Home

VPAP™ Auto

image

Contents

1. RAMP 20min menu 1 warmup SETTLE 20min menu 1 warmup CPAP and S modes VAuto mode shows RAMP setting shows SETTLING setting Figure 3 Patient Menu display with humidifier prior to starting treatment After treatment starts the treatment screen displays see Figure 5 Treatment screens all modes on page 15 Menus with a ResLink and Oximeter If your clinician has recommended that you use a ResLink module and the ResLink and an oximeter are connected to the VPAP Auto then display of SpO oxygen saturation and HR heart rate takes priority If treatment has not commenced the VPAP Auto will display one of the following screens whether a humidifier is connected or not Prior to starting treatment SpO2 98 RAMP 20min 98 SETTLE 20min 98 menu HR 60 menu t HR 60 menu Y HR 60 Max Ramp off Max Ramp set Max Settle set or to non zero value to non zero value Max Settle off Figure 4 Menu display with ResLink and oximeter Accessing the Menus To navigate and make selections within the Patient Menu use the Up Down key to scroll through items within a level the Left key to enter a submenu and to apply an option choice the Right key to navigate out of a menu or submenu and to exit without changing options Oxygen saturation SpO2 The saturation of blood hemoglobin Heart rate HR The number of heartbeats in a 60 second time frame beats per minute Operating Instructions English
2. Compatibilit lectromagn tique Le produit est conforme a toutes les exigences de compatibilit lectromagn tique CEM applicables conform ment CEI60601 1 2 pour les environnements commerciaux r sidentiels et l industrie l g re Pour de plus amples informations voir Guide et d claration du fabricant Emissions et immunit lectromagn tiques page 35 Niveau de bruit VPAP Auto Mode CPAP pression 10 cm H 0 Niveau acoustique pond r A mesur 24 dBA dB pour 20 uPa Incertitude dB pour 20 uPa 2 dBA Les valeurs mesur es ont t d termin es conform ment la proc dure d essai acoustique d crite dans la norme ISO 17510 1 Remarque la somme des valeurs d mission sonore mesur es et l incertitude qui en r sulte repr sentent un plafond pour la fourchette de valeurs susceptibles d tre observ es lors de ces mesures Fran ais a Valeurs d mission sonore deux chiffres d clar es conform ment la norme ISO 4871 Filtre air deux couches de mousse cellules ouvertes de polyester impr gn es de fibres polyester Circuit respiratoire plastique flexible longueur 1 x 6 6 2 m Sortie d air le raccord conique 22 mm de sortie d air est conforme la norme EN 1281 1 Classification CEI 60601 1 Classe double isolation Type CF Remarque le fabricant se r serve le droit de modifier ces caract ristiques sans notification pr alable
3. Strat gie de d pannage Fran ais 31 32 Caract ristiques Performance Pression de fonctionnement 3 20 cm H20 Pression maximale d livr e en cas de d faillance 30 cm H 0 Tol rance pour la mesure de la pression 0 5 cm H 0 4 de la valeur mesur e Tol rance pour la mesure du d bit 0 1 ou 20 de la mesure si cette valeur est sup rieure 0 1 Caract ristiques de pression dynamique Mode VAuto 4 20 cm H50 au masque Pression EPAP Min 4 cm H 0 Pression IPAP Max 20 cm H 0 Aide inspiratoire 0 10 cm H20 Mode S IPAP 5 20 cm H 0 au masque EPAP 3 20 cm H 0 au masque Mode CPAP 4 20 cm H20 au masque Niveau de bruit le niveau de pression acoustique est mesur un niveau lt 30 dBA 10 cm H20 et 3 3 37 1 m conform ment IS017510 Dimensions L x I x H 4 4 x 6 5 x 5 7 112 mm x 164 mm x 145 mm Poids 2 9 lb 1 3 kg Alimentation lectrique Courant 100 240 V 50 60 Hz 40 VA consommation de courant typique lt 100 VA consommation de courant maximale Boitier thermoplastique ignifug Conditions ambiantes Temp rature de fonctionnement 41 F 95 F 5 C a 35 C umidit de fonctionnement 10 95 sans condensation Temp rature de stockage et de transport 4 F 140 F 20 C 60 C umidit de stockage et de transport 10 95 sans condensation Altitude de fonctionnement niveau de la mer 8500
4. Ajuste de mascarilla El generador de aire suministrar el tratamiento m s efectivo cuando la mascarilla est bien puesta y resulta c moda El tratamiento puede verse afectado por las fugas por lo que es importante eliminar todas las fugas que pudieran surgir Si tiene problemas al tratar de conseguir que la mascarilla est c modamente ajustada p ngase en contacto con su cl nica del sue o o con el proveedor de su equipo Es posible que le convenga usar una mascarilla de otro tama o Tambi n puede usar la funci n Ajuste de mascarilla para que le ayude a conseguir un ajuste adecuado Ver Uso de la funci n Ajuste de mascarilla en la p gina 14 Antes de ponerse la mascarilla l vese la cara para quitar el exceso de grasa facial Esto har que la mascarilla se ajuste mejor y le permitir prolongar la vida de la almohadilla de la mascarilla Irritaci n nasal Sequedad Es posible que experimente sequedad de la nariz boca y o garganta durante el curso del tratamiento especialmente durante el invierno En muchos casos un humidificador puede resolver estas molestias P ngase en contacto con su m dico para que le aconseje Nariz taponada o con goteo Es posible que durante las primeras semanas de tratamiento estornude le gotee la nariz O la tenga taponada En muchos casos la irritaci n nasal se puede resolver usando un humidificador P ngase en contacto con su m dico para que le aconseje Use con energia de CC
5. Entrada de aire Entrada de ar AC input Entr e CA Entrada de CA Entrada CA 2008 ResMed Ltd 2008 ResMed Ltd 2008 ResMed Ltd D SETTING UPTHE VPAP AUTO INSTALLATION DE LA VPAP AUTO INSTALACION DEL VPAP AUTO MONTAGEM DO VPAP AUTO 2008 ResMed Ltd E HUMIDAIRE 3i AND S8 HUMIDAIRE 3i ET S8 HUMIDAIRE 3i y S8 H USING THE DATA CARD UTILISATION DE LA CARTE DE DONN ES HUMIDAIRE 3i e S8 USO DE LATARJETA DE DATOS COMO USAR O CARTAO DE DADOS HumidAire 3i 2008 ResMed Ltd BLANK MODULE MODULE VIERGE MODULO EN BLANCO MODULO DE PROTE O Data communications port Port de communication de donn es Puerto de comunicaci n de datos Porta de comunica o de dados O 2008 ResMed Ltd O 2008 ResMed Ltd G DATA CARD MODULE MODULE DE CARTE DE DONNEES MODULO TARJETA DE DATOS MODULO DE CART ES DE DADOS 2008 ResMed Ltd Note Some products not available in all regions Remarque certains de ces produits ne sont pas disponibles dans tous les pays Nota algunos productos no estan disponibles en todas las regiones Nota alguns produtos nao se encontram dispon veis em todas as regi es RESMED VPAP Auto User Guide Guide utilisateur Guia del usuario Manual do Usu rio Espa ol Fran ais English Portugu s ResMed Ltd Manufacturer 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia ResMed Corp US Designated
6. Indice alfab tico A Accesorios 6 Advertencias relativas al tratamiento 3 ajuste de mascarilla 14 22 calificaci n de estrellas 15 avi n 23 C cable de alimentaci n 5 26 conexi n 7 Caracter sticas de la presi n din mica 31 Compatibilidad electromagn tica 32 Componentes 5 configuraciones de la mascarilla 17 Consejos tiles 22 D Definiciones 1 E enchufes de alimentaci n 5 especificaciones t cnicas 31 32 F filtro de aire 5 26 cambio del 25 fuentes de alimentaci n 23 Fugas por la boca 22 Funciones del VPAP Auto 9 G Garantia 38 Garantia limitada 38 H HumidAire 3i 8 humidificador 6 limpieza 24 Informaci n m dica 2 Inicio del tratamiento 16 Instalaci n 7 Instrucciones de funcionamiento 13 Irritaci n nasal 22 L limpieza diaria 24 peri dica 24 semanal 24 limpieza de la mascarilla 24 Luz de fondo visor LCD y teclado 10 M mascarilla 5 ajuste de mascarilla 14 conexi n 7 posici n 26 puerto 26 tipo de mascarilla 17 mensajes de error 28 Men s 11 12 con humidificador 12 uso 10 m dulos conexi n 5 N Nariz tapada o con goteo 23 Nivel de ruido 32 O Ox geno suplementario 6 P Pantalla tiempo Usado 11 Pantalla de Adaptaci n 10 Pantalla de Rampa 10 pantalla Mascarilla 14 posici n del arn s 26 Preparaci n para el uso 7 presi n de aire 26 presi n ajuste de mascarilla 14 R recordatorios 18 cambiar filtro de aire 19 cambiar mascarilla 18 ins
7. Introdu o 1 Portugu s Informa es m dicas Para que serve o dispositivo VPAP Auto O VPAP Auto M indicado no tratamento da apn ia obstrutiva do sono AOS em pacientes com peso superior a 30 kg 66 lb Destina se ao uso hospitalar e dom stico PRECAU O APENAS PARA OS EUA A lei federal limita a venda deste dispositivo a m dicos ou por ordem destes Contra indica es A press o positiva das vias respirat rias poder ser contra indicada em certos pacientes que sofram das seguintes condi es doen a bolhosa do pulm o grave pneumot rax tens o arterial patologicamente baixa desidrata o fuga de l quido cerebrospinal trauma ou cirurgia craniana recente Avisos O manual dever ser lido na ntegra antes que o VPAP Auto seja utilizado As orienta es contidas neste manual n o substituem as instru es prescritas pelo m dico Os pacientes n o devem conectar dispositivos porta de comunica o de dados a menos que tenham sido orientados para isso pelo prestador de cuidados de sa de ou pelo m dico A porta de comunica o de dados s deve ser conectada a produtos ResMed A conex o de outros dispositivos pode provocar les es ou danos ao dispositivo VPAP Auto A unidade VPAP Auto s deve ser usada com m scaras e conectores recomendados pela ResMed ou por um m dico ou terapeuta de doen as respirat rias S use a m scara se o dispositivo VPAP Auto estiver ligado e funci
8. Starting Treatment The VPAP Auto unit should be assembled beside your bed with the air tubing and mask system connected See Setting Up the VPAP Auto on page 7 1 Plug the power cord into the power source A welcome message is displayed on the LCD screen The Ramp or Settling screen then appears Note If you have the HumidAire 3i attached please refer to the relevant user manual for operating instructions 2 Fit your mask as described in the mask user instructions 3 Lie down and arrange the air tubing so that it is free to move if you turn in your sleep 4 To start treatment simply breathe into the mask see SmartStart Air will begin flowing slowly and will build up to full operating pressure in about 10 to 15 seconds Note If the VPAP Auto does not start automatically you can also press the Start Stop key SmartStart The VPAP Auto has a function called SmartStart SmartStart enables your device to start automatically when you breathe into your mask If your clinican has enabled SmartStop your device will stop automatically when you take your mask off Stopping Treatment To stop treatment at any time remove your mask and press the Start Stop key or if your clinician has enabled SmartStop simply remove your mask and treatment will end Note SmartStop will not work if You have selected MIR FULL for your mask type Your clinician has enabled Leak Alert Using the Mask Fitting Feature You
9. Tipo de espiraci n TiMn espiraci n provocada al completarse el tiempo m nimo de retenci n de la inspiraci n TiMx espiraci n provocada al completarse el tiempo m ximo de retenci n de la inspiraci n C espiraci n provocada espont neamente dentro de TiMin y TiMax Tiempo de rampa Modo S modo CPAP El tiempo de rampa es una funci n que puede activar el m dico Si tiene dificultades para dormirse con la presi n total seleccione un tiempo de rampa Se suministrar un flujo de aire muy suave mientras se duerme La presi n ir increment ndose lentamente durante el tiempo de rampa seleccionado hasta alcanzar la presi n total de funcionamiento El m dico establecer un tiempo de rampa m ximo y usted podr seleccionar un valor por debajo de ese m ximo Tiempo de adaptaci n Modo VAuto El tiempo de adaptaci n es una funci n que puede activar el m dico Si tiene problemas para dormirse con el VPAP Auto en funcionamiento seleccione un tiempo de adaptaci n El flujo de aire permanecer en presi n m nima durante el periodo que usted establezca lo que le dar tiempo para dormirse Luego de este periodo el VPAP Auto podr aumentar la presi n en respuesta a episodios El m dico establecer un tiempo de rampa m ximo usted puede seleccionar cualquier valor hasta ese m ximo C mo seleccionar el tipo de mascarilla Despl cese hasta MASCARILLA y seleccione Cambiar tecla Izquierda Oprima las teclas Retroceso o
10. respecto al Ut 240V durante 25 ciclos durante 25 ciclos lt 5 del Ut lt 12V gt 95 de caida gt 95 de caida en con respecto al 240V Ut durante 5 seg durante 5 seg Campo magn tico 3 A m 3 A m Los campos magn ticos de de la frecuencia la frecuencia industrial industrial deben tener los niveles 50 60 Hz propios de un local tipico de CEI 61000 4 8 un entorno comercial u hospitalario tipico NOTA Ut es la tensi n de red de CA antes de la aplicaci n del nivel de prueba Continua en la pagina siguiente Especificaciones t cnicas 35 36 Gu a y declaraci n del fabricante inmunidad electromagn tica El equipo VPAP Auto est dise ado para ser utilizado en el entorno electromagn tico especificado a continuaci n El cliente o usuario del equipo VPAP Auto deber asegurarse de que sea utilizado en dicho entorno E Nivel de Prueba de Nivel de prueba 8 a y inmunidad CEI 60601 1 2 cumpli Entorno electromagn tico gu a miento Los equipos de comunicaciones por RF port tiles y m viles no deben ser usados cerca de parte alguna del equipo VPAP Auto incluidos los cables a una distancia menor que la recomendada calculada a partir de la ecuaci n aplicable a la frecuencia del transmisor Distancia de separaci n recomendada RF conducida 3 Vrms 3 Vrms d 1 17 VP CEI 61000 4 6 150 kHz a 80 MHz RF irradiada 10 V m 10 V m d 0 35 VP 80 MHz a 800 MHz CEI 61000 4 3 de 80 MHza 2 5 GHz d 0 70 VP 800 MHz a 2 5
11. 26 incorretamente A tomada de energia pode estar avariada A respira o n o suficientemente forte para ativar o SmartStart firmemente em ambas extremidades Experimente outra tomada Respire profundamente atrav s da m scara Problema Possivel causa A fuga de ar excessiva Solu o Ajuste a posi o da m scara e do arn s As tampas podem n o estar nas portas da m scara Volte a colocar as tampas Tubo de ar conectado incorretamente Conecte o tubo de ar firmemente em ambas as extremidades Tubo de ar dobrado ou perfurado Endireite ou substitua A unidade VPAP Auto n o p ra quando voc remove a sua m scara SmartStop est desativado Nota o SmartStop n o fica dispon vel se voc estiver utilizando uma m scara f cil ou se o alerta de fuga estiver ativado Ative o SmartStop se poss vel SmartStop encontra se ativado mas o gerador de fluxo n o p ra automaticamente quando voc remove a m scara Umidificador ou sistema de m scara utilizado incompat vel Use o equipamento somente da forma recomendada e fornecida pela ResMed Press o aumenta de modo impr prio Voc pode estar falando tossindo retendo voluntariamente a respira o por exemplo ao se virar na cama ou respirando de forma irregular Almofada da m scara est vibrando sobre a pele Almofada n o est bem posicionada Almofada n o foi bem posicion
12. Explanation When the PAP device is not in operation and the oxygen flow is left on oxygen delivered into the ventilator tubing may accumulate within the PAP machine enclosure and create a risk of fire This applies to most types of PAP machines Oxygen supports combustion Oxygen should not be used while you are smoking or in the presence of an open flame Always ensure airflow is being generated by the device before the oxygen supply is turned on Always turn the oxygen supply off before stopping the airflow from the device Note At a fixed rate of supplemental oxygen flow the inhaled oxygen concentration will vary depending on where the oxygen is introduced the pressure settings patient breathing pattern mask selection and leak rate Do not use the VPAP Auto if there are obvious external defects or unexplained changes in performance Do not open the VPAP Auto case There are no user serviceable parts inside Repairs and internal servicing should only be performed by an authorized service agent Explosion hazard do not use in the vicinity of flammable anesthetics Warnings Related to Treatment If you stop your PAP or bilevel treatment your sleep apnea will return immediately Always consult your clinician if you expect to be in a situation where you cannot use your VPAP Auto unit Medical Information English 3 If you are admitted to a hospital or prescribed any other form of medical treatment always i
13. Humidificateur HumidAire 3i L HumidAire 3i se fixe sur le devant de la VPAP Auto pour procurer une humidification chauffante Aucun autre accessoire n est requis pour l utiliser La VPAP Auto d tecte automatiquement la pr sence de l HumidAire 3i Il n est pas n cessaire de modifier le menu Veuillez vous r f rer au manuel utilisateur correspondant pour des informations plus d taill es AVERTISSEMENT V rifier que le r servoir est vide et bien sec avant de transporter l HumidAire 3i Lors de l utilisation du sac de transport syst matiquement ranger la VPAP Auto et I HumidAire 3i s par ment avec ce dernier dans la poche pr vue cet effet La VPAP Auto est maintenant pr te tre utilis e Pour commencer le traitement voir Instructions d utilisation page 14 Caract ristiques de la VPAP Auto Le panneau de contr le de la VPAP Auto comprend un clavier pour la navigation dans les menus et pour le r glage des param tres de traitement Touche de d placement Ecran LCD vers le haut Touche de gauche Touche de droite Touche de d placement vers le bas Touche Marche Arr t Figure 1 Clavier et cran LCD de la VPAP Auto L cran LCD est utilis pour afficher les menus et les autres donn es Les fl ches et le texte en minuscules sur la derni re ligne de I cran LCD vous invitent a utiliser les touches dans les menus Le clavier est utilis pour naviguer dans les menus a
14. Para conectar el VPAP Auto a una fuente de alimentaci n de 12 6 24 V de CC debe usar un transformador de DC 12 de ResMed Para m s detalles comun quese con su proveedor de equipamiento o con ResMed ADVERTENCIA El equipo no se debe conectar simult neamente a una fuente de alimentaci n de CA y a una de CC Viajes con el VPAP Auto Uso internacional Su generador de aire VPAP Auto tiene un adaptador de corriente interno que le permite funcionar en otros pa ses Puede funcionar con suministros de corriente de 100 240 V y 50 60 Hz No es necesario hacer ning n ajuste especial pero es probable que necesite un adaptador para la toma de corriente de la regi n en la que est usando el equipo Uso en un avi n Si tiene intenci n de usar su VPAP Auto en un avi n consulte al departamento de servicios m dicos de su aerol nea Si no se usan cables de datos externos el VPAP Auto cumple con los requisitos de la Parte 15 Clase B de la FCC Comisi n Federal de Comunicaciones de EE UU Nota No use e VPAP Auto cuando el avi n est despegando o aterrizando Modo de uso Espafiol 23 Limpieza y mantenimiento Debe efectuar regularmente la limpieza y el mantenimiento descritos en esta secci n Para tener instrucciones m s detalladas remitase al manual de la mascarilla Limpieza diaria Mascarilla Limpie la mascarilla de acuerdo con las instrucciones que se suministran con la misma Tubo de aire Desconecte el tubo
15. am a aparecer no visor LCD 2 Copie os dados para o cartao de dados Os dados come ar o a ser copiados automaticamente quando o cart o de dados for introduzido no m dulo correspondente A mensagem Cart o inserido Aguarde ser apresentada no visor LCD do VPAP Auto enquanto os dados s o copiados A c pia pode demorar at 30 segundos A mensagem C pia conclu da Remova o cart o ser apresentada no visor LCD quando os dados tiverem sido copiados e Remova o cart o de dados do m dulo Nenhum dado adicional ser copiado para o cart o depois que a mensagem C pia conclu da Remova o cart o for exibida mesmo que o cart o seja deixado no dispositivo Para adicionar dados ao cart o reintroduza o cart o e repita essas etapas 3 Remova o cart o de dados Segure a extremidade do cart o e puxe o para fora do m dulo H 3 4 Guarde o cart o de dados Seu cart o de dados dever ser guardado no envelope de resposta quando n o estiver em uso 5 Envie o cart o de dados ao m dico pelo correio Quando enviar o cart o de dados por correio para o m dico 1 Introduza o cart o no bolso apropriado do envelope de resposta Dobre o envelope 2 Coloque o envelope contendo o cart o em um envelope postal e lacre 3 Certifique se de que o nome e endere o do m dico est o presentes no envelope postal e fa a imediatamente o envio Como usar o cart o de dados para atualizar configura es
16. ant est sur marche Le d bit d air d livr par la VPAP Auto est insuffisant La dur e de rampe ou le temps d attente est utilis Le filtre a air est sale Le circuit respiratoire est entortill ou perc Le circuit respiratoire n est pas correctement raccord Le masque et le harnais sont mal mis en place Un ou des bouchons manquent au niveau du des port s du masque La pression requise pour le traitement a peut tre chang Attendez que la pression augmente ou modifiez la dur e de rampe ou le temps d attente Remplacez le filtre air D sentortillez ou remplacez le circuit respiratoire V rifiez le circuit respiratoire Ajustez la position du masque et du harnais Remplacez le s bouchon s Consultez votre clinicien pour ajuster la pression La VPAP Auto ne d marre pas lorsque vous respirez dans le masque Le cable d alimentation n est pas correctement branch La prise de courant est peut tre d fectueuse La respiration n est pas assez profonde pour d clencher SmartStart Branchez le cable d alimentation correctement aux deux extr mit s Essayez une autre prise de courant Respirez profond ment dans le masque Strat gie de d pannage Frangais 21 28 Probl me Cause possible Il y a une fuite excessive Solution Ajustez la position du masque et du harnais ll est possible que des bouchons manquent au niveau des ports
17. du masque Remplacez les le cas ch ant Le circuit respiratoire n est pas correctement raccord Raccordez le circuit respiratoire correctement aux deux extr mit s Le circuit respiratoire est entortill ou perc D sentortillez ou remplacez le circuit respiratoire La VPAP Auto ne s arr te pas lorsque vous retirez le La fonction SmartStop est d sactiv e Remarque SmartStop n est Activez SmartStop si cela est possible masque pas disponible si vous utilisez un masque facial ou si l alarme de fuite est activ e SmartStop est activ e l humidificateur ou le masque Utilisez uniquement mais l appareil ne s arr te pas automatiquement lorsque vous retirez votre masque utilis est incompatible l quipement recommand et fourni par ResMed La pression augmente de fa on inappropri e Vous parlez toussez retenez volontairement votre respiration p ex lorsque vous vous tournez dans le lit ou vous respirez intentionnellement d une fa on inhabituelle La bulle du masque vibre contre la peau La bulle n est pas correctement en place La bulle n est pas correctement mise en place ce qui provoque des fuites excessives vitez de parler lorsque vous portez un masque nasal et respirez le plus normalement possible Ajustez le harnais Ajustez le harnais ou remettez la bulle correctement en place Probleme Cause possible Le circuit respiratoire est en
18. e M scara Nasal Mirage Vista e M scara Nasal Ultra Mirage e M scara Nasal Ultra Mirage II e M scara Nasal Mirage Activa Sistemas de Almofadas Nasais Sistema de Almofadas Nasais Mirage Swift Sistema de Almofadas Nasais Mirage Swift II M scaras Faciais e M scara Facial Mirage Liberty e M scara Facial Mirage Quattro e M scara Facial Ultra Mirage Notas Alguns modelos n o se encontram dispon veis em certas regi es Os dispositivos ResMed foram projetados e fabricados de forma a proporcionarem um desempenho ideal com a utiliza o de m scaras ventiladas da ResMed Embora outros sistemas de m scaras possam ser utilizados o desempenho e a sa da de dados podem ser afetados Em modo VAuto apenas os sistemas de m scara da ResMed s o compat veis para uso com o VPAP Auto Seu m dico deve ajustar o VPAP Auto para uso com sua m scara particular O Sistema VPAP Auto Portugu s Umidificador Consulte a ilustra o na sec o B do folheto de ilustra es Poder ser necess rio utilizar um umidificador em caso de ressecamento do nariz da garganta ou da boca O VPAP Auto compat vel com o umidificador aquecido HumidAire 3i B 1 AVISO Somente o HumidAire 3i compat vel com o VPAP Auto Consulte os Avisos na p gina 2 Acess rios Consulte as ilustra es na se o C do folheto de ilustra es Os seguintes acess rios est o dispon veis para util
19. es n est pas correctement ins r e La carte ins r e n est pas une carte de donn es ResScan Vous avez peut tre retir la carte de donn es avant que les donn es n aient t copi es dessus V rifiez que la carte de donn es est ins r e avec la fl che dirig e vers le haut et pointant vers l appareil Utilisez une carte de donn es ResScan comme indiqu dans ce manuel Ins rez la carte de donn es nouveau et attendez que le message COPIE TERMINEE Retirez carte s affiche sur l cran LCD Le message suivant s affiche sur l cran LCD apr s que vous avez essay de mettre les r glages jour l aide de la carte de donn es REGL INVALIDES Retirez carte Les donn es d identification de la carte de donn es ne correspondent pas celles de votre appareil Contactez votre clinicien imm diatement Probleme Le message suivant s affiche sur l cran LCD apr s que vous avez essay de mettre les r glages jour l aide de la carte de donn es ERREUR REGLAGES Retirez carte Cause possible Erreur de donn es sur la carte de donn es Solution Contactez votre clinicien imm diatement Le message suivant ne s affiche PAS sur l cran LCD apr s que vous avez essay de mettre les r glages jour l aide de la carte de donn es CHARG REUSSI Retirez carte Les r glages n ont pas t mis jour Contactez votre clinicien imm diatement
20. n para volver a poner en marcha el equipo Si esto no logra que el mensaje desaparezca desconecte el cable de alimentaci n y despu s vuelva a conectarlo para poner nuevamente en marcha al equipo Aparece un mensaje de error en el visor ERRO SISTnnnn iLlamar a servicio Falla de un componente Registre el n mero de error y p ngase en contacto con el centro de servicio de ResMed Aparece un mensaje de error en el visor FUGA GRAVE Ajustar mascarilla Ha presentado niveles de fuga excesivamente altos durante m s de 20 segundos Verifique que el tubo de aire est debidamente conectado y que no haya fugas excesivas por la mascarilla Utilice la funci n Ajuste de mascarilla para ayudarle a obtener un ajuste adecuado Si este mensaje vuelve a aparecer consulte a su m dico Aparece un mensaje de error en el visor Exxxx en el cual xxxx define un error Falla de un componente Envie el VPAP Auto al servicio de mantenimiento 28 Problema Al tratar de actualizar las configuraciones por medio de una Tarjeta de datos aparece el siguiente mensaje en el visor Error tarjeta Quitar tarjeta Causa posible La Tarjeta de datos no se ha insertado correctamente La Tarjeta de datos se ha insertado s lo parcialmente Es posible que haya retirado la Tarjeta de datos antes de que la configuraci n se haya copiado en el VPAP Auto La tarjeta no es una Tarjeta de datos
21. ncia t cnica autorizada da ResMed Se achar que seu gerador de fluxo n o est funcionando adequadamente consulte Resolu o de problemas na p gina 26 Limpeza e manuten o Portugu s 25 Resolu o de problemas Quando ocorrer um problema tente as seguintes sugest es Se o problema n o puder ser resolvido contate o fornecedor do equipamento ou a ResMed N o tente abrir a unidade Problema O visor n o funciona Poss vel causa Energia n o conectada Solu o Certifique se de que o cabo de energia adequado se encontra conectado ao VPAP Auto e que o interruptor de energia caso dispon vel se encontra ligado Ar fornecido pelo Tempo de rampa ou Aguarde o aumento da press o VPAP Auto acomoda o est em uso de ar ou ajuste o tempo de insuficiente rampa ou acomoda o Filtro de ar est sujo Substitua o filtro de ar Tubo de ar dobrado ou Endireite ou substitua o tubo perfurado Tubo de ar conectado Verifique o tubo de ar incorretamente M scara e arn s n o foram Ajuste a posi o da m scara e posicionados corretamente do arn s Falta m a s tampa s na s Volte a colocar a s tampa s porta s de acesso da m scara A press o necess ria para Entre em contato com seu tratamento pode ter sido m dico para ajustar a press o alterada VPAP Auto n o Cabo de energia conectado Conecte o cabo de energia come a a funcionar quando voc respira pela m scara
22. o na se o E do folheto de ilustra es e seu manual do HumidAire 3i AVISO O VPAP Auto n o compat vel com umidificadores externos Umidificador HumidAire 3i O HumidAire 3i se prende frente do VPAP Auto para proporcionar uma umidifica o aquecida N o s o necess rios outros acess rios para sua utiliza o O VPAP Auto detecta automaticamente a presen a do HumidAire 3i N o necess rio realizar altera es no menu Consulte o manual do usu rio relevante para obter mais detalhes AVISO Certifique se de que o compartimento de gua est vazio e totalmente seco antes de transportar o HumidAire 3i e Ao usar a bolsa de transporte sempre separe a unidade VPAP Auto do HumidaAire 3i e coloque o HumidAire 3i na subdivis o apropriada O VPAP Auto j est pronto para ser utilizado Para iniciar o tratamento consulte Instru es operacionais na p gina 13 Caracteristicas do VPAP Auto O painel de controle do VPAP Auto inclui um teclado que permite navegar pelos menus e administrar o tratamento Tecla Para cima Visor LCD Tecla Esquerda ssa Tecla Iniciar Parar a START STOP Dus i Tecla Direita Tecla Para baixo Figura 1 Teclado e visor LCD do VPAP Auto O visor LCD utilizado para apresentar os menus e outros dados As setas e o texto em min sculas que aparecem na linha inferior do visor LCD solicitam o uso das teclas dentro dos menus O teclado utilizado para per
23. tre d marr e qu partir de l cran RAMPE ou ATTENTE En mode VAuto la pression d ajustement du masque est 10 cm H30 Lorsque l appareil est en mode CPAP la pression d ajustement du masque est 10 cm H20 ou la pression fixe de traitement si celle ci est sup rieure 10 cm H20 Lorsque l appareil est en mode S la pression d ajustement du masque est 10 cm H20 ou l EPAP si celle ci est sup rieure 10 cm H320 Les fonctions Alarme fuite et SmartStop sont d sactiv es lorsque la fonction d ajustement du masque est utilis e 3 Ajustez votre masque la bulle du masque et le harnais jusqu ce que le masque soit a la fois stable et confortable Une fois que cela est fait v rifiez la note d ajustement du masque en toiles sur l cran LCD Le Tableau 2 donne la signification des notes d ajustement du masque Instructions d utilisation Fran ais 15 16 Remarque si quelqu un d autre peut v rifier la note d ajustement de votre masque votre place allongez vous pour ajuster le masque la bulle et le harnais Tableau 2 Signification des notes d ajustement du masque en toiles Note en toiles D finition RENTE Excellent REE Tr s bon KKK Bon Ajuster le masque Ajuster le masque Ajuster le masque 4 Au bout de trois minutes la pression r gl e est restaur e et le traitement commence Si vous ne voulez pas attendre trois minutes maintenez la touche Marche Arr t enfonc e penda
24. Avance hasta que vea el tipo de mascarilla que desee La siguiente tabla muestra la configuraci n que se debe seleccionar para cada tipo de mascarilla Modo de uso Espafiol Tabla 3 Configuraciones de los tipos de mascarillas Configuraciones Mascarilla ULTRA Mascarilla Nasal Ultra Mirage Mascarilla Nasal Ultra Mirage II MIR FACIAL Mascarilla Facial Mirage Liberty Mascarilla Facial Mirage Quattro Mascarilla Facial Ultra Mirage ACTIVA Mascarilla Nasal Mirage Activa SWIFT Sistema de Almohadillas Nasales Mirage Swift Sistema de Almohadillas Nasales Mirage Swift II ESTANDAR Mascarilla Nasal Mirage Vista Mensajes en el visor del VPAP Auto Su m dico tal vez haya configurado el VPAP Auto para que le recuerde acerca de hechos importantes tales como cambiar la mascarilla insertar la Tarjeta de datos si su equipo es compatible con ella etc El mensaje recordatorio aparece en el visor s lo cuando el equipo no est suministrando tratamiento Cuando aparece un mensaje la luz de fondo del visor parpadea Su m dico puede configurar cualquiera de los siguientes recordatorios en su visor Mensaje Descripci n Acci n INSERTAR Aparece si su Inserte la Tarjeta de datos consulte la TARJETA equipo es secci n H de la hoja de figuras y siga las compatible con la instrucciones que su m dico le haya dado Tarjeta de datos Una vez que lo haya hecho el mensaje desaparecer del visor Si oprime la tecla Izquierda A
