro indica o c digo 14 o cone pisca no display LCD e o alarme soa continuamente 4 Solu o de problemas Se o aparelho n o est a funcionar correctamente por favor tente resolver o problema usando a tabela abaixo A entrada de alimenta o AC n o est bem conectada Verifique se o cabo de alimenta o est conectado rede A entrada de AC de alimenta o est ligada sa da da UPS Conecte o cabo de alimenta o entrada AC da UPS Ajuste o encerramento do circuito A fun o EPO est activada para desactivar o EPO Os cabos de linha e neutro da entrada da UPS est o invertidos Rode a tomada 180 e ligue a UPS As baterias internas ou externas n o est o bem conectadas Verifique se todas as baterias est o correctamente conectadas A tens o da bateria muito baixa ou falha do carregador Contacte o seu servi o de assist ncia A tens o da bateria muito baixa ou falha do carregador Contacte o seu servi o de assist ncia A UPS est sobrecarregada ce o excesso de carga ligada a A UPS esta sobrecarregada Os dispositivos conectados a UPS sao alimentados directamente da rede atraves do bypass Retire o excesso de carga ligada a UPS Ap s sobrecarga repetida a UPS est bloqueada no modo bypass Os dispositivos ligados UPS alimentam se
23. ct the UPS system first press the OFF Enter button to disconnect the mains e Prevent no fluids or other foreign objects from inside of the UPS system 1 5 Maintenance service and faults e The UPS system operates with hazardous voltages Repairs may be carried out only by qualified maintenance personnel e Caution risk of electric shock Even after the unit is disconnected from the mains building wiring outlet components inside the UPS system are still connected to the battery and electrically live and dangerous e Before carrying out any kind of service and or maintenance disconnect the batteries and verify that no current is present and no hazardous voltage exists in the terminals of high capability capacitor such as BUS capacitors e Only persons are adequately familiar with batteries and with the required precautionary measures may replace batteries and supervise operations Unauthorized persons must be kept well away from the batteries e Caution risk of electric shock The battery circuit is not isolated from the input voltage Hazardous voltages may occur between the battery terminals and the ground Before touching please verify that no voltage is present e Batteries may cause electric shock and have a high short circuit current Please take the precautionary measures specified below and any other measures necessary when working with batteries gt remove wristwatches rings and other metal objects use only tools with insulat
24. e elegir entre las siguientes frecuencias de salida CF 50 Frecuencia de salida a 50Hz CF 60 Frecuencia de salida a 60Hz PH 9210 PH 9220 PH 9230 PH 9260 PHASAN Sistema de Alimentaci n Ininterrumpida ININTERRUMPIDA 3 Operaciones 04 ECO habilitado desactivado Par metro 3 Activa o desactiva la funci n de la ECO Puede elegir entre las siguientes dos opciones ENA Modo ECO activado DIS Modo ECO desactivado Par metros 2 y 3 Ajuste los l mites aceptables de alta y baja tensi n en modo ECO pulsando Down key o Up key HLS Alta p rdida de tensi n en modo ECO en el par metro 2 Para modelos 208 220 230 240 Vac el rango de ajuste en el par metro 3 es 7V a 24V la tensi n nominal LLS Baja p rdia de tensi n en modo ECO en el par metro 2 Para modelos 208 220 230 240 Vac el rango de ajuste en el par metro 3 es de 7V a 24V voltaje nominal Par metro 3 Activar o desactivar la funci n del bypass Puede elegir entre las siguientes dos opciones ENA Bypass activado DIS Bypass desactivado Par metros 2 y 3 Ajuste los l mites aceptables de alto y bajo voltaje para funcionar en modo de bypass pulsando las teclas Down key o Up key HLS Bypass l mite de alta tensi n Modelos 208 220 230 240 VAC 230 264 El l mite de alta tensi n en el par metro 3 es de 230Vac a 264Vac LLS By pass l mite de baja tensi n Modelos 208 220 230 240 VAC 170 220 el l mite de baja tensi n en
25. ed grips and handles e When changing batteries install the same number and same type of batteries e Do not attempt to dispose of batteries by burning them This could cause battery explosion e Do not open or destroy batteries Escaping electrolyte can cause injury to the skin and eyes It may be toxic e Please replace the fuse only with the same type and amperage in order to avoid fire hazards e Do not dismantle the UPS system NOTE Before installation please inspect the unit Be sure that nothing inside the package is damaged Please keep the original package in a safe place for future use PH 9210 PH 9220 PH 9230 PH 9260 PHASAN Uninterruptable Power Supply ININTERRUPTA Installation and setup 2 1 Rear panel view PH 9210 1K PH 9220 2K PH 9230 3K PH 9260 6K 1 Output receptacles 2 AC input 3 Input circuit breaker 4 External battery connection depends on the model 5 Modem Phone line Network surge protection 6 Intelligent slot with RS 232 port optional USB or SNMP 7 Output terminals 8 Output circuit breaker 2 2 Setup the UPS Step 1 UPS input connection e Plug the UPS into a two pole three wire grounded receptacle only Avoid using extension cords e For 208 220 230 240VAC models The power cord is supplied in the UPS package Note For Low voltage models Check if the site wiring fault indicator lights up in LCD panel It will be illuminated when the UPS is plugged into a
