Home
mc multizone - quick guide
Contents
1. 040000040 rel 1 1 16 12 2014 wu mc multizone quick guide CAREL Caratteristiche Modelli Characteristics Models gt QUESTE ISTRUZIONI van linea acqua MC060 D 0 MC060 1 0 MC230 D 0 MC230 1 0 of the water MC060 D 0 MC060 1 0 MC230 D 0 MC230 1 0 BA UA portata max l h Ib h 60 l h 130 Ib h 60 l h 130 Ib h 230 l h 500 Ib h 230 l h 500 Ib h line max flow rate 60 l h 130 1b h 60 l h 1301b h 230 l h 500lb h 230 I h 500 Ib h CA G d 380G d 130 Ib h 1450 G d 1450 G d l h Ib h G d 380G d 130 Ib h 1450 G d 1450 G d pressione ingresso 0 3 0 7 Mpa 3 7 Bar 40 100 PSI inlet pressure 0 3 to 0 7
2. Mpa 3 to 7 Bar 40 to 100 PSI Mpa Bar PSl Mpa Bar PSI temperatura 1 50 C 34 122 F temperature 1 to 50 C 34 to 122 F ingresso G1 2 F NPT1 4 F G1 2 F NPT1 4 F inlet G1 2 F NPT1 4 F G1 2 F NPT1 4 F uscita G1 2 F NPT1 2 F G1 2 F NPT1 2 F outlet G1 2 F NPT1 2 F G1 2 F NPT1 2 F scarico TCF 8 10 NPT1 4 F TCF 8 10 NPT1 4 F drain TCF 8 10 NPT1 4 F TCF 8 10 NPT1 4 F Caratteristiche Modelli Characteristics Models linea aria MC060 D 0 MCo60 1 0 MC230 D 0 MC230 1 0 of theair line MC060 D 0 MC060 1 0 MC230 D 0 MC230 1 0 pressione ingresso 0 5 0 7 Mpa 5 7 Bar 80 100 PSI inlet pressure 0 5 to 0 7 Mpa 5 to 7 Bar 80 to 100 PSI Mpa Bar PSl Mpa Bar PSI temperatura 1 50 C 34 122 F temperature 1 to 50 C 34to 122 F ingresso G1 2 F NPT1 2 F G1 2 F NPT1 2 F inlet G1 2 F NPT1 2 F G1 2 F NPT1 2 F uscita G1 2 F NPT1 2 F G1 2 F NPT1 2 F outlet G1 2 F NPT1 2 F G1 2 F NPT1 2 F Caratteristiche codice descrizione attacchi riferimento in fig 2 Water and air code description fittings refernce in fig 2 accessori linee _MCFILOILO1 filtro olio 3 8 x aria G3 8 f in out 2 line accessories MCFILOILO 3 8 oil filter for air G3 8 f in out 2 acqua e aria MCFILAIRO1 filtro aria 1 2 G1 2 f in out 3 MCFILAIRO 1 2 air filter G1 2 fin out 3 MCFILWATO5 contenitore filtro acqua 5 G1 2 f in out 4 MCFILWATO5 5 water filter container G1 2 fin out 4 MCKSUVO000 kit sanificatore a raggi uv G1 4 fin out 5 MCKSUV
3. 0000 __ UV santising kit G1 4 fin out 5 MCKPT 000 trasduttore di pressione G1 4 m 10a MCKPT 000 pressure traqnsducer G1 4 m 10a MCKMA04000 _ manometro aria uscita 0 4 bar G1 4 m 10b MCKMA04000 _ airoutlet pressure gauge 0 to 4 bars G1 4 m 10b MCKDVWL00 elettrovalvola NA fine linea G1 4 f in out 13 MCKDVWL00 NO solenoid valve at end of line G1 4 fin out 13 Fig 1 MCKMW02501 manometro acqua uscita 0 2 5 bar G1 4 m 14 MCKMW02501 wateroutletpressure gauge 0 to 2 5 bars _ G1 4 m 14 Modelli MC D 230 V 50 Hz Models MC D 230 V 50 Hz Caratteristiche MC CD 00 MC CD 01 MC HD 00 MC HD 01 Electrical MC CD 00 MC CD 01 MC HD 00 MC HD 01 elettriche Vac fasi Hz 230 V 1 50 60 Hz 230 V 1 50 Hz 230V 1 50 60 Hz 230V 1 50 Hz specifications Vac fasi Hz 230 V 1 50 60 Hz 230 V 1 50 Hz 230 V 1 50 60 Hz 230 V 1 50 Hz Potenza 37W 44W 41W 48 W Power 37W 44 W 41W 48 W Corrente 0 26 A 0 29 A 0 30 A 0 33 A Current 0 26 A 0 29 A 0 30 A 0 33 A Prodotto in conformit con EN55014 EN61000 EN60335 Product in compliance with EN55014 EN61000 EN60335 Modelli MC 1 110 V 60 Hz Models MC 1 110 V 60 Hz Caratteristiche MC C1 00 MC C1 01 MC H1 00 MC H1 01 Electrical MC C1 00 MC C1 01 MC H1 00 MC H1 01 elettriche Vac fasi Hz 110V 1 60 Hz specifications Vac fasi Hz 110 V 1 60 Hz Potenza 37W 44 N 41W 48 W Power 37W 44W 41W 48 W Corrente 0 54 A 0 60 A 0 64 A 0 70 A Current 0 54 A 0 60 A 0 6