25. Do not immerse the unit or power cord in water Always unplug the unit before cleaning and be sure itis dry before plugging back in The mask system and air tubing are subject to normal wear and tear Inspect them regularly for damage 22 Replacing the Air Filter To replace the air filter English 1 Remove the air filter cover at the back of the VPAP Auto Air filter cover 2 Remove and discard the old air filter 3 Insert a new filter with the blue tinted side facing out from the device 4 Replace the air filter cover Inspect the air filter every month to check if it is blocked by dirt or contains holes With normal use of an VPAP Auto the air filter needs to be replaced every six months or more often if your device is in a dusty environment WARNING E Do not wash the air filter The air filter is not washable or reusable The air filter cover protects the device in the event of accidental liquid spillage onto the device Ensure the air filter and air filter cover are fitted at all times Servicing 7 ends Do not attempt to open the VPAP Auto case There are no user serviceable parts inside Inspection and repair should only be performed by an authorized agent Under no circumstances should you attempt to service or repair the flow generator yourself This product VPAP Auto should be inspected by an authorized ResMed service center 5 years from the date of manufacture Prior to this the device is inten
26. E apa de E mascarillas o conectores especiales cuyos orificios de ventilaci n permiten un flujo continuo de aire hacia fuera de la mascarilla Puede haber puertos integrados en la mascarilla o en los conectores pr ximos a la mascarilla Mientras el equipo est encendido y funcionando correctamente el aire fresco del dispositivo desplaza el aire espirado hacia fuera de la mascarilla a trav s de sus orificios de ventilaci n No obstante cuando el equipo no esta funcionando no se suministrara suficiente aire fresco a trav s de la mascarilla y es posible que se vuelva a respirar aire exhalado El volver a respirar aire exhalado durante varios minutos puede conducir en algunas circunstancias a la asfixia Esto se aplica a la mayoria de los modelos de equipos PAP En caso de cese en el suministro de energia o de malfuncionamiento del equipo se debe quitar la mascarilla al paciente El VPAP Auto puede configurarse para suministrar presiones de hasta 20 cm H50 En el caso improbable de que se produzcan ciertos desperfectos en el funcionamiento este dispositivo puede suministrar presiones de hasta 30 cm H 0 Si se utiliza oxigeno con este equipo el flujo del mismo deber estar cerrado mientras el equipo no est en funcionamiento Si se deja activado el oxigeno mientras el equipo no esta funcionando desconecte el oxigeno y espere 60 minutos antes de encender el equipo nuevamente Explicacion Mientras el equipo PAP no est func
27. ResScan Soluci n Verifique que la Tarjeta de datos est insertada con la flecha hacia arriba y apuntando hacia el equipo Verifique que el equipo est encendido y en modo de espera antes de insertar la Tarjeta de datos Verifique que la Tarjeta de datos est insertada hasta el fondo en la ranura del m dulo Tarjeta de datos Vuelva a insertar la Tarjeta de datos y espere a que aparezca en el visor el mensaje Configuraci n correcta quitar tarjeta Utilice Unicamente una Tarjeta de datos ResScan Al tratar de copiar datos a una Tarjeta de datos aparece el siguiente mensaje en el visor Error tarjeta quitar tarjeta La Tarjeta de datos no se ha insertado correctamente La tarjeta no es una Tarjeta de datos ResScan Es posible que haya retirado la Tarjeta de datos antes de que el copiado de datos haya finalizado Verifique que la Tarjeta de datos est insertada con la flecha hacia arriba y apuntando hacia el equipo Utilice una Tarjeta de datos ResScan tal como se especifica en este manual Vuelva a insertar la Tarjeta de datos y espere a que aparezca en el visor el mensaje Copia completa quitar tarjeta Al tratar de actualizar las configuraciones por medio de una Tarjeta de datos aparece el siguiente mensaje en el visor Configuraci n no v lida quitar tarjeta Los datos identificatorios en la Tarjeta de datos no coinciden con los datos de su equipo Comun quese inmedia
28. Ti2ts 4 last 5 breaths Note Set values are those selected by the clinician Figure 5 Treatment screens all modes The treatment screens contain the following information Treatment mode Mode of treatment set by your clinician Options are CPAP S and VAuto Ramping indicator CPAP mode S mode Appears if the VPAP Auto is in ramp mode This disappears once the ramp time has elapsed Settling indicator VAuto mode Appears if the VPAP Auto is in settling mode This disappears once the settling time has elapsed Set pressure s In CPAP mode this displays the set treatment pressure centimeters of water In S mode it displays exhalation and inhalation pressures centimeters of water In VAuto mode it displays the EPAP and IPAP pressures centimeters of water Apnea indicator CPAP mode VAuto mode Visual indicator that displays an A to indicate an apnea is occurring Operating Instructions 15 Pressure bar graph Graphical display of the changing pressure Leak Current mask leak liters per minute Respiratory rate Number of breaths per minute Minute ventilation Volume of air inhaled per minute liters per minute Tidal volume Volume of air inhaled per breath milliliters per breath Breath phase expiration This screen item displays in the format breath type phase display expiration type as shown below eg S TiMn Breath type S spontaneous Phase display inspiration blank expiration Expira
29. a activ e sur votre donn es Une fois que vous avez termin le appareil message dispara t de l cran Vous pouvez galement I effacer en appuyant sur la touche de gauche Ok REMPLACER Peut s afficher Appuyez sur la touche de gauche Ok pour MASQUE lorsque votre effacer le message de I cran et remplacez masque doit tre remplac votre masque par un neuf Instructions d utilisation 19 20 Message APPEL CLINICIEN Description Peut s afficher pour vous rappeler de contacter votre clinicien par exemple pour discuter de votre traitement Action Appuyez sur la touche de gauche Ok pour effacer le message de l cran et contactez votre clinicien REMPLACER FILTRE Peut s afficher pour vous rappeler de remplacer le filtre air de votre appareil Appuyez sur la touche de gauche Ok pour effacer le message de I cran et remplacez le filtre air ENTRETIEN ECHU Peut s afficher pour vous rappeler de retourner votre appareil pour entretien Appuyez sur la touche de gauche Ok pour effacer le message de l cran Messages personnalis s rappels perso Votre clinicien peut galement r gler d autres rappels par exemple pour que vous retourniez l appareil ou que vous appeliez une personne ou un num ro particulier Appuyez sur la touche de gauche Ok pour effacer le message de I cran Modules Remarque ne retirez pas les modules lorsque la VPAP
30. after you try to update settings using the Data Card Card Error Remove Card 26 The Data Card is not inserted correctly The Data Card is only partly inserted You may have removed the Data Card before settings were copied to the VPAP Auto Ensure that the Data Card is inserted with the arrow facing up and pointing towards the device Ensure that the device is switched on and in standby mode before you insert the Data Card Ensure that the Data Card is inserted into the slot on the Data Card module as far as it will go Reinsert the Data Card and wait for the Settings Success Remove Card message to appear on the LCD Problem Possible Cause The card is not a ResScan Data Card Solution Only use a ResScan Data Card The following message is displayed on the LCD after you try to copy data to a Data Card Card Error Remove Card The Data Card is not inserted correctly The card is not a ResScan Data Card You may have removed the Data Card before data was copied to it Ensure that the Data Card is inserted with the arrow facing up and pointing toward the device Use a ResScan Data Card as specified in this manual Reinsert the Data Card and wait for the Copy Complete Remove Card message to appear on the LCD The following message is displayed on the LCD after you try to update the settings using the Data Card Settings Invalid Remove Card The identification detai
31. c danos ou contamina es provocado a s por fuma a de cigarro cachimbo charuto ou outras fontes d danos provocados pelo derrame de gua sobre ou dentro do gerador de fluxo A garantia deixa de ser v lida se o produto for vendido ou revendido fora da regi o da compra original Os pedidos de reparo ou substitui o de um produto defeituoso no mbito da garantia devem ser feitos pelo consumidor original no local de compra Esta garantia substitui todas as outras expl citas ou impl citas incluindo qualquer garantia impl cita de comerciabilidade ou de adequabilidade para determinada utiliza o Algumas regi es ou estados n o permitem limita es de tempo sobre a dura o de uma garantia impl cita pelo que a limita o acima pode n o se aplicar ao seu caso A ResMed n o respons vel por quaisquer danos incidentais ou consequentes alegadamente decorrentes da venda instala o ou uso de um produto ResMed Algumas regi es ou estados n o permitem a exclus o ou limita o de danos incidentais ou consequentes pelo que a limita o acima pode n o se aplicar ao seu caso Esta garantia confere lhe direitos legais espec ficos e pode ter outros direitos que variam segundo a regi o Para mais informa es sobre seus direitos de garantia entre em contato com o revendedor local da ResMed ou os escrit rios da ResMed R001 307 2 05 06 Indice remissivo A Acessorios 6 aeronave 23 ajuste da mascara 14 22 classi
32. can use the VPAP Auto mask fitting feature to help you fit your mask properly This feature delivers air pressure for a three minute period prior to starting treatment during which you can check and adjust your mask fit to minimize leaks Operating Instructions 13 14 Note Make sure that the mask setting on the MASK screen is the same as the mask you are using To use the mask fitting feature Fit your mask as described in the mask user instructions Hold down the Start Stop key for at least three seconds until air pressure delivery starts The following display will appear on the LCD screen indicating that the mask fitting feature is operating Your device will ramp to the mask fit pressure and will remain at this pressure for three minutes The LCD also displays a mask fit star rating See Table 2 MASK FIT KKKKK excelnt mask fit star rating Notes The mask fit star rating display disappears after three minutes The mask fitting feature can only be started from the RAMP or SETTLING screen When the device is in VAuto mode the mask fit pressure is 10 cm H 0 When the device is in CPAP mode the mask fit pressure is the set treatment pressure or 10 cm H20 whichever is greater When the device is in S mode the mask fit pressure is EPAP or 10 cm H 0 whichever is greater e Leak Alert and SmartStop functions are disabled while using Mask Fit Adjust your mask mask cushion and headgear until you have a sec
33. clinician has provided a Data Card with new device settings e With the device in standby RAMP or SETTLING mode insert the Data Card into the slot on the Data Card module Updating will start automatically The Card Inserted Please Wait message is displayed on the LCD while updating is in progress Updating takes up to 30 seconds The Settings Success Remove Card message is displayed on the LCD if the settings were updated successfully Note This message only appears once If you re insert the Data Card after you have updated your settings this message is not displayed Remove the Data Card from the Data Card module Store the Data Card in its mailback envelope when not in use WARNING If your clinician has told you to use this Data Card to update the settings on your device and the Settings Success message does not appear contact your clinician immediately Helpful Hints Starting Out Mouth Leaks When using a nasal mask try to keep your mouth closed during treatment Air leaks from your mouth can decrease the effectiveness of your treatment If mouth leaks are a problem a full face mask or chin strap may help Contact your clinician or equipment supplier for further details Mask Fitting The flow generator delivers the most effective treatment when the mask is well fitted and comfortable Treatment can be affected by leaks so it is important to eliminate any leaks that may arise If you have pro
34. da do transmissor em Watts W de acordo com o fabricante do transmissor NOTA 1 a 80 MHz e 800 MHz aplic vel o afastamento para a maior faixa de frequ ncia NOTA 2 essas diretrizes podem n o se aplicar a todas as situa es A propaga o eletromagn tica afetada pela absor o e reflex o de estruturas objetos e pessoas Especifica es t cnicas Portugu s 37 38 Garantia limitada A ResMed garante que seu produto ResMed esta livre de defeitos materiais e de m o de obra durante o per odo de tempo abaixo especificado a partir da data de compra pelo consumidor original Esta garantia n o transfer vel Per odo da Produto aan garantia Umidificadores da ResMed ResControl ResLink 1 Ano ResTraxx Geradores de fluxo da ResMed 2 Anos Acess rios sistemas de m scara incluindo arma o da 90 Dias m scara almofada arn s e tubo Exceto dispositivos de utiliza o nica Nota alguns modelos n o se encontram dispon veis em certas regi es Se o produto apresentar defeito em condi es normais de uso a ResMed consertar ou substituir a seu crit rio o produto ou componente defeituoso Esta Garantia Limitada n o cobre a danos provocados por uso incorreto uso abusivo modifica o ou altera o do produto b consertos efetuados por empresa de assist ncia t cnica que n o tenha sido expressamente autorizada pela ResMed para efetuar tais servi os
35. de aire de la unidad VPAP Auto y del humidificador si se esta usando uno y cuelgue el tubo de aire y la mascarilla en un lugar limpio y seco hasta el pr ximo uso Humidificador Si est utilizando un humidificador l mpielo siguiendo las instrucciones del manual del usuario del humidificador Limpieza semanal 1 Separe el tubo de aire de la unidad VPAP Auto y de la mascarilla 2 Lave el tubo de aire en agua tibia con un detergente suave Enju guelo bien cu lguelo y d jelo secar 3 Antes del pr ximo uso monte la mascarilla y el arn s seg n las instrucciones para el usuario 4 Vuelva a conectar el tubo de aire a la salida de aire y a la mascarilla Limpieza peri dica 1 Limpie el exterior de la unidad VPAP Auto con un pa o h medo y un detergente l quido suave 2 Examine el filtro de aire para verificar que no tenga obstrucciones ni agujeros consulte Cambio del filtro de aire en la p gina 25 ADVERTENCIA J Peligro de electrocuci n No sumerja la unidad ni el cable de alimentaci n en agua Siempre desconecte el equipo antes de limpiarlo y aseg rese de que est seco antes de conectarlo nuevamente La mascarilla y el tubo de aire estan sujetos a un desgaste natural por el uso Inspecci nelos regularmente para verificar que no est n danados 24 Cambio del filtro de aire Para cambiar el filtro de aire 1 Retire la cubierta del filtro de aire en la parte trasera del VPAP Auto Cubierta
36. de fuite Utilisation de la fonction d ajustement du masque Vous pouvez galement vous servir de la fonction d ajustement du masque de la VPAP Auto pour vous aider a mettre votre masque correctement en place Cette fonction g n re une pression d air pendant trois minutes avant le d but du traitement pour permettre la v rification et l ajustement du masque dans le but de minimiser les fuites Remarque assurez vous que l option de masque s lectionn e l cran MASQUE correspond au masque que vous utilisez Pour utiliser la fonction d ajustement du masque 1 Mettez votre masque comme indiqu dans son mode d emploi 2 Maintenez la touche Marche Arr t enfonc e pendant au moins trois secondes jusqu ce que le d bit d air d marre Le message suivant s affiche sur l cran LCD pour indiquer que la fonction d ajustement du masque est activ e Votre appareil augmente progressivement a pression jusqu la pression d ajustement du masque qu il maintient pendant trois minutes Une note d ajustement du masque en toiles est galement affich e sur l cran LCD Pour de plus amples informations reportez vous au Tableau 2 Signification des notes d ajustement du masque en toiles page 16 AJUS MSQ xxxxkx excel note d ajustement du masque en toiles Remarques La note d ajustement du masque en toiles dispara t au bout de trois minutes La fonction d ajustement du masque ne peut
37. de l utiliser autrement vous devez vous assurer qu elle fonctionne normalement lorsqu elle est plac e l endroit o elle sera utilis e ll est d conseill d utiliser des accessoires p exemple des humidificateurs autres que ceux sp cifi s dans ce manuel Ils peuvent entra ner une augmentation des missions ou une r duction de limmunit de la VPAP Auto Caract ristiques 35 36 Guide et d claration du fabricant Immunit lectromagn tique La VPAP Auto est pr vue pour une utilisation dans l environnement utilisateur de la VPAP Auto doit s assurer que celle ci est utilis e dans un dessous Le client ou environnement de ce ype ectromagn tique d crit ci Essai de E a Environnement contr le de Niveau d essal Niveau de lectromagn tique b oe CEI 60601 1 2 conformit a limmunit Guide D charge Contact 6 kV Contact 6 kV Les sols doivent tre en lectrostatique Air 8 kV Air 8 kV bois en ciment ou carrel s CEI 61000 4 2 Si le rev tement des sols est synth tique l humidit relative doit tre d au moins 30 Transitoires 2 kV pour les 2 KkV La qualit du secteur lectriques lignes lectrique doit tre celle rapides Salve d alimentation d un environnement CEI 61000 4 4 1 kV pour les Sans objet commercial ou hospitalier lignes typique d alimentation de signalisation Surtension 1 kV en mode 1 kV en mode La qualit du secteur CEI 61000 4 5 diff ren
38. declaraci n del fabricante Emisiones e inmunidad electromagn ticas Gu a y declaraci n del fabricante emisiones electromagn ticas El equipo VPAP Auto est dise ado para ser utilizado en el entorno electromagn tico especificado a continuaci n El cliente o usuario del equipo VPAP Auto deber asegurarse de que sea utilizado en dicho entorno Prueba de emisiones Cumplimiento el electromagn tico Emisiones de RF CISPR11 Grupo 1 El equipo VPAP Auto usa energ a de RF s lo para su funcionamiento interno Por lo tanto sus emisiones de RF son muy bajas y es improbable que provoquen interferencias en equipos electr nicos cercanos Emisiones de RF CISPR 11 con Clase B El equipo VPAP Auto es apropiado adaptador serial para ser usado en todos los mbitos incluidos mbitos dom sticos y Emisiones de RF CISPR 11 con Clase B aqu llos conectados directamente a la adaptador USB red p blica de bajo voltaje que abastece a los edificios destinados a Emisiones arm nicas Clase A vivienda CEI 61000 3 2 Fluctuaciones de voltaje Cumple Emisiones de parpadeo flicker CEI 61000 3 3 Clase B para todas las configuraciones del sistema excepto cuando se conecta un ResLink con ox metro a un equipo VPAP Auto conectado a la alimentaci n a trav s de un adaptador DC 12 en cuyo caso el sistema cumple con la Clase A La Clase A puede ser utilizada en todos los mbitos a excepci n de los mbitos dom s
39. del filtro de aire 2 Retire y deseche el filtro de aire usado 3 Inserte un filtro nuevo coloc ndolo con el lado pintado de azul hacia fuera del equipo 4 Vuelva a colocar la cubierta del filtro de aire Inspeccione el filtro de aire todos los meses para verificar que no est bloqueado por suciedad y que no haya agujeros Con el uso normal de un VPAP Auto el filtro de aire tendr que cambiarse cada seis meses o m s a menudo si el equipo se encuentra en un ambiente con mucho polvo dl No lave el filtro de aire El filtro de aire no es lavable ni reutilizable La cubierta del filtro de aire protege al dispositivo en caso de derrame accidental de l quidos sobre el mismo Aseg rese de que el filtro de aire y la cubierta del filtro est n instalados en todo momento Servicio de mantenimiento PRECAUCI N No intente abrir la carcasa del VPAP Auto No hay piezas dentro que el usuario pueda reparar e Lainspecci n y las reparaciones deber n ser efectuadas nicamente por un agente de servicio autorizado Bajo ninguna circunstancia deber intentar dar servicio o reparar el generador de aire usted mismo Al cumplirse 5 a os de su fabricaci n este producto VPAP Auto debe ser inspeccionado por un centro de servicio autorizado por ResMed Hasta ese momento el equipo est dise ado para funcionar de manera segura y fiable siempre que se use y se mantenga de acuerdo con las instrucciones suministradas por ResMed Cuand
40. dysfonctionnement de l appareil retirer le masque La VPAP Auto peut tre r gl e pour d livrer des pressions allant jusqu 20 cm H20 Dans le cas peu probable d une panne les pressions peuvent s lever jusqu 30 cm H20 Si de l oxyg ne est utilis avec cet appareil l alimentation en oxyg ne doit tre ferm e lorsque l appareil n est pas en mode de fonctionnement Si l alimentation en oxyg ne a t laiss e ouverte avec l appareil arr t d connecter l alimentation en oxyg ne puis attendre 60 minutes avant de remettre l appareil sous tension Explication lorsque l appareil de pression positive n est pas en marche et que l alimentation en oxyg ne n est pas coup e l oxyg ne d livr dans le circuit d air peut s accumuler dans l appareil et cr er un risque d incendie Cela vaut pour la plupart des appareils de pression positive _ l oxyg ne est inflammable Ne pas fumer ni approcher de flamme nue de l appareil lors de l utilisation d oxyg ne Syst matiquement v rifier qu un d bit d air est g n r par l appareil avant d ouvrir l alimentation en oxyg ne Syst matiquement couper l alimentation en oxyg ne avant d arr ter le d bit d air de l appareil Remarque lorsque de l oxyg ne additionnel est d livr un d bit fixe la concentration de l oxyg ne inhal varie en fonction du point d entr e de l oxyg ne des r glages de pression de la respiration du patient du masque s lectionn ai
41. encontra em funcionamento O dispositivo aumentar a press o at atingir a press o de ajuste da m scara e a manter por tr s minutos O visor LCD tamb m apresenta uma classificac o de ajuste da m scara por estrelas Consulte a Tabela 2 Defini es da classifica o por estrelas do ajuste da m scara na p gina 15 AJUM SC xxxxx excelnt classifica o por estrelas do ajuste da m scara Notas A tela de classifica o do ajuste da m scara desaparecer ap s 3 minutos e O recurso de ajuste da m scara s pode ser iniciado a partir da tela RAMPA ou ACOMODA O Quando o dispositivo estiver em modo VAuto a press o de ajuste da m scara ser de 10 cm H20 Quando o dispositivo estiver no modo CPAP a press o de ajuste da m scara ser a press o definida para o tratamento ou 10 cm H20 o que for maior Quando o dispositivo estiver no modo S a press o de ajuste da m scara ser EPAP ou 10 cm H 0 o que for maior As fun es de alerta de fuga e SmartStop ficam desativadas durante o uso do ajuste da m scara Ajuste a m scara a almofada da m scara e o arn s at obter um ajuste firme e confort vel Em seguida verifique a classifica o por estrelas do ajuste da m scara no visor LCD A Tabela 2 explica a classifica o por estrelas do ajuste da m scara Nota se houver uma pessoa por perto para verificar a classifica o por estrelas do ajuste da m scara voc poder ajustar a
42. equipo en modo de espera RAMPA o ADAPTACI N inserte la Tarjeta de datos en la ranura del m dulo Tarjeta de datos La actualizaci n se iniciar autom ticamente Durante la actualizaci n en el visor aparecer el mensaje Tarjeta insertada espere La actualizaci n tarda hasta un m ximo de 30 segundos e Sila configuraci n se actualiz correctamente en el visor aparecer el mensaje Configuraci n correcta quitar tarjeta Modo de uso Espa ol 21 Nota este mensaje aparece s lo una vez Si vuelve a insertar la Tarjeta de datos despu s de haber actualizado la configuraci n el mensaje no volver a aparecer e Retire la Tarjeta de datos del m dulo Tarjeta de datos Cuando no est en uso guarde la Tarjeta de datos en su sobre de retorno postal ADVERTENCIA Si su m dico le ha indicado que use la Tarjeta de datos para actualizar la configuraci n de su equipo y el mensaje Configuraci n correcta no aparece comuniquese inmediatamente con su m dico Consejos tiles Para comenzar Fugas por la boca Si utiliza una mascarilla nasal trate de mantener la boca cerrada durante el tratamiento Las fugas de aire por la boca pueden reducir la eficacia del tratamiento Silas fugas por la boca resultaran ser un problema usted se podr a beneficiar de una mascarilla facial o una correa para el ment n Para obtener m s informaci n p ngase en contacto con su m dico o con su proveedor de equipos
43. es Uso com alimenta o CC Use um conversor DC 12 da ResMed para conectar o VPAP Auto a uma fonte de energia de 12V ou 24V CC Contate o fornecedor de equipamento ou a ResMed para mais informa es AVISO Este dispositivo n o dever ser ligado a fontes de energia de corrente alternada e corrente cont nua simultaneamente Viagens com o VPAP Auto Uso internacional O seu gerador de fluxo VPAP Auto vem equipado com um transformador de energia interno que permite sua utiliza o em outros pa ses A unidade aceita fontes de alimenta o de 100 a 240V e 50 a 60Hz N o requer ajuste especial mas pode necessitar de um adaptador de tomada para a regi o em que ser usado Uso em aeronaves Consulte o departamento m dico da companhia a rea correspondente se tiver a inten o de usar o VPAP Auto em uma aeronave O VPAP Auto encontra se em conformidade com os requisitos US FCC Parte 15 Classe B se n o forem utilizados cabos de dados externos Nota n o use o VPAP Auto enquanto a aeronave estiver decolando ou pousando Instru es operacionais Portugu s 23 Limpeza e manuten o Realize regularmente a limpeza e manuten o descritas nesta se o Consulte o manual da sua m scara para mais informa es Limpeza di ria M scara Lave a m scara de acordo com as instru es fornecidas com a mesma Tubo de ar Desconecte o tubo de ar do VPAP Auto e umidificador caso esteja em uso e pendure o tubo e a
44. internado em um hospital ou se receber qualquer outro tipo de tratamento m dico informe sempre o pessoal m dico que esta sob tratamento com PAP ou de dois niveis E importante tamb m que entre em contato com o m dico respons vel pelo seu tratamento de apn ia do sono Se tiver uma infec o das vias respirat rias superiores do ouvido m dio ou do seio nasal entre em contato com seu m dico antes de continuar com o tratamento de PAP ou de dois n veis Voc poder ser aconselhado a interromper o tratamento at que a infec o seja eliminada Se continuar com o tratamento durante uma infec o certifique se de lavar a m scara e o tubo ap s cada utiliza o Precau es A baixas press es o fluxo atrav s das portas de exala o da m scara poder n o eliminar todo o g s expirado do tubo Poder ocorrer alguma reinala o O fluxo de ar para respira o produzido por este dispositivo poder estar 6 C 11 F acima da temperatura ambiente Tome cuidado no caso de a temperatura ambiente estar acima de 32 C 90 F Quando a alimenta o da rede el trica CA 100 240V CA n o estiver dispon vel utilize sempre o conversor DC 12 da ResMed O conversor DC 12 encontra se dispon vel como acess rio opcional O m dulo de cart es de dados ResScan caso tenha sido fornecido foi projetado para uso com dispositivos ResMed S utilize o m dulo de cart es de dados ResScan caso tenha sido fornecido da forma especific
45. n durante al menos tres segundos y el tratamiento comenzar inmediatamente Si oprime la tecla Inicio Detenci n durante menos de tres segundos el equipo volver al modo de espera se mostrar la pantalla de RAMPA o la de ADAPTACI N Modo de uso Espafiol 15 16 Modo CPAP Modo S Modo VAuto Las primeras pantallas s lo aparecen si se selecciona Rampa o Adaptaci n Indicador de Modo Rampa Indicador de Modo Rampa Indicador de Modo Adaptaci n Presi n EPAP configurada EPAP IPAP Presi n CPAP Presi n IPAP configurada VA ADAP C RAMPA 8 0 RAMPA 8 0 11 0 8 0 11 0 A gt gt gt gt PS 3 0 A gt 4 salir gt gt gt gt PS 3 0 PS configurada Presi n de soporte VAUTO 8 0 11 0 A gt gt gt gt PS 30 Modo SPONT 8 0 11 0 gt gt gt gt LPS 30 Gr fica de presi n Indicador de apnea Fuga Ventilaci n minuto l min Frecuencia respiratoria rpm FU 24L min FR 12 k Volumen corriente ml VM 12 0 t VC 1000 Fila de arriba Unicamente modo S y VAuto Configuraci n de TiM x seg Relaci n l E media ltimas 5 respiraciones Respiraci n fase espiraci n Tiempo medio de inspiraci n ltimas 5 respiraciones S TiMn TiMx 4 0 Ti21s 1 1 6 Nota los valores configurados son aqu llos seleccionados por el m dico Figura 5 Pantallas de tratamiento todos los modos Las pantallas de tratamiento con
46. ni obstru ni perc voir Remplacement du filtre air page 26 AVERTISSEMENT J Risque de chocs lectriques Ne pas immerger l appareil ni le c ble d alimentation dans l eau Syst matiquement d brancher l appareil avant de le nettoyer et v rifier qu il est bien sec avant de le rebrancher Le masque et le circuit respiratoire subissent une usure normale Les inspecter r guli rement pour v rifier qu ils ne sont pas endommag s Nettoyage et entretien 25 Remplacement du filtre a air Pour remplacer le filtre a air 1 Retirez le couvercle du logement du filtre air l arri re de la VPAP Auto Couvercle du logement du filtre air 2 Retirez et jetez le filtre air usag 3 Ins rez un nouveau filtre air avec la face bleue dirig e vers l ext rieur 4 Remettez le couvercle du logement du filtre air en place Inspectez le filtre air une fois par mois pour v rifier qu il n est ni bloqu par des impuret s ni perc Dans des conditions normales de fonctionnement le filtre air de la VPAP Auto doit tre remplac tous les six mois ou plus souvent si votre appareil se trouve dans un environnement poussi reux AVERTISSEMENT Ne pas laver le filtre air Il n est ni lavable ni r utilisable Le couvercle du logement du filtre air prot ge l appareil contre tout d versement accidentel de liquides Veiller ce que le filtre air et le couvercle de son logement soient to
47. port de communication de donn es sauf si son prestataire de sant ou son m decin lui a demand de le aire Seuls les produits ResMed peuvent tre connect s au port de communication de donn es La connexion d autres appareils peut causer des blessures ou endommager la VPAP Auto La VPAP Auto doit tre utilis e uniquement avec les masques et raccords recommand s par ResMed un m decin ou un th rapeute respiratoire Le masque ne peut tre port que si la VPAP Auto est sous tension et si elle onctionne correctement Les orifices de ventilation du masque ne doivent jamais tre obstru s Explication la VPAP Auto est con ue pour tre utilis e avec des masques ou raccords sp ciaux poss dant des orifices de ventilation qui permettent l coulement continu de l air hors du masque Des ports peuvent tre int gr s au masque ou des raccords proches du masque Lorsque l appareil est sous tension et qu il fonctionne correctement de l air propre provenant de l appareil expulse l air expir via les orifices de ventilation du masque Cependant lorsque l appareil ne fonctionne pas le d bit d air propre d livr dans le masque est insuffisant et une r inhalation de l air expir peut se produire Si la r inhalation de l air expir dure plus de quelques minutes elle peut dans certains cas entra ner une suffocation Cela vaut pour la plupart des appareils de pression positive En cas de coupure de courant ou de