26. either SNMP or AS400 card in the UPS it will provide advanced communication and monitoring options Note USB port and RS 232 port can t work at the same time Step 4 Network connection varies depending on the model Network Fax Phone surge ports n oao Step 5 Disable and enable EPO function varies depending on the model Keep the pin 1 and pin 2 closed for UPS normal operation To activate EPO function cut the wire between pin 1 and pin 2 It s in closed status for UPS normal operation Step 6 Turn on the UPS Press the ON Mute button on the front panel for two seconds to power on the UPS Note The battery charges fully during the first five hours of normal operation Do not expect full battery run capability during this initial charge period Step 7 Install software For optimal computer system protection install UPS monitoring software to fully configure UPS shutdown You may insert provided CD into CD ROM to install the monitoring software If not please follow steps below to download and install monitoring software from the internet 1 Go to the website http www phasak com descargas 2 Click ViewPower software icon and then choose your required OS to download the software 3 Follow the on screen instructions to install the software 4 When your computer restarts the monitoring software will appear as an orange plug icon located in the system tray near the clock Step 8 External battery connection Fo
27. el par metro 3 es de 170Vac a 220Vac PHASAM PH 9210 PH 9220 PH 9230 PH 9260 ININTERRUMPIDA Sistema de AN Ininterrumpida 3 Operaciones 08 Salidas programables activadas desactivadas Parametro 3 Salidas programables activadas o desactivadas ENA Salidas programadas activadas DIS Salida previstas son desactivadas Par metro 3 Fija los l mites del tiempo de autonom a para las tomas programables 0 999 ajusta el tiempo de autonom a durante el modo bater a de O a 999 minutos para las salidas programables conectadas a dispositivos no cr ticos 00 Ajustes de salida PH 9210 PH 9220 PH 9230 PH 9260 PHASAN Sistema de Alimentaci n Ininterrumpida ININTERRUMPIDA 3 Operaciones 3 6 Descripci n del modo operativo Cuando el voltaje de entrada est dentro del rango aceptable el SAI proporcionar una corriente alterna CA Modo Online ae eee l de salida limpia y estable Al mismo tiempo el SAI carga la bater a en modo online A Modo de ahorro energ a j ne j Cuando el voltaje de entrada est dentro del rango 3 LU Modo ECO l A aceptable el SAl funciona en bypass sacando el mismo voltaje de entrada para ahorrar energ a 19 E 8 Fi la Cuando la frecuencia de entrada esta entre 40 Hz y 70 Hz el SAI puede ser programado con una frecuencia de salida constante a 50 Hz o 60 Hz En este modo el SAI continua cargando la bateria Cuando la tension de entrada esta fuera de
28. ente de fuga del SAI y del equipo conectado no sea superior a 3 5mA 1 4 Funcionamiento e No desconecte el cable de alimentaci n de SAI de lo contrario se anular la protecci n que la masa de tierra proporciona al SAl y a todas sus cargas e El SAI tiene su propia de fuente de alimentaci n interna bater as En la toma de salida del SAI o terminales de voltaje de salida puede haber tensiones incluso si el SAl no est conectado a la red e Para desconectar completamente el SAI presione el interruptor OFF Enter e Impida la entrada de l quidos u objetos extra os al interior del SAI 1 5 Mantenimiento y reparaci n e El SAI funciona con voltajes peligrosos Cualquier reparaci n debe ser realizada exclusivamente por personal cualificado e Precauci n Riesgo de descarga el ctrica Incluso despu s de desconectarse de la red el cableado interno contin a conectado a la bater a y la tensi n es peligrosa e Antes de realizar cualquier tipo de servicio y o mantenimiento desconecte las bater as verificando que no haya corriente ni exista riesgo de voltaje incluidas las creadas por los condensadores de alta capacidad e S lo las personas habilitadas para tratar con bater as y que lo hagan con las medidas y precauciones necesarias pueden sustituir las bater as y controlar las operaciones e Precauci n Riesgo de descarga el ctrica La bater a no est aislada del circuito de la tensi n de entrada Puede haber voltajes peligro
