1. 16 4 4 3 Manual by pass connection and Qusar switching OFF without cutting off power to the load i 17 U T PTX 10 01 2003 DT0342 E00 E00 Uso e manutenzione User manual 4 1 USO E MANUTENZIONE USER MANUAL USO E MANUTENZIONE USER MANUAL UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 4 4 4 Riaccensione dell UPS e disinserimento 4 4 4 Resetting UPS and disconnecting del By pass manuale senza interruzione di alimentazione al carico 18 4 4 5 Inserimento del By pass manuale in caso di avaria dell UPS 19 4 5 USO CONIIPC ssi 20 4 6 Pannello remoto opzionale 21 4 7 Manutenzione ordinaria 22 4 7 1 Verifica dell intervento dell UPS 22 4 2 Ricarica della batteria 22 4 7 3 Verifica periodica del funzionamento della linea di riserva 22 4 7 4 Pulizia del mobile del pannello frontale e della griglia di aerazione 23 4 8 Manutenzione periodica 23 4 9 Stati UPS funzionamento norma e ica 24 4 10 Risoluzione dei problemi 26 manual by pass without cutting off power tO NETOA in E ie 18 4 4 5 Manual by pass connection following UPS 2 0 ala 19 4 5 Use with the PC 20 4 6 Remote panel optional
2. 5 1 2 4 ACCESSON ii 6 L24 ACCOSSVI Siria 6 1 3 Principio di funzionamento 1 3 Operation ciccia 7 1 3 1 Stadio di ingresso modulo di potenza e 1 3 1 Input Stage Power Module and Output stadio di uscita eener renee een 7 SAR en ee ree ee eee 7 1 3 2 Schema funzionale dell UPS doppia 1 3 2 UPS functional drawing double conver conv con by pass risaie 8 SION DY PASS ccsscsccssesssccccnsensesecnsensenees 8 1 3 3 Logica e circuiti ausiliari 9 1 3 3 Logic and Auxiliary circuits 9 1 3 4 Batterie 10 1094 Balanos seese 10 1 3 5 Scheda Rel 10 Jao AAV RA 10 1 3 6 By pass manuale 10 1 3 6 Manual by pass 10 1 3 7 Pannello frontale 11 1 3 7 Front panel 0 cccsssseceeeccccssenesssseeeessesnans 11 Rev Descrizione Data Controllato Realizzato Data Tipo di doc Paginen Pag totali U T PTX 20 04 2002 Approvato DT0342 E00 Informazioni generali General overview 1 1 A INFORMAZIONI GENERALI GENERAL OVERVIEW INFORMAZIONI GENERALI GENERAL OVERVIEW N UPS 60 120kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 1 1 DESCRIZIONE GENERALE DELL UPS Le ridotte dimensioni esterne del contenitore nascondono la notevole
3. i UTENZA 1 USER 1 UTENZA 2 USER 2 QUADRO DI DISTRIBUZIONE ALLE UTENZE LOAD DISTRIBUTION PANEL magnetotermico differenziale n magnetotermico differenziale 2 safety safety imagnetothermic n magnetothermic2 presa MAIA presa dea utenza 2 7 utenza n User User socket 2 socket n Fa F F mia gt gt fi UTENZA n USER n Fig 2 4 Quadro di distribuzione alle utenze Load distribution Panel 2 12 Installazione Installation UPS 60 120kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 Collegare il cavo di uscita dell UPS ai morsetti 15 terra 11 12 13 fase e 14 neutro dell interruttore magneto termico Curva C del Quadro di Distri buzione alle utenze Le uscite dell interruttore Curva C devono es sere collegate in parallelo alle prese d utenza si consiglia di realizzare questo collegamento me diante l utilizzo di ulteriori interruttori magnetotermici differenziali uno per ciascuna presa magnetotermici consentiranno se ne cessario di isolare le singole utenze Le caratteristiche degli interruttori magnetotermici da inserire a monte delle utenze cos come la sezione dei cavi dipendono dai carichi previsti sulle varie prese Terminate le operazioni di collegamento montare nuovamente il pannello di protezione alla morsettiera di conness
4. ON BYPASS O ALARM SILENCE CH O POWER ON l sezione 0 6 mm L max 100 m l Morsettiera lato UPS 0 6 sq mm section max L 100 m Morsettiera lato pannello Tagblock UPS side Tagblock panel side Batteria scarica Low batter Comune Common Rete 230 V presente 230V mains ON E i By pass inserito By pass ON UPS ON UPS ON Fig 2 6 Schema del cavo di collegamento al Pannello remoto Drawing showing Remote Panel wiring cable 2 16 Installazione Installation UPS 60 120kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 2 4 SCHEDA RELE OPZIONALE 2 4 RELAY CARD OPTIONAL A richiesta viene fornita una scheda Rel che A Relay card is supplied upon customer de pu essere aggiunta alla scheda Rel standard mand This cardcan be added to the Rel one 1 Eseguire i collegamenti come nello schema 1 Proceed to wire connect as shown on the di figura 2 7 diagram of Fig 2 7 2 Eseguire la predisposizione dei ponticelli 2 Strap presetas reported in the Set up chap come descritto nel capitolo Attivazione ter 1 The Relay card cannot be fitted with an additional EPO button To connect several EPO buttons to UPS first connect them in series and then connect the lot to one of the CN3s non possibile collegare alla scheda Rel un secondo pul
5. 1 11 3 2 1 1 Limitations of liability 3 2 1 2 Material admittance 4 2 1 3 Identification 4 2 1 4 Packing material removal 4 245 SlU ria 6 2 1 6 Siting it in the operative position 7 2 1 7 UPS distribution panel 7 2 2 UPS connection to mains 8 2 2 1 Setting up the three phase primary Supply MAainS siriani 9 2 2 2 Tagblock WIFING 10 2 2 3 User connection 12 2 3 External devices INSTALLAZIONE INSTALLATION SSRN siria 14 connection x 1x 11 gt 14 2 3 1 Collegamento del pulsante per lo 2 3 1 Emergency Power Off E P O push spegnimento forzato E P O 14 button connection 14 2 3 2 Collegamento con il Personal 2 3 2 Connection to Personal CONDUIT ani 15 CONDI 15 2 3 3 Collegamento al Pannello remoto 16 2 3 3 Remote Panel connection 16 2 4 Scheda rele opzionale 17 2 4 Relaycard optional 17 Rev Descrizione Data Controllato Realizzato Data Tipo di doc Paginen Pag totali U T PTX 10 10 2003 Approvato DT0342 E00 Installazione nstallation 2 1 INSTALLAZIONE INSTALLATION
6. AVARIA CARICA BATTERIA GUASTO COMMTATORE STATICO COMMUTATORE STATICO BLOC CATO RETE RISERVA NON IDONEA RETE PRINCIPALE NON IDONEA BY PASS MANUALE INSERITO ARRESTO DI EMERGENZA CAUSA Accensione iniziale Sovraccarico permanente o cortocircuito in uscita Sovraccarico permanente o cortocircuito in uscita Sezionatore di batteria aperto o batteria non collegata Test di batteria fallito Prolungata mancanza rete Batteria vicino alla fine autono mia Possibile guasto su blocco commutatore statico Spunti elevati di corrente del carico Tensione della riserva fuori dai limiti specificati Tensione della rete fuori dai li miti specificati UPS in manutenzione Comando di arresto di emer genza attivato UPS 60 120kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 AZIONE Avviare l Inverter Controllare i carichi collegati in uscita UPS Controllare i carichi collegati in uscita UPS Chiuderesezionatore di batte ria o collegare batteria Controllare la batteria presente Eseguire lo shut down even tuale dei carichi collegati Chiamare il servizio assisten za tecnica per sostituzione Controllare SCR Bypass Verificare il carico collegato e resettare la condizione Controllare la tensione della li nea di riserva Controllare la tensione della li nea principale Verificare causa Spegnere completamente l UPS Per la riaccensione eseguire proce dura paragraf
7. USO E MANUTENZIONE 4 1 Descrizione generale 3 4 2 Il pannello frontale 5 4 3 Quadro elettrico posteriore 14 AA istruzioni per Uso sas 15 4 5 USOGonliPCrrionaie 20 4 6 Pannello remoto opzionale 21 4 7 Manutenzione ordinaria 22 4 8 Manutenzione periodica 23 4 9 Stati dell UPS funzionamento NOMNale sana 25 4 10 Risoluzione dei problemi 27 4 USER MANUAL 4 1 4 2 4 3 4 4 4 5 4 6 4 7 4 8 4 9 4 10 General OVERVIEW snxcsecsecsucsis ius iic iiss 3 Front panel vio tsuiuniuna ss Rear distribution panel 14 USCers glioeistscssiane na nananana 15 Use with the PC 20 Remote panel optional 21 Routine maintenance 22 Periodic maintenance 23 UPS status normal mode 25 Troubleshooting 27 Il Indice generale Table of contents UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 di PREMESSA FOREWORD A 1 Pronto soccorso Vi Al FISAS soil V Spegnimento in emergenza V Emergency Power Off V Persone colpite da scarica elettrica V Fi
8. the table below applies Q descritta nella tabella che segue Li Y a FUNZIONE CHIUSI APERTI Lu FUNCTION CLOSED OPEN EPO abilitata J15 J12 J16 T N EPO enabled Er lt z gt EPO non abilit J12 J15 J16 ar EPO not enabled lt Da SERAL Scheda Rel predisposizioni E P O Relay card E P O setting Ponticelli sulla scheda Rel Setting options on the Relay card Attivazione Setup 3 7 UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 3 2 2 Predisposizioni per la comunica ATTIVAZIONE SETUP zione con il PC Come spiegato nelle pagine precedenti l UPS pu comunicare ad un computer il proprio stato e le misure sul suo funzionamento Tale comu nicazione pu essere di due tipi seriale avanza tao seriale basica In funzione di quale si intende usare e quindi dicome sie settato sia il firmware dell UPS che le schede di comunicazione pre senti sul retro in fase di installazione del software si deve scegliere la voce esatta dall elenco a tendina L UPS quando esce dalla fabbrica predisposto per usare la comunicazione pi ricca e questa porta a scegliere come modello di UPS nel software di gestione SQP3 3ph Nel caso per esigenze particolari il cliente desi deri usare la comunicazione basica dopo aver opportunamente configurato la scheda sul retro e il firmware di gestione d
9. Sequenza di spegnimento dell UPS 7 aprire l interruttore INPUT MAINS 4 8 Attendere lo spegnimento completo dell UPS 5 close the external battery switch 6 close INPUT RESERVE switch 7 close OUTPUT switch 4 4 2 UPS switching off Warning the following instructions permit to switch OFF without having to keep the load supplied Refer to paragraph below reporting all those circumstances whereby UPS has to be excluded while still keeping load supplied Toswitch UPS offproceed to operate the switches following the order giveb below 1 press the MENU pushbutton 1 2 Choose the COMMAND MODE menu using the arrows lt 3 or gt 4 and press ENTER pushbuttons 3 and 4 togheter to confirm 3 Choose INVERTER ON OFF using the arrows lt 3 or gt 4 and press ENTER pushbuttons 3 and 4 togheter to confirm OFF procedure 4 Open the OUTPUT switch 1 5 Open the external battery isolator and inner battey fuses 2 6 open the INPUT RESERVE switch 3 Switching ON sequence 7 open the INPUT MAINSswitch 4 8 Wait the complete OFF status of the UPS 4 16 Uso e manutenzione User manual UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 4 4 3 Inserimento del By pass manuale e spegnimento dell UPS senza interruzione di alimentazione al carico In tutti i casi in cui occorra fermare ed escludere l UPS mantenendo alimentato il carico occorre
10. Storing Should the equipment not be installed im mediately it must be stored in a room so as to protect it against excessive humidity and against very high heat sources i e 5 to 40 T and humidity not lower than 95 and moistureless If battery cubicle is supplied make sure that not more than 6 months pass from the time the battery had last been recharged After such period temporarily connect the UPS to mains and activate it for the time required to recharge the batteries Refer to para 2 5 Temporary connection to enable battery recharge 2 6 Installazione nstallation UPS 60 120kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 2 1 6 Collocazione nella posizione operativa L UPS dotato di ruote che permettono di posizionarlo facilmente nel luogo pi adatto La posizione scelta deve garantire comodit di allacciamento spazi sufficienti per un agevole operativit sull UPS anche in previsione degli interventi di manutenzione periodica e straordinaria ricambio di aria sufficiente a smaltire il calo re prodotto dall UPS protezione dagli agenti atmosferici protezione dall eccessiva umidit o da fonti di elevato calore protezione da polvere rispetto delle norme antincendio vigenti ambiente operativo a temperatura compre sa tra 20 e 25 C in questo campo di temperature si ha la massima efficienza delle batterie
11. quest ultima dispone di una morsettiera con contatti liberi da tensione che ripete i medesimi segnali del connettore DB9 Con la scheda Rel possibile perci pilotare oltre a PC Pannello remoto ogni tipo di dispositivo allarmi sonori lampade telesegnalazioni ecc 0 non possibile collegare alla scheda un secondo pulsante EPO Se occorre comandare lo spegnimento forzato dell UPS da pi pulsanti EPO necessario collegarli in serie tra loro e collegare infine la serie all ingresso di uno dei connettori CNS 1 3 6 By pass manuale Il By pass manuale previsto per i casi in cui occorra escludere l UPS mantenendo alimentato il carico da rete es Ups fermo avaria Si tratta di un circuito azionabile tramite l interruttore MANUAL BY PASS che si trova nella parte anteriore dell UPS L interruttore normalmente aperto con levetta in posizione orizzontale dis pone di un fermo meccanico di protezione per impedire che venga azionato inavvertitamente Il fermo meccanico inoltre bloccabile con un lucchetto per evitarne la rimozione da personale non autorizzato 1 3 7 Pannello frontale L UPSviene gestito attraverso ilpannello frontale dal quale possibile comandare manualmente il funzionamento su linea di riserva e resettare circuiti d allarme il pannello dotato di una completa serie di LED che consentono di visualizzare lo stato di funzionamento dell Ups lo stato del carico e ogni condizione d all
12. si consiglia l installa zione di un dipositivo da almeno 500mA In caso di incendio All interno del Sistema di Continuit sono presenti tensioni pericolose anche con tutti gli interruttori aperti Pertanto in caso di incendio nei locali d in stallazione non utilizzare acqua per lo spe gnimento del fuoco Addestramento del personale Tutto il personale deve essere addestrato ad eseguire lo spegnimento in emergenza vedere 1 Pronto soccorso A 3 SAFETYINSTRUCTION Before starting installation To completely isolate the equipment the switches ON OFF INPUT MANUAL BY PASS e OUTPUT mustbe switched off all the lever switches orizontal the input sup ply and external battery supply should be isolated from the UPS Remove all the fuses in the Auxiliary Battery cabinet and or open battery isolator Installation This equipment must be installed by quali fied personnel following instruction given in chapter 2 Installation High leakage current Connect protective earth before power Supply cables Earth leakage protection This device has a high leakage current towards protective earthing The maximum earth leakage current is 300 mA When setting the threshold of the earth leakage circuit breaker installed upstream from this equipment consider this amount of current and the current amount due to the loads It is suggested to install a protection device of at least 500MA In case of fire Inside the Uninterrupti
13. ta nella seguente tabella 2 2 1 Setting up the three phase pri l mary supply mains Before connecting the UPS check that the mains voltage and frequency values are as those indicated on the adhesive label attached on the rear plane of the UPS input voltage working frequency plant grounding fully complies either with IEC norms or local laws Afterwards start installing the four pole magnetothermic switches both at the input and output of the UPS see Fig 2 2 The switches feature capacity equal or greater than that reported on the label situated on the UPS rear plane KVA characteristics compliant either with IEC norms or local laws for Curve C magnetothermic switches Connecing cables must have a suitable lenght to allow the cubicle to advance at least 80cm for lateral and back accessibility in case of mantainance Wiring must be flexible cable with the section as suggested in the following table 2x70 mm 2x 2x50 mm 60kVA 80kVA 100KVA 120KVA 5x25 mm 5 x 35 mm 5 x 50 mm 5 x 70 mm 2x 2x70 mm 2x 2x70 mm Installazione Installation 2 9 INSTALLAZIONE INSTALLATION UPS 60 120kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 i 2 2 2 Collegamenti alla morsettiera INSTALLAZIONE INSTALLATION LE OPERAZIONI DESCRITTE IN QUESTO PARAGRAFO DEVONO ESSERE ESEGUITE DA ELETTRICISTI AUTORIZZATI O DA PER SONAL
14. 2 SETTING OPTIONS The presettings required are only those which concern the interfaces wiring the external de vices i e personal computer safety switch remote panel 3 6 Attivazione Setup UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 3 2 1 Predisposizioni sulla scheda rel 3 2 1 Setting options on the Relay card La scheda Rel fornita opzionalmente a richie The relay card is optionally supplied upon cus sta Se presente la scheda deve essere predi tomer demand If supplied the card shall have to sposta secondo l uso desiderato dal Cliente be preset according to specific Customer re quirements Le configurazioni dei ponticelli perl usoconilPC The strap configuration adopted for the applica o con il pannello di segnalazione remoto sono tion with PC or with the remote indication panel is descritte nella tabella che segue described in the following table Scheda Rele Relay Card FUNZIONE FUNCTION CHIUSI CLOSED APERTI OPEN Uso con il PC contatti J5 J7 J8 J9 J10 J11 J14 J1 J2 J3 J4 J6 Use with the PC contact Uso con il PC seriale J1 42 43 45 J7 48 J9 J10 J11 414 Use with the PC serial Quando richiesto il collegamento con un pul When a connection with the E P O of the UPS sante per lo spegnimento in emergenza del sestablished the strap configuration reported in UPS E P O la configurazione dei ponticelli
15. 21 4 7 Routine maintenance 22 4 7 1 Check on UPS intervention 22 4 7 2 Battery recharge rr 22 4 7 3 Routine operating check on the reserve I ll 22 4 7 4 Cabinet Front panel and ventilation grid CCNI rit 23 4 8 Periodic maintenance 23 4 9 UPS status normal mode 25 4 10 Troubleshooting 27 4 2 Uso e manutenzione User manual UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 4 1 DESCRIZIONE GENERALE L UPS realizzato in un contenitore che presenta nella parte frontale un motivo estetico dalle curve morbide sulla sommit del quale inserito il pannello dei comandi e delle segnala zioni Vista frontale Front view 4 1 GENERAL OVERVIEW UPS consist of a cabinet featuring a finely M signed frontcoverplate with flowing line mounting the command and indication panel In the rear of the door are contained the various Nella parte anteriore in posizione volutamente nascosta dalla porta per impedire manovre acci dentali si trovano i vari interruttori di manovra Nella parte posteriore vi sono due aperture da cui si affaccia un connettore dB9 standard usato per collegare l UPS a un PC che con un programma fornito su richiesta permette di gestire il funzio namento dell UPS Alla morsettiera applicata sulla stessa scheda pu essere collegato un panne
16. Grado di protezione IP20 a lEC529 IEC 944 Rumorosit a 1m di distanza lt 60 dBA lt 60 dBA lt 65 dBA lt 65 dBA Temperatura funzionamento da 0 a 40 C Temperatura immagazzinamento 20 a 70 C batterie escluse Umidit relativa di funzionamento lt 95 UR senza condensa Altitudine senza declassamento 1000m s l m Peso 230Kg 260Kg 290Kg 340Kg Dimensioni LarghezzaxProfondit xAltezza 00x750x1350 mm Compatibilit Elettromagnetica EN50091 2 classe A IEC801 2 IEC801 3 IEC801 4 Norme di riferimento IEC 146 4 EN50091 1 IEC 950 Raddrizzatore e Carica batteria Tensione nominale ingresso 3ph N da 380V a 415 Vac Variazione tensione ingresso 330Vac a 480Vac Frequenza ingresso 50 60 Hz Variazione ammessa frequenza ingresso 40 70 Hz Distorsione armonica tot corrente ingresso Standard lt 35 Optional lt 10 Fattore di potenza ingresso standard 0 95 Corrente Max assorbita con tensione di 400Vac 107A 137A 166A 200A Soft start 10 sec Tensione uscita del carica batteria Tampone 432Vdc 432Vdc 432Vdc 545Vdc Rapida In funzione del tipo di batteria Stabilit della tensione del carica batteria 1 Residuo alternato tensione continua lt 1 Vrms Vb x 100 Massima corrente di ricarica 20A 20A 20A 30A Campo di taratura limitazioni 7 20A 7 20A 7 20A 10 30A Caratteristiche di ricarica DIN 41773 Tampone compensato in temperatura per batterie ermetiche Batteria Numero di celle Piombo ermetico 192 192 192 240 Piombo vaso aper
17. UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 2 5 Allacciamento provvisorio per la 2 5 Temporary connection to enable ricarica delle batterie 18 battery recharge 18 2 5 1 Verifiche e predisposizioni 18 2 5 1 Tests and setting options 18 2 5 2 Esecuzione dei collegamenti iS 20543 WiN essi eer eee 19 2 2 Installazione nstallation UPS 60 120kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 2 1 INTRODUZIONE Questo manuale fornisce tutte le informa zioni relative all interfacciamento meccanico ed elettrico dell UPS per consentirne la sua corretta installazione In questa parte trovano quindi posto tutte le procedure per il corretto disimballaggio del ma teriale per il suo posizionamento e successiva mente per il corretto collegamento LE OPERAZIONI DESCRITTE IN QUESTO MANUALE DEVONO ESSERE ESEGUITE DA ELETTRICISTI AUTORIZZATI O DA PERSO NALE TECNICO QUALIFICATO 2 1 1 Responsabilit Il costruttore declina ogni responsabilit da eventuali danni agli apparati ed alle per sone causati a seguito di errati collegamenti o di manovre non espressamente descritte 2 1 INTRODUCTION To properly install UPS all information con cerning its mechanical and electrical interfacing is supplied inside this
18. attivare il By pass manuale rispettando la se guente procedura 1 premere il pulsante 1 MENU 2 Selezionare il menu COMANDI con le frecce lt 3 o gt 4 e premere ENTER tasti 3 e 4 contemporaneamente per conferma 3 Selezionare COMMUTAZIONE CARICO con le frecce lt 3 o gt 4 e premere Sequenza di inserimento del By pass manuale e spegnimento dell UPS Manual by pass connection and UPS switching OFF ENTER tasti 3 e 4 contemporaneamente 4 verificare l avvenuta commutazione 5 togliere l eventuale fermo mecc sull interrut tore MAN BY PASS e chiudere l interruttore verificare l accensione del LED rosso di allarme 6 aprirel interruttore OUTPUT 6 7 Aprire il sezionatore esterno di batteria ed estrarre i fusibili di batteria 7 8 aprire l interruttore INPUT RESERVE 8 9 aprire l interruttore INPUT MAINS 9 carico ora alimentato dalla sola rete attraverso il By pass manuale a bordo dell UPS 4 4 3 Manual by pass connection vnc UPS switching OFF without cutting off power to the load Inallthose circumstances where UPS has to be Stopped and excluded while still keeping the load powered it willbe necessary to activate the manual by pass following the given procedure 1 press the MENU pushbutton 2 Choose the COMMAND MODE menu using the arrows lt 3 or gt 4 and press ENTER pushbuttons 3 and 4 togheter to confirm 3 Choose SWITCH LOAD using th
19. batterie Le batterie devono essere separate da tutte le altre parti dell UPS e smaltite secondo le norme che regolano lo smaltimento di rifiuti tossici e NOCIVI Smaltimento di ulteriori parti Ulteriori parti costituenti l UPS come guarnizioni in gomma parti in plastica e cablaggi sono da affidare a ditte specializzate nello smaltimento di rifiuti Industriali A 4 DISMANTLINGAND DISPOSAL Shouldthe UPS be dismantled the parts making it up must be assigned to Companies special Ised In the disposal and recycling or industrial waste specifically Disposal of packing Packing consists of biodegradable material The cardboard can be sent to Companies assigned to recuperating cellulose Polyurethane foam protective profiles are chemi cally inert they do not contribute to gas forming nor to pollute water their disposal can be as signed to Companies specialised in the disposal of industrial materials Disposal of metal parts The metal parts of the cabinet both the var nished ones and the stainless steel ones are regularly recovered by companies specialised in the scrapping of metals Disposal of electronic cards It is mandatory that the electronic cards be disposed of companies specialised in the dis posal of electronic components Disposal of batteries Batteries must be separated from any other part ofthe UPS and disposed according to the norms locally current about disposal of toxic and nox ious industrial mater
20. e Next visualizzano le lingue disponibili nei menu Orologio e Numero di telefono tramite Il tasto Back si incrementa la cifra mentre Next decrementa le cifra ontrol pane The panel displays the equipment s operating state MENU pushbutton ESC pushbutton BACK pushbutton NEXT pushbutton 4 ENTER function Green light ON to indicate UPS normal operation Red light ON to indicate UPS general alarm LCD display to display the UPS functions and parameters 4 2 3 BACK and NEXT pushbuttons The Back 3 and Next 4 pushbuttuons have different functions depending of submenu Pressing togheter the pushbuttons it is made the operation confirm ENTER function Inside the Event History menu Back scroll the event date and time only Next display the event set date and time with the status and alarm inside the Operating language menu Back and Next display the available languages inside the Clock and Telephone number menus Back increase the number Next decrease the number to set 4 6 Uso e manutenzione User manual UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 4 2 4 Spia NORMAL La spia di colore verde indica il normale funzionamento dell UPS 4 2 5 Spia ALLARME GENERICO Questa spia si accende per ogni situazione di allarme o guasto L attivazione di questa spia sempre correlata ad un allarme acustico silenziabile premendo
21. e allarmi di un determinato evento MENU STATI ALLARMI STORICO EVENTI F ma e 00 00 00 00 00 00 evento x a Cancella tutti gli eventi ENZIONE USER MANUAL Premendo il tasto MENU all interno del menu VISUALIZZA EVENTI in qualsiasi posizione il gt display visualizzer l ultimo evento avvenuto Per cancellare tutto lo storico eventi selezionare CANCELLA EVENTI nel menu e confermare con il comando ENTER Q Si consiglia di utilizzare questa azione di cancel lazione dello storico solo in casi di necessit EVENTHISTORY inthis menu the usercan see and scroll the last 500 events occurred in chronological order It is possible to display the EVENTS by pressing ENTER in menu DISPLAY EVENT The display will show date and time of the last event Pressing BACK pushbutton will be possible to scroll the events date and time pressing NEXT pushbutton will be possible to see the status and alarms of a defined event STATUS ALARM MENU EVENT HISTORY F O k 00 00 00 00 00 00 events F 4 Delete all events Pressing MENU pushbutton inside the DISPLAY EVENT menu the display will show always the last event To Erase allthe events stored in memory choose CANCEL EVENTS and confirm with the ENTER command tis suggested todo this action only ifnecessary 4 10 Uso e manutenzione User manual UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue
22. escludere PUPS mantenendo alimentato il carico Per la verifica procedere come segue 1 premere il pulsante 1 MENU 2 Selezionare il menu COMANDI con le frec ce lt 3 o gt 4 e premere ENTER tasti 3 e 4 contemporaneamente per conferma If no other events arise the UPS will automati cally revert to regular operation after 20 sec onds 3 1 7 Manual By pass operation check The manual by pass allows to exclude the UPS while stillkeeping the load powered The check is carried out in the following manner 1 press the MENU pushbutton 1 2 Choose the COMMAND MODE menu using the arrows lt 3 or gt 4 and press ENTER keys 3 and4 together to confirm Attivazione Setup 3 5 ATTIVAZIONE SETUP UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 3 Selezionare COMMUTAZIONE CARICO ATTIVAZIONE SETUP con le frecce lt 3 0 gt 4 e premere ENTER tasti 3 e 4 contemporaneamente per con ferma Ora il carico su bypass 4 Selezionare INVERTER ON OFF con le frecce lt 3 0 gt 4 e premere ENTER tasti 3 e 4 contemporaneamente per conferma spegnimento L allarme generico si attiver 5 verificare la segnalazione dell LCD di Cari 3 Choose SWITCH LOAD using the arrows lt 3 or gt 4 and press ENTER pushbuttons 3 and 4 together to confirm Now the load is on bypass 4 Choose INVERTER
23. il tasto di tacitazione ESC 4 2 6 MENU PANNELLO DI COMANDO La tabella seguente mostra livelli del menu principale MENU STATI ALLARMI in questo menu possibile vedere lo stato e le condizioni operative dell UPS il tasto ESC ha la funzione di scorrimento nella visualizzazione degli stati allarmi Da questo menu l utente pu avere acceso ai diversi menu premendo il pulsante MENU se condo livello Una volta entrati al secondo livello la prima riga MENU STATI ALLARMI PARAMETRI UPS MODO COMANDI STORICO EVENTI LINGUAGGIO OPERATIVO OROLOGIO CONFIGURAZIONE UPS 4 2 4 NORMAL LIGHT The green light inicates the UPS normal status 4 2 5 ALARM LIGHT This light it is on every time that an alarm or fault condition occur The turning on of this light is always associated with the activation ofa buzzer which can be silent using ESC pushbutton 4 2 6 CONTROL PANEL MENU The table below show the main menu levels STATUS ALARM MENU inside this menu it is possible to see the status and the operative conditions of the UPS the ESC pushbutton has the function to scroll the display status alarm From this menu the usercan access to different submenu by pressing MENU pushbutton second level Once on the second level the first row show STATUS ALARM MENU UPS PARAMETERS COMMAND MODE EVENT HISTORY OPERATING LANGUAGE CLOCK UPS CONFIGURATION Uso e manutenzione User m
24. la rete di ingresso e verifican do che il carico continui ad essere alimentato Procedere come di seguito descritto 3 1 4 UPS Mains failure test The UPS intervention or MAINS BATTERY switching test is carried out by cutting off the input mains and checking that the load is still beingpowered Proceed as stated below Prova di intervento Intervention test 1 Aprire l interruttore INPUT MAINS e verificare a allarme acustico in funzione b LED rosso ALARM 6 acceso c Allarme sull LCD Rete principale non idonea 2 Premere il tasto ESC 2 per escludere l allarme acustico zn mi i 1 ope alte Pe fe yp FI 1 Open the INPUT MAINS switch lever and check that a the buzzer alarm is operating b the red ALARM LED 6 is glowing c alarm on LCD mains line out of limits 2 Press ESC key 2 to clear the buzzer alarm 3 1 5 Prova dello stato di carica della batteria Mantenendo il carico alimentato solo da UPS interruttore INPUT MAINS leva orizzontale verificare sul pannello frontale LCD i parametri relativi alla batteria Vbatt batt Autonomia La condizione normale quella di avere la V batt compresatrai 370 430Vdc e l Autono mia compresa tra 90 100 valori indicativi in funzione del carico applicato La condizione di PREALLARME FINE SCA RICA quella la V batt a 350Vdc 2 La condizione di BATTERIA NON IDONEA a
25. manual This section reports all the procedures re quired to properly unpack the material to site it and afterwards to properly wire connecting it ALL THE OPERATIONS DESCRIBEDINTHIS MANUAL MUST BE EXECUTED BY AUTHOR IZED ELECTRICIANS OR BY QUALIFIED TECHNICAL PERSONNEL 2 1 1 Limitations of liability The constructor shall not be liable for consequential damages to the equipment or person based on wrong connections or op erations non specifically set forth Installazione Installation 2 3 Di INSTALLAZIONE INSTALLATION UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 i 2 1 2 Ricevimento del materiale INSTALLAZIONE INSTALLATION All atto della ricezione verificare che il mate riale non abbia subito danneggiamenti durante il trasporto ispezionare perci accuratamente i contenitori e dopo la rimozione dell imballo il perfetto stato del contenuto Successivamente assicurarsi che il mate riale fornito corrisponda a quanto indicato sulla bolla d accompagnamento 2 1 3 Identificazione gruppi forniti sono identifi 2 1 2 Materialadmittance When receiving the material check for dam ages that it might have suffered during transpor tation Therefore properly inspect the packing case and after having removed the packing material check that the contents are in perfect condition Afterwards ascertain that the material sup plied is a
26. minimum time to intervene must be 500 mA Fig 2 2 Schema di principio per l installazione dell UPS UPS installation schematic alle utenze To users 2 8 Installazione nstallation UPS 60 120kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 2 2 1 Preparazione della rete d alimen tazione primaria trifase Prima di procedere al collegamento dell UPS necessario verificare che i valori della tensione e della frequenza di rete corrispondano a quelli indicati sull etichetta adesiva presente sulla parte posteriore dell UPS tensione di in gresso frequenza di lavoro verificare chela messa a terra dell impianto sia rigorosamente conforme a quanto previ sto dalle norme IEC o del luogo vigenti Successivamente procedere all installazio ne a monte e a valle dell UPS di interruttori magnetotermici quadripolari vedi Fig 2 2 aven ti le seguenti caratteristiche portata uguale o maggiore di quella indicata sull etichetta presente sulla parte posteriore dell UPS KVA Caratteristiche conformi a quanto previsto dalle norme CEI o del luogo vigenti per i magnetotermici Curva C cavi di collegamento devono avere una lunghezza tale da permettere l avanzamen to dell UPS di almeno 80cm per l accessibi lit laterale e posteriore in caso di manuten zione collegamenti devono essere realizzati uti lizzando cavi flessibilicon sezione come indica
27. off completely the UPS To restart follow the procedure on paragraph 3 1 1 onuser manual USO E MANUTENZIONE USER MANUAL Documento DT0340 Rev 02 21 01 2003 Specifica Tecnica ATLAS 60 120 kVA SHT POWER ATLAS 60 120 KVA Description ISSUED DT 0340 E02 Date 21 01 2003 21 01 2003 Approved La SHT POWER si riserva i diritti di modificare i dati del presente documento senza alcun preavviso Pag 1 11 DT 0340 E02 Documento DT0340 Rev 02 21 01 2003 Specifica Tecnica ATLAS 60 120 kVA Introduzione La presente specifica definisce le caratteristiche tecniche di una famiglia di UPS SHT POWER trifasi di media potenza denominata ATLAS nel range da 60 a 120kVA resi Tale famiglia di apparecchiature contraddistinta da un ingombro molto ridotto e da un elevato rendimento grazie alla tecnologia di conversione adottata che non necessita di trasformatori di adattamento o separazione tra la rete l invertitore e il carico Tali UPS si possono collocare tra le macchine a doppia conversione con i vantaggi che tale tipologia comporta senza peraltro essere penalizzate nel rendimento di sistema Come per gli altri prodotti SHT POWER sono disponibili opzioni per accrescere il livello di presrazioni sia a livello di potenza quali _Riduzione delle armoniche della corrente assorbita da rete _Isolamento del carico tramite trasformatore _Isolamento della rete d ingresso lato inverter e o lato riserva
28. prevent unauthorized personnel from removing it 1 3 7 Front panel The UPS operation is managed through its front panel Through it operation can be manually driven onto the reserve line and the alarm cir cuits to be reset The panel comprises a com plete series of LEDs indicating the operating state of Ups the state of the load and any other alarm state A thorough description of the Front Panel is given in chapter 4 Use and Mainte nance to which reference should be made 1 10 Informazioni generali General overview UPS 60 120kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 2 INSTALLAZIONE Indice 2 1 Introduzione ccccecsecncsssncecssseeess 3 2 1 1 Responsabilit 3 2 1 2 Ricevimento del materiale 4 2 1 3 Identificazione 4 2 1 4 Rimozione dell imballo 4 2 1 5 Immagazzinamento 6 2 1 6 Collocazione nella posizione operativa 7 2 1 7 Quadro elettrico dell UPS 7 2 2 Allacciamento dell UPS alla rete 8 2 2 1 Preparazione della rete di alimentazione primaria trifase 9 2 2 2 Collegamenti alla morsettiera 10 2 2 2 Allacciamento delle utenze 12 2 3 Allacciamento a dispositivi Di 2 INSTALLATION Table of contents 2 1 Introduction
29. sia a livello di supervisione quali _ Connesione a PC e o a rete locale _Interrogazione gestione remota dello stato del UPS _Telesegnalazioni isolate di stati e allarmi SCHEMA A BLOCCHI UPS ATLAS I3 BY PASS DI EMERGENZA RETE DI RISERVA RETE DI ALIMENTAZIONE CARICA BATTERIE i ARMADIO BATTERIA fine La SHT POWER si riserva i diritti di modificare i dati del presente documento senza alcun preavviso Pag 2 11 Documento DT0340 Rev 02 21 01 2003 Specifica Tecnica ATLAS 60 120 kVA Gli UPS della famiglia ATLAS sono macchine a ventilazione forzata alloggiate in un armadio metallico armadio batteria separato Tutte le taglie sono contenute nella medesima carpenteria Di seguito viene riportata una foto dell apparecchiatura La SHT POWER si riserva i diritti di modificare i dati del presente documento senza alcun preavviso Pag 3 11 Documento DT0340 Rev 02 21 01 2003 Specifica Tecnica ATLAS 60 120 kVA Caratteristiche generali Doppia conversione controllo digitale senza trasformatore Pannello di comando a LCD con misure e allarmi con EPO integrato Predisposizione per EPO remoto Possibilit di connessione con PC Connettore RS232 9 vie tipo D Software sviluppato per le pi comuni piattaforme WINDOWS NOVELL UNIX 05 2 Possibilit di interrogare e controllare UPS via modem Meccanica sviluppata in linea con lo stile SHT POWER Accessibilit alle parti critiche dal fronte Entrata cavi d
30. switch 4 3 3 MANUAL BY PASS switch The switch is normally set to open position By pass excluded The switch is protected against unintentional operations through a mechanical lock wich can be additionally provided with a pad lock for fur ther protection It is utilized in all those circum stance whereby UPS has to be excluded while still keeping the load powered from mains 4 3 4 UPS OUTPUT switch This switch connects the UPS output to the load 4 14 Uso e manutenzione User manual UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 4 3 5 Sezionatore fusibili BATTERY Consente la connessione della batteria verso interno dell UPS Questi fusibili sezionabili pos sono essere aperti o chiusi solo con sezionatore sul quadro batteria aperto in quanto non sono organi di manovra sottocarico quindi servono solo alla messa in sicurezza dell UPS durante le manutenzioni 4 4 ISTRUZIONI PER L USO 4 4 1 Accensione dell UPS Gli interruttori d accensione dell UPS si trovano dietro la porta e in condizione di spegnimento sono tutti in posizione orizzontale Prima di attivare l UPS verificare che l interrutto re MANUAL BY PASS sia bloccato in posizione orizzontale da un fermo meccanico e eventuale lucchetto di sicurezza Per attivare l UPS azionare gli interruttori come da sequenza sotto indicata ATTENZIONE l interruttore di bypass 2 deve essere aperto ed i fusibili d
31. togheter to confirm 3 Choose INVERTER ON OFF using the arrows lt 3 or gt 4 and press ENTER Switching ON sequence oushbuttons 3 and 4 togheter to confirm inverter and fans will start 4 Press ESC pushbutton to exit from COMMAND MODE menu to visualize the status and alarm menu Uso e manutenzione User manual 4 15 USO E MANUTENZIONE USER MANUAL y USO E MANUTENZIONE USER MANUAL UPS 60 120kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technicalhandbook DT0342 Issue 00 5 chiudere il sezionatore esterno di batteria 6 chiudere il sezionatore INPUT RESERVE 7 chiudere il sezionatore OUTPUT 4 4 2 Spegnimento dell UPS Attenzione le istruzioni seguenti permettono di spegnere l UPS senza mantenere alimentato il carico in tutti casi in cui occorra escludere l UPS mantenendo alimentato il carico vedere il paragrafo successivo Per lo spegnimento dell UPS azionare gli inter ruttori come da sequenza sotto indicata 1 premere il pulsante 1 MENU 2 Selezionare il menu COMANDI con le frecce lt 3 o gt 4 e premere ENTER tasti 3 e 4 contemporaneamente per conferma 3 Selezionare INVERTER ON OFF con le frecce lt 3 0 gt 4 e premere ENTER tasti 3 e 4 contemporaneamente per lo spegnimento 4 abbassare la levetta dell interruttore UPS OUTPUT 1 5 Sezionare la batteria all esterno ed estrar re i fusibili BATTERY 2 aprire l interruttore INPUT RESERVE 3
32. 00 LINGUAGGIO OPERATIVO sono di OPERATING LANGUAGE aisi sponibili cinque lingue in questo menu Per sele in this menu are five languages To select the zionare la lingua desiderata entrare nel menu desidered language enter in menu LINGUAGGIO OPERATIVO scegliendo la lin OPERATING LANGUAGE choosing the gua con il tasto NEXT Una volta scelta confer language using NEXT pushbutton When mare con il comando ENTER selected confirm with ENTER command MENU STATI ALLARMI STATUS ALARM MENU LINGUAGGIO OPERATIVO OPERATING LANGUAGE ITALIANO si ITALIAN SISI Li ao OF per confermare to confirm INGLESE a ENGLISH a per confermare to confirm FRANCESE nia FRENCH 1a OF i per confermare to confirm TEDESCO GERMAN o nn a per confermare to confirm Moan he SPAGNOLO SPANISH per confermare ee to confirm USO E MANUTENZIONE USER MANUAL Uso e manutenzione User manual 4 11 USO E MANUTENZIONE USER MANUAL OROLOGIO il menu permette all uten te di cambiare la data e l ora impostate sull UPS Per selezionare la Data o Ora premere NEXT dal menu OROLOGIO poi premere ENTER per la modifica MENU STATI ALLARMI per impostare la data 170 F gt on lt 00 00 00 per impostare l ora Quando la Data o l Ora sono visualizzate il cursore sar sopra la prima cifra a destra Per incrementare o diminuire la cifra usare i tasti NEXT e BACK perspostare a sinistra il curs