48. que la configuraci n de la mascarilla en la pantalla MASCARILLA sea la recomendada para la mascarilla que est usando consulte la tabla en C mo seleccionar el tipo de mascarilla en la p gina 17 El VPAP Auto est ya listo para ser utilizado D 4 Preparaci n para el uso Espa ol 7 Uso del humidificador Consulte la figura en la secci n E de la hoja de figuras y el manual del HumidAire 3i ADVERTENCIA gt El VPAP Auto no es compatible con humidificadores externos Humidificador Humidaire 3i El HumidAire 3i se conecta en la parte frontal del VPAP Auto para proporcionar humidificaci n t rmica No se requiere ning n otro accesorio para su utilizaci n El VPAP Auto autom ticamente detecta la presencia del HumidAire 3i No se necesita realizar cambios en el men Para m s detalles consulte el manual del usuario correspondiente ADVERTENCIA Aseg rese de que la camara de agua est vac a y completamente seca antes de transportar el HumidAire 3i Cuando use la bolsa para viaje siempre separe la unidad VPAP Auto del Humidaire 3i y coloque a ste ltimo en su bolsa El VPAP Auto est listo para ser utilizado Para comenzar el tratamiento consulte Modo de uso en la p gina 13 Caracteristicas del VPAP Auto El panel de control de la unidad VPAP Auto incluye un teclado para navegar por los menus y proporcionar el tratamiento a Visor ecla Retroceso Tecla Izquierda T
49. que la presi n del aire aumente o modifique el Tiempo de rampa o el Tiempo de adaptaci n Cambie el filtro de aire Enderece o cambie el tubo Revise el tubo de aire Ajuste la posici n de la mascarilla y del arn s Vuelva a poner el los tap n es Consulte a su m dico para que cambie dicha presi n El VPAP Auto no se pone en marcha al respirar en la mascarilla El cable de alimentaci n no est debidamente conectado La toma de corriente puede estar defectuosa La respiraci n no es lo suficientemente profunda para hacer funcionar la SmartStart Conecte el cable de alimentaci n firmemente en ambos extremos Pruebe otro enchufe de alimentaci n Inhale y exhale profundamente a trav s de la mascarilla Problema Causa posible Hay una fuga excesiva Soluci n Ajuste la posici n de la mascarilla y del arn s Es posible que falten los tapones de los puertos de acceso de la mascarilla Vuelva a colocarlos El tubo de aire no esta debidamente conectado Con ctelo firmemente en ambos extremos El tubo de aire est torcido o roto Enderece o cambie el tubo El VPAP Auto no se detiene al quitarse la mascarilla La funci n SmartStop est desactivada Nota SmartStop no est disponible si est usando una mascarilla facial o si la Alerta de fuga est activada Active SmartStop si fuese posible SmartStop est activada pero el generador de aire no se de
50. r tro clairage cran LCD et clavier 10 rhinorrh e ou nez bouch 23 S s cheresse 23 strat gie de d pannage 27 T temps d attente 11 18 27 touche de d placement vers le bas 10 touche de d placement vers le haut 10 touche de droite 10 touche de gauche 10 touche Marche Arr t 10 tuyau air entortill 27 U utilisation 8 utilisation l tranger 24 utilisation d un humidificateur 8 utilisation des menus 10 utilisation en avion 24 V voyage 24 VPAP Auto dimensions 33 r paration 26 RESMED VPAP Auto DISPOSITIVO DE PRESI N POSITIVA EN LAS V AS RESPIRATORIAS Gu a del usuario Espa ol Espa ol Indice Introduccion Definiciones Responsabilidad del usuario propietario Informaci n m dica Para qu esta disenado el equipo VPAP Auto Contraindicaciones Advertencias Precauciones Sistema VPAP Auto Mascarilla Oxigeno suplementario Preparaci n para el USO Configuraci n de VPAP Auto Montaje de la mascarilla Modo de uso Inicio del tratamiento SmartStart Parada del tratamiento Uso de la funci n Ajuste de mascarilla Mensajes en el visor del VPAP Auto M dulos Consejos utiles Limpieza y mantenimiento Limpieza diaria Limpieza semanal Limpieza peri dica Cambio del filtr
51. s afficher sur I cran LCD 2 Copie des donn es sur la carte de donn es e La copie des donn es commence automatiquement une fois que la carte de donn es a t ins r e dans le module de carte de donn es Le message CARTE INSEREE Patientez SVP s affiche sur l cran LCD de la VPAP Auto pendant la copie des donn es La copie peut prendre jusqu 30 secondes Instructions d utilisation Frangais 21 22 Le message COPIE TERMINEE Retirez carte s affiche sur l cran LCD une fois que la copie est termin e e Retirez la carte de donn es du module de carte de donn es Aucune autre donn e n est copi e sur la carte une fois que le message COPIE TERMINEE Retirez carte s est affich m me si la carte est laiss e dans l appareil Pour ajouter d autres donn es la carte de donn es vous devez l ins rer une nouvelle fois et r p tez les op rations pr c dentes 3 Retrait de la carte de donn es Prenez la carte de donn es par le bout qui d passe et tirez pour la retirer du module de carte de donn es H 3 4 Rangement de la carte de donn es Votre carte de donn es doit tre conserv e dans son enveloppe de retour lorsqu elle n est pas utilis e 5 Envoi de la carte de donn es votre clinicien Proc dure suivre pour l envoi de la carte de donn es votre clinicien 1 Ins rez la carte de donn es dans la poche de l enveloppe de retour pr vue a cet effet Pliez l enveloppe de re
52. su unidad VPAP Auto Informaci n m dica Espafiol 3 Si le internan en un hospital o si le indican cualquier otra forma de tratamiento m dico informe siempre al personal m dico acerca de su tratamiento con PAP o binivel Tambi n es importante que se ponga en contacto con el m dico que le est tratando por su apnea del sue o Si sufre una infecci n sinusal de las vias respiratorias superiores o del o do medio p ngase en contacto con su m dico antes de continuar con el tratamiento PAP o binivel Es posible que le aconsejen que suspenda el tratamiento hasta que la infecci n haya sido curada Si sigue con el tratamiento durante una infecci n aseg rese de limpiar la mascarilla y el tubo despu s de cada uso Precauciones A bajas presiones el flujo de aire a trav s de los puertos de espiraci n de la mascarilla puede no ser suficiente para eliminar todos los gases espirados del tubo Puede darse cierto grado de reinspiraci n El flujo de aire generado por este equipo para la respiraci n puede llegar a estar hasta 6 C 11 F por encima de la temperatura ambiente Se deber tener cuidado si la temperatura ambiente es superior a los 32 C 90 F Cuando no haya disponibilidad de energ a de red CA de 100 240V utilice siempre un transformador DC 12 de ResMed El transformador DC 12 se puede obtener como accesorio opcional Si se suministra el m dulo Tarjeta de datos ResScan M est dise ado para ser usado con
53. texto gu a incluye men cambiar y aplicar Derecha e Realiza la funci n indicada por el texto guia que aparece justo encima de ella en el visor El texto gu a incluye salir y a cancelar Para ayudarle con el ajuste del VPAP Auto el teclado y el visor vienen equipados con una luz de fondo La luz de fondo del visor se enciende al iniciar la unidad o al oprimir una de las teclas y se apaga pasados dos minutos La luz de fondo del teclado permanece encendida mientras el VPAP Auto est encendido Uso de los men s La unidad VPAP Auto ofrece varias funciones que est n organizadas en men s y submenus A trav s del visor los men s y submenus le permiten ver y cambiar las configuraciones de una funci n en particular Usted puede acceder a los men s independientemente de si el VPAP Auto se encuentra en modo de espera o suministrando tratamiento Una vez que aparece la pantalla de bienvenida y el equipo haya terminado de realizar las autoverificaciones aparecer la pantalla de Rampa modo S y modo CPAP o la pantalla de Adaptaci n modo VAuto Pantalla de Rampa Modo S y modo CPAP Si se establece un tiempo de rampa m ximo aparece la pantalla de rampa despu s de la pantalla de bienvenida Una vez que est en la pantalla de rampa podr establecer un tiempo de rampa inmediatamente El tiempo de rampa es el periodo durante el cual se va incrementando la presi n a partir de una presi n baja hasta la presi n indicada para el
54. tratamiento Ver Tiempo de rampa en la p gina 17 El tiempo de rampa se puede modificar en incrementos de 5 minutos desde APAGADO hasta un tiempo de rampa m ximo fijado por su m dico mediante la tecla Retroceso Avance Pantalla de Adaptaci n modo VAuto Si el m dico configur un tiempo m ximo de adaptaci n la pantalla de adaptaci n aparece despu s de la pantalla de bienvenida En la pantalla de adaptaci n se puede establecer inmediatamente un tiempo de adaptaci n El tiempo de adaptaci n es el per odo durante el cual el equipo permanece en el valor de EPAP M n con una presi n inspiratoria determinada por la presi n de soporte adem s de la EPAP M n Ver Tiempo de adaptaci n en la p gina 17 El tiempo de adaptaci n se puede modificar en incrementos de 5 minutos desde APAGADO hasta un tiempo de adaptaci n m ximo fijado por su m dico mediante la tecla Retroceso Avance Menus El menu le permite ver informaci n sobre la versi n de software actual de su VPAP Auto y el tiempo de utilizaci n La pantalla de tiempo Usado muestra el numero total de horas durante las que se ha usado el dispositivo desde que el m dico lo puso en cero por ultima vez Tambi n muestra la cantidad de dias en que se uso el VPAP Auto con respecto al numero total de dias en que estuvo disponible para ser utilizado La pantalla VS muestra la versi n de software actual que esta instalada en el VPAP Auto Figura 2 resume
55. un sistema de mascarilla ResMed suministrado aparte Se recomiendan los siguientes sistemas de mascarillas ResMed para el uso con el VPAP Auto Mascarillas Nasales e Mascarilla Nasal Mirage Vista e Mascarilla Nasal Ultra Mirage e Mascarilla Nasal Ultra Mirage II e Mascarilla Nasal Mirage Activa M Sistemas de Almohadillas Nasales e Sistema de Almohadillas Nasales Mirage Swift Sistema de Almohadillas Nasales Mirage Swift II Mascarillas Faciales e Mascarilla Facial Mirage Liberty e Mascarilla Facial Mirage Quattro e Mascarilla Facial Ultra Mirage Notas No pueden obtenerse todas las mascarillas en todas las regiones Los dispositivos de ResMed han sido dise ados y fabricados para lograr un funcionamiento y rendimiento ptimos usando los sistemas de mascarillas con ventilaci n de ResMed Se pueden utilizar otros sistemas de mascarillas pero es posible que e funcionamiento y los resultados se vean afectados En el modo VAuto s lo las mascarillas ResMed son compatibles con el VPAP Auto Sistema VPAP Auto Espafiol El m dico necesita configurar su VPAP Auto para que lo use con su mascarilla en particular Humidificador Consulte la figura en la secci n B de la hoja de figuras Si experimenta sequedad de la nariz boca o garganta puede ser necesario utilizar un humidificador El VPAP Auto es compatible para ser usado con el humidificador t rmico HumidAire 3i B ADVERTENCI
56. y 800 MHz se aplica la distancia para el rango de frecuencias m s alto NOTA 2 es posible que estas gu as no se apliquen en todas las situaciones La propagaci n electromagn tica es afectada por la absorci n y el reflejo en estructuras objetos y personas Especificaciones t cnicas Espafiol 37 38 Garantia limitada ResMed garantiza que su producto ResMed estar libre de todo defecto de material y mano de obra durante el plazo estipulado a continuaci n a partir de la fecha de adquisici n por parte del consumidor inicial Esta garantia no es transferible Producto Plazo de la garantia Humidificadores ResMed ResControl ResLink 1 a o ResTraxx Generadores de aire ResMed 2 a os Accesorios sistemas de mascarilla incluye armaz n de la 90 d as mascarilla almohadilla arn s para la cabeza y tubos Excluye los dispositivos desechables Nota algunos modelos no se encuentran disponibles en todas las regiones Si el producto falla bajo condiciones de utilizaci n normales ResMed reparar o reemplazar a opci n suya el producto defectuoso o cualquiera de sus componentes Esta garant a limitada no cubre a cualquier da o causado como resultado de una utilizaci n indebida abuso modificaci n o alteraci n del producto b reparaciones llevadas a cabo por cualquier organizaci n de servicio que no haya sido expresamente autorizada por ResMed para efectuar dichas reparacione
57. you press a key and turns off after two minutes The keypad backlight is on at all times when the VPAP Auto is powered Using the Menus The VPAP Auto unit provides a set of functions which are arranged in menus and submenus Via the LCD screen the menus and submenus allow you to view and change the settings for a particular function You can access the menus regardless of whether the VPAP Auto is in standby mode or delivering therapy After the Welcome screen appears and device self checks are complete you will see either the Ramp screen S mode and CPAP mode or the Settling screen VAuto mode Ramp Screen S mode CPAP mode If your clinician has set a maximum ramp time the Ramp screen is displayed after the Welcome screen On the Ramp screen you can immediately set a ramp time Ramp time is the period during which the pressure increases from a low pressure to the prescribed treatment pressure See Ramp Time on page 16 Ramp time can be altered in five minute increments from OFF to a maximum ramp time set by your clinician by the using the Up Down key Settling Screen VAuto mode If your clinician has set a maximum settling time the Settling screen is displayed after the Welcome screen On the Settling screen you can immediately set a settling time Settling time is the period for which the device remains at Min EPAP with an inspiratory pressure determined by Pressure Support on top of Min EPAP See Settling Time
58. 80 MHz RF irradiada 10 V m 10 V m d 0 35 VT 80 MHz a 800 MHz IEC 61000 4 3 80 MHz a 2 5 GHz d 0 70 VT 800 MHz a 2 5 GHz onde T a tens o m xima de sa da do ransmissor em Watts W de acordo com o abricante do transmissor e d o afastamento recomendado em metros m A intensidade de campo proveniente de ransmissores de RF fixos determinada por uma inspe o eletromagn tica da instalac o dever ser menor que o n vel de conformidade para cada faixa de frequ ncia Poder o ocorrer interfer ncias em reas pr ximas a equipamentos marcados com o seguinte s mbolo o NOTA 1 a 80 MHz e 800 MHz aplic vel a maior faixa de frequ ncia NOTA 2 estas diretrizes podem n o ser aplic veis a todas as situa es A propaga o eletromagn tica afetada pela absor o e reflex o de estruturas objetos e pessoas a A intensidade de campo de transmissores fixos como por exemplo esta es base para telefones por ondas de r dio celulares sem fio e r dios m veis terrestres r dio amador transmiss es de radiodifus o AM e FM e televis o n o pode ser prevista com exatid o Para avaliar o ambiente eletromagn tico resultante de transmissores fixos de RF considere a realiza o de um levantamento eletromagn tico do local Se o valor da intensidade de campo no local onde o dispositivo VPAP Auto est em uso ultrapassar o n vel de conformidade de RF aplic vel mencionado acim
59. A S lo el HumidAire 3i es compatible con el VPAP Auto Consulte las advertencias de p gina 2 Accesorios Consulte las figuras en la secci n C de la hoja de figuras Se dispone de los siguientes accesorios para el uso con el VPAP Auto e Tarjeta de datos ResScan C 1 e M dulo Tarjeta de datos ResScan C 2 e M dulo en blanco C 3 Transformador DC 12 C 4 Tubo de aire de 3 m 9 pies 10 pulgadas C 5 Nota ResMed recomienda los siguientes productos de tubos para utilizar con el VPAP Auto tubo de aire de 3 m 9 pies 10 pulgadas gris NP 14980 tubo de aire de 2 m 6 pies 6 pulgadas gris NP 14948 tubo de aire desechable transparente PN 14912 Ox geno suplementario VPAP Auto est dise ado para ser compatible con el uso en tratamientos de ox geno de flujo bajo proporcionado a partir de una fuente externa A un caudal fijo de ox geno suplementario la concentraci n de ox geno inhalado variar seg n las configuraciones de presi n programadas el ritmo respiratorio del paciente la mascarilla elegida y el caudal de fuga Esta advertencia se aplica a la mayor a de los tipos de equipos PAP Preparacion para el uso Configuracion de VPAP Auto 1 Coloque el VPAP Auto sobre una mesa cerca de la cabecera de su cama PRECAUCION Tenga cuidado de no colocar el equipo en un lugar donde pueda ser golpeado o donde alguien pueda tropezar con el cable de alimentaci n Nota tambi n puede colocar
60. Accessoires Carte de donn es Dimensions L x x paisseur 2 56 x 0 87 x 0 03 65 04 mm x 22 15 mm x 0 85 mm Module de carte de donn es Dimensions Hx I x P 1 95 x 1 66 x 0 47 49 7 mm x 42 2 mm x 12 mm Remarque le fabricant se r serve le droit de modifier ces caract ristiques sans notification pr alable Caract ristiques 33 34 Symboles apparaissant sur l appareil N Attention veuillez consulter la documentation jointe Y Equipement de type CF quipement de classe II 4 Protection anti gouttes IPX 4 Tension potentiellement dangereuse C Marche Arr t et ajustement du masque Guide et d claration du fabricant Emissions et immunit lectromagn tiques Guide et d claration du fabricant Emissions lectromagn tiques La VPAP Auto est pr vue pour une utilisation dans l environnement lectromagn tique d crit ci dessous Le client ou l utilisateur de la VPAP Auto doit s assurer que celle ci est utilis e dans un environnement de ce type Essai de contr le des Pears Environnement ghia NE Compatibilit E gi missions lectromagn tique Guide Fran ais missions RF CISPR11 Groupe 1 La VPAP Auto utilise de l nergie RF uniquement pour son fonctionnement interne Par cons quent les missions RF sont tr s faibles et ne devraient pas causer d interf rences avec l quipement lectronique environnant Emissions RF CISPR 11
61. Agent 14040 Danielson Street Poway CA 92064 6857 USA ResMed UK Ltd EU Authorized Representative 96 Milton Park Abingdon Oxfordshire OX14 4RY UK ResMed Offices Australia Austria Brazil China Finland France Germany Hong Kong India Japan Malaysia Netherlands New Zealand Norway Singapore Spain Sweden Switzerland UK USA see www resmed com for contact details Protected by patents AU 691200 AU 697652 AU 699726 AU 702820 AU 709279 AU 713679 AU 724589 AU 764761 EP 0651971 EP 0661071 EP 0858352 EP 0920845 EP 0927538 EP 0934723 JP 3638613 US 5199424 US 5245995 US 5522382 US 5704345 US 6029665 US 6138675 US 6213119 US 6363933 US 6398739 US 6591834 US 6635021 US 6675797 US 6705315 US 6745768 US 6770037 US 6935337 US 7004908 US 7040317 Other patents pending Protected by design registrations AU 302180 AU 302181 AU 302182 AU 302183 AU 302184 AU 302185 AU 302186 CN 200430121212 2 CN 200430121211 8 CN 200430121214 1 CN 200430121215 6 CN 200430121216 0 CN 200430121217 5 EP 269436 HK 0412901 9 JP 1257662 JP 1257663 JP 1266956 JP 1266957 JP 1267270 JP 1267271 NZ 405614 NZ 406923 NZ 406924 Others pending HumidAire HumidAire 3i SmartStart AutoSet ResScan Ti Control Ultra Mirage VPAP Vista and VPAP Auto are trademarks of ResMed Ltd HumidAire SmartStart Vista AutoSet and VPAP are registered in U S Patent and Trademark Office 2008 ResMed Ltd 268122 5 08 10 RESMED VPAP Aut
62. Auto est sous tension La VPAP Auto est quip e d un des deux modules suivants l arri re un module vierge ou un module de carte de donn es ResScan Utilisation d un module vierge Veuillez vous r f rer aux figures de la section F de la fiche dillustrations Le module vierge sert de cache de protection pour votre VPAP Auto Vous aurez ventuellement besoin d enlever ou de fixer le module par exemple pour utiliser un autre module Pour retirer le module vierge enlevez le de l arri re de la VPAP Auto afin d acc der au port de communication de donn es F 1 Pour fixer le module vierge poussez le dans le port de communication de donn es jusqu ce qu il se verrouille en position F 2 Remarque pour prot ger le port de communication de donn es veillez ce qu un module soit fix l arri re de l appareil en permanence Utilisation d un module de carte de donn es ResScan Veuillez vous r f rer aux figures de la section G de la fiche dillustrations Le module de carte de donn es ResScan est un accessoire de la VPAP Auto Utilisez une carte de donn es ResScan avec le module de carte de donn es afin de collecter des donn es et de modifier les r glages de la VPAP Auto Le module et la carte permettent votre clinicien d acc der facilement aux donn es relatives a votre traitement et de mettre a jour les r glages de votre appareil sans que vous deviez quitter votre domicile Fixation du module Pour fixer
63. Caso seu m dico tenha enviado um cart o de dados com novas configura es para o dispositivo Como dispositivo no modo de espera RAMPA OU ACOMODA O introduza o cart o na ranhura do m dulo A atualiza o ser iniciada automaticamente A mensagem Cart o inserido Aguarde ser apresentada no visor LCD durante a atualiza o A atualiza o pode demorar at 30 segundos A mensagem Configura es atualizadas Remova o cart o ser apresentada no visor LCD caso as configura es tenham sido atualizadas corretamente Nota essa mensagem ser apresentada uma s vez Se voltar a introduzir o cart o de dados ap s a atualiza o das configura es essa mensagem n o ser apresentada e Remova o cart o de dados do m dulo e Guarde o cart o de dados no envelope de resposta postal quando n o estiver em uso Instru es operacionais Portugu s 21 AVISO Se o m dico tiver pedido que use esse cart o de dados para atualizar as configura es no seu dispositivo e a mensagem Configura es atualizadas Remova o cart o n o for apresentada contate o m dico imediatamente Dicas teis Para come ar Fugas de ar pela boca Se estiver usando uma m scara nasal tente manter a boca fechada durante o tratamento As fugas de ar pela boca podem diminuir a efic cia do tratamento Se as fugas de ar pela boca forem um problema experimente usar uma m scara facial ou uma correia pa
64. GHz donde P es la potencia maxima de salida del transmisor en vatios W seg n el fabricante del transmisor y d es la distancia de separaci n recomendada en metros m Las intensidades de campo de los transmisores de RF fijos seg n lo que determine la encuesta electromagn tica del lugar deben ser menores al nivel de cumplimiento en cada rango de frecuencia Puede haber interferencias cerca de equipos marcados con el siguiente s mbolo C b NOTA 1 a 80 MHz y 800 MHz se aplica el rango de frecuencias m s alto NOTA 2 es posible que estas gu as no se apliquen en todas las situaciones La propagaci n electromagn tica es afectada por la absorci n y el reflejo en estructuras objetos y personas a Las intensidades de campo de los transmisores fijos tales como estaciones base para tel fonos de radio celulares inalambricos y radios m viles terrestres radios amateur transmisores de radio AM y FM y de televisi n no se pueden predecir con exactitud en forma te rica Para evaluar el entorno electromagn tico provocado por transmisores de RF fijos se deber a considerar la posibilidad de realizar una encuesta electromagn tica del lugar Si la intensidad de campo medida en el lugar donde habr de usarse el equipo VPAP Auto excediera el nivel de cumplimiento de RF correspondiente indicado antes el equipo VPAP Auto deber a ser vigilado en cuanto a su normal funcionamiento Si ocurriera un funcionamiento anorm
65. Inspecione o filtro de ar todos os meses para verificar se est obstru do por sujeira ou tem perfura es Se o VPAP Auto for utilizado regularmente o filtro de ar dever ser substitu do a cada seis meses ou mais frequentemente se a unidade estiver em um ambiente empoeirado AVISO N o lave o filtro de ar O filtro de ar n o lav vel ou reutiliz vel Atampa do filtro de ar protege o dispositivo no caso de algum l quido ser acidentalmente derramando sobre o dispositivo Certifique se de que o filtro de ar e a tampa do filtro de ar estejam sempre instalados Manuten o PRECAU O N o tente abrir o gabinete do VPAP Auto N o existem pe as dentro do aparelho que possam ser reparadas pelo usu rio A inspe o e os consertos s devem ser realizados por t cnicos autorizados Em nenhuma circunst ncia tente efetuar consertos ou manuten o por conta pr pria Este produto VPAP Auto deve ser examinado por uma assist ncia t cnica autorizada da ResMed 5 anos ap s a data de fabrica o Antes disso o dispositivo dever proporcionar um funcionamento seguro e confi vel desde que utilizado e mantido segundo as instru es fornecidas pela ResMed Os detalhes da garantia ResMed aplic vel s o fornecidos com o dispositivo na compra original Como de h bito quando se trata de dispositivos el tricos em caso de alguma irregularidade aparente seja prudente e encaminhe o dispositivo para ser examinado por uma assist
66. PAP Auto est conforme aux r glements de la FCC USA Partie 15 normes applicables aux quipements de Classe B si aucun c ble de donn es externe n est utilis Remarque n utilisez pas votre VPAP Auto pendant le d collage ou l atterrissage Nettoyage et entretien Vous devez effectuer r guli rement le nettoyage et l entretien d crits dans cette section Veuillez vous r f rer au manuel du masque pour les instructions d taill es Nettoyage quotidien Masque Nettoyez le masque conform ment aux instructions fournies avec le masque Fran ais Circuit respiratoire D tachez le circuit respiratoire au niveau de la VPAP Auto et de l humidificateur le cas ch ant et suspendez le circuit respiratoire et le masque dans un endroit propre et sec jusqu la prochaine utilisation Humidificateur Si vous utilisez un humidificateur nettoyez le conform ment a son mode d emploi Nettoyage hebdomadaire 1 D tachez le circuit respiratoire de la VPAP Auto et du masque 2 Lavez le circuit respiratoire l eau ti de avec un d tergent doux Rincez soigneusement et suspendez le pour le faire s cher 8 Avant de les r utiliser assemblez le masque et le harnais conform ment au mode d emploi 4 Raccordez le circuit respiratoire la sortie d air et au masque Nettoyage p riodique 1 Nettoyez l ext rieur de la VPAP Auto l aide d un chiffon humide et de savon liquide doux 2 V rifiez que le filtre air n est
67. RESMED VPAP Auto POSITIVE AIRWAY PRESSURE DEVICE User Guide English Frangais Espa ol Portugu s 268122 5 08 10 VPAP Auto User 2 6 8 1 2 2 Global leaders in sleep and respiratory medicine www resmed com RESMED INTEGRATED HUMIDIFIER HUMIDIFICATEUR INT GR HUMIDIFICADOR INTEGRADO UMIDIFICADOR INTEGRADO VPAP Auto Component of 268122 5 Partie de 268122 5 Componente de 268122 5 Componente de 268122 5 ILLUSTRATIONS ILLUSTRATIONS FIGURAS ILUSTRA ES A SYSTEM COMPONENTS COMPOSANTS DU SYSTEME COMPONENTES DEL SISTEMA COMPONENTES DO SISTEMA paid Carry handle Poign e de transport Asa para el transporte Al a de transporte LCD screen cran LCD Visor LCD Visor LCD Module Module M dulo M dulo DC input Entr e CC Entrada de CC Entrada CC Note Some products not available in all regions Remarque certains de ces produits ne sont pas disponibles dans tous les pays Nota algunos productos no est n disponibles en todas las regiones Nota alguns produtos n o se encontram dispon veis em todas as regi es Keypad Clavier Teclado Teclado OTHER ACCESSORIES AUTRES ACCESSOIRES OTROS ACCESORIOS OUTROS ACESS RIOS Air outlet Sortie d air Salida de aire Sa da de ar Air filter cover Couvercle du logement du filtre air Cubierta del filtro de aire Tampa do filtro de ar Air inlet Entr e d air
68. a es a estas especifica es sem aviso pr vio Simbolos apresentados no dispositivo Aten o consulte os documentos associados Y Equipamento do tipo CF Equipamento de Classe II 4 A prova de respingos IPX2 4 Tens o perigosa C Iniciar Parar e ajuste da m scara Especifica es t cnicas Portugu s 33 34 Guia e Declara o do Fabricante Imunidade e Emiss es Eletromagn ticas Guia e declara o do fabricante Emiss es eletromagn ticas O VPAP Auto deve ser utilizado no ambiente eletromagn tico especificado abaixo O cliente ou o usu rio do VPAP Auto deve se certificar de que o sistema ser utilizado somente neste ambiente Teste de emiss es Conformidade Ambiente eletromagn tico orienta o Emiss es de RF Grupo 1 O dispositivo VPAP Auto usa energia radiofrequ ncia CISPR11 de radiofrequ ncia apenas para seu funcionamento interno Por essa raz o as emiss es de RF s o muito baixas e pouco prov vel que provoquem interfer ncias em equipamentos eletr nicos pr ximos Emiss es de RF CISPR 11 com Classe B O dispositivo VPAP Auto adequado adaptador serial para utiliza o em todos os locais incluindo resid ncias e locais ligados Emiss es de RF CISPR 11 com Classe B diretamente rede p blica de baixa adaptador USB tens o que gera energia para fins dom sticos Emiss es harm nicas Classe A IEC 61000 3 2 Flutua e
69. a verifique se o dispositivo funciona normalmente Se for observado um desempenho anormal poder ser necess rio tomar medidas adicionais como redirecionar ou alterar a posi o do dispositivo b Na faixa de frequ ncia entre 150 kHz e 80 MHz a intensidade de campo dever ser inferior a 10 V m Afastamentos recomendados entre equipamentos de comunica o de RF port teis e m veis e os dispositivos da s rie VPAP Auto O VPAP Auto deve ser utilizado em um ambiente onde as perturba es de RF irradiadas sejam controladas O cliente ou usu rio do dispositivo VPAP Auto pode ajudar a evitar interfer ncias eletromagn ticas mantendo a dist ncia m nima entre os equipamentos de comunica o de RF port teis e m veis transmissores e o dispositivo VPAP Auto como recomendado abaixo de acordo com a pot ncia m xima de sa da do equipamento de comunica o Afastamento de acordo com a frequ ncia do transmissor m Pot ncia m xima 150 kHz a 80 MHz 80 MHz a 800 MHz 800 MHz a 2 5 GHz nominal de sa da do transmissor d 1 17 VT d 0 35 VT d 0 7 VT W 0 01 0 17 0 04 0 07 0 1 0 37 0 11 0 22 1 1 17 0 35 0 7 10 3 69 1 11 2 21 100 11 70 3 50 70 Para transmissores com pot ncia m xima nominal de sa da n o listada acima o afastamento d recomendado em metros m pode ser determinado atrav s da equa o aplic vel a frequ ncia do transmissor onde T a tens o m xima nominal de sa
70. ada e est gerando fuga excessiva O tubo de ar est dobrado ou foi perfurado Evite falar quando estiver usando uma m scara nasal e respire de maneira normal Ajuste o arn s Ajuste o arn s ou volte a posicionar a almofada Endireite ou substitua o tubo Resolu o de problemas Portugu s 21 28 Problema Possivel causa O bot o de controle do umidificador foi ajustado para um valor muito alto resultando em ac mulo de gua no interior do tubo Solu o Reduza a intensidade do umidificador e escorra a gua do tubo de ar O tubo de ar est solto ou obstru do Mensagem de erro Verificar tubo Reiniciar quando feito Verifique se o tubo de ar est firmemente conectado m scara e sa da de ar na parte da frente do VPAP Auto Quando tiver verificado o tubo de ar pressione a tecla Iniciar Parar para reiniciar o aparelho Se isso n o limpar a mensagem desconecte o cabo de energia e em seguida volte a conect lo para reiniciar o dispositivo Mensagem de erro ERRO SISTnnnn Contate a assist ncia t cnica Falha de componente Registre o n mero do erro e entre em contato com o centro de apoio da ResMed Mensagem de erro Voc est com n veis FUGA demasiadamente altos de fugas EXCESSIVA por mais de 20 segundos Ajustar m scara Verifique se o tubo de ar est conectado de forma adequada e se a m scara n o cont m fugas excessivas Use o re
71. ada neste manual Nota os avisos e precau es acima s o de cunho geral Avisos precau es e notas espec ficas aparecer o junto s instru es relevantes no manual Efeitos adversos Caso venham a sentir dores tor cicas incomuns dores de cabe a fortes ou maiores dificuldades de respira o os pacientes devem contatar o m dico que prescreveu a terapia e relatar o ocorrido Uma infec o aguda no trato respirat rio superior poder exigir a interrup o tempor ria do tratamento Os seguintes efeitos colaterais podem ocorrer durante o tratamento com o dispositivo ressecamento do nariz boca ou garganta sangramento nasal incha o mal estar no ouvido ou seio nasal irrita o dos olhos urtic ria desconforto no peito O Sistema VPAP Auto Consulte as ilustra es na sec o A do folheto de ilustra es Vista frontal A 1 Mostra o teclado o visor LCD e a sa da de ar Vista de tr s A 2 Mostra o ponto de conex o do m dulo e a localiza o do filtro de ar e das tomadas de energia Cabo de energia A 3 Cabo de energia para conectar o VPAP Auto tomada de energia CA rede el trica Bolsa de transporte A 4 Tubo de ar A 5 O tubo de ar de 2 m 78 pol conecta o VPAP Auto m scara M scara Voc tamb m precisar de um sistema de m scara ResMed fornecido separadamente Os seguintes sistemas de m scaras ResMed s o recomendados para utiliza o com o VPAP Auto M scaras Nasais