4. 4 A 0 70 A Prodotto omologato UL998 e CSA C22 2 No104 Product approved to UL998 amp CSA C22 2 No104 Alimentazione elettrica Collegamento ON OFF remoto ID e COM Power supply Remote ON OFF ID amp COM Cabinet MC Cavo alimentazione Cabinet MC ON OFF remoto MC Cabinet Power cable MC Cabinet Remote ON OFF L L F fase IDI NC NO L L F Phase IDI NC NO N N W neutro COM 1 02 0 3 C N N W neutral COM 1020 3 C GR GR PE terra GR schermo GR GR PE earth GR Sh Collegamento regolatore modulante esterno Collegamento sonda umidit Modulating control with external controller Ambient humidity probe connection Cabinet MC regolatore esterno Cabinet MC sonda umidit ambiente MC Cabinet external controller MC Cabinet ambient humidity probe J24 GND REF schermo V term G J24 GND REF schermo J24 V term G J2 BI OUT 5 GND M J2 B1 OUT GND M Collegamento regolatore modulante con sonda Collegsinanii d gl d TETE Modulating control with controller and limit probe Ambient probe and limit probe connection umidit limite oilegamento sonda umiadita e sonda umiaita mite Me cabin limit humidity sui necnin limit humidity ambient humidity Cabinet MC sonda umidit regolatore biro sonda umid sonda umid probe controller probe probe limite esterno limite ambiente J24 V term G J24 V term G G V term G V term G G ND M ii OND m M l Eaa o J24 NT i J24 GND NI M P BI OUT P B1 out H Attenzione prima di procedere assicurarsi che l um
5. avaggio automatico periodico linea acqua per aumentare l igienicit dell impianto parametro range default _ U M parametro range default _ U M fbilitata SI NO SI lavaggio man autom man 0 999 30 min NO SI NO 60 999 160 S SS 6 h ale 10 min NO SI NO 1 1000 5 S parametro range default U M selezione Visualizzazione maschera principale segnale Ore rH C F rH i italiano inglese francese tedesco spagnolo pa SI NO SI Alarm input from external devices MC Cabinet Relay ID3 ON OFF COMI COM Alarm relay from water treatment IDA ONONE Compressor alarm rela COMI COM p y ID6 ON OFF COM2 COM Air flow switch alarm raly GR shield External contact for activating the ash function Proportional 0 to10 Vdc output MC Cabinet kelay ro LL Weston MC Cabinet Outputs external signal ID7 ON OFF VGO RIF COMI COM Y1 0 10 Vdc Output specifications maximun load T kO T0 mA Configuration Installer menu configuration parameters From the main screen press PROG to access the main menu DOWN to move to the installer menu ENTER to move to the password UP DOWN to enter the password 77 ENTER to access the selected menu UP DOWN to move between the submenus ENTER to select the paramenter and move between the parameters e UP DOWN to modify the parameter ENTER to confirm the s
6. distanza massima tra due cabinet 200m 219 yd In modalit multizone disattivando la funzione stop slave off line in caso di interruzione pLan le unit slave fun zionano autonomamente secondo i segnali provenienti dalle sonde o e regolatori In questa modalit i valori non verranno visualizzati dal display del master Use two wire cables plus earth AWG 20 22 maximum distance between two cabinets 200 m 219 yd In multizone mode by disabling the stop slave off line function if the pLAN is interrupted the slaves operate independently according to the signals from the probes or and controllers In this mode the values will not be shown on the master display AVVERTENZE IMPORTANTI PRIMA DI INSTALLARE O MANEGGIARE IL DISPOSITIVO LEGGERE ATTENTAMENTE E SEGUIRE LE ISTRUZIONI E LE NORME PER LA SICUREZZA DESCRITTE NEL PRESENTE MANUALE ED ILLUSTRATE SULLE TARGHETTE APPLICATE SUL DISPOSITIVO L installazione uso e manutenzione siano effettuate in conformit con le istruzioni fornite nel presente manuale e con le normative legali vigenti Ogni altro uso del dispositivo e modifica effettuata sull unit senza l autorizzazione di CAREL S p A sono considerati impropri Le condizioni ambientali e l alimentazione devono essere conformi alle indicazioni specificate Togliere l alimentazione prima di intervenire direttamente sulle le parti interne del prodotto La responsabilit degli eventuali danni a cose o persone dovuti ad un uso improprio d