33. 2 to quench the alarm 4 7 2 Battery recharge The batteries are automatically recharged through the mains voltage and while keeping UPS switched ON Ifthe battery is flat due to abnormal conditions i e mains cut off for a long period it is suggested to recharge the battery during dead working hours e g evening closing time and with the loads switched off 80 of the maximum charge level is reached after approx 10 12 recharging hours 4 7 3 Routine operating check on the reserve line This test is carried out on a monthly basis transfer the load on automatic bypass and check that the load is being powered The operation should follow the procedure de scribed in paragraph 3 1 6 If no other events arise UPS will automatically revert to regular operation after 20 seconds 4 22 Uso e manutenzione User manual UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 4 7 4 Cabinet Front panel and li 4 7 4 Pulizia del mobile del pannello frontale e della griglia di aerazione Con un panno spolverare il mobile e il pannello frontale per la pulizia della griglia di aerazione usare un pennello e un aspirapolvere ATTENZIONE Non utilizzare spugne o strofinacci imbevuti di acqua o altri liquidi n sul mobile dell UPS n nelle immediate vicinanze dello stesso 4 8 MANUTENZIONE PERIODICA Per garantire una protezione costante ed efficente del carico si raccomanda una manutenzion
34. 4 4 3 Inserimento del By pass ma nuale e spegnimento dell UPS senza in terruzione di alimentazione al carico Cap 4 8 Risoluzione dei problemi Personale richiesto tecnici generici Come usare il PC collegato all UPS Consultare il manuale fornito a corredo del pro gramma UPS MANAGEMENT SOFTWARE Personale richiesto personale con esperienza nell uso di strumenti informatici Cosa significano le spie del Pannello remoto Consultare Cap 4 Uso e manutenzione 4 6 Personale richiesto generico Come fare in caso di allarme Consultare Cap 4 8 Risoluzione dei problemi Personale richiesto generico Per avere informazioni di tipo tecnico com merciale sull UPS Consultare Cap 1 Informazioni generali e caratteristi che tecniche The UPS is failed what to do Refer to the following documents Chapt 4 4 3 Manual by pass connection and UPS switching OFF without cutting off power to the load Chapt 4 8 Troubleshooting Personnelhequied supporttechnran How to use the PC connected to the UPS Refer to the instructions supplied with the UPS MANAGEMENT SOFTWARE Personnel required experienced with Personal Computers and relevant applications What do the Remote panel lamps mean Refer to the following documents Chapt 4 User manual 4 6 Personnel required anyone can do that How to proceed when the UPS is alarmed Refer to the following documents Chap
35. AGRAPHS THAT FOLLOW MUST BE CARRIED OUT BY AUTHORIZED ELECTRI CIANS OR BY TECHNICAL PERSONNEL 2 5 1 Tests and setting options Before wire connecting the UPS check 1 the mains voltage and frequency values these must correspond to those indicated on the adhesive label attached on the rear plane of the UPS input voltage working frequency 2 magnetothermic switch capacity must be equal or greater than that reported on the label situated on the UPS rear plane KVA 3 plant grounding must fully comply either with IEC norms or local laws As far as the installation personnel s safety is concerned make sure that the wiring operations are carried out under the following conditions primary mains voltage cut off UPS fully de activated To fully deactivate the UPS a open the main power switch 1 the reserve line switch 2 the output switch 4 by set ting the lever to the horizontal position 2 18 Installazione Installation UPS 60 120kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 b aprire posizione orizzontale OFF il b open the battery switch 5 by setting the sezionatore batterie 5 lever to the down position C aprire posizione orizzontale c open the BY PASS switch 3 by setting the OFF l interruttore di BY PASS 3 lever it to the down position O 2 5 2 Esecuzione dei collegamenti 2 5 2 Wiring 1 Svit
36. AMETERS STATUS ALARM MENU UPS PARAMETERS INPUT VOLTAGE L1 N L2 N INPUT VOLTAGE L1 L2 L2 L3 OUTPUT VOLTAGE L N INPUT CURRENT l r S OUTPUT CURRENT l out BATTERY Vbatt lbatt Autonomy FREQUENCY Fin Fout TEMPERATURE T C OUTPUT POWER KW kVA UPS SETTING Vout Fout PS 1 4 8 Uso e manutenzione User manual UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 Da lt scelta menu gt possibile selezionare uno From lt menu choice gt itis possible choose nal dei seguenti sottomenu of the following menu MODO COMANDI In questo menu pos COMMAND MODE in this menu it is sibile eseguire comandi operativi sull UPS possible to execute operative commandon UPS MENU STATI ALLARMI STATUS ALARM MENU COMMAND MODE INVERTER ON OFF o INVERTER ON OFF i nn a vuUOU O FP 2 pra lt ON OFF Inverter Start Stop Inverter COMMUTAZIONE CARICO lt lt SWITCH LOAD a lt Commuta il carico sulla Transfer load to bypass linea di bypass BATTERY TEST BATTERY TEST 3 Mi SS E Cc Fr Battery test manuale Battery test manual a Inverter ON OFF il comando di accensione a Inverter ON OFF is the commnad to start and e spegnimento dell Inverter In caso disovracca stop the Inverter In case of overload this rico resetta e permette la riaccensione command reset the alarm condition and restart dell Inverter the inverter b Co
37. CAL HELP Premessa Foreword V di PREMESSA FOREWORD UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 Le lt y PREMESSA FOREWORD NORME DI SICUREZZA Carico sul pavimento del locale di installazione In considerazione dei pesi del sistema UPS Cap 1 5 Caratteristiche neces sario scegliere un locale di installazione il cui pavimento sia in grado di sostenere il peso dell apparecchiatura In caso di pro blemi consultare il costruttore Accesso ai locali Il locale deve presentare uno spazio suffi ciente a garantire i movimenti necessari per l installazione le porte devono avere una dimensione sufficiente a consentire l ingresso dell apparecchiatura Per muo vere l apparecchiatura utilizzarre un transpallet in grado di sostenere il peso dell UPS Dimens dei locali e i inquinamento Deve essere lasciato uno spazio suffi ciente a garantire la corretta esecuzione dei normali interventi di manutenzione Tra il tetto dell UPS e il soffitto dei locali di installazione deve essere presente uno spazio di almeno 400 mm Il locale deve essere sufficientemente pulito e senza polveri carboniose o conduttive grado di inquinamento consentito 2 Ventilazione Latemperatura d esercizio dell UPS com presa tra 0 C e 40 C La temperatura ambiente ideale non dovrebbe superare i 25 C Il calore prodotto dall UPS viene estratto da ventilatori interni e dissipato nell a
38. CE Manuale tecnico ediz 00 Technical handbook Issue 00 60 120KVA Serie SA ATLAS 60 120 kVA Manuale tecnico Technical handbook Edizione 01 ssue 01 Gennaio 2008 January 2003 NOTA CONSERVARE QUESTO MANUALE TECNICO IN UN LUOGO CONOSCIU TO E ACCESSIBILE A TUTTO IL PERSONALE ADDETTO ALL UPS IT ISMANDATORY THIS TECHNICAL HANDBOOK IS HOUSED IN A PLACE KNOWN TO THE PERSONNEL OPERATING ON THE UPS SO THAT THEY CAN FIND AND USE IT ANY MOMENT Premessa Foreword TIPO DI DOCUMENTO Document type Descrizione generale e istruzioni per l installazione l attivazione l uso e la manutenzione General overview instructions for installing and starting up the Ups User manual EDIZIONE Issue rl PRODOTTO Product Gruppo statico di continuit On line a doppia conversione con by pass automatico On line type uninterruptible power supply unit with double conversion and automatic by pass MODELLO Model UPS 60 120 KVA ANNO DI COSTRUZIONE Manufacturing Date 2002 CONFORMITA conformity Marchio CE CE BRAND APPLICAZIONI PER SUPPORTO VITA A causa della variet delle applicazioni e delle normative applicabili in ciascun caso non raccomanda la vendita di questo prodotto per un utilizzo non perfettamente consapevole La responsabilit di applicazioni ove un malfunzionamento o l inadeguatezza dell UPS portino al rischio della vita umana sar a carico del
39. E TECNICO QUALIFICATO Per tutti i collegamenti utilizzare cavi con sezio ne come indicata nella tabella a pag 2 9 Per la sicurezza del personale addetto all installazione assicurarsi che le operazioni di collegamento vengano effettuate nelle se guenti condizioni assenza della tensione primaria di rete utenze disattivate UPS totalmente disattivato Per disattivare totalmente l UPS a aprire gli interruttori di ingresso rete 1 di linea di riserva 2 di uscita 4 b aprire il sezionatore batterie 5 C aprire l interruttore di BY PASS 3 1 Aprirela porta e rimuovere il pannello di protezione inferiore 2 Collegare al collettore di terra il cavo di terra proveniente dal quadro di distribu 2 2 2 Tagblock wiring THE OPERATIONS DESCRIBED IN THE PARAGRAPHS THAT FOLLOW MUST BE CARRIED OUT BY AUTHORIZED ELECTRI CIANS OR BY TECHNICAL PERSONNEL Use section cables as described in page 2 9 As far as the installation personnel s safety is concerned make sure that the wiring operations are carried out under the following conditions primary mains voltage cut off users cut off UPS fully de activated To fully deactivate the UPS a open the main power switch 1 the reserve line switch 2 the output switch 4 by set ting the lever to the down position b open the battery switch 5 by setting the lever to the down position zione principale O c open the BY
40. H N PE GND MORSETTIERA DELL UPS UPS TAGBLOCK wipe ASSE ane Ei f alla spats sl t ig T dl O HEE i W1 cig N1 1 Ingresso rete fase U1 Output phase U2 na 2 Ingresso rete fase V1 Output phase V2 3 Ingresso rete fase W1 Output phase W2 4 Ingresso neutro Output neutral Sezione Section6 mm 5 Ingresso riserva U1 Input reserve U1 6 Ingresso riserva V1 Input reserve V1 PE terra gn ia ooo PE OVOUNG E and 9 Positivo batt Battery positive 10 Negativo batt Battery negative 11 Uscita fase U2 Output phase U2 12 Uscita fase V2 Output phase V2 13 Uscita fase W2 Output phase W2 14 Uscita neutro Output neutral 15 Massa GND Ground GND Fig 2 8 Allacciamento provvisorio per la ricarica delle batterie Temporary connection to enable battery recharge 2 20 Installazione Installation UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 3 ATTIVAZIONE Indice 3 1 Prima accensione e verifiche 2 3 1 1 Istruzioni per la prima accensione dell UPS neern sia 2 3 1 2 Verifica dello stato dell UPS sull pannello frontale e delle N 3 SETUP Table of contents 3 1 Initial turn on and checks 2 3 1 1 UPS Initial turn on INSIMCIONS ica 2 3 1 2 Check on the UPS status of the front panel and segnalazioni 3 Signalling sitesuisima
41. L BY PASS 14 4 3 4 Interruttore UPS OUTPUT 14 4 3 5 Sezionatore fusibili BATTERY 15 4 4 Istruzioni per l uso 15 4 4 1 Accensione dell UPS 15 4 4 2 Spegnimento dell UPS 16 4 4 3 Inserimento del By pass manuale e spegnimento dell UPS senza interruzione di alimentazione al carico 17 4 USER MANUAL Table of contents 4 1 General overview 3 4 1 1 ODeralolizal iaia laica iaia 4 4 1 2 Automatic By pass 4 4 1 3 Manual By pass 4 4 2 Front panel ssssoosnsnnonnnnnnnnnnnnnnnnnnnn D 4 2 1 MENU push button 5 4 2 2 ESC push button 5 4 2 3 BACK and NEXT push button 6 4 2 4 NORMAL light 7 4 2 5 ALARM light 7 4 2 6 Control panel menu 7 4 3 Front distribution panel 14 4 3 1 INPUT MAINS switch 14 4 3 2 RESERVE INPUT switch 14 4 3 3 MANUAL BY PASS switch 14 4 3 4 UPS OUTPUT Switch 14 4 3 5 BATTERY fuses switch 15 4 4 User s guide 15 4 4 1 UPS switching ON 15 4 4 2 UPS switching off
42. ON OFF using the arrows lt 3 or gt 4 and press ENTER pushbuttons 3 and 4 together to confirm The general ALARM will be activated 5 check the status Load on bypass on LCD Inserzione del By pass manuale Manual By pass insertion fig 4 3 Al termine della manovra le utenze continuano ad essere alimentate dalla rete At the end of the operation the users will continue receiving power from mains co su by pass 6 rimuovere Il fermo meccanico sull interruttore MANUAL BY PASS e chiudere l interruttore verr visualizzato l allarme MANUAL BYPASS ON aprire l interruttore OUTPUT aprirel interruttore INPUT MAINS aprire l interruttore INPUT RESERVE 0 aprire il sezionatore BATTERY CN Verificare che il carico continui ad essere alimentato dalla rete con l UPS spento 3 2 PREDISPOSIZIONI Le sole predisposizioni necessarie sono quelle relative alle interfacce di collegamento ai dispo sitivi esterni quali personal computer pulsante di spegnimento di emergenza pannello remoto display 6 remove the mechanical lock from the MANUAL BY PASS switch and liftthe switch lever MANUAL BY PASS ON alarm will be displayed 7 open the OUTPUT switch lever 8 oper the INPUT MAINS switch lever 9 open the INPUT RESERVE switch lever 10 open the BATTERY switch lever Ascertain that the load continues to be pow ered from mains while the UPS is switched off 3
43. ONE BATTERIA OK La tensione di batteria nei limiti specificati Il carico alimentato CARICO SU INVERTER dall Inverter in continuit Il carico alimentato dalla linea di riserva non in continuit Questa pu essere una condi zione temporanea 20sec se nessun altro allarme s pre sente CARICO SU RISERVA USO E MANUTENZIONE USER MANUAL 4 24 Uso e manutenzione User manual UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 4 9 UPS STATUS normal mode STATUS INVERTER OPERATING MAINS WITHIN LIMITS BYPASS LINE WITHIN LIMITS INEVERTER BYPASS SINCRONIZED BATTERY VOLTAGE WITHIN LIMITS LOAD ON INVERTER LOAD ON BYPASS INTERPRETATION The inverter is turned on and it is normally running The input mains is present and the voltage is in specified range The input bypass line is present and the voltage is in specified range Indication of regular syncronism state between inverter and bypass The battery voltage is in specified limits Load is supplied from the Inverter Load is supplied from the Bypass line This can be a temporarycondition for 20sec if no alarm present di USO E MANUTENZIONE USER MANUAL Uso e manutenzione User manual 4 25 piro RISOLUZIONE DEI PROBLEMI USO E MANUTENZIONE USER MANUAL ALLARME INVERTER SPENTO SOVRACCARICO INVERTER BATTERIA NON INSERITA FINE SCARICA BATTERIA PREALLARME BATTERIA
44. PASS switch 3 by setting the lever it to the down position 1 Open the door and remove the lower protection panel 2 Connect the ground lead incoming from the main distribution panel to the GND busbar of the cubicle 2 10 Installazione Installation norms adopted for the UPS 60 120kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 3 Collegare il cavo di terra per l alimenta zione delle utenze alla barra di terra dell UPS 4 Collegare i cavi della rete di ingresso ai terminali del sezionatore 11 come indi cato nella figura 5 Collegare i cavi di alimentazione per le utenze ai terminali del sezionatore 14 6 Collegare i cavi della rete di riserva ai terminali del sezionatore 13 7 Collegare i cavi dell armadio batterie ai terminali dei fusibili sezionabili 3 Connect ground for utilities to the UPS GND busbar 4 Connect mains cables to isolator 1terminal blocks as indicated on figure 5 Connect load cables to isolator 14 terminal blocks 6 Connect reserve mains cables to isolator 3 terminal bloks 7 Connect cables from battery cubicle to isolating fuses terminals La sezione raccomandata dei fili descritta nella ta bella a pag 2 9 Le norme di riferimento per la dimensione dei cavi sono VDE 0100 parte 3 e UNEL 35024170 _ Use section cables as described in the table of pag 2 9 The reference dimensions of the cables ar
45. PS do not wear clothes that can create static charges Technical support This equioment must be serviced by quali fied personnel Personnel Info All the personnel operating on the UPS specialized or not have to be acquainted with all these Safety Instruction VIII Premessa Foreword UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 A 3 a LJ y ISTRUZIONI DI SICUREZZA Prima di fare l installazione Aprire gli interruttori INPUT MAINS INPUT RESERVE MANUALBY PASSeOUTPUT tutte le levette devono essere orizzontali per isolare completamente l apparecchia tura l alimentazione di ingresso e l even tuale batteria esterna devono essere iso late dall UPS Togliere i fusibili dell armadio batterie esterno e o aprire il sezionatore di batteria Installazione L installazione di questa apparecchiatura deve essere eseguite da personale quali ficato secondo le informazioni date nel Cap 2 Installazione Alta corrente di dispersione verso terra Prima di collegare i cavi di alimentazione collegare la protezione di terra Protezione differenziale Questo dispositivo ha un alta corrente di dispersione verso la terra di protezione La corrente massima di dispersione a terra di 300mA Nel tarare la soglia dell interrut tore di dispersione a terra installato a mon te di questa apparecchiatura tenere pre sente questo contributo di corrente e quel lo dovuto ai carichi
46. S stored energy mode Spia rossa LOW BATTERY accesa pre allarme di 3 Red LOW BATTERY light glowing to indicate the batteria prealarm status Spia gialla ON BYPASS accesa carico dalla linea di 4 Yellow ON BYPASS light to indicates that the riserva load is automatically by passed powered Pulsante di silenziamento dell allarme acustico 5 Buzzer silent push button Spia verde POWER ON accesa presenza 6 Greeen POWER ON light glowing indicatethe dell alimentazione del pannello sinottico correct power supply of the remote monitor USO E MANUTENZIONE USER MANUAL Uso e manutenzione User manual 4 21 USO E MANUTENZIONE USER MANUAL UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 4 7 MANUTENZIONE ORDINARIA AVVERTENZA le prove prescritte nel seguito possono causare la perdita di dati dei PC alimen tati dall UPS Si consiglia di effettuare tali prove in condizioni di sicurezza p es utilizzando carichi non critici o evitando manovre che comportino perdite di dati nel sistema 4 7 1 Verifica dell intervento dell UPS Una volta al mese staccare la rete di ingresso all UPS aprire l interruttore INPUT MAINS e verificare che il carico continui ad essere alimen tato regolarmente solo dall UPS aprire l interruttore INPUT MAINS si accen dono le seguenti spie spia rossa 6 allarme generico con allar me acustico silenziabile Premere il tasto Premere 2 per s
47. VIII Strip metal objects VIII Non fumare VIII Do not smoke VIII Assistenza sala VIII Technical support VIII Informazione del personale VIII Personnel info VIII A 3 Istruzioni di sicurezza IX A 3 Safety instruction IX Prima di fare l installazione IX Before starting installation IX Installazione o IX WASTQNQUON lana IX U T PTX 10 01 2003 Descrizione Data Controllato Realizzato Data ooo Premessa Foreword ill PREMESSA FOREWORD UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 Collegamento di terra IX Earn CONECO ene IX Protezione differenziale IX Earth leakage protection IX IN caso di incendio IX In CaSe Ol MO ila IX Addestramento del personale IX Personnel training IX A 4 Demolizione e smaltimento x A 4 Dismantling and disposal X Smaltimento dell imballaggio X Disposal Of packing X Smaltimento delle parti metalliche X Disposal of metal parts X Smaltimento delle schede elet
48. al basso Grado di protezione IP20 Sistema 60kVA 80kVA 100kVA 120kVA Configurazione On line doppia conversione Tensione nominale ingresso 3ph N 380 415 Vac Variazione tensione ingresso 300 480 Vac 330 480Vac a pieno carico Frequenza nominale ingresso 90 60HZz Variazione di frequenza ammessa 40 0Hz CorrenteMax assorbita con tensione di 400Vac 107A 137A 166A 200A Tensione nominale uscita 380 400 415Vac regolabile Frequenza nominale uscita 50 60 Hz Distorsione armonica totale THD econ carico lineare lt 3 econ carico distorcente secondo EN50091 3 lt 7 Stabilita della tensione di uscita 1 Stabilita della frequenza con sincronismo di rete 1 4 selezionabile econ oscillatore proprio 0 005 Potenza uscita nominale 60kVA SOKVA 100kVA 120kVA Potenza attiva 48kW 64kW 80kW 100kW rendimento eal 50 carico gt 91 gt 92 gt 92 gt 92 5 eal 100 carico gt 92 gt 92 5 gt 93 gt 93 8 Perdite massime con carico nominale e batteria carica 4 2kW 5 2kW 6 02kW 6 6kW 3612kcal h 4472kcal h 5177kcal h 5685kcal h Sovraccaricabilit Inverter 125 per 10 minuti 150 per 10 secondi Commutatore Statico 150 30 minuti 1000 100ms Variazione ammessa sull uscita inverter per commutazione su bypass 15 La SHT POWER si riserva i diritti di modificare i dati del presente documento senza alcun preavviso Pag 4 11 Documento DT0340 Rev 02 21 01 2003 Specifica Tecnica ATLAS 60 120 kVA Sistema 60kVA 80kVA 100kVA 120kVA
