Home

gas emergency service telephone number

image

Contents

1. This Carbon Monoxide Alarm is NOT e A substitute for either a smoke alarm or a combustible gas detector e To be seen as a substitute for the proper servicing of fuel burning appliances or the sweeping of chimneys e To be used on an intermittent basis or as a portable detector for the spillage of combustion products from fuel burning appliances or chimneys CAUTION This Carbon Monoxide alarm is designed for indoor use only Do not expose to rain or moisture Do not knock or drop the unit Do not open or tamper with the unit as this could cause malfunction The alarm will not protect against the risk of Carbon Monoxide poisoning when the battery has drained IMPORTANT Carbon Monoxide is produced by the incomplete combustion of fuels such as wood charcoal coal heating oil paraffin petrol natural gas propane butane etc e ideally it is recommended that a Carbon Monoxide alarm should be installed in or near to every room that has a fuel burning appliance such as any gas fires central heating boiler room heaters water heaters cookers grills etc This alarm should only be installed by a competent person Ensure that the audible alarm can be heard by all those who are intended to hear it This product should not be used if any fault signals are given Seek medical help if it is suspected that a member of the household is suffering from Carbon Monoxide poisoning If further details are required whic
2. Uma unidade Um kit de fixa o Um manual de instru es ser afectado por correntes de ar por exemplo extractores ou ventiladores e Onqe a circula o do ar para unidade fique obstru da por cortinas ou mobllia Onde se possa acumular sujidade ou p fazendo com que o sensor bloqueie e deixe de funcionar Numa zona onde a temperatura possa descer abaixo dos 10 C ou subir acima dos 40 C Onde possa ser facilmente deitado abaixo danificado ou onde possa ser inadvertidamente retirado e N o pinte a unidade ou permita que as passagens para g s CO fiquem bloqueadas por sujidade gordura ou outras subst ncias FUNCIONAMENTO DO ALARME Funcionamento Normal Quando n o existir Mon xido de Carbono a luz verde de funcionamento ir ficar intermitente uma vez por minuto Durante o seu funcionamento normal a unidade executa um auto teste a cada minuto Estado do Alarme Quando a unidade detecta Mon xido de Carbono esta ir emitir o sinal de alarme de forma cont nua A luz de alarme vermelha ir ficar intermitente e o dispositivo sonoro ir soar aproximadamente 5 vezes por segundo Assim que a unidade esteja em alarme h j 30 minutos o sinal de alarme completo ser dado uma vez a cada minuto Sinal de Alarme O alarme de Mon xido de Carbono pode ser distinguido de alarmes de detec o de fumo uma vez que emite o sinal C O em c digo morse 5 por segundo Funcionalidade de Sil n
3. 5 sons por 1 segundo 5 sons por 1 segundo por minuto 5 luzes por 1 segundo 5 sons por 1 segundo 1 luz verde intermitente por minuto 2 sons por minuto e luz intermitente amarela aby J N Amarelo 1 som por minuto e luz intermitente amarela N 71 AN Amarelo Uma vez activada e testada veja utilizar o alarme a unidade pode ser pendurada no perno de fixa o saliente utilizando um dos orif cios indicados na parte de tr s da unidade pelas linhas mostradas UTILIZAR O ALARME Para activar a unidade puxe a tira de activa o na parte lateral da unidade As luzes verde e vermelha ir o ficar intermitentes por breves instantes e o dispositivo sonoro ir emitir um breve som Prima o bot o de teste e mantenha o premido durante 5 segundos e verifique que a luz vermelha fica intermitente e o dispositivo sonoro soa A unidade est agora a funcionar e pronta para ser utilizada ISEN O DE RESPONSABILIDADE Este alarme de Mon xido de Carbono foi concebido para o alertar de um poss vel perigo causado por g s de Mon xido de Carbono N o foi concebido para solucionar um problema de Mon xido de Carbono nem para localizar uma fonte espec fica de Mon xido de Carbono A Honeywel n o pode ser respons vel pelo pagamento de qualquer investiga o de Mon xido de Carbono ou chamada de servi o levada a cabo ou organizada em resposta a um alarme GARANTIA O
4. gas natural propano butano etc e Idealmente se recomienda instalar la alarma detectora de Mon xido de Carbono cerca de o en cada estancia que tenga un aparato de combusti n como chimeneas a gas calderas para calefacci n central estufas calentadores de agua cocinas parrillas etc e Esta alarma s lo la debe instalar un t cnico cualificado e Aseg rese de que la alarma sonora pueda ser o da por todas aquellas personas a las que va destinada e Este producto no se debe utilizar si se detecta alguna se al de fallo e Solicite ayuda m dica si sospecha que alguna de las personas en la vivienda sufre intoxicaci n por Mon xido de Carbono e Si requiere informaci n adicional que no aparece en este manual p ngase en contacto con Honeywell Este paquete incluye Una unidad Un kit de fijaci n Un manual de instrucciones EFECTOS DE INTOXICACI N POR MON XIDO DE CARBONO El Mon xido de Carbono se combina con la hemoglobina de la sangre y reduce la cantidad de ox geno que circula por el organismo 200ppm Leves dolores de cabeza cansancio v rtigo y n useas despu s de 2 o 3 horas 400ppm Dolor de cabeza frontal en 1 o 2 horas peligro de vida o muerte despu s de 3 horas 800ppm V rtigo n useas y convulsiones a los 45 minutos P rdida de conocimiento a las 2 horas Muerte a las 2 o 3 horas 1600ppm Dolor de cabeza v rtigo y n useas a los 20 minutos Muerte al cabo de 1 hora 6400ppm Dolor d
5. limitato si consiglia di osservare le seguenti indicazioni al fine di scegliere la posizione migliore e Installare un dispositivo nelle camere da letto che ospitano apparecchi a combustione Installare un dispositivo negli ambienti che contengono un apparecchio senza condotto di scarico dei fumi o con scarico aperto Installare un dispositivo negli ambienti in cui si soggiorna a lungo ad esempio in salotto In un monolocale installare il dispositivo il pi possibile lontano dall angolo cottura e il pi possibile vicino alla zona notte In locali poco utilizzati come un locale caldaia installare il dispositivo immediatamente all esterno in modo da udire facilmente l allarme INSTALLAZIONE DEL DISPOSITIVO Il dispositivo si pu appoggiare su un piano o montare a parete con i tasselli in dotazione INSTALLAZIONE A PARETE Individuare una posizione idonea per l installazione vedere Dove installare l allarme e Collocazioni sconsigliate placchetta montaggio Opzione 1 Placchetta di montaggio speciale con chiodo di fissaggio E d in dotazione Inserire il chiodo nella placchetta chiodo di Con un martello piantare il chiodo parete fissaggio nel muro senza forzare eccessivamente Rawplug O e controllando che la placchetta non risulti eccessivamente aderente m alla parete vite Opzione 2 Vite e tassello a parete espansione NON forniti Se la parete troppo dura e no
6. o emette un segnale di guasto due trilli al carbone olio per riscaldamento paraffina benzina gas naturale propano butano ecc e Teoricamente si consiglia di installare un allarme per Monossido di Carbonio all interno o vicino a ogni locale che ospiti un apparecchio a combustione come cucine a gas caldaie per riscaldamento centralizzato stufe scaldabagno piastre di cottura griglie ecc e dispositivo deve essere installato solo da personale qualificato e Controllare che l allarme sonoro possa essere percepito da tutte le persone che lo devono sentire e Non usare il prodotto se sembra essere guasto e n caso di sospetto avvelenamento da Monossido di Carbonio richiedere l intervento del medico e Per eventuali informazioni che non dovessero comparire sul manuale contattare Honeywell La confezione contiene Un dispositivo di allarme Un kit di fissaggio Un manuale di istruzioni Non installare il dispositivo e All esterno del fabbricato e Dentro o sotto un pensile e Inuna zona molto umida ad esempio una stanza da bagno e Direttamente sopra un lavello o un piano di cottura e In prossimit di una porta o di una finestra o in punti soggetti a correnti d aria ad esempio accanto ad aspiratori o scarichi d aria e In punti dove il flusso dell aria diretto al dispositivo potrebbe essere bloccato da tendaggi o mobili e In punti dove lo sporco o la polvere potrebbero posarsi sul sensore e bloccarne