29. fter repetitive overloads the UPS is Remove excess loads from UPS locked in the Bypass mode Connected output first Then shut down the UPS devices are fed directly by the mains and restart it Fault code is shown as 43 and the The UPS shut down automatically icon is lighting on LCD display because of overload at the UPS output and alarm is continuously sounding Remove excess loads from UPS output and restart it The UPS shut down automatically because short circuit occurs on the Check output wiring and if connected UPS output devices are in short circuit status Fault code is shown as 14 and the icon is lighting on LCD display and alarm is continuously sounding PHASAN PH 9210 PH 9220 PH 9230 PH 9260 ININTERRUPTA Uninterruptible Power Supply 4 Troubleshooting A UPS internal fault has occurred There are two possible results 1 The load is still supplied but directly from AC power via bypass 2 The load is no longer supplied by power Fault code is shown as 1 2 3 4 11 12 13 and 41 on LCD display and alarm is continuously sounding Contact your dealer Charge the batteries for at least 5 hours and then check capacity If the Battery backup time is shorter than problem still persists consult your nominal value dealer Batteries defect Contact your dealer to replace the battery Fan is locked or not working Batteries are not fully charged The icon A and the warning codef A flashing on
30. inel frontal A cada 10 segundos o aparelho emite um alarme Modo Espera Quando a UPS desligada n o tira pot ncia mas tamb m carrega a bateria PHASAM PH 9210 PH 9220 PH 9230 PH 9260 ININTERRUMPIDA Sistema de Alimenta o Ininterrupta 3 Opera es 3 7 C digo de erro causa datalna Neerro icone Causadafalma Wero icone Mo n energia on x Tensdoinversorbaxa 19 x Tens o Entrada ata 02 x Cunosaidaiwersor 14 CJ Tensa Entrada baixa 08 x Tensdobateraata 27 Gu Entrada n o balanceada 04 x Tensfobateriabaxa 26 Qua Erro arranque inversor 11 x Sobre aquecimento a x 3 8 Indicadores de alerta A WN UPS sobrecarregada Soando cada segundo Erro da carga da bateria Soando cada segundo Bypass fora da gama de PH 9210 PH 9220 PH 9230 PH 9260 Hat Sistema de Alimenta o Ininterrupta ININTERRUMPIDA Sem indicagao nem alarme mesmo se a energia esta normal O cone e o c digo indica EP piscam no display LCD e o alarme soa cada segundo O cone A e Y piscam no display LCD e o alarme soa cada segundo O cone A e E piscam no display LCD e o alarme soa cada segundo O erro indica o c digo 27 o cone pisca no display LCD e o alarme soa continuamente O erro indica o c digo 28 o cone pisca no display LCD e o alarme soa continuamente O cone e piscam no display LCD e o alarme soa duas vezes c
31. ivar a UPS em modo bateria Ao pressionar este bot o o aparelho colocado em modo de espera se houver alimenta o ou muda a modo bypass se o bypass Bot o OFF Enter permitir e Bot o de confirma o de selec o pressione este bot o para confirmar um ajuste do modo de configura o da UPS e Mudan a LCD Mensagem Clique neste bot o para alterar a mensagem do LCD para a tens o de entrada frequ ncia de entrada tens o de bateria tens o de sa da e frequ ncia sa da O LCD retorna visualiza o inicial ap s uma pausa de 10 Bot o Select ronan a l P e Modo configura o Pressione o bot o por 5 segundos para entrar no modo de configura o com a UPS em modo de espera ou bypass e Up key pressione este bot o para seleccionar a pr xima op o de configura o da UPS e Muda para modo bypass Quando a alimenta o normal no modo AC pressione Bot es ON Mute simultaneamente os bot es ON Mute e Select por 5 segundos e a UPS mudar para Select modo bypass Esta fun o n o poss vel quando a tens o de entrada est fora da faixa aceit vel PHASAM PH 9210 PH 9220 PH 9230 PH 9260 ININTERRUMPIDA Sistema de Alimenta o Ininterrupta 3 Opera es 3 2 Painel LCD Informa o Informa o de autonomia de erro Informa o de alarme Informa o tens o de entrada e bateria Informa o tens o de sa da e bateria Informa o da bateria gt Informa o
32. l rango aceptable o hay un fallo de alimentaci n el SAI emite un sonido de Mono Datena alarma cada 4 segundos El SAI se mantendr activo hasta que termina la autonom a de la bater a Cuando el voltaje de entrada es aceptable pero el SAI est sobrecargado el SAI entrar en modo bypass o se puede Mono Sy Pass configurar este modo bypass desde el panel frontal Cada 10 segundos el SAI emite una alarma Modo Espera Cuando el SAI se apaga no alimenta la salida pero tambi n carga la bateria Modo de conversi n de frecuencia O PHASAN PH 9210 PH 9220 PH 9230 PH 9260 ININTERRUMPIDA Sistema de Alimentaci n Ininterrumpida 3 Operaciones 3 7 C digo de fallo causa deifallo Neerror icono Causadelfalio Neerror loono Nose enciende o x Vokimvererbajo 13 x Vor Entrada ato 02 x Conoinverersalda 14 Ge Vo Entrada bajo 08 x Votibateriaato 27 m Entrada no balanceada o4 x Vo Bateriabajo 26 mm C Eror arangue inverter 11 x Sobrecalentamiento a x 3 8 Indicadores de advertencia A boo SAI sobrecargado Sonido cada segundo Error de carga de bater a Sonido cada segundo Bypass fuera de rango PH 9210 PH 9220 PH 9230 PH 9260 Hat Sistema de Alimentaci n Ininterrumpida ININTERRUMPIDA Si el SAI no funciona correctamente por favor resuelva utilizando el cuadro siguiente Sin indicaci n ni alarma incluso si la alimentaci