72. agn tica EMC de acordo com o IEC 60601 1 2 para reas residenciais comerciais e de ind stria leve Para mais informa es consulte Guia e Declara o do Fabricante Imunidade e Emiss es Eletromagn ticas na p gina 34 Especifica es t cnicas Portugu s 31 Nivel de ruido Modo VPAP Auto CPAP 10 cm H 0 press o fixa N vel de press o ac stica total medido em A 24 dBA dB re 20 uPa Imprecis o dB re 20 uPa 2 dBA Os valores medidos s o determinados de acordo com o procedimento de teste de ru do indicado em ISO 17510 1 Nota a soma do valor de emiss o de ru do medido com sua imprecis o associada representa o limite superior da faixa de valores que costumam ocorrer em medi es a Valores de emiss o de ru do de dois d gitos declarados em conformidade com ISO 4871 Filtro de ar duas camadas de fibra n o tecida de poli ster coligadas por p Tubo de ar pl stico flex vel 2 m 78 pol de comprimento Sa da de ar a sa da de ar c nica de 22 mm encontra se em conformidade com EN 1281 1 Classifica o IEC 60601 1 classe isolamento duplo tipo CF Nota o fabricante se reserva o direito de fazer altera es a estas especifica es sem aviso pr vio Acess rios Cart o de dados Dimens es C x L x P 65 04 mm x 22 15 mm x 0 85 mm M dulo de cart es de dados Dimens es A x L x P 49 7 mm x 42 2 mm x 12 mm Nota o fabricante se reserva o direito de fazer alter
73. agnetic immunity The VPAP Auto device is intended for use in tl customer or the user of the VPAP Auto devic environment he electromagnetic environment specified below The e should assure that the device is used in such an Immunity test 1EC60601 1 2 test level Compliance level Electromagnetic environment guidance Electrostatic discharge ESD 6 kV contact 6 kV contact Floors should be wood concrete or ceramic tile If IEC 61000 4 2 8 kV air 8 KV air floors are covered with synthetic material the relative humidity should be at least 30 Electrical fast 2 kV for power 2 kV Mains power quality should transient burst supply lines be that of a typical IEC 61000 4 4 commercial or hospital 1 kV for input Not Applicable environment output lines Surge 1 kV differential 1 kV differential Mains power quality should IEC 61000 4 5 mode mode be that of a typical 2 kV common mode 2 kV common mode commercial or hospital environment Voltage dips short lt 5 U lt 12V Mains power quality should interruptions and gt 95 dip in Ut gt 95 dip in 240V be that of a typical voltage variations on or 0 5 cycle or 0 5 cycle commercial or hospital power supply input environment lines 40 U 96 V If the user of the VPAP IEC 61000 4 11 60 dip in Ut 60 dip in 240V Auto device requires or 5 cycles or 5 cycles continued operation during power mains inte
74. aire du traitement Les effets secondaires suivants peuvent appara tre au cours du traitement sous VPAP Auto s cheresse nasale buccale ou de la gorge saignements de nez ballonnements g ne au niveau de l oreille ou des sinus irritation des yeux ryth mes cutan s g ne au niveau de la poitrine Le systeme VPAP Auto Veuillez vous r f rer aux figures de la section A de la fiche dillustrations Vue avant A 1 Repr sente le clavier et l cran LCD ainsi que la sortie d air Vue arri re A 2 Indique le point de fixation du module et l emplacement du filtre air et des prises d alimentation Cable d alimentation A 3 C ble d alimentation pour brancher la VPAP Auto l alimentation secteur CA Sac de transport A 4 Circuit respiratoire A 5 Le circuit respiratoire de 6 6 2 m permet de raccorder la VPAP Auto votre masque Masque Vous aurez galement besoin d un masque ResMed fourni s par ment Les masques ResMed suivants sont recommand s pour utilisation avec la VPAP Auto Masques nasaux e Masque nasal Mirage Vista e Masque nasal Ultra Mirage e Masque nasal Ultra Mirage Il e Masque nasal Mirage Activa Masques narinaires e Masque narinaire Mirage Swift e Masque narinaire Mirage Swift II Masques faciaux e Masque facial Mirage Liberty Masque facial Mirage Quattro Masque facial Ultra Mirage Remarques Certains de ces masques n
75. al pueden ser necesarias medidas adicionales como la reorientaci n o reubicaci n del equipo VPAP Auto b Por encima del rango de frecuencias de 150 kHz a 80 MHz las intensidades de campo deberian ser menores a 10 V m Distancias recomendadas entre equipos de comunicacion por RF portatiles y moviles y la serie de equipos VPAP Auto El equipo VPAP Auto esta dise ado para ser usado en un entorno en el que sean controladas las alteraciones por RF irradiada El cliente o usuario del equipo VPAP Auto puede ayudar a prevenir la interferencia electromagn tica guardando una distancia m nima entre los equipos de comunicaciones por RF port tiles y m viles transmisores y el equipo VPAP Auto tal como se recomienda a continuaci n seg n la potencia m xima de salida del equipo de comunicaciones Distancia seg n la frecuencia del transmisor m Potencia m xima de De 150 kHz a 80 MHz 80 MHz a 800 MHz 800 MHz a 2 5 GHz salida del transmisor Ww d 1 17 VP d 0 35 VP d 0 7 VP 0 01 0 17 0 04 0 07 0 1 0 37 0 11 0 22 1 1 17 0 35 0 7 10 3 69 1 11 2 21 100 11 70 3 50 7 0 Para transmisores con una potencia maxima de salida que no figure en la tabla precedente la distancia recomendada d en metros m se puede determinar por medio de la ecuaci n que se aplica a la frecuencia del transmisor donde P es la potencia m xima de salida del transmisor en vatios W seg n el fabricante del transmisor NOTA 1 a 80 MHz
76. amente O cart o n o um cart o de dados ResScan Voc pode ter removido o cart o antes dos dados terem sido copiados Certifique se de introduzir o cart o de dados com a seta virada para cima e apontando para o dispositivo Use um cart o de dados ResScan tal como especificado neste manual Volte a introduzir o cart o e espere at que a mensagem C pia conclu da Remova o cart o seja apresentada no visor LCD A mensagem a seguir apresentada no visor LCD depois que voc tenta atualizar as configura es usando o cart o de dados Configura es inv lidas Remova o cart o Os detalhes de identifica o no cart o de dados n o correspondem aos detalhes no seu dispositivo Entre imediatamente em contato com seu m dico Resolu o de problemas Portugu s 29 30 Problema A mensagem a seguir apresentada no visor LCD depois que voc tenta atualizar as configura es usando o cart o de dados Erro de configura o Remova o cart o Poss vel causa Existe um erro de dados no cart o de dados Solu o Entre imediatamente em contato com seu m dico A mensagem a seguir N O apresentada no visor LCD depois que voc tenta atualizar as configura es usando o cart o de dados Configura es atualizadas Remova o cart o As configura es n o foram atualizadas Entre imediatamente em contato com seu m dico Especifica es t cni
77. ares PRECAUCI N S LO EE UU La ley federal estipula que este aparato solamente puede ser vendido por un m dico o por su indicaci n Contraindicaciones El tratamiento con presi n positiva en las v as respiratorias puede estar contraindicado en algunos pacientes que presenten las siguientes afecciones previas enfermedad pulmonar bullosa severa neumot rax presi n arterial patol gicamente baja deshidrataci n fuga de l quido cefalorraqu deo cirug a o traumatismo craneanos recientes Advertencias Se debe leer todo el manual antes de usar el VPAP Auto Los consejos que se dan en este manual no deben sustituir las instrucciones dadas por el m dico tratante El paciente no debe conectar ning n dispositivo en el puerto de comunicaci n de datos a menos que su m dico o proveedor de asistencia sanitaria se lo indique nicamente los productos ResMed han sido dise ados para ser conectados al puerto de comunicaci n de datos La conexi n de otros equipos puede provocar lesiones o da os al equipo VPAP Auto VPAP Auto debe utilizarse nicamente con las mascarillas y conectores recomendados por ResMed o por un m dico o terapeuta respiratorio No se coloque una mascarilla a menos que el equipo VPAP Auto est encendido y funcionando correctamente Nunca se debe obstruir el o los orificios de ventilaci n asociados con la mascarilla Explicaci n el equipo VPAP Auto se ha dise ado para utilizarse con
78. arte trasera de su VPAP Auto hasta que se ajuste en su lugar por medio de un clic G 1 Desconexi n del M dulo Para quitar el m dulo Tarjeta de datos t relo para separarlo de la parte trasera del VPAP Auto G 2 Nota para proteger el puerto de comunicaci n de datos verifique que en todo momento haya un m dulo acoplado en la parte trasera del equipo Uso de la Tarjeta de datos para recolectar datos Consulte las figuras en la secci n H de la hoja de figuras Si su m dico necesita examinar su tratamiento le pedir que use la Tarjeta de datos a efectos de copiar datos desde su VPAP Auto y que luego le envie la tarjeta La Tarjeta de datos se suministra en un pr ctico sobre de retorno postal Los datos se copian en la Tarjeta de datos cuando est insertada en el equipo Los datos originales permanecer n almacenados en el equipo El copiado de datos a la Tarjeta de datos tarda hasta un m ximo de 30 segundos 1 Inserte la Tarjeta de datos Encienda el VPAP Auto y espere hasta que vea la pantalla de espera RAMPA o ADAPTACION Tome en su mano la Tarjeta de datos de manera que la flecha apunte hacia arriba e ins rtela en la ranura del m dulo Tarjeta de datos H 1 e Empuje suavemente la tarjeta hacia dentro hasta que no avance m s H 2 y hasta que empiecen a aparecer mensajes en el visor 2 Copie los datos en la Tarjeta de datos Cuando la Tarjeta de datos se inserta en el m dulo Tarjeta de datos el copiado de los dato
79. artir de la pantalla de RAMPA o la de ADAPTACION Cuando el equipo est en el modo VAuto la presi n de ajuste de mascarilla es de 10 cm H 0 Cuando el equipo est en el modo CPAP la presi n de ajuste de mascarilla ser la presi n fija de tratamiento o bien 10 cm H30 la que sea mayor Cuando el equipo est en el modo S la presi n de ajuste de mascarilla ser EPAR o bien 10 cm H30 la que sea mayor e Las funciones de Alerta de fuga y SmartStop se desactivan mientras se usa el Ajuste de mascarilla Aj stese la mascarilla la almohadilla de la mascarilla y el arn s hasta conseguir un ajuste estable y c modo Una vez que cuente con un ajuste estable y c modo verifique su calificaci n de estrellas del ajuste de mascarilla en el visor Tabla 2 explica la calificaci n de estrellas del ajuste de mascarilla Nota si hay otra persona cerca que pueda observar su calificaci n de estrellas del ajuste de mascarilla usted podr ajustar su mascarilla almohadilla y arn s estando acostado a Tabla 2 Definiciones de la calificaci n de estrellas del ajuste de mascarilla Calificaci n de estrellas Definici n RENTE Excelente REE uy bueno ueno justar mascarilla B A Ajustar mascarilla A justar mascarilla 4 Despu s de 3 minutos la presi n bajar al m nimo preestablecido y se iniciar el tratamiento Sino quisiera esperar tres minutos oprima y mantenga presionada la tecla Inicio Detenci
80. ask selection and the leak rate This warning applies to most types of PAP machines Preparing for Use Setting Up the VPAP Auto 1 Place the VPAP Auto on a table near the head of your bed CAUTION Be careful not to place the device where it can be bumped or where someone is likely to trip over the power cord Note You can also place your VPAP Auto on the floor beside or underneath your bed Ensure that the area is free from dust and clear of bedding clothes or any other objects that could block the air inlet Connect the power cord to the socket at the rear of the flow generator D 1 Plug the other end of the power cord into the power outlet WARNING Make sure the power cord and plug are in good condition and the equipment is not damaged Connect one end of the air tubing firmly onto the air outlet D 2 WARNING Only ResMed air tubing should be used with your flow generator A different type of air tubing may alter the pressure you actually receive reducing the effectiveness of your treatment Blocking the air inlet or tubing while in operation could lead to overheating of the device e Inthe clinical environment any personal computer that is used with your CPAP system must be at least 5 1 5 m away from or at least 8 2 5 m above the patient It must also comply with the relevant test standard For personal computers the international standard is IEC 60950 or equivalent Assemble the Mask Assemble y
81. ation d clench e la fin de la dur e d inspiration minimale TiMx expiration d clench e la fin de la dur e d inspiration maximale C expiration d clench e spontan ment dans les limites de TiMin et TiMax Dur e de rampe Mode S mode CPAP La fonction Rampe dur e peut tre activ e par votre clinicien Si vous prouvez des difficult s vous endormir la pression maximum s lectionnez une dur e de rampe Le d bit d air d marre lentement pendant que vous vous endormez La pression augmente progressivement jusqu la pression de fonctionnement sur la dur e de rampe s lectionn e Le clinicien a d fini une dur e de rampe maximale vous pouvez s lectionner toute valeur jusqu au maximum Temps d attente Mode VAuto Le temps d attente est une fonction que votre clinicien peut activer Si vous prouvez des difficult s vous endormir lorsque la VPAP Auto est en mode de fonctionnement s lectionnez un temps d attente Le d bit reste la pression minimale pendant la dur e que vous avez r gl e vous donnant le temps de vous endormir Une fois cette dur e coul e la VPAP Auto est en mesure d augmenter la pression en r ponse aux v nements Le clinicien d finit un temps d attente maximal vous pouvez s lectionner toute valeur jusqu au maximum Pour s lectionner le type de masque Faites d filer les options jusqu l affichage de MASQUE puis s lectionnez Changer touche de gauche Appuyez sur la t
82. ations 33 34 Recommended separation distances between portable and mobile RF communications equipment and the VPAP Auto series of devices The VPAP Auto device is intended for use in an environment in which radiated RF disturbances are controlled The customer or the user of the VPAP Auto device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the VPAP Auto device as recommended below according to the maximum output power of the communications equipment Separation distance according to frequency of transmitter m Rated maximum output power of transmitter 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz Ww d 1 17 VP d 0 35 VP d 0 7 VP 0 01 0 17 0 04 0 07 0 1 0 37 0 11 0 22 1 1 17 0 35 0 7 10 3 69 1 11 2 21 100 11 70 3 50 70 For transmitters rated at a din metres m can be de maximum output power no ermined using the equation P is the maximum output power rating of the transmi manufacturer NOTE 1 At 80 MHz and 800 MHz the separation dis t listed above the recommended separation distance applicable to the frequency of the transmitter where tter in watts VV according to the transmitter ance for the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflecti
83. avec Classe B La VPAP Auto peut tre utilis e dans adaptateur s rie tous les tablissements y compris les tablissements domestiques et ceux Emissions RF CISPR 11 avec Classe B directement raccord s au r seau adaptateur USB public de distribution basse tension qui fournit de l lectricit aux Rayonnements harmoniques Classe A b timents utilis s des fins CEI 61000 3 2 domestiques missions dues aux fluctuations Conforme de tension au papillotement CEI 61000 3 3 Classe B pour toutes les configurations sauf lorsqu un ResLink avec oxym tre est connect la VPAP Auto fonctionnant sur un adaptateur secteur DC 12 auquel cas le syst me est conforme la Classe A Les quipements de Classe A peuvent tre utilis s dans tous les tablissements autres que les tablissements domestiques et ceux directement raccord s au r seau public de distribution basse tension qui fournit de l lectricit aux b timents utilis s des fins domestiques Des pr cautions particuli res doivent tre prises avec l quipement lectrique m dical quant la compatibilit lectromagn tique et son installation et sa mise en service doivent tre effectu es conform ment aux informations sur la compatibilit lectromagn tique fournies dans ce document Avertissements la VPAP Auto ne doit pas tre utilis e proximit d autres quipements ni pos e sur ou sous d autres quipements S l est impossible
84. blems trying to get a comfortable mask fit contact your sleep clinic or equipment supplier You may benefit from a different mask size You can also use the Mask Fitting feature to help you fit your mask properly See Using the Mask Fitting Feature on page 13 Before wearing your mask wash your face to remove excess facial oils This will allow a better fit and prolong the life of the mask cushion Nasal Irritation Dryness You may experience dryness of the nose mouth and or throat during the course of treatment especially during winter In many cases a humidifier may resolve this discomfort Contact your clinician for advice Runny or Blocked Nose You may experience sneezing and or a runny or blocked nose during the first few weeks of treatment In many cases nasal irritation can be resolved with a humidifier Consult your clinican for advice Use with DC Power You must use a ResMed DC 12 converter to connect the VPAP Auto to a 12 V or 24 V DC power source Contact your equipment supplier or ResMed for details WARNING The device should not be connected to both AC and DC power sources simultaneously Traveling with the VPAP Auto International Use Your VPAP Auto flow generator has an internal power adapter that enables it to operate in other countries It will operate on power supplies of 100 240V and 50 60Hz No special adjustment is necessary but you may need a plug adapter for the region for which you are using th
85. c tenha tempo de dormir Ap s esse per odo o VPAP Auto poder aumentar a press o em resposta a eventos O m dico definir um tempo de acomoda o m ximo Voc pode selecionar um valor qualquer at esse m ximo Como selecionar o tipo de m scara Navegue at M SCARA e selecione Alterar tecla Esquerda Pressione a tecla Para cima ou Para baixo at que apare a o tipo de m scara desejado A tabela a seguir apresenta a configura o a ser selecionada para cada tipo de m scara Instru es operacionais Portugu s Tabela 3 Configura es para tipos de m scaras Configura es M scara ULTRA M scara Nasal Ultra Mirage M scara Nasal Ultra Mirage Il MIR FACIAL M scara Facial Mirage Liberty M scara Facial Mirage Quattro M scara Facial Ultra Mirage ACTIVA M scara nasal Mirage Activa SWIFT Sistema de Almofadas Nasais Mirage Swift Sistema de Almofadas Nasais Mirage Swift II STANDARD M scara Nasal Mirage Vista Mensagens apresentadas no visor LCD do VPAP Auto Seu m dico pode ter programado o VPAP Auto para lembr lo de eventos importantes como por exemplo substituir a m scara introduzir o cart o de dados no caso do dispositivo utilizar cart o de dados entre outros O lembrete exibido no visor LCD e ficar visivel se o dispositivo nao estiver administrando uma terapia A luz de fundo do visor LCD pisca quando uma mensagem apresentada Seu m dico pode programar os seguinte
86. cardiaque s affichent en premier Si le traitement n a pas commenc l un des crans suivants s affiche sur la VPAP Auto qu un humidificateur soit en place ou non Avant le d but du traitement SpO2 98 RAMPE 20min 98 ATTENT 20min 98 menu RC 60 menu Y RC 60 menu t RC 60 Rampe Max d sactiv e Rampe Max r gl e sur Att Max r gl e sur une ou valeur autre que z ro valeur autre que z ro Att Max d sactiv e Figure 4 crans avec un ResLink et un oxym tre Acc s aux menus Pour naviguer et faire des s lections dans le menu Patient utilisez la touche de d placement vers le haut ou de d placement vers le bas pour faire d filer les options d un m me niveau la touche de gauche pour acc der un sous menu ou appliquer la s lection d une option la touche de droite pour sortir d un menu ou d un sous menu et pour quitter sans changer les options Saturation en oxyg ne SpO saturation de l h moglobine en oxyg ne en Fr quence rythme cardiaque RC nombre de battements de c ur par 60 secondes en battements par minute Pr paration avant l utilisation Fran ais Instructions d utilisation D but du traitement Ace stade la VPAP Auto devrait tre install e c t de votre lit et raccord e au circuit respiratoire et au masque Voir Installation de la VPAP Auto page 7 1 Branchez le cable d alimentation la source d alimentation Un message de bienvenue s affiche
87. cas Desempenho Faixa de press o operacional 3 a 20 cm H 0 Press o m xima de falha nica 30 cm H20 Toler ncia da medi o de press o 0 5 cm H20 4 da leitura medida Toler ncia da medi o de fluxo 0 1 ou 20 da leitura o que for maior Caracter sticas de press o din mica Modo VAuto 4 a 20 cm H20 medido na m scara press o de EPAP min 4 cm H20 press o de IPAP max 20 cm H20 Suporte de press o O a 10 cm H 0 Modo S IPAP 5 a 20 cm H20 medido na m scara EPAP 3 a 20 cm H20 medido na mascara Modo CPAP 4 a 20 cm H20 medido na m scara N vel de press o ac stica a press o ac stica emitida medida a lt 30 dBA em 10 cm H 0 e 1 m conforme 15017510 Dimens es CxLx A 112 mm x 164 mm x 145 mm 4 4 pol x 6 5 pol x 5 7 pol Peso 1 3 kg 2 9 lb Fornecimento de energia Faixa de entrada 100 240V 50 60Hz 40VA consumo de energia t pico lt 100VA consumo de energia m ximo Constitui o do gabinete termopl stico de engenharia retardador de chamas Condi es ambientais Temperatura operacional 5 C a 35 C 41 F a 95 F Umidade operacional 10 a 95 sem condensa o Temperatura de transporte e armazenamento 20 C a 60 C 4 F a 140 F Umidade de transporte e armazenamento 10 a 95 sem condensa o Altitude operacional n vel do mar a 2591 m 8500 p s Compatibilidade eletromagn tica O produto encontra se em conformidade com todos os requisitos de compatibilidade eletrom
88. cc der la fonction d ajustement du masque et commencer arr ter le traitement Les fonctions des touches et des combinaisons de touches de s lection rapide sont indiqu es dans e Tableau 1 Le r tro clairage de I cran LCD s teint au bout de deux minutes d inactivit se rallume lorsque vous appuyez sur une touche Pr paration avant l utilisation 9 Frangais 10 Tableau 1 Touches du panneau avant et leurs fonctions Touche Fonction Ecran LCD e Permet d afficher les informations de la VPAP Auto y compris les menus et les crans de traitement Permet de d marrer ou d arr ter le traitement Marche Arr t e En maintenant cette touche enfonc e pendant au moins ewes as trois secondes on active la fonction d ajustement du masque D placement vers e Permet de naviguer dans les menus et les sous menus de le haut la VPAP Auto et d augmenter les valeurs de r glage D placement vers e Permet de naviguer dans les menus et les sous menus de le bas la VPAP Auto et de r duire les valeurs de r glage e Permet d ex cuter la fonction indiqu e par le texte Gauche d explication affich sur l cran LCD au dessus de cette touche Le texte d explication comprend les l ments suivants menu changer et appliquer i e Permet d ex cuter la fonction indiqu e par le texte d explication affich sur l cran LCD au dessus de cette touche Le texte d explication comprend les l m
89. ceptar el mensaje tambi n desaparecer CAMBIAR Aparece cuandoes Oprima la tecla Izquierda Aceptar para que MASCARILLA tiempo de cambiar desaparezca el mensaje del visor y sustituya su mascarilla la mascarilla por una nueva 18 Mensaje Descripci n Acci n LLAMAR Aparece como Oprima la tecla Izquierda Aceptar para que PROVEEDOR recordatorio para desaparezca el mensaje del visor y ponerse en comun quese con su m dico contacto con su m dico por ejemplo para hablar sobre la marcha del tratamiento CAMBIAR Aparece como Oprima la tecla Izquierda Aceptar para que FILTRO recordatorio para desaparezca el mensaje del visor y sustituya cambiar el filtro de el filtro de aire aire de su equipo REALIZAR Aparece como Oprima la tecla Izquierda Aceptar para que SERVICIO recordatorio para desaparezca el mensaje del visor que envie el equipo a fin de que se le realice un servicio de mantenimiento Mensajes Es posible que su Oprima la tecla Izquierda Aceptar para que personalizados m dico tambi n configure recordatorios por otros motivos por ejemplo para devolver el equipo o para llamar a una persona o un n mero determinado desaparezca el mensaje del visor M dulos Nota no separe ning n m dulo mientras el VPAP Auto est conectado a la fuente de alimentaci n Su VPAP Auto tendr instalado en su parte trasera uno de los siguientes dos m dulos un m dulo en blanco o un m dulo de Ta
90. correr os v rios menus acessar o recurso de ajuste da m scara e iniciar parar o tratamento As fun es das teclas e as combina es de teclas r pidas s o listadas na Tabela 1 A luz de fundo do visor LCD desliga se automaticamente ap s dois minutos de inatividade E volta a ligar quando uma tecla pressionada Tabela 1 Teclas do painel frontal e as suas fun es Tecla Fun o Visor LCD e Apresenta informa es acerca do VPAP Auto incluindo os C menus e as telas de tratamento Iniciar Parar e Inicia ou p ra o tratamento Se voc mantiver a tecla pressionada por pelo menos 3 segundos o recurso de ajuste da m scara ser iniciado START STOP Mask fit Para cima e Permite percorrer os menus e submenus do VPAP Auto e aumentar as op es de configura o Para baixo e Permite percorrer os menus e submenus do VPAP Auto e aumentar as op es de configura o Prepara o para uso Portugu s 10 Tecla Fun o Esquerda e Desempenha a fun o indicada pelo texto informativo logo E acima no visor LCD O texto informativo inclui menu alterar e aplicar Direita e Desempenha a fun o indicada pelo texto informativo logo acima no visor LCD O texto informativo inclui sair e cancelar Para auxiliar no ajuste do VPAP Auto o teclado e o visor LCD foram equipados com uma luz de fundo A luz de fundo do visor LCD acende quando a unidade ligada ou quando uma tecla pressionada e d
91. curso de ajuste da m scara para colocar a m scara adequadamente Se o problema persistir entre em contato com seu m dico Mensagem de erro Exxxx onde xxxx representa um c digo de erro Falha de componente Envie a unidade VPAP Auto para manutenc o O cart o de dados n o foi introduzido corretamente A mensagem seguinte apresentada no visor LCD depois que voc tenta atualizar as configura es usando o cart o de dados Erro de cart o Remova o cart o Certifique se de introduzir o cart o de dados com a seta virada para cima e apontando para o dispositivo Certifique se de que o dispositivo se encontra ligado e no modo de espera antes de introduzir o cart o de dados Problema Possivel causa O cart o de dados s foi introduzido parcialmente Voc pode ter removido o cart o de dados antes das configura es terem sido copiadas para o VPAP Auto O cart o n o um cart o de dados ResScan Solu o Certifique se de que o cart o de dados foi inserido na ranhura do m dulo at o final Volte a introduzir o cart o de dados e espere at que a mensagem Configura es atualizadas Remova o cart o seja apresentada no visor LCD Use apenas cart es de dados ResScan A mensagem a seguir apresentada no visor LCD depois que voc tenta copiar dados para um cart o de dados Erro de cart o Remova o cart o O cart o de dados n o foi introduzido corret
92. de electrostatica contacto madera cemento o CEI 61000 4 2 8 kV al aire 8 kV al aire baldosas de cer mica Si os suelos est n revestidos de material sint tico la humedad relativa deberia ser por lo menos del 30 o Transitorios 2 kV para l neas 2 kV La calidad de la red de 5 el ctricos de suministro de energ a el ctrica deber ser ry rapidos en rafagas energia a de un t pico entorno Lu CEI 61000 4 4 1 kV para l neas No corresponde comercial u hospitalario de entrada salida Subida r pida de 1 kV en modo 1 kV en modo La calidad de la red de tensi n diferencial diferencial energia el ctrica deber ser CEI 61000 4 5 2 kV en modo 2 kV en modo la de un t pico entorno com n com n comercial u hospitalario Ca das de voltaje lt 5 del Ut lt 12V La calidad de la red de variaciones de gt 95 de caida gt 95 de caida en energia el ctrica deber ser voltaje e con respecto al 240V la de un t pico entorno interrupciones Ut durante 0 5 ciclos comercial u hospitalario cortas en las l neas durante 0 5 ciclos Si el usuario del equipo de entrada del VPAP Auto necesita un suministro de 40 del Ut 96 V funcionamiento continuo energia 60 de ca da con 60 de ca da en durante los cortes en el CEI 61000 4 11 respecto al Ut 240V suministro de energia se durante 5 ciclos durante 5 ciclos recomienda que el equipo VPAP Auto sea alimentado 70 del Ut 168 V por una fuente de energia 30 de caida con 30 de caida en continua
93. de oxig nio mantido o g s fornecido ao tubo de ar pode se acumular no compartimento do dispositivo e gerar risco de inc ndio Isso se aplica maioria dos tipos de dispositivos PAP e O oxig nio favorece a combust o N o use oxig nio quando estiver fumando nem em presen a de chamas desguarnecidas e Certifique se sempre de que o dispositivo est gerando fluxo de ar antes de ligar o fornecimento de oxig nio Desligue sempre o fornecimento de oxig nio antes de interromper o fluxo de ar do dispositivo Nota caso seja utilizado um fluxo de oxig nio suplementar constante a concentra o do oxig nio inspirado variar segundo o local de introdu o do g s as configura es de press o o padr o respirat rio do paciente o tipo de m scara e o ndice de fuga N o utilize o VPAP Auto caso sejam observados defeitos externos bvios ou mudan as inexplic veis no desempenho N o abra o gabinete do VPAP Auto N o existem pe as dentro do aparelho que possam ser reparadas pelo usu rio Os reparos e consertos internos s devem ser realizados por t cnicos autorizados Risco de explos o n o use na proximidade de anest sicos inflam veis Avisos relacionados com o tratamento Se interromper seu tratamento de PAP ou de dois n veis a apn ia voltar imediatamente Se por alguma raz o previr que n o poder usar sua unidade VPAP Auto consulte o m dico Informa es m dicas Portugu s Se for
94. ded to provide safe and reliable operation provided that it is operated and maintained in accordance with the instructions provided by ResMed Applicable ResMed warranty details are provided with the device at the time of original supply Of course as with all electrical devices if any irregularity becomes apparent you should exercise caution and have the device inspected by an authorized ResMed service center If you feel that your flow generator is not performing properly see Troubleshooting on page 24 Cleaning and Maintenance 23 Troubleshooting If there is a problem try the following suggestions If the problem cannot be solved contact your equipment supplier or ResMed Do not attempt to open the device Problem No display Possible Cause Power not connected Solution Ensure the appropriate power cord is connected to your VPAP Auto and the power switch if available is on Insufficient air delivered from VPAP Auto Ramp or settling time is in use Air filter is dirty Air tubing is kinked or punctured Air tubing not connected properly ask and headgear not positioned correctly Cap s missing from access port s on mask Pressure required for treatment may have changed Wait for air pressure to build up or change ramp or settling time Replace air filter Straighten or replace tubing Check air tubing Adjust position of mask and headgear Replace cap s See you
95. dos referentes ao tratamento e tamb m podem fornecer ao paciente novas configura es de tratamento sem que este tenha que sair de casa Como conectar o m dulo Para conectar o m dulo de cart es de dados empurre o sobre a porta de comunica o de dados que se encontra na parte de tr s do VPAP Auto at encaix lo no lugar G 1 Como remover o m dulo Para remover o m dulo de cart es de dados puxe o da parte de tr s do VPAP Auto G 2 Nota para proteger a porta de comunica o de dados certifique se de manter sempre um m dulo conectado parte de tr s do dispositivo Como usar o cart o de dados para coletar dados Consulte as ilustra es na se o H do folheto de ilustra es Se precisar rever o tratamento seu m dico pedir que use o cart o de dados para copiar os dados do VPAP Auto e em seguida envie o cart o para ele O cart o de dados ser fornecido em um conveniente envelope de resposta postal Os dados s o copiados no cart o de dados quando este inserido no dispositivo Os dados originais permanecer o armazenados no dispositivo A c pia dos dados para o cart o pode demorar at 30 segundos 1 Introduza o cart o de dados e Ligue o VPAP Auto e aguarde at ver a tela de espera RAMPA ou ACOMODA O Segure o cart o com a seta virada para cima e introduza o na ranhura do m dulo de cart es de dados H 1 Com cuidado empurre o cart o at o final H 2 quando algumas mensagens come