49. al pannello dell UPS deve nel software scegliere Basic Comm xxKva xxmin Ovviamente i numeri qui non scritti devo corrispondere alle caratteristiche del vostro UPS 3 2 2 PC Interaction setting option As explained before in this manual UPS can broadcast its status and its working measures This communication can be of two levels ad vanced serial or basic serial In dependance of which you prefer and therefore of how you set both hardwere and firmware of the UPS during the software installation you need to choose the correct item from UPS model list When UPS first leaves the factory it s setup for using the reachest communication and this makes you to choose SQP3 8ph as UPS model In case the customer wpuld prefer using the basic coominication for special needs while installing the UPSMAN software he has to choose Basic Comm xxkVA xxmin where xx are values in accordance with the model in your possession ursan O OOOO O x Device Model Type No UPS model defined F Open oe Basic Comm 40kV A 20min Location Basic Comm 40kVA 2Emin Basic Comm 40kV A 30min _ Basic Comm 40kVA 45min Sta E asic Comm 40k A EOmin Basic Comm 40k 4 64min Load VA Smart Communication UPS Single Phase UPS Date of Batel 31 7AKGP via fibre ontie 23 05 2002 Device Comport comi Baudrate 2400 UFS ID o Listen Port 5769 Licencekey BODE Max 445544 HTTP Fort o Restore Factory Settings 1995 2001 Generex G
50. anual 4 7 USO E MANUTENZIONE USER MANUAL USO E MANUTENZIONE USER MANUAL UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 mostra lt scelta menu gt e usando tasti NEXT e BACK possibile scegliere il menu desiderato Premendo contemporaneamente i pulsanti NEXT e BACK si esegue il comando ENTER e si seleziona il livello pi basso del menu scelto La scritta confermato sul display e un beep sonoro indicheranno l avvenuta azione Premendo il tasto ESC si ritorner al livello precedente Dal menu STATI ALLARMI UPS premendo il tasto NEXT si accede al menu PARAMETRI MENU STATI ALLARMI PARAMETRI UPS TENSIONE INGRESSO L N L1 N L2 N L3 N TENSIONE INGRESSO L L L1 L2 L2 L3 L3 L1 TENSIONE USCITA L N COTTENTE INGRESSO l r S l t CORRENTE USCITA l out BATTERIA Vbatt lbatt Autonomia FREQUENZA Fin Fout TEMPERATURA T CT POTENZA USCITA KW KVA CONFIGURAZIONE UPS Vout Fout PS 1 lt menu choice gt and using NEXT and BACK pushbuttons it is possible to choose the desired menu Pressing NEXT and BACK pushbutton at the same time the ENTER command is selected and the lower level willbe reached The confirmed on the display and a beep will indica te the action occurred Pressing ESC pushbutton it is possible to go back at the previous level From STATUS ALARM MENU pressing NEXT it possible to access at UPS PAR
51. apsacnassoveaadercarianberdvedussaes 3 3 1 3 Prova di inserimento del carico 3 3 1 3 LOA insertion test 3 3 1 4 Prova di intervento dell UPS 4 3 1 4 UPS intervention test 4 3 1 5 Prova dello stato di carica della 3 1 5 Test on the battery charge batteria i 4 CONDONO na 4 3 1 6 Prova di commutazione su linea di 3 1 6 Test on switching over to the reserve line riserva By pass automatico 5 automatic by passS SA 3 1 7 Verifica del funzionamento del 3 1 7 Manual By pass By pass manuale n 5 operation Check 5 T 3 2 Predisposizioni disp opzionali 6 3 2 Settingoptions 6 Y I 3 2 1 Predisposizioni sulla scheda rele 7 3 2 1 Setting options on the Relay card 7 LU 3 2 2 Predisposizioni per la comunicazione 3 2 2 PC Interaction setting 8 Z OMI Te CG ine 8 O 3 3 Attivazione dei dispositivi 3 3 Pheripheral device set up 9 DETIIGMICN siirinsesi 9 gt 3 3 1 Verifica del circuito di spegnimento 3 3 1 Check of the Emergency Power Off forzato in emergenza E P O 9 611501028 405 RE eee ne nee reer ee 9 3 3 2 Prova del pannello remoto 10 3 3 2 Remote panel test 10 amp f 3 3 3 Verifica delle
52. ard optional can be mounted on UPS hence connecting it both to the remote panel and to the PC The card cannot be fitted with an additional EPO button To connect several EPO buttons to UPS first connect them in series and then connect the lot to one of the CN3s available scheda Rele Rel card pulsante E P O E P O pushbutton N C N C Normalmente Chiuso Normally Closed Fig 2 5 Collegamento del pulsante E P O E P O connection 2 14 Installazione nstallation UPS 60 120kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 2 3 2 Collegamento con il Personal Computer L interfaccia segnali che equipaggia l UPS consente di monitorare lo stato dell UPS con il Personal Computer Qualora si verificassero anomalie esse verranno visualizzate in modo dettagliato sul PC Per la realizzazione di questo collegament utilizzare l apposito cavo fornito a corredo del software Generex Il software e il relativo corre do sono forniti in opzione su richiesta 1 Collegarel estremoconconnettore maschio al corrispondente connettore DB9 femmina sull UPSel altro estremo ad una porta seriale del PC come di seguito illustrato connettore DB9femmina alla porta seriale del PC 2 3 2 Connection to Personal Compu ter The signals interface equipping UPS moni tors the state of UPS with the Personal Compu ter Any failures present will b
53. are completamente le quattro viti del 1 Fully unscrew the four screws from the pro pannello di protezione della morsettiera tection panel situated on the UPS tagblock dell UPS 2 Collegare alla barra di terra 15 dell UPS il 2 Connect the ground lead to the PE bar of cavo di terra fig 2 8 the UPS Fig 2 8 Per il collegamento della messa a terra To ground connect use a 6 sq mm section utilizzare un cavo con sezione di almeno 6 cable mm 3 Collegare il cavo della tensione di rete fig 3 Connect the mains voltage lead see Fig 2 8 ai seguenti morsetti dell UPS 2 8 to the following UPS terminals 1 fase U1 1 phase U1 2 fase VI 2 phase V1 3 fase W1 3 phase W1 4 neutro N1 4 neutral N1 INSTALLAZIONE INSTALLATION Per il collegamento della tensione di rete With regard to mains voltage connection use a 6 utilizzare conduttori con sezione di almeno sg mm section cable 6 mm Ultimati i collegamenti avviare la carica delle After having completed the wiring connec batterie attenendosi a quanto descritto nel capi tions charge the batteries as instructed in the tolo USO E MANUTENZIONE USER MANUAL chapter Installazione nstallation 2 19 Z I gt x ml LLI lt O N lt al a H Y Z UPS 60 120kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 rete 380 415 Vca 50 Hz 3F N PE GND mains 3802415 Vac 50 Hz 3P
54. are l UPS a un pannello remoto per le segnalazioni dello stato 2 3 1 Collegamento del pulsante per lo spegnimento forzato E P O 1 Munirsi di un cavo bipolare sezione dei conduttori 0 6 mm di lunghezza opportu na non superiore a 100 m 2 Intestare un estremo del cavo ai morsetti N C di un pulsante antincendio fig 2 5 3 Collegare gli estremi opposti dei cavi alla scdeda Rel fig 2 5 NOTA possibile dotare l UPS di un altra scheda Rel opzionale e collegarlo cos sia al pannello remoto che al PC Non possibile collegare a tale scheda un secondo pulsante EPO Per collegare all UPS pi pulsanti EPO necessario porli in serie tra loro e poi collegare la serie a uno dei CN8 disponibili NECTION A Relay card is situated on UPS rear panel Through this card UPS is connected to a pushbutton whose function is of forcing UPS OFF should an emergency condition arise E P O Emergency Power Off Through plug DB9 the card can establish con nection with UPS to a Personal Computer Throught tag block on it is possible to connect UPS to a remote panel for UPS status indica tions 2 3 1 Emergency Power Off E P O push button connection 1 Geta suitably long not more than 100 m two pole cable 0 6sq mm conductor sec tion 2 Terminate one end of the cable to the N C pins of a fire preventing button Fig 2 5 3 connect the other end of the cable to Relay card Fig 2 5 NOTE Another Rel c
55. arme Si rimanda al capitolo 4 Uso e manutenzione per unadettagliata descrizione del Pannello frontale 1 3 4 Batteries The power delivered by the batteries reaches the input of the step up converter situated on the power module The batteries are continuously recharged by the battery charger module when the mains is present 1 3 5 Relay card The functions carried out by the relay card are as those of the standard card except that with respect to the latter it is provided with a cold contact tagblock which repeats the same sig nals of the DB9 plug Therefore the Relay card drives not only a PC Remote Panel but also any other type of device e g acoustic alarms lamps remote Indications etc 1 The card cannot be connected with an extra EPO button If the UPS has to be forced OFF through several EPO buttons then these should be series connected and afterwards connected to the input port of one of the CN3 plugs 1 3 6 Manual by pass The manual by pass circuit is utilized in those circumstances whereby it is necessary to ex clude UPS while still keep load powered from mains e g Ups not running failure etc This circuit can be operated through the MANUAL BY PASS switch located on the rear plane of UPS The switch which is normally open with the lever set to the orizontal position is provided with a protection stopper to prevent it from being accidentally operated The stopper can also be pad locked to
56. ble Power Supply unit dangerous voltage is present even if all the switches are off For this reason In case of a fire do not use water to put out a fire Personnel training All personnel operating on the UPS have to be trained to perform the Emergency Power Off see A 1 First Aids Premessa Foreword IX di PREMESSA FOREWORD PREMESSA FOREWORD UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 I A 4 DEMOLIZIONE ESMALTIMENTO In caso di demolizione dell UPS le parti di cui composto devono essere affidate a ditte specializzate nello smaltimento e riciclaggio dei rifiuti industriali e in particolare Smaltimento dell imballaggio L imballaggio costituito da materiale biodegra dabile e pu essere consegnato a normali aziende di recupero della cellulosa profili protettivi in poliuretano espanso sono chimicamente inerti e possono essere smaltiti in discariche dove non contribuiscono n alla for mazione di gas n all inquinamento delle acque di infiltrazione Smaltimento delle parti metalliche Le parti metalliche del mobile sia quelle vernicia te sia quelle in acciaio sono normalmente recuperabili dalle aziende specializzate del set tore di rottamazione dei metalli Smaltimento delle schede elettroniche Le schede elettroniche devono obbligatoriamen te essere smaltite da aziende specializzate nello smaltimento di componenti elettronici Smaltimento delle
57. book DT0342 Issue 00 Attendere 20 secondi e verificare il cambiamen to della segnalazione da CARICO SU RISER VA a CARICO SU INVERTER Il carico ora di nuovo alimentato dall UPS Rimettere il fermo meccanico e l eventuale luc chetto all interruttore MANUAL BY PASS 4 4 5 Inserimento del By pass manuale in caso di avaria dell UPS Nel caso in cui occorra escludere l UPS in ava ria attivare il By pass manuale con la seguente procedura 1 accertarsi sullo stato degli allarmi INVERTER SPENTO CARICO SU RISERVA 2 togliere il fermo meccanico con l eventuale lucchetto che blocca l interruttore MANUAL BY PASS chiudere l interruttore MANUAL BY PASS e verificare la visualizzazione dell allar me BYPASS MANUALE INSERITO 3 aprire l interruttore OUTPUT 4 aprire il sezionatore esterno di batteria 5 aprire l interruttore INPUT RESERVE 6 aprire l interruttore INPUT MAINS In caso fosse necessario staccare l UPS dall im pianto es per riparazione il mantenimento dell alimentazione al carico possibile solo se l impianto dotato di By pass esterno Sequenza di inserimento del By pass manuale in caso di avaria dell UPS Sequence to follow to connect the manual by pass switch should UPS fail Wait for20 seconds and check that the aron status from LOAD ON BYPASS to LOAD ON INVERTER The load is once again powered from UPS Place the mechanical lock and eventually the pad lock too ba
58. by an air condition ing system Allowed use The unit must be used as intended Follow the instructions given in Chapt 4 User s Manual VI Premessa Foreword UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 LJ Neel ait Surriscaldamento Per impedire il surriscaldamento non ostruire il flusso dell aria dalle apposite aperture dell unit NON appoggiare oggetti sul tetto Precauzioni elettriche All interno dell unit sono presenti tensioni pericolose Non aprire l unit e gli armadi ausiliari componenti all interno dell unit non pos sono essere riparati dall utente NON devono inoltre essere rimossi i co perchi protettivi dall interno dell armadio UPS Tutti gli interruttori generali installati a monte dell UPS devono recare la seguen te dicitura Isolare l UPS Gruppo di conti nuit prima di lavorare su questo circuito Arresto in emergenza L unit munita di E P O Emergency Power Off arresto di emergenza Que sta funzione viene attivata premendo il pulsante di emergenza esterno al quale stata collegata Essa prevedel estinzione della tensionesul carico e l arresto dell inverter Saranno ancora presenti ten sioni pericolose all interno dell unit con densatori carichi aspettare 5 minuti prima di agire sull unit Batterie Durante l elettrolisi le batterie rilasciano gas idrogeno Esiste il rischio di esplosio ne se la qua
59. causare danni notevoli Non fumare Operando sull UPS NON FUMARE o non usare fiamme libere ed evitare di creare archi lavorando sull UPS non vestire abiti che possono generare elettricit statica Assistenza L assistenza su questa apparecchiatura deve essere eseguite da personale quali ficato Informazione del personale A tutto il personale che si accinge ad operare sull UPS sia esso specializzato o meno deve essere fatta prtendere visione delle presenti Norme e Istruzioni The installed battery when in good condi tion looks dry and no corrosive liquid drops out its case In case of accidental crash inspect accu rately the batteries A broken case can the electrolyte drops out the latter can cause burns of the skin corrode metal cabinet finishing coating andfabricsorcause short circuiting among the internal parts and the electrolyte Protective gloves When handling damages batteries it is mandatory to wear protective gloves Isolating carpet While working on the UPS stand on a rubber carpet and use isolated tools only Strip metal objects While working on the UPS strip all per sonal objects ring watch steel pen etc which can cause short circuiting when working on batteries The batteries are always on and if short circuited they can fuse metals and cause many damages Do not smoke While working on the UPS DO NOT SMOKE do not use flames avoid to cre ate electric arcs when working on the U
60. cause for switching clears the auto matic switching circuit automatically cuts off and the load is once again powered through UPS The intervention ofthe automatic by pass switch is signalled on the front panel through the turning on of the yellow light 4 1 3 Manual By pass The manual by pass circuit is utilized in allthose circumstances whereby UPS must be excluded while still keeping the load powered e g UPS not running failure etc This circuit can be operated through the MANUAL BY PASS switch situated on UPS front opening the door The switch is provided with a mechanical lock protecting it against accidental operations The mechanical lock can be further secured with a padlock This latter measure is used to prevent unauthorized personnel from removing it 4 4 Uso e manutenzione User manual UPS 60 120kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 di 4 2 IL PANNELLO FRONTALE L intero funzionamento del gruppo viene gestito attraverso il pannello frontale dell UPS I comandi disponibili sono estremamente semplici e all insorgere di una condizione d allar me viene segnalata dall UPS attraverso l attiva zione di un avvisatore acustico d allarme l ac censione di una spia rossa di allarme generico e la visualizzazione sull LCD del tipo di allarme 4 2 1 Pulsante MENU Il pulsante MENU 1 ha la funzione principale di far accedere ai vari men dell UPS Modo Comand
61. cheda caricabatteria in grado di ricaricare le batterie all 80 della capacit massima entro12 ore L interfaccia segnalazioni preleva le segnalazioni dalla Logica di controllo e le converte nel protocollo previsto peril pannello frontale dell UPS e perlascheda Rel A ritroso i criteri provenienti dal pannello frontale forzatura by pass automatico e o dalla scheda Rel EPO vengono inviati dall interfaccia segnalazioni alla Logica di controllo che lo interpreta rispettivamente commutando sulla lineadi riserva e o spegnendo immediatamente l UPS L interfaccia segnalazioni pu alimentare oltre alla scheda Rel standard anche un altra scheda opzionale una seconda scheda rel L alimentatore ausiliario provvede ad alimentare la Logica di controllo il pannello frontale e le schede rel is still powered from mains When the cause that had produced switch over clears the by pass will automatically revert to inverter powering The 400 Vac filtered regenerated and stabilized mains voltage is delivered through the UPS OUTPUT switch to the load 1 3 3 Logic and Auxiliary circuits The control logic resides on a specific card and represents the smart section of UPS In fact it manages the operating mode of the step up converter of the inverter and of the by pass by feed back comparing the signals extracted from the power module The control logic also manages three other cards i e the battery charger the auxiliar
62. ck onto the MANUAL BY PASS switch 4 4 5 Manual by pass connection follow ing UPS failure When having to exclude the faulty UPS activate the manualby pass switch in the following order 1 be sure on the status of alarms INVERTER OFF LOAD ON BYPASS 2 remove the mechanical lock and eventually the pad lock too blocking the MANUAL BY PASS switch and lift the lever of MANUAL BY PASS and check the ALARM MANUAL BYPASS ON 3 open the OUTPUT switch 4 open the external battery isolator 5 open the INPUT RESERVE switch 6 open the INPUT MAINS switch Should it be necessary to cut off UPS from the plant e g for repair reasons the load will conti nue to be powered only ifprovided with an external By pass Uso e manutenzione User manual 4 19 USO E MANUTENZIONE USER MANUAL USO E MANUTENZIONE USER MANUAL UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 4 5 USO CON IL PC Collegato a un Personal Computer o a una rete di PC l UPS gestibile tramite Windows NT La gestione tramite il software UPS Management opzionale permette lo spegnimento automati co del PC locale e remoto della rete il monitoraggio delle principali funzioni dell UPS il protocollo SNMP ecc Una descrizione completa di funzioni e modalit d uso inclusa nel pacchetto software UPS Management 4 5 USE WITH THE PC If connected to a Personal Computer o
63. cy push buttons not sup plied can be connected These in case of fire fully de activate the UPS Since UPS operates in an automatic mode there is no need to forward commands Therefore the front panel is extremely easy and operation is the sole function to have a periodical check UPS is easily managed through a personal com puter and through an interacting program op tional A remote panel optional can be connected to UPS for remote control operations The remote panel is considered essential when the UPS is installed in unmanned rooms it displays the operating mode repeats the alarms through the lighting up of LEDs and activates a buzzer 1 1 4 Construction details The control panel is placed on the front door Behind the door in the lower part of the cubille VOpowerswitches terminals are also VO connectors for over power cables Power cables inlet is provided from the top or from the bottom of the cubicle Informazioni generali General overview 1 3 A INFORMAZIONI GENERALI GENERAL OVERVIEW UPS 60 120kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 N 1 2 CONFIGURAZIONI E 1 2 CONFIGURATION AND EQUIPAGGIAMENTI OPTIONAL EQUIPMENT OPZIONALI 1 2 1 Configurazioni base 1 2 1 Base configuration Configurazione base Base configuration La configurazione base prevde l UPS trafoless The base configuration provides trafoless nel propr
