Home
BTR - PA SpA
Contents
1. QUIPAGGIAME ECNICI LAVAGGIO NT BRACCIO GIRE VOLE INOX P CAR WASH S S CEILING BOOM io ER CAR WASH 81 10 12 9810 00 01 09 05 CARATTERISTICHE TECNICHE TECHNICAL SPECIFICATIONS PRESSIONE NOMINALE RATED PRESSURE 180 bar 18 MPa 2600 psi PRESSIONE CONSENTITA PERMISSIBLE PRESSURE 200 bar 20 MPa 2900 psi PORTATA MASSIMA MAX FLOW RATE 40 I min 10 5 USG p m TEMPERATURA MASSIMA MAX WORKING TEMPERATURE 90 C 195 F ANGOLO DI ROTAZIONE ROTATION ANGLE 360 MISURE D INGOMBRO OVERALL DIMENSIONS CODICE CODE QUOTA DIMENSION LB 28 3040 00 1200 47 24 28 3030 00 1600 63 28 3000 00 1750 68 9 28 3020 00 2000 78 74 28 3025 00 2500 98 43 175 6 9 LB __61 4 Si i co A E Y ol bid Zi Si 2 21 180 7 09 Ga A ee oe E SA PIASTRA DI FISSAGGIO CON ATTACCHI DIVERSI gt MO
2. previsti nelle CARATTERISTICHE TECNICHE di questo manuale UTILIZATION This boom is designed to be used with water up to 90 C or 194 F mixed with car wash detergents Before using specific liquids high viscosity very aggressive chemicals or else consult our technical department Make sure the boom is always used within the limits Pressure Temperature as shown in the TECHNICAL SPECIFICATIONS of this Manual F Cad Fascicolo Tecnico Bracci Lib Bracci doc Ultimo aggiornamento Last update 05 10 2005 FUNZIONAMENTO Il Braccio messo in rotazione dall operatore possibile ottenere il ritorno in posizione voluta montando il braccio inclinato di circa 1 5 gradi adottando degli spessori da inserire sotto la piastra di fissaggio OPERATION The boom is moved directly by the user It is possible to mount the boom with an angle of 1 59 by inserting shims between the mounting plate and the wall so that the boom swings back to the required starting position MANUTENZIONE Si consiglia nei periodi dell anno a rischio di gelo a fine lavoro lo svuotamento delle tubazioni del Braccio SERVICING If exposed to freezing temperatures make sure that the boom is completely emptied after use to prevent freeze up AVVERTENZE SULLA SICUREZZA getti d alta pressione possono essere pericolosi se soggetti ad uso non corretto Non dirigere il getto verso persone o apparecchiature elettriche sotto tensione Accertarsi che l impiant
3. er Br A Pos Codice Descrizione Q t K1K2K3 Pos Codice Descrizione Q ta K1K2K3 1 13 5006 00 Nipplo zinc G1 4MM 1 25 7 28 3022 21 Braccio sald 2000 mm inox 2 1 1 2 28 3064 85 Protezione tubo fless 120mm 1 10 7 28 3027 21 Braccio sald 2500 mm inox 3 1 1 3 16 0510 19 Tubo flessib G1 4F 12 1 9m 1 1 1 7 28 3112 21 Braccio sald 1600 mm inox 5 1 1 3 16 0510 20 Tubo flessib G1 4F 12 2 15m 2 1 1 8 28 3005 21 Perno attac soffitto inox 1 1 3 16 0510 25 Tubo flessib G1 4F 12 2 65m 3 1 1 9 28 0364 31 Tappo El Gc1 4 ott 1 10 3 16 0510 13 Tubo flessib G1 4F 12 1 35m 4 1 1 10 28 3001 84 protezione PVC nero 1 10 3 16 0510 17 Tubo flessib G1 4F 12 1 75m 5 1 1 11 11 4439 68 Cuscinetto 40x68x15 mm 2RS1 2 2 4 13 5023 00 Raccordo ad anello Gc3 8M d 12F 1 5 12 28 3002 51 An elast 2 5x36 8 mm inox 1 10 5 26 1200 40 SW25 Giunto gir a sfere G 3 8 MF 1 5 13 28 3004 84 An protezione PVC nero 1 10 6 28 3003 51 Molla terminale 150 mm inox 1 5 14 14 3813 22 Rosetta 13 2x22x1 5 mm allu 2 25 7 28 3012 21 Braccio sald 1750 mm inox 1 1 1 15 26 1300 20 SW90 Giunto gir 90 inox G 1 4 MF 1 5 1 28 3000 00 2 28 3020 00 3 28 3025 00 4 28 3040 00 5 28 3030 00 Aggiornato al 27 11 2015 28 3000 00 BTR 1750 ceiling boom rot single 28 3030 00 BTR 1600 Ceiling boom rot 2 springs 28 3020 00 BTR 2000 ceiling boom rot single 28 3040 00 BTR 1200 Ceiling boom 2 springs 28 3025 00 2500 ceiling
4. 39 0522 623611 ric aut Fax 39 0522 629600 Info pa etl it www pa etl it COMPANY WITH QUALITY SYSTEM CERTIFIED BY DNV GL ISO 9001
5. UNTING PLATE WITH SEVERAL FIXING HOLES 5 100 3 94 gt 150 5 9 160 6 5 AP fi LA AJ Da TOT IT boi de A Nae ah IE SI A a sai FE Er Eu 2 RI i via Ss 25 1 q MEE PA Si Nas Ultimo aggiornamento Last update 05 10 2005 INSTALLAZIONE Al fine di prevenire possibili danni alle persone ed alle cose il Braccio va collegato alla struttura con viti adeguate al tipo di flangiatura adottata utilizzando i fori di diametro 14 usare minimo N 2 viti M12 coppia di serraggio 60 Nm con fori di diametro 12 usare minimo N 4 viti M10 coppia di serraggio 35 Nm Il Braccio fornito corredato di un tappo da Gc1 4 con esagono incassato che ha il compito si chiudere ermeticamente l alimentazione che non si vuole utilizzare avvitare con sigillante idoneo e serrare con coppia di 15 Nm Il circuito di Pressione in genere alimentato da Pompe a pistoni deve essere dotato di tutti gli organi di sicurezza e controllo come Valvole di sicurezza di regolazione etc previsti dalle normative vigenti e tarato con caratteristiche inferiori alle caratteristiche massime indicate dalla scheda tecnica del braccio Per il collegamento utilizzare un tubo flessibile e una pistola d adeguate caratteristiche sezione e resistenza vedi catalogo PA evitando il pi possibile strozzature e bru