96. e Liberty Full Face Mask Mirage Quattro Full Face Mask Ultra Mirage Full Face Mask Table 3 Settings for mask types English Settings Mask ACTIVA Mirage Activa Nasal Mask SWIFT Mirage Swift Nasal Pillows System Mirage Swift Il Nasal Pillows System STANDARD Mirage Vista Nasal Mask Messages on the VPAP Auto LCD Your clinician may have set your VPAP Auto to remind you about important events such as when to replace your mask when to insert your Data Card if your device is Data Card enabled and so on The reminder message is displayed on the LCD and is visible if the device is not delivering therapy The backlight on the LCD flashes when a message is displayed Your clinician can set any of the following reminders on your LCD Message Description Action INSERT CARD May appear if your Insert your Data Card see Section H of the device is Data Card illustrations sheet and follow any instructions enabled that your clinician has given you When you have done this the message will disappear from the LCD Pressing the Left Ok key will also remove the message REPLACE ay appear when Press the Left Ok key to remove the MASK your mask is due message from your LCD and replace your for replacement mask with a new one CALL ay appear as a Press the Left Ok key to remove the PROVIDER reminder to message from your LCD and contact your contact your clinician clinician for example to discuss how your the
97. e de rampe maximale fix e par votre clinicien l aide de la touche de d placement vers le haut ou de d placement vers le bas Ecran Attente Mode VAuto Si votre clinicien a r gl un temps d attente maximal l cran Attente s affiche apr s l cran Bienvenue Dans l cran Attente vous pouvez r gler un temps d attente imm diatement Pendant le temps d attente l appareil reste la pression EPAP Min la pression inspiratoire correspondant l EPAP Min plus l aide inspiratoire Voir Temps d attente page 18 Le temps d attente peut tre modifi par incr ments de cinq minutes de OFF au temps d attente maximal fix par votre clinicien l aide de la touche de d placement vers le haut ou de d placement vers le bas Menus Le menu vous permet d afficher le nombre d heures d utilisation et la version du logiciel de votre VPAP Auto Le nombre total d heures pendant lesquelles vous avez utilis l appareil depuis sa derni re r initialisation par le clinicien est affich sur l cran Util dur e Cet cran comprend galement le nombre de jours pendant lesquels la VPAP Auto a t utilis e par rapport au nombre total de jours disponibles L cran LOG indique la version du logiciel actuellement install sur votre VPAP Auto La Figure 2 donne un r capitulatif du menu standard de la VPAP Auto Pour acc der aux menus de la VPAP Auto Appuyez sur la touche de gauche menu pendant l affichage de l cran VPAP Auto o
98. e device Use on an Aircraft Please consult the medical services department of your carrier if you intend to use your VPAP Auto on an aircraft The VPAP Auto complies with US FCC Part 15 Class B requirements if no external data cables are used Note You should not use your VPAP Auto while the aircraft is taking off or landing Operating Instructions English 21 Cleaning and Maintenance You should regularly carry out the cleaning and maintenance described in this section Refer to your mask manual for detailed instructions Daily Cleaning Mask Clean the mask according to the instructions supplied with the mask Air tubing Disconnect the air tubing from the VPAP Auto and humidifier if used and hang the tubing and mask in a clean dry place until next use Humidifier If you are using a humidifier clean it according to the instructions in the humidifier user s manual Weekly Cleaning 1 Remove the air tubing from the VPAP Auto and the mask 2 Wash the air tubing in warm water using mild detergent Rinse thoroughly hang and allow to dry 3 Before next use assemble the mask and headgear according to the user instructions 4 Reconnect the air tubing to the air outlet and mask Periodic Cleaning 1 Clean the exterior of the VPAP Auto with a damp cloth and mild liquid soap 2 Check the air filter for blockage or holes see Replacing the Air Filter on page 23 WARNING J Beware of electric shock
99. e s affiche nouveau consultez votre clinicien Affichage du message d erreur Exxxx O XXXX correspond un num ro d erreur Composant d fectueux Retournez votre VPAP Auto pour r paration Strat gie de d pannage 29 30 Probleme Le message suivant s affiche sur l cran LCD apr s que vous avez essay de mettre les r glages jour l aide de la carte de donn es ERREUR CARTE Retirez carte Cause possible La carte de donn es n est pas correctement ins r e La carte de donn es est ins r e partiellement seulement Vous avez peut tre retir la carte de donn es avant que les r glages n aient t copi s sur la VPAP Auto La carte ins r e n est pas une carte de donn es ResScan Solution V rifiez que la carte de donn es est ins r e avec la fl che dirig e vers le haut et pointant vers l appareil V rifiez que l appareil est sous tension et en mode d attente avant d ins rer la carte de donn es V rifiez que la carte de donn es est ins r e dans le module de carte de donn es jusqu la but e Ins rez la carte de donn es nouveau et attendez que le message CHARG REUSSI Retirez carte s affiche sur l cran LCD Utilisez uniquement une carte de donn es ResScan Le message suivant s affiche sur l cran LCD apr s que vous avez essay de copier les donn es sur une carte de donn es ERREUR CARTE Retirez carte La carte de donn
100. e slot in the Data Card module H 1 e Push the card in smoothly until it stops moving H 2 and messages start appearing on the LCD 2 Copy data onto the Data Card Data copying starts automatically when the Data Card is inserted into the Data Card module The Card Inserted Please Wait message is displayed on the VPAP Auto LCD while data is being copied Copying takes up to 30 seconds The Copy Complete Remove Card message is displayed on the LCD when copying has finished Remove the Data Card from the Data Card module No additional data is copied onto the card once the Copy Complete Remove Card message is displayed even if the card is left in the device To add additional data to the Data Card reinsert the card and repeat these steps 3 Remove the Data Card Grip the end of the Data Card and pull it out of the Data Card module H 3 4 Store the Data Card Your Data Card should be stored in its mailback envelope when not in use English 5 Mail the Data Card to your clinician When mailing the Data Card to your clinician 1 Insert the Data Card into the pocket provided on the mailback envelope Fold up the mailback envelope 2 Place the mailback envelope containing the Data Card in a postal envelope and seal it 3 Make sure that your clinician s name and address details are on the postal envelope and mail it back immediately Operating Instructions 19 Using the Data Card to Update Settings If your
101. e sont pas disponibles dans tous les pays e Les appareils ResMed ont t con us et fabriqu s pour procurer une performance optimale avec les masques avec fuite intentionnelle ResMed D autres masques peuvent tre utilis s mais ils peuvent affecter la performance et les donn es obtenues En mode VAuto seuls les masques ResMed sont compatibles avec la VPAP Auto Votre clinicien devra configurer votre VPAP Auto pour utilisation avec votre type de masque Le syst me VPAP Auto Fran ais Humidificateur Veuillez vous r f rer la figure de la section B de la fiche d illustrations Il est possible que vous ayez besoin d un humidificateur pour pallier les probl mes de s cheresse nasale buccale ou de la gorge auxquels vous tes confront La VPAP Auto est compatible avec l humidificateur chauffant int gr HumidAire 3i B AVERTISSEMENT Seul l HumidAire 3i est compatible avec la VPAP Auto Veuillez vous r f rer aux avertissements page 2 Accessoires Veuillez vous r f rer aux figures de la section C de la fiche dillustrations Les accessoires suivants peuvent tre utilis s avec la VPAP Auto Carte de donn es ResScan C 1 Module de carte de donn es ResScan C 2 e Module vierge C 3 e Convertisseur DC 12 C 4 e Circuit respiratoire 9 10 3 m C 5 Remarque ResMed recommande d utiliser les circuits respiratoires suivants avec la VPAP Auto circuit respiratoire 9 10 3 m gris code
102. ecla Derecha Tecla Avance START STOP Dus ft A Tecla Inicio Detenci n K Figura 1 Teclado y visor del VPAP Auto El visor se usa para mostrar los men s y otros datos Las flechas y el texto en min scula en la l nea inferior del visor brindan informaci n acerca del uso de las teclas dentro de los men s El teclado se utiliza para navegar por los men s para acceder a la funci n Ajuste de mascarilla y para iniciar detener el tratamiento Las funciones de las teclas y de las combinaciones r pidas de teclas se detallan en la Tabla 1 La luz de fondo del visor se apaga despu s de dos minutos de inactividad Se enciende nuevamente al presionar una tecla Tabla 1 Las teclas del panel frontal y sus funciones Tecla Funci n Visor e Muestra informaci n acerca del VPAP Auto incluidos los DY men s y las pantallas de tratamiento Inicio Detenci n e Inicia o detiene el tratamiento Corro Js e El mantenerla presionada durante por lo menos tres segundos inicia la funci n Ajuste de mascarilla Retroceso e Le permite desplazarse por los men s y submenus del VPAP Auto e incrementar las opciones de configuraciones Avance e Le permite desplazarse por los men s y submenus del VPAP Auto e incrementar las opciones de configuraciones Preparaci n para el uso Espa ol 9 10 Tecla Funcion Izquierda e Realiza la funci n indicada por el texto guia que aparece justo encima de ella en el visor El
103. eda em 240V por 5 segundos ambiente comercial ou hospitalar tipico Se o usuario do VPAP Auto precisar que o dispositivo continue em opera o durante cortes no fornecimento de energia recomenda se uma alimenta o por fonte n o interromp vel Campo magn tico da frequ ncia da corrente el trica 50 60Hz IEC 61000 4 8 3 A m 3 A m Os campos magn ticos da frequ ncia da corrente devem se situar a n veis pr prios de uma localiza o t pica em um ambiente comercial ou hospitalar t pico NOTA Ut a tens o da rede el trica CA antes da aplica o do n vel de teste continua na p gina seguinte Especifica es t cnicas Portugu s 35 36 Guia e declara o do fabricante Imunidade eletromagn tica O VPAP Auto deve ser utilizado no ambiente eletromagn tico especificado abaixo O cliente ou o usu rio do VPAP Auto deve se certificar de que o sistema ser utilizado somente neste ambiente N vel de teste N vel de 7 a Teste d A Ambiente eletromagn tico ne IEC 60601 1 2 conformi E imunidade orientac o dade Equipamentos de comunicac o de RF port teis e m veis n o devem ser utilizados a uma dist ncia do dispositivo VPAP Auto incluindo cabos menor que o afastamento recomendado calculado a partir da equa o aplic vel a frequ ncia do transmissor Afastamento recomendado RF conduzida 3 Vrms 3 Vrms d 1 17 VT IEC 61000 4 6 150 kHz a
104. el VPAP Auto en el suelo al lado o debajo de la cama Aseg rese de que no haya polvo en el rea y que no haya ropa ropa de cama ni ning n otro objeto que pudiera bloquear la entrada de aire Conecte el cable de alimentaci n en el enchufe de la parte trasera del generador de aire D 1 Conecte el otro extremo del cable de corriente a una toma de corriente ADVERTENCIA Aseg rese de que el cable de alimentaci n y el enchufe est n en buenas condiciones y que el equipo no est da ado Conecte firmemente uno de los extremos del tubo de aire en la salida de aire D 2 ADVERTENCIA Solamente deber utilizar tubos de aire ResMed con este generador de aire Un tubo de aire diferente podr a modificar la presi n que efectivamente recibe lo cual reducir a la eficacia del tratamiento La obstrucci n de la entrada de aire o del tubo podr a provocar un sobrecalentamiento del equipo Enel entorno cl nico toda computadora personal que se utilice con el sistema CPAP deber estar al menos a 1 5 m 5 pies del paciente o al menos 2 5 m 8 pies por encima de l Tambi n deber cumplir con la norma de prueba correspondiente Para las computadoras personales la norma internacional es la CEl 60950 o su equivalente Montaje de la mascarilla 1 2 Monte el sistema de mascarilla siguiendo las instrucciones para el usuario de la mascarilla Conecte su sistema de mascarilla al extremo libre del tubo de aire D 3 Verifique
105. ents suivants quitter et annuler Droite WY Pour vous aider r gler la VPAP Auto le clavier et l cran LCD sont quip s d un r tro clairage Le r tro clairage de l cran LCD s allume lorsque l appareil est mis sous tension ou lorsque vous appuyez sur une touche Il s teint au bout de deux minutes Le r tro clairage du clavier est allum en permanence lorsque la VPAP Auto est sous tension Utilisation des menus La VPAP Auto offre un ensemble de fonctions organis es en menus et sous menus Les menus et sous menus accessibles via l cran LCD vous permettent de visualiser et de modifier les param tres d une fonction particuli re Vous pouvez acc der aux menus que la VPAP Auto soit en mode d attente ou qu elle d livre un traitement Apr s l affichage de l cran Bienvenue et une fois que les tests automatiques de l appareil sont termin s l cran Rampe mode S et mode CPAP ou Attente mode VAuto s affiche cran Rampe Mode S et mode CPAP Si votre clinicien a r gl une dur e de rampe maximale l cran Rampe s affiche apr s l cran Bienvenue Dans l cran Rampe vous pouvez r gler une dur e de rampe imm diatement La dur e de rampe est la p riode pendant laquelle la pression augmente d une pression basse confortable la pression prescrite pour le traitement Voir Dur e de rampe page 18 La dur e de rampe peut tre modifi e par incr ments de cing minutes de OFF la dur
106. equipos ResMed determinados nicamente utilice el m dulo Tarjeta de datos ResSan si se suministra tal como se especifica en este manual Nota lo que se ha expuesto son advertencias y precauciones generales Las advertencias precauciones y notas espec ficas aparecen en el manual junto a las instrucciones pertinentes Efectos secundarios Los pacientes deben informar a su m dico acerca de todo dolor tor cico inusual un dolor de cabeza severo o un aumento en su dificultad respiratoria Una infecci n aguda de las v as respiratorias superiores puede requerir la suspensi n temporal del tratamiento Los siguientes efectos secundarios pueden surgir durante el curso del tratamiento con el dispositivo sequedad de la nariz boca o garganta epistaxis hinchaz n por tragar aire molestias sinusales o del o do irritaci n ocular erupciones cut neas molestias tor cicas Sistema VPAP Auto Consulte las figuras en la secci n A de la hoja de figuras Vista frontal A 1 Muestra el teclado el visor y la salida de aire Vista posterior A 2 Muestra d nde se acopla el m dulo y la ubicaci n del filtro de aire y de los enchufes de alimentaci n Cable de alimentaci n A 3 Cable de alimentaci n para conectar el VPAP Auto a la fuente de energ a de CA rea Bolsa para viaje A 4 Tubo de aire A 5 El tubo de aire de 2 m 6 pies 6 pulgadas conecta el VPAP Auto con su mascarilla Mascarilla Tambi n necesitar
107. ertar tarjeta 18 llamar proveedor 19 mensajes personalizados 19 ndice alfab tico Espa ol 39 realizar servicio 19 Responsabilidad del usuario propietario 1 Responsabilidad usuario propietario 1 S Sequedad 22 Soluci n de problemas 26 T Tarjeta de datos 29 ecla Avance 9 ecla Derecha 10 ecla Inicio Detenci n 9 ecla Izquierda 10 ecla Retroceso 9 eclado 5 Tiempo de adaptaci n 10 17 26 Tiempo de rampa 10 17 26 ipos de mascarilla 17 ransformador DC 12 23 ubo de aire 5 conexi n a la salida de aire 7 limpieza 24 torcido 26 U Uso 8 Uso de los men s 10 Uso del humidificador 8 uso en avi n 23 Uso internacional 23 V Viajes 23 visor LCD 5 mensajes 18 mensajes de error 29 VPAP Auto dimensiones 32 servicio de mantenimiento 25 RESMED VPAP Auto DISPOSITIVO DE PRESSAO POSITIVA DAS VIAS RESPIRAT RIAS Manual do Usu rio Portugu s Portugu s Indice Introdu o ro nbs Biter SR Bota Ge read Defini es Responsabilidade do usu rio propriet rio Informa es m dicas Para que serve o dispositivo VPAP Auto Contra indica es Avisos Precau es O Sistema VPAP Auto Mascara Oxig nio suplementar Prepara o para USO Montagem do sistema VPAP Auto Monte a m scara Instru es operacionais In cio do tratamento SmartStart M Inte
108. es de la VPAP Auto 9 caract ristiques de pression dynamique 32 carte de donn es 30 circuit respiratoire 5 nettoyage 25 raccordement la sortie d air 7 clavier 5 compatibilit lectromagn tique 33 composants 5 convertisseur DC 12 23 D d but du traitement 17 d finitions 1 dur e de rampe 11 18 27 E cran Attente 11 cran Hrs Util dur e 11 cran LCD 5 messages 19 messages d erreur 30 cran Masque 15 cran Rampe 10 F filtre a air 5 27 remplacement 26 fuites buccales 23 G garantie 39 garantie limit e 39 H HumidAire 3i 8 humidificateur 6 nettoyage 25 informations m dicales 2 installation 7 instructions d utilisation 14 irritation nasale 23 Fran ais M masque 5 ajustement du masque 15 fixation 7 position 27 type de masque 18 menu 13 menus 11 avec un humidificateur 13 utilisation 10 messages d erreur 29 modules fixation 5 N nettoyage hebdomadaire 25 p riodique 25 quotidien 25 nettoyage du masque 25 niveau de bruit 33 O oxyg ne additionnel 6 P port du masque 27 position du harnais 27 pr paration avant l utilisation 7 pression d air 27 pression ajustement du masque 15 prises d alimentation 5 R rappels 19 Index 41 appel clinicien 20 entretien chu 20 ins rer carte 19 messages personnalis s 20 remplacer filtre 20 remplacer masque 19 responsabilit de I utilisateur du propri taire 1 responsabilit utilisateur propri taire 1
109. esliga automaticamente ap s 2 minutos A luz de fundo do teclado permanece ligada quando o VPAP Auto est ligado Utiliza o dos menus A unidade VPAP Auto disp e de um conjunto de fun es dispostas em menus e submenus Na tela do visor LCD os menus e submenus permitem ver e modificar as configura es de determinada fun o Voc pode acessar os menus independentemente de o VPAP Auto estar no modo de espera ou administrando a terapia Ap s a tela de boas vindas e auto verifica o do dispositivo voc v a tela Rampa modo S e modo CPAP ou a tela Acomoda o modo VAuto Tela Rampa Modo S modo CPAP Se seu m dico tiver definido um tempo de rampa m ximo a tela Rampa ser apresentada ap s a de boas vindas Na tela Rampa voc pode definir imediatamente um tempo de rampa O tempo de rampa o per odo no qual a press o administrada aumentada de um n vel baixo at press o de tratamento prescrita Consulte Tempo de rampa na p gina 17 O tempo de rampa pode ser alterado em incrementos de cinco minutos de DESL a um tempo de rampa m ximo definido pelo m dico atrav s da tecla Para cima Para baixo Tela Acomoda o Modo VAuto Se seu m dico tiver definido um tempo de acomoda o m ximo a tela Acomoda o ser apresentada ap s a de boas vindas Na tela Acomoda o voc pode definir imediatamente um tempo de acomoda o Tempo de acomoda o o per odo durante o qual o dispositi
110. eypad and LCD The LCD is used to display the menus and other data The arrows and lowercase text on the bottom line of the LCD prompt the use of the keys within the menus The keypad is used to navigate through the menus access the mask fit feature and start stop treatment The functions of the keys and quick key combinations are listed in Table 1 The LCD backlight turns off after two minutes of inactivity It turns back on when you press a key Table 1 Keys on the front panel and their functions Key Function LCD screen e Displays VPAP Auto information including the menus and gt treatment screens Start Stop e Starts or stops treatment C e Extended hold for at least three seconds starts the mask fit feature Up e Allows you to scroll through the VPAP Auto menus and submenus and increase the settings options Down e Allows you to scroll through the VPAP Auto menus and submenus and increase the settings options Preparing for Use English 9 10 Key Function Left e Performs the function indicated by the guiding text displayed above it on the LCD screen Guiding text includes menu change and apply Right e Performs the function indicated by the guiding text displayed above it on the LCD screen Guiding text includes exit and cancel To assist you in adjusting the VPAP Auto the keypad and LCD are equipped with a backlight The LCD backlight comes on when the unit is turned on or when
111. fica o por estrelas 15 Avisos relacionados ao tratamento 3 C cabo de energia 5 26 conex o 7 Caracteristicas de press o din mica 31 Caracteristicas do VPAP Auto 9 cart o de dados 28 Compatibilidade eletromagn tica 32 Componentes 5 Configura o 7 configura es da m scara 17 conversor DC 12 23 Corrimento ou obstrucao nasal 22 D Defini es 1 Dicas teis 22 E Especifica es t cnicas 31 32 F filtro de ar 5 26 substitui o 25 fontes de energia 23 Fugas de ar pela boca 22 G Garantia 38 Garantia limitada 38 H HumidAire 3i 8 Informa es m dicas 2 In cio do tratamento 16 Instru es operacionais 13 Irrita o nasal 22 L LCD 5 mensagens 18 mensagens de erro 29 lembretes 18 chamar m dico 19 inserir cart o 18 manuten o 19 mensagens personalizadas 19 substituir filtro de ar 19 substituir m scara 18 limpeza diariamente 24 periodicamente 24 semanalmente 24 limpeza da m scara 24 limpeza di ria 24 limpeza peri dica 24 limpeza semanal 24 Luz de fundo visor LCD e teclado 10 M m scara 5 ajuste da m scara 14 conex o 7 porta 26 posi o 26 tipo de m scara 17 mensagens de erro 28 Menus 11 12 com umidificador 12 utiliza o 10 m dulos conex o 5 N N vel de ru do 32 O Oxig nio suplementar 6 P posi o do arn s 26 Prepara o para uso 7 press o do ar 26 press o ajuste da m scara 14 Indice remissivo Portugu s 39 R Re
112. ge to the VPAP Auto device The VPAP Auto should only be used with masks and connectors recommended by ResMed or by a physician or respiratory therapist A mask should not be used unless the VPAP Auto device is turned on and operating properly The vent hole or holes associated with the mask should never be blocked Explanation The VPAP Auto is intended to be used with special masks or connectors which have vent holes to allow continuous flow of air out of the mask Ports may be incorporated into the mask or in connectors that are near the mask When the device is turned on and functioning properly new air from the device flushes the exhaled air out through the mask vent holes However when the device is not operating insufficient fresh air will be provided through the mask and the exhaled air may be rebreathed Rebreathing of exhaled air for longer than several minutes can in some circumstances lead to suffocation This applies to most models of PAP devices In the event of power failure or machine malfunction remove the mask The VPAP Auto can be set to deliver pressures up to 20 cm H320 In the unlikely event of certain fault conditions pressures up to 30 cm H50 are possible If oxygen is used with this device the oxygen flow must be turned off when the device is not operating If oxygen has been left on while the device is not operating disconnect the oxygen and wait 60 minutes before turning on the device again
113. go aparece la pantalla de Rampa o Adaptaci n Nota si tiene el HumidAire 3i conectado consulte en el manual del usuario correspondiente las instrucciones de funcionamiento 2 Col quese la mascarilla siguiendo las instrucciones para el usuario de dicha mascarilla 3 Acu stese y acomode el tubo de aire de forma que pueda moverse libremente si se da la vuelta mientras duerme 4 Para comenzar el tratamiento simplemente respire por la mascarilla consulte SmartStartIM en la p gina 13 El aire comenzar a fluir lentamente y aumentar hasta llegar a la presi n total de funcionamiento en unos 10 a 15 segundos aproximadamente Nota si el VPAP Auto no comienza a funcionar autom ticamente puede presionar la tecla Inicio Detenci n SmartStart El VPAP Auto tiene una funci n denominada SmartStart SmartStart permite a su equipo encenderse autom ticamente cuando comienza a respirar con la mascarilla colocada Si el m dico ha activado SmartStop el equipo se detendr autom ticamente cuando se quite la mascarilla Parada del tratamiento Para detener el tratamiento en cualquier momento qu tese la mascarilla y pulse el bot n Inicio Detenci n o bien si su m dico ha activado la funci n SmartStop simplemente quitese la mascarilla y el tratamiento se detendr Nota SmartStop no funcionar si e Usted ha seleccionado MIR FACIAL como tipo de mascarilla Su m dico ha activado la Alerta de fuga Modo de uso Es
114. igh resulting in accumulation of water in the air tubing Avoid talking with a nasal mask on and breathe as normally as possible Adjust the headgear Adjust headgear or re fit cushion Straighten or replace air tubing Turn humidifier control dial down and empty the water from the air tubing Troubleshooting 25 Problem Display error message Check tube Key if done Possible Cause The air tubing is loose or blocked Solution Check that the air tubing is connected securely to your mask and the air outlet on the front of the VPAP Auto When you have checked the air tubing press the Start Stop key to restart the device If this does not clear the message disconnect the power cord and then reconnect it to restart the device Display error message SYSTEM ERRnnnn Call Service Component failure Record error number and contact your ResMed service center Display error message HIGH LEAK Adjust Mask You have experienced excessively high leak levels for more than 20 seconds Check that your air tubing is connected properly and that your mask does not leak excessively Use the mask fitting feature to help you to fit your mask properly If this message appears again contact your clinician Display error message Exxxx where xxxx defines an error Component failure Return your VPAP Auto for servicing The following message is displayed on the LCD
115. ils ont t achet s l origine Les r clamations au titre de la garantie pour les produits d fectueux doivent tre pr sent es au lieu d achat par le client initial Cette garantie remplace toute autre garantie expresse ou implicite y compris toute garantie implicite de qualit marchande ou d ad quation un usage particulier Certains pays ou tats n autorisent pas les limitations de dur e pour les garanties implicites il est donc possible que la limitation susmentionn e ne s applique pas votre cas ResMed ne peut tre tenue pour responsable de tout dommage accessoire ou indirect r sultant de la vente de l installation ou de l utilisation de tout produit ResMed Certains pays ou tats n autorisent ni l exclusion ni la limitation des dommages accessoires ou indirects il est donc possible que la limitation susmentionn e ne s applique pas votre cas Cette garantie vous octroie des droits reconnus par la loi et vous pouvez galement avoir d autres droits qui varient en fonction du pays o vous habitez Pour de plus amples informations sur vos droits de garantie veuillez contacter votre prestataire de sant ou ResMed Garantie limit e Fran ais R001 307 2 05 06 40 Index A accessoires 6 ajustement du masque 15 23 note en toiles 16 alimentations 23 astuces 23 avertissements a propos du traitement 3 avion 24 C c ble d alimentation 5 27 branchement 7 caract ristiques 32 33 caract ristiqu
116. imited Warranty 35 M Mask 5 attaching 7 mask fit 14 mask type 16 port 24 position 24 Mask fit 13 star rating 14 ask fitting 20 ask screen 14 ask settings 16 ask types 16 edical information 2 enus 11 12 using 10 with humidifier 12 Modules attaching 5 Mouth leaks 20 M M M M M M N Nasal irritation 20 Noise level 29 O Operating instructions 13 Oxygen supplemental 6 P Periodic cleaning 22 Power cord 5 24 connecting 7 Index 37 38 Power sockets 5 Power sources 21 Preparing for use 7 Pressure mask fit 14 R Ramp screen 10 Ramp time 10 16 24 Reminders 17 call provider 17 customized messages 18 insert card 17 replace air filter 17 replace mask 17 service due 18 Responsibility user owner 1 Right key 10 Runny or blocked nose 21 S Setting up 7 Settling screen 10 Settling time 10 16 24 Start stop key 9 Starting treatment 15 Supplemental oxygen 6 T Technical specifications 28 29 Traveling 21 Troubleshooting 24 U Up key 9 Use on aircraft 21 Used time screen 11 User owner responsibility 1 Using the menus 10 V VPAP Auto dimensions 29 servicing 23 W Warnings related to treatment 3 Warranty 35 Weekly cleaning 22 RESMED VPAP Auto APPAREIL DE PRESSION POSITIVE Guide utilisateur Fran ais Fran ais Sommaire Introduction D finitions Responsabilit de l utilisateur du propri taire Informati
117. ionando si se deja abierto el flujo de oxigeno el oxigeno suministrado al tubo de ventilaci n podra acumularse dentro del equipo PAP lo que provocar un riesgo de incendio Esto se aplica a la mayoria de los tipos de equipos PAP El ox geno favorece la combusti n Por lo tanto no debe utilizarse en presencia de una llama expuesta o mientras se fuma Siempre aseg rese de que se genere flujo de aire por parte del equipo antes de encender el suministro de ox geno Siempre apague el suministro de ox geno antes de detener el flujo de aire desde el equipo Nota A un caudal fijo de oxigeno suplementario la concentraci n de oxigeno inhalado variar dependiendo del punto en que ste se introduce las configuraciones de presi n programadas el ritmo respiratorio del paciente la mascarilla elegida y el caudal de fuga No utilice el VPAP Auto si presenta defectos externos obvios u ocurren cambios inexplicados en su funcionamiento No abra la carcasa del VPAP Auto No hay piezas dentro que el usuario pueda reparar Las reparaciones y el mantenimiento interno deber n ser efectuados Unicamente por un agente de servicio autorizado Peligro de explosi n no utilizar cerca de anest sicos inflamables Advertencias relativas al tratamiento Si abandona el tratamiento con PAP o binivel su apnea del sueno volver inmediatamente Consulte siempre a su m dico si espera encontrarse en una situaci n en la que no podr utilizar
118. ions in section G of the illustration sheet The ResScan Data Card module is an accessory to the VPAP Auto Use a ResScan Data Card with the Data Card module to collect data and update settings in the VPAP Auto The module and card give your clinician convenient access to data about your treatment and can provide you with new device settings from your clinician without your having to leave home Attaching the Module To attach the Data Card module push it onto the data communications port at the back of your VPAP Auto until it clicks into place G 1 Removing the Module To remove the Data Card module pull it off the back of the VPAP Auto G 2 Note To protect the data communications port always ensure there is a module attached to the back of the device Using the Data Card to Collect Data Please refer to the illustrations in section H of the illustration sheet If your clinician needs to review your treatment they will ask you to use the Data Card to copy data from your VPAP Auto and to return the card to them The Data Card will be provided in a convenient mailback envelope Data is copied onto the Data Card when it is inserted into the device The original data will remain stored on the device It takes up to 30 seconds to copy data onto the Data Card 1 Insert the Data Card e Switch on the VPAP Auto and wait until you see the standby RAMP or SETTLING screen e Hold the Data Card with the arrow facing up and insert it into th