64. da 87 Quadro elettrico dell UPS 3 at Jk 8 a t seguitovienedatala disposizione degli inter ruttori e relative connessioni 2 1 6 Siting itin the operative position The UPS is fitted with wheels so as to easily move itto the right place The place chosen must guarantee easy connection enough space to easily work on UPS con sidering also troubleshooting and corrective maintenance operations interchange of air sufficient enough to dispel heat produced by UPS protection against atmospheric agents protection against excessive humidity and very high heat sources protection against dust compliance with the current fire prevention norms operative environment temperature within 20 C and 25 C The batteries are at maximum efficiency in this temperature range 2 1 7 UPS distribution panel The following figure illustrates the switches and plugs arranged on UPS Installazione Installation 2 7 INSTALLAZIONE INSTALLATION UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 2 2 ALLACCIAMENTO DELL UPS 2 2 UPS CONNECTION TO THE INSTALLAZIONE INSTALLATION ALLA RETE Per garantire il corretto funzionamento dell UPS e dei suoi eventuali equipaggiamenti opzionali necessario approntare opportuna mente la rete elettrica sia a monte che a valle dell apparecchiatura dotandola di appositi dispositivi di protezione I collegament
65. dere ilsezionatore RESERVE INPUT 13 2 chiudere il sezionatore UPS OUTPUT 14 attendere l avvio del ventilatore e quindi presenza della tensione in uscita 3 chiudere il sezionatore MAINS INPUT 11 4 chiudere il sezionatore BATTERY 5 premere il pulsante 1 MENU 6 Selezionare il menu COMANDI con le frecce lt 3 o gt 4 e premere ENTER tasti 3 e 4 contemporanea_ mente per conferma 7 Selezionare INVERTER ON OFF con le frecce lt 3 o gt 4 e premere ENTER tasti 3 e 4 contemporanea_ mente per conferma 8 Premere CLEAR per uscire dal menu COMANDI e posizionarsi sul menu segnalazioni e allarmi ATTIVAZIONE SETUP Sequenza di accensione Switching ON sequence 2 close the UPS OUTPUT switch 14 8 Press CLEAR pushbutton to exit from COMMAND MODE menu to visualize the status and alarm menu 1 close the RESERVE INPUT switch 13 wait the fan run so the voltage is present to the output 3 close the MAINS INPUT switch 11 4 close the battery isolator 5 press the MENU pushbutton 1 6 Choose the COMMAND MODE menu using the arrows lt 3 or gt 4 and press ENTER pushbuttons 3 and 4 togheter to confirm 7 Choose INVERTER ON OFF using the arrows lt 3 or gt 4 and press ENTER pushbuttons 3 and 4 togheter to confirm 3 2 Attivazione Setup UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ed
66. dern structure It consists of a galvanized steel iron supporting structure mounted on wheels so as to easily move it around in the room The Supporting structure is covered with a varnished steel shell 1 1 1 UPS type of application The latest UPS is an uninterruptible assembly designed to deliver stabilized and filtered power to sophisticated electronic equipment data processing systems Since the latter are nor mally utilized in medical centers police stations motorway tunnels broadcasting stations banks technical and administrative offices and other applications they must guarantee a power source free from voltage and frequency variations 1 1 2 Power and autonomy The modular design of UPS allows to supply it in versions featuring a nominal power from 60kVA to 120kVA all with cos 0 8 Allversionas have not battery inside an external battery cubicle has to be provided for each autonomy 1 1 3 Safety and ease of use All the controls available are perfectly isolated and decoupled from the high working voltages likewise for the outer parts of the container which have been carefully isolated and galvanically separated 1 2 Informazioni generali General overview UPS 60 120kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 Controlli sia sul sovraccarico che sulla sovra temperatura garantiscono l immediato e piu op portuno intervento nel caso che una di quest
67. diz 00 Technical handbook DT0342 Issue 00 4 1 1 Funzionamento L UPS ha due modi tipici di funzionamento da RETE in presenza della rete le utenze carico sono mantenute alimentate dalla rete stessa filtrata e raddrizzata dall UPS la batteria a riposo e costantemente sotto carica Questa la normale condizione di funzionamento da BATTERIA in assenza della rete la bat teria fornisce l energia necessaria all alimenta zione delle utenze garantendo in tal modo l ali mentazione al carico collegato La commutazione RETE BATTERIA avviene automaticamente e istantaneamente al manca re della rete in maniera altrettanto automatica al ritorno della rete avviene il ritorno alla normale condizione di funzionamento 4 1 2 Linea di riserva By pass automa tico Quando l UPS rileva condizioni anomale es avaria della batteria dei circuiti interni oppure in caso di temperatura eccessiva un circuito detto By pass automatico interviene automaticamen te inserendo una linea di riserva sulla quale la rete continua ad alimentare il carico per tutto il tempo di intervento del By pass automatico Alla scomparsa delle cause che hanno provoca to l intervento del By pass automatico questo viene disinserito automaticamente e il carico viene di nuovo alimentato dall UPS L intervento del By pass automatico segnalato da una spia gialla presente sul pannello frontale 4 1 3 By pass manuale Il By pass manuale un circuito prev
68. e VDE 0100 part 3 and UNEL 35024170 Ingresso rete Mains input massa Ground filo di terra verso le utenze Ground lead towards users ngresso rete fase U1 Output phase U2 ngresso rete fase V1 Output phase V2 ngresso rete fase W1Output phase W2 1 2 3 4 5 6 7 U1 V1 W1 N1 U3 V3 W3 N3 ITTTITTTT as ingresso linea di riserva reserve input 9 Positivo batt 10 Negativo batt MORSETTIERA DELL UPS UPS TAGBLOCK 8 11 12 13 14 U2 V2 W2 N2 LUL uscita UPS UPS output It ingresso batteria battery input collegare a questo collettore il filo di terra proveniente dalla rete di alimentazione in ingresso all UPS Battery positive Battery negative 11 Uscita fase U2 Output phase U2 ngresso neutro Output neutral ngresso riserva U1 nput reserve U1 ngresso riserva V1 Input reserve V1 ngresso riserva W1 Input reserve W1 Ingresso neutro Output neutral ONOoaRWND 12 Uscita fase V2 Output phase V2 13 Uscita fase W2 Outout phase W2 14 Uscita neutro Output neutral 15 Massa GND Ground GND Onto this terminal connect the ground lead incoming from the UPS input mains power supply Fig 2 3 Collegamenti alla morsettiera dell UPS Wiring on the UPS tagblock Installazione nstallation 2 11 Di INSTALLAZIONE INSTALLATION UPS 60 120kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issu
69. e arrows lt 3 or gt 4 and press ENTER 4 ascertain that the UPS has transfer to BYPASS 5 remove the mechanical lock and eventually the padlock too fromthe MANUAL BY PASS switch and close the MANUAL BY PASS switch check that the red ALARM LED 6 light up 6 open the OUTPUT switch 7 Open external batt isolator and batt fuses 8 open the INPUT RESERVE switch 9 open the INPUT MAINS switch The load is now powered from mains only through manual by pass residing on UPS Uso e manutenzione User manual 4 17 USO E MANUTENZIONE USER MANUAL USO E MANUTENZIONE USER MANUAL UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 4 4 4 Riaccensione dell UPS e disinserimento del By pass manuale sen za interruzione di alimentazione al carico Il ripristino del funzionamento dell UPS dopo l inserimento del By pass manuale avviene con la seguente procedura 1 chiudere l interruttore INPUT RESERVE 2 chiudere l interruttore INPUT MAINS 3 Chiudere il sez esterno di batteria ed i fusibili BATTERY 3 4 attendere l accensione del pannello frontale e quindi la segnalazione CARICO SU RISERVA verificare che il ventilatore riparta a funzionare 5 chiudere l interruttore OUTPUT 5 6 Aprire l interruttore MANUAL BY PASS 6 7 premere il pulsante 1 MENU Sequenza per la riaccensione del UPS e disinserimento del By pass manuale Sequence follo
70. e condizioni si verifichi durante il funzionamento E possibile il collegamento di uno o pi pulsanti di emergenza non forniti che in caso di incen dio permettano di comandare la totale disattiva zione dell UPS Poich il funzionamento dell UPS completa mente automatico non c bisogno di dare co mandi perci il pannello frontale estremamen te semplice e ha la sola funzione di verificare l corretto funzionamento a intervalli periodici Il monitoraggio dell UPS pu essere gestito con la massima semplicit tramite un personal com puter ed un apposito programma di comunica zione opzionale Un pannello remoto opzionale per il controllo a distanza pu essere collegato all UPS il pan nello remoto si rivela indispensabile quando UPS installato in locali non sorvegliati visualizza il modo di funzionamento ripete gli allarmi con l accensione di LED e l attivazione di un allarme sonoro 1 1 4 Particolari costruttivi Sulla parte frontale dell UPS posto il pannello di comando Aprendo la porta nella parte inferiore dell UPS sono collocati i morsetti degli interruttori che sono anche i terminali ingresso e uscita di poten za della macchina L ingresso cavi pu essere realizzato dal basso o dall alto Checks have been made both on overload and on overtemperature to guarantee a prompt and fitting intervention should one of the aforemen tioned conditions arise during operation One or more emergen
71. e periodica del gruppo di continuita da effettuarsi a scadenze prefissate Questa manutenzione e buona cosa che venga eseguita da personale tecnico autorizzato in modo che si possano evitare errate operazioni che possano compro mettere il corretto funzionamento dell UPS e quindi causare danni tion grid cleaning Use a duster to clean the cabinet and the front panel To clean the ventilation grid instead use a brush and a vacuum cleaner WARNING Do not use sponges or cloth moistened with water or other liquids neither on the UPS s cabi net nor on surfaces near it 4 8 PERIODIC MAINTENANCE It is suggest a periodic maintenance to do on planned expiries on the UPS to guarantee a constant and efficent protection of the load To avoid wrong operations and faults it is better that technical personnelorelectricians authorized will do the maintenance Uso e manutenzione User manual 4 23 USO E MANUTENZIONE USER MANUAL UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 pa STATI DELL UPS funzionamento normale STATO SIGNIFICATO INVERTER INSERITO L Inverter acceso e sta fun zionando normalmente RETE PRINCIPALE IDONEA La tensione di alimentazione principale presente e nei limiti stabiliti LINEA DI RISERVA IDONEA Latensione della linea di riserva presente e nei limiti stabiliti SINCRONISMO OK Indicata il regolare sincromismo tra l Inverter e la linea di riserva TENSI
72. e 00 i 2 2 3 Allacciamento delle utenze E consigliato collegare a valle dell UPS un ap posito interruttore magnetotermico quadripolare Curva C vedere fig 2 2 e fig 2 4 LE OPERAZIONI DESCRITTE IN QUESTO PARAGRAFO DEVONO ESSERE ESEGUITE DA ELETTRICISTI AUTORIZZATI O DA PER SONALE TECNICO QUALIFICATO collegamenti devono essere effettuati nelle seguenti condizioni assenza della tensione primaria di rete utenze disattivate UPS totalmente disattivato 2 2 3 User connection Its suggested to connect a four pole Curve C magnetothermic switch at the output of the UPS see Fig 2 2 and Fig 2 4 THE OPERATIONS DESCRIBED IN THE PARAGRAPHS THAT FOLLOW MUST BE CARRIED OUT BY AUTHORIZED ELECTRI CIANS OR BY TECHNICAL PERSONNEL The wiring operations must be carried out under the following conditions primary mains voltage cut off users cut off UPS fully de activated interruttore magnetotermico quadripolare Curva C four pole Curve C magnetothermic switch I magnetotermico differenziale 1 safety magnetothermic 1 R presa A A A utenza 1 La barra presente sotto gli interrut User tori consente l ancoraggio del cavo socket 1 INSTALLAZIONE INSTALLATION all UPS stesso mediante l impiego di fascette fermacavi The bar near the switch blocks can be used to fasten the cable to the UPS through cable clamps ie TE e ni i LI a
73. e fully displayed on the PC To set up this connection use the cable supplied with the Generex software The soft ware together with the relative kit are optionally supplied on Customer demand 1 Connectthe male connector tipped end to the corresponding DB9 female connector on UPS and the other end to a serial port on the PC as shown below connector a Te a a a DIE i p i y n 1 Pi lal P mz L kiet TE CEEE Ci mi LI DI E Li n cl m 1 oe ni oe a a E E mi 2 Eseguire le predisposizioni come descritto nel capitolo Attivazione 4 2 4 DB9 female To the PC serial port 2 Presetas specified at para 4 2 4 in the Set up chapter Installazione nstallation 2 15 INSTALLAZIONE INSTALLATION UPS 60 120kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 2 3 3 Collegamento al Pannello remoto 2 3 3 Remote Panel connection INSTALLAZIONE INSTALLATION Il Pannello segnalazioni remoto corredato di The remote signalling panel is provided with a alimentatore power supply unit Costruire un cavo di collegamento di lun Proceed to assemble a connecting cable up but ghezza idonea non superiore a 100 m come da not longer than 100m as shown in Figure 2 6 schema di figura 2 6 Morsettiera M1 pr TRI UPS REMOTE MONITOR UPS ON O ON BATTERY O LOW BATTERY O
74. eria scarica Battery low represent Ups in off state al PC Pannello remoto to PC Remote panel 1 3 2 Schema funzionale dell UPS doppia conv con by pass comando E P O E P O command UPS functional drawing double conversion by pass 00 ENSS ZPEO1LG YOogpuey e21UY929 00 ZIPS ZrvEO qooiude sjenueyy SVILW VAAOZL 09 SdN UPS 60 120kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 Come gi detto in caso di avaria o di sovraccarico il by pass automatico commuta sulla linea di riserva l alimentazione al carico viene cos mantenuta dalla rete Alla cessazione delle cause che hanno provocato lo scambio sulla linea di riserva il by pass ritorna automaticamente all alimentazione da inverter Tramite l interruttore UPS OUTPUT la rete 400 VCA filtrata rigenerata e stabilizzata viene invia ta al carico 1 3 3 Logica e circuiti ausiliari La logica di controllo risiede su un apposita scheda e rappresenta l intelligenza dell UPS Essa si incarica infatti di gestire il funzionamen to del convertitore step up dell inverter e del by pass in base al confronto in retroazione dei segnali prelevati dal modulo di potenza La logica di controllo gestisce inoltre altre tre sche de cio il caricabatteria l alimentatore ausilia rio e l interfaccia segnalazioni Il caricabatterie alimenta continuamente le bat terie esterne collegate all UPS La s
75. es too high Ensure appropri ate ventilation of the battery room accord ing to the Standard EN50091 1 toprevent the risk of an explosion If the average temperature in the room exceeds 25 the battery lifetime is greatly reduced The lifetime is reduced of 1 2 for 10 temperature raising The ideal tem perature should range from 15 to 25 T Premessa Foreword VII REMESSA FOREWORD A UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 y lt lt fy lt PREMESSA FOREWORD y i to di 10 C La temperatura ambiente ide ale compresa tra i 15 C e i 25 C Le batterie installate se integre si presen tano asciutte e nessun liquido corrosivo esce dal contenitore In caso di urto accidentale ispezionare le batterie Un contenitore rotto pu lasciare uscire l elettrolito che pu causare bruciature sulla pelle e corrodere metalli vernici e tessuti o provocare contatto tra le parti interne e l elettrolito Guanti protettivi Usare guanti di gomma se si opera su batterie danneggiate Tappeto isolante Operando sull UPS stare su un tappeto di gomma e usare soltanto attrezzi isolati Spogliarsi degli oggetti di metallo Operando sull UPS togliersi tutti gli oggetti personali anelli orologi penne ecc che possono causare cortocircuiti durante il lavoro sulle batterie Le batterie sono sem pre attive ed un loro cortocircuito pu fon dere metalli e
76. g 2 1 place the equipment on the floor as in structed on the outer case UP DOWN Remove the cover and the side parts of the wooden crate 2 4 Installazione nstallation UPS 60 120kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 Di a posizionare l UPS correttamente sul pavimento rispettando il verso ALTO BASSO place it properly on the floor observing the UP DOWN indications b Rimuovere la struttura dell imballo i i 7 ge A facendo attenzione Remuve the board carefully INSTALLAZIONE INSTALLATION c eliminare il foglio di protezione in polietilene remove the polyethylene d con un muletto appoggiare l UPS a terra use a forklift truck to place UPS on the floor Fig 2 1 Rimozione dell imballo dell UPS Packing removal from UPS Installazione Installation 2 5 INSTALLAZIONE INSTALLATION UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 Togliere l involucro di cellophane di protezio ne Infilarele forche di un muletto sotto l UPS e dopo averlo sollevato di qualche centimetro indietreggiare e appoggiarlo sul pavimento L UPS dotato di ruote con le quali pu essere spostato senza fatica i consiglia di conservare tutto il materiale d imballaggio potrebbe essere utilizzato qualora fosse necessar
77. guration teleohone number has the function to shift the cursor to the next number position 4 2 2 ESC push button The ESC pushbutton 2 has the function to silent the buzzer and to cancel the operation if not confirmed inside the submenu It has also the function of messages scrolling inside the status and alarm menu Uso e manutenzione User manual 4 5 USO E MANUTENZIONE USER MANUAL USO E MANUTENZIONE USER MANUAL UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 pannello dei comandi Il pannello consente di visualizzare lo stato di funzionamento dell apparecchiatura Legenda dei comandi e indicatori dell UPS ulsante MENU ulsante ESC ulsante BACK ulsante NEXT 4 Funzione ENTER Spia verde NORMAL accesa quando l UPS in condizioni di funzionamento normali Spia rossa ALARM accesa quando l UPS in condizioni di allarme Diplay alfanumerico per la visualizzazione delle funzioni e dei parametri dell UPS HO HH U U U U Ce aIL pop 4 2 3 Pulsanti BACK e NEXT pulsanti Back 3 e Next 4 hanno diverse funzioni Premendo contemporaneamente i tasti si conferma l operazione eseguita funzione ENTER nel menu Eventi Remoti Back scorre gli eventi visualizzando solo data e ora Next visualizza l evento selezionato in data e ora con i relativi stati e allarmi nelmenuLinguaggio Operativo Back
78. i Configurazione UPS Il pulsante MENU 1 all inter Eventi Remoti Linguaggio Operativo no dei singoli men cambia di funzione Orologio nel men Eventi Remoti Visualizza Eventi ha la funzione di visualizzare l ultimo evento registrato nel men Orologio Data oppure Ora permette lo spostamento del cursore alla cifra successiva nel men Configurazione UPS Numero di telefono permette lo spostamento del cursore alla cifra successiva 4 2 2 Pulsante ESC Il pulsante ESC 2 ha la funzione di tacitazione e di annulla operazione se non confermata all interno dei vari men Ha la funzione di scrolling nel men allarmi e stati 4 2 FRONT PANEL The assembly is fully operated through the UPS s front panel The commands available are very simple and ifthe presence ofan alarm state is signalled by the UPS through the activation of a buzzer the turning on of the red general alarm light and showing on LCD the kind of alarm 4 2 1 MENU push button The MENU pushbutton 1 has for main function to access to the submenu of UPS Command mode Event history Operating language Clock UPS configuration Inside the submenu the MENU pushbutton 1 change his function menu Event history Display events has the function to display the last record event menu Clock Date or time has the function to shift the cursor to the next number position menu UPS Confi
79. i General overview UPS 60 120kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 1 3 PRINCIPIO DI FUNZIONAMENTO II UPS un gruppo di continuit del tipo On line a doppia conversione con by pass automatico a norma europea EN50091 1 3 definizione ANIE Ups CIB Tale tipo di UPS effettua in maniera continuativa e senza alcuna interruzione una doppia conversione della tensione in entrata Lamancanzadi collegamento diretto rete carico non consente il passaggio di alcun disturbo e la doppia conversione garantisce in uscita un energia sempre rigenerata sia in tensione che in frequenza ideale per il funzionamento di utenze professionali Quando la tensione d ingresso esce dalle tolleranze ammesse il carico viene alimentato prelevando energia dalle batterie L Utente dell UPS si avvantaggia inoltre del by pass automatico in caso di guasto o di sovraccarico del gruppo di continuit il by pass connette le utenze direttamente alla rete elettrica tramite una linea di riserva consentendo cos di ripristinare le normali condizioni di lavoro senza interruzioni di alimentazione al carico 1 3 1 Stadio di ingresso modulo di po tenza e stadio di uscita Riferimenti schema funzionale 1 3 2 Dalla morsettiera di ingresso la rete viene invia ta tramite l interruttore MAINS INPUT al modulo di potenza Il convertitore step up si incarica della conversione AC DC della rete condiz