7. el dispositivo ricadr esclusivamente sull utente Si prega di tener presente che l unit contiene dispositivi alimentati elettricamente e componenti ad alta pressione Tutte le operazioni legate al funzionamento e o alla manutenzione dell unit devono essere effettuate da personale esperto e qualificato a conoscenza delle necessarie precauzioni Smaltimento delle parti dell umidificatore l umidificatore composto da parti in metallo e da parti in plastica In riferimento alla Direttiva 2002 96 CE del Parlamento Europeo e del Consiglio del 27 gennaio 2003 e alle relative normative nazionali di attuazione Vi informiamo che 1 sussiste l obbligo di non smaltire i RAEE come rifiuti urbani e di effettuare per detti rifiuti una raccolta separata 2 per lo smaltimento vanno utilizzati i sistemi di raccolta pubblici o privati previsti dalla leggi locali inoltre possibile riconsegnare al distributore l apparecchiatura a fine vita in caso di acquisto di una nuova 3 questa apparecchiatura pu contenere sostanze pericolose un uso improprio o uno smaltimento non corretto potrebbe avere effetti negativi sulla salute umana e sull ambiente 4 il simbolo contenitore di spazzatura su ruote barrato riportato sul prodotto o sulla confezione e sul foglio istruzioni indica che l apparecchiatura stata immessa sul mercato dopo il 13 Agosto 2005 e che deve essere oggetto di raccolta separata 5 incaso di smaltimento abu
8. elected parameter and go to the next parameter ESC to return to the previous menu Installer menu screens sii DE To navigate inside the screens UP or DOWN to change the value within the options range ENTER to confirm and move the cursors to the next value ESC to return to the installer menu Type of control Settings type of operation ON OFF or modulating type of signal or probe main probe limit probe unit of measurement amp stop slave offline options range ON OFF modulating External contact External proportional signal External proportional signal and linit probe Humidity probe Humidity probe and limit probe Temperature probe Temperature probe and limit probe parameter Select between NTC 0 1 V 2 10 V 0 10 V default 0 20 mA 4 20 mA 0 135 ohm 135 1 kohm C bar default F psi SI default ifthe pLAN netwaork is offline the slave units stop NO if the pLAN netwaork is offline the slave units continue Operating parameter description range default _ U M options Remote F sensor pressure sensor at end of line for balancing YES NO NO ___ _________l ompressedairsystem o o Max Bir DPSSsSUPe Oto 4 2 1 bar 0t04 1 2 bar 0t09 9 0 0t09 9 0 to allow automatic emptying and periodical YES NO YES washing of the water line alarm relay status setting NO NC NO 3 to 60 10 Specia
9. ference to European Union directive 2002 96 EC issued on 27 January 2003 and the related national legislation please note that 1 WEEE cannot be disposed of as municipal waste and such waste must be collected and disposed of separately 2 the public or private waste collection systems defined by local legislation must be used In addition the equipment can be returned to the distributor at the end of its working life when buying new equipment 3 the equipment may contain hazardous substances the improper use or incorrect disposal of such may have negative effects on human health and on the environment 4 thesymbol crossed out wheeled bin shown on the product or on the packaging and on the instruction sheet indicates that the equipment has been introduced onto the market after 13 August 2005 and that it must be disposed of separately 5 inthe event of illegal disposal of electrical and electronic waste the penalties are specified by local waste disposal legislation Warranty on materials 2 years from the date of production Certification The quality and safety of CAREL products are guaranteed by the Carel ISO 9001 certified design and production system as well as the ce mark L installazione del prodotto deve obbligatoriamente comprendere la connessione di messa a terra usando l apposito morsetto giallo verde in morsettiera Non utilizzare il neutro come connessione a terra The product must be installed with the earthconnected using the s