33. le o software de monitoriza o no seu PC para configurar a UPS Insira o CD no CD ROM para instalar o software de controlo Se n o siga estes passos para fazer o download do software da internet 1 Visite o site Web http www phasak com descargas 2 Clique no ViewPower e seleccione o seu sistema operativo OS 3 Siga as instru es no ecr para instalar o software 4 Quando reiniciar o PC o software apresentado como um cone laranja no canto inferior do ecr no tabuleiro do sistema perto do rel gio Passo 8 Conex o da bateria externa Para a conex o de bateria externa veja a figura seguinte PH 9210 PH 9220 PH 9230 PH 9260 PHASAN Sistema de Alimentac o Ininterrupta ININTERRUMPIDA 3 Opera es 3 1 Bot es de funcionamento Bot o Fun o e Liga a UPS Mantenha pressionada a tecla de ON Mute por 2 segundos para ligar a UPS e Para silenciar o alarme quando a UPS entra em modo de bateria pressione por pelo menos 5 segundos para activar ou desactivar o sistema de alarme N o se Bot o ON Mute aplica em caso de erro ou avisos g e Down key pressionar este bot o para mostrar a selec o pr via no modo de configura o da UPS e Mudan a no modo de auto teste simultaneamente pressione o bot o ON Mute por 5 segundos para entrar no auto teste enquanto no modo AC modo ECO ou conversor de modo e Desligar a UPS Mantenha pressionada a tecla de ON Mute por 2 segundos para desact
34. llow below chart to make external battery connection O PH 9210 PH 9220 PH 9230 PH 9260 PHASAIZ Uninterruptable Power Supply ININTERRUPTA 3 Operations 3 1 Button operation e Turn on the UPS Press and hold ON Mute button for at least 2 seconds to turn on the UPS e Mute the alarm When the UPS is on battery mode press and hold this button for at least 5 seconds to disable or enable the alarm system But it s not applied to the situations when warnings or errors occur e Down key Press this button to display previous selection in UPS setting mode e Switch to UPS self test mode Press ON Mute buttons simultaneously for 5 seconds to enter UPS self testing while in AC mode ECO mode or converter mode ON Mute Button e Turn off the UPS Press and hold this button at least 2 seconds to turn off the UPS in battery mode UPS will be in standby mode under power normal or transfer to OFF Enter Button Bypass mode if the Bypass enable setting by pressing this button e Confirm selection key Press this button to confirm selection in UPS setting mode e Switch LCD message Press this button to change the LCD message for input voltage input frequency battery voltage output voltage and output frequency It will return back to default display when pausing for 10 seconds e Setting mode Press and hold this button for 5 seconds to enter UPS setting mode when UPS is in standby mode or bypass mode e Up key Press this button to di
35. low The AC input power is not connected Check if input power cord firmly well connected to the mains No indication and alarm even though the mains is normal The AC input is connected to the UPS Plug AC input power cord to AC input output correctly The icon and the warning E code flashing on LCD display and EPO function is activated alarm is sounding every second Set the circuit in closed position to disable EPO function The icon A and flashing on LCD display and alarm is sounding every second Line and neutral conductors of UPS Rotate mains power socket by 180 input are reversed and then connect to UPS system The icon and 8 flashing on LCD display and alarm is sounding every second The external or internal battery is Check if all batteries are connected incorrectly connected well Fault code is shown as 27 and the icon is lighting on LCD display and alarm is continuously sounding Battery voltage is too high or the charger is fault Contact your dealer Ruca o Battery voltage is too low or the charger icon is lighting on LCD display na g g Contact your dealer and alarm is continuously sounding l UPS is overload Remove excess loads from UPS output UPS is overloaded Devices connected to the UPS are fed directly by the The cond and is flashing electrical network via the Bypass on LCD display and alarm is sounding twice every second Remove excess loads from UPS output A