119. itros por minuto Volume corrente volume de ar inalado em cada respira o mililitros por respira o Respira o fase expira o este item de tela apresentado no formato tipo de respira o apresenta o de fase tipo de expira o como mostra o texto a seguir por exemplo S TiMn Tipo de respira o S espont nea Apresenta o de fase inspira o em branco expira o Tipo de expira o TiMn expira o acionada na conclus o do tempo m ximo de reten o de inspira o TiMx expira o acionada na conclus o do tempo m ximo de reten o de inspira o C expira o acionada espontaneamente dentro dos valores de TiMin e TiMax Tempo de rampa Modo S modo CPAP O tempo de rampa um recurso que pode ser ativado pelo m dico Se tiver dificuldades em adormecer com a press o total selecione um tempo de rampa O fluxo de ar come ar a circular lentamente enquanto voc adormece A press o ser aumentada lentamente at alcan ar a press o total de funcionamento no decorrer do tempo de rampa O m dico definiu um tempo de rampa m ximo Voc poder selecionar um valor qualquer at esse m ximo Tempo de acomoda o Modo VAuto O tempo de acomoda o um recurso que pode ser ativado pelo seu m dico Caso tenha dificuldades para dormir com o funcionamento do VPAP Auto selecione um tempo de acomoda o O fluxo de ar permanecer na Press o M nima pelo per odo definido de forma que vo
120. iza o com o VPAP Auto Cart o de dados ResScan C 1 M dulo de cart es de dados ResScan C 2 e M dulo de prote o C 3 Conversor DC 12 C 4 Tubo de ar de 3 m 118 pol C 5 Nota a ResMed recomenda os seguintes tubos para utilizac o com o VPAP Auto tubo de ar de 3 m 118 pol cinza NP 14980 tubo de ar de 2 m 78 pol cinza NP 14948 tubo de ar descart vel transparente NP 14912 Oxig nio suplementar O VPAP Auto foi projetado para ser compat vel com o uso de terapia de baixo fluxo de oxig nio administrada de uma fonte externa Caso seja utilizado um fluxo de oxig nio suplementar constante a concentrac o de oxig nio inspirado variar de acordo com as configura es de press o o padr o respirat rio do paciente a op o de m scara e o indice de fuga Isso se aplica maioria dos tipos de dispositivos PAP Preparacao para uso Montagem do sistema VPAP Auto 1 Coloque o VPAP Auto sobre uma mesa pr ximo cabeceira da cama PRECAU O Coloque o dispositivo em local seguro onde n o seja poss vel derrub lo acidentalmente nem trope ar no cabo de energia Nota o VPAP Auto tamb m pode ser colocado no ch o ao lado da cama ou debaixo dela Certifique se de que o local n o est empoeirado nem cont m roupa de cama pe as de vestu rio ou outros itens que possam obstruir a entrada de ar Conecte o cabo de energia tomada que se encontra na parte de tr s do gerador de fl
121. la Para cima Para baixo para percorrer os itens dentro do mesmo n vel a tecla Esquerda para entrar num submenu e aplicar uma op o e a tecla Direita para sair de um menu ou submenu e para sair sem alterar as op es Satura o de oxig nio SpO2 a satura o da hemoglobina no sangue Frequ ncia card aca FC o n mero de batimentos card acos em um per odo de 60 segundos batimentos por minuto Instru es operacionais In cio do tratamento A unidade VPAP Auto deve ser montada junto cama com o tubo dear e o sistema de m scara conectados Consulte Montagem do sistema VPAP Auto na p gina 7 1 Conecte o cabo de energia fonte de alimenta o Uma mensagem de boas vindas exibida no visor LCD A tela Rampa ou Acomoda o apresentada Nota se o HumidAire 3i se encontrar conectado consulte o manual de usu rio relevante para obter instru es operacionais 2 Coloque a m scara da forma descrita nas instru es do usu rio da m scara 3 Deite se e posicione o tubo de ar de forma que possa se movimentar livremente para o caso de se virar durante o sono 4 Para iniciar o tratamento basta respirar na m scara consulte SmartStart na p gina 13 O ar come ar a circular lentamente at atingir a press o total de funcionamento em cerca de 10 a 15 segundos Nota seo VPAP Auto n o iniciar automaticamente pressione a tecla Iniciar Parar SmartStart O VPAP Auto tem um recu
122. la serie del men est ndar del VPAP Auto e Para acceder a los men s del VPAP Auto Oprima la tecla Izquierda men mientras aparece la pantalla de VPAP Auto od e Rampa o Adaptaci n Para desplazarse por los art culos del men Opr ima la tecla Retroceso Avance e Para salir del menu Opr Figura ima la tecla Derecha salir Modo VAuto Modo S y modo CPAP ADAPTC 20min men RAMPA 20min men ESPIRACI N MED cambiar salir USADO 00000hs 00000 00000dia MASC MIR FULL cambiar 1 salir VER SX3650201 t salir 2 Serie del menu del VPAP Auto Nota la pantalla de espiraci n s lo est disponible si la activa un m dico Preparaci n para el uso Espafiol Men s con un humidificador Si el HumidAire 3i esta conectado al VPAP Auto y el tratamiento no ha comenzado el VPAP Auto mostrara una de las siguientes pantallas RAMPA 20min menu t calen ADAPTC 20min menu a calen Modos CPAP y S Modo VAuto muestra la configuraci n de RAMPA muestra la configuraci n de ADAPTACION Figura 3 Pantalla del men del paciente con humidificador antes de comenzar el tratamiento Luego de haber comenzado el tratamiento la pantalla de tratamiento muestra consulte Figura 5 Pantallas de tratamiento todos los modos en la p gina 16 Men s con una ResLink y un ox metro Si el m dico ha recomendado que use un m du
123. le module de carte de donn es poussez le sur le port de communication de donn es l arri re de votre VPAP Auto jusqu ce qu il se verrouille en position G 1 Retrait du module Pour retirer le module de carte de donn es tirez dessus pour le d tacher de la VPAP Auto G 2 Remarque pour prot ger le port de communication de donn es veillez ce qu un module soit fix l arri re de l appareil en permanence Utilisation de la carte de donn es pour collecter des donn es Veuillez vous r f rer aux figures de la section H de la fiche d illustrations Lorsque votre clinicien veut consulter les donn es de votre traitement il vous demande d utiliser la carte de donn es pour copier les donn es de votre VPAP Auto et de lui envoyer la carte La carte de donn es est fournie dans une enveloppe de retour Les donn es sont copi es sur la carte de donn es lorsque celle ci est ins r e dans l appareil Les donn es ainsi copi es sont conserv es dans la m moire de l appareil La copie des donn es sur la carte de donn es peut prendre jusqu 30 secondes 1 Insertion de la carte de donn es Mettez la VPAP Auto sous tension et attendez que l cran d attente RAMPE ou ATTENTE s affiche e Prenez la carte de donn es avec la fl che dirig e vers le haut et ins rez la dans la fente du module de carte de donn es H 1 Poussez la carte sans forcer jusqu la but e H 2 et jusqu ce que des messages commencent
124. lit de I utilisateur du propri taire L utilisateur ou le propri taire de cet appareil sera tenu pour seul responsable de toute blessure ou de tout dommage mat riel r sultant d une utilisation non conforme aux instructions fournies d un entretien ou de modifications r alis s non conform ment aux instructions et ou par des personnes non autoris es Veuillez lire ce guide attentivement avant d utiliser l appareil Introduction 1 Informations m dicales Usage pr vu pour la VPAP Auto La VPAP Auto est pr vue pour le traitement du syndrome d apn e obstructive du sommeil SAOS chez les patients de plus de 66 Ib 30 kg Elle est pr vue pour une utilisation en milieu hospitalier ou a domicile ATTENTION USA UNIQUEMENT Selon la loi f d rale am ricaine ce dispositif ne peut tre vendu aux U S A que par un m decin ou sur prescription m dicale Contre indications Le traitement par pression positive est contre indiqu chez certains patients pr sentant l une des pathologies pr existantes suivantes affection pulmonaire bulleuse grave pneumothorax hypotension d shydratation fuite de liquide c phalo rachidien r cent traumatisme cr nien ou intervention chirurgicale cr nienne Avertissements Lire le manuel enti rement avant d utiliser la VPAP Auto Les conseils donn s dans ce manuel ne remplacent pas les instructions du m decin traitant Un patient ne doit connecter aucun appareil au
125. lo ResLink y la ResLink y un oximetro est n conectados al VPAP Auto tiene prioridad la pantalla de SpO saturaci n de ox geno y FC frecuencia card aca Si el tratamiento no ha comenzado el VPAP Auto mostrar una de las siguientes pantallas haya o no conectado un humidificador Antes de comenzar el tratamiento SpO2 98 RAMPA 20min 98 ADAPTC 20min 98 men FC 60 men 1 Fc 60 men FC 60 Rampa M x apagada Rampa M x configurada Adaptaci n M x configurada o bien a un valor diferente de cero a un valor diferente de cero Adaptaci n M x apagada Figura 4 Pantalla de men con ResLink y ox metro Acceso a los men s Para navegar y realizar selecciones en el men del Paciente utilice la tecla Retroceso Avance para desplazarse por las opciones en un mismo nivel la tecla Izquierda para entrar en un submenu y para aplicar una opci n latecla Derecha para salir de un men o submenu sin cambiar las opciones Saturaci n de oxigeno SpO2 Saturaci n de hemoglobina en la sangre Frecuencia card aca FC El n mero de pulsaciones cardiacas durante un periodo de 60 segundos pulsaciones por minuto Modo de uso Inicio del tratamiento La unidad VPAP Auto debe instalarse junto a su cama y tener los tubos de aire y el sistema de mascarilla conectados Ver Configuraci n de VPAP Auto en la pagina 7 1 Enchufe el cable a la fuente de alimentaci n Se muestra un mensaje de bienvenida en el visor Lue
126. ls on the Data Card do not match the details on your device Contact your clinician immediately The following message is displayed on the LCD after you try to update the settings using the Data Card Settings Error Remove Card There is a data error on the Data Card Contact your clinician immediately The following message is NOT displayed on the LCD after you try to update the settings using the Data Card Settings Success Remove Card The settings were not updated Contact your clinician immediately Troubleshooting English 21 28 Technical Specifications Performance Operating pressure range 3 to 20 cm H 0 Maximum single fault pressure 30 cm H20 Pressure measurement tolerance 0 5 cm H 0 4 of the measured reading Flow measurement tolerance 0 1 or 20 of reading whichever is greater Dynamic pressure characteristics VAuto mode 4 to 20 cm H20 measured at the mask Min EPAP pressure 4 cm H20 Max IPAP pressure 20 cm H20 Pressure Support O to 10 cm H 0 S mode PAP 5 to 20 cm H20 measured at the mask EPAP 3 to 20 cm H20 measured at the mask CPAP mode 4 to 20 cm H20 measured at the mask Sound pressure level Radiated sound pressure is measured at lt 30 dBA at 10 cm H20 and 3 3 37 1 m according to 15017510 Dimensions L x W x H 4 4 x 6 5 x 5 7 112 mm x 164 mm x 145 mm Weight 2 9 b 1 3 kg Power supply Input range 100 240V 50 60Hz 40VA typical p
127. m scara a almofada da m scara e o arn s enquanto estiver deitado Tabela 2 Defini es da classifica o por estrelas do ajuste da m scara Classifica o por estrelas Defini o Et Excelente PERS uito bom om juste a m scara B A Ajuste a m scara A juste a m scara 4 Ap s tr s minutos a press o retorna press o definida e o tratamento iniciado Se n o quiser esperar tr s minutos mantenha a tecla Iniciar Parar pressionada por pelo menos tr s segundos para iniciar imediatamente o tratamento Se voc pressionar a tecla Iniciar Parar por menos de tr s segundos a unidade voltar ao modo de espera a tela RAMPA ou ACOMODACAO ser exibida Instru es operacionais Portugu s 15 16 modo CPAP modo S modo VAuto as primeiras telas ser o exibidas somente se Rampa ou Acomoda o forem selecionadas Indicador de Modo Rampa Indicador de Modo Rampa Indicador de Modo Acomoda o Press o EPAP def EPAP Press o IPAP def IPAP Press o CPAP E SUBIDA 8 0 11 0 VA ASST 8 0 11 0 gt gt gt gt 4 AP 3 0 A gt gt gt gt AP 3 0 Suporte de press o Indicador de Apn ia Fuga Ventila o por minuto l min Frequ ncia respirat ria RPM Volume corrente ml FG 24L min FR 12 VM 12 0 VC 1000 Linha superior apenas modo VAuto e S Respira o fase expira o Tempo m dio de inspira o ltimas cinco respi
128. m scara em local seco e limpo at a pr xima utiliza o Umidificador Se estiver usando um umidificador limpe o de acordo com as instru es contidas no manual do usu rio correspondente Limpeza semanal 1 Remova o tubo de ar da unidade VPAP Auto e da m scara 2 Lave o tubo de ar em gua morna e detergente suave Enx g e bem e pendure para secar 3 Antes da pr xima utiliza o monte a m scara e o arn s de acordo com as instru es para o usu rio da m scara 4 Volte a conectar o tubo de ar sa da de ar e m scara Limpeza peri dica 1 Limpe o exterior do VPAP Auto com pano mido e detergente l quido suave 2 Verifique se o filtro de ar n o est perfurado ou bloqueado consulte Substitui o do filtro de ar na p gina 25 AVISO J Cuidado com choques el tricos N o mergulhe a unidade nem o cabo de energia em gua Antes de limpar sempre remova o plugue de energia da tomada e antes de reconect lo certifique se de que est seco A m scara e o tubo de ar est o sujeitos a desgaste normal devido ao uso Verifique regularmente se est o danificados 24 Substitui o do filtro de ar Para substituir o filtro de ar 1 Remova a tampa do filtro de ar que se encontra na parte de tras do VPAP Auto Tampa do filtro de ar 2 Remova e jogue fora o filtro de ar usado 3 Introduza um filtro novo com a face azul voltada para fora 4 Volte a colocar a tampa do filtro de ar
129. ma 15017510 Dimensiones L x An x Al 112 mm x 164 mm x 145 mm 4 4 pulgadas x 6 5 pulgadas x 5 7 pulgadas Peso 1 3 kg 2 9 libras Alimentaci n Rango de entrada 100 240V 50 60Hz 40VA consumo de energ a t pico lt 100VA m ximo consumo de energ a Construcci n de la carcasa termopl stico de ingenier a ign fuga Condiciones ambientales Temperatura de funcionamiento entre 5 C y 35 C entre 41 F y 95 F umedad de funcionamiento 10 95 sin condensaci n Temperatura de almacenamiento y de transporte entre 20 C y 60 C entre 4 F y 140 F umedad de almacenamiento y de transporte 10 95 sin condensaci n Altitud para el funcionamiento desde el nivel del mar hasta 2591 m 8500 pies Compatibilidad electromagn tica El producto cumple con todos los requisitos pertinentes en cuanto a compatibilidad electromagn tica EMC por sus siglas en ingl s de acuerdo con a CEI 60601 1 2 para entornos residenciales comerciales y de industria ligera Para obtener m s detalles vea Gu a y declaraci n del fabricante Emisiones e inmunidad electromagn ticas en la p gina 34 Especificaciones t cnicas Espa ol 31 32 Nivel de ruido VPAP Auto modo CPAP presi n establecida 10 cm H 0 Total medido de ponderaci n A del nivel de presi n 24 dBA ac stica dB re 20 uPa Error de medici n dB re 20 uPa 2 dBA Los valores medidos se determinaron seg n el procedi
130. miento de prueba ac stica proporcionado en la norma ISO 17510 1 Nota La suma de un valor de emisi n sonora medido y su error de medici n asociado representa el l mite superior del rango de valores que se producen durante la medici n a Valores de n meros duales declarados de emisi n sonora seg n la norma ISO 4871 Filtro de aire dos capas de fibra de poli ster no entrelazada con uni n de polvo Tubo de aire pl stico flexible 1 x 2 m 6 pies 6 pulgadas de longitud Salida de aire la salida de aire c nica de 22 mm cumple con EN 1281 1 Clasificaci n CEI 60601 1 Clase II doble aislaci n Tipo CF Nota el fabricante se reserva el derecho de cambiar estas especificaciones sin previo aviso Accesorios Tarjeta de datos Dimensiones largo x ancho x profundidad 65 04 mm x 22 15 mm x 0 85 mm 2 56 pulgadas x 0 87 pulgadas x 0 03 pulgadas M dulo Tarjeta de datos Dimensiones altura x ancho x profundidad 49 7 mm x 42 2 mm x 12 mm 1 95 pulgadas x 1 66 pulgadas x 0 47 pulgadas Nota el fabricante se reserva el derecho de cambiar estas especificaciones sin previo aviso Simbolos que aparecen en el equipo v b IPX1 1 START STOP Mask fit Atenci n consultar la documentaci n adjunta Equipo tipo CF Equipo Clase Il A prueba de goteo Voltaje peligroso Inicio Detenci n y Ajuste de mascarilla Especificaciones t cnicas 33 Espafiol 34 Guia y
131. nform the medical staff that you are being treated with PAP or bilevel It is also important to contact the clinician who is treating you for sleep apnea If you experience an infection of the upper respiratory tract middle ear or sinuses contact your clinician before continuing your PAP or bilevel treatment You may be advised to stop treatment until the infection has cleared If you continue with treatment during an infection be sure to clean your mask and tubing after every use Cautions At low pressures the flow through the exhalation ports of your mask may not clear all exhaled gas from the tubing Some rebreathing may occur The airflow for breathing produced by this device can be as much as 11 F 6 C higher than the temperature of the room Caution should be exercised if the room temperature is warmer than 90 F 32 C When AC mains power 100 240V AC is not available always use a ResMed DC 12 converter The DC 12 converter is available as an optional accessory If supplied the ResScan Data Card module is designed for use with specific ResMed devices Only use the ResSan Data Card module if supplied as specified in this manual Note The above are general warnings and cautions Specific warnings cautions and notes appear with the relevant instructions in the manual Adverse Effects Patients should report unusual chest pain severe headache or increased breathlessness to their prescribing physician An acute uppe
132. nsi que du niveau de fuite Ne pas utiliser la VPAP Auto en cas de d fauts externes vidents ou si sa performance devient al atoire Ne pas ouvrir le bo tier de la VPAP Auto Il ne contient aucune pi ce pouvant tre entretenue par l utilisateur Les r parations et l entretien interne doivent tre effectu s par un technicien agr Danger d explosion Ne pas utiliser l appareil proximit d anesth siques inflammables Avertissements propos du traitement Votre apn e du sommeil r appara tra imm diatement si vous arr tez votre traitement par pression positive ou deux niveaux de pression Syst matiquement consulter votre m decin si vous pensez que vous allez vous trouver dans une situation o vous ne serez pas en mesure d utiliser votre VPAP Auto Informations m dicales Fran ais 3 En cas d hospitalisation ou d autres formes de traitement m dical syst matiquement informer le personnel m dical de votre traitement par pression positive ou deux niveaux de pression Il est galement important de contacter le clinicien qui vous suit pour votre syndrome d apn e du sommeil En cas d infection des voies a riennes sup rieures de l oreille moyenne ou des sinus consulter votre m decin avant de poursuivre votre traitement par pression positive ou deux niveaux de pression Il est possible qu il vous conseille d arr ter le traitement jusqu la disparition de l infection Si vous poursuivez le t
133. nt au moins trois secondes pour commencer le traitement imm diatement Si vous appuyez sur la touche Marche Arr t pendant moins de 3 secondes l appareil retourne en mode d attente l cran RAMPE ou ATTENTE s affiche Mode CPAP Mode S Mode VAuto Les premiers crans ne s affichent que si l option Rampe ou Attente est s lectionn e Indicateur de mode rampe Indicateur de mode rampe Indicateur de mode attente Pression EPAP r gl e EPAP IPAP Pression PPC Pression IPAP r gl e S RAMP gt gt 1 8 0 11 0 VA ATT 8 0 11 0 Al 3 0 A gt gt gt gt Al 3 0 Francais Al r gl e Aide inspiratoire SPONT 8 0 11 0 VAUTO 8 0 11 0 gt gt gt y Al 3 0 A gt gt gt gt Al 3 0 Graphique de pression Indicateur d apn e Fr quence respiratoire bpm Volume courant ml Fuites Ventilation minute l min FT 24L min FR 1 VM 12 0 VC 1000 Ligne du haut modes VAuto et S uniquement R glage TiMax sec Rapport E moyen 5 derni res respirations Respiration phase expiration Temps inspiratoire moyen 5 derni res respirations S TiMn Ti2 1s TiMx 4 0 t 1 16 Remarque les valeurs r gl es sont celles s lectionn es par le clinicien Figure 5 crans de traitement tous les modes Les crans de traitement contiennent les informations suivantes Mode de traitement le mode de traitement est r gl par votre clinicien Les opti
134. nt le traitement notamment pendant les mois d hiver Dans de nombreux cas l utilisation d un humidificateur permet de pallier ce probl me Contactez votre clinicien pour plus de d tails Rhinorrh e ou nez bouch Il est possible que vous ternuiez et ou que votre nez coule ou se bouche lors des premi res semaines de traitement Dans de nombreux cas ces sympt mes d irritation nasale peuvent tre limin s l aide d un humidificateur Contactez votre clinicien pour plus de d tails Utilisation avec une alimentation CC Vous devez obligatoirement utiliser un convertisseur DC 12 ResMed pour la connexion de la VPAP Auto une alimentation de 12 ou 24 V CC Contactez votre prestataire de sant ou ResMed pour de plus amples informations AVERTISSEMENT L appareil ne doit pas tre connect simultan ment une alimentation CA et une alimentation CC Instructions d utilisation Fran ais 23 24 Voyager avec la VPAP Auto Utilisation l tranger Votre VPAP Auto est quip e d une carte d alimentation qui lui permet de fonctionner dans diff rents pays Elle peut fonctionner avec des courants de 100 240 V et 50 60 Hz Aucun r glage sp cial n est requis mais vous aurez besoin d un adaptateur de prise pour le pays o vous voulez utiliser l appareil Utilisation en avion Veuillez consulter le service m dical de votre compagnie a rienne si vous souhaitez utiliser votre VPAP Auto bord d un avion La V
135. o POSITIVE AIRWAY PRESSURE DEVICE User Guide English English Contents Introduction Definitions User Owner Responsibility Medical Information What the VPAPTM Auto Device is Intended for Contraindications Warnings Cautions The VPAP Auto System Mask Supplemental Oxygen Preparing for Use Setting Up the VPAP Auto Assemble the Mask Operating Instructions Starting Treatment SmartStart Stopping Treatment Using the Mask Fitting Feature Messages on the VPAP Auto LCD Modules Helpful Hints Cleaning and Maintenance Daily Cleaning Weekly Cleaning Periodic Cleaning Replacing the Air Filter Servicing Troubleshooting Technical Specifications Accessories Symbols which Appear on the Device Limited Warranty N BNMNN Introduction Definitions This guide contains special terms and icons that appear in the margins to draw your attention to specific and important information e Warning alerts you to possible injury e Caution explains special measures for the safe and effective use of the device Note is an informative or helpful note User Owner Responsibility The user or owner of this system shall have
136. o do somente neste ambiente Teste de N vel de teste N vel de aos sti imunidade IEC 60601 1 2 conformidade S Stromagn tico orienta o Descarga 6 kV contato 6 kV contato O ch o deve ser de eletrost tica 8kVar 8kVar madeira cimento ou IEC 61000 4 2 cer mico Se o ch o se encontrar coberto por material sint tico a umidade relativa dever ser de pelo menos 30 Surto 2 kV para linhas 2 kV A qualidade da energia da transiente el trico de alimenta o de rede el trica deve ser r pido energia equipar vel de um IEC 61000 4 4 1 kV para linhas N o aplic vel ambiente comercial ou de entrada sa da hospitalar t pico Sobretens o 1 kV modo 1 kV modo A qualidade da energia da IEC 61000 4 5 diferencial diferencial rede el trica deve ser 2 kV modo 2 kV modo equiparavel de um comum comum ambiente comercial ou hospitalar t pico Quedas de tens o lt 5 Ut lt 12V A qualidade da energia da pequenas gt 95 de queda gt 95 de queda rede el trica deve ser interrup es e em Ut em 240V equipar vel de um flutua es de tens o nas linhas de alimenta o IEC 61000 4 11 por 0 5 de ciclo 40 Ut 60 de queda em Ut por 5 ciclos 70 Ut 30 de queda em Ut por 25 ciclos lt 5 Ut gt 95 de queda em Ut por 5 seg por 0 5 de ciclo 96 V 60 de queda em 240V por 5 ciclos 168 V 30 de queda em 240V por 25 ciclos lt 12V gt 95 de qu
137. o de aire Servicio de mantenimiento Soluci n de problemas Especificaciones t cnicas Accesorios S mbolos que aparecen en el equipo Garantia limitada ndice alfab tico N BNMNN Introduccion Definiciones Este manual contiene t rminos e conos especiales que aparecen en los m rgenes para dirigir su atenci n hacia informaci n espec fica e importante Una Advertencia le alerta sobre la posibilidad de lesiones Una Precauci n explica medidas especiales a tomar para el uso seguro y eficaz del dispositivo e Una Nota es una nota informativa o til Responsabilidad del usuario propietario El usuario o propietario de este sistema ser enteramente responsable de cualquier lesi n a personas o da os a bienes que resulten de una operaci n no conforme con las instrucciones de funcionamiento suministradas mantenimiento o modificaciones efectuadas a menos que sean conformes con instrucciones autorizadas y realizadas por personas autorizadas Sirvase leer este manual detenidamente antes de usar el equipo Introducci n 1 Espafiol Informacion m dica Para qu esta disenado el equipo VPAP Auto E VPAP Auto es indicado para el tratamiento de la apnea obstructiva del sue o AOS en pacientes que pesan m s de 30 kg 66 Ib Est dise ado para su uso en hospitales y en hog
138. o se entrega el equipo nuevo se acompa an los datos acerca de la garant a correspondiente de ResMed De todas formas y tal como ocurre con todos los equipos el ctricos si detecta alguna irregularidad en su funcionamiento deber tomar precauciones y hacer revisar el equipo por parte de un centro de servicio autorizado por ResMed Si considera que su generador de aire no est funcionando como debiera vea Soluci n de problemas en la p gina 26 Limpieza y mantenimiento Espa ol 25 26 Solucion de problemas Si hay un problema intente las siguientes sugerencias Si el problema no puede ser resuelto p ngase en contacto con el proveedor de su equipo o con ResMed No intente abrir el equipo Problema No se ve nada en la pantalla Causa posible La alimentaci n no esta conectada Soluci n Verifique que el cable de alimentaci n adecuado est conectado al VPAP Auto y que est encendido el interruptor de la fuente de alimentaci n en caso de haberlo El VPAP Auto proporciona insuficiente aire Se esta usando el Tiempo de rampa o el Tiempo de adaptaci n El filtro de aire est sucio El tubo de aire est torcido o roto El tubo de aire no est debidamente conectado La mascarilla y el arn s no est n correctamente colocados Falta n tap n es en el los puerto s de acceso de la mascarilla Puede ser que la presi n necesaria para el tratamiento haya cambiado Espere a
139. omagn tique La VPAP Auto est pr vue pour une utilisation dans l environnement lectromagn tique d crit ci dessous Le client ou l utilisateur de la VPAP Auto doit s assurer que celle ci est utilis e dans un environnement de ce type Fran ais Essai de Ni d E Ni d contr le de voan C ossa eeu ce Environnement lectromagn tique Guide i ae CEI60601 1 2 conformit immunit Les quipements de communication RF portables et mobiles ne doivent pas tre utilis s proximit des composants de la VPAP Auto y compris les c bles une distance inf rieure la distance de s paration recommand e calcul e sur la base de l quation applicable la fr quence de l metteur Distance de s paration recommand e RF transmises 3 Vrms 3 Vrms d 1 17 VP par conduction 150 kHz 80 MHz CEI 61000 4 6 RF transmises 10 V m 10 V m d 0 35 VP 80 MHz 800 MHz par radiation 80 MHz 2 5 GHz CEI 61000 4 3 d 0 70 VP 800 MHz 2 5 GHz o P correspond la puissance nominale de sortie maximale de l metteur en watts W indiqu e par le fabricant de l metteur et d correspond la distance de s paration recommand e en m tres m Lintensit des champs d metteurs RF fixes telle qu elle est d termin e par l tude d un site lectromagn tique doit tre inf rieure au niveau de conformit pour chaque plage de fr quences b Des interf rences peuvent se produire a proximit d quipemen
140. omagn tique d pend de l absorption et de la r flexion des structures des objets et des personnes Garantie limit e ResMed garantit votre produit ResMed contre tout d faut de mat riaux et de main d uvre pour la p riode sp cifi e ci apr s compter de la date d achat par le client d origine Cette garantie n est pas cessible Produit Dur e de la garantie Humidificateurs ResMed ResControl ResLink 1an ResTraxx Appareils de traitement ResMed 2 ans Accessoires masques y compris entourage rigide 90 jours bulle harnais et circuit respiratoire Les appareils a usage unique sont exclus Remarque certains de ces mod les ne sont pas disponibles dans tous les pays En cas de d faillance du produit dans des conditions normales d utilisation ResMed son enti re discr tion r pare ou remplace le produit d fectueux ou toute pi ce Cette garantie limit e ne couvre pas a tout dommage r sultant d une utilisation incorrecte d un usage abusif ou d une modification ou transformation op r e sur le produit b les r parations effectu es par tout service de r paration sans l autorisation expresse de ResMed c tout dommage ou contamination caus par de la fum e de cigarette de pipe de cigare ou autre d tout dommage caus par de l eau renvers e sur ou dans un appareil La garantie est annul e pour les produits vendus o revendus dans un pays autre que celui o
141. on from structures objects and people Limited Warranty ResMed warrants that your ResMed product shall be free from defects in material and workmanship for the period specified below from the date of purchase by the initial consumer This warranty is not transferable English Product Warranty Period ResMed humidifiers ResControl ResLink ResTraxx 1 Year ResMed flow generators 2 Years Accessories mask systems including mask frame cushion 90 Days headgear and tubing Excludes single use devices Note Some models are not available in all regions If the product fails under conditions of normal use ResMed will repair or replace at its option the defective product or any of its components This Limited Warranty does not cover a any damage caused as a result of improper use abuse modification or alteration of the product b repairs carried out by any service organization that has not been expressly authorized by ResMed to perform such repairs c any damage or contamination due to cigarette pipe cigar or other smoke d any damage caused by water being spilled on or into a flow generator Warranty is void on product sold or resold outside the region of original purchase Warranty claims on defective product must be made by the initial consumer at the point of purchase This warranty is in lieu of all other express or implied warranties including any implied warranty of merchantability o
142. on page 16 Settling time can be altered in five minute increments from OFF to a maximum settling time set by your clinician by the using the Up Down key Menus The menu allows you to view details about the time used and the current software version of your VPAP Auto The Used time screen displays the total number of hours for which you have used the device since it was last reset by the clinician It also displays the number of days the VPAP Auto was used out of the total number of days available for use The SW screen displays the current software version that is installed in your VPAP Auto Figure 2 summarizes the VPAP Auto standard menu series To access the VPAP Auto menus Press the Left key menu while the VPAP Auto or Ramp or Settling screen is displayed To scroll through items within the menu Press the Up Down key To exit out of the menu Press the Right key exit English VAuto mode S mode amp CPAP mode SETTLE 20min menu RAMP 20min menu EXHALATION MED change exit USED 00000hrs 00000 00000days MASK MIR FULL change exit SW SX3650201 T exit Figure 2 VPAP Auto Menu Series Note The Exhalation screen is only available if enabled by a clinician Preparing for Use 11 Menus with a Humidifier If the HumidAire 3i is connected to the VPAP Auto and treatment has not commenced the VPAP Auto will display one of the following screens