80. i batteria 4 devono essere inseriti 1 chiudere l interruttore MAINS INPUT 3 2 Selezionare il menu COMANDI con le frecce lt 3 0 gt 4 e premere ENTER tasti 3 e 4 contemporaneamente per conferma 3 Selezionare INVERTER ON OFF con le frecce lt 3 o gt 4 e premere ENTER Sequenza di accensione tasti 3 e 4 contemporaneamente per conferma si avviano inverter e ventilatori 4 Premere ESC per uscire dal menu COMANDI e posizionarsi su misure segnalazioni e allarmi 4 3 5 BATTERY fuses switch Connect the battery to UPS inner circuitry This manual fuse holder switchescan be open or closed only with external battery isolator open because they aren t capable to operate on loads so the are used only to put on safety the UPS during maintenances 4 4 USER S GUIDE 4 4 1 Accensione del UPS UPS ON OFF switches are located behind the doorwith the leversettithe horizontal position to denote OFF condition Before switching UPS ON check that the MANUAL BY PASS switch is locked to the horizzontal position with a mechanical lock and eventually the pad lock Toactivate UPS proceed to operate the switches following the order giveb below WARNING Bypass SWitch 2 must be open andbattery fuses must be inserted 1 close the MAINS INPUT switch 3 2 press the MENU pushbutton choose the COMMAND MODE menu sing the arrows lt 3 or gt 4 and press ENTER pushbuttons 3 and 4
81. i da realizzare sono schematizzati in Fig 2 2 LE OPERAZIONI DESCRITTE NEI SUCCES SIVI PARAGRAFI DEVONO ESSERE ESE GUITE DA ELETTRICISTI AUTORIZZATI O DA PERSONALE TECNICO QUALIFICATO rete 380 415Vca 50 Hz 3fase N PE GND mains 3802415 Vac 50 Hz 3ph N PE GND Interruttore magnetotermico Curva C Magnetothermic switch 1 Curve C TTI Li a 1l_ otel RSTN 500 mA MAINS To guarantee that the UPS and relative optional equipment operate properly a mains point must be provided both at the input and output of the equipment which must also be provided with the specific protection devices The wiring connections to be executed are shown in Fig 2 2 THE OPERATIONS DESCRIBED IN THE FOL LOWING PARAGRAPHS MUST BE CAR RIED OUT BY AUTHORIZED ELECTRICIANS OR BY TECHNICAL PERSONNEL Interruttore di By pass UPS normalmente aperto UPS By pass switch normally open Interruttore magnetotermico Curva C Magnetothermic switch Curve C Interruttore magnetotermico quadripolare differenziale per correnti alternate pulsanti con componente continua contraddistinto dalla presenza del simbolo NIA Il valore minimo di intervento deve essere a c four pole safety magnetothermic switch push button with dc component distinguished by symbol A e l l INIA The
82. ials Disposal of other parts The disposal of other parts making up the UPS i e rubber gaskets plastic materials and wiring is assigned to Companies specialised in the disposal of industrial materials X Premessa Foreword UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 A 5 10 DOMANDE FREQUENTI FAQ Come installare l UPS Per installare l UPS consultare Cap 2 Installazione Per installare l armadio batterie consultare Allegato 1 Armadio batterie Per installare l armadio trasformatore consulta re Allegato 2 Armadio trasformatore Personale richiesto tecnici elettricisti Come mettere in funzione l UPS Se l UPS viene acceso per la prima volta consultare Cap 3 attivazione Personale richiesto tecnici collaudatori Per tutte le altre volte consultare Cap 4 Uso e manutenzione 4 4 Personale richiesto generico Devo fare manutenzione all UPS La manutenzione estremamente ridotta con sultare Cap 4 7 Manutenzione ordinaria Personale richiesto generico Le batterie sono scariche che fare Consultare Cap 2 5 1 come ricaricare le batterie Personale richiesto generico Vorrei addestrare tutto il personale alle ope razioni pi semplici sull UPS che fare Svolgere un rapido corso di addestramento sugli argomenti trattati nei seguenti capitoli PREMESSA Cap 4 Uso e manutenzione Personale richies
83. ic by pass The switching over to the reserve line test is carried out by forcing the automatic By pass circuit to intervene and by checking that the load is still being powered Commutazione su linea di riserva a premere il pulsante 1 MENU b Selezionare il menu COMANDI con le freccie lt 3 o gt 4 e premere ENTER tasti 3 e 4 contemporaneamente per conferma Switching over to the reserve line a press the MENU pushbutton 1 b Choose the COMMAND MODE menu using the arrows lt 3 or gt 4 and press ENTER pushbuttons 3 and 4 togheter to confirm c Selezionare COMMUTAZIONE CARICO con le freccie lt 3 o gt 4 e premere ENTER tasti 3 e 4 contemporaneamente per conferma d Premere ESC per uscire dal menu COMANDI e posizionarsi sul menu segnalazioni e allarmi e ritorno alle condizioni normali con segnalazione sull CD Carico su Inverter c Choose INVERTER ON OFF using the arrows lt 3 or gt 4 and press ENTER pushbuttons 3 and 4 togheter to confirm d Press ESC pushbutton to exit from COMMAND MODE menu to visualize the status and alarm menu e return to normal condition with LCD display status Load on Inverter Se non si verificano ulteriori eventi PUPS torna automaticamente in funzionamento normale dopo 20 secondi 3 1 7 Verifica del funzionamento del By pass manuale Il By pass manuale permette di
84. ilenziare l allarme 4 7 2 Ricarica della batteria La ricarica delle batterie avviene automatica mente in presenza della tensione di rete mante nendo il UPS acceso Nel caso di batteria scari ca dovuta a cause eccezionali come una prolun gata assenza della rete si consiglia di eseguire la ricarica durante le ore di inattivit lavorativa es chiusura notturna con le utenze spente Dopo circa 10 12 ore di ricarica si raggiunge 80 del massimo livello di carica 4 7 3 Verifica periodica del funziona mento della linea di riserva Una volta al mese eseguire la commutazione sulla linea di riserva e verificare che Il carico continui ad essere alimentato La procedura la stessa descritta al paragrafo 3 1 6 Se non si verificano ulteriori eventi l UPS torna automaticamente in funzionamento normale dopo 20 secondi 4 7 ROUTINE MAINTENANCE WARNING The tests described below could cause loss of data on the UPS powered PCs It is suggested to carry out the tests taking secu rity measures e g utilizing uncritical loads or avoiding operations that could cause loss ofdata on the system 4 7 1 Check on UPS intervention Carry out this test on a monthly basis cut UPS off from the input mains by opening the INPUT switch and check that the load is still being regularly powered from UPS only openthe INPUT switch the following lights will glow red general alarm light 6 with quenchable buzzer alarm Press button
85. inserzione del carico AVVERTENZA L allarme di Sovraccarico Inverter sull LCD indica un sovraccarico dell UPS il carico con nesso troppo elevato scollegare l utenza in eccesso far ripartire l inverter seguendo la pro cedura di accensione inverter 3 1 2 Check on the status state of the front panel and signalling LEDs When switching ON the UPS will set to the automatic By pass condition thus producing a generic alarm red LED glowing andbuzzeralarm activated Press the quenching key to clear the buzzer alarm After 20 seconds that the inverter has been started the UPS will revert to the regular operat ing conditions This condition is indicated on the front panel through the LCD above described fig 2 3 3 1 3 Load insertion test Dummy loads are suggested to be used till reaching the maximum UPS power With an eye to the load indicating LEDs gradually insert the load WARNING The Inverter Overload alarm indicates that the UPS is overloaded the load connected is too high disconnect the load in excess restart the inverter following the Inverter On Off procedure ATTIVAZIONE SETUP Attivazione Setup 3 3 UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 3 1 4 Prova di mancanza rete dell UPS SETUP ATTIVAZIONE La verifica dell intervento del UPS o commuta zione del funzionamento RETE BATTERIA si effettua staccando
86. io armadio UPS equipped in its cubicle Le batterie sono escluse Batteries aren t provided INFORMAZIONI GENERALI GENERAL OVERVIEW 1 4 Informazioni generali General overview UPS 60 120kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 A 1 2 2 Armadio batterie 1 2 2 Batteries cabinet Ove richiesto l UPS pu essre fornito UPS can be supplied with a suitable battery completo di batterie per l autonomia richiesta cabinet for the required autonomy Cabinet Le batterie possono esere alloggiate in armadio contains also dc isolator to disconnect battery di dimensioni opportune completo di organi di when necessary lf battery location is not near sezionamento the UPS a wall cabinet containing battery Nel caso di batterie non installate in prossimit isolator must be provided near UPS dell UPS deve essere previsto un opportuno quadretto di sezionamento a parete da installare in prossimit dell UPS asformatore di isolamento galvanico per An optional cabinet with a galvanic isolating npieghi specificicome ad esempio applicazioni transfomer is available and this is spe ospedaliere Il trasformatore standard trifase cifically utilized in medical centers trifasecon rapporto 1 1 ma pu essere fornito Thestandardtransformerfeatures a three phase con rapporto di trasformazione secondo richiesta three phase with 1 1 ratio characteristic the Nello sta
87. io il reimballaggio dell apparecchiatura es restituzione Invio a centri di manutenzione traslochi Verificare che il gruppo non abbia subito danneggiamenti in caso contrario contatta re immediatamente il rivenditore 2 1 5 Immagazzinamento Nel caso in cui l apparato non venga imme diatamente installato occorre immagazzinarlo in un ambiente in grado di proteggerlo sia dall ec cessiva umidit sia da fonti di elevato calore da 5 a 40 C umidit minore del 95 non condensante Nel caso sia fornito il quadro batteria ssicurarsi inoltre che tra l ultima ricarica delle batterie e la successiva non trascorra no pi di 6 mesi Trascorso tale periodo proce dere all allacciamento provvisorio dell UPS alla rete e attivarlo per il tempo necessario ad effet tuare la ricarica delle batterie Vedere 2 5 Allacciamento provvisorio per la ricarica delle batterie Remove the cellophane wrapping utilized as protection packing Slide the forks of the lift truck under the UPS and after having lifted it a few centimeters from the floor back up and lay it down UPS is provided with wheels to easily move it around Do not throw away the packing material in that it might be used again to repack the equipment if having to send it back or to send it to maintenance centers or for re moval purposes Check that the equipment has not been damaged If otherwise immediately contact the Sales Representative 2 1 5
88. ione dell UPS Quindi collocare l UPS nella posizione idea le per il servizio Connect the UPS output cable to termi l nals 15 ground 11 12 13 phase and 14 neutral of the Curve C magnetothermic switch on the User Dis tribution Panel Outputs ofthe Curve C switch must be parallel connected to the user sockets it is suggested to setup this link using other safety magnetothermic switches one per socket the magnetothermic switches will if necessary isolate each single user The characteristics of the magnetothermic switches to insert at the user input and the cable sections are based on the loads applied to the various sockets At the end of every connection assembly again the protection panel on the UPS tagblock Place UPS into the position considered most fitting for the use Installazione nstallation 2 13 INSTALLAZIONE INSTALLATION UPS 60 120kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 2 3 ALLACCIAMENTO A DISPO 2 3 EXTERNAL DEVICES CON INSTALLAZIONE INSTALLATION SITIVI ESTERNI Sul pannello posteriore dell UPS disponibi le una scheda Rel per collegare l UPS a un pulsante di spegnimento d emergenza dell UPS E P O Emergency Power Off Tramite un connettore DB9 la scheda consente inoltre di collegare l UPS a un Personal Compu ter e mediante la morsettiera posta sulla stessa di colleg
89. ione di normale funzionamento oppure della conversione DC DC dell energia della batteria quando la rete assente o fuori dalla tolleranza consentita La corrente continua alimenta poi l inverter che ricostruisce l alternata adeguando il prelievo in funzione delle esigenze del carico Segue poi il by pass automatico anch esso pilotato dalla logica di controllo che in condizioni normali invia in uscita l energia rigenerata e filtrata del Modulo di potenza A 1 3 OPERATION UPS is an On line type uninterruptible power unit with double conversion and with automatic by pass compliant with the EN50091 1 3 ANIE definition Ups CIB European Standard Since there is no direct mains load connection there is no interference and the double conver sion guarantees a regenerated voltage and frequency output power always therefore it is O ideally employed by professional users When the input voltage deviates from the al lowed tolerance the batteries will give the power to deliver to the load The UPS User also makes use of the automatic by pass The presence of failure or of overload on the uninterruptible power unit will cause the by pass to directly connect the userto mains through a reserve line thus restoring the regular operat ing conditions without loss of power to the load VERVIEW L GENERA 1 3 1 Input Stage Power Module and Out put Stage Reference Functional drawing 1 3 2 The mains voltage is del
90. isto per tutti i casi in cui occorra escludere l UPS mantenen do alimentato il carico es UPS fermo avaria Si tratta di un circuito azionabile tramite l interruttore MANUAL BY PASS che si trova nella parte anteriore dell UPS aprendo la porta L interruttore dispone di un fermo meccanico di protezione per impedire che venga azionato inavvertitamente Il fermo meccanico bloccabile con lucchetto per evitarne la rimozione da per sonale non autorizzato 4 1 1 Operation The dual operating modes of UPS are from MAINS with mains present the load is kept powered by the mains voltage which is filtered and rectified by UPS the battery is idle and constantly charged This is the regular op erating condition from BATTERY with no mains voltage present the battery yields the power required to supply the load In this manner power is guaranteed to the con nected load even with no mains present The switching over from MAINS to BATTERY is automatic and immediately following mains fail ure Likewise when mains is restored the equip ment reverts to the regular operating condition 4 1 2 Automatic By pass When UPS detects faulty conditions e g bat tery or circuitry failure or excessive tempera ture an automatic switching circuit will auto matically intervene to by pass over to a tran sient path On this path the mains will continue powering as long as the automatic switching circuit intervenes When the
91. ivered by the input tagblock to the power module through switch MAINS INPUT The step up converter AC DC converts mains regular operating condition or DC DC con verts battery power when mains has either failed or is not within the set tolerance The DC powers the inverter which reconstructs the AC by adapting the power extracted vs load requirements An automatic by pass follows driven by the control logic In regular operating conditions it delivers the power module s regenerated and filtered power to the output As already stated when a faulty or overload condition arises the automatic by pass switches over to the reserve line In this manner the load ONI GENERAL NFORMAZ Informazioni generali General overview 1 7 MAIAIBAO BJQUIH C1BUSBH IUOIZELUIOJU Q INFORMAZIONI GENERALI GENERAL OVERVIEW N ingresso rete mains input By pass line Ups excluded OUTPUT Convertitore step up step up converter Inverter automatico automatic By pass 3 F N PE 3PH N PE a 3F N PE 3PH N PE MODULO DI POTENZA POWERMODULE mmm 40 Pes PANNELLO FRONTALE FRONT PANEL Ups in funzione NOTA NOTE SCHEDA 1 i Ups run Interruttori e contatti di rel sono RELE i By pass inserito illustrati a Ups spento RELAYS By pass on Switches and relay contacts shown BOARD b Presenza rete 400 VCA 400 VAC mains presence Batt
92. iz 00 Technical handbook DT0342 Issue 00 N Stato del pannello frontale all accensione dell UPS Front panel status when switching ON the UPS Sull LCD 7 verranno visualizzati i seguenti stati UPS in funzione inverter inserito rete principale OK rete di riserva OK tensione di batteria OK sincronismo OK Carico su Inverter Il led verde 5 indicher la condi zione dell UPS di funzionamento On LCD 7 will be displayed the following statusi UPS operating inverter operating mains line within limits by pass line within limits battery voltage within limits inverter bypass in syncro load on inverter 3 1 2 Verifica dello stato delle segnalazioni sull LCD del pannel lo frontale Al momento dell accensione l UPS si pone in By pass automatico dando origine all allarme gene rico LED rosso acceso e allarme sonoro Premere il tasto di silenziamento ESC per escludere l allarme sonoro Dopo 20 secondi che l inverter stato avviato UPS si pone in condizione di funzionamento normale indicata sul pannello frontale dall LCD sopra descritto fig 2 3 3 1 3 Prova di inserimento del carico Si suggerisce di utilizzare carichi fittizi o carichi non critici fino al raggiungimento della potenza massima dell UPS Tenendo sotto controllo la potenza o corrente di uscita indicata nel menu parametri dell LCD procedere gradualmente al l
93. l acquirente non accetta responsabili t per danni conseguenti a tali applicazioni LIFE SUPPORT APPLICATIONS Due to the variety of applications and involved standards in each case does not recommend or knowingly sell it s product for any use not perfectly conscious Applications where UPS malfunctions or inadequacy give rise to risk of human life shall be sole responsibility of the purchaser accepts no liability for consequential harm in such applications dati contenuti nel presente manuale sono dati dal Costruttore con riserva di modificarli in ogni momento senza preavviso Information in this handbook are given by the Manufacturer which reserves the right to modify them without any notice UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 INDICE GENERALE PREMESSA Acli PIONIO SOCCONSO pri V A 2 Norme di sicurezza VI A 3 Istruzioni di sicurezza IX A 4 Demolizione e smaltimento X A 5 10 domande frequenti FAQ XI 1 INFORMAZIONI GENERALI 1 1 Descrizione generale dell UPS 2 1 2 Configurazioni ed equipaggiamenti ODZIONAl irritato 4 1 3 Principio di funzionamento 8 2 INSTALLAZIONE Cid INIFOGUZIONE siglato alle 3 2 2 Allacciamento dell UPS alla rete 8 2 3 Allacciamento a dispositivi esterni 14 2 4 Scheda Rel op
94. llarme minima quella di avere quella la V batt a 320Vdc 2 3 1 5 Test on the battery charge condi tion With the load powered through the UPS only INPUT MAINS switch lever horizontal check on the LCD front panel the battery parameters Vbatt batt Back up time the normal condition is to have Vbatt be tween 370 430Vdc and back up time between 90 100 indicative values depending on load applied the BATTERY PREALARM condition is Vbatt between at 350Vdc 2 the BATTERY VOLTAGE OUT OF LIMITS condition minimum alarm is Vbatt between at 320Vdc 2 3 4 Attivazione Setup UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 Se si protrae ulteriormente l utilizzo della batte ria verr visualizzato l allarme fine scarica bat teria l inverter viene automaticamente arresta to e la macchina non riparte sino al rientro rete 3 1 6 Prova di commutazione su linea di riserva By pass automatico La prova di commutazione su linea di riserva si effettua forzando l intervento del circuito di By pass automatico e verificando che il carico con tinui ad essere alimentato If the battery is further utilized the alarm BAT l TERY END OF DISCHARGING will be dis played inverter is automatically stopped and the UPS willnotrestartuntil mains willbe restored 3 1 6 Test on switching over to the re serve line automat