36. n improperly wired utility power outlet Refer to Troubleshooting section Step 2 UPS output connection e For socket type outputs there two kinds of outputs programmable outlets and general outlets Please connect non critical devices to the programmable outlets and critical devices to the general outlets During power failure you may extend the backup time to critical devices by setting shorter backup time for non critical devices e For terminal type input or outputs on the 6K UPS please follow below steps for the wiring configuration a Remove the small cover of the terminal block b Suggest using AWG14 or 2 1mm2 power cords c Upon completion of the wiring configuration please check whether the wires are securely affixed d Put the small cover back to the rear panel PH 9210 PH 9220 PH 9230 PH 9260 ININTERRUPTA Uninterruptible Power Supply Seguran a e harmonia 2 Installation and setup Step 3 Communication connection varies depending on the model Communication port USB Port RS 232 Port Intelligent Slot f oo eh O To allow for unattended UPS shutdown start up and status monitoring connect the communication cable one end to the USB RS 232 port and the other to the communication port of your PC With the monitoring software installed you can schedule UPS shutdown start up and monitor UPS status through PC The UPS is equipped with intelligent slot perfect for either SNMP or AS400 card When installing
37. nt Safety Warning A 4 1 1 Transportation 34 1 2 Preparation 34 1 3 Installation 34 1 4 Operations 34 1 5 Maintenance service and faults 34 2 Installation and setup 35 2 1 Rear panel view 35 2 2 Setup the UPS 35 3 Operations 37 3 1 Button operation 37 3 2 LCD Panel 68 3 3 Audible Alarm 39 3 4 LCD display wordings index 39 3 5 UPS Setting 40 3 6 Operating Mode Description 43 3 Faults Reference Code 44 3 8 Warning indicator 44 4 Troubleshooting 45 5 Storage and Maintenance 47 6 Specifications CB PH 9210 PH 9220 PH 9230 PH 9260 ININTERRUMPIDA Uninterruptible Power Supply Seguridad y armon 1 Important Safety Warning Please comply with all warnings and operating instructions in this manual strictly Save this manual properly and read carefully the following instructions before installing the unit Do not operate this unit before reading through all safety information and operating instructions carefully 1 1 Transportation e Please transport the UPS system only in the original package to protect against shock and impact 1 2 Preparation e Condensation may occur if the UPS system is moved directly from cold to warm environment The UPS system must be absolutely dry before being installed Please allow at least two hours for the UPS system to acclimate the environment e Do not install the UPS system near water or in moist environments e Do not install the UPS system where it would be exposed to
38. ntrada frecuencia o tensi n de la bater a Vac tensi n de entrada E e HE Vdc tension bater a Hz frecuencia de entrada 3 3 Alarma ac stica 3 4 Indicaci n del display LCD EMO EAR Habitat OS AIG Deshabilitado E ESE Escape 3 PH 9210 PH 9220 PH 9230 PH 9260 ININTERRUMPIDA Sistema de Alimentaci n Ininterrumpida 3 Operaciones 3 5 Configuraci n del SAI Par metro 1 Hay tres par metros de ajuste del SAI Parametro 1 opciones de programas 888 888 Hay 9 programas a configurar Consulte la siguiente tabla El Par metro 2 y el Par metro 3 son las opciones de configuraci n o valores establecidos para cada programa Par metro 2 Par metro 3 01 Ajuste de la tensi n de salida Voltaje de salida Par metro 3 Para los modelos 208 220 230 240 VAC se puede elegir el voltaje de salida siguiente 208 la tensi n de salida es de 208Vac 220 la tensi n de salida es de 220Vac 230 la tensi n de salida es de 230Vac 240 la tensi n de salida es de 240Vac Par metros 2 y 3 Activa o desactiva el modo convertidor Es posible elegir entre las dos opciones siguientes CF ENA modo convertidor activado DIS CF modo de convertidor desactivado g J ZA Par metro 2 y 3 configurar frecuencia de salida Puede configurar la frecuencia inicial en modo bater a LE E 5 ni BAT 50 Frecuencia de salida a 50Hz L at LLLI ss BAT 60 Frecuencia de salida a 60Hz Si esta en modo convertidor pued
39. o tempo de autonomia das tomadas program veis 0 999 ajusta o tempo de autonomia durante o modo bateria de O a 999 minutos para as sa das program veis conectadas aos dispositivos n o cr ticos 00 Ajustes de sa da O PH 9210 PH 9220 PH 9230 PH 9260 PHASAI Sistema de Alimenta o Ininterrupta ININTERRUMPIDA 3 Opera es 3 6 Descri o do modo de opera o Quando a tens o de entrada est dentro do intervalo aceit vel a UPS fornece uma corrente alternada CA Modo Online cd i sa da limpa e est vel Ao mesmo tempo a UPS carrega a bateria em modo online E Modo poupan a de energia j Quando a tens o de entrada est dentro do intervalo 3 Li Modo ECO 7 i OUTPUT aceit vel a UPS opera em bypass tirando a mesma tens o de entrada para economizar energia 19 E a s E Quando a frequ ncia de entrada est entre 40 Hz e 70 Hz a Modo de convers o de UPS pode ser programada com uma frequ ncia de sa da frequ ncia constante de 50 Hz ou 60 Hz Neste modo a UPS continua a carregar a bateria Quando a tens o de entrada est fora do intervalo aceit vel ou se houver uma falha de energia o aparelho emite um Modo bateria 7 alarme cada 4 segundos A UPS permanecer activa at ao final da vida til da bateria Quando a tens o de entrada aceit vel mas a UPS est Mode Bu ass sobrecarregada entra em modo bypass ou esse modo yP bypass pode ser definido a partir do pa
40. ply ININTERRUPTA NOTAS NOTAS NOTES a PH 9210 PH 9220 PH 9230 PH 9260 uran a e harmonia Seg ININTERRUPTA PHASAM Seguridad y armonia ININTERRUMPIDA O 2013 PHASAK