10. idificatore non sia collegato alla rete elettrica x i BI T B2 out H B2 out H Warning before proceeding disconnec the humidifier from the power supply Fig 2 J2 F on J2 BI RE ou PARTS d limit humidi b i Temperature probe connection m rent temperature and limit humidity probe Collegamento sonda combinata di temperatura e umidit rana connection i A A Collegamento sonda di temperatura T i Ambient temperature and limit Ambient temperature and limit limite MC Cabinet MC Cabinet aa humidity probe humidity probe NT Cabinet MC Sonda temperatura ambiente Cabinet MC Sgnda EMPENN J24 V term G J24 V term G im ambiente e umidit limite GND M GND M pa V term G pa V term G J2 BI out T BI ar ID1 1D7 HB GND M GND M J32 B2 out LT J2 B1 outT J2 B1 out t COM1 COM3 HB B2 out H Temperature probe limit humidity probe connetion ON OFF humidistat connection il ERR f 1 limit hum 2 temperature T Collegamento sonda di temperatura sonda umidit limite Collegamento umidostato ON OFF MC Cabinet probe probe MC Cabinet ON OFF humidistat Cabinet MC 1 sondag 2 sonda temperatura Cabinet MC umidostato ON OFF J24 V term G G ID2 ON OFF Di umid limi GND M M COMI COM Lan to V term G G ID2 ON OFF BI out T GR hield AM GND M M COM1 COM J2 B2 culi _ J2 B1 outT GR schermo x B2 out H Connection of pressure probe at end of air line Connection of drain valve at end of water line C l i MC Cabinet cable pre
11. l functions Washing Automatic periodical washing of the water line to increase the hygiene of the installation Automatic cleaning Nozzle self clean cycles to reduce the frequency of maintenance parameter range default U M parameter range default U M Fnabled YES NO YES washing man autom man 0 to 999 30 min NO YES NO 60 to 999 160 S 1 to 99 6 h Oto 15 10 min NO YES NO 1 to 1000 5 S parameter range default U M select display on main sereen signal Hours rH C F rH l italian English French German Spanish YES NO YES 040000040 rel 1 1 16 12 2014
12. ll interno della maschere UP o DOWN per modificare il valore all interno delle opzioni range ENTER per confermare e spostare il cursore al valore successivo ESC per tornare al menu installatore Tipo di regolazione Impostazioni tipo di funzionamento ON OFF o modulante tipo di segnale o sonda sonda principale sonda limite unit di misura e stop slave offline opzioni range ON OFF modulante n sona Contatto esterno Segnale proporzionale esterno Segnale proporzionale esterno e sonda limite Sonda umidit Sonda umidit e sonda limite Sonda di temperatura Sonda di temperatura e sonda limite Pen sE parametro scegliere tra NTG 0 1 V 2 10 V 0 10 V default 0 20 mA 4 20 mA 0 135 ohm 135 1 kohm C bar default F psi SI default se la rete pLAN offline le unit slave si fermano NO se la rete pLAN offline le unit slave continuano Opzioni arametro descrizione range default U M funzionali ISOPE sensore di pressione di fine linea per autobi SI NO NO lanciamento impianto aria compressa 0 4 2 1 bar 0 4 1 2 bar 0 99 0 0 9 9 0 per permettere lo svuotamente automatico SINO Si e il lavaggio periodico della linea acqua impostazione stato rel allarmi NA NC NA g i 3 60 10 Funzioni speciali pulizia automatica Cicli di autopulizia degli ugelli per ridurre frequenza di manutenzione Lavaggio l