7. arranged in response to an alarm GUARANTEE We guarantee your new Carbon Monoxide alarm for six years from the date of purchase or until the expiry date on the front of the unit whichever occurs first under normal use and service to be free from defects in materials and workmanship During this period we will at our discretion repair or replace any part of the Carbon Monoxide alarm which is found to be defective in either materials or workmanship providing this occurs under normal use and service We shall however be under no obligation to repair or replace units which are found to be defective in any way due to damage neglect unreasonable use or which have been tampered with or found to have been dismantled Should a problem arise with your detector please contact your supplier If you have further problems please contact Honeywell Analytics helpline direct on 44 0 1202 645577 If units need to be returned send them in suitable packaging along with proof of purchase to CO Returns Honeywell Analytics 4 Stinsford Road Nuffield Industrial Estate Poole BH17 ORZ An accompanying letter should state clearly any problem with the Carbon Monoxide alarm This guarantee does not affect your statutory rights Register your detector at www sfdetection com Find out more www honeywellanalytics com Contact us UK customer service centre Technical Services Honeywell Analytics Ltd EMEAI HAexpertOhoneywell com 4 Stin
8. bateria n o substitu vel No final da vida til da unidade se tiver alguma preocupa o relativamente elimina o segura da unidade bateria contacte o seu centro de reciclagem local ou a linha de apoio da Honeywell impressa neste manual fN AD Se a unidade activar o alarme proceda da seguinte forma Abra todas as portas e janelas para ventilar a zona e permitir que o Mon xido de Carbono disperse Este produto cumpre as Directivas Europeias de Baixa Tens o 2006 95 CE e Compatibilidade Electromagn tica 2004 108 CE A Declara o de Conformidade dos fabricantes completa pode ser consultada no seguinte site www honeywellanalytics com Sempre que poss vel desligue todos os aparelhos a combust vel e deixe de os utilizar Evacue a propriedade deixando as portas e janelas abertas Ligue para o fornecedor de g s ou de outro combust vel utilizando o n mero de emerg ncia e explique o problema Mantenha o n mero de telefone num local onde seja f cil encontr lo N o volte a entrar na propriedade at que o alarme tenha parado Obtenha imediatamente ajuda m dica para qualquer pessoa que esteja a sofrer dos efeitos de envenenamento por Mon xido de Carbono como dores de cabe a n useas etc e diga que suspeita de um envenenamenteo por Mon xido de Carbono N o utilize novamente os aparelhos que queimam combust vel at que estes tenham sido inspeccionados e seja autorizada a sua utiliza o por uma pe
9. colocar o alarme suporte Op o 1 Suporte Especial com Perno de Fixa o fornecido Introduza o perno de fixa o no suporte d Com um martelo bata suavemente o perno de fixa o contra a parede perno de fixa o certificando se de que o suporte n o parede Rawplug martelado contra a parede com 5mm demasiada for a Opc o 2 Parafuso e bucha iii N O fornecido parafuso Se a parede demasiado dura para parede utilizar um pino de fixa o utilize um parafuso com cabe a redonda N 4 e Rawplug Manuale di istruzioni H450EN Honeywell Carbon Monoxide Detector HAS0EN See Imporiam Information on inside of ibd Sinos Light Greer Ok Yoloa F Raplace Und by November 2018 Honeywell T Ensi Dispositivo di allarme per Monossido di Carbonio Manuale d uso 156 3495 010 EN50291 2001 INTRODUZIONE Grazie per avere acquistato questo LED rosso di allarme LED di stato verde Ok giallo guasto dispositivo di allarme studiato per Pulsante rilevare la presenza del Monossido test di Carbonio Questo manuale fornisce tutte le informazioni necessarie all installazione e all uso del dispositivo di allarme per Mon Awisatore acustico PRIMA DI USARE Il DISPOSITIVO LEGGERE CON LA MASSIMA ATTENZIONE E INTEGRALMENTE IL CONTENUTO DI QUESTO MANUALE DI ISTRUZIONI CONSERVARE IL MANUALE IN UN POSTO SICURO PER POTERLO CONSULTARE IN FUTU
10. seu novo alarme de Mon xido de Carbono tem uma garantia de seis anos a partir da data de aquisi o at data de expira o na parte frontal da unidade a que ocorrer primeiro em utiliza o e manuten o normais sem defeitos de material e de fabrico Durante este per odo iremos de acordo com os nossos crit rios reparar ou substituir qualquer pe a do alarme de Mon xido de Carbono que tenha defeitos de material ou de fabrico desde que tal aconte a em condi es normais de utiliza o e manuten o Contudo n o temos qualquer obriga o de reparar ou substituir unidades que tenha defeitos devido a danos neglig ncia utiliza o n o adequada ou que tenham sido alteradas ou desmanteladas Se surgir algum problema com o seu detector contacte o seu fornecedor Em anexo deve seguir uma carta descrevendo claramente qualquer problema com o alarme de Mon xido de Carbono Esta garantia n o afecta os seus direitos legais Registe o seu detector em www sfdetection com Para mais informa es www honeywellanalytics com Contacte Europa M dio Oriente frica e ndia Life Safety Distribution AG Weiherallee 11a CH 8610 Uster Switzerland Tel 41 0 44 943 4300 Fax 41 0 44 943 4398 gasdetectionOhoneywell com II LED di stato lampeggia a intervalli di circa 1 minuto per segnalare che il dispositivo funziona corret tamente In caso di guasto il LED diventa giallo e lampeggia in sincrono con l emissione
11. to put the alarm and where not to put the alarm eah Pad Option 1 Special Mounting Pad with Fixing Pin supplied 4 Place the fixing pin through the i mounting pad Using a hammer Fixing Pin gently knock the fixing pin into the wall Wall l ensuring that the mounting pad is not hammered too firmly into the wall Rawplug ll Option 2 Screw and wall plug NOT supplied If the wall is too hard to use the fixing as pin use a No 4 round head screw and Wall Rawplug Once activated and tested see using the alarm the unit can be hung on the protruding fixing pin using one of the keyholes indicated on the back of the unit by the lines shown USING THE ALARM To activate the unit pull out the activation strip at the side of the unit The green and red lights will flash briefly and the buzzer will sound a short chirp Press the test button and hold for up to 5 seconds and check that the red light flashes and the buzzer sounds The unit is now operating and is ready for use DISCLAIMER This Carbon Monoxide alarm is designed to alert you to a potentially dangerous build up of Carbon Monoxide gas It is not designed to remedy a Carbon Monoxide problem nor to locate a specific source of Carbon Monoxide Honeywell shall not be liable to pay for any Carbon Monoxide investigation or service call carried out or
12. ALARM SOUNDS If the unit raises an alarm proceed as follows e Open all doors and windows to ventilate the area and allow the Carbon Monoxide to disperse e Where possible turn off all fuelled appliances and stop using them e Evacuate the property leaving the doors and windows open e Ring the gas or other fuel supplier on their emergency number and explain the problem Keep the telephone number in a prominent place e Do not re enter the property until the alarm has stopped e Get medical help immediately for anyone suffering from the effects of Carbon Monoxide poisoning such as headaches nausea etc and advise that Carbon Monoxide poisoning is suspected Do not use the fuel burning appliances again until they have been checked and cleared for use by a competent person according to national regulations GAS EMERGENCY SERVICE TELEPHONE NUMBER 0800 111 999 Contact Numbers for OTHER FUEL Appliances OIL USERS Contact OFTEC on 0845 658 5080 SOLID FUEL USERS Contact HETAS on 0800 600 000 Please note these numbers are only available during normal office hours Gas appliances should be checked for safety annually by a Gas Safe registered engineer To find a registered engineer in your area call Gas Safe Register on 0800 408 5500 or look on the website www gassaferegister co uk User Manual also available in Braille A Carbon Monoxide safety information sheet is available in Punjabi Urdu Bengali Gujarati and