41. r la unidad No utilice este aparato sin antes leer con atencion toda la informacion sobre seguridad e instrucciones 1 1 Transporte e Por favor transporte el SAI en la caja original para protegerlo de los posibles choques y golpes 1 2 Preparacion e Cuando el SAI pasa de un ambiente caliente a otro fr o se puede crear condensaci n El equipo debe estar completamente seco antes de su instalacion Por favor deje el SAI por lo menos dos horas para climatizarlo e No instale el SAI cerca del agua o en ambientes h medos e No instale el SAI expuesto a la luz solar directa o cerca de fuentes de calor e No bloquee los orificios de ventilaci n del SAI 1 3 Instalaci n e No conecte la toma de salida del SAI a dispositivos dispositivos que puedan sobrecargarlos por ejemplo impresoras l ser e Coloque los cables de modo que no se puedan pisar o tropezar con ellos e No conecte a la toma del SAI aparatos como secadores de pelo e El SAl puede ser manejado por cualquier persona incluso sin experiencia e Conecte el SAI nicamente a un enchufe con toma de tierra que sea f cilmente accesible y cercano al SAI de manera que no se pisotee el cable e Por favor use s lo cables de alimentaci n con homologaci n VDE y CE para conectar el SAl a la toma de red con toma de tierra e Use s lo cables de alimentaci n con homologaci n VDE y CE para conectar las cargas al SAI e Al instalar el SAI debe asegurarse de que la suma de la corri
42. recarga 8 horas para cargar al 90 de capacidad T pico Corriente de carga 1 0 A max Volt de carga 41 0 VDC 1 52 0 VDC 1 82 1 VDC 1 109 4 VDC 1 Caja Medidas Pr X An X Al Torre Peso neto kg Humedad relativa sin condensa 20 90 RH 0 40 C 20 90 RH 0 40 C Nivel de ruido lt 45dBA 1 metro lt 55dBA O 1 metro Smart RS 232 o USB Soporta Windows 98 2000 2003 XP Vista 2008 7 Linux Unix and MAC SNMP Opcional Power management from SNMP manager and web browser Reducir la capacidad del SAI al 60 en la explotaci n de un convertidor de frecuencia y el 80 cuando el voltaje de salida se ha fijado en 208VAC 12 V 10 AH Modelo Standard O PH 9210 PH 9220 PH 9230 PH 9260 PHASAI Sistema de Alimentaci n Ininterrumpida ININTERRUMPIDA INDICE 1 Aviso importante de seguranca 48 1 1 Transporte 18 1 2 Prepara o 18 1 3 Instala o 18 1 4 Funcionamento 18 1 5 Manuten o e repara o 18 2 Instala o e configura o 19 2 1 Vista painel traseiro 19 2 2 Configura o da UPS 19 3 Opera es 21 3 1 Bot es de funcionamento 21 3 2 Painel LCD 22 3 3 Alarme ac stico 23 3 4 Indica o do display LCD 23 3 5 Configura o da UPS 24 3 6 Descri o do modo operativo 21 3 C digo de erro 28 3 8 Indicadores de alerta 28 4 Solu o de problemas 29 5 Armazenamento e manuten o 31 6 Especifica es 32 PH 9210 PH 9220 PH 9230
43. ry under this mode When the input voltage is beyond the acceptable range or Battery mode power failure and alarm is sounding every 4 second UPS will backup power from battery When input voltage is within acceptable range but UPS is Bypass mode overload UPS will enter bypass mode or bypass mode can be set by front panel Alarm is sounding every 10 second UPS is powered off and no output supply power but still can rane made charge batteries Frequency Converter mode O PHASAM PH 9210 PH 9220 PH 9230 PH 9260 ININTERRUPTA Uninterruptible Power Supply 3 Operations 3 7 Faults Reference Code 7 Fautevem Faultcode leon Faultevent Faultcode Icon Faltas O x imverervotagelom 18 x Bus over 02 x imvereronpushon 4 O Bus under oo x Battery votage toorigh 27 mm Bus unbalance o4 x Battery voltage too low 28 mmn inventer sofestartfal 11 x Overtemperature a xX 3 8 Warning indicator Low Battery N Sounding every second Battery is not connected N Sounding every second T Over Charge Sounding every second Site wiring fault Sounding every second ve EPO enable Sounding every second Charger failure Sounding every second ae ENE allege Sounding every second PH 9210 PH 9220 PH 9230 PH 9260 Uninterruptable Power Supply IA 4 Troubleshooting If the UPS system does not operate correctly please solve the problem by using the table be
44. sos entre los terminales de la bater a y de la tierra Antes de tocar nada por favor compruebe que no haya tensi n e Las bater as pueden causar descargas el ctricas y cortocircuitos Por favor tome las precauciones abajo detalladas y cualquier otra medida necesaria cuando se trabaja con las bater as gt Eliminar los relojes anillos y otros objetos met licos gt Utilice s lo herramientas con asas y mangos aislados e Cuando cambie las bater as instale la misma cantidad y el mismo tipo de bater as e No intente tirar a la basura o quemar las bater as porque podr an explotar e No abra o destruya las bater as El electrolito que se desprende puede da ar la piel y los ojos La bater a es t xica e Por favor reemplace el fusible nicamente por otro del mismo tipo y amperaje para evitar riesgo de incendio e No desmonte el SAI bajo ning n concepto NOTA Antes de la instalaci n por favor compruebe la unidad Aseg rese de que nada en el interior del embalaje est da ado Por favor mantenga el embalaje original en un lugar seguro para un futuro uso O PH 9210 PH 9220 PH 9230 PH 9260 PHASAM Seguridad y armon a Sistema de Alimentaci n Ininterrumpida ININTERRUMPIDA 2 Instalaci n y configuraci n 2 1 Vista panel posterior PH 9210 1K PH 9220 2K PH 9230 3K PH 9260 6K 1 Z calos de salida 2 Entrada de red CA 3 Disyuntor 4 Conector de bater as externas var a en funci n del