95. llazione Installation 2 17 UPS 60 120kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 p s ALLACCIAMENTO PROVVI INSTALLAZIONE INSTALLATION SORIO PER LA RICARICA DELLE BATTERIE LE OPERAZIONI DESCRITTE IN QUESTO PARAGRAFO DEVONO ESSERE ESEGUITE DA ELETTRICISTI AUTORIZZATI O DA PER SONALE TECNICO QUALIFICATO 2 5 1 Verifiche e predisposizioni Prima di procedere al collegamento dell UPS verificare 1 i valori della tensione e della frequenza di rete essi dovranno corrispondere a quelli indicati sull etichetta adesiva presente sulla parte posteriore dell UPS tensione di in gresso frequenza di lavoro 2 la portata dell interruttore magnetotermico deve essere uguale o maggiore di quella indicata sull etichetta adesiva presente sul la parte posteriore dell UPS KVA 3 lamessaaterra dell impianto deve essere conforme a quanto previsto dalle norme IEC o dalle norme localmente vigenti Per la sicurezza del personale addetto all installazione assicurarsi che le operazioni di collegamento vengano effettuate nelle seguenti condizioni assenza della tensione primaria di rete UPS totalmente disattivato Per disattivare totalmente l UPS a aprire leva in posizione orizzontale OFF gli interruttori di ingresso rete 1 di linea di riserva 2 di uscita 4 2 5 TEMPORARY CONNECTION TO ENABLE BATTERY RE CHARGE THE OPERATIONS DESCRIBED IN THE PAR
96. llo remoto opzionale le cui spie informa no sullo stato dell UPS A richiesta viene fornita una seconda scheda rel opzionale con le stesse funzioni di quello standard L UPS stato progettato e realizzato per offrire elevate prestazioni in termini di sicurezza pro tezione ed affidabilit l UPS si rivela perci ido neo a servire carichi sofisticati ed altamente sensibili alle fluttuazione ed alle microinterruzioni d alimentazione della rete operating switches hidden from sight to prevent them from being accidentally operated The two slots are reserved for a standard DB9 connector used to connect UPS to a PC The Constructor supplied program residing on the PC allows to manage UPS operation To the tagblock residing on the same board a remote panel optional can be connected The lights presenton the remote panel reports on the UPS state of operation An additional Relay Board optional with func tions similar to the standard one is supplied upon customer demand UPS has been designed and constructed with the aim of offering high performance in terms of safety protection and reliability UPS is there fore suitable to serve sophisticated loads which are highly sensitive to surges and micro inter ruptions on the mains power Pannello Remoto Remote Panel Uso e manutenzione User manual 4 3 USO E MANUTENZIONE USER MANUAL USO E MANUTENZIONE USER MANUAL UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 e
97. mancanza di rete abbassando l interruttore INPUT MAINS sull UPS 2 verificare che sul pannello di segnalazione remoto si accenda il LED rosso RECTIFIER 4 3 verificare l intervento dell allarme sonoro sul pannello remoto premendo il tasto BUZZER l allarme sonoro viene silenziato Prova del pannello remoto Remote panel test UPS REMOTE MONITOR 1 simulate mains absence by lowering the lever of the INPUT switch on the UPS 2 check that red LED RECTIFIER 4 light up on the remote indication panel 3 check that the buzzer alarm intervenes on the remote panel press the BUZZER key to quench the alarm 3 3 3 Verifica delle telesegnalazioni in uscita dalla scheda Rel W Sulla morsettiera M della scheda Rel sono disponibili contatti liberi da tensione di tipo NO NC relativi agli stati dell UPS descritti nella tabel la seguente a UPS spento i contatti NC sono in continuit con il rispettivo comune ETUP Morsetti Segnalazioni UPS in funzione N O comune UPS in avaria N C By pass inserito N O ATTIVAZIONE By pass disattivo N C Mancanza rete 230 VCA N O comune Presenza rete 230 VCA N C Livello batteria sufficiente N O comune Batteria scarica N C Accertarsi della corretta corrispondenza di quanto descritto misurando la continuit ohmica fra il comune e relativi contatti mediante un
98. mbH Hamburg Germany Advanced User Annulla 3 8 Attivazione Setup UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 3 3 ATTIVAZIONE DEI DISPOSITIVI PERIFERICI In questo paragrafo sono date le istruzioni per il collaudo di impianti esterni e dispositivi periferici collegati all UPS quali il pulsante di spegnimento in emergenza il PC il pannello remoto 3 3 1 Verifica del circuito di spegnimen to forzato in emergenza E P O Il circuito pensato per spegnere l UPS in condi zioni diemergenza incendio allagamento ecc utilizza un pulsante esterno di emergenza con contatti NC collegati alla scheda Rel Per verificare il corretto funzionamento eseguire le manovre descritte nel riquadro sottostante AVVERTENZA se le condizioni sopra descritte non fossero verificate controllare i ponticelli della scheda Rel paragrafi 3 2 1 3 3 PHERIPHERAL DEVICE SET UP This paragraph reports the instruction to be followed when testing the external plants and the peripheral devices connecting UPS i e the safety ON OFF switch the PC the remote panel 3 3 1 Check ofthe Emergency Power Off circuit E P O This circuit has been designed to switch off the UPS in emergency conditions i e fire flood etc It utilizes an external safety switch with NC contact connecting the Relay card To check that it operates correctly proceed a
99. mmutazione carico il comando di trasfe b Swicthloadis the command for tranferring the rimento momentaneo 20sec del carico in usci output load 20sec on automatic bypass line ta sulla linea di riserva Questo comando anche usato per resettare la This command it is also used to reset the Static condizione di Commutatore Statico Bloccato Switch Locked condition condition that happen condizione che avviene in caso di spunti elevati for high inrush currentof the load on the inverter del carico sull inverter per tre volte consecutive for three times consecultive USO E MANUTENZIONE USER MANUAL c Battery test il comando manuale per la c Battery test is the manual command to verity verifica della batteria Il comando attiva il circuito the battery The command activate the control di controllo della batteria che ne verifica la condi circuit of the battery that will verify the good zione condition Uso e manutenzione User manual 4 9 UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 4 STORICO EVENTI in questo menu l uten te pu vedere e scorrere gli ultimi 500 eventi avvenuti in ordine cronologico La visualizzazione degli eventi possibile premendo ENTER sul menu VISUALIZZA EVENTI Il display visualizzer data e ora dell ultimo evento Pre mendo il tasto BACK sar possibile scorrere data e ora degli eventi premendo il tasto NEXT sar possibile visualizzare gli stati
100. nominale 30 minuti Potenza erogabile da UPS ATLAS Pnom 40 4 T T ma I 120 o cosfi0 8R E sovraccarico 15 A permanente 80 40 0 40 80 120 P reattiva La SHT POWER si riserva i diritti di modificare i dati del presente documento senza alcun preavviso Pag 8 11 Documento DT0340 Rev 02 21 01 2003 Specifica Tecnica ATLAS 60 120 kVA Decadimento potenza resa UPS in funzione della temperatura tutte le taglie Potenza resa CO NO t amb C 60 La SHT POWER si riserva i diritti di modificare i dati del presente documento senza alcun preavviso Pag 9 11 Documento DT0340 Rev 02 21 01 2003 Specifica Tecnica ATLAS 60 120 kVA Tabelle Rendimento UPS ATLAS in funzione del carico 80 100 120 60 Rendimento macchina 25 Pnom 88 5 89 5 90 90 5 __ 92 5 92 7 90 5 9 92 9 oe oo ooo mo o o _o_o_o _zEzsSm w 5 Om miya a i Distorsione tensione uscita UPS ATLAS in funzione del carico P nominale KVA 80 100 120 ro rr 0_uu u_ u0uuvu_u u_mu_r _m m_t LRtz amp CEI EN 50091 3 50 P nom Tabella fattore di potenza rete alimentazione UPS ATLAS in funzione del carico e del filtro per abbattimento arm
101. ntit di idrogeno nella stanza batterie diviene eccessiva Garantire un adeguata ventilazione del locale batte rie in conformit allo Standard EN50091 1 per evitare il rischio di esplosione Se la temperatura media supera i 25 C si riduce la durata della batteria Il rapporto generalmente 1 2 durata per un incremen di Overheating To preventoverheating do not obstruct the ventilation openings for flow of air of the unit DON T leave objects on the top of the unit Electrical caution Dangerous voltage is present inside the unit The User must not open the Ups cabinet or auxiliary cabinets the components in side the unitare not repairable by the User Moreover do not remove any protective covers from inside the Ups cabinet Allprm ary power swiches nstaled up steam ofthe Ups mustbe Hbelkd as flbws Sohte UPS UnintemptbEPower Supp befor working on ths ccur Emergency Power Off The unit is provided with the E P O Emer gency Power Off This function is acti vated by pressing the external emergency button to which the Ups has been con nected This function provides Ups dis connection from the load and from the battery Dangerous voltage will still be present in side the unit charged capacitors wait for 5 minutes before working on the unit Batteries During electrolysis batteries release hy drogen gas There is arisk ofanexplosion if the amount of hydrogen in the battery room becom
102. o 3 1 1 del ma nuale d uso 4 26 Uso e manutenzione User manual UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 4 10 TROUBLESHOOTING ALARM INVERTER OFF INVERTER OVERLOAD BATTERY NOT CONNECTED BATTERY END OF DISCARGING BATTERY PREALARM BATTERY CHARGER FAILURE BYPASS SWITCH FAILURE STATIC SWITCH LOCKED BYPASS LINE OUT OF LIMITS MAINS OUT OF LIMITS MANUAL BYPASS ON EMERGENCY POWER OFF Uso e manutenzione User manual 4 27 CAUSE Initial start up Permanent output overload or output short circuit Permanent output overload or output short circuit Battery breaker off or battery not connected Battery test fail Mians missing for long time Battery almost flat next to shutdown One or more phase in the output are missing High output inrush current Bypass line voltage out of the specified limits Mains line voltage out of the specified limits UPS on maintenance EPO command activated di ACTION Start the Inverter Check the loads connected to the UPS Check the loads connected to the UPS Switch on the batery fuses or connect the battery Check the battery elements Make shutdown to the connected loads Call sevice office to replace the battery charger Check Bypass SCR Checkthe loads connected and reset to normal condition Check the bypass line voltage Check the mains line voltage Investigate on cause Switch
103. oniche opzionale P nominale KVA 60 80 100 120 bd a _0ua0d0q q Input power factor 12 pulse rect 50 P nom 75 P nom 100 P nom La SHT POWER si riserva i diritti di modificare i dati del presente documento senza alcun preavviso Pag 10 11 Documento DT0340 Specifica Tecnica Opzioni Pannello remoto a Led Armadio batteria Bypass manuale esterno Trasformatore di isolamento uscita esterno Riduttore di armoniche corrente assorbita esterno Comunicazione Remota via RS232 Interfacciamodem Adattatore ethernet SNMP Scheda rel Contatti rel disponibili su morsettiera o Db9 capacit Segnali trasferiti Software di monitoraggio remoto UPS Rev 02 21 01 2003 ATLAS 60 120 kVA predisposto per autonomie di 30minuti e 1 ora in tutte le configurazioni 250Vac 10A Rete presente Inverter in funzione Preallarme di batteria By Pass ON Contatto Win NT Allarme comune Porta di comunicazione RS232 Morsetto disponibile per Emergency Power Off remoto UPS Management Software Suite Unix Linux Novell Windows MacOS Supported La SHT POWER si riserva i diritti di modificare i dati del presente documento senza alcun preavviso Pag 11 11
104. ore premere il tasto MENU Quando si impostata correttamente la Data o l Ora premere ENTER per confermare UPS 60 120kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 CLOCK the menu allows to the user to modify date and time set on UPS Toselect Date or Time press NEXT pushbutton from CLOCK menu then press ENTER to modify STATUS ALARM MENU q F i lt 00 00 00 to set date e nn a do lt 00 00 00 to set time When the Date or Time are displayed the cursor will be located onthe first right charachter To increase or decrease the charachter use the NEXT and BACK pushbuttons to move the cursor on the left pree MENU pushbutton When the Date or Time are set correctly press ENTER command to confirm 4 12 Uso e manutenzione User manual UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 CONFIGURAZIONE il menu permette di cambiare parametri dell UPS E fortemente raccomandato che solamente personale qualificato utilizzi il presente menu In questo menu all utente permesso solamen te l inserimento e la modifica del numero di telefono dell assistena tecnica Per l accesso selezionare numero di telefono e premere ENTER per confermare Per incrementare o diminuire la cifra usare i tasti NEXT e BACK per spostare a sinistra il cursore premere il tasto MENU Quando si impostata correttamente il nume
105. potenza dell UPS lap parato che si presenta con una modernalinea costituito da una struttura portante in lamiera zincata montata su ruote che ne agevolano brevi spostamenti la struttura portante coperta da un mantello esterno in lamiera accuratamen te verniciata 1 1 1 Campi di utilizzazione dell UPS Il nuovo UPS progettato per fornire alimenta zione stabilizzata e filtrata a sofisticate apparecchiature elettroniche in particolare a sistemi per l elaborazione dei dati alle quali deve essere garantita una sorgente di alimentazione esente da fluttuazioni di tensione e frequenza quindi ospedali stazioni di polizia gallerie auto stradali stazioni radioemittenti banche uffici tecnici e amministrativi e molte altre applicazio ni 1 1 2 Potenza e autonomia Grazie alla progettazione modulare l UPS di sponibile nelle versionicon potenza nominale da 60kVA a 120KVA tutte con cos 0 8 Tutte le taglie non hanno batteria all interno ed previsto l utilizzo di armadio batteria separato per qualunque autonomia 1 1 3 Sicurezza e facilit d uso Tutti comandi disponibili sono perfettamente isolati e disaccoppiati da elevate tensioni di lavo ro cos come stata posta estrema attenzione all isolamento e separazione galvanica riservata alle parti esterne del contenitore 1 1 UPS GENERAL DESCRIPTION The small outer size of the cabinet hides the extraordinary power of UPS The equipment has a mo
106. r a net work of PCs UPS can be managed through the Windows NT application Management through the UPS Management software optional al lows to automatically switch off the network s local and remote PC to monitor the main func tions of UPS the SNMP protocol etc A full description of the functions and modality of use is given in the UPS Management software 4 20 Uso e manutenzione User manual UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 4 6 PANNELLO REMOTO 4 6 REMOTE PANEL di OPZIONALE OPZIONAL Il pannello di segnalazione remoto consente con The remote indication panel allows through its le sue spie luminose di supervisionare le princi lights to supervise the main functions and oper pali funzioni e stati operativi del UPS anche se ating statuses of UPS even if It is sited at a quest ultimo si trova distante dalla zona operati distance from the control operative area va di controllo HPS DBASE MAMI OH BVLLIFHA rs ee FELE LFF ma ee Fey ete Bhar ae VI HN SIFEMCE iht ams ia Pad WEE DM BAbT s ci Legenda delle spie sul Pannello Remoto Legend of the lights present on the Remote Panel Spia verde UPS ON accesa funzionamento 1 Green UPS ON light glowing to indicate regolare dell UPS regulary operating Spia gialla ON BATTERY accesa funzionamento 2 Yellow ON BATTERY light if glowing it indicates da batteria dell UP
107. ria e pu essere rimosso dal locale in cui installato l UPS mediante un sistema di ventilazione raffreddamento forzato o un sistema ad aria condizionata i Usi consentiti L unit deve essere usata secondo le fina lit previste Seguire le istruzioni riportate nel Cap 4 Istruzioni per l uso A 2 SAFETY RULES Maximum load on the floor According to the weight of the UPS Sys tem see chapt 1 5 Characteristics the installation site must have a floor capable to carry the equipment weight When in doubt consult the building firm Room accessibility The room must be suitable to permit all installation manoeuvres consider the door dimension in order to facilitate the pas sage of the equipment For equipment moving a transpallet capable to lift the UPS weight is required Room dimensions and pollution Allaround the UPS a minimum free space enough to guarantee the correctexecution of maintenance jobs must be kept Be tween the top of the UPS and the installa tion site ceiling the minimum distance must be at least 400 mm Room has to be clean and without conductive dusts max pollu tion degree 2 Ventilation The UPS working temperature is in the range0 Cto40 CT Theidealenvironmen tal temperature should not exceed 25 The UPS heatis extracted by internal fans and dissipated in the air the heat can be removed from the room in which the UPS is installed by means of a fan system forced ventilation or
108. rli immediata mente con una soluzione d acqua salina o con acqua corrente per almeno 10 minuti Persone che hanno ingerito liquidi corrosivi Qualora l elettrolito delle batterie venisse ingerito non provocare il vomito ma con sentire all infortunato di bere acqua o latte in grande quantit IN TUTTI CASI CHIEDERE IMMEDIATAMENTE L AIUTO DI UN MEDICO A 1 FIRST AIDS Emergency Power Off In an emergency case the load supply can be disconnected opening all the lever switches fitted in the frontlower side of the UPS opening the door First aids for electric shock Turn off or open the power supply line or use anisolated dry material to protect itself while moving the victim far away from any electrical cable DO NOT TOUCH THE VICTIM WITH HANDS UNTIL THE LATTER IS FAR AWAY FROM ANY ELECTRIC WIRE SEEK IMMEDIATELY FOR MEDICAL HELP People contaminated by corroding liquids Should the batteries electrolyte come into contact with skin rinse abundantly with water the skin remove the contaminated clothes apply dry gauze to the contami nated skin Should the batteries electrolyte come into contactwith eyes wash them immediately with a saline water solution or with fresh water for 10 minutes at least People having ingested corroding liq uids Should the batteries electrolyte ingested do not induce vomiting but let the victim drink as much water or milk as he likes AT ALL EVENTS SEEK IMMEDIATELY FOR MEDI
109. ro di telefono premere ENTER per confermare MENU STATI ALLARMI CONFIGURAZIONE UPS NUMERO DI SERIE NUMERO DI TELEFONO per Impostare n tel CAPACITA BATTERIA TARATURA PARAMETRI UPS CONFIGURATION the dl allows to modify parameters of UPS It is strongly reccomended that only trained people can access to this menu In this menu the user can only add or modify the service phone number To select this menu choose phone number and press ENTER to confirm To increase or decrease the charachter use the NEXT and BACK pushbuttons to move the cursor on the left pree MENU pushbutton When the Date or Time are set correctly press ENTER command to confirm STATUS ALARM MENU UPS CONFIGURATION SERIAL NUMBER PHONE NUMBER to set service phone n BATTERY CAPACITY CALIBRATION Uso e manutenzione User manual 4 13 USO E MANUTENZIONE USER MANUAL USO E MANUTENZIONE USER MANUAL UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 4 3 QUADRO ELETTRICO ANTERIORE Il quadro elettrico dell UPS si trova nella parte anteriore in posizione volutamente nascosta per evitare manovre involontarie o accidentali Contiene tutti gli interruttori che attivano disattivano UPS Legenda degli interruttori nel quadro elettrico Interruttore di ingresso rete Interruttore di ingresso linea di riserva Interruttore di By pass manuale Interruttore di usci
110. rst aids for electric shock V Persone venute in contatto con liquidi People contaminated by corroding CONO V NOUIS siniese anini AE V Persone che hanno ingerito liquidi People having ingested corroding COMOSNI att ti V NINOS LA ani V A 2 Norme di sicurezza VI AZ Safety rule S inon VI Carico sul pavimento del locale di Maximum load installazione VI ON the flOOF VI ACCESSO ai locali cccucecucecececccecececececececcie VI Room accessibility VI Dimensioni dei locali VI Room dimensions VI VETUTAZIONE ssie VI Ventilation iiii VI USI GONSENt Moena VI Allowed use VI Surriscaldamento VII Overheating i VII Precauzioni elettriche VII Electrical CAUTION VII Arresto IN emergenza VII Emergency Power Off VII Batterie puoi VII Batteries xxxxxr VII Guanti protettivi VIII Protective gloves VIII Tappeto isolante VIII Isolating carpet VIII Spogliarsi degli oggetti di metallo