13. ANTES DE UTILIZAR LA ALARMA GUARDE EL MANUAL EN UN LUGAR SEGURO PARA PODERLO CONSULTAR EN FUTURAS OCASIONES PRESTE ESPECIAL ATENCI N A LAS ADVERTENCIAS DE SEGURIDAD CEDA EL MANUAL A LOS USUARIOS POSTERIORES DE LA ALARMA ADVERTENCIA ESTA ALARMA DE MON XIDO DE CARBONO PUEDE NO PROTEGER A PERSONAS QUE POR MOTIVOS DE EDAD EMBARAZO O PROBLEMAS DE SALUD SEAN M S SENSIBLES A LA EXPOSICI N AL MONOXIDO DE CARBONO EN CASO DE DUDA CONSULTE A SU M DICO Esta alarma detectora de Mon xido de Carbono NO e Debe considerarse un sustituto de una alarma de humos o de un detector para gas combustible e Debe considerarse como un sustituto del mantenimiento adecuado de los aparatos de combusti n o de la limpieza de chimeneas e Debe utilizarse de forma intermitente ni como un detector port til para el derrame de productos desde aparatos de combusti n o chimeneas A PRECAUCI N Esta alarma detectora de Mon xido de Carbono est dise ada para utilizarse exclusivamente en interiores No debe exponerse a la lluvia ni a la humedad No debe golpearla ni dejarla caer No abra ni manipule la unidad ya que ello podr a causar un mal funcionamiento La alarma no proteger del riesgo de intoxicaci n por Mon xido de Carbono si la pila est agotada IMPORTANTE e El Mon xido de Carbono se produce por la combusti n incompleta de materias como la madera carb n vegetal carb n gas leo de calefacci n parafina gasolina
14. Hindi For copies please call Honeywell Analytics on 01202 645577 DECLARATION OF CONFORMITY This product complies with European Directives for Low voltage 2006 95 EC and Electromagnetic Compatibility 2004 108 EC The manufacturers full Declaration of Conformity may be found at the following website address www honeywellanalytics com KM 565387 BS EN 50291 2001 IN WHICH ROOM TO PUT THE ALARM Ideally an alarm should be fitted in every room that contains a fuel burning appliance However if there is more than one appliance and the number of units is limited the following points should be taken into consideration when deciding on the best location e Ifthere is an appliance in a room where people sleep a unit should be placed in that room A unit should be located in a room containing a flueless or open flued appliance If there is an appliance in a room which people use a lot such as a sitting room a unit should be placed in that room In a bedsit the unit should be placed as far away from the cooking appliance as possible but near to where the person sleeps If the appliance is in a room not normally used such as a boiler room the unit should be placed just outside the room so that the alarm will be heard more easily INSTALLING THE ALARM The unit can either be free standing or wall mounted using the fixings provided WALL MOUNTING INSTALLATION Find a position to install the unit see where
15. Instruction Manual H450EN Honeywell Carbon Monoxide Detector HAS0EN Se important irforrea iton on meide 04 1d Status Light Gerson C Tolimy Faut Roplaca Unit by EH50291 2001 Mowembar DME Honeywell Carbon Monoxide Alarm User Manual 156 3495 010 EN 50291 2001 INTRODUCTION Thank you for purchasing this Red alarm which is designed to Test Alarm Status Light detect the presence of Carbon Button Light Green Ok Yellow Fault Monoxide This manual contains information on the installation and operation of the Carbon Monoxide alarm The status light flashes green at approximately 1 minute intervals to indicate that the unit is operating correctly This will change to a yellow flash synchronised with chirp if a fault arises The red alarm light will flash continuously and the buzzer will sound if Carbon Monoxide is present The unit is suitable for use in areas where cooking and heating appliances burn fuels such as wood charcoal coal coke oil petrol gas etc WHAT IS CARBON MONOXIDE Carbon Monoxide CO is a highly poisonous gas which is released when fuels are burnt It is invisible has no smell and is therefore very difficult to detect with the human senses The first warning symptoms that CO is present in the air are usually headaches and nausea Under normal operating conditions in a room where fuel burning appliances are well maintained and correctly ventilated the amount of Carbon Mon
16. RO PRESTARE PARTICOLARE ATTENZIONE ALLE AVVERTENZE DI SICUREZZA CONSEGNARE IL MANUALE A QUALSIASI PERSONA FACCIA USO DEL DISPOSITIVO AVVERTENZE QUESTO DISPOSITIVO DI ALLARME PER MONOISSIDO DI CARBONO POTREBBE NON ESSERE SUFFICIENTE A PROTEGGERE PERSONE CON UN MAGGIORE COEFFICIENTE DI RISCHIO AD ESEMPIO ANZIANI DONNE IN GRAVIDANZA O SOGGETTI AFFETTI DA PATOLOGIE PARTICOLARI IN CASO DI DUBBIO CONSULTARE IL MEDICO CURANTE Questo dispositivo di allarme per Monossido di Carbonio e NON sostituisce un allarme antifumo o un rivelatore di gas combustibili e NON sostituisce la corretta manutenzione degli apparecchi a combustione n la pulizia dei camini e NON si deve usare a intermittenza o come rivelatore portatile per segnalare le perdite di prodotti della combustione da apparecchi o camini PRECAUZIONI Questo dispositivo di allarme per Monossido di Carbonio destinato solo ad ambienti chiusi Non esporlo alla pioggia o all umidit Non lasciarlo cadere o colpirlo in altro modo Non aprirlo o manometterlo queste operazioni potrebbero provocare malfunzionamenti Il dispositivo non protegge dal rischio di avvelenamento da Monossido di Carbonio se la batteria scarica IMPORTANTE e Il Monossido di Carbonio un prodotto della combustione EFFETTI DELL AVVELENAMENTO DA MONOSSIDO DI CARBONIO Il Monossido di Carbonio si lega all emoglobina del sangue e riduce la quantit di ossigeno in circolo nell or
17. VO Per attivare il dispositivo tirare la striscia che sporge dal fianco LED verde e rosso lampeggiano per un breve intervallo e l awisatore acustico emette un piccolo trillo Premere il pulsante Test e tenerlo premuto per 5 secondi controllando che il LED rosso lampeggi e che l avvisatore acustico suoni A questo punto il dispositivo pronto per l uso ESCLUSIONE DI RESPONSABILITA Questo allarme per Monossido di Carbonio concepito per segnalare un accumulo di Monossido di Carbonio potenzialmente pericoloso Non serve per risolvere problemi legati a perdite di Monossido di Carbonio n a localizzare una fonte di provenienza specifica di questo gas Honeywell non sosterr le spese di interventi finalizzati ad individuare e ricercare fughe di Monossido di Carbonio svolti o disposti in conseguenza di un allarme GARANZIA In condizioni d impiego e servizio normali questo dispositivo di allarme per Monossido di Carbonio garantito contro difetti di materiale e fabbricazione per sei anni a partire dalla data di acquisto oppure fino alla data di scadenza indicata sulla parte frontale a seconda dell evento che si verifica per primo Durante il periodo di garanzia il produttore si impegna a riparare o sostituire a propria discrezione qualsiasi componente del dispositivo di allarme per Monossido di Carbonio che presenti difetti di materiale o fabbricazione a condizione che tali difet
18. a en la parte frontal de la unidad lo que se produzca antes en condiciones de uso y servicio normales frente a defectos de material o fabricaci n Durante este per odo repararemos o sustituiremos a nuestra discreci n cualquier componente de la alarma detectora de Mon xido de Carbono que presente defectos de material o de fabricaci n siempre que stos se produzcan en condiciones de uso y servicio normales Sin embargo no estaremos obligados en modo alguno a reparar o sustituir las unidades en las que se detecte alg n defecto debido a da os negligencia uso inadecuado o que se hayan manipulado o desmontado Debe un problema surge con su detector contacta por favor a su suministrador Se debe incluir una carta en la que se explique claramente cualquier problema que presente la alarma detectora de Mon xido de Carbono Esta garant a no afecta a sus derechos legales Registre su detector en www sfdetection com Para m s informaci n www honeywellanalytics com Centros de contacto y atenci n al cliente Europa Oriente Medio frica e India Life Safety Distribution AG Weiherallee 11a CH 8610 Uster Switzerland Tel 41 0 44 943 4300 Fax 41 0 44 943 4398 gasdetectionOhoneywell com Am ricas Honeywell Analytics Inc 405 Barclay Blvd Lincolnshire IL 60069 USA Tel 1 847 955 8200 Toll free 1 800 538 0363 Fax 1 847 955 8208 detectgasOhoneywell com Honeywell Asia Oc ano Pac fico Honeyw
19. ado 2 Um tubo est parcialmente ou completamente bloqueado 3 Uma divis o n o est ventilada de forma adequada TESTAR O SEU ALARME DE MON XIDO DE CARBONO A unidade deve ser testada uma vez por m s premindo o bot o de teste na parte da frente da unidade durante 5 segundos isto testa a c lula electroqu mica a electr nica e o alarme sonoro Se a unidade estiver a funcionar correctamente a luz verde ir ficar iluminada a luz vermelha ir ficar intermitente e o alarme ir soar Em caso de avaria a unidade ir fornecer sinais visuais e sonoros uma vez por minuto Estes sinais podem ser accionados a qualquer momento pressionando o bot o de teste 1309 a 67 Vo7 Vo Modelo H450EN G s Detectado Mon xido de Carbono Princ pio de Detec o C lula electroqu mica Luz vermelha intermitente e alarme sonoro Indica o de Alarme N veis de Alarme 50ppm Entre 60 a 90 mins 100ppm Entre 10 a 40 mins 300ppm Menos de 3 mins Temperatura de Funcionamento 10 C a 40 C Amplitude de Humidade 30 a 90 RH sem condensa o Tempo de aquecimento ap s a primeira liga o Instant neo Vida til em Funcionamento Normal At 7 anos e meio Vida til das pilhas quando em alarme Pelo menos 5 dias Dimens es 110mm x 76mm x 34mm Peso CUIDADO E MANUTEN O DO ALARME O alarme de Mon xido de Carbono vem pr calibrado de f brica e n o necessita de manuten o a n o ser limpar ocasionalmente a