13. pecial yellow green terminal on the terminal block Do not use the neutral for the earth connection CAREL INDUSTRIES HQs Via dell Industria 11 35020 Brugine Padova ltaly Tel 39 0499716611 Fax 39 0499716600 e mail carel carel com www carel com BSEr 1 1 Eee rig Ingressi allarme da dispositivi esterni Cabinet MC Rel non na Rel allarme da trattamento acqua DS Si Rel allarme compressore COMI COM B N Rel allarme flussostato aria COM2 COM GR schermo Contatto di attivazione lavaggio linea acqua Uscita proporzionale 0 10 Vdc Cabinet MC Nole batti ozionalaraggie Cabinet MC Uscite esterno ID7 ON OFF VGO RIF COMI COM 0 10 Vdc Caratteristiche uscita carico massimo TKO TO MA Configurazione Parametri di configurazione Men Installatore Dalla maschera principale premere PROG per accedere al menu principale DOWN per posizionarsi sul menu installatore ENTER per posizionarsi nella password e UP DOWN per inserire la password 77 ENTER per accedere al men selezionato UP DOWN per spostarsi tra i sottomen ENTER per selezionare il parametro e spostarsi tra i parametri UP DOWN per modificare il parametro ENTER per confermare il parametro selezionato e andare al parametro successivo ESC per ritornare al men precedente Maschere del menu installatore Per navigare a
14. sivo dei rifiuti elettrici ed elettronici sono previste sanzioni stabilite dalle vigenti normative locali in materia di smaltimento Garanzia sui materiali 2 anni dalla data di produzione Omologazioni la qualit e la sicurezza dei prodotti CAREL sono garantite dal sistema di progettazione e produzione certificato ISO 9001 nonch ce dal marchio IMPORTANT WARNINGS BEFORE INSTALLING OR HANDLING THE APPLIANCE PLEASE CAREFULLY READ AND FOLLOW THE INSTRUCTIONS AND SAFETY STANDARDS DESCRIBED IN THIS MANUAL AND ILLUSTRATED BY THE LABELS ON THE MACHINE The installation operation and maintenance operations must be performed in compliance with the instructions provided in this manual and the legislation in force All other uses and modifications made to the appliance that are not authorised by CAREL S p A are considered incorrect The conditions ofthe environment and the power supply voltage must comply with the specified values The unit must be installed according to the standards in force regarding the product Liability for injury or damage caused by the incorrect use of the appliance lies exclusively with the user Please note that the unit contains live electrical devices and high pressure components All service and or maintenance operations must be performed by specialist and qualified personnel who are aware of the necessary precautions Disposing of the parts of the humidifier the humidifier is made up of metal and plastic parts I re
15. ssure probe MC Cabinet solenoid valve ollegamento sonda di pressione fine linea aria Collegamento elettrovalvola scarico fine linea acqua B3 white C GO 1 ON OFF Cabinet MC cavo sonda pressione Cabinet MC elettrovalvola D Reiss shed MO NO4 7 Bo circo C GO l VDC black A GR 4 J2 GR schermo NO4 2 1 EI on Vea neo A GR 4 Start compressor and or WTS control Cumulative alarm relay gt Comando per attivazione compressore e o WTS Contatto rel di allarme Cae Quiput MC Cabinet Output Cabinet MC Uscita Cabinet MC Uscita J13 Nes ONORE J14 SZ COM l J13 NO5 ON OFF ia C07 COM C4 COM N07 ON OFF Fig C4 COM NO7 ON OFF GR shield GR shield GR schermo GR schermo Electrical specifications of the relay power 500 VA voltage 250 V current 2 A restitive inductive Caratteristiche elettriche dei contatti 500 VA 250 V 2 A induttivi resistivi luo fl az n 2 MASTER Aa SLAVE 5 Di J11 J11 VIII S UUU 5 Rx Tx Rx Tx GND service carc service carc Laljo la Jt0 Laljo luy10 input 24 V V 50 to 60 Hz max power 40 VA 15 w J1 1243 J2 ACI EI a 3 49 O to ce co iS input 24 V V 50 to 60 Hz max power 40 VA 15 W field ca J1 1243 J2 ARI ERI CA field ca Fig 4 MC Master cabinet J11 MC Slave cabinet pLAN network connection J11 RX TX RX TX J11 RX TX J11 RX TX GND GND Utilizzare cavi bipolari pi terra AWG 20 22