111. s described below WARNING If the above conditions are not veri fied check the straps on the Relay card see paras 3 2 1 Prova di spegnimento E P O Switch off test on the E P O EPO Remoto Remote EPO a Premere il pulsante di Emergenza esterno l Ups a Press the external EMERGENCY pushbutton the si spegne entro 2 secondi e cessa di alimentare Ups switches off within 2 seconds and stops il carico allarme acustico e accensione allarme gen 6 powering the load buzzer alarm and general alarm b Per ripristinare spegnere completamente l UPS e aspet activation tare alcuni minuti perla riaccensione attendere il completo b To reset switch off completely the UPS and wait few spegnimento dell LCD Per la riaccensione ripetere la minutes to restart wait the LCD completely switched procedura di attivazione descritta al paragrafo 3 1 1 off To restart please repeat the start up proce_ della presente sezione dure described on paragraph 3 1 1 of the present section Attivazione Setup 3 9 ATTIVAZIONE SETUP UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 3 3 2 Prova del pannello remoto Per verificare il corretto funzionamento eseguire le manovre descritte nel riquadro sottostante 3 3 2 Remote panel test To check regular operation proceed as stated below T y m ype fet Bet 1 Simulare la
112. s that reported on the freight bill 2 1 3 Identification The equipment supplied is provided with an cati tramite una targhetta ade siva applicata sul pannello po adhesive identification label placed on the UPS rear panel steriore dell UPS sulla quale sono riportati modello e poten reporting type of UPS model andpower za dell UPS Di seguito viene descritta The cases utilized to transport la procedura a cui attenersi per the equipment must be un disimballare correttamente contenitori utilizzati per la spe Targhetta dell UPS UPS Label packed as specified by the pro cedure stated below dizione dei gruppi 2 1 4 Rimozione dell imballo Durante questa operazione rispettare le in dicazioni FRAGILE ALTO riportate sul conte nitore al fine di evitare danneggiamenti dell UPS Per la rimozione dell imballo procedere se condo le istruzioni della seguente procedura fare riferimento alla fig 2 1 Attenendosia quanto riportato sul conteni tore esterno ALTO BASSO posizionare correttamente l apparato sul pavimento Rimuovere il coperchio e i laterali della gab bia di legno 2 1 4 Packing material removal During this operation observe the indica tions FRAGILE UP printed on the case to avoid damaging the UPS To remove the packing material proceed in the following manner see Fi
113. sante EPO Per collegare al UPS pi pulsanti EPO necessario porli in serie tra loro e poi collegare la serie a uno dei CN8 disponibili Sele mol sl morsettiera con morsetti liberi da E morsettiera di collegamento all UPS tensione a disposizione dell Utente UPS connection tagblock collegamento al Pannello remoto 2 2 3 3 morsetti per il collegamento 00 00 00 Tagblock with cold contacts free La E P O vedere fig 2 5 C_________ 6 for the User Remote Panel i connection see para 2 3 3 sui 12 9 N O E P O wiring terminals see ls COM UPSINFUNZIONE LLI Fig 2 5 UPS RUNNING lt 10S N C O 9 NO gv PASSINSERITO NI s CN3 gt i BY PASS ON N rel NC lt 6 9 N O 516 COM PRESENZARETE MAINS PRESENCE N C lt connettore DB9 per il 3 6 N O fe collegamento al Personal 2 9 COM BATTERIASCARICA dp Computer vedere 2 3 2 1 N C BATTERY FLAT O 00000 O Z oes ie az DB9 plug for Personal 0000 ni Computer connection see db9 para 2 3 2 Legenda Legend N O Normalmente aperto Normally open COM Comune Common N C Normalmente Chiuso Normally Closed Fig 2 7 Schema dei collegamenti della scheda interfaccia segnali con rel Signals interface with relay card wiring diagram Insta
114. sso armadio pu essere equipaggiato transformer ratio can be customized untrasformatore perla riduzione delle armoniche Inthe same cabinetcould be equipped a suitable di corrente assorbite da rete transformer for line current armonic LU n S n S O al T OC LU lt LU UPS UPS i lt x Armadio batterie Tr Batteries cabinet gt Lu za O 23 Armadiotrasformatore 1 2 3 Transformer cabinet N E disponibile un armadio opzionale con DC O LL Z Informazioni generali General overview 1 5 UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 N 1 2 5 Accessori Accessories UPS MANAGEMENT SOFTWARE Il software di comunicazione Generex UPS MANAGEMENT permette la comunicazione tra l UPS e un PC o una rete di PC basati su sistema operativo Windows Win NT Novell OS2 Dec Lynux Il software consente di controllare la condizione operativa di uno o pi UPS utilizzati per alimentare una rete locale LAN di Personal Computer The UPS MANAGEMENT Generex interaction software it allows interaction between UPS and a PC or a PC network based on Windows Win NT Novel 0S2 Dec Lynux operation system Software controls the operating condition ofone or more UPS utilized to power a local PC network LAN SCHEDE PERLA COMUNICAZIONE REMOTA REMOTE INTERACTING CARD Una scheda Rel pu essere aggi
115. t 4 8 Troubleshooting Personnel required support technician How to gain informations of the technical commercial type about the UPS Refer to the following documents Chapt 1 General Overview XII Premessa Foreword UPS 60 120kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 1 INFORMAZIONI GENERALI 1 GENERAL OVERVIEW Indice Table of contents 1 1 Descrizione generale dell UPS 2 1 1 UPS general description 2 1 1 1 Campi di utilizzazione dell UPS 2 1 1 1 UPS type of application 2 1 1 2 Potenza e autonomia 2 1 1 2 Power ANd autonomy 2 1 1 3 Sicurezza e facilit d uso 3 1 1 3 Safety and ease ofuse 3 1 1 4 Particolari costruttivi 3 1 1 4 Construction details 3 1 2 Configurazioni e equipaggiamenti 1 2 Configuration and optional OPZIONALI ea 4 equipment sicevesssistszitestessestectasestscis 4 1 2 1 Configurazioni di base 4 1 2 1 Base configuration 4 1 2 2 Armadio batterie 5 1 2 2 Batteries cabinet 5 1 2 3 Armadio trasformatore 5 1 2 3 Transformer cabinet
116. ta alimentazione carico Sezionatore fusibili di batteria VAGONE tou uo ou II 4 3 1 Interruttore INPUT MAINS Questo interruttore consente la connessione della linea d alimentazione esterna 380 415 VAC all ingresso dell UPS 4 3 2 Interruttore RESERVE INPUT Questo interruttore consente la connessione della linea di riserva 380 415 VAC al commu tatore statico dell UPS 4 3 3 Interruttore MANUAL BY PASS Normalmente aperto By pass escluso linter ruttore protetto contro le manovre involontarie da un fermo meccanico con la possibilit di protezione ulteriore mediante la chiusura a chia ve con lucchetto Serve in tutti i casi in cui occorre escludere l UPS mantenendo alimenta to il carico da rete 4 3 4 Interruttore OUTPUT Questo interruttore connette l uscita dell UPS ai vari carichi 4 3 FRONT DISTRIBUTION PANEL UPS distribution panel is situated on the front plane pur posely hidden from sight to prevent unintentional or acciden tal operations lt comprises all the switches used to activate de activate UPS Legend of the switches present on the distribution panel 1 Mains input switch 2 Reserve line switch 3 Manual By pass switch 4 UPS output switch 5 Battery fuses switch 4 3 1 INPUT MAINS switch This switch connects the external power supply line 380 400 VAC to UPS input port 4 3 2 RESERVE INPUT switch This switch connects the reserve line 380 415 VAC to UPS static
117. telesegnalazioni 3 3 3 Check on remote indications outputting in uscita dalla scheda Rel 10 the Relay Card acri 10 Rev Descrizione Data Controllato Realizzato Data Tipodidoc Paginen Pag totali U T PTX 10 10 2003 Approvato DT0342 E00 Attivazione Setup 3 1 UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 3 1 PRIMA ACCENSIONE E VERIFICHE 3 1 1 Istruzioni per la prima accensione del UPS Gli interruttori d accensione dell UPS si trovano sul retro della porta e in condizione di spegni mento si presentano tutti con la leva oriz zontale Prima di attivare UPS verificare che l interrutto re MANUAL BY PASS sia bloccato da un fermo meccanico e eventuale lucchetto di sicurezza Per attivare l UPS azionare gli interruttori come da sequenza descritta nel riquadro sottostante 1 chiudere il sezionatore MAINS INPUT 3 1 INITIAL TURN ON AND CHECKS 3 1 1 UPS Initial turn on instructions The ON OFF switches of the UPS are situated in the rear of the door and when in the OFF condition the levers are all horizontal Before activating the UPS check that the lever of the MANUAL BY PASS switch has been me chanically locked a safety padlock can be even tually used Before activating the UPS operate the switches following the order given below 3 close the MAINS INPUT switch 1 chiu
118. tester 3 3 3 Check on remote indications outputting the Relay Card The M tagblock of the Relay card is provided with cold contacts of the NO NC types concerning the status of the UPS described in the table below when UPS is OFF the NC contacts must show continuity with the relative common lead Terminals Indications UPS faulty N C By pass enabled N O By pass disabled N C 230 VAC mains failure N O common 230 VAC mains presence N C Sufficient battery level N O Vlake sure that the relationship given IS true by measuring with a tester the ohmic continuity between the common lead and the relative contacts 3 10 Attivazione Setup UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 4 USO E MANUTENZIONE Indice 4 1 Descrizione generale 3 4 1 1 Funzionamento 4 4 1 2 Linea di riserva By pass automatico 4 4 1 3 By pass manuale eenean 4 4 2 Il pannello frontale 5 4 2 1 Pulsante MENU 5 4 2 2 PUSanie ESG iii 5 4 2 3 Pulsanti BACK e NEXT 6 4 2 4 Spia NORMAL 7 4 2 5 Spia ALARM i 7 4 2 6 Menu pannello di comando 7 4 3 Quadro elettrico anteriore 14 4 3 1 Interruttore INPUT MAINS 14 4 3 2 Interruttore RESERVE INPUT 14 4 3 3 Interruttore MANUA
119. to per tutti A 5 F A Q How have you to install your UPS Refer to the instructions supplied in the following documents Chapt 2 Installation To install the Battery Cabinet see the document Annex 1 Battery cubicle To install the Transformer Cabinet see the document Annex 2 Transformer Cabinet Personnel required fitters electricians Where to find instructions to place UPS into operations The first time refer to the instructions supplied in the following documents Chapt 3 Setup Personnel required Final test technicians The following times refer to the following Chapt 4 User manual 4 4 Personnel required anyone can do that How to make the UPS maintenance Refer to the instructions supplied in the following documents Chapt 4 7 Routine Maintenance Personnel required anyone can do that The battery is low what to do Refer to the following documents Chapt 2 5 1 Battery recharging Personnel required anyone can do that The personnel should be upgraded on the simplest UPS s commands how to do Have a short training about these two followings FOREWORD Chapt 4 User manual Personnel required anyone can do that Premessa Foreword XI PREMESSA FOREWORD PREMESSA FOREWORD UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 L UPS guasto che fare Consultare le istruzioni fornite nel Cap
120. to 192 192 192 240 eNi Cd Opzione disponibile su richiesta del cliente Carica rapida Piombo vaso aperto In funzione del tipo di batteria eNi Cd Massima corrente di scarica Vdc 320 V carico nominale 163A 215A 267A 260A Temperatura ambiente media Consigliata 25 C Limiti ammessi in funzionamento regolare 0 40 C La SHT POWER si riserva i diritti di modificare i dati del presente documento senza alcun preavviso Pag 5 11 Documento DT0340 Rev 02 21 01 2003 Specifica Tecnica ATLAS 60 120 kVA Inverter Data 60kVA 80kVA 100kVA 120kVA Tensione nominale di ingresso 384 V 384 V 384 V 480V 192celle 192celle 192celle 240celle Variazione ammessa tensione nominale 320 750 Vdc 320 750 Vdc 320 750 Vdc 396 750Vdc Preallarme batteria Regolabile Regolabile Regolabile Regolabile 350V consigliato 350V consigliato 350V consigliato 430V consigliato Massima corrente assorbita c c 163A 215A 267A 260A Corrente nominale erogata 400Vac 87A 115A 144A 174A Rendimento al 100 del carico gt 95 Tensione di uscita 380 400 415Vac selezionabile Distorsione armonica totale uscita econ carico lineare lt 3 econ carico distorcente secondo EN50091 3 lt 7T Possibilit di variazione della tensione 380 415V Angolo di sfasamento fra le tensioni econ carico bilanciato econ carico sbilanciato al 100 Simmetria delle tensioni estatica con carico bilanciato estatica con carico sbilanciato 50 estatica con carico sbilanciato 100 edinamica
121. troniche X Disposal of electronic cards X Smaltimento delle batterie X Disposal Of batteriesS X Smaltimento di ulteriori parti X Disposal of other parts X A 5 10 domande frequenti FAQ XE A3 FAO ur A XI Q OC W 5 LL I lt v 4 LLI LLI DC A IV Premessa Foreword UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 A y PRONTOSOCCORSO Spegnimento in emergenza In caso di emergenza e possibile inter rompere l alimentazione al carico aprendo tutti gli interruttori ubicati nella parte fronta le inferiore dell UPS dietro la porta Persone colpite da scarica elettrica Sezionare l alimentazione oppure utiliz zare un materiale isolante asciutto per proteggersi mentre si sposta l infortunato lontano da qualsiasi conduttore EVITARE DI TOCCARE L INFORTUNA TO CON LE MANI NUDE FINO A CHE QUEST ULTIMO NONSIA LONTANO DA QUALSIASICONDUTTORE CHIEDERE IMMEDIATAMENTE L AIUTO DI UNA PER SONA QUALIFICATA E ADDESTRATA Persone venute in contatto con li quidi corrosivi Qualora l elettrolito delle batterie venisse in contatto con la pelle sciacquare abbon dantemente con acqua la zona di pelle interessata togliere i vestiti contaminati ricoprire le bruciature con garza asciutta Qualora l elettrolito delle batterie venisse in contatto gli occhi lava
122. unta alla scheda rel standard per avere la possibilit di effettuare collegamenti supplementari con un altro PC oppure con un pannello sinottico inoltre dispone di una morsettiera con contatti liberi da tensione che ripete le segnalazioni sullo stato dell UPS ed in grado di pilotare ogni tipo di dispositivo allarmi sonori lampade telesegnalazioni An relay card can be added to a standard relay card to set up additional links with another PC or with a remote panel this card is also provided with a cold contact tagblock which reverts the UPS status indications and controls each type of device acoustic alarms lamps remote indications etc schedarel Relay card INFORMAZIONI GENERALI GENERAL OVERVIEW PANNELLO REMOTO Remote panel Pannello remoto permette di visualizzare a distanza il modo di funzionamento dell UPS ripete gli allarmi con l accensione di LED e l attivazione di un allarme sonoro Viene collegato all UPS attraverso una morsettiera nel quadro elettrico posteriore Remote Panel it remotely displays the operating mode of UPS it reverts the alarms through the lighting up of LEDs and activates a buzzer It is connected to UPS through the tagblock on the rear distribution panel UPS REMOTE MONITOR UPS ON D ON BATTERY LOW BATTERY ON BYPASS O ALARM SILENCE DI POWER CH 1 6 Informazioni general
123. variaz del 50 del carico edinamica variaz del 100 del carico Tempo di ripristino entro i limiti della stabilit statica Corrente di corto circuito Massima variazione della frequenza di Inverter in sincro con rete presente Massima velocit di variazione della frequenza durante il sincronismo 120 1 120 3 lt 1 lt 3 lt 5 lt 3 lt 4 lt 50ms 200 della corrente nominale per lt 5 sec 1 4 selezionabile lt 1Hz s La SHT POWER si riserva i diritti di modificare i dati del presente documento senza alcun preavviso Pag 6 11 Documento DT0340 Rev 02 21 01 2003 Specifica Tecnica ATLAS 60 120 kVA Commutatore Statico 60kVA 80kVA 100kVA 120kVA Tensione nominale ingresso uscita 3ph N 380 400 415Vac Variazione ammessa sulla tensione di ingresso 10 regolabile Sovraccarico 1 5In per 30 minuti 10In per 100ms Tempi massimi di commutazione Inverter Bypass lt 1ms Sovraccarico o comando manuale O ms Bypass Inverter ritorno automatico O ms e A completameto dei dati sopraccitati sono riportate tabelle e grafici riguardanti tutte le gamme La SHT POWER si riserva i diritti di modificare i dati del presente documento senza alcun preavviso Pag 7 11 Documento DT0340 Rev 02 21 01 2003 Specifica Tecnica ATLAS 60 120 kVA NOTA 1 Ingresso esafase incluso filtro passivo Andamento sovraccarico UPS ATLAS in funzione del tempo di applicazione tutte le taglie P
124. wed to turn UPS ON again and to disconnect manual by pass 8 Selezionare il menu COMANDI con le frecce lt 3 o gt 4 e premere ENTER tasti 3 e 4 contemporaneamente per conferma 9 Selezionare INVERTER ON OFF con le frecce lt 3 o gt 4 e premere ENTER tasti 3 e 4 contemporaneamente per conferma 10 Premere ESC per uscire dal menu COMANDI e posizionarsi sul menu segnalazioni e allarmi 4 4 4 Resetting UPS and disconnecting manual by pass without cutting off power to the load UPS is restored back to operation after connect ing the manual by pass switch in the following order 1 close the INPUT RESERVE switch 2 close the INPUT MAINS switch 3 Close external battery isolator and dc fuses 3 4 wait for the front panel switching ON and the LOAD ON BYPASS status verity that the fan will restart 5 Closet he OUTPUT switch 5 6 Open the MANUAL BY PASS switch 7 press the MENU pushbutton 1 8 Choose the COMMAND MODE menu using the anows lt 3 or gt 4 and press ENTER pushbuttons 3 and 4 togheter to confirm 9 Choose INVERTER ON OFF using the arrows lt 3 or gt 4 and press ENTER pushbuttons 3 and 4 togheter to confirm OFF procedure 10 Press CLEAR pushbutton to exit from COMMAND MODE menu to visualize the status and alarm menu 4 18 Uso e manutenzione User manual UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical hand
125. y power supply unit and the signalling interface The battery charger uninterruptedly powers the batteries connecting UPS The battery charger card can recharge up to 80 of the batteries maximum capacity within 12 hours The signalling interface extracts signalling from the control logic and converts them into the protocol specific for the front panel and for the Relay card Likewise the criteria inputting from the front panel automatic by pass forcing and or from the Relay card EPO are forwarded by the signalling interface to the control logic where it will be respectively interpreted i e either switch over to the reserve line and or immediately switch ing off UPS Besides the standard Relay card the signalling interface can also power an optional card one more relay card The auxiliary power unit feeds the Control Logic the front panel and relay cards Informazioni generali General overview 1 9 A INFORMAZIONI GENERALI GENERAL OVERVIEW INFORMAZIONI GENERALI GENERAL OVERVIEW N UPS 60 120kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 1 3 4 Batterie L energia dalle batterie si presenta all ingresso del Convertitore step up del modulo di potenza Quando la rete presente le batterie vengono costantemente ricaricate dal modulo caricabatteria 1 3 5 Scheda Rel La scheda rel esegue le medesime funzioni della scheda standard ma rispetto a
126. zionale 17 2 5 Allacciamento provvisorio per la ricarica delle batterie 18 3 ATTIVAZIONE 3 1 Prima accensione e verifiche 3 3 2 UPIEGISPOSIZIONI svi eiaslioo 7 3 3 Attivazione dei dispositivi periferici 11 dl CONTENTS FOREWORD Ali FISCAG abbia V A 2 Safety requirements VI A 3 Safety instructions IX A 4 Demolition and Sell off X A 5 10 Frequently asked questionsFAQ XI 1 GENERAL OVERVIEW 1 1 UPS general description 5 1 2 Configuration and optional ra EQUIPMENL vvvrrriiiiiii 7 1 3 Operation Eee 8 O 2 INSTALLATION O 21 IMUTOOUGHON ici 3 2 2 UPS connection to mains 8 2 2 3 External devices connection 14 lt 2 4 Relay card optional 17 cc 2 5 Temporary connection to enable LLI battery recharge 18 Fa 3 SETUP 5 3 1 Initial turn on and checks 3 3 2 Setting Options 7 W 3 3 Pheripheral device set up 9 O n Z U T PTX 10 01 2003 DT0342 E00 E00 Indice generale Table of contents INDICE GENERALE CONTENTS UPS 60 120 kVA ATLAS Manuale tecnicoDT0342 ediz 00 Technical handbook DT0342 Issue 00 4