20. alsiasi dubbio in merito al corretto smaltimento del dispositivo e della batteria una volta esauriti contattare un centro di conferimento e riciclaggio dei rifiuti o il centro di assistenza telefonica Honeywell che risponde al numero stampato su questo manuale fN mn Se il dispositivo emette un allarme procedere come segue Aprire tutte le porte e le finestre per aerare il locale e consentire la dispersione del Monossido di Carbonio Se possibile spegnere tutti gli apparecchi a combustione e smettere di usarli Uscire di casa lasciando le porte e le finestre aperte Chiamare la societ del gas o il fornitore del combustibile ai numeri di emergenza ed illustrare il problema Tenere i numeri di telefono di emergenza bene in vista Non rientrare in casa fino a quando l allarme non smette di suonare Se qualcuno dei presenti lamenta sintomi come cefalea nausea etc richiedere l intervento immediato del medico e avvertirlo dell eventualit di avvelenamento da Monossido di Carbonio Non riutilizzare gli apparecchi a combustione se non sono stati controllati e approvati per l uso da un tecnico competente nel rispetto delle norme vigenti Questo prodotto conforme alle direttive europee sulla bassa tensione 2006 95 CE e sulla compatibilit elettromagnetica 2004 108 CE La dichiarazione di conformit completa del fabbricante disponibile al sito www honeywellanalytics com Honeywell Analytics Inc 405 Barclay Blvd Lincol
21. cio Caso seja necess rio o alarme sonoro pode ser silenciado durante 5 minutos primindo o bot o com a marca Teste A luz de alarme vermelha continuar intermitente 5 vezes por segundo Se o Mon xido de Carbono ainda estiver presente passados os 5 minutos do per odo de sil ncio o alarme sonoro ir soar AVISO A funcionalidade de sil ncio n o ir funcionar a n veis acima dos 350ppm de Mon xido de Carbono A n veis abaixo dos 350ppm a funcionalidade de sil ncio ir funcionar apenas uma vez por exemplo o alarme sonoro s pode ser silenciado por um nico per odo de 5 minutos Regressar ao Funcionamento Normal Assim que o g s de Mon xido de Carbono dispersar o sinal de alarme ir parar A luz de estado ir ficar verde intermitente uma vez por minuto Aviso de Falha Se for detectada uma falha o dispositivo sonoro emite dois sons breves por minuto A unidade deve assim ser substitu da Aviso de Falha das Pilhas Fim da Vida til das Pilhas O dispositivo sonoro ir emitir um som breve por minuto AVISO Mediante uma utiliza o normal as pilhas ir o durar pelo menos 7 anos Contudo o tempo de vida das pilhas ser reduzido se ocorrer uma falha com as mesmas ou se a unidade permanecer em alarme durante longos per odos de tempo No caso de ocorrer um falha com as pilhas contacte o seu fornecedor Luz de Alarme Vermelha Luz de Estado Dispositivo Sonoro 1 luz verde intermitente por minuto
22. di un trillo In presenza di monossido di carbonio il LED rosso di allarme lampeggia continuamente e l avvisatore acustico suona Il dispositivo adatto all uso in ambienti chiusi e in presenza di apparecchi di cottura e riscaldamento che bruciano combustibili quali legno carbone di legna carbone coke petrolio benzina gas e cos via COS IL MONOSSIDO DI CARBONIO II Monossido di Carbonio CO un gas velenosissimo generato dalla combustione invisibile e inodore quindi molto difficile da individuare per l uomo primi sintomi allarmanti che segnalano la presenza di CO nell aria di solito sono mal di testa e nausea In condizioni di funzionamento normali se gli apparecchi a combustione sono sottoposti a una corretta manutenzione e l ambiente che li ospita ben ventilato la quantit di Monossido di Carbonio rilasciata nell aria non pericolosa Il Monossido di Carbonio pu diventare pericoloso in presenza di una o pi tra le condizioni elencate di seguito 1 Apparecchio guasto o non sottoposto a regolare manutenzione 2 Condotto totalmente o parzialmente bloccato 3 Ambiente non adeguatamente ventilato VERIFICA FUNZIONALE DELL ALLARME PER MONOSSIDO DI CARBONIO Questo dispositivo deve essere sottoposto una volta al mese a verifica funzionale tenendo premuto il pulsante TEST sulla parte frontale per 5 secondi In questo modo si controlla la funzionalit della cella elettrochimica dei componen
23. e Mon xido de Carbono liberada por dichos aparatos no resulta peligrosa Puede generarse una cantidad peligrosa de Mon xido de Carbono si se da una o varias de estas condiciones 1 Un aparato es defectuoso o no recibe un mantenimiento correcto 2 Hay una salida de humos parcial o totalmente obstruida 3 La estancia no est ventilada adecuadamente PRUEBA DE LA ALARMA DE MON XIDO DE CARBONO La unidad se debe comprobar una vez al mes manteniendo pulsado el bot n de prueba que hay en el frontal durante cinco segundos de esta manera se prueban la celda electroqu mica la electr nica y la alarma sonora Si la unidad funciona correctamente la luz verde permanecer encendida la luz roja parpadear y la alarma sonar En caso de que haya alg n fallo la unidad emite se ales visuales y sonoras una vez por minuto Estas se ales se pueden activar en cualquier momento con tan solo pulsar el bot n de prueba ESPECIFICACIONES Modelo H450EN Gas detectado Mon xido de Carbono Principio de detecci n Celda electroqu mica Indicaci n de alarma Luz roja intermitente y alarma sonora Niveles de alarma 50ppm Entre 60 y 90 minutos 100ppm Entre 10 y 40 minutos 300ppm Menos de 3 minutos Temperatura de funcionamiento De 10 C a 40 C Rango de humedad De 15 a 90 HR sin condensaci n Arranque tras conexi n inicial Instant neo Vida til normal Hasta 7 a os Duraci n de la pila con la alarma act
24. e cabeza v rtigo y n useas tras 1 02 minutos Muerte a los 10 o 15 minutos UBICACI N DE LA ALARMA 1 Unidades situadas en la misma habitaci n que un aparato de combusti n e Sise monta en la pared la unidad debe situarse a una altura superior a la de cualquier puerta o ventana pero a un m nimo de 150mm del techo Si se monta en el techo debe situarse a un m nimo de 300mm de las paredes e La unidad debe estar a una distancia de entre 1 y 3m de la posible fuente de emisi n e Sila habitaci n est dividida por un tabique la unidad se debe instalar en el mismo lado del tabique que la posible fuente de emisi n e En habitaciones con techo inclinado la unidad debe estar situada en el lado m s alto de la habitaci n 2 Unidades situadas en dormitorios y habitaciones alejadas de un aparato de combusti n e las unidades se deben situar relativamente cerca de la zona de respiraci n de los ocupantes D NDE NO INSTALAR LA ALARMA No instale la unidad en las siguientes zonas e Fuera del edificio e Enun armario o debajo del mismo e En un entorno mojado o muy h medo como un ba o e Justo encima de un fregadero o de una cocina e Cerca de una puerta o ventana o en cualquier lugar sujeto a corrientes de aire como un extractor de aire o una rejilla de ventilaci n e Enzonas donde el flujo de aire hacia la unidad quede obstruido por cortinas o mobiliario e All donde la suciedad o el polvo se puedan acu
25. e queima combust vel e As unidades devem ser colocadas relativamente perto da zona de respira o dos ocupantes ONDE N O COLOCAR O ALARME butano etc N o coloque a unidade nas seguintes zonas EM QUE DIVIS O DEVE COLOCAR O ALARME De prefer ncia deve ser colocado um alarme em todas as divis es que contenham um aparelho de queima de combust vel No entanto se houver mais de um aparelho e se o n mero de unidades for limitado devem ser tomados em considera o os seguintes pontos quando se decidir a melhor localiza o e Se houver um aparelho numa divis o onde durmam pessoas deve colocar se uma unidade nesse quarto Deve se colocar uma unidade numa divis o que contenha um aparelho com conduta aberta Se houver um aparelho numa divis o que seja bastante utilizada por pessoas como uma sala de estar deve se colocar uma unidade nessa sala Num apartamento tipo est dio a unidade deve ser colocada t o longe do fog o quanto poss vel mas perto do local onde a pessoa dorme Se o aparelho estiver numa divis o que n o seja normalmente utilizada como uma sala de caldeira a unidade deve ser colocada fora da divis o para que o alarme seja ouvido mais facilmente INSTALA O DO ALARME A unidade pode ser colocada de p ou na parede utilizando os elementos de fixa o fornecidos INSTALA O DE PAREDE Encontre uma posi o para instalar a unidade veja onde colocar o alarme e onde n o