45. splay next selection in UPS setting mode Select Button ON Mute Select e Switch to bypass mode When the main power is normal press ON Mute and Select Button buttons simultaneously for 5 seconds Then UPS will enter to bypass mode This action will be ineffective when the input voltage is out of acceptable range O PHASAM PH 9210 PH 9220 PH 9230 PH 9260 ININTERRUPTA Uninterruptible Power Supply 3 Operations 3 2 LCD Panel Backup Fault Time Info Info Mute Input amp Battery Voltage Info Output amp Battery Voltage Info Battery wal Info NSS E Ea eco y am zg A IB gt Load Info w E y Mode Programmable Operation Info Outlet Info Indicates the backup time in pie chart 4 Indicates the backup time in numbers S A H hours M minute S second lt lt DA Indicates that the warning and fault occurs g g Indicates the warning and fault codes and the codes are listed in details in 3 5 A section Indicates that the UPS alarm is disabled E 5 g vde Indicates the output voltage frequency or battery voltage OUTPUT Vac output voltage Vdc battery voltage Hz frequency K Indicates the load level by 0 25 26 50 51 75 and 76 100 OVER LOAD Indicates overload SHORT Indicates the load or the UPS output is short circuit Indicates that programmable management outlets are working PH 9210 PH 9220 PH 9230
46. stalar el software Para una protecci n ptima del sistema instale el software de control del SAl en su PC para configurar el apagado del SAI Inserte el CD suministrado en la unidad CD Rom para instalar el software de control Si no siga los siguientes pasos para descargar el software de internet 1 Introducci n de la p gina web http www phasak com descargas 2 Haga clic en ViewPower y elija el sistema operativo OS para transferir el software a su PC 3 Siga las instrucciones en la pantalla del monitor para instalar el software 4 Cuando reinicie su PC ver un icono de color naranja en el rea de notificaciones cerca del reloj de su PC abajo a la derecha Paso 8 Conexi n de la bater a externa Para la conexi n de bater a externa v ase la siguiente figura O PH 9210 PH 9220 PH 9230 PH 9260 PHASAM Seguridad y armon a Sistema de Alimentaci n Ininterrumpida ININTERRUMPIDA 3 Operaciones 3 1 Botones de funcionamiento e Enciende el SAI Mantenga pulsada la tecla ON Mute durante 2 segundos para encender el SAI e Silenciar la alarma Cuando el SAI entra en modo de bater a mantenga pulsada la tecla durante al menos 5 segundos para activar o desactivar el sistema de alarma Bot n ON Mute No es aplicable en caso de error o advertencias e Down key pulse este bot n para mostrar la selecci n anterior en el modo configuraci n del SAI e Cambio a modo de auto prueba pulse simult neamen
47. suministra electricidad a la carga Pongase en contacto con su servicio asistencia Cargar la bater a durante al menos 5 horas y luego comprobar la capacidad Si el problema persiste p ngase en contacto con el servicio de asistencia 5 7 P ngase en contacto con su servicio Bateria danada o j asistencia para sustituir la bater a El voltaje de la bater a es demasiado P ngase en contacto con su servicio alto o el cargador falla asistencia La bater a no est completamente El tiempo de autonom a es m s cargada breve del valor nominal El icono A y el aviso F parpadean en el display LCD y la alarma suena cada segundo PH 9210 PH 9220 PH 9230 PH 9260 PHASAM Seguridad y armon a Sistema de Alimentaci n Ininterrumpida ININTERRUMPIDA 5 Almacenamiento y mantenimiento Intervenci n El SAI contine partes no reutilizables La bater a tiene una vida de 3 5 a os a 25 C de temperatura ambiente Cuando tengan que ser sustituidos por favor p ngase en contacto con su servicio asistencia Almacenamiento Si es posible y por seguridad antes de almacenarla cargue la bater a durante 5 horas Mantenga el SAI protegido y en posici n vertical en un lugar seco y fresco Durante el almacenamiento recargue la bater a de acuerdo con el siguiente cuadro Temperatura almacenaje Duraci n de la carga PHASAM PH 9210 PH 9220 PH 9230 PH 9260 ININTERRUMPIDA Sistema de Alimentaci n Inin