143. onando adequadamente O respiradouro associado m scara nunca deve ser obstru do Explica o a unidade VPAP Auto deve ser utilizada com m scaras ou conectores especiais que cont m respiradouros de modo a proporcionar a sa da de um fluxo cont nuo de ar da m scara Portas podem ser incorporadas m scara ou a conectores que estejam pr ximos da m scara Quando o dispositivo estiver ligado e funcionando corretamente o ar fresco do dispositivo elimina o ar expirado atrav s do respiradouro da mascara Contudo quando o dispositivo n o est funcionando n o fornecido ar fresco suficiente atrav s da m scara e o ar expirado pode ser novamente reinalado A reinala o do ar expirado por alguns minutos pode em certas circunst ncias provocar asfixia Isso se aplica maioria dos modelos de dispositivos PAP Na eventualidade de uma falha de energia ou avaria da m quina remova a m scara O VPAP Auto pode ser ajustado para administrar press es de at 20 cm H20 No caso improv vel de certas condi es de avaria poss vel a administra o de press es de at 30 cm H20 Se este dispositivo for utilizado com oxig nio quando n o estiver em uncionamento o fluxo do g s dever ser desligado Caso tenha permanecido ligado nessas condi es desconecte a alimenta o do g s e aguarde 60 minutos antes de ligar o dispositivo Explica o quando o dispositivo PAP n o se encontra em funcionamento e o fluxo
144. ons m dicales Usage pr vu pour la VPAP Auto Contre indications Avertissements Pr cautions Le syst me VPAP Auto Masque Oxyg ne additionnel Pr paration avant l utilisation Installation de la VPAP Auto Assemblage du masque Instructions d utilisation D but du traitement SmartStart Arr t du traitement Utilisation de la fonction d ajustement du masque Messages affich s sur l cran LCD de la VPAP Auto Modules Astuces Nettoyage et entretien Nettoyage quotidien Nettoyage hebdomadaire Nettoyage p riodique Remplacement du filtre air R parations Strat gie de d pannage CaArACI TISIQUES passas 6 para od ata a pan habe ee pales Accessoires Symboles apparaissant sur l appareil Garantie limit e N BNMNN Introduction D finitions Ce guide contient des termes et ic nes sp ciaux qui apparaissent dans la marge et ont pour but d attirer votre attention sur des informations sp cifiques importantes Un avertissement vous met en garde contre le risque de blessure Une pr caution Attention explique des mesures particuli res permettant d assurer une utilisation efficace et s re de l appareil Une remarque correspond une remarque ou information utile Fran ais Responsabi
145. ons sont les suivantes CPAP S et VAuto Indicateur de rampe mode CPAP mode S s affiche si la VPAP Auto est en mode de rampe Disparait une fois que la dur e de rampe s est coul e Indicateur d attente mode VAuto s affiche si la VPAP Auto est en mode d attente Dispara t une fois que le temps d attente s est coul Pression s r gl e s en mode CPAP il s agit de la pression de traitement fix e en centim tres d eau En mode S il s agit des pressions d expiration et d inspiration en centim tres d eau En mode VAuto il s agit des pressions EPAP et IPAP en centim tres d eau Indicateur d apn e mode CPAP mode VAuto indicateur visuel un A s affiche pour indiquer qu une apn e est en train de se produire Histogramme de pression repr sentation graphique des variations de pression Fuite fuite au masque actuelle en litres par minute Fr quence respiratoire nombre de respirations par minute Ventilation minute volume d air inspir par minute en litres par minute Instructions d utilisation 17 Volume courant volume d air inspir par respiration en millilitres par respiration Respiration phase expiration cette option s affiche dans le format type de respiration affichage de la phase type d expiration comme indiqu ci dessous p ex S TiMn Type de respiration S spontan e Affichage de la phase inspiration blanc expiration Type d expiration TiMn expir
146. ouche de d placement vers le haut ou de d placement vers le bas jusqu ce que le type de masque d sir s affiche Le tableau suivant indique le r glage qui doit tre s lectionn pour chaque type de masque Tableau 3 Options de r glage pour les diff rents types de masque R glages Masque ULTRA Masque nasal Ultra Mirage Masque nasal Ultra Mirage II MIR FULL Masque facial Mirage Liberty n Masque facial Mirage Quattro T Masque facial Ultra Mirage ira ACTIVA Masque nasal Mirage Activa SWIFT Masque narinaire Mirage Swift Masque narinaire Mirage Swift II STANDARD Masque nasal Mirage Vista Messages affich s sur l cran LCD de la VPAP Auto Votre clinicien a peut tre r gl votre VPAP Auto pour qu elle vous rappelle des choses importantes comme le moment ou vous devez remplacer votre masque le moment ou vous devez ins rer votre carte de donn es si votre appareil est activ pour la carte de donn es etc Le message de rappel s affiche sur l cran LCD et peut tre lu m me lorsque l appareil ne d livre pas de traitement Le r tro clairage de l cran LCD clignote lorsqu un message s affiche Votre clinicien peut r gler les rappels suivants sur votre cran LCD Message Description Action INSERER Peut s afficher si la Ins rez votre carte de donn es voir la CARTE fonction Carte de section H de la fiche d illustrations et suivez donn es est les instructions que votre clinicien vous
147. our mask system according to the mask user instructions Connect your mask system to the free end of the air tubing D 3 Check that the mask setting on the MASK screen is the one recommended for the mask you are using see the table in How to Select the Mask Type on page 16 The VPAP Auto is now ready for use D 4 Preparing for Use English 7 Humidifier Use Please refer to the illustration in section E of the illustration sheet and your HumidAire 3i manual WARNING The VPAP Auto is not compatible with external humidifiers HumidAire 3i humidifier The HumidAire 3i attaches to the front of the VPAP Auto to provide heated humidification No other accessories are required for its use The VPAP Auto automatically detects the presence of the HumidAire 3i No menu changes are required Please refer to the relevant user manual for details WARNING Make sure that the water chamber is empty and thoroughly dried before transporting the HumidAire 3i When using the travel bag always separate the VPAP Auto unit and the Humidaire 3i and place the HumidAire 3i in its pouch The VPAP Auto is now ready for use To start treatment see Operating Instructions on page 13 Features of the VPAP Auto The control panel of the VPAP Auto unit includes a keypad for navigating through the menus and delivering treatment LCD screen Up key Left key Right key Start Stop Key Down key Figure 1 VPAP Auto K
148. ower consumption lt 100VA maximum power consumption Housing construction Flame retardant engineering thermoplastic Environmental conditions Operating temperature 41 F to 95 F 5 C to 35 C Operating humidity 10 95 non condensing Storage and transport temperature 4 F to 140 F 20 C to 60 C Storage and transport humidity 10 95 non condensing Operating Altitude Sea level to 8500 Electromagnetic Compatibility Product complies with all applicable electromagnetic compatibility requirements EMC according to IEC60601 1 2 for residential commercial and light industry environments For further details see Guidance and Manufacturer s Declaration Electromagnetic Emissions and Immunity on page 31 Noise Level VPAP Auto CPAP mode 10 cm H 0 set pressure Measured total A weighted sound pressure level 24 dBA dB re 20 uPa Uncertainty dB re 20 uPa 2 dBA Measured values are determined according to the noise test procedure given in ISO 17510 1 Note The sum of a measured noise emission value and its associated uncertainty represents an upper boundary of the range of values that is likely to occur in measurements a Declared dual number noise emission values in accordance with ISO 4871 Air filter Two layered powder bonded polyester non woven fiber Air tubing Flexible plastic 1 x 6 6 2 m length Air outlet The 22 mm conical air outlet complies with EN 1281 1 IEC 60601 1 clas
149. pa ol 14 Uso de la funcion Ajuste de mascarilla 3 Puede usar la funci n Ajuste de mascarilla del VPAP Auto para ayudarse a obtener un ajuste adecuado Esta funci n suministra presi n de aire durante tres minutos antes del inicio del tratamiento a fin de que usted pueda verificar y ajustar el ajuste de mascarilla para minimizar las fugas Nota verifique que la configuraci n de la mascarilla en la pantalla MASCARILLA coincida con la mascarilla que usted est usando Para usar la funci n ajuste de mascarilla Col quese la mascarilla siguiendo las instrucciones para el usuario de dicha mascarilla Mantenga presionada la tecla Inicio Detenci n durante por lo menos tres segundos hasta que comience el suministro de presi n de aire Aparecer lo siguiente en el visor lo que indica que la funci n Ajuste de mascarilla est funcionando Su equipo aumentar la presi n hasta la presi n de ajuste de mascarilla y mantendr esta presi n durante tres minutos En el visor aparecer tambi n una calificaci n de estrellas del ajuste de mascarilla Consulte Tabla 2 Definiciones de la calificaci n de estrellas del ajuste de mascarilla en la p gina 15 AJUS MASC xkxxx x excel calificaci n de estrellas del ajuste de mascarilla Notas e La pantalla de calificaci n de estrellas del ajuste de mascarilla desaparecer pasados tres minutos e La funci n Ajuste de mascarilla se puede iniciar nicamente a p
150. produit 14980 circuit respiratoire 6 6 2 m gris code produit 14948 circuit respiratoire jetable transparent code produit 14912 Oxyg ne additionnel La VPAP Auto est compatible avec l oxyg noth rapie faible d bit d livr e par une source externe Lorsque de l oxyg ne additionnel est d livr un d bit fixe la concentration de l oxyg ne inhal varie en fonction des r glages de pression de la respiration du patient du masque s lectionn ainsi que du taux de fuite Cet avertissement vaut pour la plupart des appareils de pression positive Pr paration avant l utilisation Installation de la VPAP Auto 1 Placez la VPAP Auto sur une table proximit du dosseret de votre lit ATTENTION Veiller placer l appareil de fa on viter que quelqu un puisse buter dedans le faire tomber ou se prendre les pieds dans le c ble d alimentation Remarque vous pouvez galement placer la VPAP Auto par terre c t de votre lit ou dessous Veillez ce que l endroit choisi soit exempt de poussi re de literie de v tements ou de tout autre objet susceptible d obstruer l entr e d air Branchez le c ble d alimentation la prise l arri re de l appareil D 1 Branchez l autre extr mit du c ble d alimentation une prise de courant AVERTISSEMENT V rifier que le c ble d alimentation et la fiche sont en bon tat et que l quipement n est pas endommag Raccordez fermement une ext
151. r mit du circuit respiratoire la sortie d air D 2 AVERTISSEMENT Seul le circuit respiratoire ResMed peut tre utilis avec votre appareil Les circuits respiratoires d un autre type risquent de modifier la pression re ue et de r duire l efficacit de votre traitement e Lobstruction du circuit ou de l entr e d air pendant le fonctionnement risque de causer une surchauffe de l appareil En milieu hospitalier tout ordinateur personnel utilis avec votre appareil de PPC doit se trouver une distance minimale de 5 1 5 m du patient ou au moins 8 2 5 m au dessus de lui L ordinateur doit galement tre conforme la norme d essai applicable Pour les ordinateurs personnels il s agit de la norme CEI 60950 ou quivalent Assemblage du masque 1 2 Assemblez votre masque conform ment son mode d emploi Raccordez le masque l extr mit libre du circuit respiratoire D 3 V rifiez que le r glage de masque de I cran MASQUE est celui recommand pour le masque que vous utilisez voir tableau dans la section Pour s lectionner le type de masque page 18 La VPAP Auto est maintenant pr te tre utilis e D 4 Pr paration avant l utilisation Fran ais 7 Utilisation d un humidificateur Veuillez vous r f rer la section E de la fiche d illustrations et au manuel de votre HumidAire 3i AVERTISSEMENT La VPAP Auto n est pas compatible avec les humidificateurs non int gr s
152. r clinician to adjust the pressure VPAP Auto does not start when you breathe into the mask 24 Power cord not connected properly Power outlet may be faulty Breath is not deep enough to trigger SmartStart Connect power cord firmly at both ends Try another power outlet Take a deep breath in and out through the mask Problem Possible Cause There is excessive leak Solution Adjust position of mask and headgear English Caps may be missing from ports on mask Replace them Air tubing not connected properly Connect firmly at both ends Air tubing kinked or punctured Straighten or replace VPAP Auto unit does not stop when you remove your mask SmartStop is disabled Note SmartStop is not available if you are using a full face mask or if Leak Alert is enabled Enable SmartStop if possible SmartStop is enabled but the flow generator does not stop automatically when you remove your mask Incompatible humidifier or mask system being used Use only equipment as recommended and supplied by ResMed Pressure rises inappropriately Talking coughing voluntarily breath holding eg while rolling over in bed or intentionally breathing in an unusual manner Mask cushion is buzzing against the skin Cushion seated incorrectly Cushion seated incorrectly causing excessive leak Air tubing is kinked or punctured Humidifier control dial set too h
153. r fitness for a particular purpose Some regions or states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you ResMed shall not be responsible for any incidental or consequential damages claimed to have occurred as a result of the sale installation or use of any ResMed product Some regions or states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from region to region For further information on your warranty rights contact your local ResMed dealer or ResMed office R001 307 2 05 06 Limited Warranty 35 36 Index A Accessories 6 Air filter 5 24 replacing 23 Air pressure 24 Air tubing 5 cleaning 22 connect to air outlet 7 kinked 24 Aircraft 21 B Backlight LCD and keypad 10 C Cleaning daily 22 periodic 22 weekly 22 Cleaning mask 22 Components 5 D Daily cleaning 22 Data Card 26 DC 12 converter 21 Definitions 1 Down key 9 Dryness 20 Dynamic pressure characteristics 28 E Electromagnetic Compatibility 29 Error messages 26 F Features of the VPAP Auto 9 H Headgear position 24 Helpful hints 20 HumidAire 3i 8 Humidifier 6 8 cleaning 22 Humidifier use 8 English International use 21 K Keypad 5 L LCD 5 error messages 27 messages 17 Left key 10 L
154. r respiratory tract infection may require temporary discontinuation of treatment The following side effects may arise during the course of therapy with the device drying of the nose mouth or throat nosebleed bloating ear or sinus discomfort eye Irritation skin rashes chest discomfort The VPAP Auto System Please refer to the illustrations in section A of the illustration sheet Front view A 1 Shows the keypad and LCD screen and the air outlet Rear view A 2 Shows where the module attaches and the location of the air filter and power sockets Power cord A 3 Power cord to attach the VPAP Auto to the AC mains power Travel bag A 4 Air tubing A 5 The 6 6 2 m air tubing connects the VPAP Auto to your mask Mask You will also need a ResMed mask system supplied separately The following ResMed mask systems are recommended for use with the VPAP Auto Nasal Masks e Mirage Vista Nasal Mask e Ultra Mirage Nasal Mask e Ultra Mirage Nasal Mask e Mirage Activa Nasal Mask Nasal Pillows Systems Mirage Swift Nasal Pillows System e Mirage Swift Nasal Pillows System l English Full Face Masks e Mirage Liberty Full Face Mask e Mirage Quattro Full Face Mask e Ultra Mirage Full Face Mask Notes e Not all masks are available in all regions ResMed devices have been designed and manufactured to provide optimum performance using ResMed vented mask
155. ra es Configura o de Ti Max seg Coeficiente de I E m dio ltimas cinco respira es S TiMn Ti2 1s TiMx 4 0 45156 Nota os valores def s o os definidos pelo m dico Figura 5 Telas de tratamento todos os modos As telas de tratamento cont m as seguintes informa es Modo de tratamento o modo de tratamento definido pelo m dico As op es s o CPAP S e VAuto Indicador de rampa Modo CPAP modo S Apresentado se o VPAP Auto estiver em modo de rampa Este indicador deixa de ser apresentado quando o tempo de rampa chega ao fim Indicador de acomoda o Modo VAuto Apresentado se o VPAP Auto estiver em modo de acomoda o Este indicador deixa de ser apresentado quando o tempo de acomoda o chega ao fim Press o 0es definida s no modo CPAP esta tela apresenta a press o definida para o tratamento em cent metros de gua No modo S apresenta as press es de expira o e inspira o em cent metros de gua No modo VAuto apresenta as press es EPAP e IPAP em cent metros de gua Indicador de apn ia Modo CPAP modo VAuto Indicador visual que apresenta a letra A para indicar a ocorr ncia de apn ia Gr fico de barras da press o apresenta o gr fica das mudan as de press o Fuga fuga atual na m scara em litros por minuto Frequ ncia respirat ria n mero de respira es por minuto Ventila o por minuto volume de ar inalado por minuto l
156. ra o queixo Entre em contacto com seu m dico ou fornecedor de equipamento para mais informa es Ajuste da M scara O gerador de fluxo proporciona um tratamento mais eficaz quando a m scara se encontra bem ajustada e confort vel O tratamento pode ser afetado por fugas de ar Portanto importante eliminar quaisquer fugas de ar que venham a ocorrer Se tiver problemas ao tentar encontrar um ajuste confort vel para a m scara contate a cl nica do sono ou o fornecedor do equipamento Um tamanho diferente de m scara pode resolver o problema Voc tamb m pode utilizar o recurso de ajuste da m scara para colocar a m scara adequadamente Consulte Utiliza o da fun o de ajuste da m scara na p gina 14 Antes de colocar a m scara lave o rosto para remover o excesso de oleosidade facial Isso permitir um melhor ajuste e prolongar a vida til da almofada da m scara Irritagao nasal Ressecamento Voc pode sentir um ressecamento no nariz na boca e ou na garganta no decorrer do tratamento especialmente durante o inverno Em muitos casos a utiliza o de um umidificador pode aliviar o desconforto Contate seu m dico para mais informa es Corrimento ou obstru o nasal Nas semanas iniciais do tratamento voc poder sentir vontade de espirrar e ou ter corrimento ou obstru o nasal Na maioria dos casos a irrita o nasal pode ser resolvida com um umidificador Consulte seu m dico para mais informa
157. raitement malgr l infection nous vous conseillons de laver le masque et le circuit respiratoire apr s chaque utilisation Pr cautions basses pressions le d bit aux orifices de ventilation de votre masque peut s av rer insuffisant pour expulser tous les gaz expir s hors du circuit respiratoire Une r inhalation peut se produire La temp rature du d bit d air produit par cet appareil peut tre sup rieure de 11 F 6 C la temp rature ambiante Des pr cautions particuli res devront tre prises lorsque la temp rature ambiante est sup rieure 90 F 32 C En l absence d alimentation secteur CA 100 240 V CA syst matiquement utiliser un convertisseur DC 12 ResMed Le convertisseur DC 12 est vendu comme accessoire optionnel S il est fourni le module de carte de donn es ResScan ne peut tre utilis qu avec certains appareils ResMed Utiliser le module de carte de donn es ResScan s l est fourni uniquement comme indiqu dans ce manuel Remarque les avertissements et pr cautions pr c dents sont d ordre g n ral Les avertissements pr cautions et remarques sp cifiques sont donn s avec les instructions auxquelles ils se rapportent dans le manuel Effets secondaires Les patients doivent avertir leur m decin traitant en cas de douleurs thoraciques inhabituelles de maux de t te s v res ou d une dyspn e accrue Une infection aigu des voies a riennes sup rieures peut n cessiter l arr t tempor
158. rapy is going REPLACE May appear as a Press the Left Ok key to remove the FILTER reminder to message from your LCD and replace the air replace the air filter on your device filter Operating Instructions 17 Message Description Action SERVICE DUE May appear as a Press the Left Ok key to remove the reminder to return message from your LCD your device for service Customized Your clinician may Press the Left Ok key to remove the messages also set reminders message from your LCD for other reasons for example to return equipment or to calla particular person or number Modules Note Do not remove modules while power is connected to the VPAP Auto Your VPAP Auto will have one of two modules fitted to the back a blank module or a ResScan Data Card module Using a Blank Module Please refer to the illustrations in section F of the illustration sheet The blank module is a protective cover on your VPAP Auto At times you may wish to remove or attach the module for example to use another module To remove the blank module pull it off the back of the VPAP Auto to show the data communications port F 1 To attach the blank module push the blank module onto the data communications port until the module clicks into place F 2 Note To protect the data communications port always ensure there is a module attached to the back of the device Using a ResScan Data Card Module Please refer to the illustrat
159. retes por outras raz es como por exemplo devolver o equipamento ou contatar uma certa pessoa ou n mero M dulos Nota n o remova os m dulos enquanto que o VPAP Auto estiver conectado corrente el trica O VPAP Auto ter um destes dois m dulos encaixados parte de tr s um m dulo de prote o ou um m dulo para cart es de dados ResScan Como usar um m dulo de prote o Consulte as ilustra es na se o F do folheto de ilustra es O m dulo de prote o uma tampa protetora do VPAP Auto Certas vezes poder ser conveniente retirar ou conectar o m dulo por exemplo para usar um outro m dulo Instru es operacionais Portugu s Para remover o m dulo de prote o puxe o da parte de tr s do VPAP Auto para expor a porta de comunica o de dados F 1 Para conectar o m dulo de prote o empurre o sobre a porta de comunica o de dados at que se encaixe no lugar F 2 Nota para proteger a porta de comunica o de dados certifique se de manter sempre um m dulo conectado parte de tr s do dispositivo Como usar um m dulo de cart es de dados ResScan Consulte as ilustra es na se o G do folheto de ilustra es O m dulo de cart es de dados ResScan um acess rio do VPAP Auto Use um cart o de dados ResScan com o m dulo de cart es de dados para coletar dados e atualizar configura es do VPAP Auto O m dulo e o cart o permitem ao m dico um acesso mais f cil aos da
160. rjeta de datos ResScan Modo de uso Espafiol 19 Uso de un Modulo en blanco Consulte las figuras en la secci n F de la hoja de figuras El m dulo en blanco es una cubierta protectora para su VPAP Auto En determinadas situaciones tal vez desee retirar o conectar este m dulo por ejemplo para usar otro m dulo Para retirar el m dulo en blanco tire de l a fin de separarlo de la parte trasera del VPAP Auto y para que aparezca el puerto de comunicaci n de datos F 1 Para conectar el m dulo en blanco empujelo hacia el puerto de comunicaci n de datos hasta que se ajuste en su lugar por medio de un clic F 2 Nota para proteger el puerto de comunicaci n de datos verifique que en todo momento haya un m dulo acoplado en la parte trasera del equipo Uso de un M dulo Tarjeta de datos ResScan Consulte las figuras en la secci n G de la hoja de figuras El m dulo Tarjeta de datos ResScan es un accesorio del VPAP Auto Utilice una Tarjeta de datos ResScan con el m dulo Tarjeta de datos a fin de recolectar datos y actualizar las configuraciones del VPAP Auto El m dulo y la tarjeta le proporcionan a su m dico un f cil acceso a la informaci n acerca de su tratamiento y con ellos su m dico le puede suministrar a usted una nueva configuraci n para el equipo sin necesidad de que usted salga de su casa Conexi n del M dulo Para conectar el m dulo Tarjeta de datos presi nelo hacia el puerto de comunicaci n de datos en la p
161. rrup o do tratamento Utiliza o da fun o de ajuste da m scara Mensagens apresentadas no visor LCD do VPAP Auto M dulos Dicas teis Limpeza e manuten o Limpeza di ria Limpeza semanal Limpeza peri dica Substitui o do filtro de ar Manuten o Resolu o de problemas Especifica es t cnicas Acess rios S mbolos apresentados no dispositivo Garantia limitada ndice remissivo N ANNEN Introdu o Defini es Este manual cont m termos e cones especiais que aparecer o junto s margens do texto para chamar sua aten o para informa es espec ficas e importantes e Avisos alertam sobre a possibilidade de ferimentos e Precau es explicam medidas especiais a serem tomadas para uma utiliza o segura e eficaz do dispositivo e Notas s o observa es informativas ou teis Responsabilidade do usu rio propriet rio O usu rio ou propriet rio deste sistema ser o respons vel nico por quaisquer danos pessoais ou danos a propriedade resultantes de utiliza o do dispositivo em desacordo com as instru es operacionais fornecidas manuten o ou modifica es executadas a menos que em conformidade com instru es autorizadas e por pessoas autorizadas Leia este manual cuidadosamente antes de usar o dispositivo
162. rruptions 70 U 168 V it is recommended that the 30 dip in Ut 30 dip in 240V VPAP Auto device be or 25 cycles or 25 cycles powered from an uninterruptible power lt 5 U lt 12V source gt 95 dip in Ut gt 95 dip in 240V or 5 sec or 5 sec Power frequency 3 A m 3 A m Power frequency magnetic 50 60 Hz fields should be at levels magnetic field characteristic of a typical IEC 61000 4 8 location in a typical commercial or hospital environment NOTE Ut is the AC mains voltage prior to application of the test level Continued next page Guidance and manufacturer s declaration electromagnetic immunity The VPAP Auto device is intended for use in the electromagnetic environment specified below The English customer or the user of the VPAP Auto device should assure that the device is used in such an environment Immunity 1EC60601 1 2 Compliance Electromagnetic environment test test level level guidance Portable and mobile RF communications equipment should be used no closer to any part of the VPAP Auto device including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance Conducted RF 3 Vrms 3 Vrms d 1 17 VP IEC 61000 4 6 150 kHz to 80 MHz Radiated RF 10 V m 10 V m d 0 35 VP 80 MHz to 800 MHz IEC 61000 4 3 80 MHz to 2 5 GHz d 0 70 VP 800 MHz to 2 5 GHz where P is the ma
163. rso denominado SmartStart Essa fun o permite acionar automaticamente o dispositivo quando o usu rio respira com a m scara Se o m dico tiver ativado o SmartStop o dispositivo deixar de funcionar automaticamente quando o usu rio retirar a m scara Interrup o do tratamento Para parar o tratamento a qualquer momento remova a m scara e pressione a tecla Iniciar Parar ou se o m dico tiver ativado a fun o SmartStop bastar remover a m scara para encerrar o tratamento Nota o SmartStop n o funcionar se Voc tiver selecionado MIR FACIAL como tipo de m scara Seu m dico tiver ativado o alerta de fuga Instru es operacionais Portugu s 14 Utiliza o da fun o de ajuste da mascara O recurso de ajuste da m scara do VPAP Auto serve para ajud lo a colocar a m scara adequadamente Esse recurso fornece ar pressurizado por tr s minutos antes do in cio do tratamento para que voc possa verificar e ajustar a coloca o da m scara de modo a minimizar fugas Nota verifique se a configura o da tela MASCARA a recomendada para a m scara em uso Para usar a func o de ajuste da m scara Coloque a m scara da forma descrita nas instruc es do usu rio da m scara Mantenha a tecla Iniciar Parar pressionada por pelo menos tr s segundos at que a administrac o do ar pressurizado seja iniciada A imagem a seguir ser apresentada no visor LCD indicando que a fun o de ajuste da m scara se
164. s c cualquier da o o contaminaci n debida a humo de cigarrillo pipa cigarro u otras fuentes d d cualquier da o causado por el derrame de agua sobre el generador de aire o hacia su interior La garant a queda anulada si el producto se vende o revende fuera de su regi n de compra original Las reclamaciones de garant a con respecto a productos defectuosos deben ser realizadas por el consumidor original en el punto de compra Esta garant a revoca cualquier otra garant a expresa o impl cita incluso cualquier garant a impl cita de comerciabilidad o idoneidad para un prop sito en particular Algunas regiones o estados no permiten limitaciones respecto a la duraci n de una garant a impl cita por lo que es posible que lo que precede no sea aplicable en su caso ResMed no ser responsable de ning n da o incidental ni emergente que se reclame por haber ocurrido como resultado de la venta instalaci n o utilizaci n de cualquier producto de ResMed Algunas regiones o estados no permiten la exclusi n ni limitaci n de da os incidentales o emergentes por lo que es posible que lo que precede no sea aplicable en su caso Esta garant a le otorga derechos legales espec ficos y es posible que usted tenga otros derechos que pueden variar de una regi n a otra Para m s informaci n sobre los derechos que le otorga esta garant a p ngase en contacto con su distribuidor local de ResMed o con una oficina de ResMed R001 307 2 05 06
165. s de tens o Emiss es Em conformidade de cintila o flicker IEC 61000 3 3 A Classe B adequada para todas as configura es de sistema exceto quando um adaptador DC 12 usado para conectar o dispositivo VPAP Auto a um computador Nesse caso o sistema encontra se em conformidade com a Classe A A Classe A adequada para todas as instala es com exce o de resid ncias e locais diretamente conectados rede p blica de baixa tens o que fornece energia para fins dom sticos O equipamento m dico el trico necessita de precau es especiais relativas Compatibilidade Eletromagn tica EMC e tamb m precisa ser instalado e ligado de acordo com as informa es referentes a EMC contidas neste documento Avisos o VPAP Auto n o deve ser utilizado em cima por baixo ou ao lado de outro equipamento Se for necess rio utilizar o dispositivo VPAP Auto em cima por baixo ou pr ximo de outro equipamento verifique o correto funcionamento do mesmo no tipo de configura o utilizada A utiliza o de acess rios por exemplo umidificadores n o especificados neste manual n o recomendada Poder o acarretar o aumento de emiss es ou diminuir a imunidade do dispositivo VPAP Auto Guia e declara o do fabricante Imunidade eletromagn tica O VPAP Auto deve ser utilizado no ambiente eletromagn tico especi usu rio do VPAP Auto deve se certificar de que o sistema ser utiliza icado abaixo O cliente ou
166. s lembretes no visor LCD Mensagem Descri o A o INSERIR Poder ser Introduza o seu cart o de dados consulte a CART O apresentada se o se o H no folheto de ilustra es e siga as dispositivo utilizar instru es fornecidas pelo m dico Feito cart es de dados isso a mensagem desaparecer do visor LCD Pressione a tecla Esquerda OK para remover manualmente a mensagem SUBSTITUIR Poder ser Pressione a tecla Esquerda OK para M SCARA apresentada remover a mensagem do visor LCD e quando for hora de substitua a m scara por uma nova substituir a m scara 18 Mensagem Descri o A o CHAMAR Poder ser Pressione a tecla Esquerda OK para M DICO apresentada para remover a mensagem do visor LCD e contate lembr lo de entrar o m dico em contato com seu m dico p ex para falar acerca do progresso do tratamento SUBSTITUIR Poder ser Pressione a tecla Esquerda OK para FILTRO apresentada para remover a mensagem do visor LCD e lembr lo de substitua o filtro substituir o filtro de ar do dispositivo MANUTEN O Poder ser Pressione a tecla Esquerda OK para apresentada para remover a mensagem do visor LCD e mande lembr lo de levar o dispositivo para manuten o o dispositivo para manuten o Mensagens Seu m dico Pressione a tecla Esquerda OK para personalizadas tamb m poder remover a mensagem do visor LCD e mande programar o dispositivo para manuten o lemb