26. ell Analytics Asia Pacific 508 Kolon Science Valley 1 187 10 Guro Dong Guro Gu Nota Seoul 152 050 Se ha puesto el m ximo empe o en garantizar Korea la exactitud de esta publicaci n no obstante declinamos toda responsabilidad por los Tel 82 0 2 2025 0307 posibles errores u omisiones Se pueden Fax 82 0 2 2025 0329 producir cambios tanto en los datos como analytics apOhoneywell com en la legislaci n por lo que se recomienda no e encarecidamente obtener copias actualizadas de Servicios T cnicos la legislaci n las normas y las directrices Esta EMEAI HAexpertOhoneywell com publicaci n no constituye la base de un contrato US ha us serviceOhoneywell com AP ha ap serviceOhoneywell com 156 3495 010 MANO877 Issue 3_11 10_ES O 2010 Honeywell Analytics 12622 www honeywell com Manual de Instru es SF4A50EN Honeywell Carbon Monoxide Detector H 50EN Sea important information on inside of ld Sisus Light Green Ok ola Fault W ESO 2001 Honeywell Alarme de Mon xido de Carbono Manual do Utilizador 156 3495 010 EN50291 2001 INTRODU O Obrigado por adquirir este alarme que foi concebido para detectar a o Luz de Estado presen a de Mon xido de Carbono Bot o de Alarme ade Ok Este manual cont m informa es Teste Vermelha amarelo Avaria sobre a instala o e funcionamento Dispositivo do alarme de Mon xido de Carbono Sonoro Luz de A luz de estado verde fica intermi te
27. est La luz roja de alarma continuar parpadeando 5 veces por segundo 5 parpadeos por segundo Si sigue habiendo Mon xido de Carbono tras el per odo de silencio de 5 minutos se activar la alarma sonora NOTA la funci n de silencio no funcionar con niveles superiores a 350ppm de Mon xido 5 pitidos por segundo de Carbono Con niveles inferiores a 350ppm esta funci n s lo se activar una vez es decir la alarma sonora s lo se puede silenciar durante un per odo de 5 minutos Volver al funcionamiento normal Cuando el Mon xido de Carbono se disperse la se al de alarma parar El indicador luminoso de estado parpadear en verde aproximadamente una vez por minuto Advertencia de fallo Si se detecta un fallo el zumbador emitir 2 sonidos cortos cada minuto Esto indicar que debe sustituirse la unidad Advertencia de fallo de la pila Fin de vida til de la pila El zumbador emitir 1 sonido corto cada minuto NOTA en condiciones de uso normal las pilas durar n 7 a os Sin embargo esta duraci n se reducir si se produce un fallo en la pila o si la alarma de la unidad est activada durante per odos prolongados de tiempo Si se produce una advertencia de fallo de la pila p ngase en contacto con su proveedor QU HACER CUANDO LA ALARMA SUENA Si se activa la alarma de la unidad realice los pasos siguientes e Abra todas las puertas y ventanas para ventilar la zona y dejar que el Mon xid
28. estrutura exterior com um len o de papel sem res duos Certifique se de que os orif cios na parte da frente da unidade n o est o obstru dos com p ou sujidade N O UTILIZE AGENTES DE LIMPEZA LIX VIA OU ESFREGUE FIM DA VIDA TIL DA UNIDADE A unidade ir funcionar at 7 anos e meio em condi es de utiliza o normais A unidade deve ser substitu da quando surge um aviso de bateria fraca 1 som por minuto ou um sinal de aviso de Aproximadamente 110g Esta embalagem contem De prefer ncia recomendado que um alarme de Mon xido de gt Carbono seja instalado nas ou perto de todas as divisdes que tenham um aparelho a queimar combust vel tais como lareiras a g s caldeiras de aquecimento central aquecedores aquecedores No exterior do edif cio e Dentro ou por baixo de um arm rio Numa zona com vapor ou humidade por exemplo uma casa de gua fog es grelhadores etc de banho Este alarme s deve ser instalado por uma pessoa competente e Mesmo acima de um lava lou a ou fog o Certifique se de que o alarme sonoro aud vel a todos e Perto de uma porta ou janela ou em qualquer local que possa Este produto n o deve ser utilizado caso existam quaisquer sinais de avaria Procure ajuda m dica caso suspeite que um membro do seu agregado familiar est a ser v tima de evenenamento por Mon xido de Carbono Caso sejam necess rios mais detalhes que n o constam deste manual contacte a Honeywell a
29. from smoke detector alarms as it signals C O in morse code approximately 5 chirps per second Hush Feature If required the audible alarm can be silenced for 5 minutes by pushing the button 5 flashes per 1 second marked Test The red alarm light will continue to flash 5 times per second If Carbon Monoxide is still present after the 5 minute hush period the audible alarm will sound NOTE The hush facility will not operate at levels above 350ppm Carbon Monoxide At 5 chirps per 1 second levels below 350ppm the hush facility will only operate once ie the audible alarm can only be silenced for one 5 minute period Return to Normal Operation When the Carbon Monoxide gas disperses the alarm signal will stop The status light will flash green approximately once every minute again Fault Warning If a fault is detected the buzzer will sound 2 short chirps every minute The unit must then be replaced Battery Fault Warning End of Battery Life The buzzer will sound 1 short chirp every minute NOTE With normal use the batteries will last for up to 7 years However battery life will be reduced if either a fault occurs with the battery or the unit remains in alarm for long 1 green flash per minute NDA z 2 chirps per N minute and N Yellow yellow flash 1 chirp per minute and yellow flash periods of time Should the Battery Fault Warning occur please contact your supplier WHAT TO DO WHEN THE
30. ganismo 200ppm Leggera cefalea stanchezza vertigini nausea dopo 2030re8 400ppm Cefalea frontale entro 1 o 2 ore pericolo di vita dopo 3 ore 800ppm Vertigini nausea e convulsioni entro 45 minuti Perdita di coscienza entro 2 ore Morte entro 2 0 3 ore 1600ppm Cefalea vertigini e nausea entro 20 minuti Morte entro 1 ora 6400ppm Cefalea vertigini e nausea entro 1 o 2 minuti Morte entro 10 o 15 minuti INSTALLAZIONE DEL DISPOSITIVO 1 Dispositivi installati nello stesso locale di un apparecchio a combustione e n caso di installazione a parete posizionare il dispositivo al di sopra di porte o finestre ma ad almeno 150mm dal soffitto In caso di installazione a soffitto posizionare il dispositivo ad almeno 300mm dalle pareti e installare il dispositivo a una distanza compresa tra 1 e 3m dalla potenziale sorgente e Seillocale presenta una parete divisoria installare il dispositivo sullo stesso lato della potenziale sorgente e n locali con soffitto inclinato installare il dispositivo nella parte piu alta 2 Dispositivi installati in camere da letto e locali lontani dall apparecchio a combustione e Installare i dispositivi in prossimit dell area in cui soggiornano gli occupanti COLLOCAZIONI SCONSIGLIATE DOVE INSTALLARE IL DISPOSITIVO Il dispositivo dovrebbe essere installato in ogni locale dotato di apparecchi a combustione Tuttavia se l ambiente ospita pi apparecchi e il numero di dispositivi
31. h do not appear in this manual contact Honeywell One unit One fixing kit One instruction manual This pack contains EFFECTS OF CARBON MONOXIDE POISONING Carbon Monoxide binds to the haemoglobin in the blood and reduces the amount of oxygen being circulated in the body 200ppm Slight headaches tiredness dizziness nausea after 2 3 hours 400ppm Frontal headache within 1 2 hours life threatening after 3 hours 800ppm Dizziness nausea and convulsions within 45 minutes Unconsciousness with 2 hours Death within 2 3 hours 1600ppm Headache dizziness and nausea within 20 minutes Death within 1 hour 6400ppm Headache dizziness and nausea within 1 2 minutes Death within 10 15 minutes POSITIONING THE ALARM 1 Units located in the same room as a fuel burning appliance e Ifthe unit is located on the wall it should be located at a height greater than the height of any door or window but at least 150mm from the ceiling If the unit is mounted on the ceiling it should be at least 300mm from any wall e The unit should be at a distance of between 1m and 3m from the potential source e Ifthere is a partition in a room the unit should be located on the same side of the partition as the potential source e Inrooms with sloped ceilings the unit should be located at the high side of the room 2 Units located in sleeping rooms and in rooms remote from a fuel burning appliance e Units should be located relativel