48. te los botones de ON Mute durante 5 segundos para entrar en auto prueba estando en modo AC en modo ECO o modo convertidor e Apagar el SAI Pulse el boton durante 2 segundos para desactivar el SAl en modo bateria Presionando este bot n el SAI se pone en modo de espera estando con z alimentaci n normal o cambia a modo bypass si el bypass lo permite Boton OFF Enter e Bot n de confirmaci n de la selecci n presione este bot n para confirmar un ajuste en el modo configuraci n del SAI e Cambio de mensaje en LCD Pulse este bot n para cambiar el mensaje del LCD para el voltaje de entrada la frecuencia de entrada el voltaje de la bater a el voltaje de salida y la frecuencia de salida El LCD vuelve a la vista por defecto tras una Bot n Select pausa de 10 segundos e Modo de configuraci n Pulse el bot n durante 5 segundos para entrar en modo de ajustes con el SAl en modo espera o bypass e Up key presione este bot n para seleccionar la siguiente opci n de configuraci n de SAI e Cambia a modo bypass Cuando la alimentaci n es normal modo AC pulse Botones simult neamente los botones ON Mute y Select durante 5 segundos y el SAl entrar ON Mute Select en modo bypass Esta funci n no ser posible cuando el voltaje de entrada est fuera un rango aceptable PHASAM Seguridad y armon a PH 9210 PH 9220 PH 9230 PH 9260 ININTERRUMPIDA Sistema de Alimentaci n Ininterrumpida 3 Operaciones 3 2 Panel
49. terrumpida 6 Especificaciones MODELO PH9210 pH9220 pH9230 PH920 CAPACIDAD 1000 VA 800W 2000 VA 1600W 3000 VA 2400 W 6000 VA 4200 W 160VAC 140VAC 120VAC 110VAC 5 o base en carga 100 80 80 70 70 60 60 0 Volt transferencia baja Rango Volt Volt regreso bajo 175 VAC 5 o 85 VAC 5 Volt transferencia alto 300 VAC 5 o 150 VAC 5 Volt regreso alto 290 VAC 5 o 145 VAC 5 40Hz 70 Hz Factor de Potencia 0 99 220 230 VAC o 110 120 VAC 208 220 230 240VAC 3 Volt salida Regulaci n Volt AC Modo bater a Rango frecuencia Rango sincronizado Rango frecuencia Modo bateria 50 Hz 0 25 Hz o 60Hz 0 3 Hz 47 53 Hz o 57 63 Hz 100 110 aviso ac stico 110 130 UPS se apaga en 30 segundos en modo de bater a o cambia a modo Sobrecarga bypass cuando hay red el ctrica normal gt 130 UPS se apaga de inmediato en modo de bater a o cambia a modo bypass cuando hay red el ctrica normal Valor de corriente de cresta 3 1 Distorsi n harm nica a THD carga Inea 4 THD carga lineal 6 THD no lineal 7 THD carga no lineal Tiempo Modo AC a bater a Cero trasfer Inverter a Bypass 4 ms T pico Sinusoidal pura Forma de onda Modo bater a Modo AC 90 Modo bater a 85 Tipo bater a 12 V 7 AH 12 V 9 AH 12 V 9 AH Numero a 48 q eee Tiempo
50. verter mode You may choose the following two options CF ENA converter mode enable CF DIS converter mode disable 03 Output frequency setting E S PH 9210 PH 9220 PH 9230 PH 9260 Uninterruptable Power Supply Parameter 2 amp 3 Output frequency setting You may set the initial frequency on battery mode BAT 50 present output frequency is 50Hz BAT 60 present output frequency is 60Hz If converter mode is enabled you may choose the following output frequency CF 50 present output frequency is 50Hz CF 60 present output frequency is 60Hz PHASAM Seguran a e harmonia ININTERRUPTA 3 Operations 04 ECO enable disable Parameter 3 Enable or disable ECO function You may choose the following two options ENA ECO mode enable DIS ECO mode disable Parameter 2 amp 3 Set the acceptable high voltage point and low voltage point for ECO mode by pressing Down key or Up key HLS High loss voltage in ECO mode in parameter 2 For 208 220 230 240 VAC models the setting range in parameter 3 is from 7V to 24V of the nominal voltage LLS Low loss voltage in ECO mode in parameter 2 For 208 220 230 240 VAC models the setting range in parameter 3 is from 7V to 24V of the nominal voltage Parameter 3 Enable or disable Bypass function You may choose the following two options ENA Bypass enable DIS Bypass disable Parameter 2 amp 3 Set the acceptable high voltage point and acceptable low
51. voltage point for Bypass mode by pressing the Down key or Up key HLS Bypass high voltage point For 208 220 230 240 VAC models 230 264 setting the high voltage point in parameter 3 from 230Vac to 264Vac LLS Bypass low voltage point For 208 220 230 240 VAC models 170 220 setting the low voltage point in parameter 3 from 170Vac to 220Vac O PHASAM PH 9210 PH 9220 PH 9230 PH 9260 ININTERRUPTA Uninterruptible Power Supply 3 Operations 08 Programmable outlets enable disable Parameter 3 Enable or disable programmable outlets ENA Programmable outlets enable DIS Programmable outlets disable Parameter 3 Set up backup time limits for programmable outlets 0 999 setting the backup time limits in minutes from 0 999 for programmable outlets which connect to non critical devices on battery mode 00 Exit setting PH 9210 PH 9220 PH 9230 PH 9260 PHASAN Uninterruptable Power Supply ININTERRUPTA 3 Operations 3 6 Operating Mode Description When the input voltage is within acceptable range UPS will Online mode provide pure and stable AC power to output The UPS will also charge the battery at online mode Energy saving mode ECO mode When the input voltage is within voltage regulation range UPS will bypass voltage to output for energy saving When input frequency is within 40 Hz to 70 Hz the UPS can be set at a constant output frequency 50 Hz or 60 Hz The UPS will still charge batte