167. s se inicia autom ticamente Durante el copiado de los datos en el visor del VPAP Auto aparecer el mensaje Tarjeta insertada espere El copiado tarda hasta un m ximo de 30 segundos e Una vez que el copiado haya finalizado en el visor aparecer el mensaje Copia completa quitar tarjeta e Retire la Tarjeta de datos del m dulo Tarjeta de datos Una vez que aparece el mensaje Copia completa quitar tarjeta no se copian datos adicionales en la tarjeta aun si se deja insertada en el equipo Para agregar informaci n adicional a la Tarjeta de datos reins rtela y repita estos pasos 3 Retire la Tarjeta de datos Tome el extremo de la Tarjeta de datos y t rela hacia fuera del m dulo Tarjeta de datos H 3 4 Guarde la Tarjeta de datos Cuando no est en uso la Tarjeta de datos se debe guardar en su sobre de retorno postal 5 Envie la Tarjeta de datos a su m dico por correo Cuando envie la Tarjeta de datos por correo a su m dico 1 Inserte la Tarjeta de datos en el compartimento del sobre de retorno postal Doble el sobre de retorno postal 2 Coloque el sobre de retorno postal con la Tarjeta de datos en el sobre de correo y ci rrelo 3 Verifique que en el sobre de correo figuren el nombre y la direcci n de su m dico y envielo de inmediato Uso de la Tarjeta de datos para actualizar la configuraci n Si su m dico le ha dado una Tarjeta de datos con una nueva configuraci n para el equipo Con el
168. se tiver sido ativada pelo m dico Prepara o para uso Portugu s Menus com um umidificador Se o HumidAire 3i estiver conectado ao VPAP Auto e o tratamento ainda n o tiver sido iniciado o VPAP Auto apresentar uma das seguintes telas SUBIDA 20min menu 1 aqueci NIVELA 20min menu 1 aqueci Modos CPAP e S modo VAuto apresenta configura o de RAMPA apresenta configura o de ACOMODA O Figura 3 Apresenta o do Menu do Paciente com umidificador antes de iniciar o tratamento Ap s o in cio do tratamento a tela de tratamento ser exibida consulte a Figura 5 Telas de tratamento todos os modos na p gina 16 Menus com um ResLink e Oximetro Se o m dico recomendar o uso de um m dulo ResLink e o ResLink e um ox metro estiverem conectados ao VPAP Auto a apresenta o dos valores de SPO satura o de oxig nio e FC frequ ncia card aca ter prioridade Se o tratamento n o tiver sido iniciado o VPAP Auto apresentar uma das seguintes telas com ou sem umidificador conectado Antes de iniciar o tratamento SpO2 98 SUBIDA 20min 98 NIVELA 20min 98 menu FC 60 menu 1 Fc 60 menu t FC 60 Rampa m x desl Rampa m x definida Acomod m x definida ou como valor dif de zero como valor dif de zero Acomod m x desl Figura 4 Exibi o do menu com ResLink e oximetro Acesso aos menus Para percorrer e selecionar itens dentro do Menu do Paciente utilize atec
169. sification Class double insulation Type CF Note The manufacturer reserves the right to change these specifications without notice Accessories Data Card Dimensions L x W x D 2 56 x 0 87 x 0 03 65 04 mm x 22 15 mm x 0 85 mm Data Card Module Dimensions H x W x D 1 95 x 1 66 x 0 47 49 7 mm x 42 2 mm x 12 mm Note The manufacturer reserves the right to change these specifications without notice Technical Specifications 29 English 30 Symbols which Appear on the Device N Attention consult accompanying documents Y Type CF equipment Class Il equipment 4 Drip proof IPX 4 Dangerous voltage C Start Stop and Mask fit Guidance and Manufacturer s Declaration Electromagnetic Emissions and Immunity Guidance and manufacturer s declaration electromagnetic emissions English The VPAP Auto device is intended for use in the electromagnetic environment specified below The customer or the user of the VPAP Auto device should assure that the device is used in such an environment Electromagnetic Emissions test Compliance A lt environment guidance RF emissions CISPR11 Group 1 The VPAP Auto device uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emissions CISPR 11 with Class B The VPAP Auto device is s
170. sole responsibility and liability for any injury to persons or damage to property resulting from operation which is not in accordance with the operating instructions supplied maintenance or modifications carried out unless in accordance with authorized instructions and by authorized persons Please read this guide carefully before use Introduction 1 English Medical Information What the VPAP Auto Device is Intended for The VPAP Auto is indicated for the treatment of obstructive sleep apnea OSA in patients weighing more than 66 lb 30 kg It is intended for use in the hospital and home CAUTION USA ONLY Federal law restricts this device to sale by or on the order of a physician Contraindications Positive airway pressure therapy may be contraindicated in some patients with the following pre existing conditions severe bullous lung disease pneumothorax pathologically low blood pressure dehydration cerebrospinal fluid leak recent cranial surgery or trauma Warnings The entire manual should be read before using the VPAP Auto Advice contained in this manual should not supersede instructions given by the prescribing physician A patient should not connect a device to the data communication port unless instructed to do so by their health care provider or physician Only ResMed products are designed to be connected to the data communication port Connecting other devices could result in injury or dama
171. solu o de problemas 26 Responsabilidade do usu rio propriet rio 1 Responsabilidade usu rio propriet rio 1 Ressecamento 22 T tecla Direita 10 tecla Esquerda 10 tecla Iniciar Parar 9 tecla Para baixo 9 tecla Para cima 9 teclado 5 Tela de tempo Decorrido 11 Tela de acomoda o 10 Tela de m scara 14 Tela de rampa 10 Tempo de acomoda o 10 17 26 Tempo de rampa 10 17 26 tipos de m scaras 17 tomadas de energia 5 tubo de ar 5 conectar sa da de ar 7 dobrado 26 limpeza 24 U umidificador 6 limpeza 24 uso em aeronave 23 Uso internacional 23 Utiliza o 8 Utiliza o de umidificador 8 Utiliza o dos menus 10 V Viagens 23 VPAP Auto dimens es 32 manuten o 25
172. sur l cran LCD Ensuite l cran Rampe ou Attente s affiche Remarque si vous utilisez l appareil avec un HumidAire 3i veuillez vous r f rer au manuel utilisateur correspondant pour les instructions de fonctionnement 2 Mettez votre masque comme indiqu dans son mode d emploi 3 Allongez vous et placez le circuit respiratoire de mani re ce qu il puisse suivre vos mouvements pendant que vous dormez 4 Pour commencer le traitement il vous suffit de respirer dans le masque voir SmartStart page 14 L air commence s couler lentement et le d bit augmente progressivement pour atteindre la pression de fonctionnement au bout de 10 15 secondes environ Remarque si la VPAP Auto ne d marre pas automatiquement vous pouvez alors appuyer sur la touche Marche Arr t SmartStart La VPAP Auto poss de une fonction appel e SmartStart SmartStart permet a votre appareil de d marrer automatiquement lorsque vous respirez dans le masque Si votre clinicien a activ SmartStop le traitement s arr te automatiquement lorsque vous retirez votre masque Arr t du traitement Pour arr ter le traitement a tout moment retirez votre masque et appuyez sur la touche Marche Arr t ou Si votre clinicien a activ SmartStop retirez simplement votre masque pour arr ter le traitement Remarque SmartStop ne fonctionne pas si vous avez s lectionn MIR FULL comme option de masque e votre clinicien a activ l alarme
173. systems Other mask systems may be used however performance and data outputs may be affected In VAuto mode only ResMed masks are compatible for use with the VPAP Auto Your clinician needs to set up your VPAP Auto for use with your particular mask The VPAP Auto System 5 Humidifier Please refer to the illustration in section B of the illustration sheet A humidifier may be required if you are experiencing dryness of the nose throat or mouth The VPAP Auto is compatible for use with the HumidAire 3i heated humidifier B WARNING Only the HumidAire 3i is compatible for use with the VPAP Auto Please refer to Warnings on page 2 Accessories Please refer to the illustrations in section C of the illustration sheet The following accessories are available for use with the VPAP Auto ResScan Data Card C 1 e ResScan Data Card module C 2 Blank module C 3 e DC 12 converter C 4 e Air tubing 9 10 3 m C 5 Note ResMed recommends the following tubing products for use with the VPAP Auto 9 9 3 m air tubing gray PN 14980 6 6 2 m air tubing gray PN 14948 disposable air tubing clear PN 14912 Supplemental Oxygen The VPAP Auto is designed to be compatible with the use of low flow oxygen therapy provided from an external source At a fixed flow rate of supplemental oxygen flow the inhaled oxygen concentration will vary depending on the pressure settings patient breathing pattern m
174. tamente con su m dico Soluci n de problemas Espafiol 29 30 Problema Al tratar de actualizar las configuraciones por medio de una Tarjeta de datos aparece el siguiente mensaje en el visor Error configuraci n quitar tarjeta Causa posible Hay un error de datos en la Tarjeta de datos Soluci n Comun quese inmediatamente con su m dico Al tratar de actualizar las configuraciones por medio de una Tarjeta de datos el siguiente mensaje NO aparece en el visor Configuraci n correcta quitar tarjeta La configuraci n no se actualiz Comun quese inmediatamente con su m dico Especificaciones t cnicas Rendimiento Rango de la presi n de funcionamiento de 3 a 20 cm H 0 Presi n m xima suministrada en caso de fallo 30 cm H 0 Tolerancia en la medici n de la presi n 0 5 cm H 0 4 de la lectura de la medici n Tolerancia en la medici n del flujo 0 1 6 20 en la lectura la que sea mayor Caracter sticas de la presi n din mica Modo VAuto 4 a 20 cm H20 medida en la mascarilla presi n EPAP Min 4 cm H 0 presi n IPAP M x 20 cm H20 Presi n de soporte O a 10 cm H20 Modo S IPAP 5 a 20 cm H20 medida en la mascarilla EPAP 3 a 20 cm H20 medida en la mascarilla Modo CPAP 4 a 20 cm H20 medida en la mascarilla Nivel de presi n ac stica la presi n ac stica radiada est medida a lt 30 dBA a 10 cm H20 y 1 m 3 pies 3 37 pulgadas de acuerdo con la nor
175. ticos y aqu llos conectados directamente a una red de alimentaci n de baja tensi n que alimente a los edificios destinados a vivienda Un equipo m dico el ctrico requiere precauciones especiales en lo concerniente a la compatibilidad electromagn tica y debe ser instalado y puesto en funcionamiento seg n la informaci n relativa a dicha compatibilidad que se proporciona en este documento Advertencias el equipo VPAP Auto no debe utilizarse al lado de otro equipo ni montado sobre o debajo de otro equipo Si fuera inevitable dicha proximidad o el tenerlo montado sobre o debajo de otro equipo el equipo VPAP Auto deber a ser observado para verificar su normal funcionamiento en la configuraci n en la que ser utilizado No se recomienda el uso de accesorios por ej humidificadores distintos a los que se especifican en este manual Dichos humidificadores podr an provocar un aumento de las emisiones o una disminuci n de la inmunidad del equipo VPAP Auto Gu a y declaraci n del fabricante inmunidad electromagn tica El equipo VPAP Auto est dise ado para ser utilizado en el entorno electromagn tico especificado a continuaci n El cliente o usuario del equipo VPAP Auto deber asegurarse de que sea utilizado en dicho entorno Prueba de AR Nivel de Entomo jus inmunidad prueba cumplimiento electromagnetics CEI 60601 1 2 guia Descarga 6 kV por 6 kV por contacto Los suelos deben ser
176. tiel diff rentiel lectrique doit tre celle 2 kV en mode 2 kV en mode d un environnement commun commun commercial ou hospitalier typique Baisses de tension lt 5 Ut lt 12V La qualit du secteur br ves coupures de gt 95 de baisse gt 95 de baisse lectrique doit tre celle courant et variations en Ut en 240 V d un environnement de tension sur les pour 0 5 cycle pour 0 5 cycle commercial ou hospitalier lignes 40 Ut 96 V typique d alimentation CEI 61000 4 11 60 de baisse en Ut pour 5 cycles 70 Ut 30 de baisse en Ut pour 25 cycles lt 5 Ut gt 95 de baisse 60 de baisse en 240 V pour 5 cycles 168 V 30 de baisse en 240 V pour 25 cycles lt 12V gt 95 de baisse Si l utilisateur de la VPAP Auto ne peut pas supporter l interruption du traitement en cas de coupure de courant il est recommand d utiliser la VPAP Auto avec une source d alimentation ininterruptible en Ut en 240 V pour 5 sec pour 5 sec Champ magn tique 3 A m 3 A m Le niveau des champs de la fr quence d alimentation 50 60 Hz CEI 61000 4 8 magn tiques de la fr quence d alimentation doit tre caract ristique d un endroit typique dans un environnement commercial ou hospitalier typique REMARQUE Ut correspond la tension secteur CA avant l application du niveau d essai suite page suivante Guide et d claration du fabricant Immunit lectr
177. tiene autom ticamente al quitarse la mascarilla Se est utilizando un humidificador o sistema de mascarilla no compatible Utilice Unicamente el equipo recomendado y suministrado por ResMed La presi n asciende de forma inadecuada El hablar toser aguantar la respiraci n de manera voluntaria p ej al volverse en la cama o la respiraci n inusual intencional La almohadilla de la mascarilla vibra contra la piel La almohadilla no est bien asentada La almohadilla mal asentada est provocando una fuga excesiva El tubo de aire est torcido o roto Evite hablar con una mascarilla nasal puesta y respire lo m s normalmente que sea posible Ajuste el arn s para la cabeza Ajuste el arn s o vuelva a colocar la almohadilla Enderece o cambie el tubo Soluci n de problemas Espafiol 21 Problema Causa posible La escala de control del humidificador esta demasiado alta lo que resulta en una acumulaci n de agua en el tubo de aire Soluci n Gire la escala de control bajando el nivel y retire el agua del tubo de aire Aparece un mensaje de error en el visor Revisar tubo Pulse c hecho El tubo de aire no est bien conectado o est obstruido Verifique que el tubo de aire est firmemente conectado a su mascarilla y a la salida de aire en la parte delantera del VPAP Auto Una vez que haya verificado el tubo de aire pulse la tecla Inicio Detenci
178. tienen la siguiente informaci n Modo de tratamiento el modo de tratamiento configurado por su m dico Las opciones son CPAP S y VAuto Indicador de rampa modo CPAP modo S Aparece si el VPAP Auto esta en modo de rampa Una vez finalizada la rampa el indicador desaparece Indicador de adaptacion modo VAuto Aparece si el VPAP Auto esta en modo de adaptaci n Una vez transcurrido el tiempo de adaptaci n el indicador desaparece Presi n es configurada s en el modo CPAP sta es la presi n de tratamiento configurada centimetros de agua En modo S muestra las presiones de espiraci n e inspiraci n cent metros de agua En el modo VAuto muestra las presiones EPAP e IPAP centimetros de agua Indicador de apnea modo CPAP modo VAuto Indicador visual que muestra una A cuando se produce una apnea Gr fico de barra de presi n Reproducci n gr fica de los cambios de presi n Fuga Fuga actual por la mascarilla litros por minuto Frecuencia respiratoria La cantidad de respiraciones por minuto Ventilaci n minuto Volumen de aire inspirado en un minuto litros por minuto Volumen corriente Volumen de aire inhalado por respiraci n mililitros por respiraci n Respiraci n fase espiraci n Esta opci n de pantalla aparecer en el formato tipo de respiraci n pantalla de fase tipo de espiraci n por ej S TiMn Tipo de respiraci n S espont neo Pantalla de fase inspiraci n en blanco espiraci n
179. tion type TiMn expiration triggered at completion of minimum inspiration hold time TiMx expiration triggered at completion of maximum inspiration hold time C expiration triggered spontaneously within Ti Min and Ti Max Ramp Time S mode CPAP mode Ramp time is a feature which can be enabled by your clinician If you have difficulty falling asleep with full pressure select a ramp time The airflow will start very gently while you fall asleep The pressure will slowly increase to full operating pressure over the selected ramp time The clinician has set a maximum ramp time you may select any value up to the maximum Settling Time VAuto mode Settling time is a feature which can be enabled by your clinician If you have difficulty falling asleep with the VPAP Auto operating select a settling time The airflow will remain at Minimum Pressure for the period of time that you set giving you time to fall asleep After this time the VPAP Auto will be able to increase pressure in response to events The clinician will set a maximum settling time you may select any value up to the maximum How to Select the Mask Type Scroll to MASK and select Change Left key Press the Up or Down keys until you see the mask type that you require The following table shows the setting that should be selected for each mask type Table 3 Settings for mask types Settings Mask ULTRA Ultra Mirage Nasal Mask Ultra Mirage ll Nasal Mask MIR FULL Mirag
180. tortill ou perc Le r glage de l humidificateur est trop lev ce qui entra ne l accumulation d eau dans le circuit respiratoire Solution D sentortillez ou remplacez le circuit respiratoire Mettez le bouton de r glage de l humidificateur sur une valeur moindre et videz le circuit respiratoire Affichage du message d erreur V rifier tuyaux App s touche Le circuit respiratoire n est pas raccord correctement o est bloqu V rifiez que le circuit respiratoire est fermement raccord votre masque et la sortie d air situ e sur le devant de la VPAP Auto Une fois que vous avez v rifi le circuit respiratoire appuyez sur la touche Marche Arr t pour red marrer l appareil Si le message ne dispara t pas d branchez le c ble d alimentation et branchez le nouveau pour red marrer l appareil Fran ais Affichage du message d erreur ERR SISTnnnn Appel SERVICE Composant d fectueux Notez le num ro de l erreur et contactez votre service technique agr ResMed Affichage du message d erreur FUITE IMPORTANTE Ajuster masque Vous avez connu des fuites excessivement lev es pendant plus de 20 secondes cons cutives V rifiez que le circuit respiratoire est correctement raccord et que votre masque ne fuit pas excessivement Servez vous de la fonction d ajustement du masque pour vous aider mettre votre masque correctement en place Si ce messag
181. tour 2 Mettez l enveloppe de retour avec la carte de donn es dans une enveloppe postale et fermez cette derni re 3 V rifiez que les coordonn es de votre clinicien sont bien indiqu es sur l enveloppe postale et renvoyez cette derni re par la poste imm diatement Utilisation de la carte de donn es pour mettre les r glages jour Si votre clinicien vous a fourni une carte de donn es qui contient de nouveaux r glages pour votre appareil Avec l appareil en mode d attente RAMPE ou ATTENTE ins rez la carte de donn es dans la fente du module de carte de donn es La mise jour des r glages commence automatiquement Le message CARTE INSEREE Patientez SVP s affiche sur l cran LCD pendant la mise jour La mise jour peut prendre jusqu 30 secondes Le message CHARG REUSSI Retirez carte s affiche sur l cran LCD si la mise jour des r glages a r ussi Remarque ce message ne s affiche qu une seule fois Si vous ins rez la carte de donn es une nouvelle fois apr s avoir mis vos r glages jour il ne s affiche pas e Retirez la carte de donn es du module de carte de donn es La carte de donn es doit tre conserv e dans son enveloppe de retour lorsqu elle n est pas utilis e AVERTISSEMENT Si votre clinicien vous a demand d utiliser la carte de donn es pour mettre les r glages de votre appareil jour et si le message CHARG REUSSI ne s affiche pas contacter vo
182. tre clinicien imm diatement Astuces Initialement Fuites buccales Lorsque vous utilisez un masque nasal essayez de garder la bouche ferm e pendant le traitement Les fuites d air buccales peuvent diminuer l efficacit de votre traitement Si les fuites buccales vous posent probl me vous avez la possibilit d utiliser un masque facial ou une mentonni re Contactez votre clinicien ou votre prestataire de sant pour de plus amples informations Ajustement du masque L appareil d livre un traitement optimal lorsque le masque est bien ajust et confortable sans tre trop serr Le traitement peut tre affect par les fuites c est pourquoi il est important de les liminer lorsqu elles se produisent Si vous avez du mal ajuster votre masque confortablement contactez votre laboratoire du sommeil ou votre prestataire de sant Il est possible qu une autre taille de masque permette de r soudre votre probl me Vous pouvez galement vous servir de la fonction d ajustement du masque pour vous aider mettre votre masque correctement en place Voir Utilisation de la fonction d ajustement du masque page 15 Avant de mettre votre masque lavez vous le visage pour liminer tout exc s de s bum Cette pr caution permet un meilleur ajustement du masque et prolonge la dur e de vie de la bulle du masque Irritation nasale S cheresse Il est possible que vous souffriez de s cheresse nasale buccale ou de la gorge penda
183. ts portant le symbole suivant o REMARQUE 1 80 MHz et 800 MHz la plage de fr quences la REMARQUE 2 il est possible que ces directives ne s appliquent lectromagn tique d pend de l absorption et de la r flexion des s plus lev e s applique pas toutes les situations La propagation tructures des objets et des personnes l intensit des champs d metteurs fixes tels que des stations de base pour des radiot l phones cellulaires sans fil et des radios mobiles la radio amateur les radios AM et FM et la t l vision ne peut pas tre pr dite th oriquement avec pr cision Pour valuer l environnement lectromagn tique d aux metteurs RF fixes une tude lectromagn tique du site doit tre envisag e Si l intensit du champ mesur e l endroit o la VPAP Auto est utilis e d passe le niveau de conformit RF applicable figurant ci dessus il faudra s assurer du bon fonctionnement de la VPAP Auto dans un tel environnement En cas d anomalie des mesures suppl mentaires devront peut tre tre prises par exemple changement de position ou d endroit pour la VPAP Auto b Pour la plage de fr quences 150 kHz 80 MHz l intensit des champs doit tre inf rieure 10 V m Caract ristiques 37 38 Distances de s paration recommand es entre les quipements de communication RF portables et mobiles et la VPAP Auto La VPAP Auto est pr vue pour une utilisation dans
184. u Rampe ou Attente e Pour faire d filer les options d un menu Appuyez sur la touche de d placement vers le haut ou de d placement vers le bas e Pour quitter le menu Appuyez sur la touche de droite quitter Pr paration avant l utilisation Fran ais 11 12 Mode VAuto Mode S et mode CPAP RAMPE 20min menu L ATTENT 20min menu EXPIR MOY changer y quit UTIL 00000h 00000 00000jrs MASQUE MIR FULL changer quit LOG SX3650201 T quit Figure 2 Menu de la VPAP Auto Remarque l cran Expir s affiche uniquement si l acc s cet cran a t activ par un clinicien Menu avec un humidificateur Si un HumidAire 3i est raccord la VPAP Auto et si le traitement n a pas commenc l un des crans suivants s affiche sur l cran LCD de la VPAP Auto RAMPE 20min menu f chauff ATTENT 20min menu chauff Modes CPAP et S Mode VAuto affiche le param tre RAMPE affiche le param tre ATTENTE Figure 3 Menu Patient avec un humidificateur avant le d but du traitement Apr s le d marrage du traitement l cran de traitement s affiche voir Figure 5 Ecrans de traitement tous les modes page 17 Menu avec un ResLink et un oxym tre Si votre clinicien vous a recommand d utiliser un ResLink et si le ResLink et un oxym tre sont connect s la VPAP Auto alors la SpO saturation en oxyg ne et le RC rythme
185. uitable for serial adapter use in all establishments including domestic establishments and those RF emissions CISPR 11 with Class B directly connected to the public low USB adapter voltage network that supplies buildings used for domestic purposes Harmonic Emissions Class A IEC 61000 3 2 Voltage Fluctuations Flicker Complies Emissions IEC 61000 3 3 Class B for all system configurations except when a Res Auto device powered from a DC 12 adapter in which case Link with oximeter is attached to a VPAP he system is Class A compliant Class A is suitable for use in all establishments other than domestic and those directly connected to a low voltage power supply network which supplies buildings used for domestic purposes Medical Electrical Equipment needs special precautions regarding EMC and needs to be installed and put into service according to EMC information provided in this document Warnings The VPAP Auto device should not be used adjacent to or stacked with other equipment If adjacent or stacked use is necessary the VPAP Auto device should be observed to verify normal operation in the configuration in which it will be used The use of accessories eg humidifiers other than those specified in this manual is not recommended They may result in increased emissions or device decreased immunity of the VPAP Auto Technical Specifications 31 32 Guidance and manufacturer s declaration electrom
186. ujours en place R parations ATTENTION Ne pas tenter d ouvrir le bo tier de la VPAP Auto II ne contient aucune pi ce pouvant tre entretenue par l utilisateur Vinspection et les r parations doivent tre effectu es par un technicien agr Vous ne devez en aucun cas essayer d entretenir ou de r parer l appareil vous m me Ce produit VPAP Auto doit tre inspect par un service technique agr ResMed 5 ans apr s la date de fabrication Avant cette date l appareil devrait assurer un fonctionnement fiable et s r condition qu il soit utilis et entretenu conform ment aux instructions fournies par ResMed Les informations concernant la garantie ResMed sont fournies avec l appareil lors de sa livraison initiale Comme avec tous les appareils lectriques si vous constatez un d faut quelconque vous devez faire v rifier l appareil par un service technique agr ResMed Si vous pensez que votre appareil ne fonctionne pas correctement voir Strat gie de d pannage page 27 Strat gie de d pannage En cas de probl me reportez vous aux suggestions suivantes Si le probleme persiste contactez votre prestataire de sant ou ResMed N essayez pas d ouvrir l appareil Probl me Aucun affichage Cause possible l alimentation n est pas connect e Solution V rifiez que le c ble d alimentation correct est branch a votre VPAP Auto et que l interrupteur de la prise de courant le cas ch
187. un environnement dans lequel les perturbations radio lectriques par radiation sont contr l es Le client ou l utilisateur de la VPAP Auto peut contribuer la pr vention des perturbations lectromagn tiques en respectant les distances minimales recommand es ci dessous pour la s paration entre les quipements de communication RF portables et mobiles metteurs et la VPAP Auto en fonction de la puissance maximale de sortie de l quipement de communication Distance de s paration en fonction de la fr quence de l metteur m Puissance nominale de sortie maximale de 150 kHz a 80 MHz 80 MHz a 800 MHz 800 MHz a 2 5 GHz l metteur d 1 17 VP d 0 35 VP d 0 7 VP W 0 01 0 17 0 04 0 07 0 1 0 37 0 11 0 22 1 1 17 0 35 0 7 10 3 69 1 11 2 21 100 11 70 3 50 70 Pour les metteurs avec une puissance nominale de sortie maximale ne figurant pas dans le tableau ci dessus la distance de s paration recommand e d en m tres m l quation applicable la fr quence de l metteur o maximale de l metteur en watts W indiqu e par le peut tre d termin e l aide de P correspond la puissance nominale de sortie abricant de l metteur REMARQUE 1 80 MHz et 800 MHz la distance de s paration pour la plage de fr quences la plus lev e s applique REMARQUE 2 il est possible que ces directives ne s appliquent pas toutes les situations La propagation lectr
188. ure and comfortable fit Once you have a secure and comfortable fit check your mask fit star rating on the LCD screen Table 2 explains the mask fit star ratings Note lf there is another person nearby to check your mask fit star rating you can adjust your mask mask cushion and headgear while lying down Table 2 Definitions of Mask Fit Star Rating Star rating Definition bis Excellent Vie Very good Fe Good Rs Adjust mask Adjust mask Adjust mask 4 After three minutes the pressure reverts to the set pressure and treatment will begin If you do not wish to wait three minutes hold down the Start Stop key for at least three seconds to start treatment immediately If you press the Start Stop key for less than three seconds the device will return to standby mode the RAMP or SETTLING screen is displayed English CPAP mode S mode VAuto mode First screens only display if Ramp or Settling are selected Mode Ramping Indicator Mode Ramping Indicator Mode Settling Indicator Set EPAP pressure EPAP Set IPAP pressure IPAP CPAP pressure VA SETL 8 0 11 0 A gt gt gt gt PS 3 0 Pressure Support Apnea Indicator P Leak Minute ventilation L min SAMA SAR Respiratory rate bpm Tidal volume mL Top row VAuto and S mode only Ti Max setting sec Breath phase expiration TIMO TiN Fate pte Average l E ratio last 5 breaths Average inspiration time
189. uxo D 1 Conecte a outra extremidade do cabo de energia a uma tomada da rede el trica AVISO Certifique se de que o cabo de energia e o plugue est o em boas condi es e de que o equipamento n o se encontra danificado Conecte uma das extremidades do tubo de ar firmemente sa da de ar da unidade D 2 AVISO S use tubos de ar ResMed com seu gerador de fluxo A utiliza o de tipos de tubos diferentes pode alterar a press o real recebida reduzindo assim a efic cia do tratamento A obstru o do tubo ou da entrada de ar durante o funcionamento do dispositivo pode acarretar o superaquecimento do mesmo No ambiente cl nico qualquer computador pessoal usado com o sistema CPAP deve estar a pelo menos 1 5 m 5 p s de dist ncia do paciente ou 2 5 m 8 p s acima dele O computador tamb m deve estar em conformidade com a norma de testes relevante No caso de computadores pessoais a norma internacional a IEC 60950 ou equivalente Monte a m scara Monte seu sistema de m scara de acordo com as instrucdes do usuario Conecte seu sistema de m scara extremidade livre do tubo de ar D 3 Verifique se a configura o de m scara na tela M SCARA a recomendada para a m scara em uso consulte a tabela Como selecionar o tipo de mascara na p gina 17 Prepara o para uso Portugu s 1 O VPAP Auto j est pronto para ser utilizado D 4 Utiliza o do umidificador Consulte a ilustra
190. vo permanece em EPAP m n com uma press o inspirat ria determinada pelo Suporte de press o acima do EPAP min Consulte Tempo de acomoda o na p gina 17 O tempo de acomoda o pode ser alterado em incrementos de cinco minutos de DESL a um tempo de acomoda o m ximo definido pelo m dico atrav s da tecla Para cima Para baixo Menus O menu permite ver detalhes sobre a vers o do software e o tempo de utiliza o do VPAP Auto A tela de tempo Decorrido apresenta o total de horas de utiliza o do dispositivo desde a ltima redefini o executada pelo m dico A tela tamb m exibe o n mero total de dias que o VPAP Auto foi utilizado em rela o ao n mero de dias dispon veis para uso A tela SW apresenta a vers o atual de software que foi instalada no VPAP Auto Figura 2 apresenta um resumo da s rie de menus padr o do VPAP Auto e Para acessar os menus do VPAP Auto Pressione a tecla Esquerda menu enquanto o VPAP Auto exibe a tela Rampa ou Acomoda o Para percorrer os itens de um menu Pressione a tecla Para cima Para baixo e Para sair do menu Pressione a tecla da Direita sair modo VAuto modo S e modo CPAP NIVELA 20min menu SUBIDA 20min menu y EXPIRA O M D alterar sair USADO 00000hrs 00000 00000dias M SCARA MIR FULL alterar sair VS SX3650201 T sair Figura 2 S rie de menus do VPAP Auto Nota a tela Expira o s ficar dispon vel
191. ximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey should be less than the compliance level in each frequency range Interference may occur in the vicinity of equipment marked with the following symbol C NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These gu absorption and ref idelines may not apply in all situations Electromagnetic propagation is affected by ection from structures objects and people Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the VPAP Auto device is used exceeds the applicable RF compliance level above the VPAP Auto device should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as reorienting or relocating the VPAP Auto device b Over the frequency range 150 kHz to 80 MHz field strengths should be less than 10 V m Technical Specific