32. il Monossido di Carbonio ancora presente allarme acustico riprende NOTA Se il Monossido di Carbonio supera i 350ppm la funzione di silenziamento disabilitata A livelli inferiori a 350ppm la funzione di silenziamento si pu comunque 5 trilli al secondo attivare una sola volta ovvero l allarme acustico si pu disattivare per un solo intervallo di 5 minuti Ripristino del funzionamento normale Quando il Monossido di Carbonio si disperde il segnale di allarme cessa II LED di stato verde lampeggia ogni minuto Segnalazione di guasto Se il dispositivo rileva un guasto l avvisatore acustico emette due brevi trilli ogni minuto Sostituire il dispositivo Segnalazione di guasto esaurimento della batteria L awisatore acustico emette 1 breve trillo ogni minuto NOTA In condizioni di uso normali le batterie durano fino a 7 anni La durata delle batterie pu risultare ridotta in caso di guasto oppure se il dispositivo rimane in allarme per periodi prolungati Se il dispositivo emette il segnale di guasto batteria contattare il rivenditore 1 lampo verde al minuto 2 trilli al minuto e Giallo lampo giallo liz 1 trillo al minuto e N lampo giallo Giallo DICHIARAZIONE DI CONFORMITA tassello di tipo Rawplug Dopo l attivazione e il test vedere Uso dell allarme possibile agganciare il dispositivo al chiodo usando uno dei fori sagomati indicati dalle linee sul retro USO DEL DISPOSITI
33. il funzionamento e n ambienti dove la temperatura potrebbe scendere sotto i 10 C o superare i 40 C e Dove pu subire urti danni o in punti dai quali pu staccarsi inavvertitamente e Non verniciare il dispositivo n lasciare che i fori di ingresso per il monossido di carbonio vengano ostruiti da sporcizia unto O altre sostanze FUNZIONAMENTO DELL ALLARME Funzionamento normale In assenza di Monossido di Carbonio il LED verde di alimentazione lampeggia una volta al minuto Durante il funzionamento normale il dispositivo esegue un test di autodiagnostica ogni sessanta minuti Condizione di allarme Quando il dispositivo rileva la presenza di Monossido di Carbonio emette un segnale di allarme continuo ll LED rosso lampeggia e l avvisatore acustico emette un suono cinque volte al secondo Dopo 30 minuti di allarme il segnale viene emesso una volta al minuto Segnale di allarme LED rosso di allarme Avvisatore acustico 1 lampo verde al minuto 5 trilli al secondo 5 trilli al secondo ogni minuto L allarme del Monossido di Carbonio si distingue da quelli dei rivelatori di fumo perch segnala C O in codice morse 5 impulsi al secondo Funzione silenziamento Se occorre possibile spegnere l allarme acustico per 5 minuti premendo il pulsante Test II LED rosso continua a lampeggiare per 5 volte al secondo 5 lampi da un secondo Se trascorsi i 5 minuti di silenziamento
34. imitado deber n tenerse en cuenta los siguientes aspectos para decidir la mejor ubicaci n e Si hay un aparato en una habitaci n en la que duermen personas se debe instalar una unidad Se debe instalar un unidad en las habitaciones que contengan un aparato sin salida de humos o conectado a una salida de humos abierta Si hay un aparato en una estancia de uso muy frecuente como un sal n se debe instalar una unidad En un estudio la unidad se debe situar lo m s lejos posible del aparato de cocina pero cerca de la zona de dormitorio Si el aparato est en una estancia que normalmente no se utiliza como una sala de calderas la unidad se debe situar justo fuera de la estancia para que resulte m s f cil o r la alarma INSTALACI N DE LA ALARMA La unidad se puede montar por separado o en pared mediante los anclajes proporcionados INSTALACI N EN LA PARED Localice la posici n en la que instalar la unidad consulte D nde instalar la alarma y D nde no instalar la alarma Placa de montaje Opci n 1 Almohadilla especial de montaje con pasador de fijaci n suministrada Inserte el pasador de fijaci n en la almohadilla de montaje Con un Pared o martillo golpee con cuidado el pasador de fijaci n en la pared procurando que Rawplug la almohadilla de montaje no quede _3mm demasiado encastrada en la pared I Opci n 2 Tornillo y taco NO l sumin
35. istrados Sato Tomo Si la pared es demasiado dura para usar el pasador de fijaci n use un tornillo de cabeza redonda del n mero 4 y un Rawplug Una vez activada y probada consulte Uso de la alarma la unidad puede colgarse del pasador de fijaci n mediante una de las ranuras de fijaci n indicadas por l neas en la parte posterior de la misma USO DE LA ALARMA Para activar la unidad extraiga la tira de activaci n que se encuentra en su lateral Las luces verde y roja parpadear n brevemente y el zumbador sonar durante un instante Mantenga pulsado el bot n de prueba Test durante cinco segundos y compruebe que la luz roja parpadea y el zumbador suena Si es as significa que la unidad funciona y est lista para su uso DECLINACI N DE RESPONSABILIDAD Esta alarma detectora de Mon xido de Carbono tiene como finalidad avisarle de una acumulaci n potencialmente peligrosa de Mon xido de Carbono No tiene como finalidad solucionar problemas relacionados con el Mon xido de Carbono ni detectar fuentes concretas de este gas Honeywell no ser responsable del pago de ninguna investigaci n o visita del servicio t cnico relacionada con el Mon xido de Carbono realizada o acordada como respuesta a una alarma GARANT A Garantizamos la nueva alarma detectora de Mon xido de Carbono por un per odo de seis a os a partir de la fecha de compra o hasta la fecha de caducidad indicad
36. ivada Como m nimo 5 d as Dimensiones 110mm x 76mm x 34mm Peso Approximately 110g CUIDADO Y MANTENIMIENTO DE LA ALARMA La alarma de Mon xido de Carbono se suministra precalibrada de f brica y no requiere ning n otro mantenimiento que el de la limpieza ocasional de la carcasa exterior con un pa o limpio Procure que los orificios situados en la parte frontal de la unidad no queden obstruidos por el polvo o la suciedad NO UTILICE PRODUCTOS DE LIMPIEZA LEJ A NI ABRILLANTADOR FIN DE VIDA TIL DE LA UNIDAD Con un uso normal la unidad funcionar durante 7 a os La unidad se debe sustituir cuando emite una advertencia de bater a baja un pitido por minuto o una se al de advertencia de fallo dos pitidos por minuto con el indicador de estado parpadeando en amarillo Se recomienda sustituir la unidad una vez pasada la fecha indicada en su frontal DISPOSAL Cuando se agote la vida til de la unidad des chela de acuerdo con la normativa local al respecto DECLARACI N DE DIRECTIVA DE BATERIAS Por cuestiones de seguridad la alarma H450EN est sellada y la bater a no se puede cambiar Si al finalizar la vida til de la unidad tuviera cualquier duda sobre c mo deshacerse de ella o de la bater a p ngase en contacto con el punto de reciclaje m s cercano o llame al tel fono de asistencia Honeywell que se facilita en este manual A mn LEA DETENIDAMENTE EL CONTENIDO DE ESTE MANUAL DE INSTRUCCIONES
37. mular y obstruir el sensor lo cual afectar a a su funcionamiento e Enuna zona donde la temperatura pueda ser inferior a 10 C o superior a 40 C e All donde pueda ser golpeado o da ado con facilidad o donde se pueda quitar inadvertidamente e No pinte la unidad y evite que se obstruyan las entradas de gas CO con suciedad grasa o cualquier otra sustancia FUNCIONAMIENTO DE LA ALARMA Funcionamiento normal Cuando no hay presencia de Mon xido de Carbono la luz verde de alimentaci n parpadear aproximadamente una vez cada minuto Durante el funcionamiento normal la unidad realiza una prueba de comprobaci n autom tica cada minuto Condici n de alarma Cuando la unidad detecte Mon xido de Carbono emitir la se al de alarma de forma continua La luz roja parpadear y el zumbador sonar aproximadamente 5 veces por segundo Cuando la unidad haya tenido activada la alarma durante 30 minutos la se al de alarma completa se producir cada minuto Se al de alarma indica Luz Zumbador dor lumi roja de noso de alarma estado 1 parpadeo en verde por minuto 5 pitidos por segundo 5 pitidos por segundo por minuto La alarma de Mon xido de Carbono se distingue de las alarmas detectoras de humo en que indica la presencia de CO en c digo morse 5 por segundo Funci n de silencio Si es necesario la se al sonora de alarma puede silenciarse durante 5 minutos pulsando el bot n T