6. boom rot single 2 z gt Y gt MO Br 2 Pos P N Description Qty K1K2K3K4 Pos P N Description Qty K1K2K3K4 1 13 5006 00 Nipple z pl 1 4MM Bsp 1 25 7 28 3022 21 Welded boom 2000 mm Sst 2 1 1 2 28 3064 85 Hose protector 120 mm 1 10 7 28 3027 21 Welded boom 2500 mm Sst 3 1 1 3 16 0510 19 Hose 1 4F Bsp 12 1 9m 1 1 1 7 28 3112 21 Welded boom 1600 mm Sst 5 1 1 3 16 0510 20 Hose 1 4F Bsp 12 2 15m 2 1 1 8 28 3005 21 Ceiling mount pin Sst 1 1 3 16 0510 25 Hose 1 4F Bsp 12 2 65m 3 1 1 9 28 0364 31 Plug int hex 1 4 Bspt brass 1 10 3 16 0510 13 Hose 1 4F Bsp 12 1 35m 4 1 1 10 28 3001 84 Guard ring PVC black 1 10 3 16 0510 17 Hose 1 4F Bsp 12 1 75m 5 1 1 11 11 4439 68 Ball bearing 40x68x15 mm 2851 2 2 4 13 5023 00 Ring fitting 3 8M Bspt d 12F 1 5 12 28 3002 51 Snap ring 2 5x36 8 mm Sst 1 10 5 26 1200 40 SW25 Swivel ball bear 3 8 MF Bsp 1 5 13 28 3004 84 Guard ring PVC black 1 10 6 28 3003 51 Front spring 150 mm Sst 1 5 14 14 3813 22 Washer 13 2x22x1 5 mm alu 2 25 7 28 3012 21 Welded boom 1750 mm Sst 1 1 1 15 26 1300 20 SW90 Swivel 90 sst 1 4 MF Bsp 1 5 1 28 3000 00 2 28 3020 00 3 28 3025 00 4 28 3040 00 5 28 3030 00 Last updated 27 11 2015 NOTES NOTES SpA EQUIPAGGIAMENTI TECNICI DEL LAVAGGIO Via Milano 13 42048 Rubiera RE ITALY Tel
7. o di pompaggio sia dotato di una Valvola di sicurezza idonea alle prestazioni richieste Per garantire la sicurezza dell apparecchio usare solamente parti di ricambio originali PA o da lei approvati Condotti per alta pressione giunti e collegamenti sono importanti ai fini della sicurezza dell apparecchio Usate solo condotte giunti e collegamenti correttamente dimensionati e garantiti dal costruttore La ditta costruttrice del Braccio PA non responsabile del montaggio eseguito dall installatore SAFETY INFORMATION Improper use of high pressure jets can be very dangerous Never point jets towards people or electrical appliances Make sure that the pumping system is equipped with a safety valve suitable to working conditions Original PA parts only must be used for repair and servicing to ensure safe operation of the boom High pressure pipes joints and connections are very important for the safety of the equipment Be sure to use only components that are correctly sized and guaranteed by the manufacturer The manufacturer of the boom PA shall not be liable for the installation carried out by the installer F Cad Fascicolo Tecnico Bracci Lib Bracci doc 28 3000 00 1750 Braccio gir singolo 28 3030 00 1600 Braccio girevole 2 molle 28 3020 00 BTR 2000 Braccio gir singolo 28 3040 00 BTR 1200 Braccio girevole 2 molle 28 3025 00 BTR 2500 Braccio gir singolo 4 z gt Y 2
8. sche variazioni di direzione per contenere le cadute di pressione INSTALLATION In order to avoid possible bodily injuries and damages to property the boom must be mounted with fixing screws suitable to the type of flanging chosen when using fixing holes with 14 diameter use at least 2 screws M12 torque setting 60 Nm when using fixing holes with 12 diameter use at least 4 screws M10 torque setting 35Nm The boom is supplied with a Bsp plug with sunk hexagon to hermetically seal one of the two feeding lines that is not used apply a suitable sealant screw in and tighten the plug with a 15 Nm torque setting The pressure circuit normally fed by piston pumps must be equipped with all necessary safety and control devices safety valves pressure regulators etc requested by law for such appliances and must be used within the limits as specified in the Boom Data Sheet For the connection make sure that a flexible hose and a spraying gun with correct capacity and resistance are used see PA catalogue avoiding sharp bends restrictions elbows and variation of flow in order to reduce pressure drop UTILIZZO Il Braccio costruito per funzionare con acqua fino a 90 additivata con detergenti d uso specifico per auto lavaggi In caso di utilizzo con liquidi particolari diversa viscosit forte aggressivit chimica o altro consultare il nostro Ufficio Tecnico Utilizzare il Braccio sempre entro i limiti di Pressione Temperatura