38. n consente di inserire il chiodo usare madamente 1 minuto para indicar ossido di Carbonio Ingresso gas incompleta di combustibili come legno carbone di legna una vite a testa tonda numero 4 e un que a unidade est a funcionar correctamente Esta situac o ser alterada para uma luz intermitente amarela com som se ocorrer uma avaria A luz de alarme vermelha ir ficar continuamente intermitente e o dispositivo sonoro ir soar na presenca de Mon xido de Carbono A unidade adequada para ser utilizada em zonas onde aparelhos de cozinha e de aquecimento quiemam combust veis como madeira carv o vegetal e mineral coque petr leo gasolina g s etc O QUE O MON XIDO DE CARBONO O Mon xido de Carbono CO um g s altamente venenoso que libertado quando os combust veis s o queimados invis vel inodoro e consequentemente muito dif cil de detectar pelos sentidos humanos Os primeiros sintomas de alerta de que o CO est presente no ar s o geralmente dores de cabe a e n useas Sob condi es de funcionamento normais numa divis o onde os aparelhos que queimam combust veis s o bem cuidados e correctamente ventilados a quantidade de Mon xido de Carbono libertado para a divis o pelos aparelhos n o perigosa Uma quantidade de Mon xido de Carbono perigosa pode ocorrer se se verificar uma ou mais das situa es que se seguem 1 Um aparelho est defeituoso ou n o est devidamente cuid
39. n xido de Carbono Manual del usuario 156 3495 010 EN50291 2001 INTRODUCCI N Gracias por adquirir esta alarma LE Indicador luminoso concebida para detectar la pres Bot n de roja de de estado encia de Mon xido de Carbono E g alarma Verde Correcto Este manual contiene informaci n P YeDa Amarillo Fallo acerca de la instalaci n y el funcionamiento de la alarma de Mon xido de Carbono El indicador luminoso de estado parpadea en verde a intervalos de un minuto aproximadamente para indicar que la unidad est funcionando correctamente Si se produce un fallo la luz parpadea en amarillo y al mismo tiempo se emite un pitido Si se detecta mon xido de carbono la luz roja de alarma parpadea de forma continua y el zumbador suena La unidad es adecuada para zonas en las que se encuentran aparatos de cocina y de calefacci n que queman combustible como madera carb n vegetal carb n coque gas leo gasolina gas etc QU ES EL MON XIDO DE CARBONO El Mon xido de Carbono CO es un gas muy t xico que se desprende cuando se queman combustibles Es invisible inodoro y por lo tanto es muy dif cil de detectar con los sentidos humanos Los primeros s ntomas de advertencia que indican la presencia de CO en el aire suelen ser dolores de cabeza y n useas En condiciones normales en una habitaci n en la que los aparatos de combusti n tienen un buen mantenimiento y est n correcta mente ventilados la cantidad d
40. nshire IL 60069 USA Tel 1 847 955 8200 Toll free 1 800 538 0363 Fax 1 847 955 8208 detectgasOhoneywell com Estremo Oriente Honeyw el Honeywell Analytics Asia Pacific 508 Kolon Science Valley 1 187 10 Guro Dong Guro Gu N B Seoul 152 050 Abbiamo fatto del nostro meglio per garantire Korsa l assoluta precisione della documentazione fornita Tuttavia l azienda non si assume Tel 82 0 2 2025 0307 alcuna responsabilit per eventuali errori od Fax 82 0 2 2025 0329 omissioni Poich dati e leggi sono soggetti a analytics ap honeywell com variazioni raccomandiamo a tutti i nostri clienti di richiedere copie aggiornate di regolamenti norme e linee guida Questa pubblicazione non riveste carattere contrattuale Assistenza Tecnica EMEAI HAexpert honeywell com US ha us service honeywell com AP ha ap service honeywell com 156 3495 010 MANO8S77 Issue3 110 IT O 2010 Honeywell Analytics 12622 www honeywell com
41. nte em intervalos de aproxi EFEITOS DA INTOXICAC O COM MON XIDO DE CARBONO LEIA COM ATEN O E COMPREENDA O CONTE DO DESTE MANUAL DE INSTRU ES ANTES DE UTILIZAR O ALARME GUARDE ESTE MANUAL NUM LOCAL SEGURO PARA FUTURA CONSULTA 200ppm PRESTE PARTICULAR ATEN O AOS AVISOS DE SEGURAN A TODOS OS UTILIZADORES DO ALARME DEVEM LER ESTE MANUAL 400ppm AVISO 800ppm ESTE ALARME PARA MON XIDO DE CARBONO PODE N O PROTEGER PESSOAS QUE ESTEJAM SUJEITAS A UM RISCO ESPECIAL DE EXPOSI O AO MON XIDO DE 1600ppm CARBONO POR MOTIVOS DE IDADE GRAVIDEZ E ESTADO M DICO SE TIVER D VIDAS CONSULTE O SEU M DICO 6400ppm Este Alarme de Mon xido de Carbono N O Um substituto para um alarme de fumo ou detector de g s combust vel Para funcionar como substituto para um funcionamento adequado para os aparelhos que queimam combust vel ou varrer chamin s Para ser utilizado em base intermitente ou como detector port til em caso de derramamento de produtos de combust o causado por aplica es de queima de combust vel ou chamin s ATEN O Este alarme de Mon xido de Carbono foi concebido apenas para ser utilizado em interiores N o o exponha chuva ou humidade N o d pancadas ou deixe cair a unidade N o abra ou altere a unidade uma vez que isso pode causar uma avaria e O alarme n o ir proteger contra o risco de intoxica o de Mon xido de Carbono quanto a bateria se esgotar IMPORTANTE O M
42. o de Carbono se disperse e Cuando sea posible apague todos los aparatos que utilicen combustible y deje de utilizarlos e Evac e el lugar y deje todas las puertas y ventanas abiertas e Llame al n mero de emergencias del proveedor de gas o del combustible correspondiente y explique el problema Coloque el n mero de tel fono en un lugar bien visible e No vuelva a entrar hasta que se haya detenido la alarma e Solicite inmediatamente asistencia m dica para cualquier persona que sufra intoxicaci n por los efectos del Mon xido de Carbono como dolores de cabeza n useas etc e informe de que cree que se trata de intoxicaci n por Mon xido de Carbono e No vuelva a utilizar los aparatos de combusti n hasta que hayan sido revisados y validados por un t cnico cualificado seg n la normativa vigente 1 parpadeo en verde por minuto 2 pitidos por minuto y parpadeo en amarillo 1 pitido por minuto y parpadeo en Amarillo amarillo DECLARACI N DE CONFORMIDAD Este producto cumple las directivas europeas de baja tensi n 2006 95 CE y de compatibilidad electromagn tica 2004 108 CE La copia completa de la declaraci n de conformidad del fabricante se encuentra en la siguiente direcci n www honeywellanalytics com EN QU ESTANCIA SE DEBE INSTALAR LA ALARMA Lo ideal ser a instalar una alarma en cada habitaci n que contenga un aparato de combusti n No obstante si hay varios aparatos y el n mero de unidades es l
43. on xido de Carbono produzido pela combust o incompleta de combust veis como madeira carv o vegetal e mineral leo de aquecimento parafina gasolina g s natural propano O Mon xido de Carbono combina com a hemoglobina no sangue e reduz a quantidade de oxig nio que circula no corpo Dores de cabe a ligeiras cansa o tonturas n usea ap s 2 3 horas Dores de cabe a frontais em 1 2 horas existindo risco de vida decorridas 3 horas Tonturas n usea e convuls es em menos de 45 minutos Perda de consci ncia em 2 horas Morte em 2 3 horas Dores de cabe a tonturas e n usea em menos de 20 minutos Morte em menos de 1 hora Dores de cabe a tonturas e n usea em 1 2 minutos Morte entre os 10 15 minutos INSTALA O DO ALARME 1 Unidades colocadas na mesma divis o onde existem aparelhos de queima de combust vel e Sea unidade estiver colocada na parede deve estar localizada a uma altura superior altura de qualquer porta ou janela mas pelo menos a 150mm do tecto Se a unidade estiver montada no tecto deve estar pelo menos a 300mm de qualquer parede e A unidade deve estar a uma dist ncia entre 1m e 3m da fonte potencial Se houver uma divis ria na sala a unidade deve ser colocada no mesmo lado da fonte potencial Nas divis es com tectos inclinados a unidade deve ser colocada no lado mais alto da sala 2 Unidades colocadas em quartos de dormir e em divis es distantesde um aparelho d
44. oxide released into the room by the appliances is not dangerous A dangerous quantity of Carbon Monoxide can occur if one or more of the following conditions exists 1 An appliance is faulty or is badly maintained 2 A flue is partially or totally blocked 3 A room is not adequately ventilated TESTING YOUR CARBON MONOXIDE ALARM The unit should be tested once a month by pressing and holding the test button on the front of the unit for 5 seconds this tests the electrochemical cell electronics and audible alarm If the unit is functioning correctly the green light will stay illuminated the red light will flash and the alarm will sound In case of a fault the unit is giving visual and audible signals once per minute These signals can be triggered any time by pressing the test button SPECIFICATION Model H450EN Gas Detected Carbon Monoxide Detection Principle Electro chemical cell Alarm Indication Flashing red light and audible alarm Alarm Levels 50ppm Between 60 to 90 mins 100ppm Between 10 to 40 mins 300ppm Less than 3 mins Operating Temperature 10 C to 40 C Humidity Range 30 to 90 RH non condensing Warm up time after initial switch on Instantaneous Normal Operating Life Up to 7 years Battery life when in alarm At least 5 days Dimensions 110mm x 76mm x 34mm Weight CARE AND MAINTENANCE OF ALARM The Carbon Monoxide alarm is pre calibrated at the factory and requires no maintenance o
45. sford Road US ha us serviceVhoneywell com Nutfield Industrial Estate AP ha ap serviceVhoneywell com Poole Dorset BH17 ORZ Tel 44 0 1202 645577 Fax 44 0 1202 665331 consumerOhoneywell com www honeywell com Europe Middle East Africa India Life Safety Distribution AG Weiherallee 11a CH 8610 Uster Switzerland Tel 41 0 44 943 4300 Fax 41 0 44 943 4398 gasdetectionVhoneywell com Americas Honeywell Analytics Inc 405 Barclay Blvd Lincolnshire IL 60069 USA Tel 1 847 955 8200 Toll free 1 800 538 0363 Fax 1 847 955 8208 detectgasOhoneywell com Honeywell Please Note While every effort has been made to ensure accuracy in this publication no responsibility can be accepted for errors or omissions Data may change as well as legislation and you are strongly advised to obtain copies of the most recently issued regulations standards and guidelines This publication is not intended to form the basis of a contract Asia Pacific Honeywell Analytics Asia Pacific 508 Kolon Science Valley 1 187 10 Guro Dong Guro Gu Seoul 152 050 Korea Tel 82 0 2 2025 0307 Fax 82 0 2 2025 0329 analytics apOhoneywell com 156 3495 010 MANO8S77 Issue 3 11 10 EMEAI O 2010 Honeywell Analytics 12622 Manual de instrucciones H450EN Honeywell Carbon Monoxide Detector HAS0EN See importam Information on inside of ld Sica Light Greer Ok Yelow Fall W EMBORA I 2001 Honeywell Alarma de Mo
46. ssoa competente de acordo com as regulamenta es nacionais Honeywell Analytics Inc 405 Barclay Blvd Lincolnshire IL 60069 USA Tel 1 847 955 8200 Toll free 1 800 538 0363 Fax 1 847 955 8208 detectgasOhoneywell com sia Pac fico Honeywell Analytics Asia Pacific 508 Kolon Science Valley 1 187 10 Guro Dong Guro Gu Seoul 152 050 Korea Tel 82 0 2 2025 0307 Fax 82 0 2 2025 0329 analytics apOhoneywell com Honeywell Atenc o Apesar de terem sido feitos todos os esforcos para garantir exactid o nesta publica o n o aceite qualquer responsabilidade por erros ou omiss es Os dados podem ser alterados bem como a legisla o e aconselhamo lo veementemente a obter c pias das regula es normas e directivas emitidas mais recentemente Esta publica o n o tem a inten o de formar qualquer v nculo contratual Servi os T cnicos EMEAI HAexpertOhoneywell com US ha us serviceOhoneywell com AP ha ap serviceQhoneywell com 156 3495 010 MANO877_lssue 3_11 10_PT O 2010 Honeywell Analytics 12622 www honeywell com minuto e LED di stato giallo intermittente Si raccomanda di sostituire il dispositivo dopo la data indicata sulla parte frontale SMALTIMENTO dispositivi esauriti vanno smaltiti conformemente alle leggi vigenti DISPOSIZIONI SULLA BATTERIA Per ragioni di sicurezza il dispositivo H450EN non pu essere aperto e la batteria non sostituibile Per qu
47. ther than to clean the outside case occasionally with a clean tissue Ensure that the holes on the front of the unit are not blocked with dust or dirt DO NOT USE CLEANING AGENTS BLEACH OR POLISH END OF UNIT LIFE The unit will operate for up to 7 years under normal use The unit must be replaced when a low battery warning 1 chirp per minute or a fault warning signal 2 chirps per minute and the status light flashing yellow is given It is recommended to replace the unit after the date marked on the front of the unit Approximately 110g DISPOSAL When the unit has come to the end of its life dispose of it in accordance with local regulations BATTERY DIRECTIVE STATEMENT For safety reasons the H450EN is a sealed unit and the battery is not replaceable At the end of the unit s life if you have any concerns over the safe disposal of the unit battery please contact your local recycling centre or the Honeywell helpline printed in this manual DAA AN Ce CAREFULLY READ AND UNDERSTAND THE CONTENTS OF THIS INSTRUCTION MANUAL BEFORE USING THE ALARM RETAIN THE MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE PAY PARTICULAR ATTENTION TO THE SAFETY WARNINGS PASS THE MANUAL ONTO ANY SUBSEQUENT USERS OF THE ALARM WARNING THIS CARBON MONOXIDE ALARM MAY NOT PROTECT PEOPLE WHO ARE AT SPECIAL RISK FROM CARBON MONOXIDE EXPOSURE BY REASON OF AGE PREGNANCY OR MEDICAL CONDITION IF IN DOUBT CONSULT YOUR MEDICAL PRACTITIONER
48. ti si evidenzino in condizioni d impiego e servizio normali Il produttore non si impegna a riparare n sostituire dispositivi i cui difetti siano in qualche modo imputabili a danneggiamento negligenza uso improprio o dispositivi che siano stati manomessi o smontati Se lo strumento dovesse presentare qualche problema contattate il vostro fornitore locale Allegare una lettera di accompagnamento che descriva dettagliatamente il problema riscontrato sul dispositivo di allarme La garanzia non interferisce con i diritti di legge del consumatore Vi preghiamo di registrare il vostro strumento a www sfdetection com Per maggiori informazioni visitate il sito www honeywellanalytics com Per contattare Europa Medio Oriente Africa e India Life Safety Distribution AG Weiherallee 11a CH 8610 Uster Switzerland Tel 41 0 44 943 4300 Fax 41 0 44 943 4398 gasdetectionOhoneywell com COSA FARE SE SUONA L ALLARME DECLARA O DE CONFORMIDADE O QUE FAZER QUANDO O ALARME SOAR avaria 2 sons por minuto e a luz de estado intermitente amarela Am rica do Norte Sul Nord e Sud America Recomenda se a substitui o da unidade ap s a data indicada na parte dianteira da unidade ELIMINA O Quando a unidade chegar ao fim da sua vida til elemine a de acordo com as regulamenta es locais DECLARA O DA DIRECTIVA RELATIVA A PILHAS E BATERIAS Por raz es de seguran a o H450EN uma unidade selada e a
49. ti elettronici e dell allarme acustico Se il dispositivo funziona correttamente il LED verde rimane acceso il LED rosso lampeggia e l allarme acustico suona In caso di guasto il dispositivo emette un segnale visivo e acustico ogni minuto Questi segnali possono essere attivati in qualsiasi momento premendo il pulsante Test DATI TECNICI Modello Gas Rilevato H450EN Monossido di Carbonio Principio di rilevamento Cella elettrochimica LED rosso intermittente e allarme acustico Indicatore di allarme Livelli di allarme 50ppm per un periodo tra 60 e 90 min 100ppm per un periodo tra 10 e 40 min 300ppm per meno di 3 min da 10 C a 40 C da 30 a 90 relativa senza condensa Temperatura di esercizio Umidit di esercizio Tempo di riscaldamento Istantaneo Durata standard Fino a 7 anni Durata della batteria in condizione di allarme Almeno 5 giorni Dimensioni 110mm x 76mm x 34mm Peso Circa 110g CURA E MANUTENZIONE DEL DISPOSITIVO DI ALLARME L allarme per Monossido di Carbonio tarato in fabbrica e non richiede altra manutenzione oltre alla pulizia occasionale della parte esterna con un panno pulito Controllare che i fori sulla parte frontale non siano ostruiti da polvere o sporco NON USARE DETERGENTI CANDEGGINA O LUCIDI DURATA DEL DISPOSITIVO In condizioni normali il dispositivo pu funzionare fino a 7 anni Sostituire il dispositivo quando segnala l esaurimento della batteria un trillo al minuto
50. y close to the breathing area of the occupants Do not place the unit in the following areas e Outside the building e Inor below a cupboard e Ina damp or highly humid area e g a bathroom e Directly above a sink or cooker e Nextto a door or window or anywhere that would be affected draughts eg extractor fan or air vent e Where the air flow to the unit would be obstructed by curtains or furniture e Where dirt or dust could collect and block the sensor and stop it working e nan area where the temperature could drop below 10 C or rise to above 40 C e Where it could be easily knocked damaged or where it could be inadvertently removed e Do not paint the unit or allow the CO gas inlets to become blocked by dirt grease or other substances OPERATION OF THE ALARM Normal Operation When no Carbon Monoxide is present the status light will flash green approximately once every minute 1 green flash per minute During normal operation the unit carries out a self check test every 5 minutes Alarm Condition When the unit detects Carbon Monoxide it will give the alarm signal continuously The red alarm light will flash and the buzzer will sound approximately 5 chirps per second When the unit has been in alarm for 30 minutes the full alarm signal will be given once every minute Alarm Signal 5 chirps per 1 second 5 chirps per 1 second per minute The Carbon Monoxide alarm can be distinguished